Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 720
Filtrar
1.
Bull Hosp Jt Dis (2013) ; 82(3): 199-204, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39150874

RESUMEN

INTRODUCTION: Dual mobility acetabular systems for total hip arthroplasty (THA) have been shown to have decreased dislocation rates and reduced revision rates, but there is controversy over the potential release of sufficient levels of metal ions into the blood to cause adverse local tissue reactions. However, there is a lack of long-term studies analyzing these levels of cobalt and chromium. Therefore, the purpose of this study was to investigate the levels these metal ions at a minimum 5-year follow-up after dual mobility implantation. Specifically, we analyzed: 1. overall blood and urine cobalt levels; 2. overall blood and urine chromium levels; 3. cobalt levels stratified by length of follow-up and various implant-related metrics (i.e., offset, cup size, stem, and neck angle); as well as 4. chromium levels stratified by length of follow-up and these various implant-related metrics. METHODS: A total of 41 patients who underwent THA with modular dual mobility acetabular systems between January 1, 2011, and December 31, 2016, were identified and followed for a mean time of 6 years (range: 5 to 10 years). All patients had well-functioning hips (Harris Hip Scores greater than 90 points (range: 90 to 100 points) and had no evidence of impending radiographic failure or progressive radiolucencies. Cobalt and chromium serum and plasma, blood, as well as urine levels were obtained at final followup. Additional parameters analyzed included: head material and size, stem offset, cup size, as well as stem-neck angle. RESULTS: Concentrations of cobalt were low as the mean blood and urine levels for all patients were 0.6 ± 0.5 µg/L (normal < 1.8 µg/L) and 0.8 ± 0.8 µg/L (normal < 2.8 µg/L), respectively. Only one patient had a minimally elevated blood cobalt level by 0.1 µg/L. These levels were not substantially different when subgroup analyses were performed for ceramic and cobalt-chrome heads. The mean chromium levels in blood and urine were also found to be low for all patients as values were 0.8 ± 0.2 µg/L (normal: < 1.2 µg/L) and 1.2 ± 0.5 ng/milliliter (normal: < 2 ng/L), respectively. Similarly, only one patient had a very slightly elevated blood chromium level of 1.3 µg/L. Additionally, analyses of ceramic or cobalt-chrome heads separately did not demonstrate differences in blood or urine levels. Blood cobalt or chromium concentrations had minimal changes with longer lengths of follow-ups, and with different stem offsets, cup sizes, stems, or neck angles. CONCLUSION: Dual mobility acetabular systems when combined with the two stems studied produced low levels of blood as well as urine cobalt and chromium levels at a minimum follow-up of 5 years (mean: 6 years; range: 5 to 10 years). These results remained below the threshold of normal and clinically insignificant regardless of length of follow-up, head material, or various implant measurements. To the best of our knowledge, this is the first study to demonstrate low levels of metal ions at longer than 4-year follow-up. These data may be of importance to surgeons deciding on the appropriate implants to use for their high-risk patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cromo , Cobalto , Prótesis de Cadera , Diseño de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Cobalto/sangre , Cobalto/orina , Femenino , Masculino , Cromo/sangre , Cromo/orina , Persona de Mediana Edad , Anciano , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Estudios Retrospectivos , Adulto , Factores de Tiempo , Estudios de Seguimiento , Anciano de 80 o más Años , Resultado del Tratamiento
2.
Respir Res ; 25(1): 324, 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39182083

RESUMEN

BACKGROUND: Cobalt (Co) is a metal which is widely used in the industrial production. The previous studies found the toxic effects of environmental Co exposure on multiple organs. However, the correlation of blood Co concentration with lung function was inconsistent in patients with chronic obstructive pulmonary disease (COPD). METHODS: All 771 stable COPD patients were recruited. Peripheral blood and clinical information were collected. The levels of blood Co and serum CC16 were measured. RESULTS: Cross-sectional study suggested that the level of blood Co was inversely and dose-dependently related to lung function parameters. Each 1 ppm elevation of blood Co was related to 0.598 L decline in FVC, 0.465 L decline in FEV1, 6.540% decline in FEV1/FVC%, and 14.013% decline in FEV1%, respectively. Moreover, higher age, enrolled in winter, current-smoking, higher smoking amount, and inhaled corticosteroids prominently exacerbated the negative correlation between blood Co and lung function. Besides, serum CC16 content was gradually reduced with blood Co elevation in COPD patients. Besides, serum CC16 was positively correlated with lung function, and inversely related to blood Co. Additionally, decreased CC16 substantially mediated 11.45% and 6.37% Co-triggered downregulations in FEV1 and FEV1%, respectively. CONCLUSION: Blood Co elevation is closely related to the reductions of pulmonary function and serum CC16. CC16 exerts a significantly mediating role of Co-related to pulmonary function decrease among COPD patients.


Asunto(s)
Cobalto , Enfermedad Pulmonar Obstructiva Crónica , Uteroglobina , Humanos , Enfermedad Pulmonar Obstructiva Crónica/sangre , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Masculino , Uteroglobina/sangre , Femenino , Cobalto/sangre , Anciano , Persona de Mediana Edad , Estudios Transversales , Pulmón/efectos de los fármacos , Pulmón/fisiopatología , Pulmón/metabolismo , Volumen Espiratorio Forzado/fisiología , Pruebas de Función Respiratoria/métodos , Biomarcadores/sangre , Capacidad Vital/fisiología
3.
Artículo en Inglés | MEDLINE | ID: mdl-38851151

RESUMEN

In this study, a magnetic three-dimensional nano-composite based on Rubber-Fe3O4@Ni-Co Layered double hydroxide derived from ZIF-67 template was synthesized by a hydrothermal method. The proposed nano-composite was used as a sorbent for the enrichment of trace amounts of anti-cancer drugs (dasatinib and erlotinib hydrochloride) from plasma samples followed by determination using high-performance liquid chromatographic analysis (HPLC-UV). The synthesized nano-sorbent was characterized by X-ray diffraction, field emission scanning electron microscopy, Fourier transform infrared spectroscopy, vibrating-sample magnetometer, Brunauer-Emmett-Teller surface analysis, Barrett-Joyner-Halenda pore size analysis and energy dispersive X-ray spectroscopy. Under optimal experimental conditions, factors affecting on extraction efficiency such as pH, ionic strength, extraction temperature and time, desorption solvent and time, the limit of detection (LODs) and the limit of quantification (LOQs) were obtained as 0.6, 2 µg/L for both of dasatinib and erlotinib, respectively. Also, linear range of the method were 2-500 and 2-1000 µg/L for dasatinib and erlotinib, respectively. Relative standard deviations (RSD%) for the repeatability of extraction on sorbent to sorbent were obtained as 3.59, 1.97 %, and one sorbent reusability were investigated and relative standard deviation values were obtained 5.35, 3.30 % for dasatinib and erlotinib, respectively.


Asunto(s)
Antineoplásicos , Clorhidrato de Erlotinib , Límite de Detección , Goma , Goma/química , Antineoplásicos/sangre , Antineoplásicos/química , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados , Humanos , Clorhidrato de Erlotinib/sangre , Clorhidrato de Erlotinib/química , Modelos Lineales , Dasatinib/sangre , Dasatinib/química , Hidróxidos/química , Imidazoles/química , Imidazoles/sangre , Adsorción , Extracción en Fase Sólida/métodos , Cobalto/química , Cobalto/sangre , Nanoestructuras/química , Zeolitas
4.
J Expo Sci Environ Epidemiol ; 34(4): 688-698, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38698271

RESUMEN

BACKGROUND: Growing evidence suggests that cardiovascular disease develops over the lifetime, often beginning in childhood. Metal exposures have been associated with cardiovascular disease and important risk factors, including dyslipidemia, but prior studies have largely focused on adult populations and single metal exposures. OBJECTIVE: To investigate the individual and joint impacts of multiple metal exposures on lipid levels during childhood. METHODS: This cross-sectional study included 291 4-year-old children from the Rhea Cohort Study in Heraklion, Greece. Seven metals (manganese, cobalt, selenium, molybdenum, cadmium, mercury, and lead) were measured in whole blood using inductively coupled plasma mass spectrometry. Serum lipid levels included total cholesterol, triglycerides, high-density lipoprotein (HDL) cholesterol, and low-density lipoprotein (LDL) cholesterol. To determine the joint and individual impacts of child metal exposures (log2-transformed) on lipid levels, Bayesian kernel machine regression (BKMR) was employed as the primary multi-pollutant approach. Potential effect modification by child sex and childhood environmental tobacco smoke exposure was also evaluated. RESULTS: BKMR identified a positive association between the metal mixture and both total and LDL cholesterol. Of the seven metals examined, selenium (median 90.6 [IQR = 83.6, 96.5] µg/L) was assigned the highest posterior inclusion probability for both total and LDL cholesterol. A difference in LDL cholesterol of 8.22 mg/dL (95% CI = 1.85, 14.59) was observed when blood selenium was set to its 75th versus 25th percentile, holding all other metals at their median values. In stratified analyses, the positive association between selenium and LDL cholesterol was only observed among boys or among children exposed to environmental tobacco smoke during childhood. IMPACT STATEMENT: Growing evidence indicates that cardiovascular events in adulthood are the consequence of the lifelong atherosclerotic process that begins in childhood. Therefore, public health interventions targeting childhood cardiovascular risk factors may have a particularly profound impact on reducing the burden of cardiovascular disease. Although growing evidence supports that both essential and nonessential metals contribute to cardiovascular disease and risk factors, such as dyslipidemia, prior studies have mainly focused on single metal exposures in adult populations. To address this research gap, the current study investigated the joint impacts of multiple metal exposures on lipid concentrations in early childhood.


Asunto(s)
Exposición a Riesgos Ambientales , Metales , Humanos , Grecia/epidemiología , Femenino , Preescolar , Masculino , Estudios Transversales , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Metales/sangre , Estudios de Cohortes , Selenio/sangre , Lípidos/sangre , Teorema de Bayes , Contaminación por Humo de Tabaco/efectos adversos , Contaminantes Ambientales/sangre , Mercurio/sangre , LDL-Colesterol/sangre , Cobalto/sangre , Manganeso/sangre , Molibdeno/sangre , Cadmio/sangre , Metales Pesados/sangre , Triglicéridos/sangre , Plomo/sangre , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/etiología
5.
Clin Nutr ; 43(6): 1459-1472, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38714150

RESUMEN

BACKGROUND & AIMS: In this study, we assessed serum trace element concentrations in patients with pancreatic cancer and compared the results to those of healthy controls and patients with chronic pancreatitis. We evaluated the association between trace element concentrations during cancer treatment and the risk of cancer progression and mortality in pancreatic cancer patients. METHODS: A retrospective cohort study was conducted at a tertiary center in Korea. Serum trace element concentrations of cobalt (Co), copper (Cu), selenium (Se), and zinc (Zn) were measured at diagnosis using an inductively coupled plasma-mass spectrometry in 124 patients with pancreatic cancer, 50 patients with chronic pancreatitis, and 120 healthy controls. Trace elements were measured after a median of 282.5 (95% confidence interval [CI], 224.0-326.5) days from treatment initiation to assess changes in trace element concentrations during treatment. RESULTS: Serum Co concentrations were significantly higher in patients with chronic pancreatitis and pancreatic cancer compared to healthy controls, while serum Se concentrations were significantly lower. During treatment, serum concentrations of Cu, Se, and Zn significantly decreased in patients with pancreatic cancer. During the follow-up (median 152.5; 95% CI, 142.8-160.0 months), 85.5% of patients experienced progression or relapse, and 84.7% of patients died. Patients with decreased Se and Zn concentrations during treatment had a higher mortality (hazard ratio [HR], 2.10; 95% CI, 1.31-3.38; P = 0.0020 for Se; HR, 1.72; 95% CI, 1.06-2.79; P = 0.0269 for Zn) compared to those with unchanged or increased trace element concentrations during treatment. Patients with a greater reduction in Zn concentrations during treatment had a higher mortality than those with a smaller reduction (HR, 1.59; 95% CI, 1.01-2.52; P = 0.0483). Patients whose Zn status changed from normal to deficient during treatment had an increased mortality (HR, 1.76; 95% CI, 1.16-2.67, P = 0.0084). Patients with multiple (≥2) trace element deficiencies after treatment had poorer outcomes than those with no or single trace element deficiency. CONCLUSIONS: This study revealed that decreases in Se and Zn concentrations during cancer treatment were associated with adverse outcomes in terms of cancer progression and mortality in patients with pancreatic cancer. Further prospective investigations are recommended.


Asunto(s)
Neoplasias Pancreáticas , Oligoelementos , Humanos , Neoplasias Pancreáticas/sangre , Neoplasias Pancreáticas/mortalidad , Masculino , Femenino , Oligoelementos/sangre , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Pronóstico , República de Corea/epidemiología , Pancreatitis Crónica/sangre , Pancreatitis Crónica/mortalidad , Selenio/sangre , Zinc/sangre , Progresión de la Enfermedad , Cobre/sangre , Cobalto/sangre
6.
J Arthroplasty ; 39(9): 2336-2340, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38640965

RESUMEN

BACKGROUND: Megaprostheses contain many more modular components than conventional total hip and knee arthroplasty, which may lead to higher serum levels of metal ions. The aim of this study was to determine serum concentrations of titanium, chromium, and cobalt ions in cancer patients after limb salvage surgery with a megaprosthesis. METHODS: A retrospective, descriptive cohort analysis consisting of patients who underwent cancer-related limb salvage surgery with a megaprosthesis at our hospital between 2010 and 2020 was conducted. Baseline and follow-up data were extracted from clinical and surgical records. Blood samples were prospectively obtained. Descriptive statistics were used for the analysis. RESULTS: A total of 71 patients underwent limb salvage surgery during the study period. Of these, 22 (10 women, 12 men) were included in the study. The mean age was 52 years (range, 21 to 80). Most cases (n = 16; 72.7%) involved the femur. Most patients (n = 14, 63.6%) underwent total knee megaprosthesis surgery. Implant revision surgery was required in 45% of cases (n = 10), with a mean interval of 4.32 years between the initial and revision surgeries. The mean follow-up time after revision surgery was 4.05 years. High levels of chromium were observed in 22.7% of patients (n = 5). High cobalt levels were found in 68.2% (n = 15) of patients, with toxic levels in 9.1% (n = 2). Titanium levels were high in 77.3% (n = 17) of cases and toxic in 22.7% (n = 5). Postoperative chemotherapy was significantly associated with titanium levels (P = .017). No correlation was observed between metal ion levels and time from primary or revision surgery or time from the first to revision surgery. CONCLUSIONS: This study shows that cancer-related limb salvage surgery with megaprosthesis is associated with metal ion levels that exceed established safe thresholds. Compared to conventional hip arthroplasty, a higher proportion of the patients in this cohort presented elevated levels of metal ions. LEVEL OF EVIDENCE: III.


Asunto(s)
Cromo , Cobalto , Recuperación del Miembro , Reoperación , Titanio , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Cobalto/sangre , Adulto , Titanio/sangre , Cromo/sangre , Reoperación/estadística & datos numéricos , Recuperación del Miembro/métodos , Anciano de 80 o más Años , Neoplasias/cirugía , Neoplasias/sangre , Adulto Joven , Prótesis de la Rodilla/efectos adversos
7.
Nutrients ; 16(8)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38674871

RESUMEN

This study continues the research in which we determined the concentration of aluminum in children receiving long-term parenteral nutrition (LPN). Since our results were interesting, we decided to assay arsenic (As) and cobalt (Co) in the collected material, which, like aluminum, constitute contamination in the mixtures used in parenteral nutrition. Excesses of these trace elements in the human body are highly toxic, and deficiencies, particularly in the case of Co, can lead to various complications. The aim of this study was to determine the impact of LPN in children on their serum levels of As and Co, as well as the excretion of these elements in urine, and to compare them with a control group of healthy children. The study group consisted of 83 children receiving home parenteral nutrition from two Polish centers, while the control group included 121 healthy children. In both groups, the levels of As and Co in serum and urine were measured. The elemental compositions of the samples were determined using inductively coupled plasma mass spectrometry (ICP-MS). It was demonstrated that the children receiving LPN did not have increased As exposure compared to the controls. Greater exposure compared to the control group was shown for Co. In conclusion, children receiving LPN are not exposed to As, and even though the concentrations of Co in serum and urine were higher in the LPN group than in the healthy controls, neither trace element poses a health threat to children requiring LPN.


Asunto(s)
Arsénico , Cobalto , Humanos , Cobalto/orina , Cobalto/sangre , Arsénico/orina , Arsénico/sangre , Arsénico/análisis , Femenino , Masculino , Niño , Preescolar , Lactante , Nutrición Parenteral , Polonia , Estudios de Casos y Controles , Nutrición Parenteral en el Domicilio , Oligoelementos/sangre , Oligoelementos/orina , Adolescente
8.
J Orthop Res ; 42(6): 1292-1302, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38235918

RESUMEN

Production of metal debris from implant wear and corrosion processes is now a well understood occurrence following hip arthroplasty. Evidence has shown that metal ions can enter the bloodstream and travel to distant organs including the brain, and in extreme cases, can induce sensorial and neurological diseases. Our objective was tosimultaneously analyze brain anatomy and physiology in patients with long-term and well-functioning implants. Included were subjects who had received total hip or hip resurfacing arthroplastywith an implantation time of a minimum of 7 years (n = 28) and age- and sex-matched controls (n = 32). Blood samples were obtained to measure ion concentrations of cobalt and chromium, and the Montreal Cognitive Assessment was performed. 3T MRI brain scans were completed with an MPRAGE sequence for ROI segmentation and multiecho gradient echo sequences to generate QSM and R2* maps. Mean QSM and R2* values were recorded for five deep brain and four middle and cortical brain structures on both hemispheres: pallidum, putamen, caudate, amygdala, hippocampus, anterior cingulate, inferior temporal, and cerebellum. No differences in QSM or R2* or cognition scores were found between both groups (p > 0.6654). No correlation was found between susceptibility and blood ion levels for cobalt or chromium in any region of the brain. No correlation was found between blood ion levels and cognition scores. Clinical significance: Results suggest that metal ions released by long-term and well-functioning implants do not affect brain integrity.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Encéfalo , Cromo , Cobalto , Prótesis de Cadera , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Persona de Mediana Edad , Encéfalo/diagnóstico por imagen , Anciano , Cromo/sangre , Cobalto/sangre , Adulto , Estudios de Casos y Controles
9.
Am J Health Syst Pharm ; 81(7): e159-e165, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38141216

RESUMEN

PURPOSE: Cobalt metallosis is a rare but dangerous complication of total joint arthroplasty resulting from deterioration of the joint leading to metal-on-metal friction and breakdown. Potential manifestations vary in severity and include dilated cardiomyopathy, thyroid dysfunction, cognitive disturbances, neuropathy, fatigue, and weakness. The therapeutic role of N-acetylcysteine in metallosis has been investigated due to its ability to chelate with heavy metal ions, such as cobalt and chromium. SUMMARY: Here we report the case of a 71-year-old female who presented with suspected metallosis diagnosed in the outpatient setting due to symptoms of significant weight loss and failure to thrive. This metallosis was secondary to the hardware breakdown of a left knee revision roughly 6 years previously. The patient was not a surgical candidate due to her poor nutrition status and was started on nasojejunal tube feeds along with N-acetylcysteine 600 mg by mouth twice daily for 45 days. The patient's serum cobalt levels decreased from 61.7 µg/L on admission to 16.2 µg/L prior to her undergoing proper revision of the left knee roughly 2 months after admission to the hospital. The patient tolerated treatment well and was able to be discharged the day after surgery, with no further complaints or complications. CONCLUSION: This case report contributes to the body of literature suggesting that administration of N-acetylcysteine can reduce serum cobalt concentrations, without notable adverse effects, in the context of prosthetic knee-associated metallosis.


Asunto(s)
Acetilcisteína , Cobalto , Anciano , Femenino , Humanos , Acetilcisteína/uso terapéutico , Cromo , Cobalto/sangre , Metales/efectos adversos
10.
Ecotoxicol Environ Saf ; 265: 115528, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37783110

RESUMEN

This research aimed to approach relationships between metal mixture in blood and kidney function, tumor necrosis factor alpha (TNF-α) by machine learning. Metals levels were measured by Inductively Couple Plasma Mass Spectrometry in blood from 421 participants. We applied K Nearest Neighbor (KNN), Naive Bayes classifier (NB), Support Vector Machines (SVM), random forest (RF), Gradient Boosting Decision Tree (GBDT), Categorical boosting (CatBoost), eXtreme Gradient Boosting (XGBoost), Whale Optimization-based XGBoost (WXGBoost) to identify the effect of plasma metals, TNF-α, and estimated glomerular filtration rate (eGFR by CKD-EPI equation). We conducted not only toxic metals, lead (Pb), arsenic (As), cadmium (Cd) but also included trace essential metals, selenium (Se), copper (Cu), zinc (Zn), cobalt (Co), to predict the interaction of TNF-α, TNF-α/white blood count, and eGFR. The high average TNF-α level group was observed among subjects with higher Pb, As, Cd, Cu, and Zn levels in blood. No associations were shown between the low and high TNF-α level group in blood Se and Co levels. Those with lower eGFR group had high Pb, As, Cd, Co, Cu, and Zn levels. The crucial predictor of TNF-α level in metals was blood Pb, and then Cd, As, Cu, Se, Zn and Co. The machine learning revealed that As was the major role among predictors of eGFR after feature selection. The levels of kidney function and TNF-α were modified by co-exposure metals. We were able to acquire highest accuracy of over 85% in the multi-metals exposure model. The higher Pb and Zn levels had strongest interaction with declined eGFR. In addition, As and Cd had synergistic with prediction model of TNF-α. We explored the potential of machine learning approaches for predicting health outcomes with multi-metal exposure. XGBoost model added SHAP could give an explicit explanation of individualized and precision risk prediction and insight of the interaction of key features in the multi-metal exposure.


Asunto(s)
Riñón , Metales Pesados , Oligoelementos , Factor de Necrosis Tumoral alfa , Humanos , Arsénico/sangre , Teorema de Bayes , Cadmio/sangre , Cobalto/sangre , Riñón/fisiología , Plomo/sangre , Metales Pesados/sangre , Selenio/sangre , Oligoelementos/sangre , Factor de Necrosis Tumoral alfa/metabolismo , Aprendizaje Automático
11.
BMC Geriatr ; 23(1): 72, 2023 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-36737686

RESUMEN

BACKGROUND: Chromium (Cr) and cobalt (Co) are the essential elements for producing metal implants, but might have potential health issues. The research on the correlation between metal implants and blood Cr and Co on a large population is still limited. METHODS: National Health and Nutrition Examination Survey (NHANES) is a program of studies designed to assess the health status of Americans began in the early 1960s. The study was based on the NHANES database from two data collection years (2015-2016 and 2017-2018). The exposure variable of this study was whether the participants had metal objects in the body or not. The outcome variables were blood concentrations of Cr and Co. Age, body mass index, sex, race/ethnicity, income to poverty ratio, tap water behavior, shellfish/fish/tuna/salmon eating habits, level of education, smoking behavior, marital status, blood hemoglobin, and data collection years were included as confounding variables. RESULTS: A total of 4412 participants, aged 40 years or older, were included in this analysis, consisting of the without metal objects group (n = 3150) and the metal objects group (n = 1262). Metal objects was positively correlated to the accumulation of blood Cr (ß = 0.072, 95% CI: 0.043-0.102, p < 0.001) and blood Co (ß = 0.079, 95% CI: 0.049-0.109, p < 0.001). However, the positive correlation of metal objects with blood Cr was only presented in women (ß = 0.112, 95% CI: 0.074-0.151, p < 0.001), but not in men. Meanwhile, the positive relationship between metal objects and blood Cr/Co was not observed in the Asian subgroup. CONCLUSIONS: Blood Cr and Co concentrations were statistically higher in people with metal objects, but with race and sex differences. LEVEL OF EVIDENCE: Level IV, cross-sectional study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Femenino , Humanos , Masculino , Cromo/sangre , Cobalto/sangre , Estudios Transversales , Metales , Encuestas Nutricionales , Adulto
12.
Environ Sci Pollut Res Int ; 30(17): 50402-50411, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36795209

RESUMEN

Heavy metal exposure has been reported to be correlated with lipid profile alteration and dyslipidemia. While the associations between serum cobalt (Co) with lipid profile levels and risk of dyslipidemia have not been explored in elderly population, and the underlying mechanisms remain unclear. All eligible 420 elderly people were recruited in three communities of Hefei City in this cross-sectional study. Peripheral blood samples and clinical information were collected. The level of serum Co was detected through ICP-MS. The biomarkers for systemic inflammation (TNF-α) and lipid peroxidation (8-iso-PGF2α) were measured with ELISA. Each 1-unit increase of serum Co was related with 0.513 mmol/L, 0.196 mmol/L, 0.571 mmol/L, and 0.303 g/L in TC, TG, LDL-C, and ApoB, respectively. Multivariate linear and logistic regression analyses indicated that the prevalence of elevated TC, elevated LDL-C, and elevated ApoB were gradually increased according to tertiles of serum Co concentration (all P trend < 0.001). The risk of dyslipidemia was positively correlated with serum Co (OR = 3.500; 95% CI 1.630 ~ 7.517). Moreover, the levels of TNF-α and 8-iso-PGF2α were gradually risen in parallel with elevating serum Co. The elevation of TNF-α and 8-iso-PGF2α partially mediated Co-caused elevation of TC and LDL-C. Environmental Co exposure is associated with elevated lipid profile levels and dyslipidemia risk among elderly population. Systemic inflammation and lipid peroxidation partially mediate the associations of serum Co with dyslipidemia.


Asunto(s)
Dislipidemias , Lípidos , Anciano , Humanos , Apolipoproteínas B , LDL-Colesterol , Cobalto/sangre , Estudios Transversales , Dislipidemias/epidemiología , Inflamación , Peroxidación de Lípido , Factor de Necrosis Tumoral alfa
14.
Front Public Health ; 10: 1039514, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36582368

RESUMEN

Background: Metal exposure affects human health. Current studies mainly focus on the individual health effect of metal exposure on hypertension (HTN), and the results remain controversial. Moreover, the studies assessing overall effect of metal mixtures on hypertension risk are limited. Methods: A cross-sectional study was conducted by recruiting 1,546 Chinese adults who attended routine medical check-ups at the Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen. The plasma levels of 13 metals were measured using inductively coupled plasma mass spectrometry. Multivariate logistic regression model, restricted cubic spline (RCS) model and the Bayesian Kernel Machine Regression (BKMR) model were applied to explore the single and combined effect of metals on the risk of HTN. Results: A total of 642 (41.5%) participants were diagnosed with HTN. In the logistic regression model, the adjusted odds ratios (ORs) were 0.71 (0.52, 0.97) for cobalt, 1.40 (1.04, 1.89) for calcium, 0.66 (0.48, 0.90), and 0.60 (0.43, 0.83) for aluminum in the second and third quartile, respectively. The RCS analysis showed a V-shaped or an inverse V-shaped dose-response relationship between metals (aluminum or calcium, respectively) and the risk of HTN (P for non-linearity was 0.017 or 0.009, respectively). However, no combined effect was found between metal mixture and the risk of hypertension. Conclusions: Plasma levels of cobalt, aluminum and calcium were found to be associated with the risk of HTN. Further studies are needed to confirm our findings and their potential mechanisms with prospective studies and experimental study designs.


Asunto(s)
Aluminio , Calcio , Cobalto , Hipertensión , Adulto , Humanos , Aluminio/sangre , Teorema de Bayes , Calcio/sangre , Cobalto/sangre , Estudios Transversales , Hipertensión/epidemiología , Estudios Prospectivos
15.
Bone Joint J ; 104-B(3): 376-385, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227095

RESUMEN

AIMS: This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. METHODS: A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life. RESULTS: No differences in mean age (69 years, 40 to 86), mean age adapted Charlson Comorbidity Index (3.1 (SD 1.4)), mean BMI (29.2 kg/m2 (SD 5.8)), or number of other implants were observed between groups. Significant improvements in outcome scores and pain levels were achieved for all groups, and there was no difference in quality of life (12-Item Short-Form Health Survey questionnaire (SF-12)). Mean cobalt and chromium ion levels were significantly higher for the GenuX versus the BPKS hinged TKA (GenuX vs BPKS: cobalt: 16.3 vs 9.4 µg/l; chromium: 9.5 vs 5.2 µg/l). The TiN-coated implants did not appear to confer improvement in the metal ion levels. Metal ion concentrations above 7 µg/l were detected in 81%(29/36) of GenuX patients versus 41% (11/27) in the BPKS group. No GenuX patients had normal levels under 2 µg/l, versus 22% of BPKS patients. No significant reduction in outcome scores was observed regardless of the metal ion levels, whereas higher work-related activity was correlated with higher chromium concentrations. CONCLUSION: Hinged TKA, using MoM hinges, resulted in critically high cobalt and chromium ion concentrations. The BPKS hinged TKA showed significantly lower metal ion concentrations compared with the GenuX TKA. No benefits were observed using TiN coating. The different weightbearing mechanics might influence the wear of the component materials. Higher workloads and physical activity could influence chromium levels. Cite this article: Bone Joint J 2022;104-B(3):376-385.


Asunto(s)
Cromo/sangre , Cobalto/sangre , Prótesis de la Rodilla/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
16.
Acta Med Okayama ; 76(1): 33-39, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35236996

RESUMEN

Trace elements selenium (Se) and cobalt (Co) are essential in the human body, and a correlation between Se and cardiac surgery has been suggested. We investigated the plasma concentrations of Se and Co during and after coronary artery bypass grafting (CABG) surgery under cardiopulmonary bypass (CPB). From December 2019 to January 2020, preoperative plasma samples from isolated first-time CABG patients (n=20; 10 males, 10 females) were prospectively collected post-anesthesia and before CPB (T1), 45 min after CPB started (T2), 90 min after CPB started (T3), and postoperative days 1 (T4), and day 4 (T5). The plasma concentrations of Se and Co were measured. The Se concentration was significantly decreased at T2 (105.24±4.08 vs. 68.56±2.42 µg/L, p<0.001) and T3 (105.24±4.08 vs. 80.41±3.40 µg/L, p<0.001). The Co concentration was significantly decreased at T4 (0.35±0.19 vs. 0.26±0.13 µg/L, p<0.01) and T5 (0.35±0.19 vs. 0.23±0.11 µg/L, p<0.001). Five patients developed atrial fibrillation (AF); there was no other operative mortality or major morbidity. This is the first report of alterations of plasma Se and Co concentrations during and after CABG surgery. Our results may indicate that Se supplementation before or during CABG and Co supplementation after CABG may become necessary for patients undergoing CABG.


Asunto(s)
Cobalto/sangre , Puente de Arteria Coronaria , Selenio/sangre , Oligoelementos/sangre , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
17.
Medicine (Baltimore) ; 101(2): e28568, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35029227

RESUMEN

ABSTRACT: Various heavy metal elements in the human body have been reported to be associated with dyslipidemia, hypertension, and diabetes. The role of cobalt in these conditions is unclear. The current study aimed to investigate the association of blood cobalt concentrations with dyslipidemia, hypertension, and diabetes.Using the data collected from the National Health and Nutrition Examination Survey (2015-2018), we performed logistic regression to explore the association of blood cobalt concentrations with total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), triglycerides, hypertension, and diabetes.A total of 6866 adults were included in this study. Participants with higher blood cobalt levels appeared to be older and have a lower body mass index and, were more likely to be female (P for trend < .05). After fully adjusting for demographic characteristics (Model 2), compared with the lowest quartile, the highest quartile of blood cobalt concentrations had lower odds ratios (ORs) for elevated TC [OR: 0.62, 95% confidential interval (CI): 0.53 to 0.72, P < .001], elevated LDL-C (OR: 0.65, 95% CI: 0.53-0.80, P < .001) and low HDL-C (OR: 0.81, 95% CI: 0.69-0.96, P = .013). The adjusted ORs for elevated TC, elevated LDL-C and low HDL-C were negatively correlated with increased blood cobalt concentrations (P for trend < .05). The adjusted ORs for hypertension and diabetes were not associated with blood cobalt concentrations (P > .05 and P for trend > .05).In conclusion, higher blood cobalt concentrations were associated with a lower risk of dyslipidemia. However, blood cobalt concentrations were not associated with the risk of hypertension or diabetes.


Asunto(s)
Cobalto/sangre , Diabetes Mellitus , Dislipidemias , Hipertensión , Adulto , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Estudios Transversales , Diabetes Mellitus/epidemiología , Dislipidemias/epidemiología , Femenino , Humanos , Hipertensión/epidemiología , Masculino , Encuestas Nutricionales , Factores de Riesgo , Triglicéridos/sangre , Estados Unidos/epidemiología
18.
Vopr Pitan ; 91(6): 92-101, 2022.
Artículo en Ruso | MEDLINE | ID: mdl-36648187

RESUMEN

Salts of inorganic cobalt (Со) prevent the degradation of the alpha subunit of the hypoxia-inducible factor (HIF), imitating the state of hypoxia in the body and increasing the production of the endogenous hormone erythropoietin (EPO), and are used as doping substances that increase blood oxygen capacity and endurance, which give competitive advantages in sports. Currently, a large number of dietary supplements, including Co-containing ones, are offered on free sale. Their uncontrolled intake can affect not only the professional career of athletes, but also their health, due to the fact that this trace element and its salts are the strongest inorganic poisons and carcinogens. Despite this, their availability on the pharmaceutical market, a noticeable effect of erythropoiesis stimulation and a convenient oral form of administration lead to the need for their detection in modern doping control. The purpose of this research was to develop an approach to differentiate cobalt from vitamin B12, present in the body in its natural state, from the intake of cobalt salts by quantifying and comparing blood levels of vitamin B12 and total cobalt. Methods. The study involved 9 healthy volunteers (women and men) aged 25 to 45 years, leading an active lifestyle. Three of them took 2500 µg/day of cobalamin for 20 days (comparison group), three - dietary supplement containing cobalt asparaginate (100 µg/day in terms of pure cobalt), and the rest - dietary supplements with cobalt sulfate heptahydrate (100 µg/day in terms of pure cobalt) (administration groups) at the same time after meals. Blood samples were taken at baseline and on days 5, 9, 14 and 20. The concentrations of total cobalt in blood plasma samples of volunteers were measured by inductively coupled plasma mass-spectrometry (ICP-MS), the levels of cobalamin were determined on a Cobas 6000 immunochemical analyzer using the Elecsys Vitamin B12 II Assay ELISA kits. Results. It was found that oral intake of of cobalamin at a therapeutic dose significantly exceeding the recommended daily intake (3 µg), there was a regular slight increase in the blood concentration of total cobalt (1.1 times). At the same time intake of dietary supplements containing cobalt in the form of sulfate or asparaginate (about 100 µg per day in terms of pure cobalt) was accompanied by 4-6.7 fold increase in the concentration of total cobalt while unchanged vitamin B12 plasma concentration was observed. The detection of such changes can reliably indicate the use of prohibited salts and, of course, will be in demand for anti-doping control. Conclusion. Long-term monitoring of vitamin B12 and total cobalt levels, similar to hematological module of the Athlete Biological Passport program, will unambiguously detect possible abuse of cobalt salts and can be an additional evidence of the presence of these doping substances to other analytical methods, such as a combination of liquid chromatography and ICP-MS (LC-ICP-MS).


Asunto(s)
Cobalto , Suplementos Dietéticos , Sales (Química) , Femenino , Humanos , Masculino , Cobalto/administración & dosificación , Cobalto/sangre , Suplementos Dietéticos/análisis , Plasma/química , Vitamina B 12/análisis , Adulto , Persona de Mediana Edad
20.
Clin Orthop Relat Res ; 479(12): 2633-2650, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34232144

RESUMEN

BACKGROUND: The evaluation of the natural history prevalence of adverse local tissue reactions (ALTRs) using MRI has focused only on metal-on-metal (MoM) bearing surfaces without comparison to nonMoM bearing surfaces. QUESTIONS/PURPOSES: To determine (1) the longitudinal changes and differences in blood metal ion levels in patients with hip resurfacing arthroplasty (HRA), ceramic-on-ceramic (CoC) THA, and metal-on-polyethylene (MoP) THA compared with those undergoing ceramic-on-polyethylene (CoP) THA; (2) how the longitudinal change of synovial reaction classification in patients with HRA, CoC THA, and MoP THA compares with those undergoing CoP THA, and whether there is an association between the presence of an ALTR or metallosis on MRI with corresponding patient-reported outcomes, or the presence of capsular dehiscence; and (3) differences in blood metal ion levels between patients undergoing HRA with an ALTR or metallosis on MRI and those with HRA without these conditions. METHODS: Between March 2014 and February 2019, 22,723 patients underwent primary HRA and THA at one center. Patients received an HRA based on their desired athletic level after surgery and the presence of normal acetabular and proximal femoral bone morphology without osteopenia or osteoporosis. Two percent (342 of 22,723) of patients were contacted to participate, and 71% (243 of 342 hips in 206 patients) were enrolled for analysis at baseline. The patients underwent arthroplasty for degenerative joint disease, and 25 patients withdrew over the course of the study. We included patients who were more than 1 year postarthroplasty. All participants had an MRI examination and blood serum ion testing and completed a Hip Disability and Osteoarthritis Outcome Score survey annually for four years (baseline, year 1, year 2, year 3). Morphologic and susceptibility-reduced MR images were evaluated by a single radiologist not involved in the care of patients for the presence and classification of synovitis (Gwet AC1: 0.65 to 0.97), synovial thickness, and volume (coefficient of repeatability: 1.8 cm3). Linear mixed-effects models were used to compare the mean synovial thickness, synovial volume, and Hip Disability and Osteoarthritis Outcome Score subscales between bearing surfaces at each timepoint and within each bearing surface over time. Marginal Cox proportional hazards models were used to compare the time to and the risk of developing ALTR only, metallosis only, and ALTR or metallosis between bearing surfaces. All models were adjusted for age, sex, BMI, and length of implantation based on known confounders for hip arthroplasty. Adjustment for multiple comparisons was performed using the Dunnett-Hsu method. RESULTS: Patients with unilateral HRA had higher cobalt and chromium serum ion levels (baseline: 1.8 ± 0.8 ppb, year 1: 2.0 ± 1.5 ppb, year 2: 2.1 ± 1.2 ppb, year 3: 1.6 ± 0.7 ppb) than those with unilateral CoP bearings (baseline: 0.0 ± 0.1 ppb, year 1: 0.1 ± 0.3 ppb, year 2: 0.0 ± 0.2 ppb, year 3: 0.0 ± 0.0 ppb) at all timepoints (p < 0.001 for each time point). More patients who received an HRA developed ALTR or metallosis on MRI than did patients with CoP bearings (hazard ratio 4.8 [95% confidence interval 1.2 to 18.4]; p = 0.02). There was no association between the longitudinal change of synovial reaction to ALTR or metallosis on MRI with patient-reported outcomes. In addition, there was no association between the presence of dehiscence at baseline and the subsequent development of ALTR or metallosis, as seen on MRI. There were elevated cobalt (4.7 ± 3.5 ppb) and chromium (4.7 ± 2.6 ppb) serum levels in patients with unilateral HRA who had an ALTR or metallosis present on MRI at year 1 compared with patients without an ALTR or metallosis on MRI (cobalt: 1.8 ± 1.0 ppb, mean difference 4.7 ppb [95% CI 3.3 to 6.0]; p < 0.001; chromium: 2.3 ± 0.5 ppb, mean difference 3.6 ppb [95% CI 2.2 to 5.0]; p < 0.001) as well as for chromium at year 3 (3.9 ± 2.4 ppb versus 2.2 ± 1.1 ppb, mean difference 1.3 ppb [95% CI 0.3 to 2.4]; p = 0.01). CONCLUSION: We found a higher proportion of ALTR or metallosis on MRI in patients with HRA compared with patients with CoP, even when patient self-assessed symptomatology of those with an ALTR or metallosis on MRI was not different than the absence of these features. MRI detected ALTRs in high-function patients, emphasizing that an annual clinical assessment dependent on survey or blood ion testing alone may not detect soft tissue complications. The results of this study are in line with prior consensus recommendations of using MRI as part of a routine follow-up protocol for this patient population. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Reacción a Cuerpo Extraño/epidemiología , Prótesis de Cadera/efectos adversos , Complicaciones Posoperatorias , Diseño de Prótesis/efectos adversos , Sinovitis/epidemiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Enfermedades Asintomáticas/epidemiología , Cerámica , Cromo/sangre , Cobalto/sangre , Evaluación de la Discapacidad , Reacción a Cuerpo Extraño/diagnóstico por imagen , Reacción a Cuerpo Extraño/etiología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/patología , Articulación de la Cadera/cirugía , Humanos , Iones/sangre , Cápsula Articular/diagnóstico por imagen , Cápsula Articular/patología , Cápsula Articular/cirugía , Modelos Lineales , Estudios Longitudinales , Imagen por Resonancia Magnética , Prótesis Articulares de Metal sobre Metal/efectos adversos , Medición de Resultados Informados por el Paciente , Polietileno , Periodo Posoperatorio , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Falla de Prótesis , Medición de Riesgo , Factores de Riesgo , Sinovitis/diagnóstico por imagen , Sinovitis/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA