1.
IEEE Trans Med Imaging ; 20(10): 1061-71, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11686441

RESUMEN

Magnetic resonance imaging (MRI) offers potential advantages over conventional X-ray techniques for guiding and evaluating intravascular interventions. The development of methods to safely and robustly localize and track devices under MRI guidance is mandatory to enable automatic scan plane adaptation so as to exploit the three-dimensional imaging capabilities of the MRI scanner. With regard to the issue of radiofrequency-induced heating, passive approaches to catheter tracking are inherently safe. These techniques visualize intravascular devices by exploiting the susceptibility artifacts associated with the devices. To promote conspicuity, the devices are equipped with paramagnetic markers. This paper introduces a method to enable automatic localization of devices by its ability to recognize markers in two-dimensional MR images. The method requires a coarse segmentation of the vasculature of interest, and consists of two steps. First, it performs a series of postprocessing operations including calculation of the winding number image and of the Laplacian image to detect marker candidates in the image. Second, the device is localized by matching the detected pattern of candidates to the known distance template of the device markers. Results of an animal experiment and of a clinical application are demonstrated. Validation in phantom experiments shows that the method is able to localize the device in 95% of the cases.


Asunto(s)
Cateterismo/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Angioplastia de Balón/métodos , Animales , Arteria Carótida Común/anatomía & histología , Femenino , Humanos , Porcinos
2.
J Magn Reson Imaging ; 12(4): 599-605, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11042643

RESUMEN

Percutaneous placement of an inferior vena cava filter is a means for long-term prevention of pulmonary thromboembolism. In this study we investigated the magnetic resonance (MR) imaging properties of a Nitinol vena cava filter, in various anatomic and angiographic scans, as well as the feasibility of placing this filter under near real-time, high-resolution MR fluoroscopy. We made use of the passive tracking strategy, with on-line image processing and visualization, both in vitro and in a pig. The artifacts provoked by the metallic filter were such that the position and orientation of the filter were well depicted in all scans. Considerable radiofrequency caging obscured the interior of the filter. Our experiments showed that an MR-guided vena cava filter placement, with sufficient temporal and spatial resolution, is possible. Three-dimensional phase contrast MRA allowed direct evaluation of the filter placement procedure, without the use of contrast agent.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Filtros de Vena Cava , Aleaciones , Animales , Artefactos , Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Porcinos
3.
J Magn Reson Imaging ; 12(4): 623-31, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11042646

RESUMEN

Over the past decade, magnetic resonance (MR) imaging has been developed toward a tool for guiding and evaluating diagnostic and therapeutic interventions. Within the field of vascular MR-guided interventions, MR has potential for providing on-line monitoring of the blood volume flow rate, which is relevant during procedures such as balloon angioplasty and stent placement. We recently reported a hardware and software environment for enabling flow quantification every 8 seconds using nontriggered phase-contrast imaging. In the present study, the objective was to increase temporal resolution further to one evaluation per 4 seconds. We achieve this by lowering spatial resolution to 3 pixels per lumen diameter. The accuracy of the measurements is preserved by applying model-based postprocessing for quantification of the volume flow rate. Phantom and volunteer studies are presented, demonstrating the accuracy of the model-driven approach for the applied short acquisitions. The capabilities of the presented approach are illustrated by the results of several hypercapnia experiments and carotid compression tests performed on healthy volunteers.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Flujo Pulsátil , Radiología Intervencionista , Factores de Tiempo
4.
J Magn Reson Imaging ; 10(5): 845-50, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10548798

RESUMEN

In this paper we describe a hardware and software environment for making available quantitative blood flow data inside and outside the magnetic resonance (MR) scanner room during MR-guided diagnostic and therapeutic interventions. The configuration allows for triggered and nontriggered examinations and provides the interventionalist with updated results within 1 second from data acquisition. The practicality of the setup and its potential for clinical and investigative purposes are demonstrated in vitro and in vivo. J. Magn. Reson. Imaging 1999;10:845-850.


Asunto(s)
Angiografía por Resonancia Magnética , Radiología Intervencionista , Velocidad del Flujo Sanguíneo , Arteria Carótida Interna , Circulación Cerebrovascular , Humanos , Angiografía por Resonancia Magnética/métodos , Persona de Mediana Edad , Monitoreo Fisiológico , Fantasmas de Imagen
5.
Eur Radiol ; 9(8): 1488-95, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10525856

RESUMEN

Three strategies for visualisation of MR-dedicated guidewires and catheters have been proposed, namely active tracking, the technique of locally induced field inhomogeneity and passive susceptibility-based tracking. In this article the pros and cons of these techniques are discussed, including the development of MR-dedicated guidewires and catheters, scan techniques, post-processing tools, and display facilities for MR tracking. Finally, some of the results obtained with MR tracking are discussed.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Animales , Artefactos , Cateterismo/instrumentación , Humanos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Radiología Intervencionista , Porcinos
7.
J Magn Reson Imaging ; 8(1): 245-50, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9500288

RESUMEN

The purpose of this study was to demonstrate the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. This was done by investigating the feasibility of MR-guided balloon angioplasty in a stenosed vessel model. Catheters and guidewires were prepared for susceptibility-based MR visualization by incorporating paramagnetic markers into their walls. Near real-time monitoring (up to 1 image/sec) of the interventional procedure was achieved by using a dynamic two-dimensional gradient-echo technique. Devices were localized by on-the-fly subtraction of a baseline image from consecutive dynamic images and by merging the subtraction images with a previously acquired road map. All steps involved in balloon angioplasty, from the introduction and placement of a guidewire to the positioning of a catheter across the stenosis, inflation of the balloon, and dilatation of the stenosis could adequately be monitored with MR fluoroscopy. The beneficial effect of dilatation could be substantiated by a reduction of stenosis-related hypointensities and hyperintensities in the posttreatment MR angiogram as compared to the pretreatment angiogram and by a posttreatment increase of the volumetric flow rate.


Asunto(s)
Angioplastia de Balón/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Constricción Patológica/terapia , Estudios de Factibilidad , Humanos , Modelos Cardiovasculares , Radiología Intervencionista/métodos
8.
IEEE Trans Med Imaging ; 17(5): 779-85, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9874302

RESUMEN

Magnetic resonance imaging (MRI) offers potential advantages over conventional X-ray techniques for guiding and evaluating vascular interventions. Image guidance of such interventions via passive catheter tracking requires real-time image processing. Commercially available MR scanners currently do not provide this functionality. This paper describes an image processing environment that allows near-real-time MR-guided vascular interventions. It demonstrates 1) that flexibility can be achieved by separating the scanner and the image processing/display system, thereby preserving the stability of the scanner and 2) that sufficiently rapid visualization can be achieved by low-cost workstations equipped with graphics hardware. The setup of the hardware and the software is described in detail. Furthermore, image processing techniques are presented for guiding the interventionalist through simple vascular anatomy. Finally, results of a phantom balloon angioplasty experiment are presented.


Asunto(s)
Angioplastia de Balón/métodos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Angioplastia de Balón/instrumentación , Sistemas de Computación , Humanos , Imagen por Resonancia Magnética/instrumentación , Programas Informáticos
9.
IEEE Trans Med Imaging ; 17(5): 831-41, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9874309

RESUMEN

Coil embolization is a safe treatment for cerebral aneurysms only if the width of the neck in relation to the fundus of the aneurysm is small. Therefore, accurate visualization of the aneurysmal neck is required both in the diagnostic process and during the intervention. Conventional digital subtraction angiography (DSA) is still the preferred modality for the examination of cerebrovascular abnormalities like aneurysms, but it often does not provide the required morphological characteristics due to the suboptimal selection of projection angles and resulting overprojections of surrounding vasculature. This paper presents a method for performing a computer-assisted calculation of the optimal projection angles for DSA by post-processing computed tomographic angiography (CTA) volume data using ray-casting techniques and a combination of image processing algorithms. By means of phantom studies, retrospective simulations of angiograms, and in vivo applications of calculated optimal viewing angles, it is demonstrated that the proposed method results in better angiographic projections of the neck of saccular aneurysms with small neck-fundus ratio than those acquired at standard angles prescribed by clinical protocols.


Asunto(s)
Angiografía Cerebral , Embolización Terapéutica , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Radiografía Intervencional , Tomografía Computarizada por Rayos X , Adulto , Embolización Terapéutica/métodos , Femenino , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS