Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 939
Filtrar
1.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(9): 1065-1070, 2024 Sep 15.
Artículo en Chino | MEDLINE | ID: mdl-39300880

RESUMEN

Objective: To analyze the effectiveness of tuberosity suture combined with autogenous bone grafting in reverse total shoulder arthroplasty for elderly patients with proximal humerus fracture. Methods: A clinical data of 28 patients with fresh proximal humerus fractures, who met the selection criteria and admitted between June 2014 and April 2022, was retrospectively analyzed. There were 7 males and 21 females. Age ranged from 65 to 81 years, with an average of 73.8 years. The causes of injury were 21 cases of fall, 6 cases of traffic accident, and 1 case of falling from height. The time from injury to operation ranged from 5 to 20 days with an average of 9.2 days. There were 8 cases of Neer three-part fracture and 20 cases of four-part fracture. The reverse total shoulder arthroplasty was performed, and the greater and lesser tuberosities were sutered and reconstructed with autogenous bone grafting. After operation, the Constant score, American Society for Shoulder Surgery (ASES) score, and visual analogue scale (VAS) score were used to evaluate shoulder function and pain; and the active range of motion of the shoulder joint was recorded, including flexion, external rotation, and internal rotation. X-ray films were taken to observe the position of prosthesis. According to the evaluation criteria proposed by Boileau, the healing of greater tuberosity was evaluated, and the effectiveness was compared between the patients with healed and non-healed (displacement and absorption) greater tuberosity. Results: All incisions healed by first intention after operation. All patients were followed up 24-106 months, with an average of 60.9 months. At last follow-up, the VAS score of shoulder joint ranged from 0 to 6 (mean, 1.1). The Constant score ranged from 45 to 100 (mean, 80.1). The ASES score ranged from 57 to 100 (mean, 84.7). The active range of motions of shoulder joint were 60°-160° (mean, 118°) in flexion, 0°-50° (mean, 30°) in external rotation, and corresponding to reaching the S 5-T 8 vertebral body level in internal rotation. During follow-up, no shoulder joint re-dislocation or severe shoulder instability occurred, and no revision surgery was performed. X-ray film reexamination showed that there was no loosening of the prosthesis. According to the evaluation criteria proposed by Boileau, the greater tuberosity fused in 22 cases (78.6%), displaced in 3 cases (10.7%), and absorbed in 3 cases (10.7%). The shoulder joint function and pain related evaluation indicators in the healed group were significantly better than those in the non-healed group ( P<0.05). Conclusion: Tuberosity suture combined with autogenous bone grafting is a relatively simple procedure that provides a reliable fixation for the anatomic recovery of greater and lesser tuberosities and is beneficial for the recovery of shoulder function in elderly patients with proximal humeral fractures.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Trasplante Óseo , Rango del Movimiento Articular , Fracturas del Hombro , Articulación del Hombro , Humanos , Masculino , Femenino , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Fracturas del Hombro/cirugía , Trasplante Óseo/métodos , Articulación del Hombro/cirugía , Anciano de 80 o más Años , Trasplante Autólogo , Resultado del Tratamiento , Suturas , Húmero/cirugía , Técnicas de Sutura
2.
BMC Musculoskelet Disord ; 25(1): 752, 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39304857

RESUMEN

BACKGROUND: Insufficient tuberosity healing is the most common reason for poor outcome after treatment of proximal humerus fractures (PHFs) using hemiarthroplasty (HA). In these cases, revision to reverse total shoulder arthroplasty (RTSA) can improve function and reduce pain in the short term, however, long-term results remain scarce. Aim of this study was to evaluate the clinical and radiological mid- to long-term results in patients with a revision RTSA after failed HA for PHF. METHODS: In this retrospective study all patients that received a revision to RTSA after failed fracture HA between 2006 and 2018 were included. A total of 49 shoulders in 48 patients (38 female, 10 male; mean age 82 ± 9 years) were identified in our database. A total of 20 patients (17 female, 3 male; mean age was 79 ± 9 years) were available for follow-up examination after a mean time period of approximately eight years (3-14 years) after revision surgery. At final follow-up, patients were assessed using a subjective shoulder value (SSV), range of motion (ROM), visual analogue score (VAS), the Constant Score (CS) and the 12-Item Short Form Survey (SF-12). RESULTS: At final follow-up, mean CS was 55 ± 19 (19-91), VAS averaged 3 ± 3 (0-8) and mean SSV was 61 ± 18% (18-90%). Mean SF-12 was 44 (28-57) with a mean physical component summary (PCS) of 38 (21-56) and a mean mental component summary (MCS) of 51 (29-67). On average active forward flexion (FF) was 104° (10-170°), active abduction (ABD) was 101° (50-170°), active external rotation (ER) was 19° (10-30°) and active internal rotation (IR) of the lumbosacral transition was reached. Three patients presented with a periprosthetic humeral fracture after RTSA implantation and underwent a reoperation (15%) during follow-up period. CONCLUSIONS: Revision RTSA results in promising clinical results in patients after initial failed HA after PHF. A complication and reoperation rate of 15% is tolerable in consideration of satisfactory functional and psychological outcome. TRIAL REGISTRATION: Retrospectively registered.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Hemiartroplastia , Rango del Movimiento Articular , Reoperación , Fracturas del Hombro , Humanos , Femenino , Masculino , Anciano , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Estudios Retrospectivos , Artroplastía de Reemplazo de Hombro/métodos , Anciano de 80 o más Años , Hemiartroplastia/métodos , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Articulación del Hombro/diagnóstico por imagen , Estudios de Seguimiento , Insuficiencia del Tratamiento , Resultado del Tratamiento
3.
J Orthop Traumatol ; 25(1): 40, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225941

RESUMEN

With the rising prevalence of shoulder arthroplasty, the incidence of revision shoulder arthroplasty is also increasing. The complexity of these revision procedures poses significant challenges, with bone loss being a critical factor impacting treatment outcomes. Addressing substantial humeral bone defects is crucial for ensuring implant stability and functionality. A comprehensive literature review was conducted using PubMed, Medline, and Google Scholar to identify existing classification systems for proximal humeral bone loss in the context of revision shoulder arthroplasty. The study assessed the advantages and limitations of these classifications, using this information to propose a new diagnostic and therapeutic algorithm. Several classification systems for proximal humeral bone loss were identified. McLendon et al. classify proximal humeral bone loss based on a 5-cm bone loss threshold and suggest an allograft prosthesis composite for losses exceeding this limit. Boileau's system stratifies bone loss into four types based on the extent of loss, with specific recommendations for each category. The PHAROS classification provides a detailed anatomical assessment but lacks quantitative precision. The proposed PHBL-SCORe system offers a novel algorithm incorporating preoperative radiographic measurements to determine the percentage of bone loss and guide treatment options. Proximal humeral bone loss presents significant challenges in revision shoulder arthroplasty, necessitating precise preoperative planning and classification to guide surgical intervention. Existing classification systems provide valuable frameworks but often rely on average population values, neglecting individual anatomical variations. The proposed PHBL-SCORe system offers a patient-specific approach, improving the accuracy of bone loss assessment and optimizing treatment strategies. Implementing this classification in clinical practice could enhance surgical outcomes and reduce complications associated with rRSA (revision Reverse Shoulder arthroplasty). Further studies are required to validate this algorithm and explore its long-term efficacy in diverse patient populations.


Asunto(s)
Algoritmos , Artroplastía de Reemplazo de Hombro , Húmero , Reoperación , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Húmero/cirugía , Húmero/diagnóstico por imagen
4.
BMC Musculoskelet Disord ; 25(1): 709, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39232737

RESUMEN

INTRODUCTION: In reverse shoulder arthroplasty (RSA) new designs enable greater amounts of lateralization to prevent instability and scapular notching and increase range of motion, however, excessive lateralization leads to stress upon the acromion that can result in scapular spine fatigue fractures. Aim of this study was to gender- and size-specifically assess the influence of glenosphere size and different humeral designs on lateralization, distalization, and bony impingement-free range of motion (ROM) in patients undergoing RSA. METHODS: Computed tomography scans from 30 osteoarthritic patients (f:15, m:15) and 20 cuff tear arthropathy patients (f:10, m:10) were used to virtually simulate RSA implantation. The efficacy of an inlay Grammont-type system vs. an onlay lateralizing system combined with different glenosphere sizes (36 mm vs. 42 mm) in achieving ROM, lateralization, and distalization was evaluated. Moreover, gender and patient's constitution were correlated to humeral size by radiologically measuring the best-fit circle of the humeral head. RESULTS: A different amount of relative lateralization was achieved in both genders using large glenospheres and onlay designs. Latter yielded a higher ROM in all planes for men and women with a 42 mm glenosphere; with the 36 mm glenosphere, an increased ROM was observed only in men. The 155° inlay design led to joint medialization only in men, whereas all designs led to lateralization in women. When adjusting the absolute amount of lateralization to humerus' size (or patient's height), regardless of implant type, women received greater relative lateralization using 36 mm glenosphere (inlay: 1%; onlay 12%) than men with 42 mm glenosphere (inlay: -3%; onlay: 8%). CONCLUSION: The relative lateralization achieved using onlay design is much higher in women than men. Small glenospheres yield greater relative lateralization in women compared to large glenospheres in men. Humeral lateralization using onlay designs should be used cautiously in women, as they lead to great relative lateralization increasing stress onto the acromion. LEVEL OF EVIDENCE: Basic Science Study, Computer Modeling.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Diseño de Prótesis , Rango del Movimiento Articular , Articulación del Hombro , Prótesis de Hombro , Humanos , Femenino , Masculino , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/instrumentación , Anciano , Persona de Mediana Edad , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Factores Sexuales , Osteoartritis/cirugía , Osteoartritis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano de 80 o más Años , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/diagnóstico por imagen
5.
Clin Orthop Surg ; 16(4): 602-609, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39092307

RESUMEN

Background: This study evaluated national trends in cemented and uncemented reverse shoulder arthroplasty (RSA) for proximal humerus fractures using a comprehensive national surgical database. This study aimed to compare RSA used in the treatment of proximal humerus fractures with the literature and to determine the country's trend. Methods: A cross-sectional study was conducted using the health records of individuals aged ≥ 18 years who underwent RSA for proximal humerus fractures between 2016 and 2022. Patients were divided into cemented and uncemented groups, and demographic data (age, sex), duration of hospital stay, transfusions, revisions, mortality, and Charlson Comorbidity Index (CCI) scores were analyzed. Results: A total of 618 cemented RSA and 1,364 uncemented RSA procedures were reviewed. Patients who underwent cemented RSA were significantly older than those who had uncemented RSA (p = 0.002). Transfusion rates were higher in the cemented RSA group (p = 0.006). The frequency of revision surgery was 6.1%. Younger age and male sex were associated with revision (p < 0.001). CCI scores were higher among transfused patients than non-transfused patients (p < 0.001). The incidence of cemented RSA was 11.7% and 49% in 2016 and 2022, respectively. Differences were found among hospital types and geographical regions. Conclusions: While cemented RSA has been gaining attention and increased application in recent years for proximal humerus fractures, uncemented RSA still predominates. The choice between these 2 methods is largely influenced by regional and hospital-level factors. The type of RSA and high CCI scores were found to have no significant impact on the risk of surgical revision.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cementos para Huesos , Fracturas del Hombro , Humanos , Masculino , Fracturas del Hombro/cirugía , Femenino , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/estadística & datos numéricos , Anciano , Estudios Transversales , Persona de Mediana Edad , Anciano de 80 o más Años , Adulto , Reoperación/estadística & datos numéricos , Estudios Retrospectivos
6.
Artículo en Inglés | MEDLINE | ID: mdl-39137406

RESUMEN

PURPOSE: The purpose of this study was to evaluate clinical outcomes after tendon transfers in the setting of reverse total shoulder arthroplasty (RTSA). METHODS: PubMed and Embase were searched according to Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines to find primary clinical studies of any type of tendon transfer in the setting of RTSA. RESULTS: Overall, 17 studies (level of evidence [LOE] I: 1, LOE II: 0, LOE III: 3, LOE IV: 13) met inclusion criteria, with 300 shoulders. Most patients were female (56.7%), with an average age of 68.7 years (range 19 to 89) and a mean follow-up of 46.2 months (range 6 to 174). 11 studies reported outcomes after combined latissimus dorsi and teres major transfer (LDTM) while eight studies reported on latissimus dorsi transfer only (LD). Improvements in commonly reported subjective and functional outcome measures were as follows: external rotation +32° (LDTM) and +30° (LD), flexion +65° (LDTM) and +59° (LD), Visual Analog Score -5.4 (LDTM) and -4.5 (LD), subjective shoulder value +43.8% (LDTM) and +46.3% (LD), and overall Constant score +33.8 (LDTM) and +38.7 (LD). The overall complication rate was 11.3%, including tendon transfer ruptures (0.7%), instability (3.0%), infection (2.0%), and nerve injury (0.3%). The all-cause repeat operation rate was 7.3%, most commonly for arthroplasty revision (5.3%). Subgroup analysis revealed that lateralized implants with tendon transfer resulted in markedly greater improvements in Constant score, flexion, ER1, and ER2 while medialized implants with tendon transfer had markedly greater improvements in Visual Analog Score, subjective shoulder value, and abduction. CONCLUSION: Patients undergoing tendon transfer of either combined LDTM or latissimus dorsi alone in the setting of RTSA have markedly improved subjective and functional outcomes. A moderate incidence of complications (11.3%) was noted in this patient population.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Transferencia Tendinosa , Humanos , Transferencia Tendinosa/métodos , Artroplastía de Reemplazo de Hombro/métodos , Rango del Movimiento Articular , Resultado del Tratamiento , Articulación del Hombro/cirugía , Femenino
8.
Orthop Clin North Am ; 55(4): 489-502, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39216954

RESUMEN

Reverse total shoulder arthroplasty (RSA) was historically reserved for the elderly, low-demand patient with rotator cuff arthropathy (RCA) or as a salvage procedure after failed primary arthroplasty. Surgeon expertise and the advancement of implant design has allowed RSA to now become commonplace not only for RCA but also for glenohumeral osteoarthritis. RSA provides a robust glenoid baseplate fixation, which allows for easier and more reliable bone grafting or augmentation when needed. For patients with severe glenoid bone loss, RSA has been shown to have superior or equivalent patient-reported outcomes and shoulder range of motion when compared with total shoulder arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Rango del Movimiento Articular , Diseño de Prótesis , Resultado del Tratamiento
9.
Med Sci Monit ; 30: e945241, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39182164

RESUMEN

BACKGROUND Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff insufficiency and proximal humerus fractures in 22 patients from a single center. MATERIAL AND METHODS Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. RESULTS The mean follow-up duration was 4.05±1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8±2.8 to 81.3±5.4 (p<0.001). VAS Pain Score: Decreased from 7.3±1 to 2.9±0.9 (p<0.001). DASH Score: Improved from 66.3±4.3 to 32.5±3.6 (p<0.001). Constant-Murley Score: Increased from 48.3±3.5 to 74.6±7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). CONCLUSIONS When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Fracturas del Hombro , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/efectos adversos , Fracturas del Hombro/cirugía , Manguito de los Rotadores/cirugía , Anciano de 80 o más Años , Lesiones del Manguito de los Rotadores/cirugía , Resultado del Tratamiento , Rango del Movimiento Articular , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología
10.
Acta Orthop ; 95: 463-471, 2024 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189259

RESUMEN

BACKGROUND AND PURPOSE: We aimed to report the survival of different reverse shoulder arthroplasty (RSA) designs and brands, and factors associated with revision. The secondary aim was to evaluate the reasons for revision. METHODS: We included 4,696 inlay and 798 onlay RSAs reported to the Norwegian Arthroplasty Register (NAR) 2007-2022. Kaplan-Meier estimates of survivorship and Cox models adjusted for age, sex, diagnosis, implant design, humeral fixation, and previous surgery were investigated to assess revision risks. The reasons for revision were compared using competing risk analysis. RESULTS: Overall, the 10-year survival rate was 94% (confidence interval [CI] 93-95). At 5 years all brands exceeded 90%. Compared with Delta Xtend (n = 3,865), Aequalis Ascend Flex (HR 2.8, CI 1.7-4.6), Aequalis Reversed II (HR 2.2, CI 1.2-4.2), SMR (HR 2.5, CI 1.3-4.7), and Promos (HR 2.2, CI 1.0-4.9) had increased risk of revision. Onlay and inlay RSAs had similar risk of revision (HR 1.2, CI 0.8-1.8). Instability and deep infection were the most frequent revision causes. Male sex (HR 2.3, CI 1.7-3.1), fracture sequelae (HR 3.1, CI 2.1-5.0), and fractures operated on with uncemented humeral stems had increased risk of revision (HR 3.5, CI 1.6-7.3). CONCLUSION: We found similar risk of revision with inlay and onlay designs. Some prosthesis brands had a higher rate of revision than the most common implant, but numbers were low.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Prótesis de Hombro , Humanos , Reoperación/estadística & datos numéricos , Masculino , Femenino , Noruega , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Anciano , Persona de Mediana Edad , Estudios de Seguimiento , Prótesis de Hombro/efectos adversos , Anciano de 80 o más Años , Adulto
11.
Acta Orthop ; 95: 386-391, 2024 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016083

RESUMEN

BACKGROUND AND PURPOSE: There is controversy regarding the results of stemmed and stemless total shoulder arthroplasty (TSA) used for osteoarthritis. Therefore, we aimed to compare revision rates of stemmed and stemless TSA and to examine the impact of metal-backed glenoid components. METHODS: We included all patients reported to the Danish Shoulder Arthroplasty Register from January 1, 2012 to December 31, 2022 with an anatomical TSA used for osteoarthritis. Primary outcome was revision (removal or exchange of components) for any reason. RESULTS: 3,338 arthroplasties were included. The hazard ratio for revision of stemless TSA adjusted for age and sex was 1.83 (95% confidence interval [CI] 1.21-2.78) with stemmed TSA as reference. When excluding all arthroplasties with a metal-backed glenoid component, the adjusted hazard ratio for revision of stemless TSA was 1.37 (CI 0.85-2.20). For the Eclipse stemless TSA system, the adjusted hazard ratio for revision of a metal-backed glenoid component was 8.75 (CI 2.40-31.9) with stemless Eclipse with an all-polyethylene glenoid component as reference. CONCLUSION: We showed that the risk of revision of stemless TSAs was increased and that it was related to their combination with metal-backed glenoid components.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Reoperación/estadística & datos numéricos , Masculino , Femenino , Anciano , Dinamarca/epidemiología , Persona de Mediana Edad , Osteoartritis/cirugía , Estudios de Cohortes , Articulación del Hombro/cirugía , Anciano de 80 o más Años , Metales
12.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(5): 967-973, 2024 May 20.
Artículo en Chino | MEDLINE | ID: mdl-38862455

RESUMEN

OBJECTIVE: To develop the'E-Bone', a comprehensive one-stop preoperative planning system for reverse total shoulder arthroplasty with improved accuracy and efficiency. METHODS: The nnU-net deep neural network was utilized for scapula segmentation to obtain precise scapula segmentation results. Based on the 3 key factors, namely bone density, upward and downward angle and nail length, the base was automatically positioned. The quantitative parameters required for surgical planning were calculated. A personalized guide plate was generated by combining glenoid morphology and base positioning information. The system interface was developed to modularize various functions for easy use, providing interactive operation and real-time display. RESULTS: Compared with the Mimics system, the'E-bone'preoperative planning system reduced complex manual adjustments during the planning process. The average planned nail length was longer than that of the Mimics system, and the planning time was reduced by 86%. The scapula segmentation accuracy of this system reached 99.93%, better than that of Mimics to achieve a higher precision. CONCLUSION: The"E-bone"system provides a one-stop, efficient, and accurate preoperative planning system for reverse shoulder replacement and potentially broader clinical applications.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Redes Neurales de la Computación , Escápula/cirugía , Cirugía Asistida por Computador/métodos
13.
BMC Musculoskelet Disord ; 25(1): 449, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38844899

RESUMEN

BACKGROUND: Patient-specific aiming devices (PSAD) may improve precision and accuracy of glenoid component positioning in total shoulder arthroplasty, especially in degenerative glenoids. The aim of this study was to compare precision and accuracy of guide wire positioning into different glenoid models using a PSAD versus a standard guide. METHODS: Three experienced shoulder surgeons inserted 2.5 mm K-wires into polyurethane cast glenoid models of type Walch A, B and C (in total 180 models). Every surgeon placed guide wires into 10 glenoids of each type with a standard guide by DePuy Synthes in group (I) and with a PSAD in group (II). Deviation from planned version, inclination and entry point was measured, as well as investigation of a possible learning curve. RESULTS: Maximal deviation in version in B- and C-glenoids in (I) was 20.3° versus 4.8° in (II) (p < 0.001) and in inclination was 20.0° in (I) versus 3.7° in (II) (p < 0.001). For B-glenoid, more than 50% of the guide wires in (I) had a version deviation between 11.9° and 20.3° compared to ≤ 2.2° in (II) (p < 0.001). 50% of B- and C-glenoids in (I) showed a median inclination deviation of 4.6° (0.0°-20.0°; p < 0.001) versus 1.8° (0.0°-4.0°; p < 0.001) in (II). Deviation from the entry point was always less than 5.0 mm when using PSAD compared to a maximum of 7.7 mm with the standard guide and was most pronounced in type C (p < 0.001). CONCLUSION: PSAD enhance precision and accuracy of guide wire placement particularly for deformed B and C type glenoids compared to a standard guide in vitro. There was no learning curve for PSAD. However, findings of this study cannot be directly translated to the clinical reality and require further corroboration.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Curva de Aprendizaje , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/instrumentación , Hilos Ortopédicos , Cavidad Glenoidea/cirugía , Modelos Anatómicos , Articulación del Hombro/cirugía
14.
J Am Acad Orthop Surg ; 32(15): e777-e784, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38857595

RESUMEN

INTRODUCTION: Reverse total shoulder arthroplasty (RTSA) with structural bone graft has been described as a technique in addressing glenoid bony defects. Studies have demonstrated acceptable outcomes with structural autograft or allograft. However, most of these studies are relatively small and rarely evaluate bone graft incorporation with CT scan. The aim of this study was to assess clinical and radiographic outcomes and report graft incorporation assessed on CT scan after RTSA where structural bone autograft or allograft was used to reconstruct the glenoid. METHODS: From May 2011 through June 2016, 38 patients underwent RTSA with structural bone graft. Of these, 35 were available for a minimum 2-year follow-up and retrospectively enrolled. From July 2016 through February 2019, 32 patients undergoing RTSA with structural bone graft were prospectively enrolled. Preoperative and postoperative American Shoulder and Elbow Surgeons and visual analog scale (for pain) scores and radiographs were obtained. CT scan was obtained at least 1 year postoperatively. RESULTS: Thirty-five patients were enrolled retrospectively (52.2%) and 32 prospectively (47.8%). Autograft was used in 46 cases (68.7%) and allograft in 21 cases. The mean American Shoulder and Elbow Surgeons score improved from 33.1 (SD 18.5) to 78.2 (SD 22.4), with P < 0.0001. On postoperative radiographs, 63 cases (94.0%) showed stable RTSA constructs while four cases (6.0%) developed glenoid baseplate subsidence. Postoperative CT scan demonstrated complete graft incorporation in 45 cases (90.0%) while partial incorporation was noted in 4 cases (8.0%), and in 1 case (2.0%), there was no graft incorporation. No correlation was observed between baseplate subsidence and graft type (autograft versus allograft) or primary versus revision surgery. DISCUSSION: Reverse shoulder arthroplasty with structural bone autograft and allograft is reliable for glenoid augmentation in patients undergoing RTSA in both primary and revision settings. Bony incorporation of autograft and allograft as evaluated on CT scan is predictably high.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Trasplante Óseo , Tomografía Computarizada por Rayos X , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Trasplante Óseo/métodos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Aloinjertos , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Autoinjertos , Trasplante Autólogo
15.
Iowa Orthop J ; 44(1): 99-103, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919361

RESUMEN

Background: Postoperative radiographs may be performed on different timelines after shoulder arthroplasty. Radiographs obtained in the post-operative recovery unit (PACU) are often of poorer quality. The purpose of the current study was to explore and compare the quality of PACU radiographs and radiographs performed in the radiology suite on post-operative Day 1 (POD1), as well as determine their impact on changes in post-operative management. Methods: Our series included 50 consecutive anatomic total shoulder arthroplasties (TSA) for which post-operative radiographs were obtained in the PACU and 50 consecutive TSA for which post-operative radiographs were obtained in the radiology suite on POD 1. TSA radiographs were blinded and reviewed by 3 authors and graded on their quality using criteria described using previously published methods. The weighted kappa was used to describe the intra-rater agreement and inter-rater agreement between two raters. Results: There was no difference in age, sex, BMI, and comorbidities between cohorts. Intra-observer reliability was moderate to substantial with weighted kappa values of 0.65±0.07 (p<0.001), 0.58±0.09 (p<0.001), and 0.67±0.07 (p<0.001). Inter-observer reliability was moderate to substantial with weighted kappa values of 0.605±0.07 (p<0.001), 0.66±0.07 (p<0.001), and 0.65±0.08 (p<0.001). When assessing quality of radiographs, 30% of radiographs obtained in PACU were deemed quality while 57% of radiographs obtained in the radiology suite were deemed quality (p<0.001). Conclusion: Post-operative radiographs in the PACU do not alter patient management and are often inadequate to serve as baseline radiographs. Conversely, radiographs obtained in the radiology suite are of higher quality and can serve as a superior baseline radiograph. Level of Evidence: IV.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Radiografía , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Masculino , Femenino , Radiografía/métodos , Anciano , Sala de Recuperación , Persona de Mediana Edad , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Cuidados Posoperatorios , Periodo Posoperatorio , Estudios Retrospectivos , Factores de Tiempo , Reproducibilidad de los Resultados
16.
J ISAKOS ; 9(4): 620-627, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38851325

RESUMEN

BACKGROUND: Reverse shoulder arthroplasty (RSA) offers promising functional outcomes for young patients, yet challenges persist in restoring internal rotation (IR). This study aimed to assess the restoration of IR after RSA in patients younger than 60 years of age and analyze the factors affecting IR recovery. METHODS: A retrospective multicenter study was conducted, examining the functional outcome of patients who underwent RSA, with a minimum follow-up period of 2 years. Two subgroups of patients who underwent primary RSA were analyzed separately with respect to active internal rotation with the elbow at the side (AIR1): "difficult AIR1" and "easy AIR1." RESULTS: The study included 136 patients (overall series) with a mean age of 51.6 years. The overall series showed statistically significant improvement in active range of motion (RoM), pain, and Constant scores, especially with active IR (p â€‹< â€‹0.01). According to etiology, statistically significant improvement (p â€‹< â€‹0.05) in active IR was observed for fracture sequelae, primary osteoarthritis, and rheumatoid arthritis, whereas no statistically significant improvement in IR was observed for tumor, revision, and cuff-tear arthropathy (p â€‹> â€‹0.05). In subgroup analysis, patients with easy AIR1 displayed a statistically significant lower body mass index and better Constant score mobility, as well as improved motion in forward elevation and active IR (p â€‹< â€‹0.05). No statistically significant associations were found between improved IR and prosthetic design or subscapularis repair. Scapular notch, lysis of the graft, and teres minor atrophy were significantly associated with better active IR (p â€‹< â€‹0.05). CONCLUSION: RSA improves active RoM, pain, and functional outcomes in patients aged under 60. However, the degree of improvement in IR may vary depending on several factors and the underlying etiologies. These insights are crucial for patient selection and counseling, guiding RSA optimization efforts. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Rango del Movimiento Articular , Articulación del Hombro , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Resultado del Tratamiento , Adulto , Factores de Edad , Recuperación de la Función , Estudios de Seguimiento , Osteoartritis/cirugía , Rotación
17.
Acta Orthop ; 95: 348-357, 2024 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-38888103

RESUMEN

BACKGROUND AND PURPOSE: International variation exists in the types of shoulder replacement used for treatment of specific diseases. Implant choice continues to evolve without high-quality evidence. Our aim was to evaluate trends in incidence rates of shoulder replacement and assess any recent changes in practice between countries by using registry data. METHODS: Patient characteristics, indication and year of surgery, type of replacement, and collection methods of patient-reported outcomes (PROMs) was extracted from 11 public joint registries. Meta-analyses examined use of reverse total shoulder replacement (RTSR) for osteoarthritis, cuff tear arthropathy, and acute fracture; use of anatomical total shoulder replacement (TSR) for osteoarthritis; and use of humeral hemiarthroplasty for fracture. RESULTS: The annual growth rate of shoulder replacements performed is 6-15% (2011-2019). The use of RTSR has almost doubled (93%). RTSR is now universally performed for cuff tear arthropathy (97.3%, 95% confidence interval [CI] 96.0-98.1). Its use for avascular necrosis, trauma, and inflammatory arthropathy is increasing. The use of RTSR was similar (43.1%, CI 30.0-57.2) versus TSR (44.7%, CI 31.1-59.1) for osteoarthritis. The types of PROMs used, collection time points, and response rates lack standardization. COVID-19 had a varying inter-registry impact on incidence rates. CONCLUSION: The incidence of shoulder replacements has grown. Use of RTSR has increased for all disease indications despite limited high-quality evidence driving this change in indications outside of cuff arthropathy. Consequently, less variation is observed in international practice. Existing differences now relate to use of newer implant types and methodology of PROMs collection, which prevents international comparison and outcome analysis.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Sistema de Registros , Humanos , Artroplastía de Reemplazo de Hombro/tendencias , Artroplastía de Reemplazo de Hombro/estadística & datos numéricos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Osteoartritis/cirugía , Osteoartritis/epidemiología , Artropatía por Desgarro del Manguito de los Rotadores/cirugía , Artropatía por Desgarro del Manguito de los Rotadores/epidemiología , Hemiartroplastia/tendencias , Hemiartroplastia/métodos , Hemiartroplastia/estadística & datos numéricos
18.
Arch Orthop Trauma Surg ; 144(7): 3103-3111, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38847836

RESUMEN

BACKGROUND: Reverse shoulder arthroplasty (RSA) is a frequently used therapy for complex proximal humeral fractures and posttraumatic disorders. The present study's purpose was to assess the clinical and radiological outcome of primary and secondary RSA, and to analyze the impact of refixation of the greater tuberosity (GT). PATIENTS AND METHODS: 28 patients with primary fracture RSA and 18 patients with RSA due to posttraumatic disorders were examined with a mean clinical follow-up of 2.5 ± 1.73 years. Operative details and radiographs were retrospectively reviewed. Additional analyses were performed for healed and non-healed GT in primary RSA. RESULTS: Patients with fracture RSA had higher Constant-Murley score (CMS) than secondary RSA without reaching significance (p = 0.104). No significant difference was present for the quality of life measured by the Short Form 36 (SF 36) and the range of motion. In primary RSA, 78.6% GT healed anatomically. Compared to non-healed GT, patients with healed GT had a significantly higher CMS (p = 0.011), external rotation (p = 0.026) and forward flexion (p = 0.083), whereas DASH score was lower without a significant difference (p = 0.268). SF 36 showed no significant difference. Patients with healed GT had a more neutral glenoid version (p = 0.009). CONCLUSION: Superior range of motion and clinical outcome scores were present for anatomically healed GT. Therefore, refixation of the tuberosities is recommended. Secondary RSA can result in inferior results compared to primary RSA, so patients need to be adequately informed.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas del Hombro , Humanos , Masculino , Femenino , Artroplastía de Reemplazo de Hombro/métodos , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Radiografía , Resultado del Tratamiento , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Rango del Movimiento Articular , Anciano de 80 o más Años , Adulto
19.
Int Orthop ; 48(7): 1815-1820, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38750258

RESUMEN

PURPOSE: The purpose of this study is to identify risk factors for delays in planned total shoulder arthroplasty (TSA) and determine the perioperative outcomes of TSAs that experienced a delay. METHODS: The American College of Surgeons National Quality Improvement Program (NSQIP) database was queried from 2006 to 2019 for primary TSA. Delayed TSA was defined as surgery that occurred greater than one day after hospital admission. Patient demographics, comorbidities, and post-operative complications were collected and compared; the incidence of delayed TSA was analyzed. RESULTS: The delayed patients were older, had a higher BMI, a higher rate of recent prior major surgery, and more comorbidities. Delayed patients had higher rates of postoperative complications, return to the OR, and 30-day readmission. Between 2006 and 2019, the rate of delayed TSA decreased. CONCLUSION: Surgeons should take care to ensure that patients with comorbidities undergo thorough preoperative clearance to prevent same-day cancellations and postoperative complications.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Procedimientos Quirúrgicos Electivos , Complicaciones Posoperatorias , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/efectos adversos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Electivos/efectos adversos , Procedimientos Quirúrgicos Electivos/métodos , Factores de Riesgo , Tiempo de Tratamiento/estadística & datos numéricos , Resultado del Tratamiento , Estudios Retrospectivos , Anciano de 80 o más Años , Comorbilidad
20.
J Am Acad Orthop Surg ; 32(15): 681-691, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713872

RESUMEN

While several proximal humerus fractures treated nonsurgically reach satisfactory outcomes, some become symptomatic malunions or nonunions with pain and dysfunction. When joint-preserving options such as malunion or nonunion repair are not optimal because of poor remaining bone stock or glenohumeral arthritis, shoulder arthroplasty is a good option. Because of the semiconstrained design of reverse shoulder arthroplasty, it is effective at improving function when there is notable bony deformity or a torn rotator cuff. Clinical studies have demonstrated reliable outcomes, and a classification system exists that is helpful for predicting prognosis and complications. By understanding the associated pearls and pitfalls and with careful management of the tuberosities, reverse shoulder arthroplasty is a powerful tool for managing proximal humerus fracture sequelae.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Fracturas Mal Unidas/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA