Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38460161

RESUMEN

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Asunto(s)
Reestenosis Coronaria , Infarto del Miocardio , Femenino , Humanos , Anciano , Paclitaxel , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents , Resultado del Tratamiento , Muerte
2.
EuroIntervention ; 18(14): 1178-1187, 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36373421

RESUMEN

BACKGROUND: While intravascular imaging guidance during percutaneous coronary intervention (PCI) improves outcomes, routine intravascular imaging usage remains low, in part due to perceived inefficiency and safety concerns.  Aims: The LightLab (LL) Initiative was designed to evaluate whether implementing a standardised optical coherence tomography (OCT) workflow impacts PCI safety metrics and procedural efficiency. METHODS: In this multicentre, prospective, observational study, PCI procedural data were collected over 2 years from 45 physicians at 17 US centres. OCT-guided PCI incorporating the LL workflow (N=264), a structured algorithm using routine pre- and post-PCI OCT imaging, was compared with baseline angiography-only PCI (angio) (N=428). Propensity score analysis identified 207 matched procedures. Outcomes included procedure time, radiation exposure, contrast volume, device utilisation, and treatment strategy. RESULTS: Compared with angiography alone, LL workflow OCT-guided PCI increased the median procedural time by 9 minutes but reduced vessel preparation time (2 min LL workflow vs 3 min angio; p<0.001) and resulted in less unplanned additional treatment (4% LL workflow vs 10% angio; p=0.01). With LL workflow OCT guidance, fewer cineangiography views were needed compared to angiography guidance, leading to decreased radiation exposure (1,133 mGy LL workflow vs 1,269 mGy angio; p=0.02), with no difference in contrast utilisation between groups (p=0.28). Furthermore, LL workflow OCT guidance resulted in fewer predilatation balloons and stents being used, more direct stent placement, and greater stent post-dilatation than angiography-guided PCI. CONCLUSIONS: The incorporation of a standardised pre- and post-PCI OCT imaging workflow improves procedural efficiency and safety metrics, at a cost of a modestly longer procedure time.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Tomografía de Coherencia Óptica/métodos , Angiografía Coronaria/métodos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Flujo de Trabajo , Resultado del Tratamiento , Stents , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Ultrasonografía Intervencional/métodos
3.
Am J Cardiol ; 94(3): 358-60, 2004 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-15276105
4.
J Biol Chem ; 279(20): 21651-7, 2004 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-15007078

RESUMEN

A serine (Ser-700) amino acid rather than an asparagine (Asn-700) at residue 700 of thrombospondin-1 has been linked to an increased risk for development of premature, familial heart attacks. We now have identified both functional and structural differences between the Ser-700 and Asn-700 thrombospondin-1 variants. The Ser-700 variant increased the rate and extent of platelet aggregation and showed increased surface expression on platelets compared with the Asn-700 variant. These differences could be ascribed to an enhanced interaction of the Ser-700 variant with fibrinogen on the platelet surface and are consistent with a prothrombotic phenotype in Ser-700 individuals. The Ser-700 variant thrombospondin-1 was conformationally more labile than the Asn-700 variant as demonstrated by increased susceptibility to proteolytic digestion and enhanced susceptibility to unfolding by denaturants. These data suggest a potential molecular and cellular basis for a genetic risk factor associated with early onset myocardial infarction.


Asunto(s)
Asparagina , Infarto del Miocardio/genética , Polimorfismo de Nucleótido Simple , Serina , Trombospondina 1/genética , Trombospondina 1/metabolismo , Dicroismo Circular , Variación Genética , Humanos , Infarto del Miocardio/epidemiología , Agregación Plaquetaria/genética , Agregación Plaquetaria/fisiología , Factores de Riesgo , Trombospondina 1/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA