Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.115
Filtrar
1.
Bratisl Lek Listy ; 125(6): 347-353, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38757590

RESUMEN

PURPOSE: Standard endovascular aortic aneurysm repair (EVAR) is sometimes the only treatment option for patients with hostile aortic neck anatomy, but it carries an increased risk of both early and late procedure-related complications. The aim of this study was to report on single-center experience with the Heli-FX EndoAnchors (Medtronic, Santa Rosa, CA) as an adjunctive procedure to endovascular aneurysm repair (EVAR) for prevention and perioperative treatment of proximal neck complications in patients with hostile neck anatomy.  MATERIALS AND METHODS: A single-centre, retrospective study evaluating 24 consecutive patients treated with EndoAnchors during the index EVAR procedure between November 2018 and August 2021. EndoAnchor implantation was indicated for cases with hostile proximal aortic neck anatomy characterised by the presence of at least one of the following parameters: length of 28 mm, angle of >60°, circumferential thrombus/calcification involving ≥50%, and reverse taper. RESULTS:  Median follow-up period was 22.5 months (IQR 2-31.5 months) with no aneurysm-related death, rupture, or conversion to open surgical repair during the follow-up. The procedural success rate was 100%, with no type Ia endoleak at the completion angiography. A mean of 7 EndoAnchors was used per patient (range 4-12). There were no EndoAnchor fractures and dislocations or stent graft fabric damage due to anchor implants. Twenty-three patients (95.8%) remained free of type Ia endoleak and migration on follow-up imaging. Aneurysm sac regression was observed in 13 patients (54.1%), while in 8 patients (33.3%) the sac remained stable. Sac enlargement was present in 1 patient (4.2%) due to late type Ia endoleak. Two patients were lost to the follow-up immediately after the procedure. Between two groups of patients (sac regression versus failure to regress), the larger initial diameter of the proximal neck was the only significant independent factor associated with a lower possibility of sac regression (p= 0,021). CONCLUSIONS:  The use of EndoAnchors during the index EVAR procedure in cases with challenging aortic neck anatomy with or without perioperative type Ia endoleak was associated with good midterm results and led to sac regression in most of the patients (Tab. 4, Fig. 3, Ref. 31).


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Procedimientos Endovasculares/métodos , Masculino , Estudios Retrospectivos , Femenino , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/instrumentación , Anciano de 80 o más Años , Complicaciones Posoperatorias/prevención & control , Endofuga/etiología , Endofuga/prevención & control , Resultado del Tratamiento , Prótesis Vascular , Stents
2.
J Cardiothorac Surg ; 19(1): 276, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704597

RESUMEN

BACKGROUND: Conventional graft replacement for a juxtarenal abdominal aortic aneurysm (JRAAA) remains challenging for high-risk patients since it often requires the reconstruction of some visceral arteries. CASE PRESENTATION: A 76-year-old woman was diagnosed with an 87 × 48 mm saccular JRAAA. Open graft replacement was contraindicated because of frailty and a past history of trans-thoracoabdominal esophagectomy. Chimney endovascular aortic repair (ChEVAR) with three chimney endografts was successfully performed without any endoleaks, and each visceral circulation was kept intact. The patient was discharged uneventfully on postoperative day 8. Significant shrinkage of the aneurysmal sac and preservation of flow through each chimney graft were observed on computed tomography 6 months postoperatively, with no significant increase in serum creatinine levels on laboratory testing. CONCLUSIONS: ChEVAR can be a useful surgical option instead of conventional operations, especially for high-risk cases.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Esofagectomía , Humanos , Femenino , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Esofagectomía/efectos adversos , Esofagectomía/métodos , Implantación de Prótesis Vascular/métodos , Tomografía Computarizada por Rayos X , Reparación Endovascular de Aneurismas
3.
Zhonghua Nei Ke Za Zhi ; 63(5): 468-473, 2024 May 01.
Artículo en Chino | MEDLINE | ID: mdl-38715483

RESUMEN

Objective: To examine the perioperative clinical features and prognosis of patients with ruptured abdominal aortic aneurysms (rAAA) who received surgical repair. Methods: The clinical data of rAAA patients who underwent surgical repair and were admitted to the Surgical Intensive Care Unit of Beijing Anzhen Hospital, Capital Medical University from August 2005 to November 2020 were retrospectively analyzed, including the general clinical features, surgical mode, intraoperative conditions, postoperative complications, and fatality rate. Results: There were 117 patients with rAAA, with a median age of 68 (62,77) years, including 93 men (79.5%) and 24 women (20.5%). The main clinical manifestation was abdominal pain (n=115, 98.3%). Among them, 65 (55.6%) patients underwent endovascular aneurysm repair (EVAR), while 52 (44.4%) underwent open surgical repair (OSR). The common postoperative complications include acute gastrointestinal dysfunction (n=116, 99.1%), shock (n=89, 76.1%), acute respiratory distress syndrome (n=85, 72.6%), pancreatic injury (n=56, 47.9%), coagulation dysfunction (n=55, 47.0%), disseminated intravascular coagulation (n=46, 39.3%), acute kidney injury (n=39, 33.3%), infection/sepsis (n=28, 23.9%), gastrointestinal bleeding (n=17, 14.5%), and abdominal compartment syndrome (n=12, 10.3%). The overall postoperative in-hospital fatality rate was 10.3% (12/117). Preoperative use of vasopressors and inotropes, retroperitoneal hematoma, and postoperative abdominal compartment syndrome, gastrointestinal hemorrhage, acute kidney injury, and diffuse intravascular coagulation significantly increased the fatality rate [5/11, 6/24, 5/16, 6/12, 6/17, 23.1%(9/39), 19.6%(9/46), respectively]. Conclusion: The postoperative mortality of rAAA patients is still high in the era of EVAR, especially in patients with preoperative existence of shock and retroperitoneal hematoma, and with postoperative abdominal compartment syndrome, coagulation dysfunction, and acute kidney injury. It is necessary to strengthen perioperative monitoring and management of these patients to reduce the fatality rate.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rotura de la Aorta , Complicaciones Posoperatorias , Humanos , Femenino , Masculino , Aneurisma de la Aorta Abdominal/cirugía , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Rotura de la Aorta/cirugía , Pronóstico , Procedimientos Endovasculares , Análisis de Datos
6.
BMJ Open ; 14(4): e081046, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38626979

RESUMEN

INTRODUCTION: Incisional hernia (IH) is a prevalent and potentially dangerous complication of abdominal surgery, especially in high-risk groups. Mesh reinforcement of the abdominal wall has been studied as a potential intervention to prevent IHs. Randomised controlled trials (RCTs) have demonstrated that prophylactic mesh reinforcement after abdominal surgery, in general, is effective and safe. In patients with abdominal aortic aneurysm (AAA), prophylactic mesh reinforcement after open repair has not yet been recommended in official guidelines, because of relatively small sample sizes in individual trials. Furthermore, the identification of subgroups that benefit most from prophylactic mesh placement requires larger patient numbers. Our primary aim is to evaluate the efficacy and effectiveness of the use of a prophylactic mesh after open AAA surgery to prevent IH by performing an individual patient data meta-analysis (IPDMA). Secondary aims include the evaluation of postoperative complications, pain and quality of life, and the identification of potential subgroups that benefit most from prophylactic mesh reinforcement. METHODS AND ANALYSIS: We will conduct a systematic review to identify RCTs that study prophylactic mesh placement after open AAA surgery. Cochrane Central Register of Controlled Trials, MEDLINE Ovid, Embase, Web of Science Core Collection and Google Scholar will be searched from the date of inception onwards. RCTs must directly compare primary sutured closure with mesh closure in adult patients who undergo open AAA surgery. Lead authors of eligible studies will be asked to share individual participant data (IPD). The risk of bias (ROB) for each included study will be assessed using the Cochrane ROB tool. An IPDMA will be performed to evaluate the efficacy, with the IH rate as the primary outcome. Any signs of heterogeneity will be evaluated by Forest plots. Time-to-event analyses are performed using Cox regression analysis to evaluate risk factors. ETHICS AND DISSEMINATION: No new data will be collected in this study. We will adhere to institutional, national and international regulations regarding the secure and confidential sharing of IPD, addressing ethics as indicated. We will disseminate findings via international conferences, open-source publications in peer-reviewed journals and summaries posted online. PROSPERO REGISTRATION NUMBER: CRD42022347881.


Asunto(s)
Aneurisma de la Aorta Abdominal , Hernia Incisional , Adulto , Humanos , Hernia Incisional/prevención & control , Hernia Incisional/cirugía , Mallas Quirúrgicas , Complicaciones Posoperatorias/etiología , Laparotomía/efectos adversos , Aneurisma de la Aorta Abdominal/cirugía , Revisiones Sistemáticas como Asunto , Metaanálisis como Asunto
7.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635284

RESUMEN

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares , Arteria Ilíaca , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Arteria Ilíaca/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Resultado del Tratamiento , Factores de Riesgo , Prótesis Vascular , Complicaciones Posoperatorias/etiología
8.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635285

RESUMEN

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Complicaciones Posoperatorias , Diseño de Prótesis , Stents , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Masculino , Femenino , Anciano , Factores de Tiempo , Medición de Riesgo , Persona de Mediana Edad
9.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635286

RESUMEN

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Estudios de Factibilidad , Diseño de Prótesis , Stents , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Medios de Contraste , Aortografía
11.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635287

RESUMEN

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Diseño de Prótesis , Sistema de Registros , Humanos , Masculino , Femenino , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Endofuga/etiología , Factores de Tiempo , Resultado del Tratamiento , Anciano de 80 o más Años , Stents , Estudios Retrospectivos , Factores de Riesgo , Etiquetado de Productos , Reparación Endovascular de Aneurismas
12.
Ann Card Anaesth ; 27(2): 162-164, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38607881

RESUMEN

ABSTRACT: We report a case of simultaneous transcatheter aortic valve replacement and endovascular aneurysm repair. Our aim was to advocate the role of local and regional anesthesia as a key contributor in maintaining hemodynamic stability and avoiding abrupt blood pressure change. Endovascular combined procedures are gaining popularity for their numerous advantages. Nevertheless, they carry significant risks for their hemodynamic implications. It is imperative to acknowledge the modifications occurring after each correction and act accordingly. Different anesthesia approaches can dramatically influence hemodynamics; among all, we found local and regional anesthesia would better serve this objective.


Asunto(s)
Anestesia de Conducción , Anestésicos , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Aneurisma de la Aorta Abdominal/cirugía
13.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579061

RESUMEN

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Anciano , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Axila/cirugía , Pierna/cirugía , Procedimientos Endovasculares/métodos , Stents , Resultado del Tratamiento , Aneurisma Ilíaco/cirugía
14.
Langenbecks Arch Surg ; 409(1): 135, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38649506

RESUMEN

OBJECTIVE: Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS: Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS: Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION: This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Ilíaco , Humanos , Masculino , Femenino , Aneurisma Ilíaco/cirugía , Aneurisma Ilíaco/diagnóstico por imagen , Anciano , Procedimientos Endovasculares/métodos , Persona de Mediana Edad , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/patología , Arteria Ilíaca/diagnóstico por imagen , Implantación de Prótesis Vascular/métodos , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
J Cardiothorac Surg ; 19(1): 267, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664759

RESUMEN

BACKGROUND: We explored the clinical significance of miR-28-5p pre- and post-endovascular abdominal aortic aneurysm repair (EVAR) in abdominal aortic aneurysm (AAA) patients. METHODS: Subjects included AAA patients receiving EVAR and non-AAA people without statistical differences from AAA patient in comorbidities/Framingham risk score. Fasting elbow venous blood (4 mL) was collected in the morning of the day of EVAR surgery and in the morning of 3 months post-EVAR. Pre-/post-EVAR serum miR-28-5p expression, AAA maximum diameter alterations, CD3+/CD4+/CD8+/TC/TG pre-/post-EVAR, and the correlations between miR-28-5p and AAA maximum diameter were investigated. Prediction of miR-28-5p on post-EVAR mortality, prognosis, and independent factors of post-EVAR death were analyzed using receiver operating characteristic curve (ROC)/Kaplan-Meier curve/univariable and multivariable Cox regression. According to the cut-off value of ROC curve for postoperative miR-28-5p was the cut-off value, and the patients were classified into the miR-28-5p high- and low-expression groups. The survival or death of both groups were compared after 48-month follow-up. RESULTS: Serum miR-28-5p levels in AAA patients dropped post-EVAR. AAA patients showed notable differences in CD3+/CD4+/CD8+/TC/TG levels pre-/post-EVAR. The miR-28-5p low-expression group exhibited higher CD3+/CD4+ and lower CD8+/TC/TG levels. We observed a positive correlation between post-EVAR miR-28-5p and AAA maximum diameter and between the pre-/post-EVAR miR-28-5p fold change and the AAA maximum diameter change. Postoperative miR-28-5p demonstrated good predictive value for postoperative death. Hypertension, Framingham risk score, TC, TG, and miR-28-5p were independent influencing factors of post-EVAR death. CONCLUSION: EVAR decreased serum miR-28-5p expression in AAA patients. Post-operative miR-28-5p level and pre-/post-operative fold change level are positively-correlated with AAA diameter.


Asunto(s)
Aneurisma de la Aorta Abdominal , Procedimientos Endovasculares , MicroARNs , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/sangre , Aneurisma de la Aorta Abdominal/mortalidad , Masculino , Femenino , MicroARNs/sangre , Anciano , Pronóstico , Periodo Posoperatorio , Persona de Mediana Edad , Valor Predictivo de las Pruebas
16.
Catheter Cardiovasc Interv ; 103(6): 982-994, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584518

RESUMEN

Endovascular aortic repair is an emerging novel intervention for the management of abdominal aortic aneurysms. It is crucial to compare the effectiveness of different access sites, such as transfemoral access (TFA) and upper extremity access (UEA). An electronic literature search was conducted using PubMed, EMBASE, and Google Scholar databases. The primary endpoint was the incidence of stroke/transient ischemic attack (TIA), while the secondary endpoints included technical success, access-site complications, mortality, myocardial infarction (MI), spinal cord ischemia, among others. Forest plots were constructed for the pooled analysis of data using the random-effects model in Review Manager, version 5.4. Statistical significance was set at p < 0.05. Our findings in 9403 study participants (6228 in the TFA group and 3175 in the UEA group) indicate that TFA is associated with a lower risk of stroke/TIA [RR: 0.55; 95% CI: 0.40-0.75; p = 0.0002], MI [RR: 0.51; 95% CI: 0.38-0.69; p < 0.0001], spinal cord ischemia [RR: 0.41; 95% CI: 0.32-0.53, p < 0.00001], and shortens fluoroscopy time [SMD: -0.62; 95% CI: -1.00 to -0.24; p = 0.001]. Moreover, TFA required less contrast agent [SMD: -0.33; 95% CI: -0.61 to -0.06; p = 0.02], contributing to its appeal. However, no significant differences emerged in technical success [p = 0.23], 30-day mortality [p = 0.48], ICU stay duration [p = 0.09], or overall hospital stay length [p = 0.22]. Patients with TFA had a lower risk of stroke, MI, and spinal cord ischemia, shorter fluoroscopy time, and lower use of contrast agents. Future large-scale randomized controlled trials are warranted to confirm and strengthen these findings.


Asunto(s)
Implantación de Prótesis Vascular , Cateterismo Periférico , Reparación Endovascular de Aneurismas , Arteria Femoral , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/métodos , Cateterismo Periférico/métodos , Reparación Endovascular de Aneurismas/métodos , Arteria Femoral/diagnóstico por imagen , Proyectos Piloto , Punciones , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Extremidad Superior/irrigación sanguínea
17.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600502

RESUMEN

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Cirujanos , Femenino , Humanos , Persona de Mediana Edad , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Toracoscopios , Resultado del Tratamiento , Stents , Procedimientos Endovasculares/métodos , Diseño de Prótesis , Aneurisma de la Aorta Abdominal/cirugía
18.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618696

RESUMEN

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Arteria Renal , Stents , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Humanos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Arteria Renal/cirugía , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento , Procedimientos Endovasculares/instrumentación , Diseño de Prótesis , Factores de Riesgo
19.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38551514

RESUMEN

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Endofuga/etiología , Factores de Riesgo , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA