Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 409
Filtrar
1.
Cureus ; 16(9): e70561, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39355468

RESUMEN

Pulmonary embolism (PE) occurs when thrombi from deep vein thrombosis dislodge and obstruct pulmonary arteries, raising pulmonary artery pressure and straining the right ventricle. This strain can lead to right ventricular dysfunction (RVD), characterized by reduced cardiac output, impaired contractility, and potential development of chronic thromboembolic pulmonary hypertension. Clinically, PE may present with symptoms such as dyspnea, pleuritic chest pain, and tachycardia. Diagnosis is typically confirmed through computed tomography pulmonary angiography, biomarkers like D-dimer and cardiac troponins, and clinical scoring systems. Acute management focuses on hemodynamic support, including intravenous fluids and vasopressors, and may involve anticoagulation with low-molecular-weight heparin or direct oral anticoagulants. Severe cases may require systemic anticoagulation, catheter-directed techniques, and surgeries like pulmonary endarterectomy. Long-term management involves continued anticoagulation tailored to individual risk factors, with ongoing monitoring to prevent recurrence. Effective early diagnosis and management are crucial, as severe PE can significantly increase mortality and lead to serious complications. This review explores the pathophysiology, diagnosis, and management of PE and RVD.

3.
Circ Heart Fail ; 17(9): e011882, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39206568

RESUMEN

BACKGROUND: Patients with transposition of the great arteries (TGA) and systemic right ventricle often confront significant adverse cardiac events. The prognostic significance of invasive hemodynamic parameters in this context remains uncertain. Our hypothesis is that the aortic pulsatility index and hemodynamic profiling utilizing invasive measures provide prognostic insights for patients with TGA and a systemic right ventricle. METHODS: This retrospective multicenter cohort study encompasses adults with TGA and a systemic right ventricle who underwent cardiac catheterization. Data collection, spanning from 1994 to 2020, encompasses clinical and hemodynamic parameters, including measured and calculated values such as pulmonary capillary wedge pressure, aortic pulsatility index, and cardiac index. Pulmonary capillary wedge pressure and cardiac index values were used to establish 4 distinct hemodynamic profiles. A pulmonary capillary wedge pressure of ≥15 mm Hg indicated congestion, termed wet, while a cardiac index <2.2 L/min per m2 signified inadequate perfusion, labeled cold. The primary outcome comprised a composite of all-cause death, heart transplantation, or the requirement for mechanical circulatory support. RESULTS: Of 1721 patients with TGA, 242 individuals with available invasive hemodynamic data were included. The median follow-up duration after cardiac catheterization was 11.4 (interquartile range, 7.5-15.9) years, with a mean age of 38.5±10.8 years at the time of cardiac catheterization. Among hemodynamic parameters, an aortic pulsatility index <1.5 emerged as a robust predictor of the primary outcome, with adjusted hazard ratios of 5.90 (95% CI, 3.01-11.62; P<0.001). Among the identified 4 hemodynamic profiles, the cold/wet profile was associated with the highest risk for the primary outcome, with an adjusted hazard ratio of 3.83 (95% CI, 1.63-9.02; P<0.001). CONCLUSIONS: A low aortic pulsatility index (<1.5) and the cold/wet hemodynamic profile are linked with an elevated risk of adverse long-term cardiac outcomes in patients with TGA and systemic right ventricle.


Asunto(s)
Cateterismo Cardíaco , Ventrículos Cardíacos , Hemodinámica , Transposición de los Grandes Vasos , Humanos , Masculino , Femenino , Transposición de los Grandes Vasos/fisiopatología , Transposición de los Grandes Vasos/cirugía , Estudios Retrospectivos , Hemodinámica/fisiología , Adulto , Pronóstico , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Persona de Mediana Edad , Función Ventricular Derecha/fisiología , Presión Esfenoidal Pulmonar/fisiología
4.
Braz J Cardiovasc Surg ; 39(6): e20230244, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038261

RESUMEN

CLINICAL DATA: A nine-month-old female infant diagnosed with transposition of the great arteries with symptoms of heart failure associated with cyanosis and difficulty in gaining weight was referred to our center with late diagnosis (at nine months of age). CHEST RADIOGRAPHY: Cardiomegaly; attenuated peripheral vascular markings.Electrocardiography: Sinus rhythm with biventricular overload and aberrantly conducted supraventricular extra systoles. ECHOCARDIOGRAPHY: Wide atrial septal defect, ventricular axis torsion with concordant atrioventricular connection and discordant ventriculoarterial connection. COMPUTED TOMOGRAPHY ANGIOGRAPHY: Concordant atrioventricular connection, right ventricle positioned superiorly and left ventricle positioned inferiorly; discordant ventriculoarterial connection with right ventricle connected to the aorta and left ventricle connected to pulmonary artery. DIAGNOSIS: Crisscross heart is a rare congenital heart defect, accounting for 0.1% of congenital heart diseases. It consists of the 90º rotation of ventricles' axis in relation to their normal position; therefore, ventricles are positioned in the superior-inferior direction rather than anterior-posterior. Most cases have associated cardiac anomalies, and in this case, it is associated with transposition of the great arteries. The complexity and rarity of its occurrence make diagnosis and surgical treatment challenging. OPERATION: Modified Senning procedure using the pericardial sac in the construction of a tunnel from pulmonary veins to the right atrium. Cardiopulmonary bypass time of 147 minutes with nine minutes of total circulatory arrest.


Asunto(s)
Corazón con Ventrículos Entrecruzados , Transposición de los Grandes Vasos , Humanos , Femenino , Transposición de los Grandes Vasos/cirugía , Transposición de los Grandes Vasos/diagnóstico por imagen , Lactante , Corazón con Ventrículos Entrecruzados/cirugía , Corazón con Ventrículos Entrecruzados/diagnóstico por imagen , Ecocardiografía , Resultado del Tratamiento , Operación de Switch Arterial/métodos , Angiografía por Tomografía Computarizada , Electrocardiografía
5.
Med Biol Eng Comput ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39004652

RESUMEN

Percutaneous ventricular assist devices (pVADs) incorporated with admittance electrodes have been validated in animal studies for accurate instantaneous volumetric measurements. Since miniaturization of the pVAD profile is a priority to reduce vascular complications in patients, our study aimed to validate admittance measurements using three electrodes instead of the standard four. Complex admittance was measured between an electrode pair and a pVAD metallic blood-intake tip, both with finite element analysis and on the benchtop. The catheter and electrode arrays were first simulated inside prolate ellipsoid models of the left ventricle (LV) demonstrating current flow throughout all parts of the LV as well as minimal influence of off-center catheter placement in the recorded signal. Admittance measurements were validated in 3D-printed models of healthy and dilated hearts (100-400 mL end-diastolic volumes). Minimal interference between a pVAD motor and the current signal of our admittance system was demonstrated. A modified Wei's equation focused on three electrodes was developed to be compatible with reduced profile pVADs occurring clinically, incorporated with admittance electrodes and wires. The modified equation was compared against Wei's original equation showing improved accuracy of calculated volumes. Reducing electrode footprint can simplify the incorporation of Admittance technology on any pVAD, allowing for instantaneous recognition of native heart recovery and assistance with pVAD weaning.

6.
Circ Heart Fail ; 17(7): e011123, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38979607

RESUMEN

BACKGROUND: Systemic hemodynamics and specific ventilator settings have been shown to predict survival during venoarterial extracorporeal membrane oxygenation (ECMO). How the right heart (the right ventricle and pulmonary artery) affect survival during venoarterial ECMO is unknown. We aimed to identify the relationship between right heart function with mortality and the duration of ECMO support. METHODS: Cardiac ECMO runs in adults from the Extracorporeal Life Support Organization Registry between 2010 and 2022 were queried. Right heart function was quantified via pulmonary artery pulse pressure (PAPP) for pre-ECMO and on-ECMO periods. A multivariable model was adjusted for modified Society for Cardiovascular Angiography and Interventions stage, age, sex, and concurrent clinical data (ie, pulmonary vasodilators and systemic pulse pressure). The primary outcome was in-hospital mortality. RESULTS: A total of 4442 ECMO runs met inclusion criteria and had documentation of hemodynamic and illness severity variables. The mortality rate was 55%; nonsurvivors were more likely to be older, have a worse Society for Cardiovascular Angiography and Interventions stage, and have longer pre-ECMO endotracheal intubation times (P<0.05 for all) than survivors. Increasing PAPP from pre-ECMO to on-ECMO time (ΔPAPP) was associated with reduced mortality per 2 mm Hg increase (odds ratio, 0.98 [95% CI, 0.97-0.99]; P=0.002). Higher on-ECMO PAPP was associated with mortality reduction across quartiles with the greatest reduction in the third PAPP quartile (odds ratio, 0.75 [95% CI, 0.63-0.90]; P=0.002) and longer time on ECMO per 10 mm Hg (beta, 15 [95% CI, 7.7-21]; P<0.001). CONCLUSIONS: Early on-ECMO right heart function and interval improvement from pre-ECMO values were associated with mortality reduction during cardiac ECMO. Incorporation of right heart metrics into risk prediction models should be considered.


Asunto(s)
Presión Sanguínea , Oxigenación por Membrana Extracorpórea , Ventrículos Cardíacos , Arteria Pulmonar , Arteria Pulmonar/fisiopatología , Oxigenación por Membrana Extracorpórea/mortalidad , Hemodinámica , Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Ventrículos Cardíacos/fisiopatología
7.
Climacteric ; 27(5): 501-506, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39051435

RESUMEN

OBJECTIVES: Observational studies have suggested an association between age at natural menopause (ANM) and ventricular structure and function. Nevertheless, the causal relationship remains unclear. This study aimed to evaluate the causal effects of ANM on ventricular structure and function by Mendelian randomization (MR) analysis. METHODS: Genome-wide association summary statistics for ANM and 16 ventricular structures and functions were obtained. The inverse variance weighted (IVW) method was the primary MR approach for assessing causal associations. In addition, three additional MR methods (MR-Egger, weighted median and weighted mode) were performed to complement the IVW method. Furthermore, various sensitivity tests were conducted to evaluate the reliability of the MR results. RESULTS: The IVW method identified no causal association between ANM and all 16 ventricular structures or functions (p > 0.05). Three additional MR methods yielded parallel results to the IVW approach (p > 0.05). Various sensitivity tests revealed stability of the MR results, indicating no heterogeneity or horizontal pleiotropy. CONCLUSION: The present MR study indicated that ANM would not causally affect ventricular structure or function. Therefore, the correlation between ANM and ventricular characteristics in previous observational studies might be attributed to shared upstream cardiovascular risk factors or unidentified genetic mutations that simultaneously affect both ANM and ventricular structure and function.


Asunto(s)
Estudio de Asociación del Genoma Completo , Ventrículos Cardíacos , Análisis de la Aleatorización Mendeliana , Menopausia , Humanos , Femenino , Menopausia/genética , Persona de Mediana Edad , Ventrículos Cardíacos/anatomía & histología , Factores de Edad , Función Ventricular
8.
Circ Arrhythm Electrophysiol ; 17(8): e012814, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39051118

RESUMEN

BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7.5F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4-15g; median, 10g); (2) moderate (n=60; CF, 16-30g; median, 22.5g); (3) high (n=68; CF, 32-65g; median, 40g); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P<0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.


Asunto(s)
Ablación por Catéter , Animales , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Porcinos , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Catéteres Cardíacos , Diseño de Equipo , Miocardio/patología , Modelos Animales , Impedancia Eléctrica , Necrosis , Sus scrofa , Temperatura , Factores de Tiempo , Frecuencia Cardíaca
9.
Intern Med ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39048363

RESUMEN

Malignant cardiac lymphoma is rare and commonly involves nodules on the right side of the heart. We herein report a case of malignant cardiac lymphoma with diffuse extension into the left ventricle. The patient was a woman in her 60s who complained of dyspnea and malaise. Echocardiography revealed left ventricular hypertrophy (LVH), and magnetic resonance imaging revealed diffuse contrast enhancement on delayed contrast. Cardiac catheterization and a myocardial biopsy suggested heart failure due to cardiac malignant lymphoma, and diastolic dysfunction was mild despite LVH. The patient underwent chemotherapy, and her cardiac function improved and was maintained.

11.
Circ Arrhythm Electrophysiol ; 17(6): e012734, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38753535

RESUMEN

BACKGROUND: Endocardial catheter-based pulsed field ablation (PFA) of the ventricular myocardium is promising. However, little is known about PFA's ability to target intracavitary structures, epicardium, and ways to achieve transmural lesions across thick ventricular tissue. METHODS: A lattice-tip catheter was used to deliver biphasic monopolar PFA to swine ventricles under general anesthesia, with electroanatomical mapping, fluoroscopy and intracardiac echocardiography guidance. We conducted experiments to assess the feasibility and safety of repetitive monopolar PFA applications to ablate (1) intracavitary papillary muscles and moderator bands, (2) epicardial targets, and (3) bipolar PFA for midmyocardial targets in the interventricular septum and left ventricular free wall. RESULTS: (1) Papillary muscles (n=13) were successfully ablated and then evaluated at 2, 7, and 21 days. Nine lesions with stable contact measured 18.3±2.4 mm long, 15.3±1.5 mm wide, and 5.8±1.0 mm deep at 2 days. Chronic lesions demonstrated preserved chordae without mitral regurgitation. Two targeted moderator bands were transmurally ablated without structural disruption. (2) Transatrial saline/carbon dioxide assisted epicardial access was obtained successfully and epicardial monopolar lesions had a mean length, width, and depth of 30.4±4.2, 23.5±4.1, and 9.1±1.9 mm, respectively. (3) Bipolar PFA lesions were delivered across the septum (n=11) and the left ventricular free wall (n=7). Twelve completed bipolar lesions had a mean length, width, and depth of 29.6±5.5, 21.0±7.3, and 14.3±4.7 mm, respectively. Chronically, these lesions demonstrated uniform fibrotic changes without tissue disruption. Bipolar lesions were significantly deeper than the monopolar epicardial lesions. CONCLUSIONS: This in vivo evaluation demonstrates that PFA can successfully ablate intracavitary structures and create deep epicardial lesions and transmural left ventricular lesions.


Asunto(s)
Ablación por Catéter , Ventrículos Cardíacos , Tabique Interventricular , Animales , Tabique Interventricular/fisiopatología , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Porcinos , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Estudios de Factibilidad , Músculos Papilares/fisiopatología , Músculos Papilares/cirugía , Músculos Papilares/diagnóstico por imagen , Factores de Tiempo , Pericardio/cirugía , Pericardio/fisiopatología , Catéteres Cardíacos , Ultrasonografía Intervencional , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino
13.
Circ Genom Precis Med ; 17(3): e004320, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38804128

RESUMEN

BACKGROUND: Substantial data support a heritable basis for supraventricular tachycardias, but the genetic determinants and molecular mechanisms of these arrhythmias are poorly understood. We sought to identify genetic loci associated with atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular accessory pathways or atrioventricular reciprocating tachycardia (AVAPs/AVRT). METHODS: We performed multiancestry meta-analyses of genome-wide association studies to identify genetic loci for AVNRT (4 studies) and AVAP/AVRT (7 studies). We assessed evidence supporting the potential causal effects of candidate genes by analyzing relations between associated variants and cardiac gene expression, performing transcriptome-wide analyses, and examining prior genome-wide association studies. RESULTS: Analyses comprised 2384 AVNRT cases and 106 489 referents, and 2811 AVAP/AVRT cases and 1,483 093 referents. We identified 2 significant loci for AVNRT, which implicate NKX2-5 and TTN as disease susceptibility genes. A transcriptome-wide association analysis supported an association between reduced predicted cardiac expression of NKX2-5 and AVNRT. We identified 3 significant loci for AVAP/AVRT, which implicate SCN5A, SCN10A, and TTN/CCDC141. Variant associations at several loci have been previously reported for cardiac phenotypes, including atrial fibrillation, stroke, Brugada syndrome, and electrocardiographic intervals. CONCLUSIONS: Our findings highlight gene regions associated with ion channel function (AVAP/AVRT), as well as cardiac development and the sarcomere (AVAP/AVRT and AVNRT) as important potential effectors of supraventricular tachycardia susceptibility.


Asunto(s)
Estudio de Asociación del Genoma Completo , Taquicardia Supraventricular , Humanos , Taquicardia Supraventricular/genética , Predisposición Genética a la Enfermedad , Taquicardia por Reentrada en el Nodo Atrioventricular/genética , Polimorfismo de Nucleótido Simple , Conectina/genética , Transcriptoma
14.
Eur Radiol Exp ; 8(1): 51, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38517595

RESUMEN

BACKGROUND: To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS: Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-µm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS: Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS: CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT: Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS: • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.


Asunto(s)
Cateterismo de Swan-Ganz , Arteria Pulmonar , Humanos , Porcinos , Animales , Gasto Cardíaco/fisiología , Arteria Pulmonar/diagnóstico por imagen , Cateterismo de Swan-Ganz/métodos , Perfusión , Tomografía Computarizada por Rayos X
15.
Circ Cardiovasc Imaging ; 17(2): e016090, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38377242

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m2, LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m2, and LV mass index of 41 to 76 and 33 to 57 g/m2. For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m2, LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m2, and LV mass index of 50 to 83 and 38 to 65 g/m2. For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m2, RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m2, and RV mass index of 14 to 29 and 13 to 25 g/m2. CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.


Asunto(s)
Ventrículos Cardíacos , Función Ventricular Izquierda , Adulto , Masculino , Humanos , Femenino , Valores de Referencia , Teorema de Bayes , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Músculos Papilares , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética , Reproducibilidad de los Resultados
17.
Circ Genom Precis Med ; 17(2): e004404, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38353104

RESUMEN

BACKGROUND: Less than 40% of patients with dilated cardiomyopathy (DCM) have a pathogenic/likely pathogenic genetic variant identified. TBX20 has been linked to congenital heart defects; although an association with left ventricular noncompaction (LVNC) and DCM has been proposed, it is still considered a gene with limited evidence for these phenotypes. This study sought to investigate the association between the TBX20 truncating variant (TBX20tv) and DCM/LVNC. METHODS: TBX20 was sequenced by next-generation sequencing in 7463 unrelated probands with a diagnosis of DCM or LVNC, 22 773 probands of an internal comparison group (hypertrophic cardiomyopathy, channelopathies, or aortic diseases), and 124 098 external controls (individuals from the gnomAD database). Enrichment of TBX20tv in DCM/LVNC was calculated, cosegregation was determined in selected families, and clinical characteristics and outcomes were analyzed in carriers. RESULTS: TBX20tv was enriched in DCM/LVNC (24/7463; 0.32%) compared with internal (1/22 773; 0.004%) and external comparison groups (4/124 098; 0.003%), with odds ratios of 73.23 (95% CI, 9.90-541.45; P<0.0001) and 99.76 (95% CI, 34.60-287.62; P<0.0001), respectively. TBX20tv was cosegregated with DCM/LVNC phenotype in 21 families for a combined logarythm of the odds score of 4.53 (strong linkage). Among 57 individuals with TBX20tv (49.1% men; mean age, 35.9±20.8 years), 41 (71.9%) exhibited DCM/LVNC, of whom 14 (34.1%) had also congenital heart defects. After a median follow-up of 6.9 (95% CI, 25-75:3.6-14.5) years, 9.7% of patients with DCM/LVNC had end-stage heart failure events and 4.8% experienced malignant ventricular arrhythmias. CONCLUSIONS: TBX20tv is associated with DCM/LVNC; congenital heart defect is also present in around one-third of cases. TBX20tv-associated DCM/LVNC is characterized by a nonaggressive phenotype, with a low incidence of major cardiovascular events. TBX20 should be considered a definitive gene for DCM and LVNC and routinely included in genetic testing panels for these phenotypes.


Asunto(s)
Cardiomiopatía Dilatada , Cardiopatías Congénitas , Masculino , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Femenino , Cardiomiopatía Dilatada/patología , Cardiopatías Congénitas/genética , Arritmias Cardíacas , Fenotipo , Proteínas de Dominio T Box/genética
18.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38390748

RESUMEN

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Asunto(s)
Ablación por Catéter , Porcinos , Animales , Ablación por Catéter/efectos adversos , Ventrículos Cardíacos/cirugía , Catéteres , Diseño de Equipo
19.
Arq. bras. cardiol ; 121(1): e20230179, jan. 2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1533735

RESUMEN

Resumo Fundamento: O prolongamento do intervalo PQ, geralmente associado a um atraso na condução atrioventricular, pode estar relacionado a alterações na propagação do impulso intraventricular. Objetivo: Avaliar, por meio do mapeamento do potencial de superfície corporal (BSPM), o processo de despolarização ventricular em atletas com intervalos PQ prolongados em repouso e após o exercício. Métodos: O estudo incluiu 7 esquiadores cross-country com intervalo PQ superior a 200 ms (grupo PQ Prolongado) e 7 com intervalo PQ inferior a 200 ms (grupo PQ Normal). O BSPM de 64 derivações unipolares do tronco foi realizado antes (Pré-Ex) e após o teste ergométrico de bicicleta (Pós-Ex). Mapas equipotenciais da superfície corporal foram analisados durante a despolarização ventricular. O nível de significância foi de 5%. Resultados: Comparado com atletas com PQ Normal, o primeiro e o segundo períodos de posição estável dos potenciais cardíacos na superfície do tronco foram mais longos, e a formação da distribuição de potencial "sela" ocorreu mais tarde, no Pré-Ex, nos atletas com PQ Prolongado. No Pós-Ex, o grupo PQ Prolongado apresentou um encurtamento do primeiro e segundo períodos de distribuições de potencial estáveis e uma diminuição no tempo de aparecimento do fenômeno "sela" em relação ao Pré-Ex (para valores próximos aos do Normal -Grupo PQ). Além disso, no Pós-Ex, a primeira inversão das distribuições de potencial e a duração total da despolarização ventricular em atletas com PQ Prolongado diminuíram em comparação com o Pré-Ex e com valores semelhantes em atletas com PQ Normal. Em comparação com atletas com PQ Normal, a segunda inversão foi mais longa no Pré-Ex e Pós-Ex em atletas com PQ Prolongado. Conclusão: Atletas com PQ prolongado apresentaram diferenças significativas nas características temporais do BSPM durante a despolarização ventricular, tanto em repouso quanto após o exercício, em comparação com atletas com PQ normal.


Abstract Background: Prolongation of the PQ interval, generally associated with an atrioventricular conduction delay, may be related to changes in intraventricular impulse spreading. Objective: To assess, using body surface potential mapping (BSPM), the process of ventricular depolarization in athletes with prolonged PQ intervals at rest and after exercise. Methods: The study included 7 cross-country skiers with a PQ interval of more than 200 ms (Prolonged-PQ group) and 7 with a PQ interval of less than 200 ms (Normal-PQ group). The BSPM from 64 unipolar torso leads was performed before (Pre-Ex) and after the bicycle exercise test (Post-Ex). Body surface equipotential maps were analyzed during ventricular depolarization. The significance level was 5%. Results: Compared to Normal-PQ athletes, the first and second periods of the stable position of cardiac potentials on the torso surface were longer, and the formation of the "saddle" potential distribution occurred later, at Pre-Ex, in Prolonged-PQ athletes. At Post-Ex, the Prolonged-PQ group showed a shortening of the first and second periods of stable potential distributions and a decrease in appearance time of the "saddle" phenomenon relative to Pre-Ex (to the values near to those of the Normal-PQ group). Additionally, at Post-Ex, the first inversion of potential distributions and the total duration of ventricular depolarization in Prolonged-PQ athletes decreased compared to Pre-Ex and with similar values in Normal-PQ athletes. Compared to Normal-PQ athletes, the second inversion was longer at Pre-Ex and Post-Ex in Prolonged-PQ athletes. Conclusion: Prolonged-PQ athletes had significant differences in the temporal characteristics of BSPM during ventricular depolarization both at rest and after exercise as compared to Normal-PQ athletes.

20.
Rev. bras. cir. cardiovasc ; 39(6): e20230244, 2024. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1569629

RESUMEN

ABSTRACT Clinical data: A nine-month-old female infant diagnosed with transposition of the great arteries with symptoms of heart failure associated with cyanosis and difficulty in gaining weight was referred to our center with late diagnosis (at nine months of age). Chest radiography: Cardiomegaly; attenuated peripheral vascular markings. Electrocardiography: Sinus rhythm with biventricular overload and aberrantly conducted supraventricular extra systoles. Echocardiography: Wide atrial septal defect, ventricular axis torsion with concordant atrioventricular connection and discordant ventriculoarterial connection. Computed tomography angiography: Concordant atrioventricular connection, right ventricle positioned superiorly and left ventricle positioned inferiorly; discordant ventriculoarterial connection with right ventricle connected to the aorta and left ventricle connected to pulmonary artery. Diagnosis: Crisscross heart is a rare congenital heart defect, accounting for 0.1% of congenital heart diseases. It consists of the 90º rotation of ventricles' axis in relation to their normal position; therefore, ventricles are positioned in the superior-inferior direction rather than anterior-posterior. Most cases have associated cardiac anomalies, and in this case, it is associated with transposition of the great arteries. The complexity and rarity of its occurrence make diagnosis and surgical treatment challenging. Operation: Modified Senning procedure using the pericardial sac in the construction of a tunnel from pulmonary veins to the right atrium. Cardiopulmonary bypass time of 147 minutes with nine minutes of total circulatory arrest.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA