Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47.390
Filtrar
1.
Arq Bras Cir Dig ; 37: e1800, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38716920

RESUMEN

BACKGROUND: One of the primary complications associated with large incisions in abdominal surgery is the increased risk of fascial closure rupture and incisional hernia development. The choice of the fascial closure method and closing with minimal tension and trauma is crucial for optimal results, emphasizing the importance of uniform pressure along the suture line to withstand intra-abdominal pressure. AIMS: To evaluate the resistance to pressure and tension of stapled and sutured hand-sewn fascial closure in the abdominal wall. METHODS: Nine abdominal wall flaps from human cadavers and 12 pigs were used for the experimentation. An abdominal defect was induced after the resection of the abdominal wall and the creation of a flap in the cadaveric model and after performing a midline incision in the porcine models. The models were randomized into three groups. Group 1 was treated with a one-layer hand-sewn small bite suture, Group 2 was treated with a two-layer hand-sewn small bite suture, and Group 3 was treated with a two-layer stapled closure. Tension measurements were assessed in cadaveric models, and intra-abdominal pressure was measured in porcine models. RESULTS: In the human cadaveric model, the median threshold for fascial rupture was 300N (300-350) in Group 1, 400N (350-500) in Group 2, and 350N (300-380) in Group 3. Statistical comparisons revealed non-significant differences between Group 1 and Group 2 (p=0.072, p>0.05), Group 1 and Group 3 (p=0.346, p>0.05), and Group 2 and Group 3 (p=0.184, p>0.05). For porcine subjects, Group 1 showed a median pressure of 80 mmHg (85-105), Group 2 had a median of 92.5 mmHg (65-95), and Group 3 had a median of 102.5 mmHg (80-135). Statistical comparisons indicated non-significant differences between Group 1 and Group 2 (p=0.243, p>0.05), Group 1 and Group 3 (p=0.468, p>0.05), and Group 2 and Group 3 (p=0.083, p>0.05). CONCLUSIONS: Stapled and conventional suturing resist similar pressure and tension thresholds.


Asunto(s)
Pared Abdominal , Cadáver , Técnicas de Sutura , Humanos , Animales , Porcinos , Pared Abdominal/cirugía , Técnicas de Cierre de Herida Abdominal , Grapado Quirúrgico , Modelos Animales , Fasciotomía/métodos , Femenino , Masculino
2.
Jt Dis Relat Surg ; 35(2): 305-314, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727109

RESUMEN

OBJECTIVES: This study aimed to explore the use of Gerdy's tubercle (GT) as an innovative and dependable anatomical landmark for the proximal tibial cut in total knee arthroplasty (TKA) in cases with extensive knee degeneration. MATERIALS AND METHODS: One hundred dry tibia bones and 10 formalin-fixed cadaveric knee specimens of both sexes were examined. A Zimmer NexGen tibial cutting guide and a Mitutoyo digital caliper were utilized to align the guide with the tibia's mechanical axis. The procedure was replicated on cadaver knees using a standardized medial parapatellar arthrotomy approach. Measurements included the distance from GT superior border to the resection line and the length of the tibia. A radiological study involving magnetic resonance imaging examinations of 48 patients, which were evaluated focusing on the upper border of GT and the least degenerated segment of the posterolateral part of the lateral tibial condyle, was conducted. RESULTS: Anatomical measurements of GT and proximal tibial areas in 110 specimens showed slight but consistent variations with cadaver measurements. Magnetic resonance imaging analysis of 48 patients revealed notable sex differences in the distance between the superior border of GT and the tibia's posterolateral surface. There was also a significant negative correlation between the distance from GT to the posterolateral corner and cartilage thickness. CONCLUSION: Proper alignment in TKA is crucial for success, but identifying an extra-articular landmark for horizontal tibial resection remains challenging, particularly in severely arthritic knees. This study introduces GT as a novel anatomical landmark for TKA, offering a more reliable reference for achieving desired joint levels in knees with significant degenerative changes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cadáver , Imagen por Resonancia Magnética , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Tibia/cirugía , Tibia/anatomía & histología , Tibia/diagnóstico por imagen , Anciano , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/patología , Puntos Anatómicos de Referencia , Anciano de 80 o más Años
3.
J Phys Ther Educ ; 38(2): 107-115, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758175

RESUMEN

INTRODUCTION: Despite a long history of using human donor dissection (HDD) for physical therapy (PT) anatomy education, there are no PT guidelines that require HDD. The purpose of this quantitative causal-comparative study was to determine if Doctor of Physical Therapy students who used HDD had different grades both within anatomy and within courses that require retention and application of anatomical knowledge (kinesiology and a foundational musculoskeletal course) compared with those who used virtual 3-dimensional anatomical software (VAS). REVIEW OF LITERATURE: Numerous factors affect the decision to use HDD within PT anatomy, and few PT studies have compared the effectiveness of VAS to HDD. SUBJECTS: All students who took anatomy in an entry-level PT program from 2018 to 2021 (232 total students, 115 who used HDD in 2018-2019 and 117 who used VAS in 2020-2021). METHODS: Mann-Whitney tests were used to compare anatomy grades (course, written examination, and practical examination) and future grades in kinesiology and a foundational musculoskeletal course for students who used HDD or VAS. RESULTS: Physical therapy students who used VAS had statistically significant higher anatomy course grades (VAS 93.81% ± 4.99% to HDD 92.20% ± 4.53%) and higher practical examination grades (VAS 97.43% ± 2.91% to HDD 93.55% ± 4.39%) compared with those who used HDD. However, there were no significant differences between groups on written anatomy examinations (VAS 89.42% ± 7.21% to HDD 90.40% ± 4.94%), kinesiology grades (VAS 91.86% ± 4.52% to HDD 92.80% ± 4.27%), or foundational musculoskeletal grades (VAS 89.50% ± 3.89% to HDD 89.77% ± 3.83%). DISCUSSION AND CONCLUSION: The causal-comparative study design prevents concluding that PT student grade differences were due exclusively to either anatomy laboratory method. It does provide preliminary evidence that the PT anatomy laboratory method did not practically affect anatomy performance or long-term application of anatomy knowledge in future coursework.


Asunto(s)
Anatomía , Disección , Humanos , Anatomía/educación , Evaluación Educacional , Cadáver , Masculino , Especialidad de Fisioterapia/educación , Femenino
4.
Sci Rep ; 14(1): 10881, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740762

RESUMEN

This cadaveric study aimed to evaluate the safety and usability of a novel robotic system for posterior cervical pedicle screw fixation. Three human cadaveric specimens and C2-T3 were included. Freshly frozen human cadaver specimens were prepared and subjected to robot-assisted posterior cervical pedicle screw fixation using the robotic system. The accuracy of screw placement, breach rate, and critical structure violations were evaluated. The results were statistically compared with those of previous studies that used different robotic systems for cervical pedicle screw fixation. The robotic system demonstrated a high accuracy rate in screw placement. A significant number of screws were placed within predetermined safe zones. The total entry offset was 1.08 ± 0.83 mm, the target offset was 1.86 ± 0.50 mm, and the angle offset was 2.14 ± 0.77°. Accuracy rates comparable with those of previous studies using different robotic systems were achieved. The system was also feasible, allowing precise navigation and real-time feedback during the procedure. This cadaveric study validated the safety and usability of the novel robotic system for posterior cervical pedicle screw fixation. The system exhibited high precision in screw placement, and the results support the extension of the indications for robot-assisted pedicle screw fixation from the lumbar spine to the cervical spine.


Asunto(s)
Cadáver , Vértebras Cervicales , Estudios de Factibilidad , Tornillos Pediculares , Procedimientos Quirúrgicos Robotizados , Humanos , Vértebras Cervicales/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Masculino , Femenino
5.
Sci Rep ; 14(1): 10875, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740845

RESUMEN

Three-dimensional information is essential for a proper understanding of the healing potential of the menisci and their overall role in the knee joint. However, to date, the study of meniscal vascularity has relied primarily on two-dimensional imaging techniques. Here we present a method to elucidate the intricate 3D meniscal vascular network, revealing its spatial arrangement, connectivity and density. A polymerizing contrast agent was injected into the femoral artery of human cadaver legs, and the meniscal microvasculature was examined using micro-computed tomography at different levels of detail and resolution. The 3D vascular network was quantitatively assessed in a zone-base analysis using parameters such as diameter, length, tortuosity, and branching patterns. The results of this study revealed distinct vascular patterns within the meniscus, with the highest vascular volume found in the outer perimeniscal zone. Variations in vascular parameters were found between the different circumferential and radial meniscal zones. Moreover, through state-of-the-art 3D visualization using micro-CT, this study highlighted the importance of spatial resolution in accurately characterizing the vascular network. These findings, both from this study and from future research using this technique, improve our understanding of microvascular distribution, which may lead to improved therapeutic strategies.


Asunto(s)
Imagenología Tridimensional , Microvasos , Microtomografía por Rayos X , Humanos , Imagenología Tridimensional/métodos , Microvasos/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/irrigación sanguínea , Menisco/diagnóstico por imagen , Masculino , Cadáver , Femenino
6.
Physiol Res ; 73(2): 217-225, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38710053

RESUMEN

An analytical method for studying DNA degradation by electrophoresis after cell lysis and visualization of DNA fragments with fluorescent dye, comet assay, was used to evaluate the viability of the endothelial layer of human arterial grafts with the aim of identifying the procedure that will least damage the tissue before cryopreservation. Four groups of samples were studied: cryopreserved arterial grafts that were thawed in two different ways, slowly lasting 2 hours or rapidly for approx. 7 minutes. Arterial grafts that were collected as part of multiorgan procurement with minimal warm ischemia time. Cadaveric grafts were taken as part of the autopsy, so they have a more extended period of warm ischemia. The HeadDNA (%) parameter and others commonly used parameters like TailDNA (%). TailMoment, TailLength, OliveMoment, TailMoment to characterize the comet were used to assess viability in this study. The ratio of non-decayed to decayed nuclei was determined from the values found. This ratio for cadaveric grafts was 0.63, for slowly thawed cryopreserved grafts 2.9, for rapidly thawed cryopreserved grafts 1.9, and for multi-organ procurement grafts 0.68. The results of the study confirmed the assumption that the allografts obtained from cadaveric donors are the least suitable. On the other hand, grafts obtained from multiorgan donors are better in terms of viability monitored by comet assay. Keywords: Arterial grafts, Cryopreservation, Cadaveric, Multiorgan procurement, Viability, Comet assay.


Asunto(s)
Ensayo Cometa , Criopreservación , Humanos , Cadáver , Arterias/trasplante , Supervivencia de Injerto/fisiología
7.
Eur Radiol Exp ; 8(1): 56, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38714623

RESUMEN

OBJECTIVE: Guyon's canal syndrome is caused by compression of the ulnar nerve at the wrist, occasionally requiring decompression surgery. In recent times, minimally invasive approaches have gained popularity. The aim of this study was to assess the efficacy and safety of ultrasound-guided thread release for transecting the palmar ligament in Guyon's canal without harming surrounding structures, in a cadaveric specimen model. METHODS: After ethical approval, thirteen ultrasound-guided thread releases of Guyon's canal were performed on the wrists of softly embalmed anatomic specimens. Cadavers showing injuries or prior operations at the hand were excluded. Subsequently, the specimens were dissected, and the outcome of the interventions and potential damage to adjacent anatomical structures as well as ultrasound visibility were evaluated with a score from one to three. RESULTS: Out of 13 interventions, a complete transection was achieved in ten cases (76.9%), and a partial transection was documented in three cases (23.1%). Irrelevant lesions on the flexor tendons were observed in two cases (15.4%), and an arterial branch was damaged in one (7.7%). Ultrasound visibility varied among specimens, but essential structures were delineated in all cases. CONCLUSION: Ultrasound-guided thread release of Guyon's canal has shown promising first results in anatomic specimens. However, further studies are required to ensure the safety of the procedure. RELEVANCE STATEMENT: Our study showed that minimally invasive ultrasound-guided thread release of Guyon's canal is a feasible approach in the anatomical model. The results may provide a basis for further research and refinement of this technique. KEY POINTS: • In Guyon's canal syndrome, the ulnar nerve is compressed at the wrist, often requiring surgical release. • We adapted and tested a minimally invasive ultrasound-guided thread release technique in anatomic specimens. • The technique was effective; however, in one specimen, a small anatomic branch was damaged.


Asunto(s)
Cadáver , Procedimientos Quirúrgicos Mínimamente Invasivos , Ultrasonografía Intervencional , Humanos , Ultrasonografía Intervencional/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Masculino , Femenino , Síndromes de Compresión del Nervio Cubital/cirugía , Síndromes de Compresión del Nervio Cubital/diagnóstico por imagen , Anciano , Descompresión Quirúrgica/métodos
8.
J Orthop Traumatol ; 25(1): 27, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769283

RESUMEN

BACKGROUND: Tibial plateau fractures involving posteromedial (PM) and posterolateral (PL) columns are complex injuries that require an appropriate approach. The management of the PL column in these cases can be controversial, and limitations using deep posteromedial interval approaches have been referenced. In this paper, a modification of the Lobenhoffer approach, designed to optimize the access to the PL column, is described in detail. The aim of this study was to assess the feasibility of this approach in a cadaveric anatomical study. MATERIALS AND METHODS: In total, five fresh-frozen cadaveric specimens were used for detailed anatomical study surrounding the approach. Relationships with cutaneous and deep neurovascular structures were evaluated. The exposure area of the PL and PM columns using this approach was assessed. RESULTS: The cadaveric study showed safe and adequate exposure. Oblique skin and fascia incision just medial to the posterior midline was safe to protect the medial sural cutaneous nerve and the small saphenous vein. Elevation of the popliteus and tibialis posterior muscles offered safe protection of the anterior tibial artery and popliteal neurovascular bundle during retractor placement. Adequate full proximal exposure of the PM and PL columns, including the posterolateral lateral (PLL) and posterolateral central (PLC) segments, was obtained in all specimens. CONCLUSIONS: The Modified Oblique Lobenhoffer (MOL) approach can be a feasible option to access PL and PM columns in tibial plateau fractures. LEVEL OF EVIDENCE: IV.


Asunto(s)
Cadáver , Fijación Interna de Fracturas , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fijación Interna de Fracturas/métodos , Estudios de Factibilidad , Fracturas de la Meseta Tibial
9.
Sci Rep ; 14(1): 10760, 2024 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729983

RESUMEN

Measurement of auricle parameters for planning and post-operative evaluation presents substantial challenges due to the complex 3D structure of the human auricle. Traditional measurement methods rely on manual techniques, resulting in limited precision. This study introduces a novel automated surface-based three-dimensional measurement method for quantifying human auricle parameters. The method was applied to virtual auricles reconstructed from Computed Tomography (CT) scans of a cadaver head and subsequent measurement of important clinically relevant aesthetical auricular parameters (length, width, protrusion, position, auriculocephalic angle, and inclination angle). Reference measurements were done manually (using a caliper and using a 3D landmarking method) and measurement precision was compared to the automated method. The CT scans were performed using both a contemporary high-end and a low-end CT scanner. Scans were conducted at a standard scanning dose, and at half the dose. The automatic method demonstrated significantly higher precision in measuring auricle parameters compared to manual methods. Compared to traditional manual measurements, precision improved for auricle length (9×), width (5×), protrusion (5×), Auriculocephalic Angle (5-54×) and posteroanterior position (23×). Concerning parameters without comparison with a manual method, the precision level of supero-inferior position was 0.489 mm; and the precisions of the inclination angle measurements were 1.365 mm and 0.237 mm for the two automated methods investigated. Improved precision of measuring auricle parameters was associated with using the high-end scanner. A higher dose was only associated with a higher precision for the left auricle length. The findings of this study emphasize the advantage of automated surface-based auricle measurements, showcasing improved precision compared to traditional methods. This novel algorithm has the potential to enhance auricle reconstruction and other applications in plastic surgery, offering a promising avenue for future research and clinical application.


Asunto(s)
Algoritmos , Pabellón Auricular , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Pabellón Auricular/diagnóstico por imagen , Pabellón Auricular/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Imagenología Tridimensional/métodos , Cadáver , Masculino
10.
Invest Ophthalmol Vis Sci ; 65(5): 13, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713484

RESUMEN

Purpose: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. Methods: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. Results: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. Conclusions: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.


Asunto(s)
Cadáver , Gonioscopía , Presión Intraocular , Iris , Terapia por Láser , Trabeculectomía , Humanos , Presión Intraocular/fisiología , Terapia por Láser/métodos , Iris/cirugía , Trabeculectomía/métodos , Tonometría Ocular , Anciano , Iridectomía/métodos , Femenino , Masculino , Anciano de 80 o más Años
11.
BMC Vet Res ; 20(1): 194, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734622

RESUMEN

In the left axilla of a formalin-embalmed adult female cross-breed dog, an unusual course of the axillary artery in relation to the brachial plexus was noted. A part of the axillary artery after the origin of the subscapular artery coursed through the loop formed by the contributions of the caudal pectoral and lateral thoracic nerves and then between the median and ulnar nerves. Thus, the common trunk for the latter two nerves was missing. Instead, in the proximal brachium, they communicated with each other in both directions. A communicating branch between the cranial and caudal pectoral nerves forming a nerve loop, ansa pectoralis lacked the axillary artery and was instead traversed by the subscapular artery. This is a variation in the relationship between the axillary artery and brachial plexus in the domestic dog and has not been reported in the literature yet. The axillary artery entrapped by the contributions of the caudal and lateral thoracic nerves may be considered as a risk factor for the neuroarterial compressions with non-specific signs and should be taken into account both in surgery and imaging.


Asunto(s)
Arteria Axilar , Plexo Braquial , Cadáver , Animales , Perros , Arteria Axilar/anatomía & histología , Plexo Braquial/anatomía & histología , Femenino , Terminología como Asunto
12.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241257169, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38769768

RESUMEN

Background: The purpose of this study was to investigate the effect of 3D-printed technology to repair glenoid bone defect on shoulder joint stability. Methods: The shoulder joints of 25 male cadavers were tested. The 3D-printed glenoid pad was designed and fabricated. The specimens were divided into 5 groups. Group A: no bone defect and the structure of the glenoid labrum and joint capsule was intact; Group B: Anterior inferior bone defect of the shoulder glenoid; Group C: a pad with a width of 2 mm was installed; Group D: a pad with a width of 4 mm was installed; Group E: a pad with a width of 6 mm was installed. This study measured the distance the humeral head moved forward at the time of glenohumeral dislocation and the maximum load required to dislocate the shoulder. Results: The shoulder joint stability and humerus displacement was significantly lower in groups B and C compared with group A (p < .05). Compared with group A, the stability of the shoulder joint of group D was significantly improved (p < .05). However, there was no significant difference in humerus displacement between groups D and A (p > .05). In addition, compared with group A, shoulder joint stability was significantly increased and humerus displacement was significantly decreased in group E (p < .05). Conclusion: The 3D-printed technology can be used to make the shoulder glenoid pad to perfectly restore the geometric shape of the shoulder glenoid articular surface. Moreover, the 3D-printed pad is 2 mm larger than the normal glenoid width to restore the initial stability of the shoulder joint.


Asunto(s)
Aleaciones , Cadáver , Impresión Tridimensional , Articulación del Hombro , Titanio , Humanos , Masculino , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/fisiopatología , Cavidad Glenoidea/cirugía , Diseño de Prótesis
13.
BMC Med Educ ; 24(1): 535, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745152

RESUMEN

BACKGROUND: Musculoskeletal (MSK) complaints often present initially to primary care physicians; however, physicians may lack appropriate instruction in MSK procedures. Diagnostic and therapeutic injections are useful orthopedic tools, but inaccuracy leads to unnecessary costs and inadequate treatment. The authors hypothesized that trainees afforded the opportunity to practice on a cadaver versus those receiving visual-aided instruction on subacromial injections (SAI) will demonstrate differences in accuracy and technique. METHODS: During Spring of the year 2022, 24 Internal Medicine and Family Medicine residents were randomly divided into control and intervention groups to participate in this interventional randomized cadaveric study. Each group received SAI instruction via lecture and video; the intervention group practiced on cadavers under mentored guidance. Subjects underwent a simulated patient encounter culminating in injection of latex dye into a cadaveric shoulder. Participants were evaluated based on a technique rubric, and accuracy of injections was assessed via cadaver dissection. RESULTS: Twenty-three of twenty-four participants had performed at least one MSK injection in practice, while only 2 (8.3%) of participants had performed more than 10 SAIs. There was no difference in technique between control 18.4 ± 3.65 and intervention 19.2 ± 2.33 (p = 0.54). Dissections revealed 3 (25.0%) of control versus 8 (66.7%) of intervention injections were within the subacromial space. Chi-Square Analysis revealed that the intervention affected the number of injections that were within the subacromial space, in the tissues bordering the subacromial space, and completely outside the subacromial space and bordering tissues (p = 0.03). The intervention group had higher self-confidence in their injection as opposed to controls (p = 0.04). Previous SAI experience did not affect accuracy (p = 0.76). CONCLUSIONS: Although primary care physicians and surgeons develop experience with MSK procedures in practice, this study demonstrates a role for early integrated instruction and simulation to improve accuracy and confidence. The goal of improving accuracy in MSK procedures amongst all primary care physicians may decrease costs and avoid unnecessary referrals, diagnostic tests, and earlier than desired surgical intervention.


Asunto(s)
Cadáver , Competencia Clínica , Internado y Residencia , Entrenamiento Simulado , Humanos , Inyecciones Intraarticulares , Medicina Interna/educación , Masculino , Femenino , Medicina Familiar y Comunitaria/educación
14.
Artículo en Inglés | MEDLINE | ID: mdl-38758688

RESUMEN

BACKGROUND: Arthroscopy has become increasingly common for diagnosis and treatment of ankle joint pathology. The four most common portals used for ankle arthroscopy are the anteromedial, anterolateral, posteromedial, and posterolateral. Anatomy of neurovascular structures along the ankle can significantly vary. METHODS: The distance of neurovascular structures was compared with anatomical landmarks of ankle arthroscopic portals to verify safe zones for scope insertion. Twenty-six fresh frozen cadavers were used, with dissection of standard anatomical landmarks and neurovascular structures. Portals were made and verified with a 2.7-mm arthroscope. RESULTS: Significant differences were found in mean distances between anatomical landmarks except for the peroneus tertius tendon to the intermediate dorsal cutaneous nerve (P = .181; all others, P < .0001). In quantifying a scope space, the anteromedial and anterolateral portals had the largest margin of error at 0.82 cm and 1.04 cm, respectively. The saphenous nerve and vein were an average of 1.39 cm and 1.23 cm, respectively, from the anteromedial portal. The peroneus tertius tendon was an average of 0.23 cm from the intermediate dorsal cutaneous nerve. The tibialis anterior tendon was an average of 1.10 cm lateral to the medial gutter; the peroneus tertius tendon, 1.31 cm medial to the lateral gutter; and the Achilles tendon, 0.94 and 0.73 cm from the medial and lateral gutters, respectively. CONCLUSIONS: Among common ankle arthroscopic approaches, the anterolateral portal features the highest anatomic variability. These data support the standard protocol of beginning with the anteromedial portal to facilitate visualization of lateral-sided anatomy before anterolateral portal placement.


Asunto(s)
Articulación del Tobillo , Artroscopía , Cadáver , Humanos , Artroscopía/métodos , Articulación del Tobillo/anatomía & histología , Articulación del Tobillo/cirugía , Masculino , Femenino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años
15.
Prague Med Rep ; 125(2): 163-171, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38761050

RESUMEN

Anatomical variations of the forearm flexor muscles are occasionally encountered. Though usually observed incidentally during autopsies or imaging studies, they may at times cause concern due to associated clinical symptoms. This report presents a case of unilateral accessory flexor carpi ulnaris (AFCU) muscle observed in a human male cadaver aged 78 years. During routine cadaveric dissection, an anomalous AFCU muscle was observed in the left forearm of a human male cadaver aged 78 years. Standard institutional guidelines pertaining to the use of human cadaver for teaching and research were followed. A thorough literature review about the flexor carpi ulnaris (FCU) through the PubMed, Embase and Google scholar databases was undertaken, using the keywords - accessory flexor carpi ulnaris muscle, aberrant flexor carpi ulnaris muscle and anatomical variation of flexor carpi ulnaris muscle. Relevant gross anatomical findings were recorded and photographed. AFCU was identified on the medial aspect of the distal third of the left forearm. The AFCU was found originating from the ante-brachial fascia and the fascia covering the FCU on the left forearm, forming a small separate belly deep to the main muscle. It terminated as a thin tendon running alongside the hypothenar muscles and attached distally to the base of the proximal phalanx of the little finger. The AFCU was found to be innervated by a branch of the ulnar nerve. Awareness about the rare AFCU muscle is clinically important as a possible cause of ulnar nerve compression but also as a possible graft in reconstruction surgeries.


Asunto(s)
Cadáver , Antebrazo , Músculo Esquelético , Humanos , Masculino , Anciano , Músculo Esquelético/anomalías , Músculo Esquelético/anatomía & histología , Antebrazo/anomalías , Antebrazo/anatomía & histología
16.
JMIR Res Protoc ; 13: e57329, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38669065

RESUMEN

BACKGROUND: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/57329.


Asunto(s)
Extremidad Inferior , Piel , Tibia , Humanos , Muñones de Amputación/diagnóstico por imagen , Muñones de Amputación/fisiopatología , Miembros Artificiales , Fenómenos Biomecánicos/fisiología , Cadáver , Extremidad Inferior/diagnóstico por imagen , Extremidad Inferior/cirugía , Extremidad Inferior/fisiología , Movimiento/fisiología , Piel/diagnóstico por imagen , Tibia/diagnóstico por imagen , Tibia/cirugía
17.
Injury ; 55(6): 111519, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38584077

RESUMEN

BACKGROUND: In this study, we investigated the area that can be addressed with an approach in which the skin incision is made directly above the dorsal column with Thiel cadaveric specimens. METHODS: Six Thiel cadaveric specimens were prepared. A skin incision was made directly above the dorsal column. The accessible proximal end from the proximal part of the greater sciatic notch to the gluteal ridge and the accessible distal end of the ischium were marked with a flat chisel. A molded 8-hole reconstruction plate was placed from the base of the ischium toward the gluteal ridge and fixed with 3 screws proximally and 2 screws distally. The length of the skin incision and the distance from each reference point on the bone to the reachable markings were assessed after the muscles were removed. RESULTS: Mean skin incision length was 9.3 ± 0.7 (range, 8.0-10.0) cm. In 3 of 6 cases, proximal screws were inserted through different spaces between muscle fibers. In all cases, we were able to reach at least the greater sciatic notch, the gluteal ridge at the level of superior border of the acetabulum, and the base of the ischial tuberosity. In all cases, an 8-hole plate could be placed from the gluteal ridge to the base of the ischium. There were no superior gluteal artery or sciatic nerve injuries in any of the cases. CONCLUSION: We anatomically investigated the area that can be addressed with an approach in which the skin incision was made directly above the dorsal column. In all cases, we were able to access the areas needed to reduce the fracture and place the plates necessary to stabilize the fracture through a 9.3 ± 0.7 cm skin incision. This approach can be a useful minimally invasive posterior approach for acetabular fractures.


Asunto(s)
Acetábulo , Placas Óseas , Cadáver , Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Acetábulo/lesiones , Acetábulo/cirugía , Acetábulo/anatomía & histología , Nalgas/cirugía , Nalgas/irrigación sanguínea , Nalgas/lesiones , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Tornillos Óseos , Masculino , Femenino , Isquion/cirugía , Isquion/anatomía & histología , Anciano
18.
Injury ; 55(6): 111532, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38614015

RESUMEN

BACKGROUND: Fixation of sustentaculum tali fractures is important to maintain the biomechanical function of the subtalar joint. A common method of fixation is securing the sustentacular fragment by way of a laterally based locking plate (LP). A medial approach with a single screw (MS) has been proposed as an alternative method of fixation. METHODS: Five pairs of formalin-preserved cadaveric ankles with the subtalar joint and interosseous ligaments intact ("osseous cadavers") and four pairs of fresh-frozen cadaveric ankles with soft-tissue preserved dissected from mid-tibia down ("soft tissue cadavers") were used in the study. The left ankle was randomly assigned to one of the two fixation methods (LP or MS), while the right ankle was the opposite. These same steps for fixation were repeated for six synthetic ankle models. All models were loaded with a body mass of 80 kg. Statistical differences between LP and MS stiffness were determined using a paired t-test in cadavers and un-paired t-tests in synthetic ankles. RESULTS: For osseous cadaveric ankles, LP demonstrated a mean stiffness of 232.95(SD: 59.96) N/mm, while MS was 239.72(SD:131.09) N/mm (p = 0.9293). For soft tissue cadaveric ankles, LP mean stiffness was 133.58(SD:37.84) N/mm, while MS was 134.88(SD:20.75) N/mm (p = 0.9578). For synthetic ankles, LP mean stiffness was 220.40(SD:81.93) N/mm, while MS was 261.50(SD:100.21) N/mm (p = 0.6116). CONCLUSIONS: Across all three models, there was no significant difference between LP and MS methods. Retrospective observational studies are recommended to assess patient outcomes from each of the methods.


Asunto(s)
Placas Óseas , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Articulación Talocalcánea/cirugía , Articulación Talocalcánea/fisiopatología , Astrágalo/cirugía , Astrágalo/lesiones , Fracturas de Tobillo/cirugía , Fracturas de Tobillo/fisiopatología , Masculino
19.
Injury ; 55(6): 111540, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38622039

RESUMEN

OBJECTIVES: In far-distal extra-articular tibia fracture "extreme" nailing, debate surrounds the relative biomechanical performance of plating the fibula compared with extra distal interlocks. This study aimed to evaluate several constructs for extreme nailing including one interlock (one medial-lateral interlock), one interlock + plate (one medial-lateral interlock with lateral fibula compression plating), and two interlocks (one medial-lateral interlock and one anterior-posterior interlock). METHODS: Fifteen pairs of fresh cadaver legs were instrumented with a tibial nail to the physeal scar. A 1 cm segment of bone was resected from the distal tibia 3.5 cm from the joint and an oblique osteotomy was made in the distal fibula. We loaded specimens with three different distal fixation constructs (one interlock, one interlock + plate, and two interlocks) through 10,000 cycles form 100N-700 N of axial loading. Load to failure (Newtons), angulation and displacement were also measured. RESULTS: Mean load to failure was 2092 N (one interlock), 1917 N (one interlock + plate), and 2545 N (two interlocks). Linear mixed effects modeling demonstrated that two interlocks had a load to failure 578 N higher than one interlock alone (95 % CI, 74N-1082 N; P = 0.02), but demonstrated no significant difference between one interlock and one interlock + plate. No statistically significant difference in rates or timing of displacement >2 mm or angulation >10° were demonstrated. CONCLUSIONS: When nailing far-distal extra-articular tibia and fibula fractures, adding a second interlock provides more stability than adding a fibular plate. Distal fibula plating may have minimal biomechanical effect in extreme nailing.


Asunto(s)
Clavos Ortopédicos , Placas Óseas , Cadáver , Peroné , Fijación Intramedular de Fracturas , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/fisiopatología , Fenómenos Biomecánicos , Peroné/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Masculino , Femenino , Soporte de Peso/fisiología , Anciano , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Anciano de 80 o más Años
20.
Medicina (Kaunas) ; 60(4)2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38674181

RESUMEN

Background and Objectives: This study aims to identify the precise anatomical location and therapeutic mechanisms of the KI1 acupoint (Yongquan) in relation to foot muscles and nerves, known for treating neurological disorders and pain. Materials and Methods: Dissection of six cadavers at Chungnam National University College of Medicine examined KI1's relation to the foot's four-layer structure. Results: The KI1 acupoint was located in the superficial and deep layers of the plantar foot, adjacent to significant nerves like the medial and lateral plantar nerves. Differences in the acupoint's exact location between genders were noted, reflecting variances in foot morphology. KI1 acupuncture was found to stimulate the muscle spindles and nerve fibers essential for balance and bipedal locomotion. This stimulation may enhance sensory feedback, potentially improving cognitive functions and balance control. Conclusions: This anatomical insight into KI1 acupuncture underpins its potential in neurological therapies and pain management.


Asunto(s)
Puntos de Acupuntura , Pie , Humanos , Masculino , Femenino , Pie/fisiología , Pie/inervación , Pie/anatomía & histología , Cadáver , Terapia por Acupuntura/métodos , Nervio Tibial/fisiología , Nervio Tibial/anatomía & histología , Anciano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA