Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-29723117

RESUMEN

Hereditary xanthinuria (type I) is caused by an inherited deficiency of the xanthine oxidorectase (XDH/XO), and is characterized by very low concentration of uric acid in blood and urine and high concentration of urinary xanthine, leading to urolithiasis. Type II results from a combined deficiency of XDH/XO and aldehyde oxidase. Patients present with hematuria, renal colic, urolithiasis or even acute renal failure. Clinical symptoms are the same for both types. In a third type, clinically distinct, sulfite oxidase activity is missing as well as XDH/XO and aldehyde oxidase. The prevalence is not known, but about 150 cases have been described so far. Hypouricemia is sometimes overlooked, that´s why we have set up the diagnostic flowchart. This consists of a) evaluation of uric acid concentrations in serum and urine with exclusion of primary renal hypouricemia, b) estimation of urinary xanthine, c) allopurinol loading test, which enables to distinguish type I and II; and finally assay of xanthine oxidoreductase activity in plasma with molecular genetic analysis. Following this diagnostic procedure we were able to find first patients with hereditary xanthinuria in our Czech population. We have detected nine cases, which is one of the largest group worldwide. Four patients were asymptomatic. All had profound hypouricemia, which was the first sign and led to referral to our department. Urinary concentrations of xanthine were in the range of 170-598 mmol/mol creatinine (normal < 30 mmol/mol creatinine). Hereditary xanthinuria is still unrecognized disorder and subjects with unexplained hypouricemia need detailed purine metabolic investigation.


Asunto(s)
Aldehído Oxidasa/deficiencia , Errores Innatos del Metabolismo/epidemiología , Errores Innatos del Metabolismo de la Purina-Pirimidina/epidemiología , Purinas/metabolismo , Xantina Deshidrogenasa/deficiencia , Xantina Deshidrogenasa/metabolismo , Adulto , Aldehído Oxidasa/sangre , Aldehído Oxidasa/orina , Alopurinol/metabolismo , Niño , Preescolar , República Checa/epidemiología , Diagnóstico Diferencial , Humanos , Errores Innatos del Metabolismo/sangre , Errores Innatos del Metabolismo/diagnóstico , Errores Innatos del Metabolismo/orina , Errores Innatos del Metabolismo de la Purina-Pirimidina/sangre , Errores Innatos del Metabolismo de la Purina-Pirimidina/diagnóstico , Errores Innatos del Metabolismo de la Purina-Pirimidina/orina , Defectos Congénitos del Transporte Tubular Renal/sangre , Defectos Congénitos del Transporte Tubular Renal/epidemiología , Defectos Congénitos del Transporte Tubular Renal/orina , Ácido Úrico/sangre , Ácido Úrico/orina , Cálculos Urinarios/sangre , Cálculos Urinarios/epidemiología , Cálculos Urinarios/orina , Xantina/sangre , Xantina/orina , Xantina Deshidrogenasa/sangre , Xantina Deshidrogenasa/orina
2.
Drug Metab Dispos ; 38(8): 1322-7, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20444863

RESUMEN

The ability to predict in vivo clearance from in vitro intrinsic clearance for compounds metabolized by aldehyde oxidase has not been demonstrated. To date, there is no established scaling method for predicting aldehyde oxidase-mediated clearance using in vitro or animal data. This challenge is exacerbated by the fact that rats and dogs, two of the laboratory animal species commonly used to develop in vitro-in vivo correlations of clearance, differ from humans with regard to expression of aldehyde oxidase. The objective of this investigation was to develop an in vitro-in vivo correlation of intrinsic clearance for aldehyde oxidase, using 11 drugs known to be metabolized by this enzyme. The set consisted of methotrexate, XK-469, (+/-)-4-(4-cyanoanilino)-5,6-dihydro-7-hydroxy-7H-cyclopenta[d]pyrimidine (RS-8359), zaleplon, 6-deoxypenciclovir, zoniporide, O(6)-benzylguanine, N-[(2'-dimethylamino)ethyl]acridine-4-carboxamide (DACA), carbazeran, PF-4217903, and PF-945863. These compounds were assayed using two in vitro systems (pooled human liver cytosol and liver S-9 fractions) to calculate scaled unbound intrinsic clearance, and they were then compared with calculated in vivo unbound intrinsic clearance. The investigation provided a relative scale that can be used for in vitro-in vivo correlation of aldehyde oxidase clearance and suggests limits as to when a potential new drug candidate that is metabolized by this enzyme will possess acceptable human clearance, or when structural modification is required to reduce aldehyde oxidase catalyzed metabolism.


Asunto(s)
Aldehído Oxidasa/metabolismo , Citosol/metabolismo , Hígado/metabolismo , Preparaciones Farmacéuticas/metabolismo , Aldehído Oxidasa/sangre , Humanos , Preparaciones Farmacéuticas/sangre , Unión Proteica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA