Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 327
Filtrar
1.
Anal Chim Acta ; 1318: 342953, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39067928

RESUMEN

BACKGROUND: Developing biosensors with antifouling properties is essential for accurately detecting low-concentration biomarkers in complex biological matrix, which is imperative for effective disease diagnosis and treatment. Herein, an antifouling electrochemical aptasensor qualifying for probing targets in human serum was explored based on newly-devised peptides that could form inverted U-shaped structures with long-term stability. RESULTS: The inverted U-shaped peptides (U-Pep) with two terminals of thiol groups grafted onto the Au-modified electrode showcase superior antifouling properties in terms of high stability against enzymatic hydrolysis and long acting against biofouling in actual biofluids. The construction of the outlined antifouling electrochemical aptasensor just involved the fabrication of Au-deposited poly(3,4 ethylenedioxythiophene) (Au/PEDOT) modified electrode, followed by one-step co-incubation in the peptides and the aptamer probes with the Au/PEDOT electrode. Taking a typical biomarker of alpha-fetoprotein (AFP) for detection, this elegant antifouling aptasenor demonstrated a nice response for probing the target AFP with a low detection limit of 0.27 pg/mL and a wide linear scope of 1.0 pg/mL to 1.0 µg/mL, and furthermore qualified for assaying of AFP in human serum samples with satisfactory accuracy and feasibility. SIGNIFICANCE: This engineering strategy of U-Pep with long-lasting antifouling efficacy opens a new horizon for high-performance antifouling biosensors suitable for detection in complex bifluids, and it could spark more inspiration for a follow-up exploration of other featured antifouling biomaterials.


Asunto(s)
Aptámeros de Nucleótidos , Incrustaciones Biológicas , Técnicas Biosensibles , Técnicas Electroquímicas , Oro , Péptidos , Humanos , Técnicas Biosensibles/métodos , Péptidos/química , Oro/química , Aptámeros de Nucleótidos/química , Incrustaciones Biológicas/prevención & control , Electrodos , Polímeros/química , alfa-Fetoproteínas/análisis , Límite de Detección , Compuestos Bicíclicos Heterocíclicos con Puentes
2.
Foods ; 13(14)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39063260

RESUMEN

A novel electrochemical aptasensor was prepared for the simultaneous determination of aflatoxin B1 (AFB1) and ochratoxin A (OTA). Composites of Au nanoparticles and polyethyleneimine-reduced graphene oxide (AuNPs/PEI-RGO) with good electrical conductivity and high specific surface area were employed as the supporting substrate, demonstrating the ability to provide more binding sites for aptamers and accelerate the electron transfer. Aptamers were immobilized on a AuNPs/PEI-RGO surface to specifically recognize AFB1 and OTA. A metal-organic framework of UiO-66-NH2 served as the signal carrier to load metal ions of Cu2+ and Pb2+, which facilitated the generation of independent current peaks and effectively improved the electrochemical signals. The prepared aptasensor exhibited sensitive current responses for AFB1 and OTA with a linear range of 0.01 to 1000 ng/mL, with detection limits of 6.2 ng/L for AFB1 and 3.7 ng/L for OTA, respectively. The aptasensor was applied to detect AFB1 and OTA in cereal samples, achieving results comparable with HPLC-MS, with recovery results from 92.5% to 104.1%. With these merits of high sensitivity and good selectivity and stability, the prepared aptasensor proved to be a powerful tool for evaluating contaminated cereals.

3.
ACS Sens ; 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39031767

RESUMEN

Homocysteine (Hcy) and C-reactive protein (CRP) are critical biomarkers for numerous chronic diseases, with cardiovascular disease (CVD) being the most prevalent. The ability to simultaneously detect both biomarkers in point-of-care settings is in high demand for CVD early diagnosis and prevention. Herein, we prepared the eutectic gallium indium (EGaIn) nanoparticles decorated with p-phenylenediamine (PPD) on the surface to facilitate the subsequent attachment of gold nanoparticles (AuNPs) to achieve EGaIn-PPD@Au, which was modified on the screen-printed electrochemical paper-based analytical devices (ePADs). Aptamers that are specific to Hcy and CRP were then immobilized on the EGaIn-PPD@Au surface to achieve the sensing interface on ePADs. The presence of EGaIn-PPD@Au significantly enhanced the electrical conductivity, leading to amplified electrochemical signals. This aptasensor demonstrated high specificity, capable of detecting Hcy in a range of 1-50 µM with a detection limit of 0.22 µM, and the detection range for CRP was 1-100 ng/mL with a detection limit of 0.039 ng/mL. The aptasensor also effectively detected Hcy and CRP in clinical saliva samples, yielding an area under the curve (AUC) of about 0.80 when the individual biomarker was considered and 0.93 when both biomarkers were taken into account. The positive correlation observed between salivary and blood concentrations of Hcy and CRP, coupled with their association with cardiovascular disease (CVD), suggested the potential of this methodology as a noninvasive point-of-care strategy for the early diagnosis of CVD.

4.
J Colloid Interface Sci ; 672: 236-243, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38838631

RESUMEN

This study reports the development of a photocatalytic electrochemical aptasensor for the purpose of detecting chloramphenicol (CAP) antibiotic residues in water by utilizing SYBR Green I (SG) and chemically exfoliated MoS2 (ce-MoS2) as synergistically signal-amplification platforms. The Au nanoparticles (AuNPs) were electrodeposited onto the surface of an indium tin oxide (ITO) electrode. After that, the thiolate-modified cDNA, also known as capture DNA, was combined with the aptamer. Subsequently, photosensitized SG molecules and ce-MoS2 nanomaterial were inserted into the groove of the resultant double-stranded DNA (dsDNA). The activation of the photocatalytic process upon exposure to light resulted in the generation of singlet oxygen. The singlet oxygen effectively split the dsDNA, resulting in significant enhancement in the current of [Fe(CN)6]3-/4-. When the CAP was present, both SG molecules and ce-MoS2 broke away from the dsDNA, which turned off the photosensitization response, leading to significant reduction in the current of [Fe(CN)6]3-/4-. Under the optimal conditions, the aptasensor exhibited a linear relationship between the current of [Fe(CN)6]3-/4- with logarithmic concentrations of CAP from 20 to 1000 nM, with a detection of limit (3σ) of 3.391 nM. The aptasensor also demonstrated good selectivity towards CAP in the presence of interfering antibiotics, such as tetracycline, streptomycin, levofloxacin, ciprofloxacin, and sulfadimethoxine. Additionally, the results obtained from the analysis of natural water samples using the proposed aptasensor were consistent with the findings acquired through the use of a liquid chromatograph-mass spectrometer. Therefore, with its simplicity and high selectivity, this aptasensor can potentially detect alternative antibiotics in environmental water samples by replacing the aptamers based on photosensitization.


Asunto(s)
Aptámeros de Nucleótidos , Benzotiazoles , Técnicas Biosensibles , Cloranfenicol , Diaminas , Disulfuros , Técnicas Electroquímicas , Molibdeno , Compuestos Orgánicos , Quinolinas , Cloranfenicol/análisis , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Molibdeno/química , Diaminas/química , Disulfuros/química , Benzotiazoles/química , Quinolinas/química , Compuestos Orgánicos/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Oro/química , Fármacos Fotosensibilizantes/química , Antibacterianos/análisis , Límite de Detección , Contaminantes Químicos del Agua/análisis , Procesos Fotoquímicos , Tamaño de la Partícula
5.
Talanta ; 278: 126450, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38908138

RESUMEN

In response to the pressing need for highly efficient simultaneous detection of multiple mycotoxins, which are often found co-occurring in food raw materials and feed, an MXene-based electrochemical aptasensor array (MBEAA) was developed. This aptasensor array utilizes high-specificity aptamers as recognition elements, enabling the capture of electrical signal changes in the presence of target mycotoxins. Based on this platform, a multi-channel portable electrochemical device, enabling rapid, cost-effective, and simultaneous detection of aflatoxin B1 (AFB1), ochratoxin A (OTA), and zealenone (ZEN) was further developed. The developed system boasts a wide detection range of 1.0 × 10-1 to 10.0 ng mL-1, with remarkable performance characterized by ultra-low detection limits of 41.2 pg mL-1, 27.6 pg mL-1, and 33.0 pg mL-1 for AFB1, OTA, and ZEN, respectively. Successfully applied in corn samples, this method offers a portable, easy-to-operate, and cost-effective solution for simultaneous multi-mycotoxin detection. Moreover, the application of the self-developed detection system could be expanded for simultaneous detection of many different targets when their specific aptamers or antibodies were available.


Asunto(s)
Aflatoxina B1 , Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Micotoxinas , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Micotoxinas/análisis , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Aflatoxina B1/análisis , Zea mays/química , Límite de Detección , Ocratoxinas/análisis
6.
Bioelectrochemistry ; 160: 108767, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38878458

RESUMEN

Golgi protein 73 (GP73) is a novel tumor marker in the early diagnosis and prognosis of hepatocellular carcinoma (HCC). Herein, a competitive electrochemical aptasensor for detecting GP73 was constructed using reduced graphene oxide-ferrocene-polyaniline nanocomposite (rGO-Fc-PANi) as the biosensing platform. The rGO-Fc-PANi had larger specific surface area, excellent conductivity and outstanding electroactive performance, which served as nanocarrier for GP73 aptamer (GP73Apt) binding and as redox nanoprobe for record electrical signal. Then, a complementary chain (cDNA) was fixed to the electrode by hybridization with GP73Apt. When GP73 was present, a competitive process happened among cDNA, GP73Apt and GP73, formed the GP73-GP73Apt stable chemical structure and made cDNA detach from the sensing electrode, resulting in enhancement of electrical signal. The difference in the corresponding peak current before and after the competition can be used to indicate the quantitative of GP73. Under optimal conditions, the DPV current response showed a good log-linear relationship with GP73 concentrations (0.001 âˆ¼ 100.0 ng/mL) with a detection limit of 0.15 pg/mL (S/N = 3). It was successfully used for GP73 detection in human serum with RSDs ranging from 1.08 % to 6.96 %. Therefore, the aptasensor could provide an innovative technology platform and hold a great potential in clinical application.

7.
Bioelectrochemistry ; 160: 108750, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38852385

RESUMEN

Overuse of enrofloxacin (ENR) has posed a potential threat to ecosystems and public health, so it is critical to sensitive and accurate determination of ENR residues. In this work, a novel ultra-sensitive and specific electrochemical aptasensor was fabricated based on the cobalt diselenide loaded gold and platinum nanoflowers (Au@Pt NFs/ CoSe2) and Exonuclease III (Exo III)-assisted cycle amplification strategy for the detection of ENR. Au@Pt NFs/ CoSe2 nanosheets as the substrate material, with large surface area, accelerate electron transfer and attach more DNA probes on the electrode substrate, have effectively enhanced the electrochemical performance of the electrode. With the existence of Enrofloxacin (ENR), the aptamer recognizes and binds to ENR, thus the signal probe cDNA was released and immobilized onto the electrode surface to hybridized with methylene blue (MB) labelled DNA (MB-DNA), thereby triggering the Exo III-assisted cycle for further signal amplification. As expected, the prepared aptasensor demonstrated excellent sensitivity and selectivity, with a wide linear range from 5.0 × 10-6 ng/mL to 1.0 × 10-2 ng/mL for ENR, a low detection limit of 1.59 × 10-6 ng/mL. Consequently, this strategy provided a promising avenue for ultrasensitive and accurate detection of ENR in milk samples.

8.
Mikrochim Acta ; 191(7): 413, 2024 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-38904692

RESUMEN

Hepatocellular carcinoma (HCC) is the most common liver malignancy and is characterized by increasing incidence and high mortality rates. Current methods for the screening and diagnosis of HCC exhibit inherent limitations, highlighting the ever-growing need for the development of new methods for the early diagnosis of HCC. The aim of this work was to develop a novel electrochemical aptasensor for the detection of HepG2 cells, a type of circulating tumor cells that can be used as biomarkers for the early detection of HCC. A carbon screen-printed electrode was functionalized with a composite suspension containing graphene oxide, chitosan, and polyaniline nanoparticles to increase the electrode surface and provide anchoring sites for the HepG2 cell-specific aptamer. The aptamer was immobilized on the surface of the functionalized electrode using multipulse amperometry, an innovative technique that significantly reduces the time required for aptamer immobilization. The innovative platform was successfully employed for the first time for the amplification-free detection of HepG2 cells in a linear range from 10 to 200,000 cells/mL, with a limit of detection of 10 cells/mL. The platform demonstrated high selectivity and stability and was successfully used for the detection of HepG2 cells in spiked human serum samples with excellent recoveries.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Carcinoma Hepatocelular , Técnicas Electroquímicas , Grafito , Neoplasias Hepáticas , Humanos , Células Hep G2 , Aptámeros de Nucleótidos/química , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/sangre , Técnicas Electroquímicas/métodos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/sangre , Grafito/química , Técnicas Biosensibles/métodos , Límite de Detección , Compuestos de Anilina/química , Electrodos , Quitosano/química
9.
Talanta ; 276: 126281, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38788386

RESUMEN

In the medical field, changes in interleukin-6 (IL-6) concentration serve as essential biomarkers for monitoring and diagnosing various conditions, including acute inflammatory responses such as those seen in trauma and burns, and chronic illnesses like cancer. This paper detailed a label-free electrochemical aptamer sensor designed for IL-6 quantification. A composite material consisting of Ti3C2Tx and MoS2 was successfully synthesized to fabricate this sensor. The synergistic effect of MoS2's catalytic action on hydrogen peroxide (H2O2), used as a signalling marker, when combined with the exceptional conductivity and large specific surface area of Ti3C2Tx, not only enables an increased loading of MoS2 but also significantly boosts the electrochemical response. The in situ-reduced Au NPs provided stable immobilization sites for DNA aptamers (DNAapt) and facilitated electron transfer, ensuring accurate IL-6 recognition. Under optimal conditions, the aptamer sensor exhibited a wide linear range (5 pg/mL to 100 ng/mL) and a low limit of detection (LOD) of 2.9 pg/mL. Its sensing performance in human serum samples highlights its potential as a promising clinical analysis tool.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Interleucina-6 , Nanopartículas del Metal , Humanos , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Disulfuros/química , Técnicas Electroquímicas/métodos , Oro/química , Peróxido de Hidrógeno/química , Interleucina-6/sangre , Interleucina-6/análisis , Límite de Detección , Nanopartículas del Metal/química , Molibdeno/química , Titanio/química
10.
Angew Chem Int Ed Engl ; 63(32): e202402808, 2024 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-38764376

RESUMEN

Multimeric aptamers have gained more attention than their monomeric counterparts due to providing more binding sites for target analytes, leading to increased affinity. This work attempted to engineer the surface-based generation of multimeric aptamers by employing the room temperature rolling circle amplification (RCA) technique and chemically modified primers for developing a highly sensitive and selective electrochemical aptasensor. The multimeric aptamers, generated through surface RCA, are hybridized to modified spacer primers, facilitating the positioning of the aptamers in the proximity of sensing surfaces. These multimeric aptamers can be used as bio-receptors for capturing specific targets. The surface amplification process was fully characterized, and the optimal amplification time for biosensing purposes was determined, using SARS-CoV-2 spike protein (SP). Interestingly, multimeric aptasensors produced considerably higher response signals and affinity (more than 10-fold), as well as higher sensitivity (almost 4-fold) compared to monomeric aptasensors. Furthermore, the impact of surface structures on the response signals was studied by utilizing both flat working electrodes (WEs) and nano-/microislands (NMIs) WEs. The NMIs multimeric aptasensors showed significantly higher sensitivity in buffer and saliva media with the limit of detection less than 2 fg/ml. Finally, the developed NMIs multimeric aptasensors were clinically challenged with several saliva patient samples.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Técnicas de Amplificación de Ácido Nucleico , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/genética , Conformación de Ácido Nucleico , Propiedades de Superficie , ADN Circular/química , ADN Circular/genética , Amplificación de Genes , Humanos , COVID-19/diagnóstico , COVID-19/virología , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Glicoproteína de la Espiga del Coronavirus/genética
11.
Anal Chim Acta ; 1309: 342685, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38772667

RESUMEN

The monitoring of heavy metal ions in ocean is crucial for environment protection and assessment of seawater quality. However, the detection of heavy metal ions in seawater with electrochemical sensors, especially for long-term monitoring, always faces challenges due to marine biofouling caused by the nonspecific adsorption of microbial and biomolecules. Herein, an electrochemical aptasensor, integrating both antifouling and antibacterial properties, was developed for the detection of Hg2+ in the ocean. In this electrochemical aptasensor, eco-friendly peptides with superior hydrophilicity served as anti-biofouling materials, preventing nonspecific adsorption on the sensing interface, while silver nanoparticles were employed to eliminate bacteria. Subsequently, a ferrocene-modified aptamer was employed for the specific recognition of Hg2+, leveraging the aptamer's ability to fold into a thymine-Hg2+-thymine (T-Hg2+-T) structure upon interaction, and bringing ferrocene nearer to the sensor surface, significantly amplifying the electrochemical response. The prepared electrochemical aptasensor significantly reduced the nonspecific adsorption in seawater while maintaining sensitive electrochemical response. Furthermore, the biosensor exhibited a linear response range of 0.01-100 nM with a detection limit of 2.30 pM, and realized the accurate monitoring of mercury ions in real marine environment. The research results offer new insights into the preparation of marine antifouling sensing devices, and it is expected that sensors with antifouling and antimicrobial capabilities will find broad applications in the monitoring of marine pollutants.


Asunto(s)
Antibacterianos , Incrustaciones Biológicas , Técnicas Biosensibles , Técnicas Electroquímicas , Mercurio , Agua de Mar , Mercurio/análisis , Agua de Mar/química , Agua de Mar/microbiología , Técnicas Electroquímicas/métodos , Antibacterianos/análisis , Antibacterianos/farmacología , Técnicas Biosensibles/métodos , Incrustaciones Biológicas/prevención & control , Aptámeros de Nucleótidos/química , Plata/química , Contaminantes Químicos del Agua/análisis , Nanopartículas del Metal/química , Límite de Detección , Compuestos Ferrosos/química , Metalocenos
12.
Mikrochim Acta ; 191(6): 340, 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38787447

RESUMEN

A new sandwich-type electrochemical biosensing platform was developed by gold @polyphthalenediamine nanohybrids (AuNP@PoPD) as the sensing platform and phosphorus doped reduced graphene oxide-hemin-palladium nanoparticles (PrGO-Hemin-PdNP) as the signal amplifier for phosphatidylinositol proteoglycan 3 (GPC3). AuNP@PoPD, co-electrodeposited into the screen printed electrode with high conductivity and stability, is dedicated to assembling the primary GPC3 aptamer (GPC3Apt). The second GPC3Apt immobilized on the high conductivity and large surface area of PrGO-Hemin-PdNP was utilized as an electrochemical signal reporter by hemin oxidation (PrGO-Hemin-PdNP-GPC3Apt). In the range 0.001-10.0 ng/mL, the hemin oxidation current signal of the electrochemical aptasensor increased log-linearly with the concentration of GPC3, the lowest detection limit was 0.13 pg/mL, and the sensitivity was 2.073 µA/µM/cm2. The aptasensor exhibited good sensing performance in a human serum sample with the relative error of 4.31-8.07%. The sandwich sensor showed good selectivity and stability for detection GPC3 in human serum samples, providing a new efficient and sensitive method for detecting HCC markers.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Glipicanos , Oro , Grafito , Hemina , Límite de Detección , Nanopartículas del Metal , Paladio , Glipicanos/sangre , Humanos , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Aptámeros de Nucleótidos/química , Hemina/química , Grafito/química , Paladio/química , Oro/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Electrodos
13.
Mikrochim Acta ; 191(6): 358, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38819654

RESUMEN

A signal-amplified platform was designed to construct a label-free electrochemical aptasensor for lead ions (Pb2+) assay. First, flower-like molybdenum disulfide-supported AuNPs (AuNPs@MoS2) nanocomposites were synthesized and used as substrates for modifying the electrode. The AuNPs@MoS2 material possessed large surface area and superior biocompatibility, which was beneficial to improve the loading amount of the complementary DNA (cDNA) and amplified the response signal. Importantly, the prepared core-shell Pt@Pd bimetallic nanoparticles (Pt@PdNPs) were used to conjugate with redox marker thionine (Thi) and aptamer (Apt) for further signal amplification; the obtained signal probes (Thi-Pt@PdNPs-Apt) were connected by the cDNA assembled on the electrode through DNA hybridization. Differential pulse voltammetry was performed to monitor the signal of Thi. After incubating of aptasensor with Pb2+, the specific recognition of Pb2+ and Apt resulted in the dissociation of aptamer-cDNA complex, thereby the Thi-Pt@PdNPs-Apt separated from the electrode surface and decreased current response was obtained. The prepared electrochemical sensor exhibited linear response to Pb2+ in the range 5.0 × 10-4-100 nM and a detection limit of 1.0 × 10-4 nM was achieved. The sensor was applied to the determination of Pb2+ in actual sample with high sensitivity and accuracy, demonstrating potential applications in heavy metal monitoring.

14.
Talanta ; 276: 126250, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38743969

RESUMEN

In this research, self-screening aptamer and MOFs-derived nanomaterial have been combined to construct electrochemical aptasensor for environmental detection. By utilizing the large specific surface area of reduced graphene oxide (rGO), ZIF-8 was grown in situ on surface of rGO, and the composites was pyrolyzed to obtain MOFs-derived porous carbon materials (rGO-NCZIF). Thanks to the synergistic effect between rGO and NCZIF, the complex exhibits remarkable characteristics, including a high electron transfer rate and electrocatalytic activity. In addition, the orderly arrangement of imidazole ligands within ZIF-8 facilitated the uniform doping of nitrogen elements into the porous carbon, thereby significantly enhancing its electrochemical performance. After carboxylation, rGO-NCZIF was functionalized with self-screening aptamer for fabricating electrochemical aptasensor, which can be used to detect Erwinia cypripedii, a kind of quarantine plant bacteria, with detection limit of 4.92 × 103 cfu/mL. Due to the simplicity and speed, the aptasensor is suitable for rapid customs inspection and quarantine. Additionally, the universality of this sensing strategy was verified through exosomes detection by changing the aptamer. The results indicated that the rGO-NCZIF-based electrochemical aptasensor had practical value in the environmental and medical fields.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Grafito , Estructuras Metalorgánicas , Grafito/química , Aptámeros de Nucleótidos/química , Estructuras Metalorgánicas/química , Técnicas Electroquímicas/métodos , Porosidad , Técnicas Biosensibles/métodos , Carbono/química , Imidazoles/química , Límite de Detección
15.
Talanta ; 276: 126260, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759364

RESUMEN

Lead ion pollution has become a serious public health concern worldwide. Therefore, sensitive detection of Pb2+ is critical to control lead pollution, assess risks, and safeguard the health of vulnerable populations. This study reports a highly sensitive labelling-free electrochemical aptasensor for Pb2+ detection. The aptasensor employs silver-platinum nanoparticles/graphene oxide (AgPt/GO) and Exonuclease III (Exo III) for signal amplification. GO provides high surface area and conductivity for immobilizing AgPt NPs, facilitating the immobilization of aptamer (Apt) probes on the electrode surface. Exo III enzymatically cleaves DNA strands on the electrode surface, releasing DNA segments to amplify the signal further. The synergistic amplification by AgPt/GO and ExoIII enables an extremely wide linear detection range of 0.05 pM-5 nM for Pb2+, with a low detection limit of 0.019 pM. Additionally, the G-quadruplex structure ensures excellent selectivity for Pb2+ detection, resulting in high reproducibility and stability of the aptasensor. The aptasensor was successfully applied to detect spiked Pb2+ in tap water samples, achieving recovery rates ranging from 96 to 108.4 %. By integrating nanomaterials, aptamers and enzymatic amplification, the aptasensor facilitates highly sensitive and selective detection of Pb2+, demonstrating potential for practical applications in environmental monitoring.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Exodesoxirribonucleasas , Grafito , Plomo , Nanocompuestos , Platino (Metal) , Plata , Grafito/química , Plomo/análisis , Plomo/química , Aptámeros de Nucleótidos/química , Exodesoxirribonucleasas/química , Técnicas Electroquímicas/métodos , Platino (Metal)/química , Nanocompuestos/química , Plata/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Límite de Detección , Contaminantes Químicos del Agua/análisis , Agua Potable/análisis , Electrodos , G-Cuádruplex
16.
Food Chem ; 453: 139651, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-38761736

RESUMEN

The food contamination with Ochratoxin A (OTA) has highlighted the need to create precise, sensitive, and convenient techniques. Herein, we proposed a label-free and immobilization-free ratiometric homogeneous electrochemical aptasensor based on dual catalytic hairpin self-assembly (CHA) for OTA detection. Methylene blue (MB) and ferrocene (Fc) in solution were utilized as label-free signaling molecules, generating a response signal (IMB) and a reference signal (IFc), respectively. The ratio of IMB/IFc was utilized as a measure to quantify OTA. Dual CHA was exploited to increase the ratiometric signal and enhance the amplification efficiency. This aptasensor achieved trace-level detection for OTA over a linear range of lower concentrations (1.0 × 10-3 ng/mL-1.0 × 103 ng/mL) with LOD of 92 fg/mL. The aptasensor was successfully applied to detect OTA in cereal and wine, with comparable results of HPLC-MS/MS. This strategy provided a viable platform for rapid, sensitive, and accurate detection of OTA in food.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Contaminación de Alimentos , Límite de Detección , Ocratoxinas , Vino , Ocratoxinas/análisis , Contaminación de Alimentos/análisis , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Vino/análisis , Grano Comestible/química , Catálisis
17.
Food Chem ; 452: 139536, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38723569

RESUMEN

Eating food contaminated by foodborne pathogens can lead to illness. The development of electrochemical sensors for pathogen detection has received widespread attention. However, the analytical performance of electrochemical sensors is inevitably affected by the non-specific adsorption of molecules in the sample. Moreover, the external signal probes might be affected by the complex components in the sample accompanied with signal suppression. This work presents an electrochemical aptasensor for Salmonella typhimurium detection based on the self-signal of poly-xanthurenic acid and the antifouling ability of chondroitin sulfate. The detection time was 60 min. The linear range was from 101 to 107 CFU/mL, and the detection limit was 3 CFU/mL. The biosensors presented good repeatability and storage stability. And the biosensors has been successfully applied in milk and orange juice. This strategy is expected to be applied in the design of other antifouling biosensors, to achieve rapid detection of pathogens and ensure food safety.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Contaminación de Alimentos , Leche , Salmonella typhimurium , Técnicas Biosensibles/instrumentación , Salmonella typhimurium/aislamiento & purificación , Técnicas Electroquímicas/instrumentación , Contaminación de Alimentos/análisis , Leche/microbiología , Leche/química , Animales , Límite de Detección , Microbiología de Alimentos , Jugos de Frutas y Vegetales/análisis , Jugos de Frutas y Vegetales/microbiología , Citrus sinensis/microbiología , Citrus sinensis/química
18.
Nanomaterials (Basel) ; 14(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38727369

RESUMEN

Silver ions (Ag+) are crucial in various fields, but pose environmental and health risks at high concentrations. This study presents a straightforward approach for the ultra-trace detection of Ag+, utilizing a composite of a cytosine-rich oligonucleotide (CRO) and an electrochemically reduced graphene oxide (ERGO). Initially, ERGO was synthesized on a glassy carbon electrode (GCE) through the reduction of graphene oxide (GO) via cyclic voltammetry. A methylene blue-tagged CRO (MB-CRO) was then anchored to the ERGO surface through π-π interactions, resulting in the formation of an MB-CRO-modified ERGO electrode (MB-CRO/ERGO-GCE). The interaction with Ag+ ions induced the formation of silver-mediated C-Ag+-C coordination, prompting the MB-CRO to adopt a hairpin structure. This conformational change led to the desorption of the MB-CRO from the ERGO-GCE, causing a variation in the redox current of the methylene blue associated with the MB-CRO. Electrochemical assays revealed that the sensor exhibits extraordinary sensitivity to Ag+ ions, with a linear detection range from 1 femtomolar (fM) to 100 nanomolars (nM) and a detection limit of 0.83 fM. Moreover, the sensor demonstrated high selectivity for Ag+ ions and several other benefits, including stability, reproducibility, and straightforward fabrication and operational procedures. Additionally, real sample analyses were performed using the modified electrode to detect Ag+ in tap and pond water samples, yielding satisfactory recovery rates.

19.
Bioelectrochemistry ; 158: 108709, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38621313

RESUMEN

Glypican-3 (GPC3) is an essential reference target for hepatocellular carcinoma detection, follow-up and prediction. Herein, a dual-signal electrochemical aptasensor based on reduced graphene oxide-cuprous oxide (RGO-Cu2O) nanozyme was developed for GPC3 detection. The RGO-Cu2O nanoenzyme displayed excellent electron transport effect, large specific surface area and outstanding peroxidase-like ability. The differential pulse voltammetry (DPV) signal of Cu2O oxidation fraction and the chronoamperometry (i-t) signal of H2O2 decomposition catalyzed by RGO-Cu2O nanozyme were used as dual-signal detection. Under optimal conditions, the log-linear response ranges were 0.1 to 500.0 ng/mL with the limit of detection 0.064 ng/mL for DPV technique, and 0.1-50.0 ng/mL for i-t technique (detection limit of 0.0177 ng/mL). The electrochemical aptasensor has remarkably analytical performance with wide response range, low detection limit, excellent repeatability and specificity, good recovery in human serum samples. The two output signals of one sample achieve self-calibration of the results, effectively avoiding the occurrence of possible leakage and misdiagnosis of a single detection signal, suggesting that it will be a promising method in the early biomarker detection.


Asunto(s)
Técnicas Biosensibles , Cobre , Técnicas Electroquímicas , Glipicanos , Grafito , Límite de Detección , Grafito/química , Glipicanos/sangre , Glipicanos/análisis , Humanos , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/métodos , Cobre/química , Aptámeros de Nucleótidos/química , Catálisis , Oxidación-Reducción , Peróxido de Hidrógeno/química
20.
ACS Appl Mater Interfaces ; 16(14): 17300-17312, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38557010

RESUMEN

Early secretory antigenic target-6 (ESAT-6) is regarded as the most immunogenic protein produced by Mycobacterium tuberculosis, whose detection is of great clinical significance for tuberculosis diagnosis. However, the detection of the ESAT-6 antigen has been hampered by the expensive cost and complex experimental procedures, resulting in low sensitivity. Herein, we developed a titanium carbide (Ti3C2Tx)-based aptasensor for ESAT-6 detection utilizing a triple-signal amplification strategy. First, acetylene black (AB) was immobilized on Ti3C2Tx through a cross-linking reaction to form the Ti3C2Tx-AB-PAn nanocomposite. Meanwhile, AB served as a conductive bridge, and Ti3C2Tx can synergistically promote the electron transfer of PAn. Ti3C2Tx-AB-PAn exhibited outstanding conductivity, high electrochemical signals, and abundant sites for the loading of ESAT-6 binding aptamer II (EBA II) to form a novel signal tag. Second, N-CNTs were adsorbed on NiMn layered double hydride (NiMn LDH) nanoflowers to obtain NiMn LDH/N-CNTs, exhibiting excellent conductivity and preeminent stability to be used as electrode modification materials. Third, the biotinylated EBA (EBA I) was immobilized onto a streptavidin-coated sensing interface, forming an amplification platform for further signal enhancement. More importantly, as a result of the synergistic effect of the triple-signal amplification platform, the aptasensor exhibited a wide detection linear range from 10 fg mL-1 to 100 ng mL-1 and a detection limit of 4.07 fg mL-1 for ESAT-6. We envision that our aptasensor provides a way for the detection of ESAT-6 to assist in the diagnosis of tuberculosis.


Asunto(s)
Compuestos de Anilina , Aptámeros de Nucleótidos , Técnicas Biosensibles , Mycobacterium tuberculosis , Tuberculosis , Humanos , Acetileno , Adsorción , Límite de Detección , Titanio , Tuberculosis/diagnóstico , Estreptavidina , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA