Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.618
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39253626

RESUMEN

Obscure gastrointestinal bleeding (OGIB), defined in 2010, involves bleeding from the GI tract that remains unexplained after standard diagnostic procedures. OGIB, which accounts for about 5% of all GI bleeds, poses diagnostic and management challenges, particularly due to the anatomical features of the small intestine. Advances in capsule endoscopy (CE) and balloon-assisted endoscopy have improved the diagnostic and therapeutic landscape for small intestinal lesions. Objective: To determine the recurrence rate and identify risk factors for recurrence following diagnostic and therapeutic interventions using CE and balloon-assisted endoscopy in patients with OGIB. Methods: A retrospective cohort study at Gifu University Hospital analyzed CE procedures for patients with OGIB from 2008 to 2022. Patients underwent CE with subsequent treatments based on the findings. Statistical analyses, including Kaplan-Meier and Cox proportional hazards models, were used to estimate cumulative recurrence rates and identify recurrence risk factors. Results: Out of 417 patients, 65.2% had positive CE findings, leading to therapeutic interventions in 16.3% of cases. The cumulative recurrence rates at 12, 24, and 36 months were 4.3%, 9.0%, and 13.9%, respectively. Liver cirrhosis (hazard rate: 4.15, 95% confidence interval 1.88-9.18, p < 0.01) was identified as a significant risk factor for recurrence. Conclusions: A significant recurrence rate in OGIB patients, with liver cirrhosis being a major risk factor. Despite diagnostic and therapeutic advances, a comprehensive approach including careful follow-up and consideration of risk factors is essential for management.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39286005

RESUMEN

A 55-year-old man with a history of distal gastrectomy was admitted to our hospital due to gastrointestinal bleeding from an anastomotic ulcer. After endoscopic hemostasis, his oral intake resumed after 1 day of fasting; however, he could not ingest food because of early satiety and nausea on the fifth day of oral intake resumption. Esophagogastroduodenoscopy was performed again to investigate the cause of anorexia and revealed a massive gastrolithiasis that was not observed in the previous esophagogastroduodenoscopy, which was diagnosed as the cause of his anorexia. Gastrolithiasis was treated with endoscopic removal the day after diagnosis, and the patient was discharged from the hospital after his symptoms resolved. Herein, we report the case of a patient with gastrolithiasis that developed and proliferated within 5 days.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38694540

RESUMEN

Patients with ulcerative colitis sometimes need a total colectomy with ileal pouch-anal anastomosis due to medically refractory disease or colitis-associated neoplasia. Up to 50% of patients with ulcerative colitis postoperatively develop pouchitis and the rate of chronic inflammatory pouch conditions requiring pouch excision or diverting ileostomy is reported to be 10%. In order to diagnose and monitor pouchitis, pouchoscopy is essential to assess endoscopic inflammatory findings of the J pouch and to survey neoplasia development, particularly in the remnant distal rectum. However, endoscopic protocols for the evaluation of the pouch may not be standardized worldwide and the reliability of existing disease activity indices for pouchitis has been questioned due to the lack of validation. Recently, reliable endoscopic scoring systems based on an observation of the anatomical location of the J pouch were reported and a significant association between the distribution pattern of endoscopic inflammation (i.e., endoscopic phenotype) and pouch outcomes was also uncovered. In this review, we discuss how to survey the J pouch using pouchoscopy, endoscopic indices for pouchitis disease activity, endoscopic phenotypes and classification, and the pathological mechanisms of pouchitis phenotype in patients with ulcerative colitis.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38881579

RESUMEN

Objectives: The effectiveness and safety of propofol-based sedation and midazolam sedation in pediatric bidirectional endoscopy were compared. Methods: We retrospectively analyzed the cases of pediatric patients (≤15 years old) who had undergone bidirectional endoscopy, esophagogastroduodenoscopy, and colonoscopy by pediatric gastroenterologists. Demographic data, indications, sedatives/dosages, clinical outcomes, endoscopic findings, adverse events, and total patient time requirements (total time in which patients stay in our hospital) were compared in the two sedation groups. Results: Ninety-one children (51 boys, 40 girls, mean age 13 years, range 9-15) treated at our hospital were enrolled. Propofol alone or in combination with midazolam and/or pentazocine was administered to 51 patients (propofol-based sedation group). Midazolam alone or in combination with pentazocine was administered to the other 40 patients (midazolam sedation group). In the propofol group, the following mean doses were used: propofol, 96 mg (range 40-145 mg); midazolam, 4.9 mg (range 3-5 mg); and pentazocine, 7.5 mg. In the midazolam group, the mean doses of midazolam and pentazocine were 6.2 mg (range 4-10 mg) and 15 mg, respectively. All procedures were successfully completed by pediatric gastroenterologists. The total procedure times and endoscopic findings were similar in the two groups, but the median patient time requirement in the propofol group was significantly shorter versus the midazolam group (7.3 h vs. 8.4 h, p < 0.001). No adverse events occurred in either group. Conclusions: Propofol-based sedation in pediatric bidirectional endoscopy was safely and effectively performed by pediatric gastroenterologists, and its patient time requirement was shorter than that for midazolam sedation.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39011510

RESUMEN

Objectives: Blister pack (BP) ingestion poses serious risks, such as gastrointestinal perforation, and accurate localization by computed tomography (CT) is a common practice. However, while it has been reported in vitro that CT visibility varies with the material type of BPs, there have been no reports on this variability in clinical settings. In this study, we investigated the CT detection rates of different BPs in clinical settings. Methods: This single-center retrospective study from 2010 to 2022 included patients who underwent endoscopic foreign body removal for BP ingestion. The patients were categorized into two groups for BP components, the polypropylene (PP) and the polyvinyl chloride (PVC)/polyvinylidene chloride (PVDC) groups. The primary outcome was the comparison of CT detection rates between the groups. We also evaluated whether the BPs contained tablets and analyzed their locations. Results: This study included 61 patients (15 in the PP group and 46 in the PVC/PVDC group). Detection rates were 97.8% for the PVC/PVDC group compared to 53.3% for the PP group, a significant difference (p < 0.01). No cases of BPs composed solely of PP were detected by CT. Blister packs were most commonly found in the upper thoracic esophagus. Conclusions: Even in a clinical setting, the detection rates of PVC and PVDC were higher than that of PP alone. Identifying PP without tablets has proven challenging in clinical. Considering the risk of perforation, these findings suggest that esophagogastroduodenoscopy may be necessary, even if CT detection is negative.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38975290

RESUMEN

The general principles of gastrointestinal endoscopy training in the United States were formulated and summarized more than a decade ago and the principles have been consistent until now. To summarize, trainees should be prepared to (i) appropriately recommend endoscopic procedures as indicated by the findings of the consultative evaluation, with an explicit understanding of accepted specific indications, contraindications, and diagnostic/therapeutic alternatives, (ii) perform procedures safely, completely, and expeditiously, including possessing a thorough understanding of the principles of conscious sedation/analgesia techniques, the use of anesthesia-assisted sedation where appropriate, and pre-procedure clinical assessment and patient monitoring, (iii) correctly interpret endoscopic findings and integrate them into medical or endoscopic therapy, (iv) identify risk factors for each procedure, understand how to minimize each, and recognize and appropriately manage complications when they occur, (v) acknowledge the limitations of endoscopic procedures and personal skills and know when to request help, and (vi) understand the principles of quality measurement and improvement. This article provides an overview of the endoscopy training system and structure, evaluation scheme, and competence and credentialing process in the United States.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38817687

RESUMEN

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38903962

RESUMEN

Objectives: For early gastrointestinal lesions, size is an important factor in the selection of treatment. Virtual scale endoscope (VSE) is a newly developed endoscope that can measure size more accurately than visual measurement. This study aimed to investigate whether VSE measurement is accurate for early gastrointestinal lesions of various sizes and morphologies. Methods: This study prospectively enrolled patients with early gastrointestinal lesions ≤20 mm in size visually. Lesion sizes were measured in the gastrointestinal tract visually, on endoscopic resection specimens with VSE, and finally on endoscopic resection specimens using a ruler. The primary endpoint was the normalized difference (ND) of VSE measurement. The secondary endpoints were the ND of visual measurement and the variation between NDs of VSE and visual measurements. ND was calculated as (100 × [measured size - true size] / true size) (%). True size was defined as size measured using a ruler. Results: This study included 60 lesions from April 2022 to December 2022, with 20 each in the esophagus, stomach, and colon. The lesion size was 14.0 ± 6.3 mm (mean ± standard deviation). Morphologies were protruded, slightly elevated, and flat or slightly depressed type in 8, 24, and 28 lesions, respectively. The primary endpoint was 0.3 ± 8.8%. In the secondary endpoints, the ND of visual measurement was -1.7 ± 29.3%, and the variability was significantly smaller in the ND of VSE measurement than in that of visual measurement (p < 0.001, F-test). Conclusions: VSE measurement is accurate for early gastrointestinal lesions of various sizes and morphologies.

9.
Artículo en Inglés | MEDLINE | ID: mdl-39144408

RESUMEN

Objectives: We aimed to conduct a systematic review and meta-analysis to assess the value of image-enhanced endoscopy including blue laser imaging (BLI), linked color imaging, narrow-band imaging (NBI), and texture and color enhancement imaging to detect and diagnose gastric cancer (GC) compared to that of white-light imaging (WLI). Methods: Studies meeting the inclusion criteria were identified through PubMed, Cochrane Library, and Japan Medical Abstracts Society databases searches. The pooled risk ratio for dichotomous variables was calculated using the random-effects model to assess the GC detection between WLI and image-enhanced endoscopy. A random-effects model was used to calculate the overall diagnostic performance of WLI and magnifying image-enhanced endoscopy for GC. Results: Sixteen studies met the inclusion criteria. The detection rate of GC was significantly improved in linked color imaging compared with that in WLI (risk ratio, 2.20; 95% confidence interval [CI], 1.39-3.25; p < 0.01) with mild heterogeneity. Magnifying endoscopy with NBI (ME-NBI) obtained a pooled sensitivity, specificity, and area under the summary receiver operating curve of 0.84 (95 % CI, 0.80-0.88), 0.96 (95 % CI, 0.94-0.97), and 0.92, respectively. Similarly, ME-BLI showed a pooled sensitivity, specificity, and area under the curve of 0.81 (95 % CI, 0.77-0.85), 0.85 (95 % CI, 0.82-0.88), and 0.95, respectively. The diagnostic efficacy of ME-NBI/BLI for GC was evidently high compared to that of WLI, However, significant heterogeneity among the NBI studies still existed. Conclusions: Our meta-analysis showed a high detection rate for linked color imaging and a high diagnostic performance of ME-NBI/BLI for GC compared to that with WLI.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38746904

RESUMEN

Image-enhanced endoscopy (IEE) has advanced gastrointestinal disease diagnosis and treatment. Traditional white-light imaging has limitations in detecting all gastrointestinal diseases, prompting the development of IEE. In this review, we explore the utility of IEE, including texture and color enhancement imaging and red dichromatic imaging, in pancreatobiliary (PB) diseases. IEE includes methods such as chromoendoscopy, optical-digital, and digital methods. Chromoendoscopy, using dyes such as indigo carmine, aids in delineating lesions and structures, including pancreato-/cholangio-jejunal anastomoses. Optical-digital methods such as narrow-band imaging enhance mucosal details and vessel patterns, aiding in ampullary tumor evaluation and peroral cholangioscopy. Moreover, red dichromatic imaging with its specific color allocation, improves the visibility of thick blood vessels in deeper tissues and enhances bleeding points with different colors and see-through effects, proving beneficial in managing bleeding complications post-endoscopic sphincterotomy. Color enhancement imaging, a novel digital method, enhances tissue texture, brightness, and color, improving visualization of PB structures, such as PB orifices, anastomotic sites, ampullary tumors, and intraductal PB lesions. Advancements in IEE hold substantial potential in improving the accuracy of PB disease diagnosis and treatment. These innovative techniques offer advantages paving the way for enhanced clinical management of PB diseases. Further research is warranted to establish their standard clinical utility and explore new frontiers in PB disease management.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38715896

RESUMEN

Immunoglobulin G4 (IgG4)-related diseaseis a systemic inflammatory condition of unknown etiology characterized by increases in serum IgG4 and in the number of IgG4-positive cells in affected tissues. One of the commonly involved locations is the pancreas; this condition is known as type 1 autoimmune pancreatitis (AIP). Type 1 AIP, which shows a biliary stricture in the intrapancreatic bile duct, can be misdiagnosed as a malignancy due to similar cholangiography findings and clinical presentation. In rare cases complicated by post-bulbar duodenal ulcers, differentiating between type 1 AIP and malignancies is even more difficult. An 81-year-old male was referred to our hospital for the treatment of a pancreatic head mass and obstructive jaundice. Serological and radiological findings were consistent with both type 1 AIP and a malignancy. Gastroduodenoscopy revealed a post-bulbar duodenal ulcer with endoscopic features that evoked malignant duodenal invasion. Although biopsies were negative for malignant cells, subsequent bleeding from the lesion suggested the progression of malignancy, which led to surgical resection. Pancreatoduodenectomy and pathological examination indicated that type 1 AIP was present. Simultaneously, the involvement of IgG4-related disease in the ulcerative lesion was suggested. To our knowledge, this is the first reported case of type 1 AIP complicated by post-bulbar duodenal ulcers, which was misdiagnosed as malignancy and considered an IgG4-related gastrointestinal disease associated with type 1 AIP.

12.
Artículo en Inglés | MEDLINE | ID: mdl-38845631

RESUMEN

Objectives: We aimed to evaluate the usefulness and acceptability of CapsoCam Plus (CapsoCam) in Japanese patients. Methods: This retrospective single-center study enrolled 930 patients with suspected small-bowel bleeding (SSBB) who underwent capsule endoscopy. Thirty-three patients using CapsoCam and PillCam SB3 (SB3) were matched using propensity score matching. The diagnostic yield and the acceptability of CapsoCam were evaluated. Results: There was no SSBB case where capsule endoscopy was performed within 48 h of bleeding. CapsoCam had a significantly higher observation rate of the entire small bowel (97% vs. 73%, p = 0.006) and Vater's papilla (82% vs. 15%, p < 0.001) than SB3. The reading time of CapsoCam was significantly longer than that of SB3 (30 vs. 25 min, p < 0.001), and CapsoCam's time from the capsule endoscopy swallowing to read completion was longer than that of SB3 (37 vs. 12 h, p < 0.001). The two groups showed no difference in the capsule endoscopy findings according to the P classification. Notably, 85% of the patients using CapsoCam reported examination distress as "not at all" or "almost not," and 94% reported swallowing difficulty as "very easy" or "easy." Conclusions: CapsoCam took time to read; however, it is a well-tolerated examination with a high observation rate of Vater's papilla and entire small-bowel mucosa. Detectability of bleeding sources was comparable in both modalities for cases of occult SSBB and overt SSBB more than 48 h after bleeding. CapsoCam is a useful modality for patients with SSBB.

13.
Artículo en Inglés | MEDLINE | ID: mdl-38895560

RESUMEN

Objectives: Black spots (BSs) are lentiginous findings observed in the gastric body and fundus during upper gastrointestinal endoscopy and are predominantly seen in patients undergoing Helicobacter pylori eradication treatment. However, the detailed patient background and exact composition are poorly understood. This study aims to clarify the clinicopathological features of BSs, examine patient demographics, and use the NanoSuit-correlative light and electron microscopy (CLEM) method combined with scanning electron microscopy-energy dispersive X-ray spectroscopy for elemental analysis. Methods: Patients who underwent upper gastrointestinal endoscopy between 2017 and 2022 were included. Data on age, medications, blood tests, and H. pylori infection status were retrospectively gathered from medical records. Univariate analysis was conducted to examine BS presence, with results then used in a multivariate model to identify associated risk factors. Additionally, pathological specimens from patients with BSs were analyzed for elemental composition using the NanoSuit-CLEM method combined with scanning electronmicroscopy-energy dispersive X-ray spectroscopy. Results: An analysis of 6778 cases identified risk factors for BSs, including older age and using proton pump inhibitors, statins, corticosteroids, and antithrombotic drugs. Endoscopically, BSs correlated with higher gastric atrophy and lower active H. pylori infection. Iron deposition at BS sites was specifically identified using NanoSuit-CLEM. Conclusions: BSs on gastrointestinal endoscopy may indicate an absence of active H. pylori inflammation. The discovery of iron deposition within BSs using the NanoSuit-CLEM method has offered new insights into the possible causative factors and advances our understanding of the etiology of BSs, bringing us closer to unraveling the underlying mechanisms of their formation.

14.
Artículo en Inglés | MEDLINE | ID: mdl-38919514

RESUMEN

Gastric mucosal changes associated with long-term potassium-competitive acid blocker and proton pump inhibitor (PPI) therapy may raise concern. In contrast to that for PPIs, the evidence concerning the safety of long-term potassium-competitive acid blocker use is scant. Vonoprazan (VPZ) is a representative potassium-competitive acid blocker released in Japan in 2015. In order to shed some comparative light regarding the outcomes of gastric mucosal lesions associated with a long-term acid blockade, we have reviewed six representative gastric mucosal lesions: fundic gland polyps, gastric hyperplastic polyps, multiple white and flat elevated lesions, cobblestone-like gastric mucosal changes, gastric black spots, and stardust gastric mucosal changes. For these mucosal lesions, we have evaluated the association with the type of acid blockade, patient gender, Helicobacter pylori infection status, the degree of gastric atrophy, and serum gastrin levels. There is no concrete evidence to support a significant relationship between VPZ/PPI use and the development of neuroendocrine tumors. Current data also shows that the risk of gastric mucosal changes is similar for long-term VPZ and PPI use. Serum hypergastrinemia is not correlated with the development of some gastric mucosal lesions. Therefore, serum gastrin level is unhelpful for risk estimation and for decision-making relating to the cessation of these drugs in routine clinical practice. Given the confounding potential neoplastic risk relating to H. pylori infection, this should be eradicated before VPZ/PPI therapy is commenced. The evidence to date does not support the cessation of clinically appropriate VPZ/PPI therapy solely because of the presence of these associated gastric mucosal lesions.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38915785

RESUMEN

Endoscopic submucosal dissection (ESD) is a transformative advancement in the endoscopic management of superficial gastrointestinal lesions. Initially conceived for the treatment of early gastric cancer, ESD has demonstrated proficiency in achieving en-bloc resection of superficial gastrointestinal lesions. ESD has experienced widespread acceptance in Japan and East Asia; however, its adoption in the USA remains delayed. This initial hesitancy could be attributed to procedural complexity and training demands; nonetheless, recently, ESD has been gaining popularity in the USA. This is due to the advancements in endoscopic technology, tailored training programs, and cumulative evidence regarding the efficacy and safety of ESDs. This review aimed to deliberate the historical progress, current implementation, and prospective trajectory of ESDs in the USA. With ongoing clinical research, technological integration, and educational efforts, ESD is likely to become the gold standard for managing large gastrointesitinal lesions. This progress marks an imperative step toward less invasive, more precise, and patient-centric approaches regarding advanced therapeutic endoscopy in the USA.

16.
Artículo en Inglés | MEDLINE | ID: mdl-39211761

RESUMEN

Gastric endoscopic mucosal resection is challenging due to the slippery mucosa, abundant blood vessels, and the presence of mucus. We developed gel immersion endoscopy to secure the visual field, even in a blood-filled gastrointestinal lumen in 2016. Clear gel with appropriate viscosity, instead of water, can prevent rapid mixture with blood and facilitate identification of the culprit vessel. We further optimized the gel for endoscopic treatment, and the resultant product, Viscoclear (Otsuka Pharmaceutical Factory) was first released in Japan in 2020. The viscosity of this gel has been optimized to maximize endoscopic visibility without compromising the ease of its irrigation. The aim of this study is to clarify the effectiveness of gel immersion endoscopic mucosal resection for small-sized early gastric neoplasms. Seven lesions in seven patients were treated by gel immersion endoscopic mucosal resection. The size of all lesions was under 10 mm. The median procedure time was 4.5 min. Intraoperative bleeding occurred in four of seven lesions immediately after snare resection and was easily controlled by endoscopic hemostatic forceps during the gel immersion endoscopy. The R0 resection rate was 100%. In conclusion, gel immersion endoscopic mucosal resection may be a straightforward, rapid, and safe technique for resecting superficial gastric neoplasms <10 mm in diameter.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39323618

RESUMEN

Objective: This study aimed to implement green endoscopy through the microbiological assessment of gowning techniques during endoscopy to reduce carbon emissions and separate medical waste. Methods: Twenty-five patients who performed esophagogastroduodenoscopy from March to May 2024 were included in this study. Four sections of the isolation gowns (anterior, posterior, right, and left) were cut into 2 cm2 after endoscopy, and the rate of microbial contamination was examined using the stamp method. Results: The endoscopic examination time was 8 min (6-12), and endoscopy was performed by 10 expert endoscopists, six endoscopists, and nine residents. The overall isolation gown contamination rate was 56%, with 25%, 20.8%, 20.8%, and 33.3% in the front, back, as well as right and left arms, respectively. The rates of isolation gown contamination rates in the expert endoscopists, endoscopists, and residents groups were 30%, 50%, and 77.8%, respectively, with a higher rate in the residents group. Regardless of the physician's performance, bacterial detection was consistently higher in the left arm (42.9% vs. 40% vs. 25%; p = 0.093). The detected bacteria comprised 58% Gram-positive and 42% Gram-negative organisms, including those from tap water used for endoscopy bacteria and obtained from the participant's skin or mouth. No pathogenic organisms were detected. Conclusions: The bacteria detected in disposable gowns after gastrointestinal endoscopy were non-pathogenic. Thus, our findings suggest that changing all personal protective equipment of respective endoscopes might not be essential. We advocate for green endoscopy to achieve sustainable development goals and reduce medical waste.

18.
Artículo en Inglés | MEDLINE | ID: mdl-39346019

RESUMEN

Gastrointestinal tract involvement in Langerhans cell histiocytosis (LCH) is extremely rare, with limited documentation of endoscopic manifestations. We report a 19-month-old girl who presented with repeated diarrhea and bloody stools, accompanied by recurrent pulmonary infections, anemia, hypoproteinemia, thrombocytopenia, coagulopathy, and hepatosplenomegaly with lymphadenopathy. Initial treatment with antibacterial agents, mesalazine, thalidomide, and prednisone led to temporary improvement; however, the symptoms repeatedly relapsed. She underwent three digestive endoscopies, but until the third endoscopy, a definitive diagnosis of Langerhans cell histiocytosis was established through biopsy. While upper gastrointestinal tract findings were not significant, notable changes were observed in the colorectal region. A colonoscopy revealed progression from erythema to diffuse hyperemia and edema, with erythema, erosion, and superficial ulcers extending into the distal ileal mucosa. Genetic analysis identified a BRAF-V600E mutation. Following treatment with chemotherapy (vincristine and prednisone) and the BRAF inhibitor dabrafenib, the patient demonstrated significant clinical improvement within days. At the 1-year follow-up, the patient had normal bowel movements and a weight gain of 2.5 kg. Early gastrointestinal endoscopy with multiple biopsies in suspected children can facilitate early detection. Dabrafenib is a viable treatment option for Langerhans cell histiocytosis.

19.
Dig Dis Sci ; 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39354271

RESUMEN

BACKGROUND: TC-325 powder has been successfully used in the management of malignancy-related upper gastrointestinal bleeding (UGIB) with favorable results. We conducted a meta-analysis of randomized controlled trials (RCTs) comparing TC-325 hemostatic powder with standard endoscopic treatments in the management of malignancy-related UGIB. METHODS: Several databases were reviewed from inception to May 02, 2024 to identify RCTs comparing TC-325 and standard endoscopic treatments for the management of malignancy-related UGIB. Our outcomes of interest were immediate hemostasis, 30-day rebleeding, length of hospital stay, need for surgery, need for angiographic embolization, and all-cause mortality. We calculated pooled risk ratio (RR) with 95% confidence intervals (CI) for categorical variables and mean difference (MD) with 95% CI for continuous variables. We used a random effect model to analyze the data and heterogeneity was assessed by I2 statistic. RESULTS: Four RCTs with 227 patients were included. We found that, the rate of immediate hemostasis was significantly higher in the TC-325 group compared to the standard therapy group, RR (95% CI): 1.48 (1.26, 1.74). There was no significant difference in 30-day rebleeding between the groups RR (95% CI): 0.52 (0.15, 1.76). We found no significant difference in other outcomes between groups such as the need for angiographic embolization, all-cause mortality, length of hospital stay, and need for surgery. CONCLUSIONS: We found that, TC-325 hemostatic powder was superior to standard endoscopic treatments in achieving immediate hemostasis in patients with malignancy-related UGIB.

20.
Clin Endosc ; 57(5): 656-665, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39354833

RESUMEN

BACKGROUND/AIMS: Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation. METHODS: We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records. RESULTS: Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42-61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods. CONCLUSIONS: The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA