Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 308: 123788, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38142495

RESUMEN

For direct and non-sampling determination of the component concentration of a sample housed in a glass container, an axially slanted illumination (ASI) back-scattering Raman scheme that reduces glass background interference has been demonstrated. The strategy was to increase the distance between the spots illuminated by the laser on the glass container and the housed sample in back-scattering measurement. For realization, the laser initially illuminated at a slant through the upper side of the vial wall (sample-unoccupied space) and reach the top of the sample. By this way, fewer number of generated glass photons could be recognized by a detector since they are farther from the focal plane (sample-illumination spot). The concentration of rosuvastatin (2.98-4.14 wt%) in rosulord samples (mixed with five other excipients) was determined using the ASI back-scattering measurement. When the angle of illumination to the vertical axis was 30° and the distance from the center of the laser spot on the glass wall to the center of spot on the sample (DG-S) was 14.9 mm, the sample peaks became more apparent and characteristic due to the reduced glass background. The accuracy of the concentration measurement was superior to that obtained through conventional back-scattering, in which the DG-S was nearly zero. The proposed scheme provides a simple optical setting to suppress the glass background and takes advantage of the sensitivity of Raman analysis through back-scattering measurement, indicating it as an attractive option for through-container analysis.

2.
Sensors (Basel) ; 23(20)2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37896616

RESUMEN

This paper investigates the performance of a wide variety of radar imaging modes, such as nadir-looking B-scan, or side-looking synthetic aperture radar tomographic acquisitions, performed in both back- and forward-scattering geometries, for the inspection and characterization of roadways. Nadir-looking B-scan corresponds to a low-complexity mode exploiting the direct return from the response, whereas side-looking configurations allow the utilization of angular and polarimetric diversity in order to analyze advanced features. The main objective of this paper is to evaluate the ability of each configuration, independently of aspects related to operational implementation, to discriminate and localize shallow underground defects in the wearing course of roadways, and to estimate key geophysical parameters, such as roughness and dielectric permittivity. Campaign measurements are conducted using short-range radar stepped-frequency continuous-waveform (SFCW) devices operated in the C and X bands, at the pavement fatigue carousel of Université Gustave Eiffel, over debonded areas with artificial defects. The results indicate the great potential of the newly proposed forward-scattering tomographic configuration for detecting slight defects and characterizing roadways. Case studies, performed in the presence of narrow horizontal heterogeneities which cannot be detected using classical B-scan, show that both the coherent integration along an aperture using the back-projection algorithm, and the exploitation of scattering mechanisms specific to the forward-looking bistatic geometry, allows anomalous echoes to be detected and further characterized, confirming the efficacy of radar imaging techniques in such applications.

3.
Life (Basel) ; 12(5)2022 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-35629343

RESUMEN

Understanding protein functions requires not only static but also dynamic structural information. Incoherent quasi-elastic neutron scattering (QENS), which utilizes the highly incoherent scattering ability of hydrogen, is a powerful technique for revealing the dynamics of proteins in deuterium oxide (D2O) buffer solutions. The background scattering of sample cells suitable for aqueous protein solution samples, conducted with a neutron backscattering spectrometer, was evaluated. It was found that the scattering intensity of an aluminum sample cell coated with boehmite using D2O was lower than that of a sample cell coated with regular water (H2O). The D2O-Boehmite coated cell was used for the QENS measurement of a 0.8 wt.% aqueous solution of an intrinsically disordered protein in an intrinsically disordered region of a helicase-associated endonuclease for a fork-structured type of DNA. The cell was inert against aqueous samples at 283-363 K. In addition, meticulous attention to cells with small individual weight differences and the positional reproducibility of the sample cell relative to the spectrometer neutron beam position enabled the accurate subtraction of the scattering profiles of the D2O buffer and the sample container. Consequently, high-quality information on protein dynamics could be extracted from dilute protein solutions.

4.
Sensors (Basel) ; 21(14)2021 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-34300601

RESUMEN

This article presents a 14-bit chipless RFID label which, in addition to classical identification feature, can be used as decimal numeric keypad, allowing the deployment of secure access control applications. A low-cost single layer label comprising 10 RF loop scatterers is used to code information in the frequency domain. In addition, each resonator is associated to a digit in the decimal number system, and the difference in the spectrum caused by the touch event is exploited for the detection of each key pressing. The shape of the resonators has been carefully selected to be both highly resonant and to show high sensitivity to the presence or absence of the human finger. The concept is validated by measurements in an office environment using an FCC compliant low-cost chipless reader and microstrip vivaldi antennas. Simple detection algorithms are proposed for both identification and touch sensing in real environment.


Asunto(s)
Dispositivo de Identificación por Radiofrecuencia , Percepción del Tacto , Algoritmos , Dedos , Humanos , Tacto
5.
Materials (Basel) ; 14(5)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806679

RESUMEN

Additively manufactured tungsten and its alloys have been widely used for plasma facing components (PFCs) in future nuclear fusion reactors. Under the fusion process, PFCs experience a high-temperature exposure, which will ultimately affect the microstructural features, keeping in mind the importance of microstructures. In this study, microhardness and electron backscatter diffraction (EBSD) techniques were used to study the specimens. Vickers hardness method was used to study tungsten under different parameters. EBSD technique was used to study the microstructure and Kikuchi pattern of samples under different orientations. We mainly focused on selective laser melting (SLM) parameters and the effects of these parameters on the results of different techniques used to study the behavior of samples.

6.
Environ Pollut ; 270: 116288, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33352484

RESUMEN

The particle size distribution (PSD) slope (ξ) can indicate the predominant particle size, material composition, and inherent optical properties (IOPs) of inland waters. However, few semi-analytical methods have been proposed for deriving ξ from the surface remote sensing reflectance due to the variable optical state of inland waters. A semi-analytical algorithm was developed for inland waters having a wide range of turbidity and ξ in this study. Application of the proposed model to Ocean and Land Color Instrument (OLCI) imagery of the water body resulted in several important observations: (1) the proposed algorithm (754 nm and 779 nm combination) was capable of retrieving ξ with R2 being 0.72 (p < 0.01, n = 60), and MAPE and RMSE being 4.37% and 0.22 (n = 30) respectively; (2) the ξ in HZL was lower in summer than other seasons during the period considered, this variation was driven by the phenological cycle of algae and the runoff caused by rainfall; (3) the band optimization proposed in this study is important for calculating the particle backscattering slope (η) and deriving ξ because it is feasible for both algae dominant and sediment governed turbid inland lakes. These observations help improve our understanding of the relationship between IOPs and ξ, which are affected by different bio-optic processes and algal phenology in the lake environment.


Asunto(s)
Clorofila , Lagos , Algoritmos , Clorofila/análisis , Monitoreo del Ambiente , Tamaño de la Partícula , Agua/análisis
7.
Materials (Basel) ; 13(19)2020 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-32998230

RESUMEN

The effect of welding speed on microstructure, mechanical properties, and corrosion properties of laser-assisted welded joints of a twinning-induced plasticity (TWIP) steel was investigated by using X-ray diffraction (XRD), scanning electron microscopy (SEM), electron backscattered diffraction (EBSD) analysis, electrochemical test, and micro-area scanning Kelvin probe test (SKP). The results reveal that the welded joints, with a fully austenitic structure, are obtained by laser welding. In addition, the preferred orientation of grains in fusion zone (FZ) increased with the increase of welding speed. Additionally, the coincidence site lattice (CSL) grain boundaries of FZ decreased with increasing welding speed. However, potentiodynamic polarization and SKP results demonstrated that the welding speed of 1.5 m/min renders superior corrosion resistance. It can also be inferred that the corrosion properties of the welded joints are related to the grain size and frequency of CSL grain boundary in FZ.

8.
Sci Total Environ ; 686: 452-467, 2019 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-31185395

RESUMEN

A closure experiment was conducted over Svalbard by comparing Lidar measurements and optical aerosol properties calculated from aerosol vertical profiles measured using a tethered balloon. Arctic Haze was present together with Icelandic dust. Chemical analysis of filter samples, aerosol size distribution and a full set of meteorological parameters were determined at ground. Moreover, scanning electron microscopy coupled with energy-dispersive X-ray (SEM-EDS) data were at disposal showing the presence of several mineralogical phases (i.e., sheet silicates, gypsum, quartz, rutile, hematite). The closure experiment was set up by calculating the backscattering coefficients from tethered balloon data and comparing them with the corresponding lidar profiles. This was preformed in three subsequent steps aimed at determining the importance of a complete aerosol speciation: (i) a simple, columnar refractive index was obtained by the closest Aerosol Robotic Network (AERONET) station, (ii) the role of water-soluble components, elemental carbon and organic matter (EC/OM) was addressed, (iii) the dust composition was included. When considering the AERONET data, or only the ionic water-soluble components and the EC/OM fraction, results showed an underestimation of the backscattering lidar signal up to 76, 53 and 45% (355, 532 and 1064 nm). Instead, when the dust contribution was included, the underestimation disappeared and the vertically-averaged, backscattering coefficients (1.45 ±â€¯0.30, 0.69 ±â€¯0.15 and 0.34 ±â€¯0.08 Mm-1 sr-1, at 355, 532 and 1064 nm) were found in keeping with the lidar ones (1.60 ±â€¯0.22, 0.75 ±â€¯0.16 and 0.31 ±â€¯0.08 Mm-1 sr-1). Final results were characterized by low RMSE (0.36, 0.08 and 0.04 Mm-1 sr-1) and a high linear correlation (R2 of 0.992, 0.992 and 0.994) with slopes close to one (1.368, 0.931 and 0.977, respectively). This work highlighted the importance of all the aerosol components and of the synergy between single particle and bulk chemical analysis for the optical property characterization in the Arctic.

9.
Sensors (Basel) ; 18(9)2018 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-30134569

RESUMEN

Optical fiber tweezers have been gaining prominence in several applications in Biology and Medicine. Due to their outstanding focusing abilities, they are able to trap and manipulate microparticles, including cells, needing any physical contact and with a low degree of invasiveness to the trapped cell. Recently, we proposed a fiber tweezer configuration based on a polymeric micro-lens on the top of a single mode fiber, obtained by a self-guided photopolymerization process. This configuration is able to both trap and identify the target through the analysis of short-term portions of the back-scattered signal. In this paper, we propose a variant of this fabrication method, capable of producing more robust fiber tips, which produce stronger trapping effects on targets by as much as two to ten fold. These novel lenses maintain the capability of distinguish the different classes of trapped particles based on the back-scattered signal. This novel fabrication method consists in the introduction of a multi mode fiber section on the tip of a single mode (SM) fiber. A detailed description of how relevant fabrication parameters such as the length of the multi mode section and the photopolymerization laser power can be tuned for different purposes (e.g., microparticles trapping only, simultaneous trapping and sensing) is also provided, based on both experimental and theoretical evidences.


Asunto(s)
Diseño de Equipo , Pinzas Ópticas , Polímeros , Análisis de la Célula Individual/instrumentación , Análisis de la Célula Individual/métodos , Rayos Láser , Lentes , Fibras Ópticas , Levaduras/citología
10.
Sensors (Basel) ; 18(3)2018 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-29495502

RESUMEN

Recent trends on microbiology point out the urge to develop optical micro-tools with multifunctionalities such as simultaneous manipulation and sensing. Considering that miniaturization has been recognized as one of the most important paradigms of emerging sensing biotechnologies, optical fiber tools, including Optical Fiber Tweezers (OFTs), are suitable candidates for developing multifunctional small sensors for Medicine and Biology. OFTs are flexible and versatile optotools based on fibers with one extremity patterned to form a micro-lens. These are able to focus laser beams and exert forces onto microparticles strong enough (piconewtons) to trap and manipulate them. In this paper, through an exploratory analysis of a 45 features set, including time and frequency-domain parameters of the back-scattered signal of particles trapped by a polymeric lens, we created a novel single feature able to differentiate synthetic particles (PMMA and Polystyrene) from living yeasts cells. This single statistical feature can be useful for the development of label-free hybrid optical fiber sensors with applications in infectious diseases detection or cells sorting. It can also contribute, by revealing the most significant information that can be extracted from the scattered signal, to the development of a simpler method for particles characterization (in terms of composition, heterogeneity degree) than existent technologies.

11.
ACS Appl Mater Interfaces ; 10(11): 9211-9215, 2018 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-29513988

RESUMEN

Graphene is considered as a promising candidate material to replace silicon for the next-generation nanoelectronics because of its superb carrier mobility. To evaluate its thermal dissipation capability as electronic materials, the thermal transport in monolayer graphene was extensively explored over the past decade. However, the supported chemical vapor deposition (CVD) grown monolayer graphene with submicron structures were seldom studied, which is important for practical nanoelectronics. Here we investigate the thermal transport properties in a series of CVD graphene nanomeshes patterned by a hard-template-assisted etching method. The experimental and numerical results uncovered the phonon backscattering at hole boundary (<100 nm neck width) and its substantial contribution to the thermal conductivity reduction.

12.
Ultrason Imaging ; 40(1): 3-14, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28703685

RESUMEN

This paper presents a new method that complements current techniques available in the high-frequency blood imaging field. A comprehensive scattering model was established to determine the feasibility and frequency range of the blood flow imaging of superficial organs and tissues using high-frequency ultrasound. The transmitting and receiving modes and an algorithm were designed to obtain blood flow information based on differentiation between tissues and blood flow. The system was created and tested first with a model that simulates blood flow and was then used on human tissue. A fine-scale image of a blood vessel could be obtained with this system. Moreover, this method can obtain weak blood flow signal using single pulse rather than the traditional pulse-code method and maintains a high resolution that can be matched to high-frequency structural imaging. This study provides a reliable method for further applications related to diagnoses of superficial organs.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Mano/irrigación sanguínea , Procesamiento de Señales Asistido por Computador , Ultrasonografía/métodos , Mano/diagnóstico por imagen , Humanos
13.
Micron ; 103: 53-63, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28972922

RESUMEN

The present case study compares transmission Kikuchi diffraction (TKD) with electron back-scattering diffraction (EBSD) on the same area of an electron transparent cross-section of a twinning induced plasticity steel. While TKD expectedly provides better clarity of internal defect substructures in the band contrast map, EBSD returns orientation data that approaches the quality of the TKD map. This was rationalised by Monte Carlo simulations of the electron energy spreads, which showed that due to the geometry-based compromises associated with adapting a conventional EBSD detector (which is off-axis with respect to the incident electron beam) to TKD, a broadening in the electron energy distribution of the forward-scattered electrons collected on the detector phosphor screen, is unavoidable. In this circumstance, the values of the full-widths at half-maximum of the energy distributions for TKD and EBSD are of the same order. It follows that EBSD on electron transparent cross-sections may be a viable alternative to TKD when: (i) conventional EBSD detectors are adapted to TKD and, (ii) sample microstructures comprise features whose sizes do not mandate the application of TKD.

14.
J Synchrotron Radiat ; 22(2): 461-4, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25723949

RESUMEN

A small active in-vacuum beamstop has been developed to monitor the flux of intense third-generation synchrotron X-ray beams protecting the downstream detector from the direct beam. Standard active beamstops, where a built-in diode directly absorbs the beam, have limitations in size and lifetime. In the present design, a silicon PIN diode detects the photons back-scattered from a cavity in the beamstop. This approach drastically reduces the radiation dose on the diode and thus increases its lifetime. The beamstop with a diameter of 2 mm has been fabricated to meet the requirements for the P12 bioSAXS beamline of EMBL Hamburg at PETRA III (DESY). The beamstop is in regular user operation at the beamline and displays a good response over the range of energies tested (6-20 keV). Further miniaturization of the diode is easily possible as its size is not limited by the PIN diode used.

15.
Ultramicroscopy ; 151: 23-30, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25522869

RESUMEN

We consider theoretically the energy loss of electrons scattered to high angles when assuming that the primary beam can be limited to a single atom. We discuss the possibility of identifying the isotopes of light elements and of extracting information about phonons in this signal. The energy loss is related to the mass of the much heavier nucleus, and is spread out due to atomic vibrations. Importantly, while the width of the broadening is much larger than the energy separation of isotopes, only the shift in the peak positions must be detected if the beam is limited to a single atom. We conclude that the experimental case will be challenging but is not excluded by the physical principles as far as considered here. Moreover, the initial experiments demonstrate that the separation of gold and carbon based on a signal that is related to their mass, rather than their atomic number.

16.
Ultramicroscopy ; 147: 114-32, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25126753

RESUMEN

Using a combination of electron back-scattering diffraction and energy dispersive X-ray spectroscopy data, a segmentation procedure was developed to comprehensively distinguish austenite, martensite, polygonal ferrite, ferrite in granular bainite and bainitic ferrite laths in a thermo-mechanically processed low-Si, high-Al transformation-induced plasticity steel. The efficacy of the ferrite morphologies segmentation procedure was verified by transmission electron microscopy. The variation in carbon content between the ferrite in granular bainite and bainitic ferrite laths was explained on the basis of carbon partitioning during their growth.

17.
Materials (Basel) ; 7(8): 5992-6009, 2014 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-28788173

RESUMEN

A new high strain rate forming process for titanium alloys is presented and named High Pressure Pneumatic Forming (HPPF), which might be applicable to form certain tubular components with irregular cross sections with high efficiency, both with respect to energy cost and time consumption. HPPF experiments were performed on Ti-3Al-2.5V titanium alloy tubes using a square cross-sectional die with a small corner radius. The effects of forming of pressure and temperature on the corner filling were investigated and the thickness distributions after the HPPF processes at various pressure levels are discussed. At the same time, the stress state, strain and strain rate distribution during the HPPF process were numerically analyzed by the finite element method. Microstructure evolution of the formed tubes was also analyzed by using electron back scattering diffraction (EBSD). Because of different stress states, the strain and strain rate are very different at different areas of the tube during the corner filling process, and consequently the microstructure of the formed component is affected to some degree. The results verified that HPPF is a potential technology to form titanium tubular components with complicated geometrical features with high efficiency.

18.
Biomed Opt Express ; 2(9): 2665-78, 2011 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22091448

RESUMEN

A scattering microscope was developed to investigate single cells and biological microstructures by light scattering measurements. The spectrally resolved part of the setup and its validation are shown in detail. The analysis of light scattered by homogenous polystyrene spheres allows the determination of their diameters using Mie theory. The diameters of 150 single polystyrene spheres were determined by the spectrally resolved scattering microscope. In comparison, the same polystyrene suspension stock was investigated by a collimated transmission setup. Mean diameters and standard deviations of the size distribution were evaluated by both methods with a statistical error of less than 1nm. The systematic errors of both devices are in agreement within the measurement accuracy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA