Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.199
Filtrar
1.
PLoS One ; 19(7): e0305137, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38950036

RESUMEN

Electrospun (ES) fibrous nanomaterials have been widely investigated as novel biomaterials. These biomaterials have to be safe and biocompatible; hence, they need to be tested for cytotoxicity before being administered to patients. The aim of this study was to develop a suitable and biorelevant in vitro cytotoxicity assay for ES biomaterials (e.g. wound dressings). We compared different in vitro cytotoxicity assays, and our model wound dressing was made from polycaprolactone and polyethylene oxide and contained chloramphenicol as the active pharmaceutical ingredient. Baby Hamster Kidney cells (BHK-21), human primary fibroblasts and MTS assays together with real-time cell analysis were selected. The extract exposure and direct contact safety evaluation setups were tested together with microscopic techniques. We found that while extract exposure assays are suitable for the initial testing, the biocompatibility of the biomaterial is revealed in in vitro direct contact assays where cell interactions with the ES wound dressing are evaluated. We observed significant differences in the experimental outcome, caused by the experimental set up modification such as cell line choice, cell medium and controls used, conducting the phosphate buffer washing step or not. A more detailed technical protocol for the in vitro cytotoxicity assessment of ES wound dressings was developed.


Asunto(s)
Vendajes , Materiales Biocompatibles , Cicatrización de Heridas , Animales , Cicatrización de Heridas/efectos de los fármacos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Humanos , Línea Celular , Ensayo de Materiales , Cricetinae , Poliésteres/química , Fibroblastos/efectos de los fármacos , Antiinfecciosos/farmacología , Polietilenglicoles/química , Cloranfenicol/farmacología
2.
Talanta ; 277: 126430, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38878510

RESUMEN

In the present work, we developed an aptasensor to determine chloramphenicol (CAP) based on the dual signal output of photoelectrochemistry (PEC) and colorimetry. The Fe3+-doped porous tungsten trioxide was prepared by sol-gel method and coated on the ITO conductive glass to form ITO/p-W(Fe)O3. After assembling the captured DNA (cDNA) and the aptamer of CAP (apt) successively, the constructed ITO/p-W(Fe)O3-cDNA/apt aptasensor exhibited excellent photocurrent response under visible light irradiation in the presence of glucose, which provided the feasibility for PEC measurement with high sensitivity. In the presence of CAP, the apt left the ITO/p-W(Fe)O3 surface and AuNPs linked on the probe DNA would be assembled on it, which led to the decrease of photocurrent. Thanks to the oxidase-mimic catalytic performance of AuNPs and the recycling catalytic hydrolysis by exonuclease I, the measurement signal of the aptasensor could be amplified significantly, and the photocurrent decrease of the aptasensor was linearly related to the concentration of CAP in the range of 1.0 pM-10.0 nM and low detection limit was 0.36 pM. Meanwhile, the H2O2 produced from catalytic oxidation of glucose could oxidize TMB to blue oxTMB under HRP catalysis, which absorbance at 652 nm was linearly related to the concentration of CAP in the range of 5.0 pM-10.0 nM and low detection limit was 1.72 pM. Therefore, an aptasensor that determine CAP in real samples was successfully constructed with good precision of the relative standard deviation less than 5.7 % for PEC method and 7.3 % for colorimetric method, which can meet the analysis needs in different scenarios.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Cloranfenicol , Colorimetría , Técnicas Electroquímicas , Oro , Nanopartículas del Metal , Cloranfenicol/análisis , Cloranfenicol/química , Aptámeros de Nucleótidos/química , Colorimetría/métodos , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Oro/química , Nanopartículas del Metal/química , Límite de Detección , Óxidos/química , Procesos Fotoquímicos , Antibacterianos/análisis , Antibacterianos/química , Tungsteno
3.
J Colloid Interface Sci ; 672: 236-243, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38838631

RESUMEN

This study reports the development of a photocatalytic electrochemical aptasensor for the purpose of detecting chloramphenicol (CAP) antibiotic residues in water by utilizing SYBR Green I (SG) and chemically exfoliated MoS2 (ce-MoS2) as synergistically signal-amplification platforms. The Au nanoparticles (AuNPs) were electrodeposited onto the surface of an indium tin oxide (ITO) electrode. After that, the thiolate-modified cDNA, also known as capture DNA, was combined with the aptamer. Subsequently, photosensitized SG molecules and ce-MoS2 nanomaterial were inserted into the groove of the resultant double-stranded DNA (dsDNA). The activation of the photocatalytic process upon exposure to light resulted in the generation of singlet oxygen. The singlet oxygen effectively split the dsDNA, resulting in significant enhancement in the current of [Fe(CN)6]3-/4-. When the CAP was present, both SG molecules and ce-MoS2 broke away from the dsDNA, which turned off the photosensitization response, leading to significant reduction in the current of [Fe(CN)6]3-/4-. Under the optimal conditions, the aptasensor exhibited a linear relationship between the current of [Fe(CN)6]3-/4- with logarithmic concentrations of CAP from 20 to 1000 nM, with a detection of limit (3σ) of 3.391 nM. The aptasensor also demonstrated good selectivity towards CAP in the presence of interfering antibiotics, such as tetracycline, streptomycin, levofloxacin, ciprofloxacin, and sulfadimethoxine. Additionally, the results obtained from the analysis of natural water samples using the proposed aptasensor were consistent with the findings acquired through the use of a liquid chromatograph-mass spectrometer. Therefore, with its simplicity and high selectivity, this aptasensor can potentially detect alternative antibiotics in environmental water samples by replacing the aptamers based on photosensitization.


Asunto(s)
Aptámeros de Nucleótidos , Benzotiazoles , Técnicas Biosensibles , Cloranfenicol , Diaminas , Disulfuros , Técnicas Electroquímicas , Molibdeno , Compuestos Orgánicos , Quinolinas , Cloranfenicol/análisis , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Molibdeno/química , Diaminas/química , Disulfuros/química , Benzotiazoles/química , Quinolinas/química , Compuestos Orgánicos/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Oro/química , Fármacos Fotosensibilizantes/química , Antibacterianos/análisis , Límite de Detección , Contaminantes Químicos del Agua/análisis , Procesos Fotoquímicos , Tamaño de la Partícula
4.
Arch Microbiol ; 206(7): 298, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38860999

RESUMEN

A decreased chloramphenicol susceptibility in Haemophilus influenzae is commonly caused by the activity of chloramphenicol acetyltransferases (CATs). However, the involvement of membrane proteins in chloramphenicol susceptibility in H. influenzae remains unclear. In this study, chloramphenicol susceptibility testing, whole-genome sequencing, and analyses of membrane-related genes were performed in 51 H. influenzae isolates. Functional complementation assays and structure-based protein analyses were conducted to assess the effect of proteins with sequence substitutions on the minimum inhibitory concentration (MIC) of chloramphenicol in CAT-negative H. influenzae isolates. Six isolates were resistant to chloramphenicol and positive for type A-2 CATs. Of these isolates, A3256 had a similar level of CAT activity but a higher chloramphenicol MIC relative to the other resistant isolates; it also had 163 specific variations in 58 membrane genes. Regarding the CAT-negative isolates, logistic regression and receiver operator characteristic curve analyses revealed that 48T > G (Asn16Lys), 85 C > T (Leu29Phe), and 88 C > A (Leu30Ile) in HI_0898 (emrA), and 86T > G (Phe29Cys) and 141T > A (Ser47Arg) in HI_1177 (artM) were associated with enhanced chloramphenicol susceptibility, whereas 997G > A (Val333Ile) in HI_1612 (hmrM) was associated with reduced chloramphenicol susceptibility. Furthermore, the chloramphenicol MIC was lower in the CAT-negative isolates with EmrA-Leu29Phe/Leu30Ile or ArtM-Ser47Arg substitution and higher in those with HmrM-Val333Ile substitution, relative to their counterparts. The Val333Ile substitution was associated with enhanced HmrM protein stability and flexibility and increased chloramphenicol MICs in CAT-negative H. influenzae isolates. In conclusion, the substitution in H. influenzae multidrug efflux pump HmrM associated with reduced chloramphenicol susceptibility was characterised.


Asunto(s)
Sustitución de Aminoácidos , Antibacterianos , Proteínas Bacterianas , Cloranfenicol O-Acetiltransferasa , Cloranfenicol , Haemophilus influenzae , Pruebas de Sensibilidad Microbiana , Cloranfenicol/farmacología , Haemophilus influenzae/genética , Haemophilus influenzae/efectos de los fármacos , Haemophilus influenzae/metabolismo , Haemophilus influenzae/aislamiento & purificación , Antibacterianos/farmacología , Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Cloranfenicol O-Acetiltransferasa/genética , Cloranfenicol O-Acetiltransferasa/metabolismo , Farmacorresistencia Bacteriana Múltiple/genética , Proteínas de Transporte de Membrana/genética , Proteínas de Transporte de Membrana/metabolismo , Resistencia al Cloranfenicol/genética , Humanos , Infecciones por Haemophilus/microbiología , Secuenciación Completa del Genoma
5.
Anal Methods ; 16(24): 3867-3877, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38828675

RESUMEN

A Ti3C2Tx/MoS2/MWCNT@rGONR nanocomposite was prepared for the first time for building a sensitive electrochemical aptasening platform to simultaneously detect kanamycin (Kana) and chloramphenicol (Cap). Owing to their accordion-like structure, rich surface groups, and high charge mobility, Ti3C2Tx/MoS2/MWCNT@rGONR composites provided a spacious covalent immobilization surface and a better electrochemical aptasensing platform. The aptamers of Kana and Cap used in sensors enhance the selectivity. Furthermore, TiP, an ion exchanger, was used for loading more different metal ions functioning as labels to form a sandwich-type sensor together with Ti3C2Tx/MoS2/MWCNT@rGONR, improving the electrochemical sensitivity and obtaining a highly distinguishable signal readout. Under the optimized conditions, the sensor has good detection limits of 0.135 nmol L-1 and 0.173 nmol L-1 for Kana and Cap, respectively, at the same linearity concentration of 0.5-2500 nmol L-1. Finally, it was successfully applied for detection in milk and fish meat, and the results were compared with the standard method HPLC, indicating its great potential for food safety monitoring.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Cloranfenicol , Técnicas Electroquímicas , Contaminación de Alimentos , Kanamicina , Leche , Titanio , Cloranfenicol/análisis , Cloranfenicol/química , Kanamicina/análisis , Kanamicina/química , Técnicas Electroquímicas/métodos , Aptámeros de Nucleótidos/química , Titanio/química , Animales , Leche/química , Contaminación de Alimentos/análisis , Técnicas Biosensibles/métodos , Molibdeno/química , Límite de Detección , Nanotubos de Carbono/química , Grafito/química , Nanocompuestos/química , Análisis de los Alimentos/métodos , Antibacterianos/análisis , Antibacterianos/química , Peces , Disulfuros
6.
Eur J Clin Microbiol Infect Dis ; 43(8): 1667-1671, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38913228

RESUMEN

Limited literature exists on chloramphenicol's clinical use. In this retrospective, single-center case-series, we examined 183 chloramphenicol-treated and 81 piperacillin-tazobactam-treated medical patients. Chloramphenicol recipients were older, more debilitated, cognitively impaired, and penicillin allergic, while increased need for inotropics, higher leukocyte count, and higher creatinine levels were notable in the piperacillin-tazobactam group. Pneumonia was the most common indication, with no mortality difference between groups. While acknowledging its antimicrobial activity and potential benefit in specific conditions such as pneumonia, further clinical studies are needed to assess the role of chloramphenicol in the setting where other alternatives are available.


Asunto(s)
Antibacterianos , Cloranfenicol , Humanos , Cloranfenicol/uso terapéutico , Estudios Retrospectivos , Antibacterianos/uso terapéutico , Masculino , Anciano , Femenino , Persona de Mediana Edad , Anciano de 80 o más Años , Hospitalización/estadística & datos numéricos , Resultado del Tratamiento , Combinación Piperacilina y Tazobactam/uso terapéutico , Adulto , Demografía
7.
Food Chem ; 454: 139806, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38820635

RESUMEN

Misuse of chloramphenicol (CAP) can lead to severe food safety issues. Therefore, the accurate and sensitive detection of CAP residues is important for public health. Herein, a convenient and reliable interfacial self-assembly technique was used to form a uniform Au@Ag nanobipyramids (NBPs) film on an ordered SiO2 nanosphere array (SiO2 NS), which served as a Raman-enhanced substrate. In conjunction with a deoxyribonucleic acid enzyme-induced signal amplification strategy, we developed a novel surface-enhanced Raman scattering (SERS) biosensor for the selective and sensitive detection of CAP. The biosensor exhibited a detection limit of 6.42 × 10-13 mol·L-1 and a detection range of 1.0 × 10-12-1.0 × 10-6 mol·L-1. The biosensor could detect CAP in spiked milk samples with a high accuracy, and its recovery rates ranged from 97.88% to 107.86%. The as-developed biosensor with the advantages of high sensitivity and high selectivity offers a new strategy for the rapid, reliable and sensitive detection of CAP, rendering it applicable to food safety control.


Asunto(s)
Técnicas Biosensibles , Cloranfenicol , ADN Catalítico , Contaminación de Alimentos , Oro , Límite de Detección , Leche , Dióxido de Silicio , Plata , Espectrometría Raman , Dióxido de Silicio/química , Cloranfenicol/análisis , Oro/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Plata/química , Espectrometría Raman/métodos , Espectrometría Raman/instrumentación , Contaminación de Alimentos/análisis , Leche/química , ADN Catalítico/química , Animales , Nanopartículas del Metal/química , Antibacterianos/análisis
8.
J Appl Microbiol ; 135(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38760884

RESUMEN

AIMS: Enterococcus faecalis (E. faecalis) is a leading cause of nosocomial infection and presents a wide spectrum of antibiotic resistance, being vancomycin-resistant Enterococcus (VRE) one of the most relevant. Synthetic antimicrobial peptides (SAMPs) are currently a promising option to overcome antimicrobial resistance. Thus, the purpose of this study was to assess the effect of eight SAMPs against vancomycin-resistant E. faecalis, as well as to investigate their mechanism of action and synergy with conventional antibiotics. METHODS AND RESULTS: Here, eight SAMPs, Mo-CBP3-PepI, Mo-CBP3-PepII, Mo-CBP3-PepIII, RcAlb-PepI, RcAlb-PepII, RcAlb-PepIII, PepGAT, and PepKAA, were tested for antibacterial activity in vitro against E. faecalis (ATCC® 51299) through broth microdilution. A maximum of 48% of E. faecalis growth inhibition was achieved by treatment with SAMPs alone. However, when these peptides were combined with the antibiotic chloramphenicol, assessed by checkerboard method, the inhibition increased to 55%-76% of inhibition, two to three-folds of increase if compared to the effects of the compounds alone. Microscopic analysis showed that E. faecalis cells treated with a combination of SAMPs and chloramphenicol resulted in bacterial membrane damage. The biofilm inhibition maximum was 22% for SAMPs alone, when combined with chloramphenicol, the maximum increased to 33%. CONCLUSIONS: SAMPs and their combination with chloramphenicol demonstrate antibacterial activity against E. faecalis, possibly by inducing bacterial membrane damage.


Asunto(s)
Antibacterianos , Péptidos Antimicrobianos , Cloranfenicol , Sinergismo Farmacológico , Enterococcus faecalis , Pruebas de Sensibilidad Microbiana , Enterococos Resistentes a la Vancomicina , Enterococcus faecalis/efectos de los fármacos , Enterococcus faecalis/crecimiento & desarrollo , Antibacterianos/farmacología , Cloranfenicol/farmacología , Péptidos Antimicrobianos/farmacología , Enterococos Resistentes a la Vancomicina/efectos de los fármacos , Vancomicina/farmacología
9.
J Hazard Mater ; 473: 134698, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38788587

RESUMEN

Zero-valent iron (ZVI) has been extensively studied for its capacity to remove various contaminants in the environments. However, whether ZVI affects bacterial resistance to antibiotics has not been fully explored. Herein, it was unexpected that, compared with microscale ZVI (mZVI), nanoscale ZVI (nZVI) facilitated the susceptibility of Pseudomonas aeruginosa (P. aeruginosa) to chloramphenicol (CAP), with a decrease in the minimal inhibitory concentration (MIC) of about 60 %, demonstrating a nanosize-specific effect. nZVI enhanced CAP accumulation in P. aeruginosa via inhibitory effect on efflux pumps activated by MexT, thus conferring the susceptibility of P. aeruginosa to CAP. Circular dichroism spectroscopy revealed that the structure of MexT was changed during the evolution. More importantly, molecular dynamic simulations uncovered that, once the structure of MexT changed, it would be more likely to interact with nZVI, resulting in more serious changes in its secondary structure, which was consistent with the increasing susceptibility of P. aeruginosa to CAP. Collectively, this study elucidated the size-specific effect and the underlying mechanism of ZVI on the bacterial evolution of susceptibility toward antibiotics, highlighting the potentials of nZVI-based technologies on the prevention of bacterial resistance to antibiotics, one of the most important issue for globally public health.


Asunto(s)
Antibacterianos , Cloranfenicol , Farmacorresistencia Bacteriana , Hierro , Pruebas de Sensibilidad Microbiana , Pseudomonas aeruginosa , Pseudomonas aeruginosa/efectos de los fármacos , Cloranfenicol/farmacología , Cloranfenicol/química , Antibacterianos/farmacología , Antibacterianos/química , Hierro/química , Farmacorresistencia Bacteriana/efectos de los fármacos , Nanopartículas del Metal/química , Simulación de Dinámica Molecular , Proteínas Bacterianas/metabolismo , Proteínas Bacterianas/química , Proteínas Bacterianas/genética
10.
Food Chem ; 454: 139650, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38788478

RESUMEN

Inspired by the desert beetle, a novel biomimetic chip was developed to detect chloramphenicol (CP). The chip was characterized by a periodic array in which hydrophobic Au nanoparticles (AuNPs) were semi-embedded on hydrophilic polymethyl methacrylate (PMMA) spheres. Among them, the AuNPs exhibited both a localized surface plasmon resonance effect to amplify the reflected signal and a synergistic effect with PMMA spheres to create a significant hydrophilic-hydrophobic interface, which facilitated the enrichment of target CP molecules and improved sensitivity. After optimization, the chip showed direct, ultrasensitive (as low as 0.2 ng/mL), fast (5 min), and selective detection of CP with a wide concentration range extending from 0.2 ng/mL to 1000 ng/mL. During detection, color changes of the chip were observed by naked eyes without any color display equipment. The recovery of CP was between 94.65 % and 108.70 % in chicken and milk samples.


Asunto(s)
Pollos , Cloranfenicol , Escarabajos , Contaminación de Alimentos , Oro , Nanopartículas del Metal , Leche , Cloranfenicol/análisis , Cloranfenicol/química , Animales , Oro/química , Nanopartículas del Metal/química , Escarabajos/química , Contaminación de Alimentos/análisis , Leche/química , Antibacterianos/análisis , Antibacterianos/química , Coloides/química
11.
BMJ Case Rep ; 17(5)2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38719269

RESUMEN

A middle-aged male patient presented with a central corneal perforation in a deep stromal infiltrate in his left eye. An emergency therapeutic penetrating keratoplasty was performed. Microbiological evaluation of the corneal scraping specimen revealed septate fungal filaments on stains. However, culture reports after 24 hours from the scraping sample and the excised half corneal button showed growth of gram-negative bacilli. This pathogen was identified as an aerobic, non-fermentative, gram-negative, bacillus by conventional microbiology and confirmed as Myroides species by the VITEK 2 Compact system (bioMérieux, Marcy l'Etoile, France). Susceptibility to chloramphenicol was noted based on which the patient was treated with topical chloramphenicol 0.5%. No recurrence of the infection was noted. This is the first reported case of corneal infection with the Myroides species of bacteria which, heretofore, have been known to cause endocarditis and urinary tract infections.


Asunto(s)
Infecciones Fúngicas del Ojo , Queratitis , Humanos , Masculino , Persona de Mediana Edad , Queratitis/microbiología , Queratitis/diagnóstico , Queratitis/tratamiento farmacológico , Infecciones Fúngicas del Ojo/microbiología , Infecciones Fúngicas del Ojo/diagnóstico , Infecciones Fúngicas del Ojo/tratamiento farmacológico , Antibacterianos/uso terapéutico , Queratoplastia Penetrante , Cloranfenicol/uso terapéutico , Cloranfenicol/administración & dosificación , Infecciones Bacterianas del Ojo/microbiología , Infecciones Bacterianas del Ojo/diagnóstico , Infecciones Bacterianas del Ojo/tratamiento farmacológico , Perforación Corneal/microbiología , Perforación Corneal/diagnóstico
12.
J Pharm Biomed Anal ; 245: 116165, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38701534

RESUMEN

Due to antimicrobial resistance that occurs throughout the world, antibiotic-releasing hydrogel with at least two drugs that synergistically treat stubborn bacteria is preferable for infection prevention. Hydrogel can serve as a drug reservoir to gradually release drugs in a therapeutic window to effectively treat microorganisms with minimal side effects. The study and development of drug releasing hydrogels requires a reliable, straightforward, cost-effective, fast, and low labor-intensive drug detection technique. In this study, we validate the electrochemical technique and device setup for real-time determination of dual antibacterial drugs released from a hydrogel. Concentrations of two representative antibacterial drugs, tetracycline (TC) and chloramphenicol (CAP), were determined using square wave voltammetry (SWV) mode that yields the lower limit of detection at 2.5 µM for both drugs. Measurement accuracy and repeatability were verified by 36 known drug combination concentrations. Capability in long-term measurement was confirmed by the measurement stability which was found to last for at least 72 h. Stirring was revealed as one of the significant factors for accurate real-time detection. Real-time measurement was ultimately performed to demonstrate the determination of multiple drug releases from a drug releasing hydrogel and validated by high-performance liquid chromatography (HPLC). All the results support that the electrochemical technique with the proposed device design and setup can be used to accurately and simultaneously determine dual drugs that are released from a hydrogel in real-time.


Asunto(s)
Antibacterianos , Cloranfenicol , Liberación de Fármacos , Técnicas Electroquímicas , Hidrogeles , Tetraciclina , Antibacterianos/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Hidrogeles/química , Tetraciclina/análisis , Cloranfenicol/análisis , Límite de Detección , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados
13.
Curr Microbiol ; 81(6): 166, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724665

RESUMEN

Many regulatory genes that affect cellular development in Streptomyces, such as the canonical bld genes, have already been identified. However, in this study, we identified sven_5003 in Streptomyces venezuelae as a major new developmental regulatory gene, the deletion of which leads to a bald phenotype, typical of bld mutants, under multiple growth conditions. Our data indicated that disruption of sven_5003 also has a differential impact on the production of the two antibiotics jadomycin and chloramphenicol. Enhanced production of jadomycin but reduced production of chloramphenicol were detected in our sven_5003 mutant strain (S. venezuelae D5003). RNA-Seq analysis indicated that SVEN_5003 impacts expression of hundreds of genes, including genes involved in development, primary and secondary metabolism, and genes of unknown function, a finding confirmed by real-time PCR analysis. Transcriptional analysis indicated that sven_5003 is an auto-regulatory gene, repressing its own expression. Despite the evidence indicating that SVEN_5003 is a regulatory factor, a putative DNA-binding domain was not predicted from its primary amino acid sequence, implying an unknown regulatory mechanism by SVEN_5003. Our findings revealed that SVEN_5003 is a pleiotropic regulator with a critical role in morphological development in S. venezuelae.


Asunto(s)
Antibacterianos , Proteínas Bacterianas , Regulación Bacteriana de la Expresión Génica , Streptomyces , Streptomyces/genética , Streptomyces/metabolismo , Streptomyces/crecimiento & desarrollo , Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Antibacterianos/farmacología , Cloranfenicol/farmacología , Isoquinolinas/metabolismo
14.
Anal Chim Acta ; 1307: 342631, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719408

RESUMEN

BACKGROUND: Simultaneous detection of food contaminants is crucial in addressing the collective health hazards arising from the presence of multiple contaminants. However, traditional multi-competitive surface-enhanced Raman scattering (SERS) aptasensors face difficulties in achieving simultaneous accurate detection of multiple target substances due to the uncontrollable SERS "hot spots". In this study, using chloramphenicol (CAP) and estradiol (E2) as two target substances, we introduced a novel approach that combines machine learning methods with a dual SERS aptasensor, enabling simultaneous high-sensitivity and accurate detection of both target substances. RESULTS: The strategy effectively minimizes the interference from characteristic Raman peaks commonly encountered in traditional multi-competitive SERS aptasensors. For this sensing system, the Au@4-MBA@Ag nanoparticles modified with sulfhydryl (SH)-CAP aptamer and Au@DTNB@Ag NPs modified with sulfhydryl (SH)-E2 aptamer were used as signal probes. Additionally, Fe3O4@Au nanoflowers integrated with SH-CAP aptamer complementary DNA and SH-E2 aptamer complementary DNA were used as capture probes, respectively. When compared to linear regression random forest, and support vector regression (SVR) models, the proposed artificial neural network (ANN) model exhibited superior precision, demonstrating R2 values of 0.963, 0.976, 0.991, and 0.970 for the training set, test set, validation set, and entire dataset, respectively. Validation with ten spectral groups reported an average error of 244 µg L-1. SIGNIFICANCE: The essence of our study lies in its capacity to address a persistent challenge encountered by traditional multiple competitive SERS aptasensors - the interference generated by uncontrollable SERS "hot spots" that hinders simultaneous quantification. The accuracy of the predictive model for simultaneous detection of two target substances was significantly improved using machine learning tools. This innovative technique offers promising avenues for the accurate and high-sensitive simultaneous detection of multiple food and environmental contaminants.


Asunto(s)
Aptámeros de Nucleótidos , Oro , Aprendizaje Automático , Nanopartículas del Metal , Plata , Espectrometría Raman , Aptámeros de Nucleótidos/química , Plata/química , Oro/química , Nanopartículas del Metal/química , Cloranfenicol/análisis , Estradiol/análisis , Técnicas Biosensibles/métodos , Contaminación de Alimentos/análisis , Límite de Detección
15.
Anal Chim Acta ; 1306: 342598, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692791

RESUMEN

BACKGROUND: Carbon-based nanozymes have recently received enormous concern, however, there is still a huge challenge for inexpensive and large-scale synthesis of magnetic carbon-based "Two-in-One" mimics with both peroxidase (POD)-like and laccase-like activities, especially their potential applications in multi-mode sensing of antibiotics and neurotransmitters in biofluids. Although some progresses have been made in this field, the feasibility of biomass-derived carbon materials with both POD-like and laccase-like activities by polyatomic doping strategy is still unclear. In addition, multi-mode sensing platform can provide a more reliable result because of the self-validation, self-correction and mutual agreement. Nevertheless, the use of magnetic carbon-based nanozyme sensors for the multi-mode detection of antibiotics and neurotransmitters have not been investigated. RESULTS: We herein report a shrimp shell-derived N, O-codoped porous carbon confined magnetic CuFe2O4 nanosphere with outstanding laccase-like and POD-like activities for triple-mode sensing of antibiotic d-penicillamine (D-PA) and chloramphenicol (CPL), as well as colorimetric detection of neurotransmitters in biofluids. The magnetic CuFe2O4/N, O-codoped porous carbon (MCNPC) armored mimetics was successfully fabricated using a combined in-situ coordination and high-temperature crystallization method. The synthesized MCNPC composite with superior POD-like activity can be used for colorimetric/temperature/smartphone-based triple-mode detection of D-PA and CPL in goat serum. Importantly, the MCNPC nanozyme can also be used for colorimetric analysis of dopamine and epinephrine in human urine. SIGNIFICANCE: This work not only offered a novel strategy to large-scale, cheap synthesize magnetic carbon-based "Two-in-One" armored mimetics, but also established the highly sensitive and selective platforms for triple-mode monitoring D-PA and CPL, as well as colorimetric analysis of neurotransmitters in biofluids without any tanglesome sample pretreatment.


Asunto(s)
Antibacterianos , Carbono , Cobre , Neurotransmisores , Carbono/química , Antibacterianos/análisis , Antibacterianos/orina , Antibacterianos/sangre , Neurotransmisores/orina , Neurotransmisores/análisis , Neurotransmisores/sangre , Porosidad , Cobre/química , Humanos , Nanosferas/química , Colorimetría/métodos , Compuestos Férricos/química , Materiales Biomiméticos/química , Animales , Técnicas Biosensibles/métodos , Cloranfenicol/análisis , Cloranfenicol/orina , Límite de Detección
16.
PLoS One ; 19(5): e0304250, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38787814

RESUMEN

This study aimed to investigate the potential mechanisms associated with the persistence of chloramphenicol (CHP) resistance in Escherichia coli and Salmonella enterica isolated from pigs, pork, and humans in Thailand. The CHP-resistant E. coli (n = 106) and Salmonella (n = 57) isolates were tested for their CHP susceptibility in the presence and absence of phenylalanine arginine ß-naphthylamide (PAßN). The potential co-selection of CHP resistance was investigated through conjugation experiments. Whole genome sequencing (WGS) was performed to analyze the E. coli (E329, E333, and E290) and Salmonella (SA448, SA461, and SA515) isolates with high CHP MIC (32-256 µg/mL) and predominant plasmid replicon types. The presence of PAßN significantly reduced the CHP MICs (≥4-fold) in most E. coli (67.9%) and Salmonella (64.9%). Ampicillin, tetracycline, and streptomycin co-selected for CHP-resistant Salmonella and E. coli-transconjugants carrying cmlA. IncF plasmids were mostly detected in cmlA carrying Salmonella (IncFIIAs) and E. coli (IncFIB and IncF) transconjugants. The WGS analysis revealed that class1 integrons with cmlA1 gene cassette flanked by IS26 and TnAs1 were located on IncX1 plasmid, IncFIA(HI1)/HI1B plasmids and IncFII/FIB plasmids. IncFIA(HI1)/HI1B/Q1in SA448 contained catA flanked by IS1B and TnAs3. In conclusion, cross resistance through proton motive force-dependent mechanisms and co-selection by other antimicrobial agents involved the persistence of CHP-resistance in E. coli in this collection. Dissemination of CHP-resistance genes was potentially facilitated by mobilization via mobile genetic elements.


Asunto(s)
Escherichia coli , Pruebas de Sensibilidad Microbiana , Plásmidos , Animales , Escherichia coli/genética , Escherichia coli/efectos de los fármacos , Tailandia , Porcinos , Humanos , Plásmidos/genética , Salmonella/genética , Salmonella/efectos de los fármacos , Antibacterianos/farmacología , Resistencia al Cloranfenicol/genética , Cloranfenicol/farmacología , Secuenciación Completa del Genoma
17.
Se Pu ; 42(5): 474-480, 2024 Apr 08.
Artículo en Chino | MEDLINE | ID: mdl-38736391

RESUMEN

A method was established for the simultaneous detection of 12 prohibited veterinary drugs, including ß2-receptor agonists, nitrofuran metabolites, nitroimidazoles, chlorpromazine, and chloramphenicol, in pig urine. The sample was pretreated by enzymolysis, acid hydrolysis/derivatization, and liquid-liquid extraction combined with solid-phase extraction. Detection was performed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Ammonium acetate solution (0.2 mol/L, 4.5 mL) and ß-glucuronidase/aryl sulfatase (40 µL) were added to the sample, which was subsequently enzymolized at 37 ℃ for 2 h. Then, 1.5 mL of 1.0 mol/L hydrochloric acid solution and 100 µL of 0.1 mol/L o-nitrobenzaldehyde solution were added to the sample. The mixture was incubated at 37 ℃ for 16 h, and the analytes were extracted with 8 mL of ethyl acetate by liquid-liquid extraction. The lower aqueous phase obtained after extraction was extracted and purified using a mixed cation-exchange solid-phase extraction column. The extracts were combined, the extraction solution was blow-dried with nitrogen, and the residue was redissolved for determination. The samples were analyzed under multiple-reaction monitoring mode with both positive and negative electrospray ionization, and quantified using an isotope internal standard method. The correlation coefficients (r) of the 12 compounds were >0.99. The limits of detection (LODs) and quantification (LOQs) of chloramphenicol were 0.05 and 0.1 µg/L, respectively, and the LODs and LOQs of the other compounds were 0.25 and 0.5 µg/L, respectively. The mean recoveries and RSDs at 1, 2, and 10 times the LOQ were 83.6%-115.3% and 2.20%-12.34%, respectively. The proposed method has the advantages of high sensitivity, good stability, and accurate quantification; thus, it is suitable for the simultaneous determination of the 12 prohibited veterinary drug residues in pig urine.


Asunto(s)
Residuos de Medicamentos , Espectrometría de Masas en Tándem , Drogas Veterinarias , Animales , Espectrometría de Masas en Tándem/métodos , Porcinos , Cromatografía Líquida de Alta Presión/métodos , Drogas Veterinarias/orina , Drogas Veterinarias/análisis , Residuos de Medicamentos/análisis , Cloranfenicol/orina , Cloranfenicol/análisis
18.
Anal Methods ; 16(21): 3430-3437, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38766841

RESUMEN

Two levels of nucleic acids-based isothermal amplification normally require a long reaction time due to the low concentration of catalyst, which limits its practical application. A sensitive fluorescence assay of chloramphenicol (CAP) was developed coupled with two-level isothermal amplification using a self-powered catalyzed hairpin assembly (CHA) and entropy-driven circuit (EDC). CAP can bind with its aptamer to open its closed structure. The opened hairpin can initiate self-powered CHA and EDC. The product of CHA can circularly catalyze the CHA with increasing concentration. In principle, the product of CHA plays the role of catalyst and increases with the progression of the reaction. Compared with the normal two levels of amplification, the amplification efficiency of our strategy is much higher due to the self-powered reaction by the CHA product. Thus, the reaction time is shortened to 110 min in this strategy. Moreover, the detection limit for CAP can achieve 0.1 pM and shows promising prospects for practical application.


Asunto(s)
Cloranfenicol , Entropía , Límite de Detección , Técnicas de Amplificación de Ácido Nucleico , Cloranfenicol/análisis , Cloranfenicol/química , Técnicas de Amplificación de Ácido Nucleico/métodos , Catálisis , Espectrometría de Fluorescencia/métodos , Fluorescencia , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Técnicas de Diagnóstico Molecular
19.
Chemosphere ; 359: 142304, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38734253

RESUMEN

Toxic organic and heavy metal contaminants commonly exist in industrial waste stream(s) and treatment is of great challenge. In this study, a dielectric barrier discharge (DBD) non-thermal plasma technology was employed for the simultaneous treatment of two important contaminants, chloramphenicol (CAP) and Cr(VI) in an aqueous solution through redox transformations. More than 70% of CAP and 20% of TOC were degraded in 60 min, while Cr(VI) was completely removed in 10 min. The hydroxyl radicals were the main active species for the degradation. Meanwhile, the consumption of hydroxyl radicals was beneficial to the reduction of Cr(VI). The synergistic effect was investigated between CAP degradation and Cr(VI) reduction. The reduction of Cr(VI) would be enhanced in the presence of CAP with a low concentration and could be inhibited under a high concentration, because part of hydroxyl radicals could be consumed by the low-concentration CAP and the obtained intermediates with a higher kinetic rate. However, CAP with a high concentration could react with such reductive species as eaq- and •H, which could compete with Cr(VI) and inhibit the reduction. In addition, the presence of Cr(VI) enhanced the degradation and mineralization of CAP; the study of obtained intermediates indicated that the presence of Cr(VI) changed the degradation path of CAP as Cr(VI) would react with reductive species, enhance the generation of hydroxyl radicals, and cause more hydroxylation reactions. Moreover, the mechanism for the simultaneous redox transformations of CAP and Cr(VI) was illustrated. This study indicates that the DBD non-thermal plasma technology can be one of better solutions for simultaneous elimination of heavy metal and organic contaminants in aquatic environments.


Asunto(s)
Cloranfenicol , Cromo , Oxidación-Reducción , Contaminantes Químicos del Agua , Cloranfenicol/química , Cromo/química , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/análisis , Gases em Plasma/química , Radical Hidroxilo/química , Eliminación de Residuos Líquidos/métodos
20.
Curr Microbiol ; 81(5): 136, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38598029

RESUMEN

Copper resistance in phytopathogens is a major challenge to crop production globally and is known to be driven by excessive use of copper-based pesticides. However, recent studies have shown co-selection of multiple heavy metal and antibiotic resistance genes in bacteria exposed to heavy metal and xenobiotics, which may impact the epidemiology of plant, animal, and human diseases. In this study, multi-resistance to heavy metals and antibiotics were evaluated in local Xanthomonas campestris pv. campestris (Xcc) and co-isolated Xanthomonas melonis (Xmel) strains from infected crucifer plants in Trinidad. Resistance to cobalt, cadmium, zinc, copper, and arsenic (V) was observed in both Xanthomonas species up to 25 mM. Heavy metal resistance (HMR) genes were found on a small plasmid-derived locus with ~ 90% similarity to a Stenotrophomonas spp. chromosomal locus and a X. perforans pLH3.1 plasmid. The co-occurrence of mobile elements in these regions implies their organization on a composite transposon-like structure. HMR genes in Xcc strains showed the lowest similarity to references, and the cus and ars operons appear to be unique among Xanthomonads. Overall, the similarity of HMR genes to Stenotrophomonas sp. chromosomal genomes suggest their origin in this genus or a related organism and subsequent spread through lateral gene transfer events. Further resistome characterization revealed the presence of small multidrug resistance (SMR), multidrug resistance (MDR) efflux pumps, and bla (Xcc) genes for broad biocide resistance in both species. Concurrently, resistance to antibiotics (streptomycin, kanamycin, tetracycline, chloramphenicol, and ampicillin) up to 1000 µg/mL was confirmed.


Asunto(s)
Antibacterianos , Metales Pesados , Animales , Humanos , Antibacterianos/farmacología , Cobre , Metales Pesados/toxicidad , Ampicilina , Cloranfenicol
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA