Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.709
Filtrar
1.
Expert Rev Med Devices ; : 1-15, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007890

RESUMEN

BACKGROUND: Lumbar spine surgery is a crucial intervention for addressing spinal injuries or conditions affecting the spine, often involving lumbar fusion through pedicle screw (PS) insertion. The precision of PS placement is pivotal in orthopedic surgery. This systematic review compares the accuracy of robot-guided (RG) surgery with free-hand fluoroscopy-guided (FFG), free-hand without fluoroscopy-guided (FHG), and computed tomography image-guided (CTG) techniques for PS insertion. METHODS: A systematic search of various databases from 1 January 2013 to 30 December 2023 was conducted following PRISMA guidelines. Primary outcomes, including PS insertion accuracy and breach rate, were analyzed using a random-effects model. Risk of bias was assessed using the Newcastle-Ottawa Scale. RESULTS: The overall accuracy of PS insertion using RG, based on 37 studies involving 3,837 patients and 22,117 PS, is 97.9%, with a breach rate of 0.021. RG demonstrated superior accuracy compared to FHG and CTG, with breach rates of 3.4 and 0.015 respectively for RG versus FHG, and 3.8 and 0.026 for RG versus CTG. Additionally, RG was associated with reduced mean estimated blood loss compared to CTG, indicating improved safety. CONCLUSIONS: The RG is associated with enhanced accuracy of PS insertion and reduced breach rates over other methods. However, additional randomized controlled trials comparing these modalities are needed for further validation. PROSPERO REGISTRATION: CRD42023483997.

2.
Diagnostics (Basel) ; 14(13)2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-39001334

RESUMEN

We aimed to develop an automated detector that determines laryngeal invasion during swallowing. Laryngeal invasion, which causes significant clinical problems, is defined as two or more points on the penetration-aspiration scale (PAS). We applied two three-dimensional (3D) stream networks for action recognition in videofluoroscopic swallowing study (VFSS) videos. To detect laryngeal invasion (PAS 2 or higher scores) in VFSS videos, we employed two 3D stream networks for action recognition. To establish the robustness of our model, we compared its performance with those of various current image classification-based architectures. The proposed model achieved an accuracy of 92.10%. Precision, recall, and F1 scores for detecting laryngeal invasion (≥PAS 2) in VFSS videos were 0.9470 each. The accuracy of our model in identifying laryngeal invasion surpassed that of other updated image classification models (60.58% for ResNet101, 60.19% for Swin-Transformer, 63.33% for EfficientNet-B2, and 31.17% for HRNet-W32). Our model is the first automated detector of laryngeal invasion in VFSS videos based on video action recognition networks. Considering its high and balanced performance, it may serve as an effective screening tool before clinicians review VFSS videos, ultimately reducing the burden on clinicians.

3.
J Electromyogr Kinesiol ; 78: 102913, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-39004010

RESUMEN

The neurogenic oropharyngeal dysphagia is a prevalent functional swallowing disorder resulting from neurological causes. The conventional diagnosis involves ionizing radiation in Videofluoroscopy Swallowing Studies (VFSS). Surface electromyography (sEMG) offers a non-invasive alternative by recording muscle activity. This research compares bolus passage timing through anatomical structures using VFSS and sEMG-related activation times. Fifty confirmed oropharyngeal dysphagia patients underwent synchronized VFSS and sEMG, evaluating muscle groups during cracker and fluid ingestion. sEMG revealed activation patterns in masseters, suprahyoid, and infrahyoid muscles, occurring before bolus passage through the mandibular line and concluding near the upper esophageal sphincter complex. sEMG identified differences in dysphagia severity (EAT-10 score), age, and diagnosis, contrasting VFSS results. Results indicate potential complementarity between sEMG and VFSS for dysphagia screening, diagnosis, and monitoring.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38950655

RESUMEN

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic, recurrent supraventricular tachycardia (SVT). This study aims to demonstrate if 3D-electroanatomic mapping (EAM) during SVT ablation reduces fluoroscopy time (FT) and determine if further reductions in FT are observed longitudinally. METHODS: All cases of SVT ablation between May 2011-May 2022 at a single tertiary centre were prospectively recruited. FT between the cohorts with and without EAM were compared. Within the EAM subset, the trend of FT across the years was analysed. RESULTS: There were 1758 cases included, 563 without EAM, 1195 with EAM. EAM was associated with a longer procedure time (mean + 8.8 min, p = 0.001), but with mean reductions in FT and dose area product (DAP) by 19.6 min and 18 621 mGy*cm2 respectively (p < 0.001). There was comparable efficacy without any increase in complication rates. Over time (2011-2022), further reduction in FT of 0.9 min year on year was observed (p = 0.001). Between 2011 and 2017, there was a significant reduction in FT of 1.1 min year on year (p = 0.019), which was not observed from 2017 onwards (p = 0.061). The greatest reduction in FT was after the first year of adoption. CONCLUSION: EAM in SVT ablation reduces fluoroscopy use. FT was initially observed to reduce further over time before plateauing, likely due to increased operator experience. While there is increased interest in zero fluoroscopy SVT ablation, complementary use of fluoroscopy may still be necessary in complex cases.

5.
Pain Pract ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951955

RESUMEN

BACKGROUND: Herniated intervertebral disc (HIVD) with radiculopathy is a common degenerative spine disorder. Transforaminal epidural steroid injection (TFESI) is one of the pain relief treatments for lumbar radiculopathy recommended by evidence-based guidelines. Adequate contrast distribution is correlated with better pain control, but the best approach has not been confirmed yet. AIM: To confirm the distribution of contrast medium injected with a new approach of TFESI, that is, far lateral lateral recess approach (FLLR-TFESI). METHODS: Patients receiving TFESI due to HIVD with radiculopathy between 2010 January and 2020 August were retrospectively enrolled. While the FLLR-TFESI was taken as the experimental group, the conventional approach was viewed as the control group. The baseline characteristics, the pattern of contrast enhancement under fluoroscopic guidance, and the complications of these patients were collected and analyzed. RESULTS: A total of 380 patients were analyzed (143 in control group and 237 in experimental group). The two groups were balanced in most baseline characteristics, except disc extrusion (p = 0.01) and scoliosis (p = 0.04). The FLLR-TFESI have a better contrast distribution (p < 0.01), even after adjustment (p < 0.001). No intrathecal injection was noted, but higher rate of intra-disc injection was noted in FLLR-TFESI group (10% vs. 3%, p = 0.008). CONCLUSION: The FLLR-TFESI has a superior contrast enhancement and distribution in comparison to conventional approach. Prospective study to confirm the study result as well as the clinical benefits is suggested in the future.

7.
Curr Cardiol Rep ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995505

RESUMEN

PURPOSE OF THE REVIEW: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF). RECENT FINDINGS: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation. ICE-guided catheter ablation is associated with reduced procedural duration and fluoroscopy use. Recent studies have examined the role of ICE in guiding novel ablation techniques, such as pulsed field ablation. Finally, the use of ICE allows for early detection and timely management of potentially serious procedural complications. Intracardiac echocardiography offers significant advantages during AF ablation procedures and its use should be encouraged to improve procedural safety and efficacy.

8.
Sci Rep ; 14(1): 16332, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009806

RESUMEN

Pulmonary vein isolation (PVI) stands as a widely practiced cardiac ablation procedure on a global scale, conventionally guided by fluoroscopy. The concurrent application of electroanatomical mapping systems (EAMS) and intracardiac echocardiography offers a means to curtail radiation exposure. This study aimed to compare procedural outcomes between conventional and our initial zero-fluoroscopy cases in patients with paroxysmal or persistent atrial fibrillation (AF), undergoing point-by-point PVI. Our prospective observational study included 100 consecutive patients with AF who underwent point-by-point radiofrequency PVI. The standard technique was used in the first 50 cases (Standard group), while the fluoroless technique was used in the subsequent 50 patients (Zero group). The zero-fluoroscopy approach exhibited significantly shorter procedural time (59.6 ± 10.7 min vs. 74.6 ± 13.2 min, p < 0.0001), attributed to a reduced access time (17 [16; 20] min vs. 31 [23; 34.5] min, p < 0.001). Comparable results were found for the number of RF applications, total ablation energy, and left atrial dwelling time. In the Zero group, all procedures were achieved without fluoroscopy, resulting in significantly lower fluoroscopy time (0 [0; 0] sec vs. 132 [100; 160] sec, p < 0.0001) and dose (0 [0; 0] mGy vs. 4.8 [4.1; 8.2] mGy, p < 0.0001). The acute success rate was 100%, with no major complications. Zero-fluoroscopy PVI is feasible, safe, and associated with shorter procedure times compared to the standard approach, even in cases without prior experience in zero-fluoroscopy PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Venas Pulmonares/cirugía , Femenino , Masculino , Fluoroscopía/métodos , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios Prospectivos , Anciano , Resultado del Tratamiento , Ecocardiografía/métodos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38965132

RESUMEN

PURPOSE: Surgical intervention for lateral compression (LC) 1 and 2 pelvic ring fractures is controversial. Posterior ring stabilization remains the most common mode of initial fixation. However, greater mechanical instability is observed in the anterior component of LC pelvic fractures. This study tested whether reduction and percutaneous superior ramus fixation will decrease the instability of LC pelvic fractures on intraoperative fluoroscopic imaging. METHODS: All adult patients (≥ 18 years) presenting with either a Young-Burgess LC1 or LC2 pelvic ring disruption treated operatively with percutaneous anterior followed by posterior fixation by a single surgeon from July 2021 to June 2023 were retrospectively reviewed. Displacement of the anterior ring to intraoperative manual internal rotation stress examination under fluoroscopy was compared before and after anterior pelvic ring reduction and fixation and prior to posterior pelvic ring fixation. Pre- and post-operative visual analog scores (VAS) for pain were also compared. RESULTS: Twenty-one patients with a mean age of 48.7 years were included. Fifteen patients (71.4%) presented with an LC1, and six (28.6%) with an LC2 injury patterns. Anterior pelvic fixation alone provided 7.5mm reduction in mean displacement of the anterior pelvic ring (pre-operative = 9.2 mm vs. post-operative = 1.6 mm, p < 0.001). VAS significantly decreased from 7.2 one-day pre-operatively to 2.2 twenty-four h post-operatively (p < 0.001). CONCLUSIONS: Reduction and fixation of the anterior pelvic ring prior to posterior fixation for LC1 and LC2 pelvic ring disruptions substantially improves mechanical stability on intraoperative stress examination. Combination of percutaneous anterior and posterior fixation significantly decreased VAS above the MCID 24 h after stabilization.

10.
Neurospine ; 21(2): 432-439, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38955520

RESUMEN

OBJECTIVE: Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy. METHODS: SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1-5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body's insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated. RESULTS: The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation. CONCLUSION: The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.

11.
Korean J Pain ; 37(3): 201-210, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946695

RESUMEN

The application of ultrasound (US) in pain medicine has been a rapidly growing field since the 2000s. Musculoskeletal injections, peripheral nerve blocks, and neuraxial injections under US guidance have been acknowledged for managing chronic pain. Although many studies on US-guided pain procedures have been published, there needs to be a classification system to evaluate which image device, the US or fluoroscopy, is clinically and technically better in various pain interventions. Therefore, this narrative review introduces the classification system for the US-guided pain procedures according to their clinical and technical outcomes and designates US-guided pain procedures into one of the four categories by reviewing previous prospective randomized comparative trials.

12.
Korean J Pain ; 37(3): 264-274, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946697

RESUMEN

Background: Radiofrequency ablation is an effective treatment modality in the symptomatic treatment of knee osteoarthritis. Our aim was to compare the efficacy of radiofrequency ablation of the superomedial and inferomedial genicular nerves (2 branches) with the superolateral, superomedial, and inferomedial genicular nerves (3 branches) and to show whether the 2-branch procedure is inferior to the 3-branch procedure. Methods: This study is a prospective, randomized, single-blind clinical study. Eligible participants were randomized into 2 groups: group A, which applied the procedure to the superomedial and inferomedial genicular nerves, and group B, which applied it to the superomedial, superolateral and inferomedial genicular nerves. Pain was evaluated with the numerical rating scale, quality of life with the Short Form-36 (SF-36), and disability with the Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index before, and at 1 and 3 months after the procedure. Results: A total of 41 patients were included. There were no differences between the groups except for the SF-36 physical health sub-score at baseline. A significant improvement was seen in the numeric rating scale (NRS) score, SF-36 sub-scores, WOMAC Index total, as well as pain and physical function scores in both groups, though no significant difference was detected between the groups during follow-up. Conclusions: Although we were unable to establish the noninferiority of conventional radiofrequency ablation (CRFA) applied to 2 branches to CRFA applied to 3 branches, in this trial, significant and similar improvement was observed in NRS, WOMAC total, pain, and physical function and SF-36 scores in both groups.

13.
Korean J Pain ; 37(3): 256-263, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946700

RESUMEN

Background: Cervical epidural block (CEB) is an effective intervention for managing cervical radicular pain. This study aimed to investigate the current status of performing CEB in South Korea. Methods: Pain physicians affiliated with the Korean Pain Society were asked to complete anonymous questionnaires regarding CEB between September and October 2022. The questionnaire consisted of 24 questions assessing the current status and methods of CEB in detail. Results: Of the 198 surveys collected, 171 physicians (86.4%) reported performing CEB. Among those, the majority (94.7%) used fluoroscopy during the procedure. The paramedian interlaminar (IL) approach was the most preferred method (50.3%). Respondents performing fluoroscopic-guided IL CEB were categorized into two groups based on clinical experience: those with ≤10 years of experience (≤10-year group, n = 91) and those with >10 years of experience (>10-year group, n = 71). The proportion of physicians obtaining informed consent in the ≤10-year group and >10-year group was 50.5% and 56.3%, respectively. When entering the epidural space during IL CEB, the contralateral oblique view was the second most frequently used in both groups (≤10-year group, 42.9%; >10-year group, 29.6%). In targeting the upper cervical lesions (C3-4), the proportion of respondents who used an IL space higher than C6-7 was 17.6% in the ≤10-year group and 29.5% in the >10-year experience group. Conclusions: This study demonstrated variability in the CEB technique used by pain physicians in South Korea. The findings highlight the need for education on informed consent and techniques to enhance safety.

14.
Cureus ; 16(6): e61565, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38962582

RESUMEN

Background and objective Trigeminal neuralgia (TN) is a debilitating disorder characterized by acute episodic attacks of pain that significantly impair patients' quality of life and overall functioning. Initial therapeutic strategies to treat this condition include pharmacological options, particularly carbamazepine. In cases with resistance to dose escalation and polypharmacy, interventional procedures may be warranted. The primary aim of this study was to compare the efficacy of trigeminal ganglion (TG) radiofrequency thermocoagulation (RFT) and ultrasound (US)-guided maxillary/mandibular (max/mand) nerve pulsed radiofrequency (PRF) for treating TN, based on the findings at six months post-treatment. The secondary aims were to assess the impact of these interventions on drug consumption and interventional safety based on adverse events. Methods This prospective, randomized, single-blind study was conducted at a single pain clinic. Forty-four patients were randomized into two groups. Group RFT received TG RFT at 60 °C, 65 °C, and 70 °C for 60 seconds each, whereas Group PRF received max/mand PRF for 240 seconds. Pain relief was assessed by using the numeric rating scale (NRS) and intervention effectiveness on medication consumption was evaluated by using the Medication Quantification Scale III (MQS III). The rates of intervention-related adverse events were also compared. Results Both RFT and PRF significantly alleviated pain at one and six months post-treatment compared to baseline (p<0.05). No statistical differences were found in the NRS and MQS III scores between the groups. At six months, 77.3% of RFT patients and 63.9% of PRF patients experienced at least 50% pain relief, with no statistically significant difference. Hypoesthesia occurred in two RFT patients, and masseter weakness was observed in one patient, while no adverse events were reported in the PRF group. Conclusions TG RFT and max/mand PRF are effective treatments for TN. US-guided max/mand PRF, which avoids RFT-associated complications and radiation exposure, may be the superior and preferable option. In this study, the potential space between the coronoid process and maxilla was used to access the maxillary nerve during the maxillary block and PRF procedures, in contrast to the classical approach through the mandibular notch. Further large-scale randomized controlled trials are required to gain deeper insights into the topic.

15.
Arthroplast Today ; 27: 101426, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38952777

RESUMEN

During acetabular cup positioning, intraoperative measurements of cup anteversion were taken using both fluoroscopy and navigation system. With the C-arm introduced at 40°, an anteroposterior view of the pelvis is taken. The C-arm is then centered over the hip, showing an anteverted cup with an approximate inclination of 40°. The axial C-arm is tilted away until the cup opening is visualized as a straight line, indicating that the beam of the fluoroscopy is aligned with the cup's anteversion. The tilt angle on the C-arm and anteversion reading on the navigation workstation were recorded. The high degree of agreement between fluoroscopic and navigation measurement of acetabular cup anteversion supports the use of fluoroscopy in settings with limited access to navigation systems in direct anterior total hip arthroplasty.

16.
Cureus ; 16(5): e61446, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38953067

RESUMEN

BACKGROUND: With recent technological advances, magnetic resonance imaging (MRI) has offered new sequences that can evaluate the real-time motion of anatomic structures. This study aims to evaluate the interobserver agreement in the diagnosis of diaphragmatic dysfunctions using bi-parametric MRI, in which dynamic sequences for diaphragm movement and static sequences for soft tissue resolution are used together to provide a visualization of the diaphragm. METHODOLOGY: Twenty-nine cases that underwent a bi-parametric magnetic resonance examination which includes coronal T2 single-shot turbo spin echo and the coronal SENSE single-shot balanced turbo field echo real-time sequences were retrospectively evaluated. The images of the patients were assessed by two independent observers. Cohen's kappa coefficient was calculated to evaluate the interobserver agreement. RESULTS: The mean age of the patients was 44.86 ± 17.57, ranging from 18 to 80 years. The kappa value was calculated as 0.889, indicating a strong agreement between the interobservers. CONCLUSIONS: Our experience suggests that bi-parametric MRI is a promising tool in the evaluation of diaphragmatic abnormalities.

17.
Artículo en Inglés | MEDLINE | ID: mdl-38963548

RESUMEN

PURPOSE: To describe the methods and outcomes of reamed intramedullary nailing (IMN) of diaphyseal multifragmentary femur (AO/OTA C2 and C3) fractures (DMFFs) in a low-resource setting without fluoroscopy and fracture table. METHODS: The prospective study involved 35 DMFFs among 318 femur fractures treated ≤ 3 weeks post-injury with SIGN nails. The fractures were fixed without fluoroscopy, fracture table and power reaming. Closed, mini-open or open reduction was done. Anatomical length and alignment were ensured using a surgical support triangle during retrograde nailing, and by an assistant during antegrade nailing. Follow-ups were done at 6 weeks, 12 weeks and 6 months. RESULTS: DMFFs constituted 11.0% of the 318 fractures. Twenty-four (68.6%) were males. The mean age was 39.0 years (range 17-75 years). About 94.3% were injured in road traffic accidents. Fracture reduction was closed in 18, mini-open in 8 and full-open in 9. The operative times were significantly shorter for closed than open reduction (p = 0.001). Five fractures received a supplemental fixation with plate or lag screws. By the 12th post-operative week, 97.1% demonstrated continuing radiographic healing, 94.1% tolerated painless weight-bearing and 91.2% could squat & smile. There was no infection or noticeable rotational malunion. Five fractures healed with a limb-length discrepancy of < 2 cm. CONCLUSION: The study demonstrates the feasibility of reamed IMN of DMFFs without fluoroscopy. The outcomes were satisfactory. Although the small sample size and short follow-up period are limitations, the study could serve as a basis for future larger studies in low-resource settings.

18.
Syst Rev ; 13(1): 170, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970142

RESUMEN

BACKGROUND: As an emerging technology in robot-assisted (RA) surgery, the potential benefits of its application in transforaminal lumbar interbody fusion (TLIF) lack substantial support from current evidence. OBJECTIVE: We aimed to investigate whether the RA TLIF is superior to FG TLIF in the treatment of lumbar degenerative disease. METHODS: We systematically reviewed studies comparing RA versus FG TLIF for lumbar degenerative diseases through July 2022 by searching PubMed, Embase, Web of Science, CINAHL (EBSCO), Chinese National Knowledge Infrastructure (CNKI), WanFang, VIP, and the Cochrane Library, as well as the references of published review articles. Both cohort studies (CSs) and randomized controlled trials (RCTs) were included. Evaluation criteria included the accuracy of percutaneous pedicle screw placement, proximal facet joint violation (FJV), radiation exposure, duration of surgery, estimated blood loss (EBL), and surgical revision. Methodological quality was assessed using the Cochrane risk of bias and ROBINS-I Tool. Random-effects models were used, and the standardized mean difference (SMD) was employed as the effect measure. We conducted subgroup analyses based on surgical type, the specific robot system used, and the study design. Two investigators independently screened abstracts and full-text articles, and the certainty of evidence was graded using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. RESULTS: Our search identified 539 articles, of which 21 met the inclusion criteria for quantitative analysis. Meta-analysis revealed that RA had 1.03-folds higher "clinically acceptable" accuracy than FG (RR: 1.0382, 95% CI: 1.0273-1.0493). And RA had 1.12-folds higher "perfect" accuracy than FG group (RR: 1.1167, 95% CI: 1.0726-1.1626). In the case of proximal FJV, our results indicate a 74% reduction in occurrences for patients undergoing RA pedicle screw placement compared to those in the FG group (RR: 0.2606, 95%CI: 0.2063- 0.3293). Seventeen CSs and two RCTs reported the duration of time. The results of CSs suggest that there is no significant difference between RA and FG group (SMD: 0.1111, 95%CI: -0.391-0.6131), but the results of RCTs suggest that the patients who underwent RA-TLIF need more surgery time than FG (SMD: 3.7213, 95%CI: 3.0756-4.3669). Sixteen CSs and two RCTs reported the EBL. The results suggest that the patients who underwent RA pedicle screw placement had fewer EBL than FG group (CSs: SMD: -1.9151, 95%CI: -3.1265-0.7036, RCTs: SMD: -5.9010, 95%CI: -8.7238-3.0782). For radiation exposure, the results of CSs suggest that there is no significant difference in radiation time between RA and FG group (SMD: -0.5256, 95%CI: -1.4357-0.3845), but the patients who underwent RA pedicle screw placement had fewer radiation dose than FG group (SMD: -2.2682, 95%CI: -3.1953-1.3411). And four CSs and one RCT reported the number of revision case. The results of CSs suggest that there is no significant difference in the number of revision case between RA and FG group (RR: 0.4087,95% CI 0.1592-1.0495). Our findings are limited by the residual heterogeneity of the included studies, which may limit the interpretation of the results. CONCLUSION: In TLIF, RA technology exhibits enhanced precision in pedicle screw placement when compared to FG methods. This accuracy contributes to advantages such as the protection of adjacent facet joints and reductions in intraoperative radiation dosage and blood loss. However, the longer preoperative preparation time associated with RA procedures results in comparable surgical duration and radiation time to FG techniques. Presently, FG screw placement remains the predominant approach, with clinical surgeons possessing greater proficiency in its application. Consequently, the integration of RA into TLIF surgery may not be considered the optimal choice. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42023441600.


Asunto(s)
Degeneración del Disco Intervertebral , Vértebras Lumbares , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Robotizados , Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Vértebras Lumbares/cirugía , Fluoroscopía/métodos , Degeneración del Disco Intervertebral/cirugía , Tornillos Pediculares , Tempo Operativo , Estudios de Cohortes
19.
Int J Cardiol ; : 132333, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38972492

RESUMEN

OBJECTIVE: Pregnancy can trigger maternal tachycardias, and the onset of recurrent or incessant focal atrial tachycardia (AT) can lead to tachycardia-induced cardiomyopathy. Medical interventions are commonly employed, but they carry potential fetal and maternal risks. Catheter ablation (CA), particularly with non-fluoroscopic navigation systems, may be considered as an alternative. This systematic review aims to explore the feasibility and outcomes of CA for focal AT during pregnancy. METHODS: A thorough literature search was conducted until September 30th, 2023, on PubMed, Embase, and Cochrane databases. Included articles described maternal focal ATs diagnosed through electrophysiological studies and treated with CA. Data derived from these studies were organized into tables and subsequently analyzed. RESULTS: Out of 278 papers reviewed, 15 articles involving 24 patients were retrieved. CA, utilizing radiofrequency energy achieved acute success in 95.8% of cases. Sixteen patients (66.7%) underwent complete fluoroless procedures, with two adverse events directly related to the procedure reported. Long-term follow-up revealed minimal AT recurrences, with a 0.06% arrhythmia burden in one case. CONCLUSION: Focal ATs during pregnancy can be incessant and refractory to medical intervention, precipitating an acute decline in left ventricular ejection fraction. In this setting, CA emerges as an efficacious treatment modality, particularly in cases of tachycardia-induced cardiomyopathies. Whenever feasible, it is advisable to perform these procedures with minimal or no fluoroscopy guidance. Larger studies are needed to establish the safety and the efficacy of CA for focal ATs during pregnancy, as current research consists of case reports or small case series.

20.
Eur Spine J ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980367

RESUMEN

OBJECTIVE: To compare the differences between Ultrasound Volume Navigation (UVN), O-arm Navigation, and conventional X-ray fluoroscopy-guided screw placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion (MIS-TLIF) surgeries. METHODS: A total of 90 patients who underwent MIS-TLIF due to lumbar disc herniation from January 2022 to January 2023 were randomly assigned to the UVN group, O-arm group, and X-ray group. UVN, O-arm navigation, and X-ray guidance were used for screw placement in the respective groups, while the remaining surgical procedures followed routine MIS-TLIF protocols. Intraoperative data including average single screw placement time, total radiation dose, and average effective radiation dose per screw were recorded and calculated. On the 10th day after surgery, postoperative X-ray and CT examinations were conducted to assess screw placement accuracy and facet joint violation. RESULTS: There were no significant differences in general characteristics among the three groups, ensuring comparability. Firstly, the average single screw placement time in the O-arm group was significantly shorter than that in the UVN group and X-ray group (P<0.05). Secondly, in terms of total radiation dose during surgery, for single-level MIS-TLIF, the O-arm group had a significantly higher radiation dose compared to the UVN group and X-ray group (P<0.05). However, for multi-level MIS-TLIF, the X-ray group had a significantly higher radiation dose than the O-arm group and UVN group (P<0.05). In terms of average single screw radiation dose, the O-arm group and X-ray group were similar (P>0.05), while the UVN group was significantly lower than the other two groups (P<0.05). Furthermore, no significant differences were found in screw placement assessment grades among the three groups (P>0.05). However, in terms of facet joint violation rate, the UVN group (10.3%) and O-arm group (10.7%) showed no significant difference (P>0.05), while the X-ray group (26.7%) was significantly higher than both groups (P<0.05). Moreover, in the UVN group, there were significant correlations between average single screw placement time and placement grade with BMI index (r = 0.637, P<0.05; r = 0.504, P<0.05), while no similar significant correlations were found in the O-arm and X-ray groups. CONCLUSION: UVN-guided screw placement in MIS-TLIF surgeries demonstrates comparable efficiency, visualization, and accuracy to O-arm navigation, while significantly reducing radiation exposure compared to both O-arm navigation and X-ray guidance. However, UVN may be influenced by factors like obesity, limiting its application.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA