Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Curr Glaucoma Pract ; 18(1): 10-15, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38585165

RESUMEN

Aim: To evaluate the success and safety of MicroPulse transscleral laser therapy (TLT) on intraocular pressure (IOP) reduction in adults with uncontrolled glaucoma using different total treatment durations, sweep velocities, and a number of sweeps utilizing the revised MicroPulse P3 delivery device. Materials and methods: A single-center Institutional Review Board (IRB) approved multiple cohort studies of MicroPulse TLT with the revised MicroPulse P3 delivery device, which was conducted in 61 eyes from 40 adults with uncontrolled glaucoma. Eyes that received 50-second (GI, GII, and GIII) and 60-second (GIV, GV, and GVI) treatment applications between May and October 2020 were reviewed. Each hemisphere received a total of five, four, or three sweeps. The patient's IOP and glaucoma medications were monitored over 12 months follow-up. Qualified success was defined as an IOP of ≤21 mm Hg and/or reduction of ≥20% from baseline at 12 months, with no secondary glaucoma reinterventions. Complete success was defined as meeting the above criteria with no increase in glaucoma medications at 12 months. All eyes requiring a glaucoma surgical intervention were considered a failure. Results: Qualified success was achieved in 83.6% of eyes, while complete success was achieved in 75.4% of eyes. In eyes receiving 50-second applications of five, four, or three sweeps (GI, GII, and GIII), 70, 90, and 91% achieved qualified success, respectively; in eyes receiving 60-second applications of five, four, or three sweeps (GIV, GV, and GVI), 78, 82, and 90% achieved qualified success, respectively. Within each subgroup, mean IOP reductions ranged from 32.8 to 49.4% and were statistically significant (p < 0.008). The failure rate was 16.4%, and at least one eye failed in each subgroup. Conclusions: MicroPulse TLT with the revised MicroPulse P3 delivery device and relatively low total energy levels is safe and effective at lowering IOP. Efficacy appears to increase with longer treatment durations and slower sweep velocities, but statistical differences between age and clinical differences between baseline IOP measurements limit comparison between subgroups. Clinical significance: There is a lack of literature evaluating the safety and IOP-lowering success of the revised MicroPulse P3 delivery device using different total treatment durations, sweep velocities, and number of sweeps. How to cite this article: Checo LA, Dorairaj S, Wagner IV, et al. Clinical Outcomes of MicroPulse Transscleral Laser Therapy with the Revised P3 Delivery Device. J Curr Glaucoma Pract 2024;18(1):10-15.

2.
J Clin Med ; 12(7)2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37048717

RESUMEN

BACKGROUND: This study aimed to assess the pain experienced during micropulse transscleral laser therapy (MPTLT) and overnight thereafter and explore the factors associated with the pain. METHODS: This prospective study included 100 eyes of 81 glaucoma patients undergoing MPTLT under retrobulbar anesthesia. All patients were asked to rate both types of pain using a numerical rating scale (NRS). The risk factors were explored using multivariable mixed-effects ordinal logistic regression. RESULTS: The mean (SD) NRS pain score during the procedure was 3.57 (3.41) (range 0-10), which included no, mild, moderate, and severe pain in 30 (30%), 33 (33%), 17 (17%), and 20 (20%) eyes, respectively. The mean (SD) NRS score of overnight pain was 2.99 (2.28) (range 0-9), which included no, mild, moderate, and severe pain in 17 (17%), 59 (59%), 17 (17%), and 7 (7%) eyes, respectively. Twenty-seven (27%) eyes reported worse pain overnight than during the procedure. Increased age, initial intraocular pressure, and pain during the procedure were significantly associated with increased overnight pain (p < 0.05). CONCLUSIONS: Up to a fourth of eyes had worse pain after discharge. Older age, initial intraocular pressure, and pain during the procedure were risk factors for higher levels of overnight pain.

3.
Am J Ophthalmol Case Rep ; 23: 101190, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34409197

RESUMEN

PURPOSE: To report a case of ciliary body metastasis with uncontrolled glaucoma that was successfully treated with micropulse transscleral laser therapy (MPTLT). OBSERVATIONS: A case of a 44-year-old female with uncontrolled glaucoma secondary to ciliary body metastasis from pulmonary adenocarcinoma. Antiglaucoma medications, intravitreal ranibizumab injection and local radiotherapy were ineffective in reducing her intraocular pressure (IOP) and ocular pain. MPTLT using a power setting of 2,000 mW, 31.3% duty cycle, and 140 seconds over 180 degrees demonstrated favorable IOP reduction (from 31 to 8 mmHg) on the first postoperative day without either ocular pain or postoperative complications. IOP remained controlled until she died from hemoperitoneum 18 days after hospital discharge. CONCLUSIONS AND IMPORTANCE: MPTLT can be a safe and effective procedure for IOP control in intraocular metastasis patients with uncontrolled glaucoma.

4.
Int Med Case Rep J ; 13: 631-636, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33223857

RESUMEN

PURPOSE: To report the efficacy and safety of MicroPulse transscleral laser therapy (TLT) and Kahook Dual Blade excisional goniotomy and goniosynechialysis combined with phacoemulsification for chronic angle-closure glaucoma (ACG). PATIENTS AND METHODS: A 39-year-old hyperopic female with a known history of ACG presented with a 2-week history of blurry vision, headache, and photophobia in the right eye (RE) following surgical peripheral iridectomy at another hospital. On examination, her uncorrected visual acuity was 20/50 in the RE, and 20/25 in the left eye (LE). Goldman applanation tonometry revealed an intraocular pressure (IOP) of 51 mmHg in the RE and 12 mmHg in the LE. Ocular examination of the RE revealed conjunctival hyperemia, corneal edema, shallow anterior chamber, posterior synechia, mid-dilated non-reactive pupil, and early cataractous changes. Anterior segment examination findings in the LE were normal except for a shallow anterior chamber. Gonioscopy revealed a closed angle (Schaffer grade 0) with 360° peripheral anterior synechia in the RE and a narrow angle (Schaffer grade 2) in the LE. The cup-to-disc ratios were 0.5 RE and 0.3 LE. The patient underwent MicroPulse TLT with phacoemulsification, Kahook Dual Blade-assisted goniosynechialysis, and excisional goniotomy in the RE. RESULTS: At the 1-year follow-up, her IOP remained stable without the need for antiglaucoma medications. No further optic nerve or visual field deterioration was noted. CONCLUSION: MicroPulse TLT combined with phacoemulsification and Kahook Dual Blade-assisted goniosynechialysis and excisional goniotomy safely reduced IOP and the need for antiglaucoma medications in chronic ACG, avoiding the complications associated with incisional glaucoma surgery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA