Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Signal Transduct Target Ther ; 8(1): 305, 2023 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-37591843

RESUMEN

Although VEGF-B was discovered as a VEGF-A homolog a long time ago, the angiogenic effect of VEGF-B remains poorly understood with limited and diverse findings from different groups. Notwithstanding, drugs that inhibit VEGF-B together with other VEGF family members are being used to treat patients with various neovascular diseases. It is therefore critical to have a better understanding of the angiogenic effect of VEGF-B and the underlying mechanisms. Using comprehensive in vitro and in vivo methods and models, we reveal here for the first time an unexpected and surprising function of VEGF-B as an endogenous inhibitor of angiogenesis by inhibiting the FGF2/FGFR1 pathway when the latter is abundantly expressed. Mechanistically, we unveil that VEGF-B binds to FGFR1, induces FGFR1/VEGFR1 complex formation, and suppresses FGF2-induced Erk activation, and inhibits FGF2-driven angiogenesis and tumor growth. Our work uncovers a previously unrecognized novel function of VEGF-B in tethering the FGF2/FGFR1 pathway. Given the anti-angiogenic nature of VEGF-B under conditions of high FGF2/FGFR1 levels, caution is warranted when modulating VEGF-B activity to treat neovascular diseases.


Asunto(s)
Factor 2 de Crecimiento de Fibroblastos , Factor B de Crecimiento Endotelial Vascular , Humanos , Factor 2 de Crecimiento de Fibroblastos/genética , Inmunoterapia , Receptor Tipo 1 de Factor de Crecimiento de Fibroblastos/genética
2.
Comput Struct Biotechnol J ; 21: 2405-2418, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37066124

RESUMEN

Platelet-derived growth factor-D (PDGF-D) is abundantly expressed in ocular diseases. Yet, it remains unknown whether and how PDGF-D affects ocular cells or cell-cell interactions in the eye. In this study, using single-cell RNA sequencing (scRNA-seq) and a mouse model of PDGF-D overexpression in retinal pigment epithelial (RPE) cells, we found that PDGF-D overexpression markedly upregulated the key immunoproteasome genes, leading to increased antigen processing/presentation capacity of RPE cells. Also, more than 6.5-fold ligand-receptor pairs were found in the PDGF-D overexpressing RPE-choroid tissues, suggesting markedly increased cell-cell interactions. Moreover, in the PDGF-D-overexpressing tissues, a unique cell population with a transcriptomic profile of both stromal cells and antigen-presenting RPE cells was detected, suggesting PDGF-D-induced epithelial-mesenchymal transition of RPE cells. Importantly, administration of ONX-0914, an immunoproteasome inhibitor, suppressed choroidal neovascularization (CNV) in a mouse CNV model in vivo. Together, we show that overexpression of PDGF-D increased pro-angiogenic immunoproteasome activities, and inhibiting immunoproteasome pathway may have therapeutic value for the treatment of neovascular diseases.

4.
Front Cell Dev Biol ; 9: 686886, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34150781

RESUMEN

Platelet-derived growth factor-D (PDGF-D) is highly expressed in immune cells. However, the potential role of PDGF-D in immune system remains thus far unclear. Here, we reveal a novel function of PDGF-D in activating both classical and alternative complement pathways that markedly increase chemokine and cytokine responses to promote macrophage polarization. Pharmacological targeting of the complement C3a receptor using SB290157 alleviated PDGF-D-induced neuroinflammation by blocking macrophage polarization and inhibited pathological choroidal neovascularization. Our study thus suggests that therapeutic strategies targeting both PDGF-D and the complement system may open up new possibilities for the treatment of neovascular diseases.

5.
Sensors (Basel) ; 16(11)2016 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-27827923

RESUMEN

The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent -CO-NH- amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 10³ cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field.


Asunto(s)
Técnicas Biosensibles/métodos , Resonancia por Plasmón de Superficie/métodos , Ensayo de Inmunoadsorción Enzimática , Escherichia coli O157/fisiología , Inmunoensayo/métodos , Succinimidas
6.
Sensors (Basel) ; 15(8): 20511-23, 2015 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-26295398

RESUMEN

The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a data acquisition circuit board. The data structure, data memory capacity and a line charge-coupled device (CCD) array with a driving circuit for collecting the photoelectric signals are intensively focused on and the high performance analog-to-digital (A/D) converter is comprehensively evaluated. The interface circuit and the photoelectric signal amplifier circuit are first studied to obtain the weak signals from the line CCD array in this experiment. Quantitative measurements for validating the sensitivity of the biosensing system were implemented using ethanol solutions of various concentrations indicated by volume fractions of 5%, 8%, 15%, 20%, 25%, and 30%, respectively, without a biomembrane immobilized on the surface of the SPR sensor. The experiments demonstrated that it is possible to detect a change in the refractive index of an ethanol solution with a sensitivity of 4.99838 × 10(5) ΔRU/RI in terms of the changes in delta response unit with refractive index using this SPR biosensing system, whereby the theoretical limit of detection of 3.3537 × 10(-5) refractive index unit (RIU) and a high linearity at the correlation coefficient of 0.98065. The results obtained from a series of tests confirmed the practicality of this cost-effective portable SPR biosensing system.


Asunto(s)
Electrónica , Resonancia por Plasmón de Superficie/instrumentación , Conversión Analogo-Digital , Calibración , Diseño de Equipo , Etanol/análisis , Procesamiento de Señales Asistido por Computador , Soluciones , Factores de Tiempo
7.
PLoS One ; 10(7): e0132098, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26147997

RESUMEN

Kinetic analysis of biomolecular interactions are powerfully used to quantify the binding kinetic constants for the determination of a complex formed or dissociated within a given time span. Surface plasmon resonance biosensors provide an essential approach in the analysis of the biomolecular interactions including the interaction process of antigen-antibody and receptors-ligand. The binding affinity of the antibody to the antigen (or the receptor to the ligand) reflects the biological activities of the control antibodies (or receptors) and the corresponding immune signal responses in the pathologic process. Moreover, both the association rate and dissociation rate of the receptor to ligand are the substantial parameters for the study of signal transmission between cells. A number of experimental data may lead to complicated real-time curves that do not fit well to the kinetic model. This paper presented an analysis approach of biomolecular interactions established by utilizing the Marquardt algorithm. This algorithm was intensively considered to implement in the homemade bioanalyzer to perform the nonlinear curve-fitting of the association and disassociation process of the receptor to ligand. Compared with the results from the Newton iteration algorithm, it shows that the Marquardt algorithm does not only reduce the dependence of the initial value to avoid the divergence but also can greatly reduce the iterative regression times. The association and dissociation rate constants, ka, kd and the affinity parameters for the biomolecular interaction, KA, KD, were experimentally obtained 6.969×10(5) mL·g(-1)·s(-1), 0.00073 s(-1), 9.5466×10(8) mL·g(-1) and 1.0475×10(-9) g·mL(-1), respectively from the injection of the HBsAg solution with the concentration of 16 ng·mL(-1). The kinetic constants were evaluated distinctly by using the obtained data from the curve-fitting results.


Asunto(s)
Algoritmos , Modelos Químicos , Resonancia por Plasmón de Superficie
8.
PLoS One ; 10(3): e0122005, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25799327

RESUMEN

A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLB-contained solutions of 0 ng · mL(-1), 10 ng · mL(-1), 20 ng · mL(-1), 33.3 ng · mL(-1), and 40 ng · mL(-1) were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng · mL(-1) was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.


Asunto(s)
Técnicas Biosensibles , Clenbuterol , Hígado , Resonancia por Plasmón de Superficie/métodos , Animales , Resonancia por Plasmón de Superficie/instrumentación , Porcinos
9.
PLoS One ; 9(10): e111292, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25354302

RESUMEN

A sensitive and label-free analytical approach for the detection of porcine circovirus type 2 (PCV2) instead of PCV2 antibody in serum sample was systematically investigated in this research based on surface plasmon resonance (SPR) with an establishment of special molecular identification membrane. The experimental device for constructing the biosensing analyzer is composed of an integrated biosensor, a home-made microfluidic module, and an electrical control circuit incorporated with a photoelectric converter. In order to detect the PCV2 using the surface plasmon resonance immunoassay, the mercaptopropionic acid has been used to bind the Au film in advance through the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. PCV2 antibodies were bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. For the purpose of evaluating the performance of this approach, the known concentrations of PCV2 Cap protein of 10 µg/mL, 7.5 µg/mL, 5 µg/mL, 2.5 µg/mL, 1 µg/mL, and 0.5 µg/mL were prepared by diluting with PBS successively and then the delta response units (ΔRUs) were measured individually. Using the data collected from the linear CCD array, the ΔRUs gave a linear response over a wide concentration range of standard known concentrations of PCV2 Cap protein with the R-Squared value of 0.99625. The theoretical limit of detection was calculated to be 0.04 µg/mL for the surface plasmon resonance biosensing approach. Correspondingly, the recovery rate ranged from 81.0% to 89.3% was obtained. In contrast to the PCV2 detection kits, this surface plasmon resonance biosensing system was validated through linearity, precision and recovery, which demonstrated that the surface plasmon resonance immunoassay is reliable and robust. It was concluded that the detection method which is associated with biomembrane properties is expected to contribute much to determine the PCV2 in sample solutions instead of PCV2 antibody in serum samples quantitatively.


Asunto(s)
Técnicas Biosensibles/métodos , Proteínas de la Cápside/química , Circovirus/aislamiento & purificación , Resonancia por Plasmón de Superficie/métodos , Animales , Técnicas Biosensibles/instrumentación , Circovirus/química , Microfluídica/instrumentación , Microfluídica/métodos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA