Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.788
Filtrar
1.
Sci Total Environ ; 947: 174521, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38972414

RESUMEN

Chlorination is the most widely used disinfection technology due to its simplicity and continuous disinfection ability. However, the drawbacks of disinfection by-products and chlorine-resistant bacteria have gained increasing attention. Nowadays, ferrate (Fe(VI)) is a multifunctional and environmentally friendly agent which has great potential in wastewater reclamation and reuse. This study investigated synergistic Fe(VI) and chlorine technology for reclaimed water disinfection in terms of microbial control and chlorine decay mitigation. Specifically, synergistic disinfection significantly improved the inactivation efficiency on total coliform, Escherichia coli and heterotrophic bacteria compared to sole chlorination. Synergistic disinfection also exhibited superior performance on controlling the relative abundance of chlorine-resistant bacteria and pathogenic bacteria. In addition, the decay rate of residual chlorine was relatively lower after Fe(VI) pretreatment, which was beneficial for microbial control during the reclaimed water distribution process. Technical and economic analyses revealed that synergistic Fe(VI) and chlorine disinfection was suitable and feasible. Results of this study are believed to provide useful information and alternative options on the optimization of reclaimed water disinfection.


Asunto(s)
Cloro , Desinfección , Hierro , Eliminación de Residuos Líquidos , Purificación del Agua , Cloro/farmacología , Desinfección/métodos , Purificación del Agua/métodos , Eliminación de Residuos Líquidos/métodos , Desinfectantes/farmacología , Aguas Residuales/microbiología , Escherichia coli/efectos de los fármacos , Microbiología del Agua
2.
Bull Exp Biol Med ; 177(1): 98-103, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38963599

RESUMEN

We examined the effects of elevated temperatures and biocides on survivability of food isolates of Cronobacter spp. (C. sakazakii) and concomitant enterobacteriaceae obtained in microbiological control of infant nutrition products. Increased resistance of certain strains of Cronobacter, Enterobacter cloacae, and Pantoea spp. to thermal processing was revealed. Salmonella, Pantoea, and Cronobacter bacteria were least sensitive to antimicrobial action of chlorine-containing agents. The above properties varied in the strains of the same species. Specifically, only two of three examined isolates of Cronobacter spp. demonstrated lower sensitivity to heat in comparison with the enterobacterial test-cultures of other species.


Asunto(s)
Cloro , Cronobacter , Desinfectantes , Microbiología de Alimentos , Desinfectantes/farmacología , Cronobacter/efectos de los fármacos , Cronobacter/aislamiento & purificación , Cloro/farmacología , Enterobacteriaceae/efectos de los fármacos , Enterobacteriaceae/aislamiento & purificación , Calor , Humanos , Cronobacter sakazakii/efectos de los fármacos , Cronobacter sakazakii/aislamiento & purificación , Pruebas de Sensibilidad Microbiana , Salmonella/efectos de los fármacos , Salmonella/aislamiento & purificación , Enterobacter cloacae/efectos de los fármacos , Enterobacter cloacae/aislamiento & purificación
3.
Water Res ; 261: 122011, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38959654

RESUMEN

The presence of "viable but nonculturable" (VBNC) state and bacterial antibiotic resistance (BAR) both pose significant threats to the safety of drinking water. However, limited data was available that explicitly addressed the contribution of bacterial VBNC state in the maintenance and propagation of BAR. Here, the VBNC state induction and resuscitation of two antibiotic-resistant Escherichia coli K12 strains, one carrying multidrug-resistant plasmid (RP4 E. coli) and the other with chromosomal mutation (RIF E. coli) were characterized by subjecting them to different doses of UV/chlorine. The results illustrated that the induction, resuscitation, and associated mechanisms of VBNC ARB exhibit variations based on resistance determinants. RP4 E. coli exhibited a higher susceptibility to enter VBNC state compared to the RIF E. coli., and most VBNC state and resuscitated RP4 E. coli retained original antibiotic resistance. While, reverse mutation in the rpoB gene was observed in VBNC state and recovered RIF E. coli strains induced by high doses of UV/chlorine treatment, leading to the loss of rifampicin resistance. According to RT-qPCR results, ARGs conferring efflux pumps appeared to play a more significant role in the VBNC state formation of RP4 E. coli and the down-regulation of rpoS gene enhanced the speed at which this plasmid-carrying ARB entered into the dormant state. As to RIF E. coli, the induction of VBNC state was supposed to be regulated by the combination of general stress response, SOS response, stringent response, and TA system. Above all, this study highlights that ARB could become VBNC state during UV/chlorine treatments and retain, in some cases, their ability to spread ARGs. Importantly, compared with chromosomal mutation-mediated ARB, both VBNC and resuscitated state ARB that carries multidrug-resistant plasmids poses more serious health risks. Our study provides insights into the relationship between the VBNC state and the propagation of BAR in drinking water systems.


Asunto(s)
Cloro , Escherichia coli , Rayos Ultravioleta , Escherichia coli/efectos de los fármacos , Escherichia coli/genética , Cloro/farmacología , Antibacterianos/farmacología , Farmacorresistencia Bacteriana/genética , Plásmidos , Proteínas de Escherichia coli/genética , Mutación , Viabilidad Microbiana
4.
Environ Sci Pollut Res Int ; 31(35): 48073-48084, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39017868

RESUMEN

Recent advancements in membrane technologies and disinfection methods have enhanced drinking water quality significantly. However, microorganisms, including free-living amoebae (FLA), persist and pose potential threats to humans. FLA are linked to severe neuro-ophthalmic infections and serve as hosts of pathogenic bacteria. This study examined FLA presence in chlorinated and ultrafiltration drinking water and evaluated chlorine's disinfectant. Of 115 water samples, 21 tested positive for Acanthamoeba sp., Allovahlkampfia sp., and Vermamoeba vermiformis, originating from chlorinated sources. FLA trophozoites withstand temperatures up to 37 °C, while the cysts tolerate heat shocks of 60-70 °C. Trophozoites are susceptible to 5 mg L-1 chlorine, but cysts remain viable at concentrations up to 10 mg L-1. FLAs' survival in chlorinated waters is attributed to high cyst tolerance and lower residual chlorine concentrations. These findings highlight the need for ultrafiltration or enhanced chlorination protocols to ensure safer drinking water.


Asunto(s)
Amoeba , Agua Potable , Halogenación , Amoeba/efectos de los fármacos , Agua Potable/química , Cloro/farmacología , Desinfección/métodos , Desinfectantes , Purificación del Agua/métodos
5.
J Food Prot ; 87(8): 100314, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38876365

RESUMEN

The efficacy of a sanitizer in biofilm removal may be influenced by a combination of factors such as sanitizer exposure time and concentration, bacterial species, surface topography, and shear stresses. We employed an inline biofilm reactor to investigate the interactions of these variables on biofilm removal with chlorine. The CDC bioreactor was used to grow E. coli O157:H7 and L. monocytogenes biofilms as a single species or with Ralstonia insidiosa as a dual-species biofilm on stainless steel, PTFE, and EPDM coupons at shear stresses 0.368 and 2.462 N/m2 for 48 hours. Coupons were retrieved from a CDC bioreactor and placed in an inline biofilm reactor and 100, 200, or 500 ppm of chlorine was supplied for 1- and 4 min. Bacterial populations in the biofilms were quantified pre- and posttreatment by plating on selective media. After chlorine treatment, reduction (Log CFU/cm2) in pathogen populations obtained from three replicates was analyzed for statistical significance. A 1-min chlorine treatment (500 ppm), on dual-species E. coli O157:H7 biofilms grown at high shear stress of 2.462 N/m2 resulted in significant E. coli O157:H7 reductions on SS 316L (2.79 log CFU/cm2) and PTFE (1.76 log CFU/cm2). Similar trend was also observed for biofilm removal after a 4-min chlorine treatment. Single species E. coli O157:H7 biofilms exhibited higher resistance to chlorine when biofilms were developed at high shear stress. The effect of chlorine in L. monocytogenes removal from dual-species biofilms was dependent primarily on the shear stress at which they were formed rather than the surface topography of materials. Besides surface topography, shear stresses at which biofilms were formed also influenced the effect of sanitizer. The removal of E. coli O157:H7 biofilms from EPDM material may require critical interventions due to difficulty in removing this pathogen. The inline biofilm reactor is a novel tool to evaluate the efficacy of a sanitizer in bacterial biofilm removal.


Asunto(s)
Biopelículas , Recuento de Colonia Microbiana , Desinfectantes , Escherichia coli O157 , Listeria monocytogenes , Escherichia coli O157/efectos de los fármacos , Biopelículas/efectos de los fármacos , Listeria monocytogenes/efectos de los fármacos , Desinfectantes/farmacología , Cloro/farmacología , Microbiología de Alimentos , Reactores Biológicos , Relación Dosis-Respuesta a Droga , Humanos , Contaminación de Alimentos/prevención & control , Factores de Tiempo , Acero Inoxidable
6.
Environ Sci Technol ; 58(27): 12260-12271, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38923944

RESUMEN

Despite the critical importance of virus disinfection by chlorine, our fundamental understanding of the relative susceptibility of different viruses to chlorine and robust quantitative relationships between virus disinfection rate constants and environmental parameters remains limited. We conducted a systematic review of virus inactivation by free chlorine and used the resulting data set to develop a linear mixed model that estimates chlorine inactivation rate constants for viruses based on experimental conditions. 570 data points were collected in our systematic review, representing 82 viruses over a broad range of environmental conditions. The harmonized inactivation rate constants under reference conditions (pH = 7.53, T = 20 °C, [Cl-] < 50 mM) spanned 5 orders of magnitude, ranging from 0.0196 to 1150 L mg-1 min-1, and uncovered important trends between viruses. Whereas common surrogate bacteriophage MS2 does not serve as a conservative chlorine disinfection surrogate for many human viruses, CVB5 was one of the most resistant viruses in the data set. The model quantifies the role of pH, temperature, and chloride levels across viruses, and an online tool allows users to estimate rate constants for viruses and conditions of interest. Results from the model identified potential shortcomings in current U.S. EPA drinking water disinfection requirements.


Asunto(s)
Cloro , Desinfección , Cloro/farmacología , Inactivación de Virus/efectos de los fármacos , Virus/efectos de los fármacos , Desinfectantes/farmacología
7.
Water Res ; 260: 121932, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38906077

RESUMEN

Disinfection efficiency and disinfection byproduct (DBP) formation are two important aspects deserving careful consideration when evaluating different disinfection protocols. However, most of the previous studies on the selection of disinfection methods by comparing DBP formation were carried out under the same initial/residual dose and contact time of different disinfectants, and such a practice may cause overdose or underdose of a certain disinfectant, leading to the inaccurate evaluation of disinfection. In this study, a comprehensive and quantitative comparison of chlorine (Cl2) and chlorine dioxide (ClO2) disinfection was conducted with regard to their DBP formation under equal disinfection efficiency. The microbial inactivation models as well as the Cl2 and ClO2 demand models were developed. On such basis, the integral CT (ICT) values were determined and used as a bridge to connect disinfection efficiency and DBP formation. For 3-log10 and 4-log10 reductions of Pseudomonas aeruginosa, ClO2 had 1.5 and 5.8 times higher inactivation ability than Cl2, respectively. In the premise of equal disinfection efficiency (i.e., the ICT ratios of Cl2 to ClO2 = 1.5 and 5.8), the levels of total organic chlorine, total organic bromine, and total organic halogen formed in the Cl2 disinfection were significantly higher than those formed in the ClO2 disinfection. Among the 35 target aliphatic DBPs, trihalomethanes (THMs) and haloacetic acids (HAAs) were the dominant species formed in both Cl2 and ClO2 disinfection. The total THM levels formed in Cl2 disinfection were 14.6 and 30.3 times higher than those in ClO2 disinfection, respectively. The total HAA levels formed in Cl2 disinfection were 3.5 and 5.4 times higher than those in ClO2 disinfection, respectively. Formation of the target 48 aromatic DBPs was much favored in Cl2 disinfection than that in ClO2 disinfection, and the formation levels was dominated by contact time. This study demonstrated that ClO2 had significant advantages over Cl2, especially at higher microorganism inactivation and lower DBP formation requirements.


Asunto(s)
Compuestos de Cloro , Cloro , Desinfectantes , Desinfección , Agua Potable , Óxidos , Purificación del Agua , Compuestos de Cloro/farmacología , Compuestos de Cloro/química , Óxidos/farmacología , Óxidos/química , Cloro/farmacología , Cloro/química , Desinfección/métodos , Desinfectantes/farmacología , Desinfectantes/química , Agua Potable/microbiología , Agua Potable/química , Pseudomonas aeruginosa/efectos de los fármacos
8.
J Hazard Mater ; 474: 134697, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38823102

RESUMEN

Airborne pathogens severely threaten public health worldwide. Air disinfection is essential to ensure public health. However, excessive use of disinfectants may endanger environmental and ecological security due to the residual disinfectants and their by-products. This study systematically evaluated disinfection efficiency, induction of multidrug resistance, and the underlying mechanisms of disinfectants (NaClO and H2O2) on airborne bacteria. The results showed that airborne bacteria were effectively inactivated by atomized NaClO (>160 µg/L) and H2O2 (>320 µg/L) after 15 min. However, some bacteria still survived after disinfection by atomized NaClO (0-80 µg/L) and H2O2 (0-160 µg/L), and they exhibited significant increases in antibiotic resistance. The whole-genome sequencing of the resistant bacteria revealed distinct mutations that were responsible for both antibiotic resistance and virulence. This study also provided evidences and insights into possible mechanisms underlying the induction of antibiotic resistance by air disinfection, which involved intracellular reactive oxygen species formation, oxidative stress responses, alterations in bacterial membranes, activation of efflux pumps, and the thickening of biofilms. The present results also shed light on the role of air disinfection in inducing antibiotic resistance, which could be a crucial factor contributing to the global spread of antibiotic resistance through the air.


Asunto(s)
Bacterias , Desinfectantes , Desinfección , Peróxido de Hidrógeno , Peróxido de Hidrógeno/farmacología , Desinfectantes/farmacología , Desinfección/métodos , Bacterias/efectos de los fármacos , Bacterias/genética , Microbiología del Aire , Biopelículas/efectos de los fármacos , Hipoclorito de Sodio/farmacología , Farmacorresistencia Bacteriana/genética , Farmacorresistencia Bacteriana/efectos de los fármacos , Antibacterianos/farmacología , Cloro/farmacología , Especies Reactivas de Oxígeno/metabolismo
9.
Am J Vet Res ; 85(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38942065

RESUMEN

OBJECTIVE: The disinfection efficiency of disinfectants differs in specific conditions. This study aimed to investigate the disinfection efficiency of commercial hydrogen peroxide, chlorine dioxide, and chlorine disinfectant on real field surfaces and provide data for precise disinfection. METHODS: Simulated field disinfection and field disinfection methods were conducted to quantitatively evaluate the disinfection efficiency of hydrogen peroxide, chlorine dioxide, and sodium dichloroisocyanurate. The log10 reduction of biological indicators, Escherichia coli (ATCC 8099) and Staphylococcus aureus (ATCC 6538), was calculated. Next, the reduction in natural bacteria on the surfaces of a food production and processing workshop and a biosafety laboratory was determined. RESULTS: The 3 commercial disinfectants evaluated were effective against E coli and S aureus, with a reduction of more than 3.00 log10 colony-forming units/mL tested for an exposure time of 15 minutes with 3.5% hydrogen peroxide, 100 mg/L chlorine dioxide, and 250 mg/L sodium dichloroisocyanurate. The natural load in the food production and processing workshop decreased by more than 90% using 10.5% hydrogen peroxide with an exposure time of 30 minutes. The same disinfection level in the biosafety level 2 laboratory was achieved by 500 mg/L chlorine dioxide at an exposure time of 60 minutes and 450 mg/L sodium dichloroisocyanurate at 60 minutes. CLINICAL RELEVANCE: This study provides a reference for precise disinfection of surfaces in the food industry and biosafety laboratories.


Asunto(s)
Compuestos de Cloro , Desinfectantes , Desinfección , Escherichia coli , Peróxido de Hidrógeno , Óxidos , Staphylococcus aureus , Compuestos de Cloro/farmacología , Óxidos/farmacología , Desinfectantes/farmacología , Peróxido de Hidrógeno/farmacología , Desinfección/métodos , Staphylococcus aureus/efectos de los fármacos , Escherichia coli/efectos de los fármacos , Triazinas/farmacología , Cloro/farmacología
10.
Arch Microbiol ; 206(7): 295, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38856934

RESUMEN

Microbial community biofilm exists in the household drinking water system and would pose threat to water quality. This paper explored biofilm formation and chlorination resistance of ten dual-species biofilms in three typical household pipes (stainless steel (SS), polypropylene random (PPR), and copper), and investigated the role of interspecific interaction. Biofilm biomass was lowest in copper pipes and highest in PPR pipes. A synergistic or neutralistic relationship between bacteria was evident in most biofilms formed in SS pipes, whereas four groups displayed a competitive relationship in biofilms formed in copper pipe. Chlorine resistance of biofilms was better in SS pipes and worse in copper pipes. It may be helped by interspecific relationships, but was more dependent on bacteria and resistance mechanisms such as more stable extracellular polymeric substance. The corrosion sites may also protect bacteria from chlorination. The findings provide useful insights for microbial control strategies in household drinking water systems.


Asunto(s)
Bacterias , Biopelículas , Cloro , Agua Potable , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Cloro/farmacología , Bacterias/efectos de los fármacos , Bacterias/genética , Bacterias/aislamiento & purificación , Bacterias/clasificación , Agua Potable/microbiología , Cobre/farmacología , Microbiología del Agua , Acero Inoxidable , Polipropilenos , Abastecimiento de Agua , Halogenación , Corrosión , Desinfectantes/farmacología
11.
Environ Pollut ; 356: 124331, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38848962

RESUMEN

The presence of both chlorine-resistant bacteria (CRB) and microplastics (MPs) in drinking water distribution systems (DWDS) poses a threat to water quality and human health. However, the risk of CRB bio evolution under the stress of MPs remains unclear. In this study, polypropylene (PP) and polyethylene (PE) were selected to study the adsorption and desorption behavior of sulfamethoxazole (SMX), and it was clear that MPs had the risk of carrying pollutants into DWDS and releasing them. The results of the antibiotic susceptibility test and disinfection experiment confirmed that MPs could enhance the resistance of CRB to antibiotics and disinfectants. Bacteria epigenetic resistance mechanisms were approached from multiple perspectives, including physiological and biochemical characteristics, as well as molecular regulatory networks. When MPs enter DWDS, CRB could attach to the surface of MPs and directly interact with both MPs and the antibiotics they release. This attachment process promoted changes in the composition and content of extracellular polymers (EPS) within cells, enhanced surface hydrophobicity, stimulated oxidative stress function, and notably elevated the relative abundance of certain antibiotic resistance genes (ARGs). This study elucidates the mechanism by which MPs alter the intrinsic properties of CRB, providing valuable insights into the effective avoidance of biological risks to water quality during CRB evolution.


Asunto(s)
Bacterias , Cloro , Agua Potable , Microplásticos , Microplásticos/toxicidad , Agua Potable/química , Agua Potable/microbiología , Bacterias/efectos de los fármacos , Bacterias/genética , Cloro/farmacología , Contaminantes Químicos del Agua , Antibacterianos/farmacología , Sulfametoxazol/farmacología
12.
Environ Pollut ; 356: 124364, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38878811

RESUMEN

The widespread use of chlorine-based disinfectants in drinking water treatment has led to the proliferation of chlorine-resistant bacteria and the risk of disinfection byproducts (DBPs), posing a serious threat to public health. This study aims to explore the effectiveness and potential applications of epigallocatechin gallate (EGCG) against chlorine-resistant Bacillus and its spores in water, providing new insights for the control of chlorine-resistant bacteria and improving the biological stability of distribution systems. The inactivation effects of EGCG on Bacillus subtilis (B. subtilis) and its spores were investigated using transmission electron microscopy, ATP measurement, and transcriptome sequencing analysis to determine changes in surface structure, energy metabolism, and gene expression levels, thereby elucidating the inactivation mechanism. The results demonstrate the potential application of EGCG in continuously inhibiting chlorine-resistant B. subtilis in water, effectively improving the biological stability of the distribution system. However, EGCG is not suitable for treating raw water with high spore content and is more suitable as a supplementary disinfectant for processes with strong spore removal capabilities, such as ozone, ultraviolet, or ultrafiltration. EGCG exhibits a disruptive effect on the morphological structure and energy metabolism of B. subtilis and suppresses the synthesis of substances, energy metabolism, and normal operation of the antioxidant system by inhibiting the expression of multiple genes, thereby achieving the inactivation of B. subtilis.


Asunto(s)
Bacillus subtilis , Catequina , Desinfectantes , Desinfección , Esporas Bacterianas , Bacillus subtilis/efectos de los fármacos , Desinfectantes/farmacología , Catequina/análogos & derivados , Catequina/farmacología , Esporas Bacterianas/efectos de los fármacos , Desinfección/métodos , Purificación del Agua/métodos , Cloro/farmacología
13.
Water Res ; 259: 121794, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824796

RESUMEN

Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.


Asunto(s)
Cloro , Desinfectantes , Legionella , Purificación del Agua , Cloraminas/farmacología , Cloro/farmacología , Compuestos de Cloro/farmacología , Desinfectantes/farmacología , Desinfección/métodos , Legionella/efectos de los fármacos , Óxidos/farmacología , Microbiología del Agua , Purificación del Agua/métodos , Abastecimiento de Agua
14.
J Hazard Mater ; 476: 134883, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-38897118

RESUMEN

Parabens are emerging contaminants that have been detected in drinking water. Their presence in DW distribution systems (DWDS) can alter bacterial behaviour, characteristics, and structure, which may compromise DW disinfection. This work provides insights into the impact of methylparaben (MP) on the tolerance to chlorine disinfection and antibiotics from dual-species biofilms formed by Acinetobacter calcoaceticus and Stenotrophomonas maltophilia isolated from DW and grown on high-density polyethylene (HDPE) and polypropylene (PPL). Results showed that dual-species biofilms grown on PPL were more tolerant to chlorine disinfection, expressing a decrease of over 50 % in logarithmic reduction values of culturable cells in relation to non-exposed biofilms. However, bacterial tolerance to antibiotics was not affected by MP presence. Although MP-exposed dual-species biofilms grown on HDPE and PPL were metabolically more active than non-exposed counterparts, HDPE seems to be the material with lower impact on DW risk management and disinfection, if MP is present. Overall, results suggest that MP presence in DW may compromise chlorine disinfection, and consequently affect DW quality and stability, raising potential public health issues.


Asunto(s)
Biopelículas , Cloro , Desinfectantes , Desinfección , Parabenos , Biopelículas/efectos de los fármacos , Parabenos/toxicidad , Cloro/farmacología , Desinfección/métodos , Desinfectantes/farmacología , Desinfectantes/toxicidad , Acinetobacter calcoaceticus/efectos de los fármacos , Stenotrophomonas maltophilia/efectos de los fármacos , Polipropilenos , Polietileno , Antibacterianos/farmacología , Antibacterianos/toxicidad , Purificación del Agua/métodos , Contaminantes Químicos del Agua/toxicidad
15.
Food Microbiol ; 122: 104552, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38839232

RESUMEN

In this study, we investigated the combined effect of 222 nm krypton-chlorine excilamp (EX) and 307 nm ultraviolet-B (UVB) light on the inactivation of Salmonella Typhimurium and Listeria monocytogenes on sliced cheese. The data confirmed that simultaneous exposure to EX and UVB irradiation for 80 s reduced S. Typhimurium and L. monocytogenes population by 3.50 and 3.20 log CFU/g, respectively, on sliced cheese. The synergistic cell count reductions in S. Typhimurium and L. monocytogenes in the combined treatment group were 0.88 and 0.59 log units, respectively. The inactivation mechanism underlying the EX and UVB combination treatment was evaluated using fluorescent staining. The combination of EX and UVB light induced the inactivation of reactive oxygen species (ROS) defense enzymes (superoxide dismutase) and synergistic ROS generation, resulting in synergistic lipid peroxidation and destruction of the cell membrane. There were no significant (P > 0.05) differences in the color, texture, or sensory attributes of sliced cheese between the combination treatment and control groups. These results demonstrate that combined treatment with EX and UVB light is a potential alternative strategy for inactivating foodborne pathogens in dairy products without affecting their quality.


Asunto(s)
Queso , Cloro , Listeria monocytogenes , Especies Reactivas de Oxígeno , Salmonella typhimurium , Rayos Ultravioleta , Queso/microbiología , Queso/análisis , Listeria monocytogenes/efectos de la radiación , Listeria monocytogenes/crecimiento & desarrollo , Listeria monocytogenes/efectos de los fármacos , Salmonella typhimurium/efectos de la radiación , Salmonella typhimurium/crecimiento & desarrollo , Salmonella typhimurium/efectos de los fármacos , Especies Reactivas de Oxígeno/metabolismo , Cloro/farmacología , Irradiación de Alimentos/métodos , Microbiología de Alimentos , Viabilidad Microbiana/efectos de la radiación , Recuento de Colonia Microbiana
16.
J Microorg Control ; 29(2): 75-80, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38880619

RESUMEN

When a hypochlorite solution is ultrasonically fogged in a room, free chlorine, i.e., HOCl and OCl-, reaches various positions in two forms: fine fog droplets and gaseous hypochlorous acid(HOCl(g)). In this study, the cumulative amount of free chlorine reaching various positions on the floor away from the fogger was measured in a 90-m3 room, using a sulfamate-carrying glass-fiber filter indicator. The fine droplets were blown out from the fogger into the spaces at different discharge port angles of 30 - 90°. Free chlorine was successfully trapped by sulfamate, forming monochlorosulfamate, which was stably retained on the indicator. The cumulative amount of free chlorine( ng/indicator) increased with fogging time at each position and depended on the blow angle and distance from the fogger. Minor differences in the HOCl(g) concentration near the floor at all positions were observed. The disinfection efficacy of the fogging treatment against Staphylococcus aureus on wet surfaces was relatively higher at positions near the fogger and lower at positions far from the fogger. At each discharge port angle, a strong correlation between the logarithmic reduction in relative viable cells and the cumulative amount of free chlorine reaching S. aureus plates was observed. The slopes of the regression lines of correlation diagrams as a function of the cumulative amount of free chlorine were between -0.0362 and -0.0413 ng-1. This study demonstrated that the cumulative amount of free chlorine measured using the filter indicator could reflect the sum of the free chlorine of both fine droplets and HOCl(g), and that the disinfection efficiency depended on the cumulative amount of free chlorine reaching different areas.


Asunto(s)
Cloro , Desinfectantes , Desinfección , Ácido Hipocloroso , Staphylococcus aureus , Cloro/farmacología , Cloro/química , Desinfección/métodos , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo , Ácido Hipocloroso/farmacología , Ácido Hipocloroso/química , Desinfectantes/farmacología , Desinfectantes/química , Ultrasonido
17.
J Hazard Mater ; 474: 134751, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38820748

RESUMEN

Chlorination on microplastic (MP) biofilms was comprehensively investigated with respect to disinfection efficiency, morphology, and core microbiome. The experiments were performed under various conditions: i) MP particles; polypropylene (PP) and polystyrene (PS), ii) MP biofilms; Escherichia coli for single-species and river water microorganisms for multiple-species, iii) different chlorine concentrations, and iv) different chlorine exposure periods. As a result, chlorination effectively inactivated the MP biofilm microorganisms. The disinfection efficiency increased with increasing the free chlorination concentration and exposure periods for both single- and multiple-species MP biofilms. The multiple-species MP biofilms were inactivated 1.3-6.0 times less than single-species MP biofilms. In addition, the PP-MP biofilms were more vulnerable to chlorination than the PS-MP biofilms. Morphology analysis verified that chlorination detached most MP biofilms, while a small part still remained. Interestingly, chlorination strongly changed the biofilm microbiome on MPs; the relative abundance of some microbes increased after the chlorination, suggesting they could be regarded as chlorine-resistant bacteria. Some potential pathogens were also remained on the MP particles after the chlorination. Notably, chlorination was effective in inactivating the MP biofilms. Further research should be performed to evaluate the impacts of residual MP biofilms on the environment.


Asunto(s)
Biopelículas , Cloro , Desinfección , Escherichia coli , Halogenación , Microplásticos , Biopelículas/efectos de los fármacos , Desinfección/métodos , Cloro/farmacología , Cloro/química , Escherichia coli/efectos de los fármacos , Microplásticos/toxicidad , Microbiología del Agua , Desinfectantes/farmacología , Polipropilenos/química , Poliestirenos/química , Purificación del Agua/métodos
18.
Sci Total Environ ; 934: 173210, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750753

RESUMEN

Controlling the dissemination of antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) is a global concern. While commonly used chlorine disinfectants can damage or even kill ARB, dissolved oxygen (DO) may affect the formation of reactive chlorine species. This leads to the hypothesis that DO may play roles in mediating the effectiveness of chlorine disinfection for antibiotic resistance. To this end, this study investigated the impacts of DO on the efficiency of chlorine disinfection for antibiotic resistance. The results revealed that DO could increase the inactivation efficiency of ARB under chloramine and free chlorine exposure at practically relevant concentrations. Reactive species induced by DO, including H2O2, O2-, and OH, inactivated ARB strains by triggering oxidative stress response and cell membrane damage. In addition, the removal efficiency of extracellular ARGs (i.e. tetA and blaTEM) was enhanced with increasing dosage of free chlorine or chloramine under aerobic conditions. DO facilitated the fragmentation of plasmids, contributing to the degradation of extracellular ARGs under exposure to chlorine disinfectants. The findings suggested that DO facilitates disinfection efficiency for antibiotic resistance in water treatment systems.


Asunto(s)
Cloro , Desinfectantes , Desinfección , Oxígeno , Cloro/farmacología , Desinfección/métodos , Desinfectantes/farmacología , Purificación del Agua/métodos , Farmacorresistencia Microbiana/genética , Farmacorresistencia Bacteriana/genética , Antibacterianos/farmacología
20.
Curr Microbiol ; 81(6): 141, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625380

RESUMEN

Legionella pneumophila can be transmitted to people, especially immunocompromised patients, via hospital water pipe systems and cause severe pneumonia. The aim of our study was to investigate the presence of major virulence factor genes, ability of biofilms formation, and correlation between presence of Legionella isolates and temperature, pH, and residual chlorine of water. Hundred water samples were collected from nine hospitals in Tehran, Iran. Temperature, pH, and residual chlorine were determined during sampling. Different virulence genes and the ability to form biofilms were subsequently analyzed among the L. pneumophila isolates. Results showed that 12 (12%) samples were positive in culture method and all of the isolates were positive as L. pneumophila species (mip). A correlation was found between Legionella culture positivity and temperature and pH of water, but there was no significant correlation between residual chlorine of water samples and the presence of Legionella. The isolation of Legionella rate in summer and spring was higher than winter and autumn. Twelve (100%) isolates were positive for mip genes, 9 (75%) for dot genes, 8 (66.66%) for hsp, 6 (50%) for lvh, and 4 (33.33%) for rtx. All of the isolates displayed strong ability for biofilm production every three days. Two of these isolates (16.6%) displayed weak ability to form biofilm on the first day of incubation. This study revealed that water sources in hospitals were colonized by virulent Legionella and should be continuously monitored to avoid elevated concentrations of Legionella with visible biofilm formation.


Asunto(s)
Legionella pneumophila , Legionella , Humanos , Legionella pneumophila/genética , Virulencia/genética , Cloro/farmacología , Irán , Biopelículas , Hospitales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA