Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.957
Filtrar
1.
Sci Rep ; 14(1): 7758, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38565890

RESUMEN

Knowledge about anatomical details seems to facilitate the procedure and planning of prostatic artery embolization (PAE) in patients with symptomatic benign prostatic hyperplasia (BPS). The aim of our study was the pre-interventional visualization of the prostatic artery (PA) with MRA and the correlation of iliac elongation and bifurcation angles with technical success of PAE and technical parameters. MRA data of patients with PAE were analysed retrospectively regarding PA visibility, PA type, vessel elongation, and defined angles were correlated with intervention time, fluoroscopy time, dose area product (DAP), cumulative air kerma (CAK), contrast media (CM) dose and technical success of embolization. T-test, ANOVA, Pearson correlation, and Kruskal-Wallis test was applied for statistical analysis. Between April 2018 and March 2021, a total of 78 patients were included. MRA identified the PA origin in 126 of 147 cases (accuracy 86%). Vessel elongation affected time for catheterization of right PA (p = 0.02), fluoroscopy time (p = 0.05), and CM dose (p = 0.02) significantly. Moderate correlation was observed for iliac bifurcation angles with DAP (r = 0.30 left; r = 0.34 right; p = 0.01) and CAK (r = 0.32 left; r = 0.36 right; p = 0.01) on both sides. Comparing the first half and second half of patients, median intervention time (125 vs. 105 min.) and number of iliac CBCT could be reduced (p < 0.001). We conclude that MRA could depict exact pelvic artery configuration, identify PA origin, and might obviate iliac CBCT. Vessel elongation of pelvic arteries increased intervention time and contrast media dose while the PA origin had no significant influence on intervention time and/or technical success.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/irrigación sanguínea , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Medios de Contraste , Embolización Terapéutica/métodos , Angiografía por Resonancia Magnética , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Resultado del Tratamiento
2.
Aesthetic Plast Surg ; 48(9): 1698-1705, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38480656

RESUMEN

BACKGROUND: Knowledge of the anatomy of the infraorbital artery (IOA) is crucial for the rejuvenation of the anterior medial aspect of the midface; however, studies adequately describing the anatomy of the IOA branches are lacking, and their connection with the ophthalmic artery branches remains unclear. OBJECTIVES: This study aims to elucidate the anatomical characteristics of the IOA in its deployment within the lower eyelid using three-dimensional (3D) technology, thereby offering an anatomical foundation for clinical surgical procedures. METHODS: An analysis was conducted on computed tomography scans of 132 cadaveric head sides post-contrast injection, utilizing the Mimics software for reconstruction. The study focused on examining the anastomosis of the IOA, its principal branches, and the branches emanating from the ophthalmic artery. RESULTS: The prevalence of type I IOA was observed at 38.6% (51/132), while Type II IOA was found in 61.4% (81/132) of cases. A 7.6% incidence (10/132) of IOA directly anastomosing with the angular artery was noted. The presence of palpebral branches (PIOA) was identified in 57.6% (76/132) of instances. In the lower eyelid, four distinct distribution patterns of IOA were discerned: The likelihood of Type I PIOA was 5.3%, whereas for Types IIA, IIB, and IIC PIOA, the probabilities were 8.3%, 32.6%, and 11.4%, respectively. The occurrence of the orbital branch of IOA was recorded at 41.7% (55/132). CONCLUSIONS: 3D technology can map IOA variants and identify the deployment patterns of IOA branches in the lower eyelid vascular vesicles at high resolution as a guide in clinical practice. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Cadáver , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Femenino , Masculino , Párpados/irrigación sanguínea , Párpados/diagnóstico por imagen , Párpados/anatomía & histología , Órbita/irrigación sanguínea , Órbita/diagnóstico por imagen , Órbita/anatomía & histología , Arteria Oftálmica/anatomía & histología , Arteria Oftálmica/diagnóstico por imagen , Anciano , Persona de Mediana Edad , Variación Anatómica , Anciano de 80 o más Años , Arterias/anatomía & histología , Arterias/diagnóstico por imagen , Relevancia Clínica
3.
Arch Orthop Trauma Surg ; 144(5): 2119-2125, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38492060

RESUMEN

INTRODUCTION: The aim of this study is to assess the risk of peroneal artery injury of hardware placement at the fixation of syndesmotic injuries. MATERIALS AND METHODS: The lower extremity computed tomography angiography was used to design the study. The syndesmosis screw placement range was simulated every 0.5 cm, from 0.5 to 5 cm proximal to the ankle joint. The screw axes were drawn as 20°, 30° or individual angle according to the femoral epicondylar axis. The proximity between the screw axis and the peroneal artery was measured in millimeters. Potential peroneal artery injury was noted if the distance between the peroneal artery to the axis of the simulated screw was within the outer shaft radius of the simulated screw. The Pearson chi-square test was used and a p-value < 0.05 was considered significant. RESULTS: The potential for injury to the peroneal artery increased as the syndesmosis screw level rose proximally from the ankle joint level or as the diameter of the syndesmosis screw increasds. In terms of syndesmosis screw trajection, the lowest risk of injury was observed with the syndesmosis screw angle of 20°. Simulations with a screw diameter of 3.5 mm exhibited the least potential for peroneal artery injury. CONCLUSION: Thanks to this radiological anatomy simulation study, we believe that we have increased the awareness of the peroneal artery potential in syndesmosis screw application. Each syndesmosis screw placement option may have different potential for injury to the peroneal artery. To decrease the peroneal artery injury potential, we recommend the followings. If individual syndesmosis screw angle trajection can be measured, place the screw 1.5 cm proximal to the ankle joint using a 3.5 mm screw shaft. If not, fix it with 30° trajection regardless of the screw diameter at the same level. If the most important issue is the peroneal artery circulation, use the screw level up to 1 cm proximal to the ankle joint regardless of the screw angle trajection and screw diameter.


Asunto(s)
Tornillos Óseos , Angiografía por Tomografía Computarizada , Humanos , Tornillos Óseos/efectos adversos , Angiografía por Tomografía Computarizada/métodos , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control , Lesiones del Sistema Vascular/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/efectos adversos , Traumatismos del Tobillo/cirugía , Traumatismos del Tobillo/diagnóstico por imagen , Arterias/lesiones , Arterias/diagnóstico por imagen , Arterias/anatomía & histología
4.
Vet Radiol Ultrasound ; 65(3): 279-287, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38494832

RESUMEN

Cardiovascular changes have been reported in late pregnancy in mares. However, there are no data on changes in peripheral blood flow. Doppler ultrasound represents a sensitive method for assessing the blood flow directed to the hoof. The aims of this study were to evaluate the blood flow parameters of the lateral palmar digital artery (LPDA) in pregnant mares and to assess intra- and interrater agreement between two observers with different levels of experience. The LPDAs of pregnant Italian Standardbred mares were examined. The vessels were located with B-mode ultrasound and analyzed with color and pulsed wave Doppler. The following parameters were recorded by the operators: heart rate (HR), peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI). Measurements were performed between 2 and 3 months of gestation (T1), in the last month of pregnancy (T2) and a week after delivery (T3). Seventeen mares aged 3-18 years met the inclusion criteria. Ultrasound examinations of the LPDA were subjectively easy to perform and well tolerated by the mares. Interrater and intrarater agreement were good and moderate, respectively. The HR was higher at T2 than at T1 and T3. The PSV and RI changed significantly during pregnancy, with higher values at T2 and T3, whereas the EDV remained unchanged throughout the examination. Doppler examination showed that peripheral flow changes were present in mares in late pregnancy. However, the persistence of higher values after delivery invites further investigation to assess the correlation between metabolic/endocrine changes related to pregnancy and Doppler parameters.


Asunto(s)
Preñez , Animales , Caballos , Femenino , Embarazo , Ultrasonografía Doppler/veterinaria , Arterias/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/veterinaria
6.
Artículo en Chino | MEDLINE | ID: mdl-38548399

RESUMEN

Objective: To explore the cutting scheme and clinical application effects of ultrathin thoracodorsal artery perforator flap assisted by color Doppler ultrasound. Methods: This study was a retrospective historical control study. From February 2017 to October 2019, 20 patients who were admitted to the Third Department of Orthopedics of Xingtai General Hospital of North China Medical and Health Group (hereinafter referred to as our department), met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested based on the surgeon's clinical experience were selected as control group, including 16 males and 4 females, aged (37±5) years. From November 2019 to December 2022, 21 patients who were admitted to our department, met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested under the assistance of color Doppler ultrasound were selected as ultrasound-assisted group, including 15 males and 6 females, aged (38±6) years. After debridement, the area of skin and soft tissue defects of extremities ranged 5.0 cm×4.0 cm to 19.0 cm×8.0 cm, and the area of thoracodorsal artery perforator flaps ranged 6.0 cm×5.0 cm to 20.0 cm×9.0 cm. The wounds in flap donor sites were closed directly. For patients in ultrasound-assisted group, the time and cost required for color Doppler ultrasound examination were recorded, and the number, type, and location of thoracodorsal artery perforator vessels detected by preoperative color Doppler ultrasound were compared with those of intraoperative actual detection. The time required for complete flap harvest of patients in 2 groups was recorded. On postoperative day (POD) 1, 3, 5, 7, and 14, the blood perfusion of flaps in the 2 groups of patients was assessed using a flap perfusion assessment scale. On POD 14, flap survival of patients in 2 groups was observed, and the percentage of flap survival area was calculated. In postoperative 6 months, satisfaction of patients with the treatment outcome in the 2 groups was assessed using 5-grade Likert scale, and the satisfaction rate was calculated. Results: For patients in ultrasound-assisted group, the time required for preoperative color Doppler ultrasound examination was (10.5±2.3) min, and the cost was 120 yuan; 21 thoracodorsal artery perforator vessels were detected and marked using preoperative color Doppler ultrasound, including 8 (38.10%) type 1 perforator vessels, 10 (47.62%) type 2 perforator vessels, and 3 (14.29%) type 3 perforator vessels; the number, type, and location of thoracodorsal artery perforator vessels detected preoperatively were consistent with those detected intraoperatively. The time required for complete flap harvest of patients in ultrasound-assisted group was (41±10) min, which was significantly shorter than (63±12) min in control group (t=6.32, P<0.05). On POD 1, 3, 5, 7, and 14, the blood perfusion scores of flaps of patients in ultrasound-assisted group were significantly better than those in control group (with t values of 6.67, 7.48, 8.03, 8.75, and 7.99, respectively P<0.05). On POD 14, only one patient in ultrasound-assisted group had partial flap necrosis and 6 patients in control group had complete or partial necrosis of the flap; the percentage of flap survival area of patients in ultrasound-assisted group was (99±8)%, which was significantly higher than (87±8)% in control group (t=4.57, P<0.05). In postoperative 6 months, there was no significant difference in the satisfaction rate of patients with the treatment outcome between the two groups (P>0.05). Conclusions: Preoperative color Doppler ultrasound is highly accurate in detecting the number, type, and location of perforator vessels. The cutting scheme of ultrathin thoracodorsal artery perforator flaps can be designed according to the different types of perforator vessels, with shorted flap cutting time and improved flap survival rate.


Asunto(s)
Colgajo Perforante , Procedimientos de Cirugía Plástica , Masculino , Femenino , Humanos , Colgajo Perforante/irrigación sanguínea , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Ultrasonografía Doppler en Color , Necrosis
7.
Radiology ; 310(3): e231877, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38441098

RESUMEN

Background Prostatic artery embolization (PAE) is a safe, minimally invasive angiographic procedure that effectively treats benign prostatic hyperplasia; however, PAE-related patient radiation exposure and associated risks are not completely understood. Purpose To quantify radiation dose and assess radiation-related adverse events in patients who underwent PAE at multiple centers. Materials and Methods This retrospective study included patients undergoing PAE for any indication performed by experienced operators at 10 high-volume international centers from January 2014 to May 2021. Patient characteristics, procedural and radiation dose data, and radiation-related adverse events were collected. Procedural radiation effective doses were calculated by multiplying kerma-area product values by an established conversion factor for abdominopelvic fluoroscopy-guided procedures. Relationships between cumulative air kerma (CAK) or effective dose and patient body mass index (BMI), fluoroscopy time, or radiation field area were assessed with linear regression. Differences in radiation dose stemming from radiopaque prostheses or fluoroscopy unit type were assessed using two-sample t tests and Wilcoxon rank sum tests. Results A total of 1476 patients (mean age, 69.9 years ± 9.0 [SD]) were included, of whom 1345 (91.1%) and 131 (8.9%) underwent the procedure with fixed interventional or mobile fluoroscopy units, respectively. Median procedure effective dose was 17.8 mSv for fixed interventional units and 12.3 mSv for mobile units. CAK and effective dose both correlated positively with BMI (R2 = 0.15 and 0.17; P < .001) and fluoroscopy time (R2 = 0.16 and 0.08; P < .001). No radiation-related 90-day adverse events were reported. Patients with radiopaque implants versus those without implants had higher median CAK (1452 mGy [range, 900-2685 mGy] vs 1177 mGy [range, 700-1959 mGy], respectively; P = .01). Median effective dose was lower for mobile than for fixed interventional systems (12.3 mSv [range, 8.5-22.0 mSv] vs 20.4 mSv [range, 13.8-30.6 mSv], respectively; P < .001). Conclusion Patients who underwent PAE performed with fixed interventional or mobile fluoroscopy units were exposed to a median effective radiation dose of 17.8 mSv or 12.3 mSv, respectively. No radiation-related adverse events at 90 days were reported. © RSNA, 2024 See also the editorial by Mahesh in this issue.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Exposición a la Radiación , Humanos , Masculino , Anciano , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Estudios Retrospectivos , Próstata/diagnóstico por imagen , Arterias/diagnóstico por imagen
8.
Br J Radiol ; 97(1156): 838-843, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38379411

RESUMEN

OBJECTIVES: To evaluate the clinical value of using a split-bolus contrast injection protocol in improving image quality consistency and diagnostic accuracy in lower extremity CT angiography (CTA). METHODS: Fifty (mean age, 66 ± 12 years) and 39 (mean age, 66 ± 11 years) patients underwent CTA in the lower extremity arteries using split-bolus and fixed-bolus injection schemes, respectively. The objective and subjective image quality of the 2 groups were compared and the diagnostic efficacy for the degree of vessel stenosis was compared using digital subtraction angiography as the gold standard. A P < .05 was considered statistically significant. RESULTS: In comparison with the fixed-bolus scheme, the split-bolus scheme greatly improved the consistency of image quality of the low extremities by significantly increasing the arterial enhancement (337.87 ± 64.67HU vs. 254.74 ± 71.58HU, P < .001), signal-to-noise ratio (22.58 ± 11.64 vs. 7.14 ± 1.98, P < .001), and contrast-to-noise ratio (37.21 ± 10.46 vs. 31.10 ± 15.40, P = .041) in the infrapopliteal segment. The subjective image quality was better (P < .001) and the diagnostic accuracy was higher in the split-bolus group than in the fixed-bolus group (96.00% vs. 91.67%, P < .05, for diagnosing >50% stenosis, and 97.00% vs. 89.10%, P < .05, for diagnosing occlusion) for the infrapopliteal segment arteries. CONCLUSIONS: Compared with the fixed-bolus injection scheme, the split-bolus injection scheme improves the image quality consistency and diagnostic accuracy especially for the infrapopliteal segment arteries in lower extremity CTA. ADVANCES IN KNOWLEDGE: (1) The split-bolus injection scheme of CTA of the lower extremity arteries improves the overall image quality, uniformity of contrast enhancement. (2) Compared with the fixed-bolus injection scheme, the split-bolus injection scheme especially improves the infrapopliteal segment arteries image quality and diagnostic efficacy.


Asunto(s)
Arterias , Angiografía por Tomografía Computarizada , Humanos , Persona de Mediana Edad , Anciano , Angiografía por Tomografía Computarizada/métodos , Constricción Patológica , Angiografía de Substracción Digital/métodos , Arterias/diagnóstico por imagen , Extremidad Inferior/diagnóstico por imagen , Extremidad Inferior/irrigación sanguínea , Medios de Contraste
9.
Surg Radiol Anat ; 46(5): 665-668, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413475

RESUMEN

In most cases, the superior laryngeal artery (SLA) branches from the superior thyroid artery, which, in turn, leaves the external carotid artery. Few dissection studies found previously that the SLA could originate from the lingual artery. We report here probably the first evidence of such a rare anatomical variation found unilaterally in a retrospectively evaluated by computed tomography angiography adult male case. The left SLA left a suprahyoid coil of the lingual artery and continued over the greater hyoid horn to enter the larynx through the thyrohyoid membrane. On both sides, thyroid foramina were found, but only the right one used for the entry of the right SLA. Therefore, the rare SLA origin from the lingual artery can be documented on computed tomography angiograms, which could help during preoperative evaluations and prevent unwanted surgical complications.


Asunto(s)
Variación Anatómica , Angiografía por Tomografía Computarizada , Laringe , Humanos , Masculino , Laringe/irrigación sanguínea , Laringe/anomalías , Laringe/diagnóstico por imagen , Arterias/anomalías , Arterias/diagnóstico por imagen , Arterias/anatomía & histología , Glándula Tiroides/irrigación sanguínea , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/anomalías , Persona de Mediana Edad , Lengua/irrigación sanguínea , Lengua/diagnóstico por imagen , Lengua/anomalías , Estudios Retrospectivos
10.
J Ultrasound Med ; 43(6): 1045-1051, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38356337

RESUMEN

OBJECTIVES: The aim of this study was to establish the relationship of facial artery with nasolabial fold by color Doppler sonography and to determine facial artery variations and their relationship with age, gender, or hemifaces. METHODS: The study included 188 patients (94 women, 94 men) aged 18-60 years. Overall, 376 facial arteries in both hemifaces were evaluated for the course within nasolabial fold, symmetry, and relationship with gender. RESULTS: The mean age of the patients was 39.29 ± 12.81 years. Type A (55.7%) was the most common type in both hemifaces. There was no significant relationship between the course of facial artery and age (P > .05). Asymmetrical course of facial artery was more common in females (54.3%). In both genders, type A was the type with highest symmetry detected. CONCLUSIONS: Nasolabial fold is one of the important facial regions for filler injection. To prevent vascular injection, course of facial artery should be identified within the nasolabial fold. Type A was the most common type in both hemifaces and genders. Although the rates were close to each other, asymmetry in the course of the facial artery was observed in most of the patients. Ultrasonographic examination which is non-invasive and non-ionizing imaging method can be performed carefully before filler injection to determine vascular tissues.


Asunto(s)
Arterias , Cara , Surco Nasolabial , Ultrasonografía Doppler en Color , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Adolescente , Surco Nasolabial/diagnóstico por imagen , Adulto Joven , Cara/irrigación sanguínea , Cara/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Arterias/diagnóstico por imagen , Factores Sexuales
11.
Magn Reson Med ; 91(6): 2320-2331, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38173296

RESUMEN

PURPOSE: Background suppression (BS) is recommended in arterial spin labeling (ASL) for improved SNR but is difficult to optimize in existing velocity-selective ASL (VSASL) methods. Dual-module VSASL (dm-VSASL) enables delay-insensitive, robust, and SNR-efficient perfusion imaging, while allowing efficient BS, but its optimization has yet to be thoroughly investigated. METHODS: The inversion effects of the velocity-selective labeling pulses, such as velocity-selective inversion (VSI), can be used for BS, and were modeled for optimizing BS in dm-VSASL. In vivo experiments using dual-module VSI (dm-VSI) were performed to compare two BS strategies: a conventional one with additional BS pulses and a new one without any BS pulse. Their BS performance, temporal noise, and temporal SNR were examined and compared, with pulsed and pseudo-continuous ASL (PASL and PCASL) as the reference. RESULTS: The in vivo experiments validated the BS modeling. Strong positive linear correlations (r > 0.82, p < 0.0001) between the temporal noise and the tissue signal were found in PASL/PCASL and dm-VSI. Optimal BS can be achieved with and without additional BS pulses in dm-VSI; the latter improved the ASL signals by 8.5% in gray matter (p = 0.006) and 12.2% in white matter (p = 0.014) and tended to provide better temporal SNR. The dm-VSI measured significantly higher ASL signal (p < 0.016) and temporal SNR (p < 0.018) than PASL and PCASL. Complex reconstruction was found necessary with aggressive BS. CONCLUSION: Guided by modeling, optimal BS can be achieved without any BS pulse in dm-VSASL, further improving the ASL signal and the SNR performance.


Asunto(s)
Angiografía por Resonancia Magnética , Sustancia Blanca , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Arterias/diagnóstico por imagen , Sustancia Gris , Circulación Cerebrovascular , Encéfalo/diagnóstico por imagen
12.
Vasc Endovascular Surg ; 58(5): 512-522, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38271562

RESUMEN

Introduction: Median Arcuate Ligament Syndrome (MALS) is associated with true aneurysms, mainly of both the pancreaticoduodenal artery (PDA) and gastroduodenal artery (GDA). Although rare, their potential for rupture and adverse clinical outcomes warrants analysis. Prior studies suggest high rupture rates even for smaller aneurysms under 2 cm in this setting. We performed a systematic literature review, synthesising the evidence on visceral artery aneurysms related to MAL syndrome, with a focus on descriptive analyses of aneurysm size, presentation, rupture rates, and management. Methods: Literature search was performed using (Medline, EMBASE, Emcare and CINAHL). Inclusion criteria included true aneurysms secondary to MALS with or without rupture. The cases with pseudoaneurysms, concomitant pathologies eg, pancreatitis, conservatively managed aneurysms and articles with non-granular pooled data were excluded. Cases were assessed according to demographics, clinical presentation, aneurysm diameter, aneurysm rupture and management technique. Results: 39 articles describing 72 patients were identified. Aneurysm diameter in symptomatic patients was not significantly different from asymptomatic patients {21.0 and 22.3 mm respectively, P = .84}. Ruptured aneurysms were overall smaller than non-ruptured at presentation {12.3 mm v 30.8 mm respectively, P = .02}. Patients presented with abdominal pain (75.6%), nausea/vomiting (15.6%), hypotension (33.9%), shock (20.0%) and haemodynamic collapse (8.9%). 56.9% of all cases were managed with an endovascular approach, 19.4% were managed with an open surgical approach, and 23.6% were managed hybrid. Conclusion: This review suggests visceral artery aneurysms associated with median arcuate ligament rupture at variable sizes. Despite inability to clearly correlate size and rupture risk, our data supports prompt intervention irrespective of size, given the adverse outcomes. Further research is critically needed to clarify size thresholds or other predictors to guide management.


Asunto(s)
Aneurisma Roto , Aneurisma , Síndrome del Ligamento Arcuato Medio , Humanos , Síndrome del Ligamento Arcuato Medio/complicaciones , Síndrome del Ligamento Arcuato Medio/cirugía , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Resultado del Tratamiento , Factores de Riesgo , Aneurisma Roto/cirugía , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/etiología , Femenino , Persona de Mediana Edad , Masculino , Anciano , Adulto , Arterias/diagnóstico por imagen , Procedimientos Endovasculares , Anciano de 80 o más Años , Vísceras/irrigación sanguínea , Medición de Riesgo
13.
Magn Reson Med ; 91(4): 1384-1403, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38181170

RESUMEN

PURPOSE: To present a theoretical framework that rigorously defines and analyzes key concepts and quantities for velocity selective arterial spin labeling (VSASL). THEORY AND METHODS: An expression for the VSASL arterial delivery function is derived based on (1) labeling and saturation profiles as a function of velocity and (2) physiologically plausible approximations of changes in acceleration and velocity across the vascular system. The dependence of labeling efficiency on the amplitude and effective bolus width of the arterial delivery function is defined. Factors that affect the effective bolus width are examined, and timing requirements to minimize quantitation errors are derived. RESULTS: The model predicts that a flow-dependent negative bias in the effective bolus width can occur when velocity selective inversion (VSI) is used for the labeling module and velocity selective saturation (VSS) is used for the vascular crushing module. The bias can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal cutoff velocity of the vascular crushing module. CONCLUSION: The elements of the model are specified in a general fashion such that future advances can be readily integrated. The model can facilitate further efforts to understand and characterize the performance of VSASL and provide critical theoretical insights that can be used to design future experiments and develop novel VSASL approaches.


Asunto(s)
Arterias , Angiografía por Resonancia Magnética , Marcadores de Spin , Arterias/diagnóstico por imagen , Modelos Teóricos , Aceleración , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología
14.
Plast Reconstr Surg ; 153(3): 706-711, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37104463

RESUMEN

BACKGROUND: The purpose of this study was to determine the distribution of the angular artery (AA) in the medial canthal area with the aim of defining an arterial course to prevent AA injury during facial surgery in this region. METHODS: The authors dissected 36 hemifaces of 18 cadavers. The horizontal distance from the vertical level through the medial canthus to the AAs was measured. The AA course of each specimen was then recorded, and all of them were then superimposed to determine the AA course. The diameter and depth of the AA around the medial canthal area were also investigated using ultrasonography on living subjects. RESULTS: The horizontal distances from the medial canthus level and 2 cm below the medial canthus were 9.0 ± 2.0 mm (mean ± SD) and 1.9 ± 2.4 mm, respectively. The superimposed image demonstrated that most of the AAs were present inside the vertical line through the medial canthus. Ultrasonography indicated that the AA was 2.3 ± 0.9 mm below the skin and 1.7 ± 0.3 mm in diameter. CONCLUSIONS: The AA course was relatively constant along the nasojugal fold. The AAs were most often present between the middle of the medial canthus and the facial midline, but were very scarce in both the medial and lateral thirds. Knowledge of the detailed course of the AA may help surgeons to avoid arterial injury and decrease the risk of surgical morbidities around the nasal root and medial canthal area.


Asunto(s)
Aparato Lagrimal , Lesiones del Sistema Vascular , Humanos , Cara/diagnóstico por imagen , Cara/cirugía , Nariz/irrigación sanguínea , Ultrasonografía , Arterias/diagnóstico por imagen
15.
Cir Esp (Engl Ed) ; 102(2): 69-75, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37949364

RESUMEN

INTRODUCTION: While haemorrhoidal dearterialization and mucopexy are accepted as a valid alternative to haemorrhoidectomy, differences exist regarding the fixed or variable location of the arteries to be ligated. Our aim was to shed light on this issue of arterial distribution in candidates for surgery. METHODS: The study included consecutive patients diagnosed with Goligher grade III and IV haemorrhoids, who had undergone Doppler-guided haemorrhoidal artery ligation (DG-HAL) and rectoanal repair (RAR) at 2 medical centres in Spain. The main objective was to evaluate the number and 12-h clock locations of arterial ligatures necessary to achieve Doppler silence. RESULTS: In total, 146 patients were included: 111 (76%) men, and 35 (24%) women. Average age was 54 years (21-84). Grade III and grade IV haemorrhoids were diagnosed in 106 (72.6%) and 40 (27.4%) patients, respectively. The average number of ligatures per patient was 7 (range 2-12). Ligature percentages greater than 60% occurred at clock positions 7, 11, 10, 12, 9, and 1. The average number of mucopexies per patient was 3 (range 1-4). The most frequent mucopexy locations were the left posterior, right posterior, and right anterior octants. CONCLUSIONS: While the greatest frequency of arterial ligatures occurred in odd-numbered clock positions, non-negligible percentages occurred in even-numbered clock positions, which, in our opinion, makes the use of Doppler necessary, given that arterial distribution is not the same in all patients. We also noted that more ligatures and mucopexies were needed on the right half of the rectal circumference than on the left side, suggesting greater right-side vascularization.


Asunto(s)
Hemorreoidectomía , Hemorroides , Masculino , Humanos , Femenino , Persona de Mediana Edad , Hemorroides/diagnóstico por imagen , Hemorroides/cirugía , Ultrasonografía Intervencional , Recto/diagnóstico por imagen , Recto/cirugía , Recto/irrigación sanguínea , Arterias/diagnóstico por imagen , Arterias/cirugía
16.
Folia Morphol (Warsz) ; 83(1): 53-65, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37144850

RESUMEN

BACKGROUND: The inferior gluteal artery (IGA) is a large terminal branch of the anterior division of the internal iliac artery (ADIIA). There is a significant lack of data regarding the variable anatomy of the IGA. MATERIALS AND METHODS: A retrospective study was conducted to establish anatomical variations, their prevalence and morphometrical data on IGA and its branches. The results of 75 consecutive patients who underwent pelvic computed tomography angiography were analysed. RESULTS: The origin variation of each IGA was deeply analysed. Four origin variations have been observed. The most common type O1 occurred in 86 of the studied cases (62.3%). The median IGA length was set to be 68.50 mm (lower quartile [LQ]: 54.29; higher quartile [HQ]: 86.06). The median distance from the origin of the ADIIA to the origin of the IGA was set to be 38.22 mm (LQ: 20.22; HQ: 55.97). The median origin diameter of the IGA was established at 4.69 mm (LQ: 4.13; HQ: 5.45). CONCLUSIONS: The present study thoroughly analysed the complete anatomy of the IGA and the branches of the ADIIA. A novel classification system for the origin of the IGA was created, where the most prevalent origin was from the ADIIA (type 1; 62.3%). Furthermore, the morphometric properties (such as the diameter and length) of the branches of the ADIIA were analysed. This data may be incredibly useful for physicians performing operations in the pelvis, such as interventional intraarterial procedures or various gynaecological surgeries.


Asunto(s)
Cirugía Plástica , Humanos , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Arterias/anatomía & histología , Pelvis/diagnóstico por imagen , Nalgas/diagnóstico por imagen , Nalgas/irrigación sanguínea , Inmunoglobulina A
17.
MAGMA ; 37(1): 53-68, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37768433

RESUMEN

OBJECTIVES: One challenge in arterial spin labeling (ASL) is the high variability of arterial transit times (ATT), which causes associated arterial transit delay (ATD) artifacts. In patients with pathological changes, these artifacts occur when post-labeling delay (PLD) and bolus durations are not optimally matched to the subject, resulting in difficult quantification of cerebral blood flow (CBF) and ATT. This is also true for the free lunch approach in Hadamard-encoded pseudocontinuous ASL (H-pCASL). MATERIAL AND METHODS: Five healthy volunteers were scanned with a 3 T MR-system. pCASL-subbolus timing was adjusted individually by the developed adaptive Walsh-ordered pCASL sequence and an automatic feedback algorithm. The quantification results for CBF and ATT and the respective standard deviations were compared with results obtained using recommended timings and intentionally suboptimal timings. RESULTS: The algorithm individually adjusted the pCASL-subbolus PLD for each subject within the range of recommended timing for healthy subjects, with a mean intra-subject adjustment deviation of 47.15 ms for single-shot and 44.5 ms for segmented acquisition in three repetitions. DISCUSSION: A first positive assessment of the results was performed on healthy volunteers. The extent to which the results can be transferred to patients and are of benefit must be investigated in follow-up studies.


Asunto(s)
Arterias , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Marcadores de Spin , Reproducibilidad de los Resultados , Arterias/diagnóstico por imagen , Circulación Cerebrovascular/fisiología
18.
Am J Hypertens ; 37(1): 24-32, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37638873

RESUMEN

BACKGROUND: Preeclampsia (PE) is associated with increased cardiovascular risk. Recent data have shown worse left ventricular remodeling and diastolic function in women with PE and persistent hypertension (HTN). We performed a comprehensive arterial hemodynamic assessment to evaluate the contribution of persistent HTN on arterial health after PE. METHODS: We recruited 40 women with PE history and 40 age-matched controls (6 months to 6 years postpartum). We evaluated arterial hemodynamics with validated techniques combining applanation tonometry and transthoracic echocardiography, comparing three groups: previous PE with persistent HTN (PE-HTN), previous PE with normalized blood pressure (PE-noHTN) and controls, using multivariable linear regression adjusted for age, body surface area, heart rate, diabetes, smoking history, creatinine, and gravidity. RESULTS: Eight (20%) of the post-PE women had persistent HTN. Mean age was 35.8 ±â€…3.9 years, median number of pregnancies was 2 (range 1-7), and time since last pregnancy 2.1 (range 0.5-5.7) years (not different between groups, P > 0.05). Compared to controls and to PE-noHTN, PE-HTN had higher aortic stiffness, wave reflections, pulsatile, and steady arterial load (P < 0.05 for each). Among PE-noHTN, aortic stiffness, wave reflections and steady arterial load were worse than controls (P < 0.05 for each), with smaller effect sizes. CONCLUSIONS: This is the most comprehensive assessment of arterial hemodynamics and first to demonstrate the contribution of persistent HTN on worse arterial health following PE. Since measures of arterial health are associated with cardiovascular events in the population, the combination of previous PE and chronic HTN may represent a higher risk subgroup who could benefit from targeted prevention strategies.


Asunto(s)
Hipertensión , Preeclampsia , Rigidez Vascular , Embarazo , Humanos , Femenino , Adulto , Preeclampsia/diagnóstico , Preeclampsia/epidemiología , Arterias/diagnóstico por imagen , Presión Sanguínea/fisiología , Envejecimiento , Rigidez Vascular/fisiología
19.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38008376

RESUMEN

PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Exposición a la Radiación , Masculino , Humanos , Embolización Terapéutica/efectos adversos , Próstata/diagnóstico por imagen , Próstata/irrigación sanguínea , Estudios Retrospectivos , Hiperplasia Prostática/terapia , Arterias/diagnóstico por imagen , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Programas Informáticos , Tomografía Computarizada de Haz Cónico/efectos adversos , Tomografía Computarizada de Haz Cónico/métodos , Dosis de Radiación , Fluoroscopía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA