1.
Arq Bras Cir Dig ; 37: e1815, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39140571

RESUMEN

BACKGROUND: Colorectal cancer is the third most common type of cancer in Brazil, despite the availability of screening methods that reduce its risk. Colonoscopy is the only screening method that also allows therapeutic procedures. The proper screening through colonoscopy is linked to the quality of the exam, which can be evaluated according to quality criteria recommended by various institutions. Among the factors, the most used is the Adenoma Detection Rate, which should be at least 25% for general population. AIMS: To evaluate the quality of the screening colonoscopies performed in a quarternary private Brazilian hospital. METHODS: This is a retrospective study evaluating the quality indicators of colonoscopies performed at a private center since its inauguration. Only asymptomatic patients aged over 45 years who underwent screening colonoscopy were included. The primary outcome was the Adenoma Detection Rate, and secondary outcomes included polyps detection rate and safety profile. Subanalyses evaluated the correlation of endoscopic findings with gender and age and the evolution of detection rates over the years. RESULTS: A total of 2,144 patients were include with a mean age of 60.54 years-old. Polyps were diagnosed in 68.6% of the procedures. Adenoma detection rate was 46.8%, with an increasing rate over the years, mainly in males. A low rate of adverse events was reported in 0.23% of the cases, with no need for surgical intervention and no deaths. CONCLUSIONS: This study shows that high quality screening colonoscopy is possible when performed by experienced endoscopists and trained nurses, under an adequate infrastructure.


Asunto(s)
Colonoscopía , Hospitales Privados , Indicadores de Calidad de la Atención de Salud , Humanos , Colonoscopía/normas , Estudios Retrospectivos , Masculino , Persona de Mediana Edad , Femenino , Brasil , Anciano , Detección Precoz del Cáncer/normas , Adenoma/diagnóstico , Neoplasias Colorrectales/diagnóstico
2.
Turk J Gastroenterol ; 35(6): 488-496, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-39114910

RESUMEN

Quality indicators during the insertion phase of colonoscopy require exploration. Unsatisfactory insertion experiences cause endoscopist psychophysiological fatigue and affect the quality of their inspection. This comparative study used propensity score matching (PSM) to determine whether endoscopist satisfaction during scope insertion was related to polyp detection rate (PDR). Patients who underwent colonoscopy screening between April 2019 and December 2022 were enrolled in this study. The endoscopist satisfaction score (high and low) during the insertion phase in each examination was recorded based on the level of fatigue and presence of paradoxical scope movement. All examinations were classified into 2 groups: a high and a low satisfaction score group. After PSM with potential confounding factors related to polyp detection (endoscopist, insertion and withdrawal time, and sedative agent use), the PDR and adenoma detection rate (ADR) were compared. Overall, 4142 patients (average age, 54.1 years old; 54.4% male) underwent colonoscopies performed by twelve experienced endoscopists. Analysis using a logistic regression model revealed that a high satisfaction score during the insertion phase was an independent predictor of polyp detection (P < .001, odds ratio 1.79, 95% CI 1.41-2.33), whereas insertion time was not. After PSM, 513 patients from both groups were eligible for comparison. Polyp detection rate and ADR were significantly higher in the high-satisfaction group than in the low-satisfaction group (49.5% vs. 36.6%, P < .001; 35.1% vs. 27.1%, P = .007). The endoscopists' level of satisfaction with the insertion phase was shown to be a potential predictor of PDR in screening colonoscopy.


Asunto(s)
Pólipos del Colon , Colonoscopía , Puntaje de Propensión , Humanos , Colonoscopía/normas , Colonoscopía/estadística & datos numéricos , Masculino , Femenino , Persona de Mediana Edad , Pólipos del Colon/diagnóstico , Indicadores de Calidad de la Atención de Salud , Neoplasias Colorrectales/diagnóstico , Adulto , Adenoma/diagnóstico , Anciano , Satisfacción Personal
3.
BMC Gastroenterol ; 24(1): 272, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160458

RESUMEN

BACKGROUND: There is a growing demand for colonoscopy, worldwide, resulting in increased rate of inappropriate referrals. This "overuse" of colonoscopies has become a major burden for health care. OBJECTIVES: to assess the appropriateness of colonoscopies performed at the endoscopy unit of the university hospital of Sousse and to compare these results of appropriateness according to the European Panel of Appropriateness of Gastrointestinal Endoscopy (EPAGE) I and EPAGE II criteria. PATIENTS AND METHODS: this cross-sectional study included all consecutive patients referred for a diagnostic colonoscopy, between January 2017 and December 2018. Patients referred for exclusively therapeutic indications, those with incomplete colonoscopies were not included. Patients with poor bowel preparation or missing data were also excluded. Indications were assessed using the EPAGE I and EPAGE II criteria. RESULTS: From 1972 consecutive patients, 1307 were included. Overall, 986 (75.4%) of all referrals were for out-patients. The majority of patients were referred by gastroenterologists (n = 1026 patients; 78.5%), followed by general surgeons (n = 85; 6.5%). The commonest indications were lower abdominal symptoms (275; 21%) followed by uncomplicated diarrhea (152; 11.6%). Relevant findings were present in 363 patients (27.7%). Neoplastic lesions were the dominant finding in 221 patients (16.9%). EPAGE I and EPAGE II criteria were applicable for 1237 (88.8%) and 1276 (97.7%) patients respectively. Hematochezia and abdominal pain recorded the highest inappropriate rates with both sets of criteria. Appropriate colonoscopies increased to 76.4% when EPAGE II criteria were applied; whereas uncertain and inappropriate procedures decreased to 10.3% and 10.9% respectively Appropriateness of indication was significantly higher in hospitalized patients. For the EPAGE II criteria, the specialty of the referring physician was also significantly associated to the appropriate use. The agreement between EPAGE I and EPAGE II criteria was slight using the weighted version of k (k = 0.153). CONCLUSIONS: The updated and improved EPAGE II guidelines are a simple and valid tool for assessing the appropriateness of colonoscopies. They decreased the inappropriate rate and the possibility of missing potentially severe diagnoses.


Asunto(s)
Colonoscopía , Derivación y Consulta , Humanos , Colonoscopía/estadística & datos numéricos , Colonoscopía/normas , Estudios Transversales , Masculino , Femenino , Persona de Mediana Edad , Derivación y Consulta/estadística & datos numéricos , Túnez , Anciano , Adulto , Procedimientos Innecesarios/estadística & datos numéricos , Guías de Práctica Clínica como Asunto
5.
World J Gastroenterol ; 30(28): 3361-3366, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39091719

RESUMEN

In this editorial, we discuss the article by Agatsuma et al. We concentrate specifically on the current routinely used screening tests recommended by society guidelines and delve into the significance of early diagnosis of colorectal cancer (CRC) and its substantial impact on both incidence and mortality rates. Screening is highly recommended, and an early diagnosis stands out as the most crucial predictor of survival for CRC patients. Therefore, it is essential to identify and address the barriers hindering adherence to screening measures, as these barriers can vary among different populations. Furthermore, we focus on screening strategy optimization by selecting high-risk groups. Patients with comorbidities who regularly visit hospitals have been diagnosed at an early stage, showing no significant difference compared to patients undergoing regular screening. This finding highlights the importance of extending screening measures to include patients with comorbidities who do not routinely visit the hospital.


Asunto(s)
Neoplasias Colorrectales , Detección Precoz del Cáncer , Humanos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/epidemiología , Neoplasias Colorrectales/mortalidad , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/estadística & datos numéricos , Detección Precoz del Cáncer/normas , Tamizaje Masivo/métodos , Tamizaje Masivo/normas , Tamizaje Masivo/estadística & datos numéricos , Comorbilidad , Guías de Práctica Clínica como Asunto , Factores de Riesgo , Colonoscopía/normas , Incidencia , Sangre Oculta
6.
BMC Gastroenterol ; 24(1): 257, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123140

RESUMEN

BACKGROUND: Construct deep learning models for colonoscopy quality control using different architectures and explore their decision-making mechanisms. METHODS: A total of 4,189 colonoscopy images were collected from two medical centers, covering different levels of bowel cleanliness, the presence of polyps, and the cecum. Using these data, eight pre-trained models based on CNN and Transformer architectures underwent transfer learning and fine-tuning. The models' performance was evaluated using metrics such as AUC, Precision, and F1 score. Perceptual hash functions were employed to detect image changes, enabling real-time monitoring of colonoscopy withdrawal speed. Model interpretability was analyzed using techniques such as Grad-CAM and SHAP. Finally, the best-performing model was converted to ONNX format and deployed on device terminals. RESULTS: The EfficientNetB2 model outperformed other architectures on the validation set, achieving an accuracy of 0.992. It surpassed models based on other CNN and Transformer architectures. The model's precision, recall, and F1 score were 0.991, 0.989, and 0.990, respectively. On the test set, the EfficientNetB2 model achieved an average AUC of 0.996, with a precision of 0.948 and a recall of 0.952. Interpretability analysis showed the specific image regions the model used for decision-making. The model was converted to ONNX format and deployed on device terminals, achieving an average inference speed of over 60 frames per second. CONCLUSIONS: The AI-assisted quality system, based on the EfficientNetB2 model, integrates four key quality control indicators for colonoscopy. This integration enables medical institutions to comprehensively manage and enhance these indicators using a single model, showcasing promising potential for clinical applications.


Asunto(s)
Colonoscopía , Aprendizaje Profundo , Control de Calidad , Colonoscopía/normas , Humanos , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/diagnóstico
7.
World J Gastroenterol ; 30(25): 3140-3142, 2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-39006381

RESUMEN

This editorial comments on the article entitled "Stage at diagnosis of colorectal cancer through diagnostic route: Who should be screened?" by Agatsuma et al, who conducted a retrospective study aiming at clarifying the stage at colorectal cancer (CRC) diagnosis based on different diagnostic routes. We share our opinion about CRC screening programs. The current situation suggests the need for a more specific and targeted population for CRC screening.


Asunto(s)
Neoplasias Colorrectales , Detección Precoz del Cáncer , Tamizaje Masivo , Estadificación de Neoplasias , Humanos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/epidemiología , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/normas , Detección Precoz del Cáncer/estadística & datos numéricos , Tamizaje Masivo/métodos , Tamizaje Masivo/normas , Tamizaje Masivo/estadística & datos numéricos , Colonoscopía/estadística & datos numéricos , Colonoscopía/normas
8.
Medicina (Kaunas) ; 60(7)2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39064595

RESUMEN

Background and Objectives: The implementation and monitoring of the European Society of Gastrointestinal Endoscopy (ESGE) performance measures for colonoscopy are suboptimal in clinical practice. Electronic reporting systems may play an important role in data retrieval. We aimed to define the possibility of systematically assessing and monitoring ESGE performance measures for colonoscopy through reporting systems. Materials and Methods: We conducted a survey during a nationwide event on the quality of colonoscopy held in Rome, Italy, in March 2023 by a self-administered questionnaire. Analyses were conducted overall and by workplace setting. Results: The attendance was 93% (M/F 67/26), with equal distribution of age groups, regions and public or private practices. Only about one-third (34%) and 21.5% of participants stated that their reporting system allows them to retrieve all the ESGE performance measures, overall and as automatic retrieval, respectively. Only 66.7% and 10.7% of respondents can systematically report the cecal intubation and the adenoma detection rate, respectively. The analysis according to hospital setting revealed no significant difference for all the items. Conclusions: We found a generalized lack of systematic tracking of performance measures for colonoscopy due to underperforming reporting systems. Our results underline the need to update reporting systems to monitor the quality of endoscopy practice in Italy.


Asunto(s)
Colonoscopía , Humanos , Colonoscopía/normas , Colonoscopía/estadística & datos numéricos , Encuestas y Cuestionarios , Masculino , Femenino , Persona de Mediana Edad , Italia , Adulto , Anciano , Endoscopía Gastrointestinal/normas , Endoscopía Gastrointestinal/estadística & datos numéricos , Sociedades Médicas , Europa (Continente)
9.
Am J Med Qual ; 39(4): 154-160, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38885415

RESUMEN

Inadequate inpatient bowel preparation can lead to repeat procedures, prolonged hospital stays, and increased financial burden. In this quality improvement project, the authors developed an electronic medical record (EMR)-based order set with precise instructions and anticipatory guidance for inpatient bowel preparation before colonoscopy. The current study is a nonrandomized intervention study. The authors compared 2 groups: an intervention group using a newly developed, consensus-based, standardized EMR bowel preparation order set and a control group using previously existing EMR bowel preparation orders. Bowel preparation outcomes were followed over the course of 16 months. The aim was to improve inpatient colonoscopy bowel preparation, as evaluated by the Boston Bowel Preparation Scale, procedure delays, and length of hospital stay. We additionally evaluated the groups' demographics and patient-level factors. A total of 459 inpatient colonoscopies were evaluated over a 16-month period. The intervention group consisted of 227 inpatient colonoscopies, while the control group consisted of 232. The intervention group showed superior Boston Bowel Preparation Scale score and decreased length of hospital stay. The number of adequate bowel preparations increased in the intervention group when compared to the control group from 77% to 86%. The creation of an EMR-based order set is a low-cost and sustainable action that can be easily implemented throughout a hospital system.


Asunto(s)
Catárticos , Colonoscopía , Tiempo de Internación , Mejoramiento de la Calidad , Humanos , Colonoscopía/normas , Mejoramiento de la Calidad/organización & administración , Femenino , Masculino , Persona de Mediana Edad , Catárticos/administración & dosificación , Tiempo de Internación/estadística & datos numéricos , Anciano , Registros Electrónicos de Salud , Pacientes Internos , Adulto
11.
Clin Gastroenterol Hepatol ; 22(9): 1917-1925.e17, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38729387

RESUMEN

BACKGROUND & AIMS: Large language models including Chat Generative Pretrained Transformers version 4 (ChatGPT4) improve access to artificial intelligence, but their impact on the clinical practice of gastroenterology is undefined. This study compared the accuracy, concordance, and reliability of ChatGPT4 colonoscopy recommendations for colorectal cancer rescreening and surveillance with contemporary guidelines and real-world gastroenterology practice. METHODS: History of present illness, colonoscopy data, and pathology reports from patients undergoing procedures at 2 large academic centers were entered into ChatGPT4 and it was queried for the next recommended colonoscopy follow-up interval. Using the McNemar test and inter-rater reliability, we compared the recommendations made by ChatGPT4 with the actual surveillance interval provided in the endoscopist's procedure report (gastroenterology practice) and the appropriate US Multisociety Task Force (USMSTF) guidance. The latter was generated for each case by an expert panel using the clinical information and guideline documents as reference. RESULTS: Text input of de-identified data into ChatGPT4 from 505 consecutive patients undergoing colonoscopy between January 1 and April 30, 2023, elicited a successful follow-up recommendation in 99.2% of the queries. ChatGPT4 recommendations were in closer agreement with the USMSTF Panel (85.7%) than gastroenterology practice recommendations with the USMSTF Panel (75.4%) (P < .001). Of the 14.3% discordant recommendations between ChatGPT4 and the USMSTF Panel, recommendations were for later screening in 26 (5.1%) and for earlier screening in 44 (8.7%) cases. The inter-rater reliability was good for ChatGPT4 vs USMSTF Panel (Fleiss κ, 0.786; 95% CI, 0.734-0.838; P < .001). CONCLUSIONS: Initial real-world results suggest that ChatGPT4 can define routine colonoscopy screening intervals accurately based on verbatim input of clinical data. Large language models have potential for clinical applications, but further training is needed for broad use.


Asunto(s)
Colonoscopía , Neoplasias Colorrectales , Humanos , Colonoscopía/métodos , Colonoscopía/normas , Femenino , Masculino , Neoplasias Colorrectales/diagnóstico , Persona de Mediana Edad , Anciano , Detección Precoz del Cáncer/métodos , Reproducibilidad de los Resultados , Inteligencia Artificial
14.
J Natl Cancer Inst ; 116(8): 1264-1269, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38588561

RESUMEN

BACKGROUND: Colorectal cancer is the third most diagnosed cancer and the second leading cause of cancer death in the United States. Colonoscopy is an essential tool for screening, used as a primary approach and follow-up to an abnormal stool-based colorectal cancer screening result. Colonoscopy quality is often measured with 4 key indicators: bowel preparation, cecal intubation, mean withdrawal time, and adenoma detection. Colonoscopies are most often performed by gastroenterologists (GI), however, in rural and medically underserved areas, non-GI providers often perform colonoscopies. This study aims to evaluate the quality and safety of screening colonoscopies performed by non-GI practitioner, comparing their outcomes with those of GI providers. METHODS: Descriptive statistics were used to characterize the study population. Results for quality indicators were stratified by provider type and compared. Statistical significance was determined using a P value of less than .05 as the threshold for all comparisons; all P values were 2-sided. RESULTS: No statistical difference was found when comparing performance by provider type. Median performance for gastroenterologists, general surgeons, and family medicine providers ranged from 98% to 100% for cecal intubation; 97.4% to 100% for bowel preparation; 57.4% to 88.9% for male adenoma detection rate; 47.7% to 62.13% for female adenoma detection rate; and 0:12:10 to 0:20:16 for mean withdrawal time. All provider types met and exceeded the goal metric for each of the quality indicators (P < .001). CONCLUSIONS: As a result of this analysis, we can expect non-GI practitioner to perform colonoscopies with similar quality to GI practitioner given the performance outcomes for the key quality metrics.


Asunto(s)
Colonoscopía , Neoplasias Colorrectales , Detección Precoz del Cáncer , Humanos , Colonoscopía/normas , Colonoscopía/estadística & datos numéricos , Masculino , Femenino , Neoplasias Colorrectales/diagnóstico , Persona de Mediana Edad , Detección Precoz del Cáncer/normas , Detección Precoz del Cáncer/métodos , Anciano , Indicadores de Calidad de la Atención de Salud , Adenoma/diagnóstico , Gastroenterólogos/normas , Estados Unidos , Calidad de la Atención de Salud
15.
Endoscopy ; 56(7): 516-545, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38670139

RESUMEN

1: ESGE recommends cold snare polypectomy (CSP), to include a clear margin of normal tissue (1-2 mm) surrounding the polyp, for the removal of diminutive polyps (≤ 5 mm).Strong recommendation, high quality of evidence. 2: ESGE recommends against the use of cold biopsy forceps excision because of its high rate of incomplete resection.Strong recommendation, moderate quality of evidence. 3: ESGE recommends CSP, to include a clear margin of normal tissue (1-2 mm) surrounding the polyp, for the removal of small polyps (6-9 mm).Strong recommendation, high quality of evidence. 4: ESGE recommends hot snare polypectomy for the removal of nonpedunculated adenomatous polyps of 10-19 mm in size.Strong recommendation, high quality of evidence. 5: ESGE recommends conventional (diathermy-based) endoscopic mucosal resection (EMR) for large (≥ 20 mm) nonpedunculated adenomatous polyps (LNPCPs).Strong recommendation, high quality of evidence. 6: ESGE suggests that underwater EMR can be considered an alternative to conventional hot EMR for the treatment of adenomatous LNPCPs.Weak recommendation, moderate quality of evidence. 7: Endoscopic submucosal dissection (ESD) may also be suggested as an alternative for removal of LNPCPs of ≥ 20 mm in selected cases and in high-volume centers.Weak recommendation, low quality evidence. 8: ESGE recommends that, after piecemeal EMR of LNPCPs by hot snare, the resection margins should be treated by thermal ablation using snare-tip soft coagulation to prevent adenoma recurrence.Strong recommendation, high quality of evidence. 9: ESGE recommends (piecemeal) cold snare polypectomy or cold EMR for SSLs of all sizes without suspected dysplasia.Strong recommendation, moderate quality of evidence. 10: ESGE recommends prophylactic endoscopic clip closure of the mucosal defect after EMR of LNPCPs in the right colon to reduce to reduce the risk of delayed bleeding.Strong recommendation, high quality of evidence. 11: ESGE recommends that en bloc resection techniques, such as en bloc EMR, ESD, endoscopic intermuscular dissection, endoscopic full-thickness resection, or surgery should be the techniques of choice in cases with suspected superficial invasive carcinoma, which otherwise cannot be removed en bloc by standard polypectomy or EMR.Strong recommendation, moderate quality of evidence.


Asunto(s)
Pólipos del Colon , Resección Endoscópica de la Mucosa , Humanos , Resección Endoscópica de la Mucosa/métodos , Resección Endoscópica de la Mucosa/normas , Pólipos del Colon/cirugía , Colonoscopía/normas , Colonoscopía/métodos , Colonoscopía/instrumentación , Neoplasias Colorrectales/cirugía , Márgenes de Escisión , Pólipos Adenomatosos/cirugía , Pólipos Adenomatosos/patología , Europa (Continente) , Sociedades Médicas/normas
16.
Gastrointest Endosc ; 100(2): 167-176.e1, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38580134

RESUMEN

BACKGROUND AND AIMS: Endoscopists' competence can vary widely, as shown in the variation in the adenoma detection rate (ADR). Computer-aided quality assessment (CAQ) can automatically assess performance during individual procedures. In this review we identified and described different CAQ systems for colonoscopy. METHODS: A systematic review of the literature was done using MEDLINE, EMBASE, and Scopus based on 3 blocks of terms according to the inclusion criteria: colonoscopy, competence assessment, and automatic evaluation. Articles were systematically reviewed by 2 reviewers, first by abstract and then in full text. The methodological quality was assessed using the Medical Education Research Study Quality Instrument (MERSQI). RESULTS: Of 12,575 identified studies, 6831 remained after removal of duplicates and 6806 did not pass the eligibility criteria and were excluded, leaving 25 studies, of which 13 studies were included in the final analysis. Five categories of CAQ systems were identified: withdrawal speedometer (7 studies), endoscope movement analysis (3 studies), effective withdrawal time (1 study), fold examination quality (1 study), and visual gaze pattern (1 study). The withdrawal speedometer was the only CAQ system that tested its feedback by examining changes in ADR. Three studies observed an improvement in ADR, and 2 studies did not. The methodological quality of the studies was high (mean MERSQI, 15.2 points; maximum, 18 points). CONCLUSIONS: Thirteen studies developed or tested CAQ systems, most frequently by correlating it to the ADR. Only 5 studies tested feedback by implementing the CAQ system. A meta-analysis was impossible because of the heterogeneous study designs, and more studies are warranted.


Asunto(s)
Competencia Clínica , Colonoscopía , Humanos , Colonoscopía/normas , Adenoma/diagnóstico , Garantía de la Calidad de Atención de Salud
17.
Digestion ; 105(3): 224-231, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38479373

RESUMEN

INTRODUCTION: Comprehensive and standardized colonoscopy reports are crucial in colorectal cancer prevention, monitoring, and research. This study investigates adherence to national and international guidelines by analyzing reporting practices among 21 endoscopists in 7 German centers, with a focus on polyp reporting. METHODS: We identified and assessed German, European, American, and World Health Organization-provided statements to identify key elements in colonoscopy reporting. Board-certified gastroenterologists rated the relevance of each element and estimated their reporting frequency. Adherence to the identified report elements was evaluated for 874 polyps from 351 colonoscopy reports ranging from March 2021 to March 2022. RESULTS: We identified numerous recommendations for colonoscopy reporting. We categorized the reasoning behind those recommendations into clinical relevance, justification, and quality control and research. Although all elements were considered relevant by the surveyed gastroenterologists, discrepancies were observed in the evaluated reports. Particularly diminutive polyps or attributes which are rarely abnormal (e.g., surface integrity) respectively rarely performed (e.g., injection) were sparsely documented. Furthermore, the white light morphology of polyps was inconsistently documented using either the Paris classification or free text. In summary, the analysis of 874 reported polyps revealed heterogeneous adherence to the recommendations, with reporting frequencies ranging from 3% to 89%. CONCLUSION: The inhomogeneous report practices may result from implicit reporting practices and recommendations with varying clinical relevance. Future recommendations should clearly differentiate between clinical relevance and research and quality control or explanatory purposes. Additionally, the role of computer-assisted documentation should be further evaluated to increase report frequencies of non-pathological findings and diminutive polyps.


Asunto(s)
Pólipos del Colon , Colonoscopía , Neoplasias Colorrectales , Adhesión a Directriz , Humanos , Colonoscopía/normas , Colonoscopía/estadística & datos numéricos , Colonoscopía/métodos , Adhesión a Directriz/estadística & datos numéricos , Pólipos del Colon/patología , Pólipos del Colon/diagnóstico , Alemania , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina/estadística & datos numéricos , Pautas de la Práctica en Medicina/normas , Mejoramiento de la Calidad , Gastroenterólogos/estadística & datos numéricos , Gastroenterólogos/normas , Documentación/normas , Documentación/estadística & datos numéricos , Documentación/métodos
18.
Endoscopy ; 56(9): 706-709, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38499197

RESUMEN

BACKGROUND: Society guidelines on colorectal dysplasia screening, surveillance, and endoscopic management in inflammatory bowel disease (IBD) are complex, and physician adherence to them is suboptimal. We aimed to evaluate the use of ChatGPT, a large language model, in generating accurate guideline-based recommendations for colorectal dysplasia screening, surveillance, and endoscopic management in IBD in line with European Crohn's and Colitis Organization (ECCO) guidelines. METHODS: 30 clinical scenarios in the form of free text were prepared and presented to three separate sessions of ChatGPT and to eight gastroenterologists (four IBD specialists and four non-IBD gastroenterologists). Two additional IBD specialists subsequently assessed all responses provided by ChatGPT and the eight gastroenterologists, judging their accuracy according to ECCO guidelines. RESULTS: ChatGPT had a mean correct response rate of 87.8%. Among the eight gastroenterologists, the mean correct response rates were 85.8% for IBD experts and 89.2% for non-IBD experts. No statistically significant differences in accuracy were observed between ChatGPT and all gastroenterologists (P=0.95), or between ChatGPT and the IBD experts and non-IBD expert gastroenterologists, respectively (P=0.82). CONCLUSIONS: This study highlights the potential of language models in enhancing guideline adherence regarding colorectal dysplasia in IBD. Further investigation of additional resources and prospective evaluation in real-world settings are warranted.


Asunto(s)
Neoplasias Colorrectales , Adhesión a Directriz , Enfermedades Inflamatorias del Intestino , Guías de Práctica Clínica como Asunto , Humanos , Enfermedades Inflamatorias del Intestino/terapia , Neoplasias Colorrectales/terapia , Neoplasias Colorrectales/diagnóstico , Europa (Continente) , Lenguaje , Gastroenterólogos , Colonoscopía/normas , Gastroenterología/normas
19.
Gastroenterology ; 167(3): 560-590, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38513744

RESUMEN

BACKGROUND & AIMS: Significant variability exists in colonoscopy quality indicators, including adenoma detection rate (ADR). We synthesized evidence from randomized trials in a network meta-analysis on interventions to improve colonoscopy quality. METHODS: We included trials from database inceptions to September 25, 2023, of patients undergoing screening-related colonoscopy and presented efficacies of interventions within domains (periprocedural parameters, endoscopist-directed interventions, intraprocedural techniques, endoscopic technologies, distal attachment devices, and additive substances) compared to standard colonoscopy. The primary outcome was ADR. We used a Bayesian random-effects model using Markov-chain Monte Carlo simulation, with 10,000 burn-ins and 100,000 iterations. We calculated odds ratios with 95% credible intervals and present surface under the cumulative ranking (SUCRA) curves. RESULTS: We included 124 trials evaluating 37 interventions for the primary outcome. Nine interventions resulted in statistically significant improvements in ADR compared to standard colonoscopy (9-minute withdrawal time, dual observation, water exchange, i-SCAN [Pentax Ltd], linked color imaging, computer-aided detection, Endocuff [Olympus Corp], Endocuff Vision [Olympus Corp], and oral methylene blue). Dual observation (SUCRA, 0.84) and water exchange (SUCRA, 0.78) ranked highest among intraprocedural techniques; i-SCAN (SUCRA, 0.95), linked color imaging (SUCRA, 0.85), and computer-aided detection (SUCRA, 0.78) among endoscopic technologies; WingCap (A&A Medical Supply LLC) (SUCRA, 0.87) and Endocuff (SUCRA, 0.85) among distal attachment devices and oral methylene blue (SUCRA, 0.94) among additive substances. No interventions improved detection of advanced adenomas, and only narrow-band imaging improved detection of serrated lesions (odds ratio, 2.94; 95% credible interval, 1.46-6.25). CONCLUSIONS: Several interventions are effective in improving adenoma detection and overall colonoscopy quality, many of which are cost-free. These results can inform endoscopists, unit managers, and endoscopy societies on relative efficacies.


Asunto(s)
Adenoma , Colonoscopía , Detección Precoz del Cáncer , Metaanálisis en Red , Ensayos Clínicos Controlados Aleatorios como Asunto , Colonoscopía/normas , Humanos , Adenoma/diagnóstico por imagen , Adenoma/diagnóstico , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/normas , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/diagnóstico por imagen , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud , Teorema de Bayes
20.
Gastrointest Endosc ; 100(3): 510-516.e6, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38331224

RESUMEN

BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large nonpedunculated colorectal polyps are often referred to expert centers for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of this study was to establish minimum expected standards for the referral of large nonpedunculated colonic polyps for potential endoscopic resection. METHODS: A Delphi method was used to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and 3 rounds of surveys were conducted to achieve consensus. Quantitative and qualitative data were analyzed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographic characteristics, relevant medications, lesion factors, photodocumentation, and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements, which were scored on a scale of 1 to 10, ranged from 7.04 to 9.29, with high percentages of experts considering most statements as a very high priority. Subgroup analysis according to continent revealed some variations in consensus rates among experts from different regions. CONCLUSIONS: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.


Asunto(s)
Pólipos del Colon , Colonoscopía , Consenso , Técnica Delphi , Derivación y Consulta , Humanos , Pólipos del Colon/cirugía , Pólipos del Colon/patología , Derivación y Consulta/normas , Colonoscopía/normas , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología
SELECCIÓN DE REFERENCIAS