1.
World J Diabetes ; 15(6): 1254-1262, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38983810

RESUMEN

BACKGROUND: The FreeStyle Libre flash glucose monitoring (FGM) system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose. Due to its increased usage in clinics, the number of studies investigating its accuracy has increased. However, its accuracy has not been investigated in highland popu-lations in China. AIM: To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes (T2D) who had migrated within 3 mo from highlands to plains. METHODS: Overall, 68 patients with T2D, selected from those who had recently migrated from highlands to plains (within 3 mo), were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring (CGM) with the FreeStyle Libre FGM system for 14 d. Throughout the study period, fingertip capillary blood glucose was measured daily using the enzyme electrode method (Super GL, China), and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals. Moreover, the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to < 5 min. The accuracy of the FGM system was evaluated according to the CGM guidelines. Subsequently, the factors influencing the mean absolute relative difference (MARD) of this system were analyzed by a multiple linear regression method. RESULTS: Pearson's correlation analysis showed that the fingertip and scanned glucose levels were positively correlated (R = 0.86, P = 0.00). The aggregated MARD of scanned glucose was 14.28 ± 13.40%. Parker's error analysis showed that 99.30% of the data pairs were located in areas A and B. According to the probe wear time of the FreeStyle Libre FGM system, MARD1 d and MARD2-14 d were 16.55% and 14.35%, respectively (t = 1.23, P = 0.22). Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion (LAGE) was < 5.80 mmol/L but negatively correlated with blood glucose when the LAGE was ≥ 5.80 mmol/L. CONCLUSION: The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains. This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains. MARD is mainly influenced by glucose levels and fluctuations, and the accuracy of the system is higher when the blood glucose fluctuation is small. In case of higher blood glucose level fluctuations, deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38885322

RESUMEN

Objective: We analyzed the effect of implementing a flash glucose monitoring (FGM) technology in a public health care system with universal coverage on the rate of severe hypoglycemia requiring urgent care in adults with type 1 diabetes mellitus (T1DM). Methods: Using a comprehensive regional dataset, we extracted emergency care codes with hypoglycemia in individuals with T1DM who initiated the use of FGM in Andalucia, Spain, from January 1, 2020, to December 31, 2021. Severe hypoglycemia was defined as a confirmed blood glucose <70 mg/dL, which required the urgent dispatch of an emergency medical service (EMS) for onsite management. We compared hypoglycemic events reported in the 12 months before and after the initiation of FGM to determine the population incidence rates. Results: A total of 13,616 participants with a mean age of 43.7 ± 13.5 years were included. The follow-up periods were 23.4 and 24.8 months before and after FGM. There were 969 and 737 cases of hypoglycemia before and after the initiation of FGM. The baseline incidence rate was 358.58 episodes per 10,000 person-years, which decreased to 260.9 at the end of the follow-up (rate-ratio 0.72 [0.66; 0.80]). The reduction in hypoglycemia was significant in individuals aged ≥60 years (rate-ratio 0.40 [0.28; 0.55]) and males (0.64 [0.56; 0.72]). In addition, there was a reduction in the overall median HbA1c of -0.35% (95% CI [-0.38; -0.33], P < 0.001). Conclusion: The implementation of FGM systems in a public health care system as a provision for adults with T1DM was associated with significant reductions in the rate of severe hypoglycemic events that required urgent EMS care.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38885325

RESUMEN

Objective: Glycemic management in people with type 2 diabetes mellitus (T2DM) on insulin-secretagogue regimens without insulin is of importance, as this group still represents a significant proportion of patients. Risks for acute diabetes events (ADEs), including diabetic ketoacidosis (DKA) or hypoglycemia, using insulin-secretagogue drugs are well established. Few studies have suggested that continuous glucose monitoring (CGM) could be useful for monitoring glucose dynamics associated with the use of such therapies. To document this point an exploratory analysis was conducted in a group of individuals with noninsulin treated T2DM in France who are managed with oral insulin-secretagogues and initiating the FreeStyle Libre® system (FSL). Methods: A retrospective study of the French national SNDS reimbursement claims database (≈66 million French people) was conducted to identify people with T2DM on oral insulin-secretagogues and receiving a first reimbursement of FSL between August 1, 2017 and December 31, 2018. The analysis included data for the 12 months before and up to 24 months after FSL initiation. Hospitalizations for diabetes-related acute events were identified using ICD-10 codes as main or related diagnosis, for: hypoglycemic events; DKA events; comas; and hyperglycemia-related admissions. Results: A total of 1272 people with T2DM on insulin-secretagogues without insulin initiated FSL during the selection period. Of these, 7.15% had at least one hospitalization for any ADE in the year before FSL initiation, compared with 2.52% at 12 months and 2.83% at 24 months following FSL initiation. Reductions in ADEs were driven by -73% fewer admissions for ADEs related to diabetic ketoacidosis (DKA) or other hyperglycemia-related events. These patterns of reduced ADEs persisted after 2 years. Conclusions: This study suggests the value of the FSL system in reducing ADEs in some people with T2DM in France being treated with insulin-secretagogues without insulin. Characteristics of these patients remain to be documented.

4.
Front Endocrinol (Lausanne) ; 15: 1374496, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38836229

RESUMEN

Aims: The present study aimed to investigate the accuracy of the Glunovo® real-time continuous glucose monitoring system (rtCGMS). Methods: We conducted a 14-day interstitial glucose level monitoring using Glunovo® rtCGMS on thirty hospitalized patients with type 2 diabetes. The flash glucose monitoring (FGM) was used as a self-control. Consistency tests, error grid analysis, and calculation of the mean absolute relative difference (MARD) were performed using R software to assess the accuracy of Glunovo® rtCGMS. Results: Glunovo® exhibited an overall MARD value of 8.89% during hospitalization, compared to 10.42% for FGM. The overall percentages of glucose values within ±10%/10, ± 15%/15, ± 20%/20, ± 30%/30, and ±40%/40 of the venous blood glucose reference value were 63.34%, 81.31%, 90.50%, 97.29%, and 99.36% for Glunovo®, respectively, compared with 61.58%, 79.63%, 88.31%, 96.22% and 99.23% for FGM. The Clarke Error Grid Analysis showed that 99.61% of Glunovo® glucose pairs and 100.00% of FGM glucose pairs within zones A and B. Conclusion: Our study confirms the superior accuracy of Glunovo® in monitoring blood glucose levels among hospitalized patients with type 2 diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 2 , Hospitalización , Humanos , Diabetes Mellitus Tipo 2/sangre , Femenino , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Masculino , Persona de Mediana Edad , Glucemia/análisis , Estudios Prospectivos , Anciano , Adulto , Monitoreo Continuo de Glucosa
5.
J Diabetes Sci Technol ; : 19322968241246209, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38641969

RESUMEN

BACKGROUND AND AIMS: The Q-Score is a single-number composite metric that is constructed based on the following components: central glycemic tendency, hyperglycemia, hypoglycemia, and intra- and interday variability. Herein, we refined the Q-Score for the screening and analysis of short-term glycemic control using continuous glucose monitoring (CGM) profiles. METHODS: Continuous glucose monitoring profiles were obtained from noninterventional, retrospective cross-sectional studies. The upper limit of the Q-Score component hyperglycemia' that is, the time above target range (TAR), was adjusted from 8.9 to 10 mmol/L (n = 1562 three-day-sensor profiles). A total of 302 people with diabetes mellitus treated with intermittent CGM for ≥14 days were enrolled. The time to stability was determined via correlation-based analysis. RESULTS: There was a strong correlation between the Q-Scores of the two TARs, that is, 8.9 and 10 mmol/L (Q-ScoreTAR10 = -0.03 + 1.00 Q-ScoreTAR8.9, r = .997, p < .001). The times to stability of the Q-Score and TIR were 10 and 12 days, respectively. The Q-Score was correlated with fructosamine concentrations, the glucose management indicator (GMI), the time in range (TIR), and the glycemic risk index (GRI) (r = .698, .887, -.874, and .941), respectively. The number of Q-Score components above the target increased as the TIR decreased, from two (1.7 ± 0.9) in CGM profiles with a TIR between 70% and 80% to four (3.9 ± 0.5) in the majority of the CGM profiles with a TIR below 50%. A conversion matrix between the Q-Score and glycemic indices was developed. CONCLUSIONS: The Q-Score is a tool for assessing short-term glycemic control. The Q-Score can be translated into clinician opinion using the GRI.

6.
J Physiol ; 602(10): 2169-2177, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38680058

RESUMEN

Type 1 diabetes mellitus (T1DM) refers to a metabolic condition where a lack of insulin impairs the usual homeostatic mechanisms to control blood glucose levels. Historically, participation in competitive sport has posed a challenge for those with T1DM, where the dynamic changes in blood glucose during exercise can result in dangerously high (hyperglycaemia) or low blood glucoses (hypoglycaemia) levels. Over the last decade, research and technological development has enhanced the methods of monitoring and managing blood glucose levels, thus reducing the chances of experiencing hyper- or hypoglycaemia during exercise. The introduction of continuous glucose monitoring (CGM) systems means that glucose can be monitored conveniently, without the need for frequent fingerpick glucose checks. CGM devices include a fine sensor inserted under the skin, measuring levels of glucose in the interstitial fluid. Readings can be synchronized to a reader or mobile phone app as often as every 1-5 min. Use of CGM devices is associated with lower HbA1c and a reduction in hypoglycaemic events, promoting overall health and athletic performance. However, there are limitations to CGM, which must be considered when being used by an athlete with T1DM. These limitations can be addressed by individualized education plans, using protective equipment to prevent sensor dislodgement, as well as further research aiming to: (i) account for disparities between CGM and true blood glucose levels during vigorous exercise; (ii) investigate the effects of temperature and altitude on CGM accuracy, and (iii) explore of the sociological impact of CGM use amongst sportspeople without diabetes on those with T1DM.


Asunto(s)
Atletas , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/sangre , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Glucemia/metabolismo , Monitoreo Continuo de Glucosa
7.
Biomed Eng Online ; 23(1): 26, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38419031

RESUMEN

BACKGROUND: Flash glucose monitoring systems like the FreeStyle Libre (FSL) sensor have gained popularity for monitoring glucose levels in people with diabetes mellitus. This sensor can be paired with an off-label converted real-time continuous glucose monitor (c-rtCGM) plus an ad hoc computer/smartphone interface for remote real-time monitoring of diabetic subjects, allowing for trend analysis and alarm generation. OBJECTIVES: This work evaluates the accuracy and agreement between the FSL sensor and the developed c-rtCGM system. As real-time monitoring is the main feature, the system's connectivity was assessed at 5-min intervals during the trials. METHODS: One week of glucose data were collected from 16 type 1 diabetic rats using the FSL sensor and the c-rtCGM. Baseline blood samples were taken the first day before inducing type 1 diabetes with streptozotocin. Once confirmed diabetic rats, FSL and c-rtCGM, were implanted, and to improve data matching between the two monitoring devices, the c-rtCGM was calibrated to the FSL glucometer readings. A factorial design 2 × 3^3 and a second-order regression was used to find the base values of the linear model transformation of the raw data obtained from the sensor. Accuracy, agreement, and connectivity were assessed by median absolute relative difference (Median ARD), range averaging times, Parkes consensus error grid analysis (EGA), and Bland-Altman analysis with a non-parametric approach. RESULTS: Compared to the FSL sensor, the c-rtCGM had an overall Median ARD of 6.58%, with 93.06% of results in zone A when calibration was not carried out. When calibration frequency changed from every 50 h to 1 h, the overall Median ARD improved from 6.68% to 2.41%, respectively. The connectivity evaluation showed that 95% of data was successfully received every 5 min by the computer interface. CONCLUSIONS AND CLINICAL IMPORTANCE: The results demonstrate the feasibility and reliability of real-time and remote subjects with diabetes monitoring using the developed c-rtCGM system. Performing calibrations relative to the FSL readings increases the accuracy of the data displayed at the interface.


Asunto(s)
Diabetes Mellitus Experimental , Diabetes Mellitus Tipo 1 , Humanos , Animales , Ratas , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Reproducibilidad de los Resultados
8.
Curr Diabetes Rev ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38310479

RESUMEN

AIM: The study aimed to compare the effectiveness of oral hypoglycemic agents (OHAs) as monotherapy, dual and quadruple therapy for glycemic control (GC) and glycemic variability (GV) in patients with type-2 diabetes (T2DM) using flash glucose monitoring system (FGM). BACKGROUND: Diabetes management largely relies on HbA1c monitoring. Glycemic variability (GV) has been an evolving glycemic target for preventing complications related to type 2 diabetes mellitus (T2DM). OBJECTIVE: The purpose of the study was to compare glycemic control (GC) measures and glycemic variability (GV) measures among study groups and to study the relationships between GC and GV indices. METHODS: Retrospectively, FGM data were collected from 50 T2DM patients. The patients were classified based on prescribed number of OHAs as monotherapy [group 1: dipeptidyl peptidase- 4 (DPP-4) inhibitors (n=10), group 2: sodium-glucose co-transporter-2 (SGLT2) inhibitors (n=10), group 3: sulphonylureas (n=10), group 4: dual therapy (n=10), and group 5: quadruple therapy (n=10)]. Measures of GC and GV were evaluated. RESULTS: Significant differences between study groups were observed in GC and GV measurements. The SGLT2 inhibitors monotherapy group demonstrated optimal GC [eA1c (%): 6.5 ± 2.2; MBG: 140.80 ± 63.94; TIR: 60.60 ± 19.96] and GV (SD: 42.38 ± 34.57; CV: 27.85 ± 6.68; MAGE: 96.76 ± 52.47; MODD: 33.96 ± 22.91) in comparison to other study groups. On using Pearson correlation analysis, mean blood glucose (MBG) and mean amplitude of glycemic excursion (MAGE) showed moderate correlation (r = 0.742)(r2 = 0.551), depicting distinct glucose variabilities at the same mean blood glucose levels. CONCLUSION: The monotherapy group of SGLT2 inhibitors demonstrated glucose-lowering effects with reduced glycemic variability. Hence, optimum glycemic control is associated with decreased glycemic variability.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38315507

RESUMEN

Objective: To assess the clinical impact of flash glucose monitoring (FGM) systems on fear of hypoglycemia (FoH) and quality of life in adults with type 1 diabetes mellitus (T1DM). Methods: Prospective quasi-experimental study with a 12-month follow-up. People with T1DM (18-80 years old) and self-monitoring by blood capillary glycemia controls were included. The FH15 questionnaire, a survey validated in Spanish in a comparable study population, was used to diagnose FoH with a cutoff point of 28 points. Results: A total of 181 participants were included, with a FoH prevalence of 69% (n = 123). A mean reduction in FH15 score of -4 points (95% confidence interval [-5.5 to -3]; P < 0.001) was observed, along with an improvement in quality of life (EsDQOL-test (Diabetes Quality of Life, Spanish version), -7 points [-10; -4], P < 0.001) and satisfaction with treatment (Diabetes Treatment Satisfaction questionnaire, self-reported version [DTSQ-s] test, +4.5 points [4; 5.5], P < 0.001). At the end of the follow-up, 64.2% of the participants saw an improved FoH intensity, compared to 35.8% who scored the same or higher. This improvement in FoH status was associated with a higher time-in-range at the end of the follow-up (P = 0.003), as well as a lower time spent in hyperglycemia (P = 0.005). In addition, it was linked to participants with a high baseline FoH levels (P < 0.001) and those who were university degree holders (P = 0.07). Conclusions: FGM is associated with an overall reduction of FoH in adults with T1DM and with an increase in their quality of life. Nevertheless, a significant percentage of patients may experience an increase of this phenomenon leading to clinical repercussions and a profound impact on quality of life.

10.
Endocr Pract ; 30(4): 372-379, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38307457

RESUMEN

OBJECTIVE: Christmas holidays can impact weight and glycemic control in type 2 diabetes, but their effect on type 1 diabetes (T1D) remains understudied. This study assessed how Christmas holidays affect individuals with T1D who use flash continuous glucose monitoring systems. METHODS: This retrospective study involved 812 adults diagnosed with T1D recruited from 3 hospitals. Clinical, anthropometric, and socioeconomic data were collected. Glucose metrics from 14 days before January 1st, and before December 1st and February 1st as control periods, were recorded. Analyses adjusted for multiple variables were conducted to assess the holiday season's impact on glycemic control. RESULTS: The average time in range during the holidays (60.0 ± 17.2%) was lower compared to December (61.9 ± 17.2%, P < .001) and February (61.7 ± 17.7%, P < .001). Time above range (TAR > 180 mg/dL) was higher during Christmas (35.8 ± 18.2%) compared to December (34.1 ± 18.3%, P < .001) and February (34.2 ± 18.4%, P < .001). Differences were also observed in TAR >250 mg/dL, coefficient of variation, and average glucose (P < .05). No differences were found in time below range or other metrics. Linear regression models showed that the holidays reduced time in range by 1.9% (ß = -1.92, P = .005) and increased TAR >180 mg/dL by 1.8% (ß = 1.75, P = .016). CONCLUSION: Christmas holidays are associated with a mild and reversible deterioration in glucose metrics among individuals with T1D using flash continuous glucose monitoring, irrespective of additional influencing factors. These discoveries can be useful to advise individuals with diabetes during the festive season and to recognize potential biases within studies conducted during this timeframe.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Humanos , Vacaciones y Feriados , Glucosa , Estudios Retrospectivos , Automonitorización de la Glucosa Sanguínea , Glucemia
11.
J Clin Med ; 13(3)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38337336

RESUMEN

Intermittently Scanned Continuous Glucose Monitoring (isCGM) devices are increasingly being used in patients with type 2 diabetes mellitus (T2DM) on insulin therapy for their benefits regarding disease management. Evidence of isCGM use in patients with T2DM on basal or non-insulin therapy is lacking. This study aimed at assessing the efficacy and safety of isCGM in this population. This was an observational, retrospective, real-world study enrolling patients with T2DM who were starting the use of isCGM. Data from medical records (i.e., demographics, clinical characteristics, laboratory assessments, and isCGM metrics) were collected over three time periods (baseline, 3 and 6 months). The endpoints were glycated haemoglobin (HbA1c) changes and changes in isCGM metrics as defined by the International Consensus from baseline to 3 months and 6 months. Overall, 132 patients were included (69.5% male; mean age 68.2 ± 11.0 years; mean disease duration 19.0 ± 9.4 years; 79.7% on basal insulin ±non-insulin therapy; mean baseline HbA1c 8.1% ± 1.3%). The estimated mean change in HbA1c was statistically significant at three (-0.4 ± 1.0%; p = 0.003) and six months (-0.6 ± 1.3%; p < 0.0001). In conclusion, isCGM proved to be effective and safe in improving glycaemic control in patients with T2DM on basal insulin or non-insulin therapy.

12.
Res Vet Sci ; 169: 105156, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38340380

RESUMEN

Glycemic variability (GV) refers to swings in blood glucose levels and is an emerging measure of glycemic control in clinical practice. It is associated with micro- and macrovascular complications and poor clinical outcomes in diabetic humans. Although an integral part of patient assessment in human patients, it is to a large extent neglected in insulin-treated diabetic dogs. This prospective pilot study was performed to describe canine within-day GV in non-diabetic dogs with the aim to provide a basis for the interpretation of daily glucose profiles, and to promote GV as an accessible tool for future studies in veterinary medicine. Interstitial glucose concentrations of ten non-diabetic, non-obese beagles were continuously measured over a 48-h period using a flash glucose monitoring system. GV was assessed using the common indices MAGE (mean amplitude of glycemic excursion), GVP (Glycemic variability percentage) and CV (coefficient of variation). A total of 2260 sensor measurements were obtained, ranging from 3.7 mmol/L (67 mg/dL) to 8.5 mmol/L (153 mg/dL). Glucose profiles suggested a meal-dependent circadian rhythmicity with small but significant surges during the feeding periods. No differences in GV indices were observed between day and night periods (p > 0.05). The MAGE (mmol/L), GVP (%) and CV (%) were 0.86 (± 0.19), 7.37 (± 1.65), 6.72 (± 0.89) on day one, and 0.83 (± 0.18), 6.95 (± 1.52), 6.72 (± 1.53) on day two, respectively. The results of this study suggest that GV is low in non-diabetic dogs and that glucose concentrations are kept within narrow ranges.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Enfermedades de los Perros , Humanos , Animales , Perros , Glucemia , Automonitorización de la Glucosa Sanguínea/veterinaria , Estudios Prospectivos , Proyectos Piloto , Diabetes Mellitus/veterinaria , Diabetes Mellitus Tipo 2/veterinaria
13.
Diabetol Int ; 15(1): 109-116, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38264231

RESUMEN

Introduction: This study aimed to investigate the association between scan frequency and intermittently scanned continuous glucose monitoring (isCGM) metrics and to clarify the factors affecting scan frequency in adults with type 1 diabetes mellitus (T1D). Methods: We enrolled adults with T1D who used FreeStyle® Libre. Scan and self-monitoring of blood glucose (SMBG) frequency and CGM metrics from the past 90-day glucose data were collected. The receiver operating characteristic curve was plotted to obtain the optimal cutoff values of scan frequency for the target values of time in range (TIR), time above range (TAR), and time below range (TBR). Results: The study was conducted on 211 adults with T1D (mean age, 50.9 ± 15.2 years; male, 40.8%; diabetes duration, 16.4 ± 11.9 years; duration of CGM use, 2.1 ± 1.0 years; and mean HbA1c, 7.6 ± 0.9%). The average scan frequency was 10.5 ± 3.3 scan/day. Scan frequency was positively correlated with TIR and negatively correlated with TAR, although it was not significantly correlated with TBR. Scan frequency was positively correlated with the hypoglycemia fear survey-behavior score, while it was negatively correlated with some glycemic variability metrics. Adult patients with T1D and good exercise habits had a higher scan frequency than those without exercise habits. The AUC for > 70% of the TIR was 0.653, with an optimal cutoff of 11 scan/day. Conclusions: In real-world conditions, frequent scans were linked to improved CGM metrics, including increased TIR, reduced TAR, and some glycemic variability metrics. Exercise habits and hypoglycemia fear-related behavior might affect scan frequency. Our findings could help healthcare professionals use isCGM to support adults with T1D.Clinical Trial Registry No. UMIN000039376.

14.
Metabolites ; 14(1)2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38248850

RESUMEN

During a men's decathlon, a combined event conducted over two consecutive days, fluctuations in blood glucose were measured using flash glucose monitoring. Because decathletes repeatedly intake and exercise, high and low blood glucose levels are observed, but the actual conditions have not yet been clarified. Low blood glucose levels (<80 mg/dL) were observed in nine athletes, while high blood glucose levels (>139 mg/dL) were observed in all athletes at least once during the competition days. Furthermore, low blood glucose levels were observed in nine athletes at least once during and after intake ("intake" refers to consuming energy-containing food and beverages). Additionally, high blood glucose levels were observed in nine athletes at least once during and after intake. Five athletes had low blood glucose during competing time. It was suggested that even if they had eaten a meal just prior to the competition, their intake was likely insufficient for their energy expenditure. A significant positive correlation was found between the mean blood glucose level and the number of intakes on competition days. It is believed that meals may have had a strong influence on blood glucose, even on competition days with a high frequency of eating and exercise for the decathlon.

15.
Eur J Pediatr ; 183(1): 453-460, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37930397

RESUMEN

To effectively manage type 1 diabetes (T1D) insulin is essential, with dosages based on lifestyle. The Mediterranean diet has demonstrated its advantages in preventing and enhancing the management of chronic diseases. Our objective was to investigate the potential mediation of sensor activity on the relationship between adherence to the Mediterranean diet and glycemic control in children and adolescents. A total of 150 children and adolescents (mean age = 13.09, SD = 3.54; 44% female) with T1D were recruited. Adherence to the Mediterranean diet was assessed using the KIDMED questionnaire which evaluates 16 items and gives higher scores when adherence is higher. Glycemic control and the duration of sensor activity were evaluated with data from flash glucose monitoring. The data confirmed our hypothesis by revealing that adherence to the Mediterranean diet positively influenced glycemic control (direct effect = 1.505; P < 0.01) and that this relationship was mediated by the duration of sensor activity (indirect effect = 0.531; P < 0.01).  Conclusions: Our results support the increased utilization of glycemic control devices, as they contribute to improve glycemic control and mediate on the positive relationship between adherence to the Mediterranean diet and adequate glycemic control. Furthermore, our findings highlight the importance of incorporating Mediterranean diet recommendations to achieve better glycemic control in children and adolescents with T1D. What is Known: • The Mediterranean diet and glycemic control have proven benefits in improving cardiovascular health in the general population. Scarce evidence exists of these benefits among children and adolescents with T1D. What is New: • Adherence to the Mediterranean diet and greater use of glucose monitoring devices in children and adolescents with T1D are related to better glycemic control. These variables can be enhanced by psychoeducational interventions such as structured diabetes education programs or peer group-based sessions, which highlights the importance of focusing on these aspects.


Asunto(s)
Diabetes Mellitus Tipo 1 , Dieta Mediterránea , Niño , Humanos , Femenino , Adolescente , Masculino , Diabetes Mellitus Tipo 1/terapia , Automonitorización de la Glucosa Sanguínea , Control Glucémico , Glucemia
16.
Acta Diabetol ; 61(3): 343-350, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37930420

RESUMEN

AIMS: This study aimed to determine the minimum frequency of flash glucose monitoring (FGM) scans necessary for optimal glycemic control in patients with type 1 diabetes (T1D). METHODS: Data were collected from 692 patients (47.5% female, with a median age of 47.4 years) who used FGM systems daily and recorded their clinical variables and device data. RESULTS: Logistic regression models showed that performing more than 12 scans per day was associated with improved T1D control (OR = 4.22, p < 0.001) and a reduction in HbA1c (7.6 vs 7.0%, 60-53 mmol/mol p < 0.001). However, those performing less than 6 scans showed no improvement in HbA1c (7.9 vs 7.8%, 63-61 mmol/mol p = 0.514). Thirteen daily scans were determined as the optimal cutoff point for predicting optimal glycemic control using a maximally selected rank algorithm. Significant reductions were observed in mean glucose (< 0.001), coefficient of variation (< 0.001), HbA1c (< 0.001), and an increase in TIR (< 0.001) in patients who performed more than 12 daily scans. CONCLUSIONS: The results suggest that a higher frequency of daily scans by T1D patients using FGM systems leads to improved chronic glycemic control. The minimum recommended frequency for optimal control is 13 scans per day, and more than 6 daily scans are needed to improve HbA1c.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Femenino , Persona de Mediana Edad , Masculino , Diabetes Mellitus Tipo 1/diagnóstico por imagen , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes , Glucemia , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Control Glucémico , Glucosa
17.
J Clin Endocrinol Metab ; 109(4): 1119-1131, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37987208

RESUMEN

PURPOSE: To provide a systematic review and meta-analysis synthesizing the findings of randomized controlled trials (RCTs) of continuous glucose monitors (CGMs) in the management of adults with type 2 diabetes mellitus (T2DM) on glucose control and clinical outcomes. METHODS: MEDLINE, Embase, and Cochrane were searched for RCTs that assessed the effectiveness of real-time CGM (rt-CGM) or flash CGM (FGM) in adults (≥18 years) with T2DM that reported on at least 1 of the following outcomes: hemoglobin A1c (HbA1c), time in range, time in hyperglycemia, or time in hypoglycemia. The GRADE approach was used to assess certainty of evidence for primary outcomes. RESULTS: Fourteen RCTs assessing CGM were included, with 825 patients in 9 RCTs using rt-CGM and 822 in 5 RCTs using FGM. Moderate certainty of evidence indicated that use of CGM had a modest but statistically significant reduction in HbA1c levels of about 0.32%. Our analyses of each device type separately showed similar reductions in HbA1c (0.34% and 0.33%, respectively, for rt-CGM and FGM), with trends for improvement in other glucose metrics favoring rt-CGM over self-monitored blood glucose. CONCLUSION: Both rt-CGM and flash CGM led to modest but statistically significant declines in HbA1c among individuals with T2DM, with little heterogeneity in the results. However, the duration of the included RCTs was relatively short and few studies reported on important clinical outcomes, such as adverse events, emergency department use, or hospitalization. Longer term studies are needed to determine if the short-term improvements in glucose control leads to improvements in clinically important outcomes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Humanos , Glucemia/análisis , Hemoglobina Glucada , Monitoreo Continuo de Glucosa , Control Glucémico , Automonitorización de la Glucosa Sanguínea/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Hipoglucemiantes/uso terapéutico
18.
BMC Health Serv Res ; 23(1): 1377, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066492

RESUMEN

BACKGROUND: Type 2 diabetes mellitus (T2DM) is highly prevalent within the Indigenous Australian community. Novel glucose monitoring technology offers an accurate approach to glycaemic management, providing real-time information on glucose levels and trends. The acceptability and feasibilility of this technology in Indigenous Australians with T2DM has not been investigated. OBJECTIVE: This feasibility phenomenological study aims to understand the experiences of Indigenous Australians with T2DM using flash glucose monitoring (FGM). METHODS: Indigenous Australians with T2DM receiving injectable therapy (n = 8) who used FGM (Abbott Freestyle Libre) for 6-months, as part of a clinical trial, participated in semi-structured interviews. Thematic analysis of the interviews was performed using NVivo12 Plus qualitative data analysis software (QSR International). RESULTS: Six major themes emerged: 1) FGM was highly acceptable to the individual; 2) FGM's convenience was its biggest benefit; 3) data from FGM was a tool to modify lifestyle choices; 4) FGM needed to be complemented with health professional support; 5) FGM can be a tool to engage communities in diabetes management; and 6) cost of the device is a barrier to future use. CONCLUSIONS: Indigenous Australians with T2DM had positive experiences with FGM. This study highlights future steps to ensure likelihood of FGM is acceptable and effective within the wider Indigenous Australian community.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 2 , Humanos , Australia , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/terapia , Estudios de Factibilidad , Proyectos Piloto , Aborigenas Australianos e Isleños del Estrecho de Torres
19.
J Nephrol ; 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37989976

RESUMEN

Diabetic nephropathy is currently the leading cause of end-stage kidney disease. The present methods of assessing diabetes control, such as glycated hemoglobin or self-monitoring of blood glucose, have limitations. Over the past decade, the field of continuous glucose monitoring has been greatly improved and expanded. This review examines the use of continuous glucose monitoring in people with end-stage kidney disease treated with hemodialysis (HD), peritoneal dialysis (PD), or kidney transplantation. We assessed the use of both real-time continuous glucose monitoring and flash glucose monitoring technology in terms of hypoglycemia detection, glycemic variability, and efficacy, defined as an improvement in clinical outcomes and diabetes control. Overall, the use of continuous glucose monitoring in individuals with end-stage kidney disease may improve glycemic control and detection of hypoglycemia. However, most of the published studies were observational with no control group. Moreover, not all studies used the same assessment parameters. There are very few studies involving subjects on peritoneal dialysis. The small number of studies with limited numbers of participants, short follow-up period, and small number of manufacturers of continuous glucose monitoring systems are limitations of the review. More studies need to be performed to obtain more reliable results.

20.
Diabetes Technol Ther ; 25(12): 836-844, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37902969

RESUMEN

Objective: To describe glucose metrics in a high-risk population of women with type 2 diabetes (T2DM) in pregnancy and to explore the associations with neonatal outcomes. Research Design and Methods: Prospective observational study of 57 women. Continuous glucose monitoring (CGM) trajectories were determined from metrics collected in early and late gestation using the first and last two (mean 16 and 35) weeks of Freestyle Libre data. Logistic regression was used to examine associations of CGM metrics with neonatal hypoglycemia (glucose <2.6 mmol/L requiring intravenous dextrose) and large for gestational age (LGA) (>90th percentile for gestational age and sex). Pregnancy-specific target glucose range was 3.5-7.8 mmol/L (63-140 mg/dL). Results: Forty-one women used CGM for 15 weeks (mean age 33 years, 73% Aboriginal or Torres Strait Islander, 32% living remotely). There was limited change in average metrics from early to late pregnancy. For the subgroup with sensor use >50% (n = 29), mean time in range (TIR) increased by 9%, time above range reduced by 12%, average glucose reduced by 1 mmol/L, and time below range increased by 3%. Neonatal hypoglycemia was associated with most CGM metrics, HbA1c and CGM targets, particularly those from late pregnancy. LGA was associated with hyperglycemic metrics from early pregnancy. Each 1% increase TIR was associated with a 4%-5% reduction in risk of neonatal complications. Conclusion: In this high-risk group of women with T2DM, CGM metrics only improved during pregnancy in those with greater sensor use and were associated with LGA in early pregnancy and neonatal hypoglycemia throughout. Culturally appropriate health care strategies are critical for successful use of CGM technology.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglucemia , Enfermedades del Recién Nacido , Embarazo en Diabéticas , Recién Nacido , Embarazo , Femenino , Humanos , Adulto , Diabetes Mellitus Tipo 2/complicaciones , Glucemia , Mujeres Embarazadas , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Hipoglucemia/prevención & control