Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.246
Filtrar
1.
Transl Vis Sci Technol ; 13(5): 11, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38748408

RESUMEN

Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.


Asunto(s)
Simulación por Computador , Córnea , Análisis de Elementos Finitos , Queratectomía Fotorrefractiva , Humanos , Córnea/cirugía , Córnea/fisiología , Queratectomía Fotorrefractiva/métodos , Simulación por Computador/normas , Láseres de Excímeros/uso terapéutico , Modelos Biológicos
2.
J Biomech ; 169: 112145, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38761745

RESUMEN

To investigate the optimal cutting depth (Cap) in small incision lenticule extraction from the perspective of corneal biomechanics, a three-dimensional finite element model of the cornea was established using a stromal sub-regional material model to simulate small incision lenticule extraction. The displacement difference PΔ at the central point of the posterior corneal surface before and after lenticule extraction, as well as the von Mises stress at four points of different thicknesses in the center of the cornea, were analyzed using the finite element model considering the hyperelastic property and the difference in stiffness between the anterior and posterior of the cornea. The numerical curves of PΔ-Cap and von Mises Stress-Cap relations at different diopters show that the displacement difference PΔ has a smallest value at the same diopter. In this case, the von Mises stress at four points with different thicknesses in the center of the cornea was also minimal. Which means that the optimal cutting depth exsisting in the cornea. Moreover, PΔ-Cap curves for different depth of stromal stiffness boundaries show that the optimal cap thickness would change with the depth of the stromal stiffness boundary. These results are of guiding significance for accurately formulating small incision lenticule extraction surgery plans and contribute to the advancement of research on the biomechanical properties of the cornea.


Asunto(s)
Córnea , Análisis de Elementos Finitos , Modelos Biológicos , Humanos , Córnea/cirugía , Córnea/fisiología , Córnea/fisiopatología , Fenómenos Biomecánicos , Sustancia Propia/cirugía , Estrés Mecánico , Cirugía Laser de Córnea/métodos , Simulación por Computador
3.
J Biomech ; 169: 112155, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38761746

RESUMEN

Acute alcohol ingestion has been found to impact visual functions, including eye movement, but its effects on corneal biomechanical properties remain unclear. This study aimed to investigate the influence of acute alcohol consumption on corneal biomechanical properties using optical coherence elastography (OCE). An air-coupled ultrasound transducer induced elastic waves in mice corneas in vivo, and a high-resolution phase-sensitive optical coherence tomography (OCT) system tracked the mechanical waves to quantify the elastic wave speed. In vivo measurements were performed on three groups of age- and gender-matched mice: control, placebo (administered saline), and alcohol (administered ethanol) groups. Longitudinal measurements were conducted over a one-hour period to assess acute temporal changes in wave speeds, which are associated with inherent biomechanical properties of the cornea. The results showed a significant decrease in wave speed for the alcohol group after 10 min of ingestion in comparison to pre-ingestion values (p = 0.0096), whereas the temporal wave speed changes for the placebo group were statistically insignificant (p = 0.076). In contrast, the control group showed no significant changes in elastic wave speed and corneal thickness. Furthermore, a significant difference was observed between the wave speeds of the placebo and alcohol groups at each measurement time point between 10 and 50 min (p < 0.05), though both groups exhibited a similar trend in corneal thickness change. The findings of this study have important implications for clinical assessments and research in corneal disorders, highlighting the potential of OCE as a valuable tool for evaluating such changes.


Asunto(s)
Consumo de Bebidas Alcohólicas , Córnea , Diagnóstico por Imagen de Elasticidad , Córnea/diagnóstico por imagen , Córnea/fisiología , Animales , Diagnóstico por Imagen de Elasticidad/métodos , Ratones , Consumo de Bebidas Alcohólicas/fisiopatología , Fenómenos Biomecánicos , Masculino , Tomografía de Coherencia Óptica/métodos , Etanol , Ratones Endogámicos C57BL , Elasticidad , Femenino
4.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776117

RESUMEN

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Asunto(s)
Córnea , Presión Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Córnea/diagnóstico por imagen , Córnea/fisiología , Presión Intraocular/fisiología , Fenómenos Biomecánicos/fisiología , Anciano , Persona de Mediana Edad , Esclerótica/fisiología , Esclerótica/diagnóstico por imagen , Masculino , Femenino , Glaucoma/fisiopatología , Anciano de 80 o más Años , Donantes de Tejidos , Adulto
5.
Opt Lett ; 49(10): 2817-2820, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748169

RESUMEN

Alteration in the elastic properties of biological tissues may indicate changes in the structure and components. Acoustic radiation force optical coherence elastography (ARF-OCE) can assess the elastic properties of the ocular tissues non-invasively. However, coupling the ultrasound beam and the optical beam remains challenging. In this Letter, we proposed an OCE method incorporating homolateral parallel ARF excitation for measuring the elasticity of the ocular tissues. An acoustic-optic coupling unit was established to reflect the ultrasound beam while transmitting the light beam. The ARF excited the ocular tissue in the direction parallel to the light beam from the same side of the light beam. We demonstrated the method on the agar phantoms, the porcine cornea, and the porcine retina. The results show that the ARF-OCE method can measure the elasticity of the cornea and the retina, resulting in higher detection sensitivity and a more extensive scanning range.


Asunto(s)
Córnea , Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Tomografía de Coherencia Óptica , Diagnóstico por Imagen de Elasticidad/métodos , Animales , Porcinos , Córnea/diagnóstico por imagen , Córnea/fisiología , Tomografía de Coherencia Óptica/métodos , Elasticidad , Retina/diagnóstico por imagen , Retina/fisiología
6.
J Biomech ; 168: 112113, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38648717

RESUMEN

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.


Asunto(s)
Microscopía de Fuerza Atómica , Animales , Microscopía de Fuerza Atómica/métodos , Ratones , Ratas , Esclerótica/fisiología , Esclerótica/diagnóstico por imagen , Córnea/fisiología , Córnea/diagnóstico por imagen , Malla Trabecular/fisiología , Malla Trabecular/diagnóstico por imagen , Crioultramicrotomía/métodos , Disco Óptico/diagnóstico por imagen , Disco Óptico/fisiología , Fenómenos Biomecánicos
7.
BMC Ophthalmol ; 24(1): 155, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594682

RESUMEN

INTRODUCTION: In recent years, insulin eye drops have attracted increasing attention from researchers and ophthalmologists. The aim of this study was to investigate the efficacy and possible mechanism of action of insulin eye drops in diabetic mice with corneal wounds. METHODS: A type 1 diabetes model was induced, and a corneal epithelial injury model of 2.5 mm was established. We used corneal fluorescein staining, hematoxylin-eosin (H-E) staining and the Cochet-Bonnet esthesiometer to examine the process of wound healing. Subsequently, the expression levels of Ki-67, IL-1ß, ß3-tubulin and neuropeptides, including substance P (SP) and calcitonin gene-related peptide (CGRP), were examined at 72 h after corneal injury. RESULTS: Fluorescein staining demonstrated an acceleration of the recovery of corneal epithelial injury in diabetic mice compared with the saline treatment, which was further evidenced by the overexpression of Ki-67. Moreover, 72 h of insulin application attenuated the expression of inflammatory cytokines and neutrophil infiltration. Remarkably, the results demonstrated that topical insulin treatment enhanced the density of corneal epithelial nerves, as well as neuropeptide SP and CGRP release, in the healing cornea via immunofluorescence staining. CONCLUSIONS: Our results indicated that insulin eye drops may accelerate corneal wound healing and decrease inflammatory responses in diabetic mice by promoting nerve regeneration and increasing levels of neuropeptides SP and CGRP.


Asunto(s)
Lesiones de la Cornea , Diabetes Mellitus Experimental , Epitelio Corneal , Queratitis , Ratones , Animales , Epitelio Corneal/metabolismo , Insulina , Diabetes Mellitus Experimental/complicaciones , Diabetes Mellitus Experimental/tratamiento farmacológico , Diabetes Mellitus Experimental/metabolismo , Péptido Relacionado con Gen de Calcitonina/metabolismo , Soluciones Oftálmicas , Antígeno Ki-67/metabolismo , Córnea/fisiología , Lesiones de la Cornea/tratamiento farmacológico , Cicatrización de Heridas , Queratitis/metabolismo , Fluoresceína/metabolismo , Inflamación/metabolismo
8.
Int Ophthalmol ; 44(1): 1, 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38315313

RESUMEN

PURPOSE: Idiopathic normal pressure hydrocephalus (iNPH) is associated with an increased prevalence of open-angle glaucoma, attributed to variations of the pressure gradient between intraocular and intracranial compartments at the level of the lamina cribrosa (LC). As ocular biomechanics influence the behavior of the LC, and a lower corneal hysteresis (CH) has been associated to a higher risk of glaucomatous optic nerve damage, in this study we compared ocular biomechanics of iNPH patients with healthy subjects. METHODS:  Twenty-four eyes of 24 non-shunted iNPH patients were prospectively recruited. Ocular biomechanical properties were investigated using the ocular response analyzer (Reichert Instruments) for the calculation of the CH, corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). Results were compared with those of 25 eyes of 25 healthy subjects. RESULTS:  In iNPH eyes, the median CH value and interquartile range (IQR) were 9.7 mmHg (7.8-10) and 10.6 mmHg (9.3-11.3) in healthy controls (p = 0.015). No significant differences were found in IOPcc [18.1 mmHg (14.72-19.92) vs. 16.4 mmHg (13.05-19.6)], IOPg [15.4 mmHg (12.82-19.7) vs. 15.3 mmHg (12.55-17.35)], and CRF [9.65 mmHg (8.07-11.65) vs. 10.3 mmHg (9.3-11.5)] between iNPH patients and controls. CONCLUSIONS:  In iNPH patients, the CH was significantly lower compared to healthy subjects. This result suggests that ocular biomechanical properties may potentially contribute to the risk of development of glaucomatous optic nerve damage in iNPH patients.


Asunto(s)
Glaucoma de Ángulo Abierto , Hidrocéfalo Normotenso , Traumatismos del Nervio Óptico , Humanos , Hidrocéfalo Normotenso/complicaciones , Presión Intraocular , Tonometría Ocular/métodos , Córnea/fisiología , Fenómenos Biomecánicos , Elasticidad
9.
Prog Retin Eye Res ; 99: 101234, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38176611

RESUMEN

The cornea, as a dynamic and responsive tissue, constantly interacts with mechanical forces in order to maintain its structural integrity, barrier function, transparency and refractive power. Cells within the cornea sense and respond to various mechanical forces that fundamentally regulate their morphology and fate in development, homeostasis and pathophysiology. Corneal cells also dynamically regulate their extracellular matrix (ECM) with ensuing cell-ECM crosstalk as the matrix serves as a dynamic signaling reservoir providing biophysical and biochemical cues to corneal cells. Here we provide an overview of mechanotransduction signaling pathways then delve into the recent advances in corneal mechanobiology, focusing on the interplay between mechanical forces and responses of the corneal epithelial, stromal, and endothelial cells. We also identify species-specific differences in corneal biomechanics and mechanotransduction to facilitate identification of optimal animal models to study corneal wound healing, disease, and novel therapeutic interventions. Finally, we identify key knowledge gaps and therapeutic opportunities in corneal mechanobiology that are pressing for the research community to address especially pertinent within the domains of limbal stem cell deficiency, keratoconus and Fuchs' endothelial corneal dystrophy. By furthering our understanding corneal mechanobiology, we can contextualize discoveries regarding corneal diseases as well as innovative treatments for them.


Asunto(s)
Distrofia Endotelial de Fuchs , Queratocono , Animales , Mecanotransducción Celular , Células Endoteliales , Córnea/fisiología
10.
Invest Ophthalmol Vis Sci ; 65(1): 11, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38170539

RESUMEN

Purpose: Smoking may influence measured IOP through an effect on corneal biomechanics, but it is unclear whether this factor translates into an increased risk for glaucoma. This study aimed to examine the association of cigarette smoking with corneal biomechanical properties and glaucoma-related traits, and to probe potential causal effects using Mendelian randomization (MR). Methods: Cross-sectional analyses within the UK Biobank (UKB) and Canadian Longitudinal Study on Aging (CLSA) cohorts. Multivariable linear and logistic regression models were used to assess associations of smoking (status, intensity, and duration) with corneal hysteresis (CH), corneal resistance factor, IOP, inner retinal thicknesses, and glaucoma. Two-sample MR analyses were performed. Results: Overall, 68,738 UKB (mean age, 56.7 years; 54.7% women) and 22 845 CLSA (mean age, 62.7 years; 49.1% women) participants were included. Compared with nonsmokers, smokers had a higher CH (UKB, +0.48 mm Hg; CLSA, +0.57 mm Hg; P < 0.001) and corneal resistance factor (UKB, +0.47 mm Hg; CLSA, +0.60 mm Hg; P < 0.001) with evidence of a dose-response effect in both studies. Differential associations with Goldmann-correlated IOP (UKB, +0.25 mm Hg; CLSA, +0.36 mm Hg; P < 0.001) and corneal-compensated IOP (UKB, -0.28 mm Hg; CLSA, -0.32 mm Hg; P ≤ 0.001) were observed. Smoking was not associated with inner retinal thicknesses or glaucoma status in either study. MR provided evidence for a causal effect of smoking on corneal biomechanics, especially higher CH. Conclusions: Cigarette smoking seems to increase corneal biomechanical resistance to deformation, but there was little evidence to support a relationship with glaucoma. This outcome may result in an artefactual association with measured IOP and could account for discordant results with glaucoma in previous epidemiological studies.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fenómenos Biomecánicos , Canadá/epidemiología , Córnea/fisiología , Estudios Transversales , Glaucoma/epidemiología , Glaucoma/etiología , Presión Intraocular , Estudios Longitudinales , Estudios Prospectivos , Fumar/efectos adversos , Tonometría Ocular , Análisis de la Aleatorización Mendeliana
11.
J Glaucoma ; 33(3): 183-188, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37748090

RESUMEN

PRCIS: Use of the Ocular Response Analyzer (ORA) as a screening tonometer in clinical practice yielded reliable measurements in over 80% of eyes screened. Including corneal hysteresis (CH) data in screening may improve the accuracy of glaucoma detection. PURPOSE: To examine measurement reliability when the ORA is used as a screening tonometer, and to compare CH measurements in eyes with and those without glaucomatous changes in the fundus. PATIENTS AND METHODS: 1488 eyes of 747 patients (mean age: 53.5 ± 20.4 y, range: 6-94 y) underwent intraocular pressure (IOP) measurement using ORA as screening. The percentage of eyes with a waveform score ≥6, the recommended threshold indicating reliability, was calculated. Eyes that had waveform score ≥6 and had undergone fundus photography and optical coherence tomography were assessed for the presence or absence of glaucomatous changes in fundus from optical coherence tomography and fundus images, and CH was compared between the 2 groups. RESULTS: Mean ± SD (range) of ORA measurements were: Goldmann-correlated IOP 14.9 ± 4.8 (1.0-63.2) mm Hg, corneal-compensated IOP 16.2 ± 4.7 (3.2-73.6) mm Hg, CH 9.7 ± 1.5 (0.0-20.6) mm Hg, and waveform score 7.3 ± 1.5 (0.1-9.7). Eighty-four percent of eyes had a waveform score ≥6. Among 192 eyes (127 patients, aged 53.5 ± 18.0 y) with waveform score ≥6 and evaluable for glaucomatous changes in the fundus, 53 eyes were determined as positive and 139 eyes as negative. CH was 9.6 ± 1.4 (6.8-13.3) mm Hg in the positive group and 10.2 ± 1.2 (6.9-13.3) mm Hg in the negative group, and was significantly lower in the positive group ( P =0.003). CONCLUSION: When using ORA as a screening tonometer, reliable results were obtained in ~80% of the eyes. CH was lower in the glaucomatous change-positive group compared with the glaucomatous change-negative group, but the ranges overlapped between the 2 groups.


Asunto(s)
Glaucoma , Presión Intraocular , Humanos , Adulto , Persona de Mediana Edad , Anciano , Tonometría Ocular/métodos , Reproducibilidad de los Resultados , Glaucoma/diagnóstico , Córnea/fisiología
12.
Prostaglandins Other Lipid Mediat ; 170: 106802, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38036037

RESUMEN

The transparent cornea is the most densely innervated tissue in the body, primarily by sensory nerves originating from the trigeminal ganglia (TG). Damage to corneal nerves reduces sensitivity and tear secretion and results in dry eye. Consequently, ocular pain, for which no satisfactory therapies exist, arises in many cases. Treatment of injured corneas with pigment epithelium-derived factor (PEDF) combined with docosahexaenoic acid (DHA) stimulates nerve regeneration in models of refractive surgery, which damages nerves. The mechanism involves the synthesis of a stereoisomer of resolvin D6 (R,R-RvD6) formed after incorporating DHA into membrane lipids. Activation of a PEDF receptor (PEDF-R) with phospholipase activity releases DHA to synthesize the new resolvin isomer, which is secreted via tears. Topical treatment of mice corneas with R,R-RvD6 shows higher bioactivity in regenerating nerves and increasing sensitivity compared to PEDF+DHA. It also stimulates a transcriptome in the TG that modulates genes involved in ocular pain. Our studies suggest an important therapeutic role for R,R-RvD6 in regenerating corneal nerves and decreasing pain resulting from dry eye.


Asunto(s)
Córnea , Síndromes de Ojo Seco , Ratones , Animales , Córnea/inervación , Córnea/fisiología , Córnea/cirugía , Ácidos Docosahexaenoicos/farmacología , Ácidos Docosahexaenoicos/uso terapéutico , Regeneración Nerviosa/fisiología , Dolor/tratamiento farmacológico , Síndromes de Ojo Seco/tratamiento farmacológico
13.
J Optom ; 17(2): 100488, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37918060

RESUMEN

PURPOSE: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. METHODS: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. RESULTS: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p<0.05, Spearman). Goldmann-correlated IOP (IOPg) and Corneal-compensated IOP (IOPcc) values were statistically significantly different between the various interferometric patterns (p<0.05). It was also found that an increase in the corneal biomechanical properties measured with ORA was directly correlated with the overall scores obtained when using the OSDI and some of its subclasses. CONCLUSIONS: Tear film interferometric patterns were shown to have some impact on the IOP measured using ORA. The IOP measured with iCare seems to be related to the symptomatology obtained from OSDI. Corneal biomechanical properties were related to the OSDI total score and some of its subclasses. An increase in symptomatology was associated with an increase in the measured biomechanical properties of the cornea.


Asunto(s)
Glaucoma , Presión Intraocular , Humanos , Estudios Transversales , Tonometría Ocular , Córnea/fisiología , Fenómenos Biomecánicos
14.
J Neurotrauma ; 41(7-8): 985-999, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38115600

RESUMEN

Mild traumatic brain injury (mTBI) is often accompanied by neurological and ocular symptoms that involve trigeminal nerve pathways. Laser-induced shock wave (LISW) was applied to the skull of male rats as a model for mTBI, while behavioral and neural recording methods were used to assess trigeminal function. The LISW caused greater eye wiping behavior to ocular instillation of hypertonic saline (Sham = 4.83 ± 0.65 wipes/5 min, LISW = 12.71 ± 1.89 wipes/5 min, p < 0.01) and a marked reduction in the time spent in bright light consistent with enhanced periocular and intraocular hypersensitivity, respectively (Sham = 16.3 ± 5.6 s, LISW = 115.5 ± 27.3 s, p < 0.01). To address the early neural mechanisms of mTBI, single trigeminal brainstem neurons, identified by activation to corneal or dural mechanical stimulation, were recorded in trigeminal subnucleus interpolaris/caudalis (Vi/Vc) and trigeminal subnucleus caudalis/upper cervical cord (Vc/C1) regions. The LISW caused marked sensitization to hypertonic saline and to exposure to bright light in neurons of both regions (p < 0.05). Laser speckle imaging revealed an increase in meningeal arterial blood flow to bright light after LISW (Sham = 4.7 ± 2.0 s, LISW = 469.0 ± 37.9 s, p < 0.001). Local inhibition of synaptic activity at Vi/Vc, but not at Vc/C1, by microinjection of CoCl2, prevented light-evoked increases in meningeal blood flow in LISW-treated rats. By contrast, topical meningeal application of phenylephrine significantly reduced light-evoked responses of Vi/Vc and Vc/C1 neurons. These data suggested that neurons in both regions became sensitized after LISW and were responsive to changes in meningeal blood flow. Neurons at the Vi/Vc transition and at Vc/C1, however, likely serve different roles in mediating the neurovascular and sensory aspects of mTBI.


Asunto(s)
Conmoción Encefálica , Ratas , Masculino , Animales , Ratas Sprague-Dawley , Conmoción Encefálica/metabolismo , Neuronas/metabolismo , Córnea/inervación , Córnea/fisiología , Tronco Encefálico
15.
Biomech Model Mechanobiol ; 23(3): 709-720, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38129672

RESUMEN

We present a patient-specific finite element model of the human cornea that accounts for the presence of the epithelium. The thin anterior layer that protects the cornea from the external actions has a scant relevance from the mechanical point of view, and it has been neglected in most numerical models of the cornea, which assign to the entire cornea the mechanical properties of the stroma. Yet, modern corneal topographers capture the geometry of the epithelium, which can be naturally included into a patient-specific solid model of the cornea, treated as a multi-layer solid. For numerical applications, the presence of a thin layer on the anterior cornea requires a finer discretization and the definition of two constitutive models (including the corresponding properties) for stroma and epithelium. In this study, we want to assess the relevance of the inclusion of the epithelium in the model of the cornea, by analyzing the effects in terms of uncertainties of the mechanical properties, stress distribution across the thickness, and numerical discretization. We conclude that if the epithelium is modeled as stroma, the material properties should be reduced by 10%. While this choice represents a sufficiently good approximation for the simulation of in vivo mechanical tests, it might result into an under-estimation of the postoperative stress in the simulation of refractive surgery.


Asunto(s)
Córnea , Epitelio Corneal , Análisis de Elementos Finitos , Estrés Mecánico , Humanos , Córnea/fisiología , Epitelio Corneal/fisiología , Modelos Biológicos , Fenómenos Biomecánicos , Simulación por Computador , Análisis Numérico Asistido por Computador
16.
Behav Res Methods ; 56(4): 3226-3241, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38114880

RESUMEN

We present a deep learning method for accurately localizing the center of a single corneal reflection (CR) in an eye image. Unlike previous approaches, we use a convolutional neural network (CNN) that was trained solely using synthetic data. Using only synthetic data has the benefit of completely sidestepping the time-consuming process of manual annotation that is required for supervised training on real eye images. To systematically evaluate the accuracy of our method, we first tested it on images with synthetic CRs placed on different backgrounds and embedded in varying levels of noise. Second, we tested the method on two datasets consisting of high-quality videos captured from real eyes. Our method outperformed state-of-the-art algorithmic methods on real eye images with a 3-41.5% reduction in terms of spatial precision across data sets, and performed on par with state-of-the-art on synthetic images in terms of spatial accuracy. We conclude that our method provides a precise method for CR center localization and provides a solution to the data availability problem, which is one of the important common roadblocks in the development of deep learning models for gaze estimation. Due to the superior CR center localization and ease of application, our method has the potential to improve the accuracy and precision of CR-based eye trackers.


Asunto(s)
Córnea , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Córnea/diagnóstico por imagen , Córnea/fisiología , Algoritmos
17.
Comp Med ; 73(5): 373-377, 2023 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-38087405

RESUMEN

Large animal models are essential to research in facial paralysis, face transplant, craniofacial surgery, and ophthalmology. Pigs are a well-studied species with high similarity to human anatomy and physiology for these research areas. However, in contrast to cats and dogs protecting the cornea and eye is difficult in swine due to the inability to use an Elizabethan collar (E-collar) and the complexity of placing and maintaining a temporary tarsorrhaphy for corneal protection due to the strength of the pig levator muscle. This study presents an effective method to provide corneal and eye protection in the domestic swine for at least 50 d. Furthermore, protection of the eye and face is achieved through the innovative use of a modified ophthalmologic face shield. The findings from this study will advance large animal research in these fields, enabling innovation in surgery and tissue engineering in areas of both craniofacial and ophthalmologic research.


Asunto(s)
Córnea , Músculos , Humanos , Porcinos , Gatos , Animales , Perros , Córnea/cirugía , Córnea/anatomía & histología , Córnea/fisiología , Modelos Animales
18.
Exp Eye Res ; 237: 109718, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37952725

RESUMEN

The purpose of this study was to investigate the depth-dependent biomechanical properties of the human corneal stroma under uniaxial tensile loading. Human stroma samples were obtained after the removal of Descemet's membrane in the course of Descemet's membrane endothelial keratoplasty (DMEK) transplantation. Uniaxial tensile tests were performed at three different depths: anterior, central, and posterior on 2 × 6 × 0.15 mm strips taken from the central DMEK graft. The measured force-displacement data were used to calculate stress-strain curves and to derive the tangent modulus. The study showed that mechanical strength decreased significantly with depth. The anterior cornea appeared to be the stiffest, with a stiffness approximately 18% higher than that of the central cornea and approximately 38% higher than that of the posterior layer. Larger variations in mechanical response were observed in the posterior group, probably due to the higher degree of alignment of the collagen fibers in the posterior sections of the cornea. This study contributes to a better understanding of the biomechanical tensile properties of the cornea, which has important implications for the development of new treatment strategies for corneal diseases. Accurate quantification of tensile strength as a function of depth is critical information that is lacking in human corneal biomechanics to develop numerical models and new treatment methods.


Asunto(s)
Córnea , Enfermedades de la Córnea , Humanos , Córnea/fisiología , Sustancia Propia/fisiología , Enfermedades de la Córnea/cirugía , Fenómenos Mecánicos , Resistencia a la Tracción , Lámina Limitante Posterior/cirugía
19.
Invest Ophthalmol Vis Sci ; 64(14): 12, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37938935

RESUMEN

Purpose: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results: Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions: Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.


Asunto(s)
Lentes de Contacto Hidrofílicos , Lentes de Contacto , Síndromes de Ojo Seco , Enfermedades del Aparato Lagrimal , Humanos , Córnea/fisiología , Parpadeo , Lágrimas , Inflamación , Lentes de Contacto Hidrofílicos/efectos adversos , Síndromes de Ojo Seco/etiología
20.
Cont Lens Anterior Eye ; 46(6): 102067, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37863714

RESUMEN

PURPOSE: To investigate the long-term influence of scleral lens (SL) wear on corneal biomechanical properties and intraocular pressure (IOP) in irregular and regular corneas. Secondary goal comprised evaluate the fluid reservoir (FR) thickness overtime and correlate it with the changes in corneal biomechanical parameters and IOP. METHODS: Seventy (70) eyes with irregular corneas (IC Group) and 21 eyes with regular corneas (RC Group) were fitted with 16.4 mm SL and wore the lenses for 12 months. Corrected IOP (IOPcc), Goldmann equivalent IOP (IOPg) and corneal biomechanical parameters (Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF)) were measured with Ocular Response Analyzer. Slit lamp images were analyzed with ImageJ software to assess FR thickness overtime. Measurements were taken at lens dispensing visit prior lens wear (LDV1) and after 60 min of lens wear (LDV2) and at 1, 6 and 12-month follow-up visits. Measurements were done immediately after lens removal. RESULTS: There were no statistically significant differences on IOPcc, IOPg, CRF and CH over the follow-up visits in both groups. Mean IOPcc and IOPg fluctuations overtime were clinically insignificant and below 1 mmHg in both groups. IOPg, CH and CRF were significantly lower on IC Group (p < 0.001), although no statistically significant differences were found between groups for IOPcc. Regarding FR thickness, statistically significant differences were found over the follow-up on both groups, with a mean decrease of 186.29 µm on IC Group and 175.32 µm on RC Group (p < 0.001). Statistically significant moderate to high negative correlations between FR and IOPg, CRF and CH were found only in the RC Group. CONCLUSIONS: Long-term SL wear was not associated to changes in corneal biomechanical parameters neither on IOP as measured after lens removal. Besides IOP measurement without SL removal, more studies are needed to investigate the potential relationship with SL fitting characteristics (namely FR thickness).


Asunto(s)
Oftalmopatías , Presión Intraocular , Humanos , Estudios de Seguimiento , Estudios Prospectivos , Tonometría Ocular , Córnea/fisiología , Fenómenos Biomecánicos , Elasticidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA