1.
Comput Struct Biotechnol J ; 20: 2558-2563, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35611117

RESUMEN

The SARS-CoV-2 Variants of Concern tracking via Whole Genome Sequencing represents a pillar of public health measures for the containment of the pandemic. The ability to track down the lineage distribution on a local and global scale leads to a better understanding of immune escape and to adopting interventions to contain novel outbreaks. This scenario poses a challenge for NGS laboratories worldwide that are pressed to have both a faster turnaround time and a high-throughput processing of swabs for sequencing and analysis. In this study, we present an optimization of the Illumina COVID-seq protocol carried out on thousands of SARS-CoV-2 samples at the wet and dry level. We discuss the unique challenges related to processing hundreds of swabs per week such as the tradeoff between ultra-high sensitivity and negative contamination levels, cost efficiency and bioinformatics quality metrics.

2.
Mol Genet Metab Rep ; 19: 100467, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30963030

RESUMEN

Blood phenylalanine (Phe) values from the dried blood spots of all Estonian phenylketonuria (PKU) patients have been deposited into a unified electronic laboratory database for eight years, providing an opportunity to assess the adherence of the patients to dietary recommendations over time and to observe patient practices both individually and collectively. Our results demonstrate generally good adherence to clinical and dietary recommendations during the first six years of life, as the percentage of patients with median Phe values fitting under the national recommendation levels were 95%, 84% and 70% in age groups 0-1, 1-2 and 2-6 years, respectively. Conversely, significant deviations occur in the group of 6 to 12 year-olds, mildly decreasing in adolescence and increasing in adulthood (43%, 53% and 57%, respectively). Wide individual differences occurred in all groups, especially in patients with a classical PKU phenotype caused by PAH variants that fully abolish phenylalanine hydroxylase activity. Surprisingly, some of the best dietary adherence was seen in the late-diagnosed PKU patients with poor cognitive functioning. As a rule, the median of Phe values crosses the recommended thresholds in approximately one third to one half of the patients of each age group after the first two years of life.

3.
Pract Lab Med ; 5: 65-74, 2016 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28856206

RESUMEN

OBJECTIVES: Refractometers are commonly used to determine urine specific gravity (SG) in the assessment of hydration status and urine specimen validity testing. Few comprehensive performance evaluations are available demonstrating refractometer capability from a clinical laboratory perspective. The objective of this study was therefore to conduct an analytical validation of a handheld digital refractometer used for human urine SG testing. DESIGN AND METHODS: A MISCO Palm Abbe™ refractometer was used for all experiments, including device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, evaluation of potential substances which contribute to SG (i.e. "interference"), and reference interval evaluation. A manual refractometer, urine osmometer, and a solute score (sum of urine chloride, creatinine, glucose, potassium, sodium, total protein, and urea nitrogen; all in mg/dL) were used as comparative methods for accuracy assessment. RESULTS: Significant carryover was not observed. A wash step was still included as good laboratory practice. Low imprecision (%CV, <0.01) was demonstrated using low and high QC material. Accuracy studies showed strong correlation to manual refractometry. Linear correlation was also demonstrated between SG, osmolality, and solute score. Linearity of Palm Abbe performance was verified with observed error of ≤0.1%. Increases in SG were observed with increasing concentrations of albumin, creatinine, glucose, hemoglobin, sodium chloride, and urea. Transference of a previously published urine SG reference interval of 1.0020-1.0300 was validated. CONCLUSIONS: The Palm Abbe digital refractometer was a fast, simple, and accurate way to measure urine SG. Analytical validity was confirmed by the present experiments.