Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.244
Filtrar
1.
BMC Pediatr ; 24(1): 325, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734598

RESUMEN

BACKGROUND: Cerebrospinal fluid (CSF) shunts allow children with hydrocephalus to survive and avoid brain injury (J Neurosurg 107:345-57, 2007; Childs Nerv Syst 12:192-9, 1996). The Hydrocephalus Clinical Research Network implemented non-randomized quality improvement protocols that were shown to decrease infection rates compared to pre-operative prophylactic intravenous antibiotics alone (standard care): initially with intrathecal (IT) antibiotics between 2007-2009 (J Neurosurg Pediatr 8:22-9, 2011), followed by antibiotic impregnated catheters (AIC) in 2012-2013 (J Neurosurg Pediatr 17:391-6, 2016). No large scale studies have compared infection prevention between the techniques in children. Our objectives were to compare the risk of infection following the use of IT antibiotics, AIC, and standard care during low-risk CSF shunt surgery (i.e., initial CSF shunt placement and revisions) in children. METHODS: A retrospective observational cohort study at 6 tertiary care children's hospitals was conducted using Pediatric Health Information System + (PHIS +) data augmented with manual chart review. The study population included children ≤ 18 years who underwent initial shunt placement between 01/2007 and 12/2012. Infection and subsequent CSF shunt surgery data were collected through 12/2015. Propensity score adjustment for regression analysis was developed based on site, procedure type, and year; surgeon was treated as a random effect. RESULTS: A total of 1723 children underwent initial shunt placement between 2007-2012, with 1371 subsequent shunt revisions and 138 shunt infections. Propensity adjusted regression demonstrated no statistically significant difference in odds of shunt infection between IT antibiotics (OR 1.22, 95% CI 0.82-1.81, p = 0.3) and AICs (OR 0.91, 95% CI 0.56-1.49, p = 0.7) compared to standard care. CONCLUSION: In a large, observational multicenter cohort, IT antibiotics and AICs do not confer a statistically significant risk reduction compared to standard care for pediatric patients undergoing low-risk (i.e., initial or revision) shunt surgeries.


Asunto(s)
Antibacterianos , Profilaxis Antibiótica , Derivaciones del Líquido Cefalorraquídeo , Humanos , Derivaciones del Líquido Cefalorraquídeo/efectos adversos , Antibacterianos/administración & dosificación , Estudios Retrospectivos , Niño , Masculino , Preescolar , Femenino , Lactante , Profilaxis Antibiótica/métodos , Adolescente , Inyecciones Espinales , Hidrocefalia/cirugía , Catéteres de Permanencia/efectos adversos , Infección de la Herida Quirúrgica/prevención & control , Infecciones Relacionadas con Catéteres/prevención & control , Catéteres
2.
Braz J Cardiovasc Surg ; 39(2): e20230354, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748605

RESUMEN

Postoperative pain after cardiac surgery plays an important role in the patient's recovery process. In particular, pain at the chest tube site can negatively affect the comfort and recovery of these patients. Effective pain control minimizes the risk of many complications. Oral and intravenous analgesics, epidural anesthesia, paravertebral block, and intercostal nerve blockade are used in chest tube pain control. We routinely use the surgical cryoablation method in the presence of atrial fibrillation in the preoperative period of cardiac surgery in our clinic. Here we aimed to describe our method of using the cryoablation catheter for intercostal nerve blockade.


Asunto(s)
Fibrilación Atrial , Tubos Torácicos , Criocirugía , Dolor Postoperatorio , Humanos , Fibrilación Atrial/cirugía , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/etiología , Criocirugía/métodos , Criocirugía/instrumentación , Bloqueo Nervioso/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Nervios Intercostales , Resultado del Tratamiento , Catéteres
3.
Anesthesiol Clin ; 42(2): 317-328, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38705679

RESUMEN

Continuous peripheral nerve block catheters are simple in concept: percutaneously inserting a catheter adjacent to a peripheral nerve. This procedure is followed by local anesthetic infusion via the catheter that can be titrated to effect for extended anesthesia or analgesia in the perioperative period. The reported benefits of peripheral nerve catheters used in the surgical population include improved pain scores, decreased narcotic use, decreased nausea/vomiting, decreased pruritus, decreased sedation, improved sleep, and improved patient satisfaction.


Asunto(s)
Catéteres , Bloqueo Nervioso , Humanos , Anestésicos Locales/administración & dosificación , Cateterismo/métodos , Bloqueo Nervioso/métodos , Nervios Periféricos
4.
A A Pract ; 18(5): e01785, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727098

RESUMEN

This case series describes the safety and effectiveness of superficial parasternal intercostal plane catheters for poststernotomy pain control in 4 patients who underwent multivessel coronary artery bypass grafting. Patients had reduced sternal pain and opioid consumption while the catheters ran continuously for 72 hours without complications. Our experience suggests the effectiveness of parasternal blocks can be safely prolonged with catheters, and they can be a useful addition to pain management strategies for this patient population.


Asunto(s)
Bloqueo Nervioso , Dolor Postoperatorio , Esternotomía , Humanos , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Anciano , Femenino , Bloqueo Nervioso/métodos , Bloqueo Nervioso/instrumentación , Manejo del Dolor/métodos , Puente de Arteria Coronaria/métodos , Catéteres
5.
Urolithiasis ; 52(1): 59, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38568426

RESUMEN

To evaluate the safety and efficacy of tubeless percutaneous nephrolithotomy (PCNL) in patients with Escherichia coli (E. coli) bacteriuria. We conducted a retrospective review of 84 patients with E. coli bacteriuria who underwent PCNL. Patients were divided into two groups according to whether a nephrostomy tube is placed at the end of the procedure. Preoperative clinical data, surgical outcomes, and postoperative complications were compared. Then, regression analysis of factors predicting success rate of PCNL in patients with E. coli bacteriuria was performed. After PCNL, residual fragments ≤ 4 mm were considered as success. At baseline, the two groups were similar with regard to age, gender, BMI, underlying disease, hydronephrosis, stone characteristics, and urinalysis. Postoperative fever occurred in 1 patient (3.8%) in the tubeless PCNL group, and in 5 patients (8.6%) in the conventional PCNL group (p > 0.05). There were no significant differences in terms of successful rate, decrease in hemoglobin, pain scores, blood transfusion, and hospitalization expenses. However, the tubeless PCNL group had significantly shorter operative time (60 vs. 70 min, p = 0.033), indwelling time of catheter (2 vs. 4 days, p < 0.001), and hospital stays (3 vs. 5 days, p < 0.001) than the conventional PCNL group. In the analysis of factors predicting success, the stone diameter, stone burden, and operative time were associated with success rate of PCNL. It is safe and effective to perform tubeless PCNL in patients with E. coli bacteriuria. Compared to conventional PCNL, tubeless PCNL accelerates patient recovery and shortens hospital stays.


Asunto(s)
Bacteriuria , Nefrolitotomía Percutánea , Humanos , Nefrolitotomía Percutánea/efectos adversos , Escherichia coli , Catéteres , Hospitalización
6.
J Vis Exp ; (205)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38587368

RESUMEN

Acute myocardial infarction (AMI) is a prevalent and high-mortality cardiovascular condition. Despite advancements in revascularization strategies for AMI, it frequently leads to myocardial ischemia-reperfusion injury (IRI), amplifying cardiac damage. Murine models serve as vital tools for investigating both acute injury and chronic myocardial remodeling in vivo. This study presents a unique closed-chest technique for remotely inducing myocardial IRI in mice, enabling the investigation of the very early phase of occlusion and reperfusion using in-vivo imaging such as MRI or PET. The protocol utilizes a remote occlusion method, allowing precise control over ischemia initiation after chest closure. It reduces surgical trauma, enables spontaneous breathing, and enhances experimental consistency. What sets this technique apart is its potential for simultaneous noninvasive imaging, including ultrasound and magnetic resonance imaging (MRI), during occlusion and reperfusion events. It offers a unique opportunity to analyze tissue responses in almost real-time, providing critical insights into processes during ischemia and reperfusion. Extensive systematic testing of this innovative approach was conducted, measuring cardiac necrosis markers for infarction, assessing the area at risk using contrast-enhanced MRI, and staining infarcts at the scar maturation stage. Through these investigations, emphasis was placed on the value of the proposed tool in advancing research approaches to myocardial ischemia-reperfusion injury and accelerating the development of targeted interventions. Preliminary findings demonstrating the feasibility of combining the proposed innovative experimental protocol with noninvasive imaging techniques are presented herein. These initial results highlight the benefit of utilizing the purpose-built animal cradle to remotely induce myocardial ischemia while simultaneously conducting MRI scans.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Daño por Reperfusión Miocárdica , Ratones , Animales , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Infarto del Miocardio/diagnóstico por imagen , Necrosis , Catéteres , Modelos Animales de Enfermedad
7.
J Vis Exp ; (205)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38587399

RESUMEN

Catheter-related infection (CRI) is a common nosocomial infection caused by candida albicans during catheter implantation. Typically, biofilms are formed on the outer surface of the catheter and lead to disseminated infections, which are fatal to patients. There are no effective prevention and treatment management in clinics. Therefore, it is urgent to establish an animal model of CRI for the preclinical screening of new strategies for its prevention and treatment. In this study, a polyethylene catheter, a widely used medical catheter, was inserted into the back of the BALB/c mice after hair removal. Candida albicans ATCC MYA-2876 (SC5314) expressing enhanced green fluorescent protein was subsequently inoculated on the skin's surface along the catheter. Intense fluorescence was observed on the surface of the catheter under a fluorescent microscope 3 days later. Mature and thick biofilms were found on the surface of the catheter via scanning electron microscopy. These results indicated the adhesion, colonization, and biofilm formation of candida albicans on the surface of the catheter. The hyperplasia of the epidermis and the infiltration of inflammatory cells in the skin specimens indicated the histopathological changes of the CRI-associated skin. To sum up, a mouse CRI model was successfully established. This model is expected to be helpful in the research and development of therapeutic management for candida albicans associated CRI.


Asunto(s)
Candida albicans , Infecciones Relacionadas con Catéteres , Humanos , Ratones , Animales , Catéteres , Modelos Animales de Enfermedad , Biopelículas , Antifúngicos
10.
Int Wound J ; 21(4): e14795, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38572781

RESUMEN

This study investigates the effects of comprehensive nursing interventions on wound pain in patients undergoing catheter insertion for peritoneal dialysis. Sixty patients who underwent catheter insertion for peritoneal dialysis from January 2021 to January 2023 at our hospital were selected as subjects and randomly divided into an experimental group and a control group using a random number table method. The control group received routine nursing care, while the experimental group was subjected to comprehensive nursing interventions. The study compared the impact of nursing measures on visual analogue scale (VAS), self-rating anxiety scale (SAS), self-rating depression scale (SDS) and nursing satisfaction between the two groups. The analysis revealed that on the third, fifth and seventh days post-intervention, the experimental group's wound VAS scores were significantly lower than those of the control group (p < 0.001). Furthermore, levels of anxiety and depression were markedly lower in the experimental group compared with the control group (p < 0.001). In addition, the nursing satisfaction rate was significantly higher in the experimental group than in the control group (96.67% vs. 73.33%, p = 0.011). This study indicates that the application of comprehensive nursing interventions in patients undergoing catheter insertion for peritoneal dialysis is highly effective. It can alleviate wound pain and negative emotions to a certain extent, while also achieving high patient satisfaction, thus demonstrating significant clinical value.


Asunto(s)
Dolor , Diálisis Peritoneal , Humanos , Ansiedad/etiología , Ansiedad/terapia , Trastornos de Ansiedad , Catéteres
11.
Biosens Bioelectron ; 255: 116267, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38581838

RESUMEN

External ventricular drainage is one of the most common neurosurgical procedures in the world for acute hydrocephalus, which must be performed carefully by a neurosurgeon. Although various neuromonitoring external ventricular drain (EVD) catheters have been utilized, they still suffer from rigidity and bulkiness to mitigate post-EVD placement trauma. Here, we introduce a flexible and low-profile smart EVD catheter using a class of technologies with sensitive electrical materials, seamless integration, and flexible mechanics, which serves as a highly soft and minimally invasive device to monitor electrical brain signals. This device reliably captures biopotentials in real time while exhibiting remarkable flexibility and reliability. The seamless integration of its sensory system promises a minimally invasive EVD placement on brain tissue. This work validates the device's distinct characteristics and performances through in vitro experiments and computational analysis. Collectively, this device's exceptional patient- and user-friendly attributes highlight its potential as one of the most practical EVD catheters.


Asunto(s)
Técnicas Biosensibles , Humanos , Reproducibilidad de los Resultados , Catéteres , Encéfalo , Drenaje/métodos
12.
J Int Med Res ; 52(4): 3000605241237680, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38606755

RESUMEN

Intraventricular haemorrhage (IVH) is a severe and acute type of stroke with a complex pathophysiology and is a therapeutic challenge. This case report described a man in his early 50's diagnosed with IVH by computed tomography (CT). Although bilateral extraventricular drainage (EVD) was undertaken, a postoperative CT scan showed that while the left catheter was correctly positioned, the right catheter had been wrongly inserted into the cisterna ambiens. The procedure was equivalent to simultaneous EVD combined with cisternostomy. As a consequence, the haematoma was rapidly removed, the risk of infection and long-term hydrocephalus was reduced, and prognosis was improved. Large case-control studies or prospective studies are needed to evaluate the safety and effectiveness of this treatment modality.


Asunto(s)
Hemorragia Cerebral , Hidrocefalia , Masculino , Humanos , Zolpidem/uso terapéutico , Resultado del Tratamiento , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/etiología , Hemorragia Cerebral/cirugía , Hidrocefalia/cirugía , Drenaje/métodos , Catéteres/efectos adversos
13.
Eur Rev Med Pharmacol Sci ; 28(7): 2654-2661, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38639504

RESUMEN

OBJECTIVE: This study aimed to explore the effect of flipped venous catheters combined with spinal cord electrical stimulation on functional recovery in patients with sciatic nerve injury. PATIENTS AND METHODS: 160 patients with hip dislocation and sciatic nerve injury were divided into conventional release and flipped catheter + electrical stimulation groups according to the treatment methods (n=80). Motor nerve conduction velocity (MCV) and lower limb motor function were compared. Serum neurotrophic factors brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) were compared. The frequency of complications and quality of life were also compared. RESULTS: The MCV levels of the common peroneal nerve and tibial nerve in the flipped catheter + electrical stimulation group were greater than the conventional lysis group (p<0.05). After treatment, the lower extremity motor score (LMEs) in the flipped catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). The serum levels of BDNF and NGF in the flip catheter + electrical stimulation group were higher than the conventional lysis group (p<0.05). The complication rate in the flipped catheter + electrical stimulation group was lower than in the conventional release group (6.25% vs. 16.25%, p<0.05). The quality-of-life score in the flip catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). CONCLUSIONS: The flipped venous catheter combined with spinal cord electrical stimulation can improve nerve conduction velocity, lower limb motor function, serum BDNF and NGF levels, reduce complications, and help improve the quality of life of sufferers with sciatic nerve injury. Chictr.org.cn ID: ChiCTR2400080984.


Asunto(s)
Factor Neurotrófico Derivado del Encéfalo , Neuropatía Ciática , Ratas , Animales , Humanos , Factor Neurotrófico Derivado del Encéfalo/metabolismo , Ratas Sprague-Dawley , Factor de Crecimiento Nervioso/metabolismo , Calidad de Vida , Neuropatía Ciática/metabolismo , Neuropatía Ciática/terapia , Médula Espinal/metabolismo , Nervio Ciático , Catéteres , Estimulación Eléctrica/métodos
14.
J Diabetes ; 16(4): e13536, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38599884

RESUMEN

AIMS: It is not clear whether there are differences in glycemic control between the Equil patch and the MMT-712 insulin pump. Our objective was to compare two types of insulin pumps in the treatment of type 2 diabetes mellitus (T2DM), using continuous glucose monitoring (CGM) metrics and profiles. METHODS: This was a randomized case-crossover clinical trial. Participants were hospitalized and randomly allocated to two groups and underwent two types of insulin pump treatments (group A: Equil patch-Medtronic MMT-712 insulin pump; group B: Medtronic MMT-712-Equil patch insulin pump) separated by a 1-day washout period. Glycemic control was achieved after 7-8 days of insulin pump therapy. Each patient received CGM for 5 consecutive days (from day 1 to day 5). On day 3 of CGM performance, the Equil patch insulin pump treatment was switched to Medtronic MMT-712 insulin pump treatment at the same basal and bolus insulin doses or vice versa. CGM metrics and profiles including glycemic variability (GV), time in range (TIR, 3.9-10.0 mmol/L), time below range (TBR, <3.9 mmol/L), time above range (TAR, >10.0 mmol/L), and postprandial glucose excursions, as well as incidence of hypoglycemia. RESULTS: Forty-six T2DM patients completed the study. There was no significant difference in parameters of daily GV and postprandial glucose excursions between the Equil patch insulin pump treatment and the Medtronic insulin pump treatment. Similarly, there was no between-treatment difference in TIR, TBR, and TAR, as well as the incidence of hypoglycemia. CONCLUSION: The Equil patch insulin pump was similar to the traditional MMT-712 insulin pump in terms of glycemic control. Equil patch insulin pump is a reliable tool for glycemic management of diabetes mellitus.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Catéteres , Monitoreo Continuo de Glucosa , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucosa , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Estudios Cruzados
15.
Antimicrob Resist Infect Control ; 13(1): 38, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600526

RESUMEN

BACKGROUND: Most surveillance systems for catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI) are based on manual chart review. Our objective was to validate a fully automated algorithm for CRBSI and CLABSI surveillance in intensive care units (ICU). METHODS: We developed a fully automated algorithm to detect CRBSI, CLABSI and ICU-onset bloodstream infections (ICU-BSI) in patients admitted to the ICU of a tertiary care hospital in Switzerland. The parameters included in the algorithm were based on a recently performed systematic review. Structured data on demographics, administrative data, central vascular catheter and microbiological results (blood cultures and other clinical cultures) obtained from the hospital's data warehouse were processed by the algorithm. Validation for CRBSI was performed by comparing results with prospective manual BSI surveillance data over a 6-year period. CLABSI were retrospectively assessed over a 2-year period. RESULTS: From January 2016 to December 2021, 854 positive blood cultures were identified in 346 ICU patients. The median age was 61.7 years [IQR 50-70]; 205 (24%) positive samples were collected from female patients. The algorithm detected 5 CRBSI, 109 CLABSI and 280 ICU-BSI. The overall CRBSI and CLABSI incidence rates determined by automated surveillance for the period 2016 to 2021 were 0.18/1000 catheter-days (95% CI 0.06-0.41) and 3.86/1000 catheter days (95% CI: 3.17-4.65). The sensitivity, specificity, positive predictive and negative predictive values of the algorithm for CRBSI, were 83% (95% CI 43.7-96.9), 100% (95% CI 99.5-100), 100% (95% CI 56.5-100), and 99.9% (95% CI 99.2-100), respectively. One CRBSI was misclassified as an ICU-BSI by the algorithm because the same bacterium was identified in the blood culture and in a lower respiratory tract specimen. Manual review of CLABSI from January 2020 to December 2021 (n = 51) did not identify any errors in the algorithm. CONCLUSIONS: A fully automated algorithm for CRBSI and CLABSI detection in critically-ill patients using only structured data provided valid results. The next step will be to assess the feasibility and external validity of implementing it in several hospitals with different electronic health record systems.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Infección Hospitalaria , Sepsis , Humanos , Femenino , Persona de Mediana Edad , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Estudios Prospectivos , Estudios Retrospectivos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Catéteres , Algoritmos
16.
Acta Biomater ; 180: 372-382, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38614415

RESUMEN

Catheter-induced thrombosis is a major contributor to infectious and mechanical complications of biomaterials that lead to device failure. Herein, a dualfunction submicron textured nitric oxide (NO)-releasing catheter was developed. The hemocompatibility and antithrombotic activity of vascular catheters were evaluated in both 20 h in vitro blood loop and 7 d in vivo rabbit model. Surface characterization assessments via atomic force microscopy show the durability of the submicron pattern after incorporation of NO donor S-nitroso-N-acetylpenicillamine (SNAP). The SNAP-doped catheters exhibited prolonged and controlled NO release mimicking the levels released by endothelium. Fabricated catheters showed cytocompatibility when evaluated against BJ human fibroblast cell lines. After 20h in vitro evaluation of catheters in a blood loop, textured-NO catheters exhibited a 13-times reduction in surface thrombus formation compared to the control catheters, which had 83% of the total area covered by clots. After the 7 d in vivo rabbit model, analysis on the catheter surface was examined via scanning electron microscopy, where significant reduction of platelet adhesion, fibrin mesh, and thrombi can be observed on the NO-releasing textured surfaces. Moreover, compared to relative controls, a 63% reduction in the degree of thrombus formation within the jugular vein was observed. Decreased levels of fibrotic tissue decomposition on the jugular vein and reduced platelet adhesion and thrombus formation on the texture of the NO-releasing catheter surface are indications of mitigated foreign body response. This study demonstrated a biocompatible and robust dual-functioning textured NO PU catheter in limiting fouling-induced complications for longer-term blood-contacting device applications. STATEMENT OF SIGNIFICANCE: Catheter-induced thrombosis is a major contributor to infectious and mechanical complications of biomaterials that lead to device failure. This study demonstrated a robust, biocompatible, dual-functioning textured nitric oxide (NO) polyurethane catheter in limiting fouling-induced complications for longer-term blood-contacting device applications. The fabricated catheters exhibited prolonged and controlled NO release that mimics endothelium levels. After the 7 d in vivo model, a significant reduction in platelet adhesion, fibrin mesh, and thrombi was observed on the NO-releasing textured catheters, along with decreased levels of fibrotic tissue decomposition on the jugular vein. Results illustrate that NO-textured catheter surface mitigates foreign body response.


Asunto(s)
Catéteres , Óxido Nítrico , S-Nitroso-N-Acetilpenicilamina , Animales , Conejos , Óxido Nítrico/metabolismo , Humanos , S-Nitroso-N-Acetilpenicilamina/farmacología , S-Nitroso-N-Acetilpenicilamina/química , Trombosis/patología , Ensayo de Materiales , Línea Celular , Adhesividad Plaquetaria/efectos de los fármacos , Modelos Animales de Enfermedad
17.
ACS Biomater Sci Eng ; 10(5): 3057-3068, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38641433

RESUMEN

Blood-contacting catheters play a pivotal role in contemporary medical treatments, particularly in the management of cardiovascular diseases. However, these catheters exhibit inappropriate wettability and lack antimicrobial characteristics, which often lead to catheter-related infections and thrombosis. Therefore, there is an urgent need for blood contact catheters with antimicrobial and anticoagulant properties. In this study, we employed tannic acid (TA) and 3-aminopropyltriethoxysilane (APTES) to create a stable hydrophilic coating under mild conditions. Heparin (Hep) and poly(lysine) (PL) were then modified on the TA-APTES coating surface using the layer-by-layer (LBL) technique to create a superhydrophilic TA/APTES/(LBL)4 coating on silicone rubber (SR) catheters. Leveraging the superhydrophilic nature of this coating, it can be effectively applied to blood-contacting catheters to impart antibacterial, antiprotein adsorption, and anticoagulant properties. Due to Hep's anticoagulant attributes, the activated partial thromboplastin time and thrombin time tests conducted on SR/TA-APTES/(LBL)4 catheters revealed remarkable extensions of 276 and 103%, respectively, when compared to uncoated commercial SR catheters. Furthermore, the synergistic interaction between PL and TA serves to enhance the resistance of SR/TA-APTES/(LBL)4 catheters against bacterial adherence, reducing it by up to 99.9% compared to uncoated commercial SR catheters. Remarkably, the SR/TA-APTES/(LBL)4 catheter exhibits good biocompatibility with human umbilical vein endothelial cells in culture, positioning it as a promising solution to address the current challenges associated with blood-contact catheters.


Asunto(s)
Catéteres , Materiales Biocompatibles Revestidos , Heparina , Polifenoles , Taninos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Humanos , Catéteres/microbiología , Polifenoles/química , Polifenoles/farmacología , Heparina/química , Heparina/farmacología , Taninos/química , Taninos/farmacología , Silanos/química , Silanos/farmacología , Anticoagulantes/química , Anticoagulantes/farmacología , Propilaminas/química , Aminas/química , Aminas/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Polilisina/química , Polilisina/farmacología , Propiedades de Superficie , Interacciones Hidrofóbicas e Hidrofílicas , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Elastómeros de Silicona/química , Adsorción , Escherichia coli/efectos de los fármacos
18.
Ann Biomed Eng ; 52(6): 1554-1567, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38589731

RESUMEN

Catheter reaction forces during transcatheter valve replacement (TAVR) may result in injury to the vessel or plaque rupture, triggering distal embolization or thrombosis. In vitro test methods represent the arterial wall using synthetic proxies to determine catheter reaction forces during tracking, but whether they can account for reaction forces within the compliant aortic wall tissue in vivo is unknown. Moreover, the role of plaque inclusions is not well understood. Computational approaches have predicted the impact of TAVR positioning, migration, and leaflet distortion, but have not yet been applied to investigate aortic wall reaction forces and stresses during catheter tracking. In this study, we investigate the role that catheter design and aorta and plaque mechanical properties have on the risk of plaque rupture during TAVR catheter delivery. We report that, for trackability testing, a rigid test model provides a reasonable estimation of the peak reaction forces experienced during catheter tracking within compliant vessels. We investigated the risk of rupture of both the aortic tissue and calcified plaques. We report that there was no risk of diseased aortic tissue rupture based on an accepted aortic tissue stress threshold (4.2 MPa). However, we report that both the aortic and plaque tissue exceed a rupture stress threshold (300 kPa) with and without the presence of stiff and soft plaque inclusions. We also highlight the potential risks associated with shorter catheter tips during catheter tracking and demonstrate that increasing the contact surface will reduce peak contact pressures experienced in the tissue.


Asunto(s)
Modelos Cardiovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Humanos , Aorta , Catéteres/efectos adversos , Placa Aterosclerótica
19.
Medicine (Baltimore) ; 103(16): e37849, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640270

RESUMEN

INTRODUCTION: Left-sided inferior vena cava (IVC) is an uncommon condition with a prevalence rate of 0.2% to 0.5%. Most of them remain asymptomatic and are discovered incidentally. The patient condition in this case is critical, and conventional procedures are not applicable. The surgical approach being considered is innovative, but it carries significant risks and uncertain therapeutic efficacy. PATIENT CONCERNS: A 42-year-old male presented with acute right lower extremity pain with swelling for 2 days. DIAGNOSIS: The patient was subsequently diagnosed with acute right lower extremity deep vein thrombosis, inferior vena cava thrombosis, and a left-sided IVC. INTERVENTIONS: Based on the treatment guidelines for lower extremity deep venous thrombosis. OUTCOMES: We successfully cured him with percutaneous mechanic thrombectomy (PMT) combined with catheter directed thrombolysis (CDT). CONCLUSION AND SIGNIFICANCE: The relatively low incidence of left-sided IVC does not diminish the significance of its identification. PMT combined with CDT is a safe way to treat acute thrombosis. It provides a new approach for similar patients in the future.


Asunto(s)
Terapia Trombolítica , Trombosis de la Vena , Humanos , Masculino , Adulto , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapéutico , Vena Cava Inferior , Extremidad Inferior/irrigación sanguínea , Trombosis de la Vena/tratamiento farmacológico , Trombectomía/métodos , Catéteres , Resultado del Tratamiento
20.
Sci Rep ; 14(1): 9111, 2024 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643229

RESUMEN

Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) may be useful in treating exsanguinating trauma patients. This study seeks to compare rates of success, complications and time required for vascular access between ultrasound-guidance and surgical cut-down for femoral sheath insertion as a prospective observational case control study. Participating clinicians from either trauma surgery or anesthesiology were allocated to surgical cut-down or percutaneous ultrasound-guided puncture on a 1:1 ratio. Time spans to vessel identification, successful puncture, and balloon inflation were recorded. 80 study participants were recruited and allocated to 40 open cut-down approaches and 40 percutaneous ultrasound-guided approaches. REBOA catheter placement was successful in 18/40 cases (45%) using a percutaneous ultrasound guided technique and 33/40 times (83%) using the open cut-down approach (p < 0.001). Median times [in seconds] compared between percutaneous ultrasound-guided puncture and surgical cut-down were 36 (18-73) versus 117(56-213) for vessel visualization (p < 0.001), 136 (97-175) versus 183 (156-219) for vessel puncture (p < 0.001), and 375 (240-600) versus 288 (244-379) for balloon inflation (p = 0.08) overall. Access to femoral vessels for REBOA catheter placement is safer when performed by cut-down and direct visualization but can be performed faster by an ultrasound-guided technique when vessels can be identified clearly and rapidly.


Asunto(s)
Oclusión con Balón , Procedimientos Endovasculares , Choque Hemorrágico , Humanos , Estudios de Casos y Controles , Procedimientos Endovasculares/métodos , Hemorragia/etiología , Aorta/diagnóstico por imagen , Aorta/cirugía , Resucitación/métodos , Oclusión con Balón/métodos , Catéteres/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Choque Hemorrágico/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA