Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
Crit Care ; 28(1): 328, 2024 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375782

RESUMEN

Point of Care ultrasound (POCUS) of the lungs, also known as lung ultrasound (LUS), has emerged as a technique that allows for the diagnosis of many respiratory pathologies with greater accuracy and speed compared to conventional techniques such as chest x-ray and auscultation. The goal of this narrative review is to provide a simple and practical approach to LUS for critical care, pulmonary, and anesthesia providers, as well as respiratory therapists and other health care providers to be able to implement this technique into their clinical practice. In this review, we will discuss the basic physics of LUS, provide a hands-on scanning technique, describe LUS findings seen in normal and pathological conditions (such as mainstem intubation, pneumothorax, atelectasis, pneumonia, aspiration, COPD exacerbation, cardiogenic pulmonary edema, ARDS, and pleural effusion) and also review the training necessary to achieve competence in LUS.


Asunto(s)
Pulmón , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Ultrasonografía/métodos , Pulmón/diagnóstico por imagen , Sistemas de Atención de Punto/normas , Sistemas de Atención de Punto/tendencias , Enfermedades Pulmonares/diagnóstico por imagen
2.
Cureus ; 16(8): e66064, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39224711

RESUMEN

Pulmonary ultrasound has become a fundamental tool for the early detection and management of major neonatal lung diseases in neonatal intensive care units (NICUs). The advantages of this imaging investigation include its rapid execution and information acquisition, non-invasive nature, early diagnosis establishment, dynamic monitoring, and usefulness in therapeutic management. Regarding therapeutic management, the lung ultrasound (LUS) score is used as a basic tool for indicating surfactant administration. Performing and interpreting pulmonary ultrasounds requires an experienced clinician capable of recognizing anatomical structures, understanding the limitations of the technique, and correlating the obtained data with the patient's clinical picture. A series of diagnostic characteristics of pulmonary ultrasonography for neonatal lung pathologies have been described, making pulmonary ultrasound a useful tool in establishing differential diagnoses. This study evaluates the effectiveness of ultrasonography in determining the severity of lung pathologies in newborns and its impact on therapeutic decision-making, including surfactant administration and continuous positive airway pressure (CPAP) support. Newborns admitted to the NICU with various respiratory conditions underwent LUS scoring. The study analyzed the relationship between LUS scoring and the severity of conditions such as pneumonia, respiratory distress syndrome, meconium aspiration syndrome, transient tachypnea of the newborn, and pneumothorax. The correlation between LUS scoring, surfactant administration, and CPAP requirements was also examined.

3.
BMC Med Educ ; 24(1): 939, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198828

RESUMEN

BACKGROUND: Objective assessment of skills after training is essential for safe implementation of lung point-of-care ultrasound (POCUS). In low-and middle-income countries (LMIC) there is a need for assessment tools without onsite experts to scale up POCUS access. Our objective is to develop a web-based assessment tool and evaluate trainees across different countries and at different time points after initial lung POCUS training. METHODS: We adapted the objective and validated lung ultrasound score (LUS-OSAUS) to a web-based tool with quiz and practical skills test. Trainees were evaluated after a short (4-day) standardized lung POCUS training and were classified in distinct groups according to (i) their geographical location (Benin vs. South-Africa) and (ii) time elapsed since training (Benin 0 months vs. Benin 6 months). The Benin 6 months group had minimal continuous education. Skills test images were read by two blinded experts. We report the overall success rates and then compare these rates based on location and timing since training, using the Fischer's exact test. RESULTS: A total of 35 out of 43 participants completed the online LUS-OSAUS quiz and skills test. The overall success rate was 0.84 (95%CI 0.80-0.88), with lower success rates for "correct depth" 0.54 (0.37-0.71), "correct assessment of pleura" 0.63 (0.45-0.79) and "conclusion" 0.71 (0.54-0.85). There were no differences based on location, with respective rates of 0.86 (0.80-0.92) and 0.83 (0.75-0.91) (p-value = 0.125) for Benin and South Africa at 0 months, respectively. Similarly, there were no differences according to timing with success rates of 0.86 (0.80-0.92) and 0.82 (0.72-0.93) (p-value = 0.563) for Benin at 0 months and 6 months, respectively. CONCLUSION: Web-based objective and structured assessment of lung POCUS skills in LMIC following a short-standardized training is feasible and has a good overall success rate with consistent results across regions and up to 6 months after training given minimal continuous education. Overall, technical and POCUS-based clinical conclusion skills are the most difficult to acquire.


Asunto(s)
Competencia Clínica , Países en Desarrollo , Pulmón , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Pulmón/diagnóstico por imagen , Internet , Evaluación Educacional , Sudáfrica , Configuración de Recursos Limitados
4.
Transl Androl Urol ; 13(7): 1302-1308, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39100844

RESUMEN

Background: Conventional vascular interventions and hybrid surgery relied on digital subtraction angiography (DSA). Previously our center explored hybrid partial nephrectomy with DSA guidance, which demonstrates the superiority of omitting the dissection of renal hilum. However, this approach is limited to scarce hybrid operating rooms, involves radiation exposure, and poses compatibility issues with robotic surgery platforms. Laparoscopic ultrasound (LUS) can assist in robotic surgery. This study explored the application of LUS-guided occlusion of renal artery blood supply with a Fogarty balloon catheter, particularly in hybrid partial nephrectomy for renal tumor treatment. Case Description: The LUS-guided renal artery balloon catheter occluded hybrid partial nephrectomy (UBo-HPN) involved several steps: trans-femoral artery cannulation, placement of the balloon catheter into the renal artery via the femoral vascular sheath, occlusion of the renal blood supply by inflating the balloon catheter, completion of zero-ischemia partial nephrectomy with arterial flow occluded, withdrawal of the balloon catheter after deflation. For all three patients, the balloon catheter was successfully and accurately placed into the selected renal artery under LUS guidance. Intraoperative occlusion of the renal blood supply was confirmed to be complete and reversible. No complications were observed during follow-up. Conclusions: LUS guidance presents a safe alternative to DSA guidance for assisting in hybrid surgery. LUS-guided hybrid partial nephrectomy is safe and feasible.

5.
Egypt Heart J ; 76(1): 98, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39105939

RESUMEN

BACKGROUND: Heart failure (HF) poses a major health problem, where frequent HF rehospitalizations (HFH) heavily burden national health systems. HFH are predominantly linked to inadequate decongestion before discharge. It is uncertain if systematic implementation of cardio-pulmonary ultra-sound imaging (CPUSI) to standard HF management can improve outcomes and reduce HFH. RESULTS: This study recruited 50 patients admitted with acute decompensated heart failure (ADHF). Besides the conventional daily assessment, CPUSI was systematically performed to guide treatment decisions, focusing on ventricular filling pressure and 8-zone lung ultrasound (LUS) score. On-admission and predischarge LUS scores were correlated to clinical outcomes. The mean age of the study group was 55.7 ± 10.59 years, with predominance of male gender. Supplementing clinical judgment, CPUSI modified therapeutic strategy in 57 out of 241 assessments (24%), improving patients' care. Besides its value in guiding therapeutic decisions, the LUS score on admission had a significant positive correlation to the length of ICU stay and the total hospitalization length. Also, LUS score > 12 at discharge predicted 90-day HFH with sensitivity and specificity of 100% and 98%, respectively. CONCLUSIONS: Systematic CPUSI can improve HF management by complementing the often challenging judgment of pulmonary congestion. Adding periodic evaluation of ventricular filling pressures and LUS scores to clinical assessment can optimize treatment decisions and improve patient care. LUS score was a significant predictor for in-hospital and post-discharge clinical outcomes.

7.
Eur J Pediatr ; 183(10): 4309-4317, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39073470

RESUMEN

Moderate-to-large patent ductus arteriosus (PDA) has been linked to increased risk of bronchopulmonary dysplasia (BPD), while lung ultrasound score (LUS) has been demonstrated to accurately predict BPD. We aimed to investigate the correlation of LUS as a marker of interstitial pulmonary edema and the severity of the ductal shunt in predicting future BPD development in very preterm infants. This secondary analysis of a prospective study recruited preterm infants with gestational age < 30 weeks. LUS on postnatal days 7 and 14, and echocardiographic data [PDA diameter and left atrium-to-aortic root ratio (LA/Ao)] near LUS acquisition were collected. Correlation coefficient, logistics regression analysis, and the area under the receiver operating characteristic (AUROC) procedure were used. A statistically significant and positive correlation existed between LUS and PDA diameter (ρ = 0.415, ρ = 0.581, and p < 0.001) and LA/Ao (ρ = 0.502, ρ = 0.743, and p < 0.001) at postnatal days 7 and 14, respectively, and the correlations of LUS and echocardiographic data were generally stronger in the non-BPD group. In the prediction of BPD, LUS incorporating echocardiographic data at postnatal days 7 obtained significantly higher predictive performance compared to LUS alone (AUROC 0.878 [95% CI 0.801-0.932] vs. AUROC 0.793 [95% CI 0.706-0.865]; Delong test, p = 0.013). CONCLUSIONS: There is a statistically significant correlation between LUS and echocardiographic data, suggesting their potential role as early predictors for respiratory outcomes in very preterm infants. WHAT IS KNOWN: • Lung ultrasound score (LUS) has shown good reliability in predicting bronchopulmonary dysplasia (BPD) development. • Some echocardiographic data that characterized ventricular function was reported to be used to predict severe BPD. WHAT IS NEW: • There is a positive and statistically significant correlation between LUS and echocardiographic data at postnatal days 7 and 14. • The integrated use of LUS and echocardiographic data may have potential value in predicting BPD.


Asunto(s)
Displasia Broncopulmonar , Conducto Arterioso Permeable , Humanos , Displasia Broncopulmonar/diagnóstico por imagen , Conducto Arterioso Permeable/diagnóstico por imagen , Estudios Prospectivos , Recién Nacido , Femenino , Masculino , Pulmón/diagnóstico por imagen , Recien Nacido Prematuro , Ecocardiografía/métodos , Ultrasonografía/métodos , Curva ROC , Índice de Severidad de la Enfermedad
8.
Diagnostics (Basel) ; 14(13)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-39001302

RESUMEN

The use of lung ultrasonography in neonates is increasing at a very fast rate. Evidence-based guidelines on the use of lung ultrasound (LU) in neonates and children have been published and well received across the world. However, there remains a lack of standardized curriculum for lung ultrasound training and standards for its application at the bedside. This article focuses on providing a standardized approach to the application of lung ultrasonography in neonates for the common neonatal conditions and how it can be integrated into bedside clinical decision-making.

9.
Sci Rep ; 14(1): 16376, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013906

RESUMEN

One of the important problems in the environment is heavy metal pollution, and fluorescence is one of the best methods for their detection due to its sensitivity, selectivity, and relatively rapid and easy operation. In this study, 1,8-diaminonaphthalene functionalized super-stable mesoporous silica (DAN-LUS-1) was synthesized and used as a fluorescence probe to identify Hg2+ and Fe3+ in food samples. The TGA and FT-IR spectra illustrated that 1,8-diaminonaphthalene was grafted into LUS-1. XRD patterns verified that the LUS-1 and functionalized mesoporous silica have a hexagonal symmetrical array of nano-channels. SEM images showed that the rod-like morphology of LUS-1 was preserved in DAN-LUS-1. Also, surface area and pore diameter decreased from 824 m2 g⁻1 and 3.61 nm for the pure LUS-1 to 748 m2 g⁻1 and 3.43 nm for the DAN-LUS-1, as determined by N2 adsorption-desorption isotherms. This reduction demonstrated that 1,8-diaminonaphthalene immobilized into the pore of LUS-1. The DAN-LUS-1 fluorescence properties as a chemical sensor were studied with a 340/407 nm excitation/emission wavelength that was quenched by Hg2+ and Fe3+ ions. Hg2+ and Fe3+ were quantified using the fluorescence response in the working range 8.25-13.79 × 10-6 and 3.84-10.71 × 10-6 mol/L, with detection limits of 8.5 × 10-8 M and 1.3 × 10-7 M, respectively. Hg2+ and Fe3+ were measured in vetiver grass and spinach. Since the Fe3+ quenching can move in the opposite direction with sodium hexametaphosphate (SHMP) as a hiding compound for Fe3+, consequently, the circuit logic system was established with Fe3+, Hg2+, and SHMP as inputs and the fluorescent quench as the output.

10.
Front Oncol ; 14: 1398347, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38863633

RESUMEN

Objectives: This study aimed to explore the feasibility and safety of laparoscopic nephron-sparing surgery (LNSS) for complex renal cystic lesions. Methods: A retrospective study was conducted on 83 cases of complex renal cystic lesions treated with LNSS in our hospital. There were 32 men and 51 women, ranging in age from 24 to 73 years (average, 47.22 ± 9.03 years). The diameter of the cysts was 1.5-5.9 cm (average, 3.44 ± 0.86cm). According to the Bosniak classification, there were 15 cases of type II, 23 cases of type IIF, 29 cases of type III, and 16 cases of type IV complex renal cystic lesions. According to clinical classification based on the difficulty of laparoscopic partial nephrectomy and the depth of the lesion, the 83 complex renal cystic lesions were divided into 48 cases of the extra-renal type, 15 cases of the centrally located type, seven cases of the renal sinus type, and 13 cases of the renal hilum type. Results: Laparoscopic partial nephrectomy was successful in all 83 patients. The surgical time was 35-102 min (average, 52.13 ± 14.38 min), the intraoperative bleeding volume was 10-200 ml (average, 27.25 ± 12.26 ml), and the renal artery occlusion time was 12-28 min (average, 12.46 ± 4.45 min). There was no significant change in creatinine before and after surgery. The postoperative pathological results showed 71 cases of renal clear cell carcinoma, five cases of low malignant potential multilocular cystic renal tumors, and seven cases of pure renal cysts with all margins negative. Conclusions: There is potential for the malignant transformation of complex renal cysts into renal cell carcinoma. For complex renal cysts classified as Bosniak IIF or higher, surgical intervention is recommended, and LNSS is safe and effective. The complexity of the surgical procedure varies depending on the location classification of the complex renal cysts.

11.
Cureus ; 16(6): e63051, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38915837

RESUMEN

Purpose The number of B-lines on lung ultrasound at hospital discharge in patients admitted with acute heart failure (AHF) is associated with poor outcomes. Assessing B-lines can be challenging to execute and replicate, depending on the clinical context. This study aims to determine whether the lung ultrasound score (LUS) at discharge predicts hospital readmission or emergency department (ED) visits in the 30 days after an AHF hospital admission. Methods  We conducted an observational study at the medical ward of the emergency unit of the Clinics Hospital of the Ribeirao Preto Medical School, University of Sao Paulo, a tertiary university hospital in Ribeirao Preto, Sao Paulo, Brazil, where consecutive adults admitted with AHF were included. On the day of hospital discharge, we measured the LUS and tracked these patients for up to 30 days to monitor emergency department visits, hospital readmission, and the number of days free from hospital stay. Results  A total of 46 patients were included in the study. A composite outcome of ED visits or hospital readmission in the 30 days after hospital discharge was achieved for 22 (47.8%) patients. The LUS at hospital discharge had a receiver operating characteristic (ROC) area of 0.93 (95% CI, 0.82-0.99) to predict the composite outcome, against 0.67 (95% CI, 0.52-0.81) for the clinical congestion score (CCS). A LUS ≥ 7 at discharge had a sensitivity of 95.5% and a specificity of 87.5% to predict the composite outcome. The average exam duration was 176±65 (sd) seconds. Conclusions The LUS at hospital discharge following admission for AHF proves to be an accurate tool for predicting the likelihood of return to the ED and/or hospital readmission within 30 days post discharge.

12.
Life (Basel) ; 14(6)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38929715

RESUMEN

AIM: our study aimed to characterize the lung ultrasound (LUS) patterns noted immediately after delivery in term and near-term neonates, and to investigate whether the LUS scores or patterns observed at that point could anticipate the need for respiratory support in the sample of patients studied. MATERIALS AND METHODS: We performed two ultrasound examinations: one in the delivery room and the second at one hour of age. The anterior and lateral regions of both lungs were examined. We assessed the correlation between the LUS scores or patterns and the gestational age, umbilical arterial blood gases, the need for respiratory support (CPAP or mechanical ventilation), the presence of respiratory distress, and the need for the administration of oxygen. RESULTS: LUS scores were significantly higher in the delivery room examination (8.05 ± 1.95) than at 1 h of age (6.4 ± 1.75) (p < 0.001). There were also statistically significant differences between the LUS patterns observed in different lung regions between the delivery room exam and the exam performed at 1 h of age (p values between 0.001 and 0.017). There were also differences noted regarding the LUS patterns between different lung regions at the exam in the delivery room (the right anterior region LUS patterns were significantly worse than the right lateral LUS patterns (p < 0.004), left anterior LUS patterns (p < 0.001), and left lateral LUS patterns (p < 0.001)). A statistically significant correlation was found between LUS scores and the gestational age of the patients (r = 0.568, p < 0.001-delivery room; r = 4.0443, p < 0.001-one hour of age). There were statistically significant associations between LUS scores, patterns at delivery (p < 0.001) and 1 h of age (p < 0.001), and the need for respiratory support (CPAP or mechanical ventilation). CONCLUSIONS: LUS in the delivery room offers important information regarding lung fluid elimination and aeration of the lungs, and early LUS features are significantly associated with the risk of respiratory distress and the need for respiratory support.

13.
Int J Mol Sci ; 25(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38891818

RESUMEN

In eutocic labor, the autonomic nervous system is dominated by the parasympathetic system, which ensures optimal blood flow to the uterus and placenta. This study is focused on the detection of the quantitative presence of catecholamine (C) neurofibers in the internal uterine orifice (IUO) and in the lower uterine segment (LUS) of the pregnant uterus, which could play a role in labor and delivery. A total of 102 women were enrolled before their submission to a scheduled cesarean section (CS); patients showed a singleton fetus in a cephalic presentation outside labor. During CS, surgeons sampled two serial consecutive full-thickness sections 5 mm in depth (including the myometrial layer) on the LUS and two randomly selected samples of 5 mm depth from the IUO of the cervix. All histological samples were studied to quantify the distribution of A nerve fibers. The authors demonstrated a significant and notably higher concentration of A fibers in the IUO (46 ± 4.8) than in the LUS (21 ± 2.6), showing that the pregnant cervix has a greater concentration of A neurofibers than the at-term LUS. Pregnant women's mechanosensitive pacemakers can operate normally when the body is in a physiological state, which permits normal uterine contractions and eutocic delivery. The increased frequency of C neurofibers in the cervix may influence the smooth muscle cell bundles' activation, which could cause an aberrant mechano-sensitive pacemaker activation-deactivation cycle. Stressful circumstances (anxiety, tension, fetal head position) cause the sympathetic nervous system to become more active, working through these nerve fibers in the gravid cervix. They might interfere with the mechano-sensitive pacemakers, slowing down the uterine contractions and cervix ripening, which could result in dystocic labor.


Asunto(s)
Catecolaminas , Cuello del Útero , Miometrio , Humanos , Femenino , Embarazo , Cuello del Útero/metabolismo , Adulto , Catecolaminas/metabolismo , Miometrio/metabolismo , Contracción Uterina , Fibras Nerviosas/metabolismo , Cesárea
14.
Heliyon ; 10(10): e31293, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38813155

RESUMEN

Background: Several studies have shown that bedside lung ultrasound findings in postanaesthesia care units (PACUs) and intensive care units (ICUs) correlate with postoperative pulmonary complications(PPCs) after noncardiac major surgery. However, it remains unclear whether lung ultrasound findings can be used as early predictors of PPCs in patients undergoing cardiac surgery. The main aim of our study was to evaluate the relationship between early postoperative point-of-care lung ultrasound findings and PPCs after cardiac surgery. Methods: Two board-certified physicians performed a point-of-care pulmonary ultrasound on cardiac surgery patients approximately 2 h after the patient was admitted to the ICU. Pulmonary complications occurring within 30 days postoperatively were recorded. Logistic regression modeling was used to analyze the relationship between lung ultrasound findings and PPCs. Results: PPCs occurred in 61 (30.9 %) of the 197 patients. Lung ultrasound scores(LUS), number of lung consolidation(NLC), and depth of pleural effusion(DPE) were more significant in patients who developed PPCs (P < 0.001). According to the multivariate analysis, NLC≥3(aOR 2.71,95%CI 1.14-6.44; p = 0.024)and DPE >0.95(aOR 3.79,95%CI 1.60-8.99; p = 0.002) were found to be independently associated with PPCs during this study. Conclusions: Our study demonstrated that DPE >0.95 and NLC ≥3 were associated with PPCs after cardiac surgery based on bedside lung ultrasound findings in the ICU. When these signs manifest perioperatively, the surgeon should be alerted and the necessary steps should be taken, especially if they present simultaneously.

15.
Pol J Radiol ; 89: e211-e224, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38783909

RESUMEN

In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of this review we discuss lines, signs and pheno-mena, profiles, some applications, and misconceptions. An aim of the second part of the review is mainly to discuss some advanced applications of LUS, including lung elastography, lung spectroscopy, colour and spectral Doppler, contrast-enhanced ultrasound of lung, speckled tracking of pleura, quantification of pulmonary oedema, predicting success of talc pleurodesis, asthma exacerbations, detecting chest wall invasion by tumours, lung biopsy, estimating pleural effusion volume, and predicting mechanical ventilatory weaning outcome. For this purpose, we reviewed literature concerning LUS.

16.
Children (Basel) ; 11(5)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38790587

RESUMEN

Ventilator-associated pneumonia (VAP) is common in Pediatric Intensive Care Units. Although early detection is crucial, current diagnostic methods are not definitive. This study aimed to identify lung ultrasound (LUS) findings and procalcitonin (PCT) values in pediatric patients with VAP to create a new early diagnosis score combined with the Clinical Pulmonary Infection Score (CPIS), the CPIS-PLUS score. Prospective longitudinal and interventional study. Pediatric patients with suspected VAP were included and classified into VAP or non-VAP groups, based on Centers of Disease Control (CDC) criteria for the final diagnosis. A chest-X-ray (CXR), LUS, and blood test were performed within the first 12 h of admission. CPIS score was calculated. A total of 108 patients with VAP suspicion were included, and VAP was finally diagnosed in 51 (47%) patients. CPIS-PLUS showed high accuracy in VAP diagnosis with a sensitivity (Sn) of 80% (95% CI 65-89%) and specificity (Sp) of 73% (95% CI 54-86%). The area under the curve (AUC) resulted in 0.86 for CPIS-PLUS vs. 0.61 for CPIS. In conclusion, this pilot study showed that CPIS-PLUS could be a potential and reliable tool for VAP early diagnosis in pediatric patients. Internal and external validations are needed to confirm the potential value of this score to facilitate VAP diagnosis in pediatric patients.

17.
Nefrologia (Engl Ed) ; 44(2): 159-164, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38631962

RESUMEN

Hyponatremia is a multifactorial disorder defined as a decrease in plasma sodium concentration. Its differential diagnosis requires an adequate evaluation of the extracellular volume (ECV). However, ECV determination, simply based on the clinical history, vital signs, physical examination, and laboratory findings can leads to misdiagnosis and inappropriate treatment. The use of Point-of-Care Ultrasound (POCUS), through the combination of Lung Ultrasound (LUS), Venous Excess UltraSound (VExUS) and Focused Cardiac Ultrasound (FoCUS), allows a much more accurate holistic assessment of the patient's ECV status in combination with the other parameters.


Asunto(s)
Hiponatremia , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Hiponatremia/etiología , Hiponatremia/diagnóstico por imagen , Ultrasonografía/métodos , Medicina de Precisión , Pulmón/diagnóstico por imagen
18.
BMC Med Educ ; 24(1): 166, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38383377

RESUMEN

BACKGROUND: Lung ultrasound has been increasingly used in the last years for the assessment of patients with respiratory diseases; it is considered a simple technique, now spreading from physicians to other healthcare professionals as nurses and physiotherapists, as well as to medical students. These providers may require a different training to acquire lung ultrasound skills, since they are expected to have no previous experience with ultrasound. The aim of the study was to assess the impact of a short theoretical training focused on lung ultrasound pattern recognition in a population of novice nurse learners with no previous experience with ultrasound. METHODS: We included the nurses attending a critical care advanced course for nurses performed at the University of Pavia. Images' interpretation skills were tested on two slide sets (a 25-clip set focused on B-pattern recognition and a 25-clip set focused on identification of pleural movement as lung sliding, lung pulse, lung point, no movement) before and after three 30-minute teaching modules dedicated to general ultrasound principles, B-lines assessment and lung sliding assessment. A cut off of 80% was considered acceptable for correctly interpreted images after this basic course. RESULTS: 22 nurses were enrolled (age 26.0 [24.0-28.0] years; men 4 (18%)); one nurse had previous experience with other ultrasound techniques, none of them had previous experience with lung ultrasound. After the training, the number of correctly interpreted clips improved from 3.5 [0.0-13.0] to 22.0 [19.0-23.0] (p < 0.0001) for B-pattern and from 0.5 [0.0-2.0] to 8.5 [6.0-12.0] (p < 0.0001) for lung sliding assessment. The number of correct answers for B-pattern recognition was significantly higher than for lung sliding assessment, both before (3.5 [0.0-13.0] vs. 0.5 [0.0-2.0]; p = 0.0036) and after (22.0 [19.0-23.0] vs. 8.5 [6.0-12.0]; p < 0.0001) the training. After the training, nurses were able to correctly recognize the presence or the absence of a B-pattern in 84.2 ± 10.3% of cases; lung sliding was correctly assessed in 37.1 ± 15.3% of cases. CONCLUSIONS: Lung ultrasound is considered a simple technique; while a short, focused training significantly improves B-pattern recognition, lung sliding assessment may require a longer training for novice learners. TRIAL REGISTRATION: Not applicable.


Asunto(s)
Pulmón , Médicos , Masculino , Humanos , Adulto , Pulmón/diagnóstico por imagen , Ultrasonografía
19.
J Clin Med ; 13(2)2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38256439

RESUMEN

Artificial intelligence (AI) can make intelligent decisions in a manner akin to that of the human mind. AI has the potential to improve clinical workflow, diagnosis, and prognosis, especially in radiology. Acute respiratory distress syndrome (ARDS) is a very diverse illness that is characterized by interstitial opacities, mostly in the dependent areas, decreased lung aeration with alveolar collapse, and inflammatory lung edema resulting in elevated lung weight. As a result, lung imaging is a crucial tool for evaluating the mechanical and morphological traits of ARDS patients. Compared to traditional chest radiography, sensitivity and specificity of lung computed tomography (CT) and ultrasound are higher. The state of the art in the application of AI is summarized in this narrative review which focuses on CT and ultrasound techniques in patients with ARDS. A total of eighteen items were retrieved. The primary goals of using AI for lung imaging were to evaluate the risk of developing ARDS, the measurement of alveolar recruitment, potential alternative diagnoses, and outcome. While the physician must still be present to guarantee a high standard of examination, AI could help the clinical team provide the best care possible.

20.
Quant Imaging Med Surg ; 14(1): 123-135, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38223084

RESUMEN

Background: Lung ultrasound (LUS) and diaphragm ultrasound (DUS) are the appropriate modalities for conservative observation to those patients who are with stable pneumothorax, as well as for the timely detection of life-threatening pneumothorax at any location, due to they are portable, real-time, relatively cost effective, and most important, without radiation exposure. The absence of lung sliding on LUS M-mode images and the abnormality of diaphragmatic excursion (DE) on DUS M-mode images are the most common and novel diagnostic criteria for pneumothorax, respectively. However, visual inspection of M-mode images remains subjective and quantitative analysis of LUS and DUS M-mode images are required. Methods: Shannon entropy of LUS M-mode image (ShanEnLM) and DE based on the automated measurement (DEAM) are adapted to the objective pneumothorax diagnoses and the severity quantifications in this study. Mild, moderate, and severe pneumothoraces were induced in 24 male New Zealand rabbits through insufflation of room air (5, 10 and 15, and 25 and 40 mL/kg, respectively) into their pleural cavities. In vivo intercostal LUS and subcostal DUS M-mode images were acquired using a point-of-care system for estimating ShanEnLM and DEAM. Results: ShanEnLM and DEAM as functions of air insufflation volumes exhibited U-shaped curves and were exponentially decreasing, respectively. Either ShanEnLM or DEAM had areas under the receiver operating characteristic curves [95% confidence interval (CI)] of 1.0000 (95% CI: 1.0000-1.0000), 0.9833 (95% CI: 0.9214-1.0000), and 0.9407 (95% CI: 0.8511-1.0000) for differentiating between normal and mild pneumothorax, mild and moderate pneumothoraces, and moderate and severe pneumothoraces, respectively. Conclusions: Our findings imply that the combination of ShanEnLM and DEAM give the promising potential for pneumothorax quantitative diagnosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA