Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Alzheimers Dis ; 98(1): 187-195, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38393896

RESUMEN

Background: Documentation of preclinical biomarker tests for Alzheimer's disease (AD) in the medical record may expose patients to employment and insurance discrimination risks. There is a gap in research describing clinicians' approaches to documenting biomarker results. Objective: To evaluate discrimination risks faced by patients undergoing biomarker testing for AD through a qualitative analysis of clinician documentation practices. Methods: Semi-structured interviews using hypothetical patient scenarios. The qualitative analysis focused on interviewees' responses related to documentation and disclosure of results. Results: We collected and analyzed 17 interviews with dementia experts; and identified three approaches to documenting biomarkers as: an association with active AD, noninformative, and an increased susceptibility for AD. Those who associated biomarkers with active disease were more likely to favor disclosure to employers and insurers, which could increase discrimination risks. Conclusions: This study demonstrates the variety of documentation and disclosure practices likely to emerge for preclinical AD biomarker tests and highlights a need for guidelines in this area.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Enfermedad de Alzheimer/diagnóstico , Revelación , Biomarcadores
2.
J Cardiothorac Surg ; 18(1): 349, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38037164

RESUMEN

BACKGROUND: Biomechanical effects of transcatheter (TAVR) versus surgical (SAVR) aortic valve interventions on the distal aorta have not been studied. This study utilized global circumferential strain (GCS) to assess post-procedural biomechanics changes in the descending aorta after TAVR versus SAVR. METHODS: Patients undergoing TAVR or SAVR for aortic stenosis were included. Transesophageal (TEE) and transthoracic (TTE) echocardiography short-axis images of the aorta were used to image the descending aorta immediately before and after interventions. Image analysis was performed with two-dimensional speckle tracking echocardiography and dedicated software. Delta GCS was calculated as: post-procedural GCS-pre-procedural GCS. Percentage delta GCS was calculated as: (delta GCS/pre-procedural GCS) × 100. RESULTS: Eighty patients, 40 TAVR (median age 81 y/o, 40% female) and 40 SAVR (median 72 y/o, 30% female) were included. The post-procedure GCS was significantly higher than the pre-procedural GCS in the TAVR (median 10.7 [interquartile range IQR 4.5, 14.6] vs. 17.0 [IQR 6.1, 20.9], p = 0.009) but not in the SAVR group (4.4 [IQR 3.3, 5.3] vs. 4.7 [IQR 3.9, 5.6], p = 0.3). The delta GCS and the percentage delta GCS were both significantly higher in the TAVR versus SAVR group (2.8% [IQR 1.4, 6] vs. 0.15% [IQR - 0.6, 1.5], p < 0.001; and 28.8% [IQR 14.6%, 64.6%] vs. 4.4% [IQR - 10.6%, 5.6%], p = 0.006). Results were consistent after multivariable adjustment for key clinical and hemodynamic characteristics. CONCLUSIONS: After TAVR, there was a significantly larger increase in GCS in the distal aorta compared to SAVR. This may impact descending aortic remodeling and long-term risk of aortic events.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Fenómenos Biomecánicos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
3.
J Cardiothorac Vasc Anesth ; 36(11): 4141-4149, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35965231

RESUMEN

An increasing number of patients on systemic oral anticoagulants present for cardiac surgery, and cardiac anesthesiologists should be well-informed on their management in the perioperative period. Direct oral anticoagulants (DOACs), including factor Xa inhibitors and direct thrombin inhibitors, are an attractive alternative to warfarin due to fewer dietary and drug interactions, less frequent monitoring requirements, and an improved patient adherence. Since the approval of DOACs by the Food and Drug Administration in 2010, the number of patients on these medications only has increased. The guidelines vary on the periprocedural management of DOACs for cardiac surgery. This review evaluated the current evidence for medication cessation before surgery, based on timing as well as plasma drug concentration. The practice recommendations of various monitoring tests and new evolving point-of-care testing are examined herein. The different reversal agents were discussed by the authors for both elective and urgent procedures. The cardiac anesthesiologist needs to be intimately familiar with the management and current best practices of DOACs for safe and appropriate patient care.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Warfarina , Administración Oral , Anticoagulantes , Antitrombinas/uso terapéutico , Inhibidores del Factor Xa , Hemorragia/inducido químicamente , Humanos
5.
Nat Commun ; 12(1): 5594, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-34552072

RESUMEN

Tungsten ditelluride (WTe2) is an atomically layered transition metal dichalcogenide whose physical properties change systematically from monolayer to bilayer and few-layer versions. In this report, we use apertureless scattering-type near-field optical microscopy operating at Terahertz (THz) frequencies and cryogenic temperatures to study the distinct THz range electromagnetic responses of mono-, bi- and trilayer WTe2 in the same multi-terraced micro-crystal. THz nano-images of monolayer terraces uncovered weakly insulating behavior that is consistent with transport measurements. The near-field signal on bilayer regions shows moderate metallicity with negligible temperature dependence. Subdiffractional THz imaging data together with theoretical calculations involving thermally activated carriers favor the semimetal scenario with [Formula: see text] over the semiconductor scenario for bilayer WTe2. Also, we observed clear metallic behavior of the near-field signal on trilayer regions. Our data are consistent with the existence of surface plasmon polaritons in the THz range confined to trilayer terraces in our specimens. Finally, data for microcrystals up to 12 layers thick reveal how the response of a few-layer WTe2 asymptotically approaches the bulk limit.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA