Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 219
Filtrar
1.
J Am Heart Assoc ; 13(15): e034086, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39041603

RESUMEN

BACKGROUND: Detailed visualization and precise measurements of aortic valve dimensions are critical for the success of transcatheter aortic valve implantation and for the prevention of complications. Currently, multislice computed tomography is the gold standard for assessment of the aortic annulus and surrounding structures to determine the prosthesis size. New technologies such as virtual reality (VR) not only enable 3-dimensional (3D) visualization with the potential to improve understanding of anatomy and pathology but also allow measurements in 3D. This study aims to investigate the feasibility, accuracy, and reproducibility of VR for the visualization of the aortic valve, the surrounding structures, and its role in preprocedural sizing for transcatheter aortic valve implantation. METHODS AND RESULTS: Based on the preprocedural multislice computed tomography data, 3mensio measurements and 3D visualizations and measurements using VR software were performed retrospectively on 60 consecutive patients who underwent transcatheter aortic valve implantation at our heart center. There were no significant differences but strong correlations between the VR measurements compared with those performed with the 3mensio software. Furthermore, excellent or good intra- and interobserver reliability could be demonstrated for all values. In a structured questionnaire, users reported that VR simplified anatomical understanding, improved 3D comprehension of adjacent structures, and was associated with very good self-perceived depth perception. CONCLUSIONS: The use of VR for preprocedural transcatheter aortic valve implantation sizing is feasible and has precise and reproducible measurements. In addition, 3D visualization improves anatomical understanding and orientation. To evaluate the potential benefits of 3D visualization for planning further cardiovascular interventions, research in this field is needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estudios de Factibilidad , Prótesis Valvulares Cardíacas , Imagenología Tridimensional , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter , Realidad Virtual , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reproducibilidad de los Resultados , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador
2.
Echocardiography ; 41(8): e15888, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39042643

RESUMEN

BACKGROUND: Device-related thrombosis (DRT) is a common finding after left atrial appendage closure (LAAC) and is associated with worse outcomes. As women are underrepresented in clinical studies, further understanding of sex differences in DRT patients is warranted. METHODS AND RESULTS: This sub-analysis from the EUROC-DRT-registry compromises 176 patients with diagnosis of DRT after LAAC. Women, who accounted for 34.7% (61/176) of patients, were older (78.0 ± 6.7 vs. 74.9 ± 9.1 years, p = .06) with lower rates of comorbidities. While DRT was detected significantly later in women (173 ± 267 vs. 127 ± 192 days, p = .01), anticoagulation therapy was escalated similarly, mainly with initiation of novel oral anticoagulant (NOAC), vitamin K antagonist (VKA) or heparin. DRT resolution was achieved in 67.5% (27/40) of women and in 75.0% (54/72) of men (p = .40). In the remaining cases, an intensification/switch of anticoagulation was conducted in 50.% (9/18) of men and in 41.7% (5/12) of women. Final resolution was achieved in 72.5% (29/40) cases in women, and in 81.9% (59/72) cases in men (p = .24). Women were followed-up for a similar time as men (779 ± 520 vs. 908 ± 687 days, p = .51). Kaplan-Meier analysis revealed no difference in mortality rates in women (Hazard Ratio [HR]: 1.73, 95%-Confidence interval [95%-CI]: .68-4.37, p = .25) and no differences in stroke (HR: .83, 95%-CI: .30-2.32, p = .72) within 2 years after LAAC. CONCLUSION: Evaluation of risk factors and outcome revealed no differences between men and women, with DRT in women being diagnosed significantly later. Women should be monitored closely to assess for DRT formation/resolution. Treatment strategies appear to be equally effective.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Trombosis , Humanos , Femenino , Masculino , Apéndice Atrial/cirugía , Anciano , Trombosis/etiología , Fibrilación Atrial/cirugía , Factores Sexuales , Anticoagulantes/uso terapéutico , Factores de Riesgo , Complicaciones Posoperatorias , Dispositivo Oclusor Septal , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Europa (Continente)/epidemiología , Cierre del Apéndice Auricular Izquierdo
3.
Vasa ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017671

RESUMEN

Background: Bifemoral arterial access is common in patients undergoing transcatheter aortic valve implantation (TAVI), with a primary treatment access (TAVI access) and a secondary non-TAVI access. Pseudoaneurysm (PSA) is an important complication of femoral arterial puncture. Major vascular complications after TAVI are well described, but little is known about PSA. Patients and methods: A total of 2063 patients underwent transfemoral TAVI between January 2014 and January 2020. Vascular ultrasound of the common femoral artery was assessed before and after TAVI. We compared patient characteristics, periprocedural risk scores, procedural characteristics, and access site bleeding events according to Valve Academic Research Consortium 3 (VARC-3) criteria, length of stay (LOS), and all-cause mortality at one year between patients with (46) and without (2017) PSA. Results: The incidence of PSA after TAVI was 2.2% (46/2063). All PSA were successfully treated with ultrasound-guided manual compression (UGMC) or thrombin injection (UGTI) without complications. Patients with PSA had lower platelet counts (210×1000/µl vs. 234×1000/µl; p<0.05), more heart failure symptoms on admission (91% vs. 25%; p<0.05), were more often treated with (N)OACs for atrial fibrillation (AF; 54% vs. 38%; p <0.05), and were less often treated with aspirin (35% vs. 51%; p<0.03). Multivariate analysis identified secondary access site (odds ratio [OR] 8.11; p<0.001) and (N)OAC therapy (OR 1.31; p = 0.037) as risk factors for PSA development. PSA is associated with VARC-3 type 1-3 access site bleeding and longer LOS (15.2 ± 11.3 d vs. 11.6 ± 8.9 d; p<0.01), but this did not affect one year mortality (17% vs. 14%; p = 0.53). Conclusions: Pseudoaneurysms are an important complication after TAVI and are associated with access site bleeding and prolonged hospital stay. (N)OAC therapy and secondary access are important risk factors. Pseudoaneurysms can be safely and effectively treated with thrombin injection and do not affect one-year mortality.

4.
Circulation ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38836358

RESUMEN

BACKGROUND: Whether aortic valve stenosis (AS) can adversely affect systemic endothelial function independently of standard modifiable cardiovascular risk factors is unknown. METHODS: We therefore investigated endothelial and cardiac function in an experimental model of AS mice devoid of standard modifiable cardiovascular risk factors and human cohorts with AS scheduled for transcatheter aortic valve replacement. Endothelial function was determined by flow-mediated dilation using ultrasound. Extracellular hemoglobin (eHb) concentrations and NO consumption were determined in blood plasma of mice and humans by ELISA and chemiluminescence. This was complemented by measurements of aortic blood flow using 4-dimensional flow acquisition by magnetic resonance imaging and computational fluid dynamics simulations. The effects of plasma and red blood cell (RBC) suspensions on vascular function were determined in transfer experiments in a murine vasorelaxation bioassay system. RESULTS: In mice, the induction of AS caused systemic endothelial dysfunction. In the presence of normal systolic left ventricular function and mild hypertrophy, the increase in the transvalvular gradient was associated with elevated eryptosis, increased eHb and plasma NO consumption; eHb sequestration by haptoglobin restored endothelial function. Because the aortic valve orifice area in patients with AS decreased, postvalvular mechanical stress in the central ascending aorta increased. This was associated with elevated eHb, circulating RBC-derived microvesicles, eryptotic cells, lower haptoglobin levels without clinically relevant anemia, and consecutive endothelial dysfunction. Transfer experiments demonstrated that reduction of eHb by treatment with haptoglobin or elimination of fluid dynamic stress by transcatheter aortic valve replacement restored endothelial function. In patients with AS and subclinical RBC fragmentation, the remaining circulating RBCs before and after transcatheter aortic valve replacement exhibited intact membrane function, deformability, and resistance to osmotic and hypoxic stress. CONCLUSIONS: AS increases postvalvular swirling blood flow in the central ascending aorta, triggering RBC fragmentation with the accumulation of hemoglobin in the plasma. This increases NO consumption in blood, thereby limiting vascular NO bioavailability. Thus, AS itself promotes systemic endothelial dysfunction independent of other established risk factors. Transcatheter aortic valve replacement is capable of limiting NO scavenging and rescuing endothelial function by realigning postvalvular blood flow to near physiological patterns. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05603520. URL: https://www.clinicaltrials.gov; Unique identifier: NCT01805739.

5.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38795109

RESUMEN

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía de Estrés , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Curva ROC , Función Ventricular Izquierda , Área Bajo la Curva , Volumen Sistólico , Hemodinámica
6.
Front Cardiovasc Med ; 11: 1328906, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38596690

RESUMEN

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures. Methods: Ten patients scheduled for interventional LAA closure were evaluated with MSCT and TEE. Patient-specific 3D printings and VR models were fabricated based on MSCT data. Ten cardiologists then comparatively assessed LAA anatomy and its procedure relevant surrounding structures with all four imaging modalities and rated their procedural utility on a 5-point Likert scale questionnaire (from 1 = strongly agree to 5 = strongly disagree). Results: Device sizing was rated highest in MSCT (MSCT: 1.9 ± 0.8; TEE: 2.6 ± 0.9; 3D printing: 2.5 ± 1.0; VR: 2.5 ± 1.1; p < 0.01); TEE, VR, and 3D printing were superior in the visualization of the Fossa ovalis compared to MSCT (MSCT: 3.3 ± 1.4; TEE: 2.2 ± 1.3; 3D printing: 2.2 ± 1.4; VR: 1.9 ± 1.3; all p < 0.01). The major strength of VR and 3D printing techniques was a superior depth perception (VR: 1.6 ± 0.5; 3D printing: 1.8 ± 0.4; TEE: 2.9 ± 0.7; MSCT: 2.6 ± 0.8; p < 0.01). The visualization of extracardiac structures was rated less accurate in TEE than MSCT (TEE: 2.6 ± 0.9; MSCT: 1.9 ± 0.8, p < 0.01). However, 3D printing and VR insufficiently visualized extracardiac structures in the present study. Conclusion: A true 3D visualization in VR or 3D printing provides an additional value in the evaluation of the LAA for the planning of percutaneous closure. In particular, the superior perception of depth was seen as a strength of a 3D visualization. This may contribute to a better overall understanding of the anatomy. Clinical studies are needed to evaluate whether a more comprehensive understanding through advanced multimodal imaging of patient-specific anatomy using VR may translate into improved procedural outcomes.

7.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38535105

RESUMEN

Due to the complex and variable anatomy of the left atrial appendage, percutaneous left atrial appendage closure (LAAC) can be challenging. In this study, we investigated the impact of fusion imaging (FI) on the LAAC learning curve of two interventionalists. The first interventionalist (IC 1) was initially trained without FI and continued his training with FI. The second interventionalist (IC 2) performed all procedures with FI. We compared the first 36 procedures without FI of IC 1 (group 1) with his next 36 interventions with FI (group 2). Furthermore, group 1 was compared to 36 procedures of IC 2 who directly started his training with FI (group 3). Group 1 demonstrated that the learning curve without FI has a flat course with weak correlations for fluoroscopy time, contrast volume, and procedure time, but not for dose area product. Group 2 with FI showed improvement with a steep course and strong correlations for all four parameters. In group 3, we also saw a steep progression with strong correlations. Furthermore, the mean measurements of the parameters in the groups with FI decreased significantly as an indicator of procedural efficacy. We demonstrated that FI may improve the learning curve of experienced and non-experienced ICs.

8.
Interv Cardiol ; 19: e01, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38464494

RESUMEN

Optimised implantation depth (OID) is crucial to obtain the best haemodynamic and clinical outcome during transcatheter heart valve (THV) deployment. OID ensures a better haemodynamic profile and is associated with a potential reduction in permanent pacemaker implantations, both of which are important during transcatheter aortic valve replacement (TAVR). Apart from patient-related anatomic conditions, many factors, such as THV and wire selection, as well as implantation strategies, can be controlled by the operator and facilitate the implantation process. However, there are only limited data dealing with predictors for OID. Therefore, the aim of this review was to outline factors and tools that might influence the final implantation depth during TAVR procedures, potentially influencing the outcome.

9.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276659

RESUMEN

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

10.
J Invasive Cardiol ; 36(1)2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38224296

RESUMEN

OBJECTIVES: Dynamic Coronary Roadmap (DCR) is a software tool that creates a real-time dynamic coronary artery overlay on fluoroscopic images. The efficacy of DCR in significantly reducing contrast medium use during percutaneous coronary interventions (PCI) has previously been shown. In this study, we aimed to determine if DCR is equally effective irrespective of the performing investigator's experience level. METHODS: In this sub-analysis of a monocentric, open-label, randomized trial, 130 patients with hemodynamic relevant coronary type A and B lesions were randomized and contrast medium use was conducted with (+) or without (-) DCR software. PCI was randomly allocated and performed by an investigator with high (A) or medium (B) experience level. RESULTS: Overall, contrast medium use was significantly reduced by both investigators in the +DCR group, and Investigator B used significantly less contrast medium with the software than Investigator A. The DCR software was not accompanied by increased radiation exposure for the patients or the teams. On the contrary, dose area product was reduced by both investigators, but was significantly reduced by the highly experienced investigator when using DCR. Fluoroscopy time was not different between investigators. Procedural success was 100%. Serious in-hospital adverse events were not observed. One of Investigator A's patients suffered from post-procedural acute kidney injury in the -DCR group. CONCLUSIONS: DCR significantly reduces contrast medium use during PCI irrespective of investigator's experience level.


Asunto(s)
Lesión Renal Aguda , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Diagnóstico por Imagen , Vasos Coronarios , Corazón , Medios de Contraste/efectos adversos
11.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37524838

RESUMEN

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Diseño de Prótesis , Resultado del Tratamiento
12.
Int J Cardiol ; 399: 131690, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38160912

RESUMEN

BACKGROUND: Impella™ is increasingly used in cardiogenic shock. However, thromboembolic and bleeding events are frequent during percutaneous mechanical circulatory support (pMCS). OBJECTIVE: Therefore, we aimed to explore the optimal anticoagulation regime for pMCS to prevent thromboembolism and bleedings. METHODS: This hypothesis-generating multi-center cohort study investigated 170 patients with left-Impella™ support. We (A) compared bleeding/thrombotic events in two centers with therapeutic range (TR-aPTT) activated partial thromboplastin time (60-80s) and (B) compared events of these centers with one center with intermediate range aPTT (40-60s). RESULTS: After matching, there were no differences in patients' characteristics. In centers aiming at TR-aPTT, major bleeding was numerically lower with aPTT <60s within 48 h of left-Impella™ support, versus patients that achieved the aimed aPTT of ≥60s [aPTT ≥60s: 22 (37.3%) vs. aPTT<60s 14 (23.7%); Hazard ratio [HR], 0.62 (95%) CI, 0.28-1.38; p = 0.234]. Major cardiovascular and cerebrovascular adverse events (MACCE) did not differ between groups. In comparison of centers, TR-aPTT strategy showed higher major bleeding rates [TR: 8 (47.1%) vs. intermediate range: 1 (5.9%); HR, 0.06 (95%) CI, 0.01-0.45; p = 0.006]. MACCE were lower in the intermediate range aPTT group as well [TR 12 (70.6%) vs. intermediate range 5 (29.4%) HR, 0.32 (95%) CI, 0.11-0.92; p = 0.034]. CONCLUSION: This pilot analysis showed that lowering UFH-targets in left-Impella™ supported CS patients seems to be a safe and promising strategy for reducing major bleedings without increasing MACCE. This needs to be validated in larger, randomized clinical trials.


Asunto(s)
Heparina , Tromboembolia , Humanos , Anticoagulantes , Choque Cardiogénico/diagnóstico , Estudios de Cohortes , Tiempo de Tromboplastina Parcial , Hemorragia/inducido químicamente , Hemorragia/diagnóstico , Tromboembolia/inducido químicamente , Estudios Retrospectivos
14.
Front Cardiovasc Med ; 10: 1188571, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37727301

RESUMEN

Background and aims: The complex and highly variable three-dimensional anatomy of the left atrial appendage (LAA) makes planning and device sizing for interventional occlusion procedures (LAAC) challenging. Several imaging modalities [e.g. echocardiography, multi-slice computed tomography (MSCT)] are used for this purpose. Virtual reality (VR) is an emerging imaging technique to immerse into a three-dimensional left atrium and appendage, offering unprecedented options of visualization and measurement. This study aimed to investigate the feasibility, accuracy and reproducibility of visualizing the LAA in VR for preprocedural planning of LAAC. Methods and results: Twenty-one patients (79 ± 7 years, 62% male) who underwent LAAC at University Hospital Düsseldorf were included in our study. A dedicated software generated three-dimensional VR models from preprocedural MSCT imaging data. Conventional measurements of LAA dimensions (ostium, landing zone and depth) using a commercially available software were compared to measurements in VR: MSCT and VR ostium min. (r = 0.93), max. (r = 0.80) and mean (r = 0.88, all p < 0.001) diameters as well as landing zone (LZ) min. (r = 0.84), max. (r = 0.86) and mean diameters (r = 0.90, all p < 0.001) showed strong correlations. Three-dimensional orientation was judged superior by physicians in VR compared to MSCT (p < 0.05). Conclusion: Virtual reality visualization of the left atrium and appendage based on MSCT data is feasible and allows precise and reproducible measurements in planning of LAA occlusion procedures with enhanced 3D orientation. Further studies need to explore additional benefits of three-dimensional visualization for operators in preprocedural planning.

15.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37294311

RESUMEN

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Sistema de Registros , Apéndice Atrial/diagnóstico por imagen
17.
Am J Cardiol ; 197: 87-92, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37137798

RESUMEN

Sex-specific thresholds of aortic valve calcification (AVC) correlate with aortic stenosis (AS) and may complement echocardiography to determine AS severity. Importantly, current guideline-recommended thresholds of AVC scores derived by multislice computed tomography do not distinguish between bicuspid and tricuspid aortic valves. The objective of this study was to evaluate the sex-specific differences in the amount of AVC in patients with severe AS and tricuspid (TAV) versus bicuspid (BAV) aortic valve morphologies, retrospectively evaluated by 2 tertiary care institutions. The inclusion criteria comprised patients with severe AS and a left ventricular ejection fraction ≥50% and suitable imaging examinations. The study included 1,450 patients (723 men; 49.9%) with severe AS, including 1,335 patients with TAV (92.1%) and 115 with BAV (17.9%). The calculated Agatston score was higher in BAV patients (men: BAV 4,358 [2,644 to 6,005] AU vs TAV 2,643 [1,727 to 3,794] AU, p <0.01; women: BAV 2,174 [1,330 to 4,378] AU vs TAV 1,703 [964 to 2,534] AU, p <0.01), also when indexed for valve dimensions and body surface area (men: BAV 2,227 [321 to 3,105] AU/m2 vs TAV 1,333 [872 to 1,913] AU/m2, p <0.01; women: BAV 1,326 [782 to 2,148] AU/m2 vs TAV 930 [546 to 1,456] AU/m2, p <0.01). Differences between the BAV- and TAV-derived Agatston score was more prominent in concordant severe AS. In conclusion, sex-specific Agatston scores in severe AS were approximately 1/3 higher in patients with BAV than in patients with TAV for both women and men. Optimal AVC thresholds should be adjusted for BAV, also respecting considerable prognostic implications.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Masculino , Humanos , Femenino , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen
18.
EuroIntervention ; 19(2): e176-e187, 2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37013922

RESUMEN

BACKGROUND: Reducing rates of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is important for achieving the best procedural outcomes. The cusp overlap technique (COT) implements procedural steps including an overlap angulation of the right and left coronary cusp to mitigate this complication. AIMS: We investigated the incidence of PPI and complication rates following the COT compared to the standard three-cusp implantation technique (3CT) in an all-comers cohort. METHODS: A total of 2,209 patients underwent TAVI with the self-expanding Evolut platform from January 2016 to April 2022 at five sites. Baseline, procedural and in-hospital outcome characteristics were compared for both techniques before and after one-to-one propensity score matching. RESULTS: A total of 1,151 patients were implanted using the 3CT and 1,058 using the COT. At discharge, the rates of PPI (17.0 vs 12.3%; p=0.002) and moderate/severe paravalvular regurgitation (4.6% vs 2.4%; p=0.006) were significantly reduced with the COT compared with 3CT within the unmatched cohort. Overall procedural success and complication rates were similar; major bleeding was less common in the COT group (7.0% vs 4.6%; p=0.020). These results remained consistent after propensity score matching. In multivariable logistic regression analysis, right bundle branch block (odds ratio [OR] 7.19, 95% confidence interval [CI]: 5.18-10.0; p<0.001) and diabetes mellitus (OR 1.38, 95% CI: 1.05-1.80; p=0.021) emerged as predictors of PPI, whereas the COT (OR 0.63, 95% CI: 0.49-0.82; p<0.001) was protective. CONCLUSIONS: The introduction of the COT was associated with a significant and relevant reduction of PPI and paravalvular regurgitation rates without an increase in complication rates.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Diseño de Prótesis , Factores de Riesgo
19.
Nat Commun ; 14(1): 2404, 2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37100836

RESUMEN

Antiplatelet medication is standard of care in acute myocardial infarction (AMI). However, it may have obscured beneficial properties of the activated platelet secretome. We identify platelets as major source of a sphingosine-1-phosphate (S1P) burst during AMI, and find its magnitude to favorably associate with cardiovascular mortality and infarct size in STEMI patients over 12 months. Experimentally, administration of supernatant from activated platelets reduces infarct size in murine AMI, which is blunted in platelets deficient for S1P export (Mfsd2b) or production (Sphk1) and in mice deficient for cardiomyocyte S1P receptor 1 (S1P1). Our study reveals an exploitable therapeutic window in antiplatelet therapy in AMI as the GPIIb/IIIa antagonist tirofiban preserves S1P release and cardioprotection, whereas the P2Y12 antagonist cangrelor does not. Here, we report that platelet-mediated intrinsic cardioprotection is an exciting therapeutic paradigm reaching beyond AMI, the benefits of which may need to be considered in all antiplatelet therapies.


Asunto(s)
Plaquetas , Infarto del Miocardio , Humanos , Ratones , Animales , Infarto del Miocardio/tratamiento farmacológico , Esfingosina , Lisofosfolípidos/uso terapéutico , Miocitos Cardíacos
20.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37119968

RESUMEN

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Función Ventricular Izquierda , Volumen Sistólico , Insuficiencia Cardíaca/complicaciones , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Remodelación Ventricular , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA