Resultados 1 - 20 de 2.918
Filtrar
1.
Phys Eng Sci Med ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954379

RESUMEN

Contrast-enhanced mammography is being increasingly implemented clinically, providing much improved contrast between tumour and background structures, particularly in dense breasts. Although CEM is similar to conventional mammography it differs via an additional exposure with high energy X-rays (≥ 40 kVp) and subsequent image subtraction. Because of its special operational aspects, the CEM aspect of a CEM unit needs to be uniquely characterised and evaluated. This study aims to verify the utility of a commercially available phantom set (BR3D model 020 and CESM model 022 phantoms (CIRS, Norfolk, Virginia, USA)) in performing key CEM performance tests (linearity of system response with iodine concentration and background subtraction) on two models of CEM units in a clinical setting. The tests were successfully performed, yielding results similar to previously published studies. Further, similarities and differences in the two systems from different vendors were highlighted, knowledge of which may potentially facilitate optimisation of the systems.

2.
Radiography (Lond) ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38955646

RESUMEN

INTRODUCTION: Radiotherapy is the standard treatment for breast cancer patients after surgery. However, radiotherapy can cause side effects such as dry and moist desquamation of the patient's skin. The dose calculation from a treatment planning system (TPS) might also be inaccurate. The purpose of this study is to measure the surface dose on the CIRS thorax phantom by an optically stimulated luminescent dosimeter (OSLD). METHODS: The characteristics of OSLD were studied in terms of dose linearity, reproducibility, and angulation dependence on the solid water phantom. To determine the surface dose, OSLD (Landauer lnc., USA) was placed on 5 positions at the CIRS phantom (Tissue Simulation and Phantom Technology, USA). The five positions were at the tip, medial, lateral, tip-medial, and tip-lateral. Then, the doses from OSLD and TPS were compared. RESULTS: The dosimeter's characteristic test was good. The maximum dose at a depth of 15 mm was 514.46 cGy, which was at 100%. The minimum dose at the surface was 174.91 cGy, which was at 34%. The results revealed that the surface dose from TPS was less than the measurement. The percent dose difference was -2.17 ± 6.34, -12.08 ± 3.85, and -48.71 ± 1.29 at the tip, medial, and lateral positions, respectively. The surface dose from TPS at tip-medial and tip-lateral was higher than the measurement, which was 12.56 ± 5.55 and 10.45 ± 1.76 percent dose different, respectively. CONCLUSION: The percent dose difference is within the acceptable limit, except for the lateral position because of the body curvature. However, OSLD is convenient to assess the radiation dose, and further study is to measure in vivo. IMPLICATION FOR PRACTICE: The OSL NanoDot dosimeter can be used for dose validation with a constant setup location. The measurement dose is higher than the dose from TPS, except for some tilt angles.

4.
EJNMMI Phys ; 11(1): 54, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951352

RESUMEN

BACKGROUND: Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI. MATERIALS AND METHODS: We implemented a standard measurement protocol, which applies a flow phantom in order to compare image-derived flow values with respect to a ground truth flow value with [15O]H2O MPI performed on both a Discovery MI (DMI-20, GE Healthcare) and a Biograph Vision 600 (Vision-600, Siemens Healthineers) system. Both systems have automatic [15O]H2O radio water generators (Hidex Oy) individually installed, allowing us to also study the differences occurring due to two different bolus delivery systems. To investigate the technical factors contributing to the modelled flow values, we extracted the [15O]H2O bolus profiles, the flow values from the kinetic modeling (Qin and Qout), and finally calculated their differences between test-retest measurements on both systems. RESULTS: The measurements performed on the DMI-20 system produced Qin and Qout values corresponging to each other as well as to the reference flow value across all test-retest measurements. The repeatability differences on DMI-20 were 2.1% ± 2.6% and 3.3% ± 4.1% for Qin and Qout, respectively. On Vision-600 they were 10% ± 8.4% and 11% ± 10% for Qin and Qout, respectively. The measurements performed on the Vision-600 system showed more variation between Qin and Qout values across test-retest measurements and exceeded 15% difference in 7/24 of the measurements. CONCLUSIONS: A preliminary protocol for measuring the accuracy and reproducibility of flow values in [15O]H2O MPI between digital PET/CT systems was assessed. The test-retest reproducibility falls below 15% in majority of the measurements conducted between two individual injector systems and two digital PET/CT systems. This study highlights the importance of implementing a standardized bolus injection and delivery protocol and importance of assessing technical factors affecting flow value reproducibility, which should be carefully investigated in a multi-center setting.

5.
Pain Med ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38964349

RESUMEN

OBJECTIVE: To explore the relationship between sociodemographic, clinical, and neurophysiological variables and health-related quality of life (HR-QOL) of patients with phantom limb pain. METHODS: This is a cross-sectional analysis of a previous clinical trial. Univariate and multivariate linear and logistic regression analyses were used to model the predictors of HR-QOL. We utilized a sequential modeling approach with increasing adjustment levels, controlling for age and sex, and other relevant clinical variables (time since amputation, level of amputation, and pain). HR-QOL was assessed by the SF-36 Health Survey and its eight subdomains. RESULTS: We analyzed baseline data from 92 patients with lower-limb amputations. They were mostly male (63%), 45.2 ± 15.6 years, with a mean time since amputation of 82.7 ± 122.4 months, and an overall SF-36 score of 55.9 ± 21.5. We found an association between intracortical facilitation in the affected hemisphere (ICF), gabapentin usage, and HR-QOL. ICF is a predictor of better HRQOL, whereas gabapentin usage was associated with a poorer HR-QOL, with the main model explaining 13.4% of the variance in the outcome. For the SF-36 subdomains, ICF was also a positive predictor for social functioning, bodily pain, and vitality, while medication usage was associated with lower scores in mental health, general health perception, bodily pain, and vitality. CONCLUSION: We found firsthand two new independent predictors of HR-QOL in individuals with PLP, namely, the neurophysiological metric ICF and gabapentin usage. These results highlight the role of the motor cortex excitability in the HR-QOL and stress the need for treatments that favor the neuroplastic adaptation after amputation, for which ICF may be used as a possible marker.

6.
Eur J Radiol ; 177: 111599, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38970995

RESUMEN

PURPOSE: This study aims to develop Various Age-size Pediatric Chest Phantoms (VAPC) to evaluate low-dose protocol that approximates clinical conditions achieved by low organ-specific doses and optimal image quality among the challenges of pediatric size variations. METHODS: Three original pediatric data aged 1, 4, and 7 years were used as a reference for developing VAPC phantoms. Six protocols, namely standard dose (STD) and low dose (low mA and low kV) reconstructed using Filtered Back Projection (FBP) and iterative reconstruction (IR) algorithms, were investigated. This study directly measured the lungs, heart, and spinal cord dose using LD-V1 film. Linearity, Modulation Transfer Function (MTF), Contrast to Noise Ratio (CNR), and Noise Power Spectrum (NPS) were evaluated to assess the CT image quality of the VAPC phantom. RESULTS: This study found that the mean organ-specific dose was higher than CTDIvol. A Comparison of mean lung doses showed VAPC phantom 1 (y.o.) received 74.8% and 137.2% more doses than 4 (y.o.) and 7 (y.o.), respectively. Low kV produces a lower organ dose than low mA. The linearity of CT numbers is not biased at low doses. Differences in age measures significantly influenced organ-specific dose, MTF, CNR, and NPS. CONCLUSION: Smaller pediatrics are still exposed to higher doses at low-dose examinations, whereas larger pediatrics have lower contrast resolution and increased image noise. CT number linearity is unbiased. The combination of low kV with FBP produces higher spatial resolution, while low mA with IR effectively reduces noise to detect low-contrast objects better.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38959869

RESUMEN

OBJECTIVE: The availability of tissue-mimicking materials (TMMs) for manufacturing high-quality phantoms is crucial for standardization, evaluating novel quantitative approaches, and clinically translating new imaging modalities, such as photoacoustic imaging (PAI). Recently, a gel comprising the copolymer styrene-ethylene/butylene-styrene (SEBS) in mineral oil has shown significant potential as TMM due to its optical and acoustic properties akin to soft tissue. We propose using artists' oil-based inks dissolved and diluted in balsam turpentine to tune the optical properties. APPROACH: A TMM was fabricated by mixing a SEBS copolymer and mineral oil, supplemented with additives to tune its optical absorption and scattering properties independently. A systematic investigation of the tuning accuracies and relationships between concentrations of oil-based pigments and optical absorption properties of the TMM across visible and near-infrared wavelengths using collimated transmission spectroscopy was conducted. The photoacoustic spectrum of various oil-based inks was studied to analyze the effect of increasing concentration and depth. MAIN RESULTS: Artists' Oil-based inks dissolved in turpentine proved effective as additives to tune the optical absorption properties of mineral oil SEBS-gel with high accuracy. The TMMs demonstrated long-term stability and suitability for producing phantoms with desired optical absorption properties for PAI studies. SIGNIFICANCE: The findings, including tuning of optical absorption and spectral shape, suggest that this TMM facilitates the development of more sophisticated phantoms of arbitrary shapes. This approach holds promise for advancing the development of PAI, including investigation of the spectral coloring effect. In addition, it can potentially aid in the development and clinical translation of ultrasound optical tomography.

8.
J Radiol Prot ; 44(3)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38950524

RESUMEN

The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%-20% with a slight impact on image quality (CNR decreases by 2%-10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85-90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.


Asunto(s)
Pelvis , Fantasmas de Imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica , Pelvis/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
J Biophotonics ; : e202400007, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38894568

RESUMEN

Measurement of anisotropy factor (g) in the presence of nanoparticles (NPs) is important for understanding light distribution for plasmonic photothermal cancer therapeutics. Here, anisotropy factor is investigated through bilayer phantoms (epidermal and dermal) of various thicknesses incorporated with gold nanorods (GNRs) concentrations of 10-40 µg/mL by using in-house developed goniometric setup. Results show that 10 µg/mL GNRs in the phantom increase g by ~50% (g = 0.9471) w.r.t. phantom without NPs. Higher concentrations (40 µg/mL) of GNRs decrease g by ~43% (g = 0.5341) w.r.t. phantom with 10 µg/mL GNRs. For 40 µg/mL GNRs phantom, the anisotropy factor reduces by 47% for phantom thickness from 600 to 1800 µm. Anisotropy factor of GNR embedded phantom increased by 44% by using glycerol (10%-40%). Incorporation of NPs in a tumor significantly affects g, a major parameter for light distribution. These measurements provide insights for light scattering based on nanoparticle doses for plasmonic photothermal therapeutics.

10.
J Biophotonics ; : e202400032, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38894573

RESUMEN

Elastography is a noninvasive technique for characterizing the mechanical properties of biological tissues. Conventional methods have limitations in resolution and sensitivity, hindering disease detection in clinical diagnostics. To address these issues, this study developed an optical-resolution photoacoustic microelastography (OR-PAME) system. Using an agar tissue phantom with varying agar concentrations and contrast agents, PAME evaluated elasticity distribution under compression in both lateral and axial dimensions. It indirectly measured elastic properties by correlating photoacoustic responses, temporal lags, and induced displacement. We also applied the system to the study of the distribution of elastic characteristics of the liver tissue after ablation, which confirmed the potential of OR-PAME in the study of elastic characteristics. Quantitative analysis showed greater lateral displacement in regions with reduced agar concentrations, indicating decreased stiffness. PAME also detected vertical displacement along the axial plane, validating its efficacy in elastographic imaging. By improving resolution and penetration, PAME provides superior visualization of elasticity distribution. Its methodology correlates microstructural alterations with tissue biomechanics, holding potential implications in medical diagnostics.

11.
J Med Ultrasound ; 32(2): 121-133, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38882616

RESUMEN

Background: Tissue-mimicking phantoms (TMPs) have been used extensively in clinical and nonclinical settings to simulate the thermal effects of focus ultrasound (FUS) technology in real tissue or organs. With recent technological developments in the FUS technology and its monitoring/guided techniques such as ultrasound-guided FUS and magnetic resonance-guided FUS (MRgFUS) the need for TMPs are more important than ever to ensure the safety of the patients before being treated with FUS for a variety of diseases (e.g., cancer or neurological). The purpose of this study was to prepare a tumor-mimicking phantom (TUMP) model that can simulate competently a tumor that is surrounded by healthy tissue. Methods: The TUMP models were prepared using polyacrylamide (PAA) and agar solutions enriched with MR contrast agents (silicon dioxide and glycerol), and the thermosensitive component bovine serum albumin (BSA) that can alter its physical properties once thermal change is detected, therefore offering real-time visualization of the applied FUS ablation in the TUMPs models. To establish if these TUMPs are good candidates to be used in thermoablation, their thermal properties were characterized with a custom-made FUS system in the laboratory and a magnetic resonance imaging (MRI) setup with MR-thermometry. The BSA protein's coagulation temperature was adjusted at 55°C by setting the pH of the PAA solution to 4.5, therefore simulating the necrosis temperature of the tissue. Results: The experiments carried out showed that the TUMP models prepared by PAA can change color from transparent to cream-white due to the BSA protein coagulation caused by the thermal stress applied. The TUMP models offered a good MRI contrast between the TMPs and the TUMPs including real-time visualization of the ablation area due to the BSA protein coagulation. Furthermore, the T2-weighted MR images obtained showed a significant change in T2 when the BSA protein is thermally coagulated. MR thermometry maps demonstrated that the suggested TUMP models may successfully imitate a tumor that is present in soft tissue. Conclusion: The TUMP models developed in this study have numerous uses in the testing and calibration of FUS equipment including the simulation and validation of thermal therapy treatment plans with FUS or MRgFUS in oncology applications.

12.
J Biophotonics ; : e202400028, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38877699

RESUMEN

Skin burns that include tissue coagulation necrosis imply variations in stiffness. Dynamic phase-sensitive optical coherence elastography (OCE) is used to evaluate the stiffness of burned skin nondestructively in this paper. The homemade dynamic OCE was initially verified through tissue-mimicking phantom experiments regarding Rayleigh wave speed. After being burned with a series of temperatures and durations, the corresponding structure and stiffness variations of mice skin were demonstrated by histological images, optical coherence tomography B-scans, and OCE elastic wave speed maps. The results clearly displayed the variation in elastic properties and stiffness of the scab edge extending in the lateral direction. Statistical analysis revealed that murine skin burned at temperatures exceeding 100°C typically exhibited greater stiffness than skin burned at temperatures below 100°C. The dynamic OCE technique shows potential application for incorporating elasticity properties as a biomechanical extension module to diagnose skin burn injuries.

13.
Diagnostics (Basel) ; 14(11)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38893664

RESUMEN

(1) Background: Open-source software tools are available to estimate proton density fat fraction (PDFF). (2) Methods: We compared four algorithms: complex-based with graph cut (GC), magnitude-based (MAG), magnitude-only estimation with Rician noise modeling (MAG-R), and multi-scale quadratic pseudo-Boolean optimization with graph cut (QPBO). The accuracy and reliability of the methods were evaluated in phantoms with known fat/water ratios and a patient cohort with various grades (S0-S3) of steatosis. Image acquisitions were performed at 1.5 Tesla (T). (3) Results: The PDFF estimates showed a nearly perfect correlation (Pearson r = 0.999, p < 0.001) and inter-rater agreement (ICC = from 0.995 to 0.999, p < 0.001) with true fat fractions. The absolute bias was low with all methods (0.001-1%), and an ANCOVA detected no significant difference between the algorithms in vitro. The agreement across the methods was very good in the patient cohort (ICC = 0.891, p < 0.001). However, MAG estimates (-2.30% ± 6.11%, p = 0.005) were lower than MAG-R. The field inhomogeneity artifacts were most frequent in MAG-R (70%) and GC (39%) and absent in QPBO images. (4) Conclusions: The tested algorithms all accurately estimate PDFF in vitro. Meanwhile, QPBO is the least affected by field inhomogeneity artifacts in vivo.

14.
Sensors (Basel) ; 24(11)2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38894294

RESUMEN

Magnetoencephalography (MEG) non-invasively provides important information about human brain electrophysiology. The growing use of optically pumped magnetometers (OPM) for MEG, as opposed to fixed arrays of cryogenic sensors, has opened the door for innovation in system design and use cases. For example, cryogenic MEG systems are housed in large, shielded rooms to provide sufficient space for the system dewar. Here, we investigate the performance of OPM recordings inside of a cylindrical shield with a 1 × 2 m2 footprint. The efficacy of shielding was measured in terms of field attenuation and isotropy, and the value of post hoc noise reduction algorithms was also investigated. Localization accuracy was quantified for 104 OPM sensors mounted on a fixed helmet array based on simulations and recordings from a bespoke current dipole phantom. Passive shielding attenuated the vector field magnitude to 50.0 nT at direct current (DC), to 16.7 pT/√Hz at power line, and to 71 fT/√Hz (median) in the 10-200 Hz range. Post hoc noise reduction provided an additional 5-15 dB attenuation. Substantial field isotropy remained in the volume encompassing the sensor array. The consistency of the isotropy over months suggests that a field nulling solution could be readily applied. A current dipole phantom generating source activity at an appropriate magnitude for the human brain generated field fluctuations on the order of 0.5-1 pT. Phantom signals were localized with 3 mm localization accuracy, and no significant bias in localization was observed, which is in line with performance for cryogenic and OPM MEG systems. This validation of the performance of a small footprint MEG system opens the door for lower-cost MEG installations in terms of raw materials and facility space, as well as mobile imaging systems (e.g., truck-based). Such implementations are relevant for global adoption of MEG outside of highly resourced research and clinical institutions.

15.
World J Clin Cases ; 12(17): 3177-3182, 2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38898872

RESUMEN

BACKGROUND: Supernumerary phantom limb (SPL) sensation is the experience of additional limbs, either single or a pair of limbs. Unique to traumatic spinal cord injuries, we report effect of transcranial direct current stimulation (tDCS) on SPL pain in a patient with cervical cord injury. CASE SUMMARY: The subject was a 57-year-old man who was diagnosed with complete spinal cord injury (C6/C5, motor level; C5/C5, sensory level; AIS-A) approximately three months ago. After a period of 2 wk, we administered anodal tDCS over the motor cortex for 15 minutes at an intensity of 1.5 mA. Following that treatment, the patient experienced a decrease of SPL pain intensity and frequency, which lasted for 1 week after the end of treatment. CONCLUSION: Targeting the motor cortex through neuromodulation appears to be a promising option for the management of SPL pain.

16.
J Nucl Med Technol ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38901966

RESUMEN

The lack of pediatrics-specific equipment for nuclear medicine imaging has resulted in insufficient diagnostic information for newborns, especially low-birth-weight infants. Although PET offers high spatial resolution and low radiation exposure, its use in newborns is limited. This study investigated the feasibility of cardiac PET imaging using the latest silicon photomultiplier (SiPM) PET technology in infants of extremely low birth weight (ELBW) using a phantom model. Methods: The study used a phantom model representing a 500-g ELBW infant with brain, cardiac, liver, and lung tissues. The cardiac tissue included a 3-mm-thick defect mimicking myocardial infarction. Organ tracer concentrations were calculated assuming 18F-FDG myocardial viability scans and 18F-flurpiridaz myocardial perfusion scans and were added to the phantom organs. Imaging was performed using an SiPM PET/CT scanner with a 5-min acquisition. The data acquired in list mode were reconstructed using 3-dimensional ordered-subsets expectation maximization with varying iterations. Image evaluation was based on the depiction of the myocardial defect compared with normal myocardial accumulation. Results: Increasing the number of iterations improved the contrast of the myocardial defect for both tracers, with 18F-flurpiridaz showing higher contrast than 18F-FDG. However, even at 50 iterations, both tracers overestimated the defect accumulation. A bull's-eye image can display the flow metabolism mismatch using images from both tracers. Conclusion: SiPM PET enabled cardiac PET imaging in a 500-g ELBW phantom with a 1-g heart. However, there were limitations in adequately depicting these defects. Considering the image quality and defect contrast,18F-flurpiridaz appears more desirable than 18F-FDG if only one of the two can be used.

17.
Acta Med Philipp ; 58(9): 44-47, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38836080

RESUMEN

Phantom limb pain (PLP) is difficult to control, and patients frequently exhibit inadequate relief from medications or encounter unbearable side effects. We present here a novel application of erector spinae plane (ESP) block to manage PLP. Our patient is a 23-year-old, college student, diagnosed with high-grade osteosarcoma of the right humerus who underwent a right shoulder disarticulation. He reported PLP despite multimodal analgesia postoperatively. An ESP block using a high-frequency linear probe ultrasound was performed. A G23 spinal needle was advanced in-plane toward the right T3 transverse process. After negative aspiration, 20 mL of therapeutic solution containing bupivacaine 0.25%, lidocaine 1%, epinephrine 5 mcg/ml, and 40 mg methylprednisolone was injected. After the procedure, the patient reported that his PLP went down to NRS 1/10. He consistently reported to have an NRS score of 0-1/10 on succeeding consultations despite discontinuation of opioid and pregabalin. In literature, ESP block has been used as a regional technique for shoulder disarticulation surgery and other neuropathic pain conditions, but no account has shown its use for PLP treatment. The procedure was successfully done to alleviate the upper extremity phantom limb pain, significantly reduce analgesic requirements, and improve tolerance of physical therapy and overall quality of life.

18.
Bioengineering (Basel) ; 11(6)2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38927849

RESUMEN

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

19.
Bioengineering (Basel) ; 11(6)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38927856

RESUMEN

Medical imaging has allowed for significant advancements in the field of ultrasound procedures over the years. However, each imaging modality exhibits distinct limitations that differently affect their accuracy. It is imperative to ensure the quality of each modality to identify and eliminate these limitations. To achieve this, a tissue-mimicking material (TMM) phantom is utilised for validation. This study aims to perform a systematic analysis of tissue-mimicking materials used for creating ultrasound phantoms. We reviewed 234 studies on the use of TMM phantoms in ultrasound that were published from 2013 to 2023 from two research databases. Our focus was on studies that discussed TMMs' properties and fabrication for ultrasound, elastography, and flow phantoms. The screening process led to the selection of 16 out of 234 studies to include in the analysis. The TMM ultrasound phantoms were categorised into three groups based on the solvent used; each group offers a broad range of physical properties. The water-based material most closely aligns with the properties of ultrasound. This study provides important information about the materials used for ultrasound phantoms. We also compared these materials to real human tissues and found that PVA matches most of the human tissues the best.

20.
J Neural Eng ; 21(4)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38885673

RESUMEN

Objective. The insertion of penetrating neural probes into the brain is crucial for advancing neuroscience, yet it involves various inherent risks. Prototype probes are typically inserted into hydrogel-based brain phantoms and the mechanical responses are analyzed in order to inform the insertion mechanics duringin vivoimplantation. However, the underlying mechanism of the insertion dynamics of neural probes in hydrogel brain phantoms, particularly the phenomenon of cracking, remains insufficiently understood. This knowledge gap leads to misinterpretations and discrepancies when comparing results obtained from phantom studies to those observed under thein vivoconditions. This study aims to elucidate the impact of probe sharpness and dimensions on the cracking mechanisms and insertion dynamics characterized during the insertion of probes in hydrogel phantoms.Approach. The insertion of dummy probes with different shank shapes defined by the tip angle, width, and thickness is systematically studied. The insertion-induced cracks in the transparent hydrogel were accentuated by an immiscible dye, tracked byin situimaging, and the corresponding insertion force was recorded. Three-dimensional finite element analysis models were developed to obtain the contact stress between the probe tip and the phantom.Main results. The findings reveal a dual pattern: for sharp, slender probes, the insertion forces remain consistently low during the insertion process, owing to continuously propagating straight cracks that align with the insertion direction. In contrast, blunt, thick probes induce large forces that increase rapidly with escalating insertion depth, mainly due to the formation of branched crack with a conical cracking surface, and the subsequent internal compression. This interpretation challenges the traditional understanding that neglects the difference in the cracking modes and regards increased frictional force as the sole factor contributing to higher insertion forces. The critical probe sharpness factors separating straight and branched cracking is identified experimentally, and a preliminary explanation of the transition between the two cracking modes is derived from three-dimensional finite element analysis.Significance. This study presents, for the first time, the mechanism underlying two distinct cracking modes during the insertion of neural probes into hydrogel brain phantoms. The correlations between the cracking modes and the insertion force dynamics, as well as the effects of the probe sharpness were established, offering insights into the design of neural probes via phantom studies and informing future investigations into cracking phenomena in brain tissue during probe implantations.


Asunto(s)
Encéfalo , Hidrogeles , Fantasmas de Imagen , Hidrogeles/química , Encéfalo/fisiología , Análisis de Elementos Finitos , Estrés Mecánico , Electrodos Implantados