1.
J Am Heart Assoc ; 12(16): e030480, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37577948

RESUMEN

Background Coronary flow reserve (CFR) and microvascular resistance reserve (MRR) are physiological parameters to assess coronary microvascular dysfunction. CFR and MRR can be assessed using bolus or continuous thermodilution, and the correlation between these methods has not been clarified. Furthermore, their association with angina and quality of life is unknown. Methods and Results In total, 246 consecutive patients with angina and nonobstructive coronary arteries from the multicenter Netherlands Registry of Invasive Coronary Vasomotor Function Testing (NL-CFT) were investigated. The 36-item Short Form Health Survey Quality of Life and Seattle Angina questionnaires were completed by 153 patients before the invasive measurements. CFR and MRR were measured consecutively with bolus and continuous thermodilution. Mean continuous thermodilution-derived coronary flow reserve (CFRabs) was significantly lower than mean bolus thermodilution-derived coronary flow reserve (CFRbolus) (2.6±1.0 versus 3.5±1.8; P<0.001), with a modest correlation (ρ=0.305; P<0.001). Mean continuous thermodilution-derived microvascular resistance reserve (MRRabs) was also significantly lower than mean bolus thermodilution-derived MRR (MRRbolus) (3.1±1.1 versus 4.2±2.5; P<0.001), with a weak correlation (ρ=0.280; P<0.001). CFRbolus and MRRbolus showed no correlation with any of the angina and quality of life domains, whereas CFRabs and MRRabs showed a significant correlation with physical limitation (P=0.005, P=0.009, respectively) and health (P=0.026, P=0.012). In a subanalysis in patients in whom spasm was excluded, the correlation further improved (MRRabs versus physical limitation: ρ=0.363; P=0.041, MRRabs versus physical health: ρ=0.482; P=0.004). No association with angina frequency and stability was found. Conclusions Absolute flow measurements using continuous thermodilution to calculate CFRabs and MRRabs weakly correlate with, and are lower than, the surrogates CFRbolus and MRRbolus. Absolute flow parameters showed a relationship with physical complaints. No relationship with angina frequency and stability was found.


Asunto(s)
Calidad de Vida , Termodilución , Humanos , Termodilución/métodos , Circulación Coronaria/fisiología , Angina de Pecho/diagnóstico , Corazón , Vasos Coronarios , Microcirculación/fisiología
2.
J Am Heart Assoc ; 12(13): e030285, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345805

RESUMEN

Background ST-segment-elevation myocardial infarction complicated with no reflow after primary percutaneous coronary intervention is associated with adverse outcomes. Although several hyperemic drugs have been shown to improve the Thrombolysis in Myocardial Infarction flow, optimal treatment of no reflow remains unsettled. Saline infusion at 20 mL/min via a dedicated microcatheter causes (flow-mediated) hyperemia. The objective is to compare the efficacy of pharmacologic versus flow-mediated hyperemia in patients with ST-segment-elevation myocardial infarction complicated with no reflow. Methods and Results In the RAIN-FLOW (Treatment of Slow-Flow After Primary Percutaneous Coronary Intervention With Flow-Mediated Hyperemia) study, 67 patients with ST-segment-elevation myocardial infarction and no reflow were randomized to receive either pharmacologic-mediated hyperemia with intracoronary adenosine or nitroprusside (n=30) versus flow-mediated hyperemia (n=37). The angiographic corrected Thrombolysis in Myocardial Infarction frame count and the minimal microcirculatory resistance, as assessed with intracoronary pressure-thermistor wire, dedicated microcatheter, and thermodilution techniques, were compared after study interventions. Both Thrombolysis in Myocardial Infarction frame count(40.2±23.1 versus 39.2±20.7; P=0.858) and minimal microcirculatory resistance (753.6±661.5 versus 993.3±740.8 Wood units; P=0.174) were similar between groups. Thrombolysis in Myocardial Infarction 3 flow was observed in 26.7% versus 27.0% (P=0.899). Flow-mediated hyperemia showed 2 different thermodilution patterns during saline infusion indicative of the severity of the no reflow phenomenon. In-hospital death and nonfatal heart failure were observed in 10.4% and 26.9%, respectively. Conclusions Both treatments showed similar (and limited) efficacy restoring coronary flow. Flow-mediated hyperemia with thermodilution pattern assessment allowed the simultaneous characterization of the no reflow degree and response to hyperemia. No reflow was associated with a high rate of adverse outcomes. Further research is warranted to prevent and to treat no reflow in patients with ST-segment-elevation myocardial infarction. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04685941.


Asunto(s)
Hiperemia , Infarto del Miocardio , Fenómeno de no Reflujo , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Resultado del Tratamiento , Microcirculación , Mortalidad Hospitalaria , Hiperemia/etiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio con Elevación del ST/complicaciones , Fenómeno de no Reflujo/etiología , Angiografía Coronaria/efectos adversos
3.
JACC Cardiovasc Interv ; 16(4): 470-481, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858668

RESUMEN

BACKGROUND: Microvascular resistance reserve (MRR) is a new index to assess coronary microvascular (dys)function, which can be easily measured invasively using continuous thermodilution. In contrast to coronary flow reserve (CFR), MRR is independent of epicardial coronary disease and hemodynamic variations. Its measurement is accurate, reproducible, and operator independent. OBJECTIVES: The aim of this study was to establish the range of normal values for MRR and to determine an optimal cutoff point. METHODS: In this exploratory study in 214 patients with angina and no obstructive coronary artery disease, after excluding significant epicardial disease, all physiological parameters, such as fractional flow reserve, index of microvascular resistance, CFR, absolute blood flow, absolute microvascular resistance, and MRR, were measured. On the basis of concordant positive or concordant negative results of index of microvascular resistance and CFR, subgroups of patients were defined with high probability of either normal (n = 122) or abnormal (n = 24) microcirculatory function, and MRR was studied in these groups. RESULTS: Mean MRR in the "normal" group was 3.4 compared with a mean MRR of 1.9 in the "abnormal" group; these values were significantly different between the groups. MRR >2.7 ruled out coronary microvascular dysfunction (CMD) with a certainty of 96%, whereas MRR <2.1 indicated the presence of CMD with a similar high certainty of 96%. CONCLUSIONS: MRR is a suitable index to distinguish the presence or absence of CMD in patients with angina and no obstructive coronary artery disease. The present data indicate that an MRR of 2.7 virtually excludes the presence of CMD, while an MRR value <2.1 confirms its presence.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Humanos , Microcirculación , Resultado del Tratamiento , Angina de Pecho
4.
Br J Cardiol ; 29(2): 13, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36212789

RESUMEN

Imagine that it is possible to know, the actual coronary blood flow. Would this not remove any doubt, if a chest pain is the heart's fault?

5.
J Am Coll Cardiol ; 78(14): 1471-1479, 2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-34593129

RESUMEN

Coronary microvascular dysfunction is a highly prevalent condition of both structural and functional coronary disorders in patients with angina and nonobstructive coronary artery disease (ANOCA). Current diagnostic modalities to assess microvascular function are related to prognosis, but these modalities have several technical shortcomings and lack the opportunity to determine true coronary blood flow and microvascular resistance. Intracoronary continuous thermodilution assessment of absolute coronary flow (Q) and microvascular resistance (R) was recently shown to be safe and feasible in ANOCA. Further exploration and implementation could lead to a better understanding and treatment of patients with ANOCA. This review discuss the coronary pathophysiology of microvascular dysfunction, provides an overview of noninvasive and invasive diagnostics, and focuses on the novel continuous thermodilution method. Finally, how these measurements of absolute Q and R could be integrated and how this would affect future clinical care are discussed.


Asunto(s)
Circulación Coronaria , Enfermedad Coronaria/diagnóstico , Técnicas de Diagnóstico Cardiovascular , Microcirculación , Angina de Pecho/fisiopatología , Enfermedad Coronaria/etiología , Vasos Coronarios/fisiopatología , Humanos , Microvasos/fisiopatología , Termodilución
7.
J Am Coll Cardiol ; 77(6): 728-741, 2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33573743

RESUMEN

BACKGROUND: Intracoronary continuous thermodilution is a novel technique to quantify absolute coronary flow (Q) and resistance (R) and has potential advantages over current methods such as coronary flow reserve (CFR) and index of microvascular resistance (IMR). However, no data are available in patients with ischemia and nonobstructive coronary artery disease (INOCA). OBJECTIVES: This study aimed to assess the relationship of Q and R with the established CFR/IMR in INOCA patients, to explore the potential of absolute Q, and to predict self-reported angina. METHODS: Consecutive INOCA patients (n = 84; 87% women; mean age 56 ± 8 years) underwent coronary function testing, including acetylcholine (ACH) provocation testing, adenosine (ADE) testing (CFR/IMR), and continuous thermodilution (absolute Q and R) with saline-induced hyperemia. RESULTS: ACH testing was abnormal (ACH+) in 87%, and ADE testing (ADE+) in 38%. The median absolute Q was 198 ml/min, and the median absolute R was 416 WU. The absolute R was higher in patients with ADE+ versus ADE- (495 WU vs. 375 WU; p = 0.04) but did not differ between patients with ACH+ versus ACH- (421 WU vs. 409 WU; p = 0.74). Low Q and high R were associated with severe angina (odds ratio: 3.09; 95% confidence interval: 1.16 to 8.28; p = 0.03; and odds ratio: 2.60; 95% confidence interval: 0.99 to 6.81; p = 0.05), respectively. CONCLUSIONS: In this study, absolute R was higher in patients with abnormal CFR/IMR, whereas both Q and R were unrelated to coronary vasospasm. Q and R were associated with angina, although their exact predictive value should be determined in larger studies.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria/fisiología , Termodilución , Acetilcolina , Adenosina , Angina Inestable/fisiopatología , Vasoespasmo Coronario/fisiopatología , Femenino , Humanos , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Sistema de Registros , Resistencia Vascular/fisiología , Vasodilatadores
SELECCIÓN DE REFERENCIAS