Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Intervalo de año de publicación
1.
Artículo en Español | MEDLINE | ID: mdl-37780953

RESUMEN

Interatrial septal occlusion devices hinder the transseptal approach for atrial fibrillation ablation, making it necessary to have imaging methods that safely guide transseptal puncture, such as intracardiac echocardiography (ICE). We describe the case of a 49-year-old patient with symptomatic paroxysmal atrial fibrillation, refractory to antiarrhythmic drugs, wearing an interatrial septal occlusion device, with a previous unsuccessful ablation attempt. Atrial fibrillation ablation was performed using the Carto V7 3D mapping system, the transseptal puncture was guided by ICE, and the procedure was successful. This case report highlights the importance of multimodality imaging to achieve successful and effective transseptal puncture for atrial fibrillation ablation in patients with interatrial septal occlusion devices.

2.
Artículo en Español | MEDLINE | ID: mdl-37583450

RESUMEN

Objective: To describe the quality of life in patients with idiopathic ventricular arrhythmias treated at the Instituto Nacional Cardiovascular INCOR in Lima -Peru. Materials and methods: . Analytical and cross-sectional study of patients with idiopathic ventricular arrhythmias treated by 3D ablation or antiarrhythmic therapy between July 2017 and December 2019 to whom the SF-36 health questionnaire was applied to assess quality of life related to health. Results: Fifty-two patients with idiopathic ventricular arrhythmias were included (34 underwent 3D ablation, and 18 underwent antiarrhythmic therapy only). The percentage of recurrence (14.7% vs. 50%, p=0.01) and adverse effects (0% vs. 22.2%, p=0.011) were lower in the 3D ablation group compared to the antiarrhythmic group. The mean standardized scores obtained from the Spanish version of the Health Survey SF-36v2, applied to the 3D ablation and antiarrhythmic groups were 85.1 vs 68.4 (p<0.001), respectively. Were found statistically significant differences in 6 of the eight components that evaluate health-related quality of life: physical function (96.0 vs. 76.0, p<0.001), physical role (93.4 vs. 61.1, p<0.001), general health (74.5 vs. 47.4, p<0.001), vitality (69.9 vs 54.7, p=0.008), emotional role (92.2 vs. 77.8, p=0.006) and mental health (73.8 vs. 60, p<0.001). Conclusions: Patients with idiopathic ventricular arrhythmias who underwent 3D ablation have a higher mean standardized score for health-related quality of life.

3.
Arch Peru Cardiol Cir Cardiovasc ; 2(3): 150-158, 2021.
Artículo en Español | MEDLINE | ID: mdl-37727518

RESUMEN

Objective: To describe the initial experience in ablation of cardiac arrhythmias using 3D mapping at the Instituto Nacional Cardiovascular INCOR (Lima, Peru). Methods: A retrospective descriptive study was carried out. During February 2020, data was collected from the medical records of all patients in whom ablation was performed using 3D mapping from July 2017 to December 2019. This procedure was performed in patients with symptomatic arrhythmia refractory to antiarrhythmic therapy. Results: Data were collected from 123 patients (median age: 46 years, 64.2% male), who had a median time of illness of 6 years. Among the arrhythmias treated, 19% had atrial fibrillation, 17.5% atrial tachycardia, 17.5% idiopathic ventricular arrhythmias, 16.6% Wolf Parkinson White syndrome / Atrioventricular reentrant tachycardia, 11.1% ventricular arrhythmias of the His-Purkinje conduction system, 9.5% scar related ventricular tachycardia associated, 6.4% atrial flutter and 2.4% intranodal tachycardia. The median fluoroscopy time was 26 minutes. Ablation was acutely successful in 95.9% of cases, acute complications were observed in 4.8%, and recurrence-free survival during the first year of follow-up was 74%. Conclusions: Our experience in ablation of cardiac arrhythmias using 3D mapping had a high acute success rate, low frequency of complications, and one-year recurrence-free survival of 74 %.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA