Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.271
Filtrar
1.
PLoS One ; 19(5): e0303773, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38753829

RESUMEN

The Burkholderia cepacia complex (Bcc) is the number one bacterial complex associated with contaminated Finished Pharmaceutical Products (FPPs). This has resulted in multiple healthcare related infection morbidity and mortality events in conjunction with significant FPP recalls globally. Current microbiological quality control of FPPs before release for distribution depends on lengthy, laborious, non-specific, traditional culture-dependent methods which lack sensitivity. Here, we present the development of a culture-independent Bcc Nucleic Acid Diagnostic (NAD) method for detecting Bcc contaminants associated with Over-The-Counter aqueous FPPs. The culture-independent Bcc NAD method was validated to be specific for detecting Bcc at different contamination levels from spiked aqueous FPPs. The accuracy in Bcc quantitative measurements was achieved by the high degree of Bcc recovery from aqueous FPPs. The low variation observed between several repeated Bcc quantitative measurements further demonstrated the precision of Bcc quantification in FPPs. The robustness of the culture-independent Bcc NAD method was determined when its accuracy and precision were not significantly affected during testing of numerous aqueous FPP types with different ingredient matrices, antimicrobial preservative components and routes of administration. The culture-independent Bcc NAD method showed an ability to detect Bcc in spiked aqueous FPPs at a concentration of 20 Bcc CFU/mL. The rapid (≤ 4 hours from sample in to result out), robust, culture-independent Bcc NAD method presented provides rigorous test specificity, accuracy, precision, and sensitivity. This method, validated with equivalence to ISO standard ISO/TS 12869:2019, can be a valuable diagnostic tool in supporting microbiological quality control procedures to aid the pharmaceutical industry in preventing Bcc contamination of aqueous FPPs for consumer safety.


Asunto(s)
Complejo Burkholderia cepacia , Contaminación de Medicamentos , Complejo Burkholderia cepacia/aislamiento & purificación , Complejo Burkholderia cepacia/genética , Contaminación de Medicamentos/prevención & control , Preparaciones Farmacéuticas/análisis
2.
Molecules ; 29(9)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38731577

RESUMEN

Recently, benchtop nuclear magnetic resonance (NMR) spectrometers utilizing permanent magnets have emerged as versatile tools with applications across various fields, including food and pharmaceuticals. Their efficacy is further enhanced when coupled with chemometric methods. This study presents an innovative approach to leveraging a compact benchtop NMR spectrometer coupled with chemometrics for screening honey-based food supplements adulterated with active pharmaceutical ingredients. Initially, fifty samples seized by French customs were analyzed using a 60 MHz benchtop spectrometer. The investigation unveiled the presence of tadalafil in 37 samples, sildenafil in 5 samples, and a combination of flibanserin with tadalafil in 1 sample. After conducting comprehensive qualitative and quantitative characterization of the samples, we propose a chemometric workflow to provide an efficient screening of honey samples using the NMR dataset. This pipeline, utilizing partial least squares discriminant analysis (PLS-DA) models, enables the classification of samples as either adulterated or non-adulterated, as well as the identification of the presence of tadalafil or sildenafil. Additionally, PLS regression models are employed to predict the quantitative content of these adulterants. Through blind analysis, this workflow allows for the detection and quantification of adulterants in these honey supplements.


Asunto(s)
Suplementos Dietéticos , Miel , Espectroscopía de Resonancia Magnética , Miel/análisis , Suplementos Dietéticos/análisis , Espectroscopía de Resonancia Magnética/métodos , Citrato de Sildenafil/análisis , Flujo de Trabajo , Quimiometría/métodos , Tadalafilo/análisis , Análisis de los Mínimos Cuadrados , Contaminación de Medicamentos/prevención & control , Análisis Discriminante
3.
Int J Pharm Compd ; 28(3): 229-240, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38768508

RESUMEN

Sterilization methods to produce sterile preparations include heat, gas, radiation, and filtration. This article focuses on heat, gas, and radiation sterilization, plus a brief introduction to bright-light sterilization. Microbiology basics and microbial death kinetics, key to understanding why these sterilization methods work, will also be briefly discussed. Filtration sterilization will be covered in a separate article.


Asunto(s)
Composición de Medicamentos , Esterilización , Esterilización/métodos , Composición de Medicamentos/normas , Calor , Contaminación de Medicamentos/prevención & control , Filtración/instrumentación , Gases
4.
Zhongguo Zhong Yao Za Zhi ; 49(7): 1818-1825, 2024 Apr.
Artículo en Chino | MEDLINE | ID: mdl-38812194

RESUMEN

A label-free fluorescence method based on malachite green/aptamer was developed for the detection of ochratoxin A(OTA) in traditional Chinese medicines. Malachite green itself exhibits weak fluorescence. Upon interaction with the aptamer specific to OTA, the G-quadruplex structure of the aptamer provides a protective microenvironment for malachite green, which significantly enhances its fluorescence signal. After OTA is added, preferential binding occurs between the aptamer and OTA, and malachite green will be released from the aptamer, which weakens the fluorescence signal. According to this principle, this paper established a fluorescence method with the aptamer of OTA as the recognition element and malachite green as the fluorescent probe for the detection of OTA in traditional Chinese medicines. The key experimental factors such as the concentrations of metal ions, aptamer, and malachite green were optimized to improve the performance of the method. OTA was detected under the optimal experimental conditions, and the results showed that with the increase in OTA concentration, the fluorescence signal gradually weakened. Within the range of 20-1 000 nmol·L~(-1), the OTA concentration was linearly correlated with the fluorescence signal ratio ΔF/F(ΔF=F_0-F, where F_0 is the fluorescence signal of aptamer/malachite green, and F is the fluorescence signal of OTA/aptamer/malachite green), with R~2 of 0.995. The limit of detection of the established method was 7.1 nmol·L~(-1). Furthermore, three substances structurally similar to OTA and two mycotoxins that may coexist with OTA were selected for experiments, which aimed to examine the cross-reactivity and specificity of the established method. The cross-reactivity experiments demonstrated that the interferers did not significantly affect the fluorescence signal of the detection system. The specificity experiments revealed that when mycotoxins were mixed with OTA, the fluorescence signal generated by the mixture closely resembled that of OTA itself. The results indicated that even in the presence of interferents, the established method remained unaffected and demonstrated excellent specificity. Additionally, this method exhibited remarkable reproducibility and stability. In the case of simple centrifugation and dilution of traditional Chinese medicine samples(Puerariae Lobatae Radix, Sophorae Flavescentis Radix, and Periplocae Cortex), the OTA detection method was applicable, with recovery rates ranging from 91.5% to 121.3%. Notably, this approach does not need complex pretreatment of traditional Chinese medicines while offering simple operation, low detection costs, and short detection time. Furthermore, by incorporating aptamers into the quality evaluation of traditional Chinese medicines, this method expands the application scope of aptamers.


Asunto(s)
Aptámeros de Nucleótidos , Medicamentos Herbarios Chinos , Ocratoxinas , Colorantes de Rosanilina , Colorantes de Rosanilina/química , Colorantes de Rosanilina/análisis , Ocratoxinas/análisis , Ocratoxinas/química , Aptámeros de Nucleótidos/química , Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/análisis , Espectrometría de Fluorescencia/métodos , Contaminación de Medicamentos/prevención & control , Fluorescencia , Medicina Tradicional China
5.
J Pharm Biomed Anal ; 245: 116200, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38723557

RESUMEN

A high-performance liquid chromatography (HPLC) method was developed for the analysis of Allopurinol and its Ph.Eur. impurities using a porous graphitic carbon (PGC) stationary phase. Retention behavior of solutes was studied across a wide temperature range (30-90 °C) and various gradient times (5-20 min). Analysis of the data revealed distinct retention mechanisms between reversed-phase and PGC phases. However, it was proved that the retention of Allopurinol and its Ph.Eur. impurities on PGC stationary phase can be effectively modeled using the linear solvent strength (LSS) theory. This allows for the utilization of LSS-based method development software to optimize methods under these conditions. By using commercial chromatographic modeling software, separation of Allopurinol and Ph.Eur. impurities was optimized within a large design space. At the optimized operating conditions (pH = 2.0, tG = 6 min, T = 60 °C), all solutes were separated within 6 min with baseline resolution. Comparison between predicted and experimentally measured chromatograms further confirmed the applicability of LSS theory in developing analytical methods for PGC-based HPLC systems. The presented approach offers a general framework for method development on PGC phases.


Asunto(s)
Alopurinol , Grafito , Solventes , Cromatografía Líquida de Alta Presión/métodos , Grafito/química , Solventes/química , Alopurinol/química , Alopurinol/análisis , Porosidad , Temperatura , Contaminación de Medicamentos/prevención & control , Calor
6.
J Pharm Biomed Anal ; 245: 116160, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38663256

RESUMEN

Technical advances in the field of quality analysis allow an increasingly deeper look into the impurity profile of drugs. The ability to detect unexpected impurities in addition to known impurities ensures the supply of high-quality drugs and can prevent recalls due to the detection of harmful unexpected impurities, as has happened recently with the N-nitrosamine and azido impurities in losartan (LOS) drug products. In the present study, the LC-MS/HRMS approach described by Backer et al. was applied to an even more complex system, being the investigation of 35 LOS drug products and combination preparations purchased in 2018 and 2022 in German pharmacies. The film-coated tablets were analysed by means of four LC-MS/HRMS method variants. For the separation a Zorbax RR StableBond C18 column (3.0 ×100 mm, particle size of 3.5 µm, pore size of 80 Å), a gradient elution and for mass spectrometric detection a qTOF mass spectrometer with electrospray ionization in positive and negative mode was used. An information-dependent acquisition method was applied for the acquisition of high-resolution mass spectrometry data. The combination of an untargeted and a targeted screening approach revealed the finding of eight impurities in total. Beside the five LOS related compounds, LOS impurity F, J, K, L, M, and related compound D from amlodipine besilate, LOS azide and an unknown derivative thereof were detected. Identification and structure elucidation, respectively, were successfully performed using in silico fragmentation. Differences in the impurity profiles of drug products from 2018 and 2022 could be observed. This study shows that broad screening approaches like this are applicable to the analysis of drug products and can be an important enhancement of the quality assurance of medicinal products.


Asunto(s)
Contaminación de Medicamentos , Losartán , Comprimidos , Espectrometría de Masas en Tándem , Losartán/análisis , Losartán/química , Contaminación de Medicamentos/prevención & control , Comprimidos/análisis , Alemania , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Cromatografía Líquida de Alta Presión/métodos
7.
Klin Monbl Augenheilkd ; 241(4): 392-397, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38653293

RESUMEN

PURPOSE: To introduce a novel technique of the aseptic manufacture of autologous serum eye drops (ASEDs) with a prefiltered closed system and to analyze the sterility of the produced ophtioles between 2018 and 2022. METHODS: This is a prospective single-center study conducted at the Department of Ophthalmology at a Swiss University Hospital between 2018 and 2022. For regulatory reasons, closed systems for manufacturing ASEDs are strongly recommended. We attached an upstream sterile filter (Sterivex PES0.22 µm Burlington, USA) to a commercially available closed system (COL System Modena, Italy) for manufacturing ASEDs. The goal of this novel approach was to reduce the microbiological contamination of the donated autologous blood. Using the presented manufacturing method, we are able to produce, on average, 56 ophtioles per batch, containing either 1.45 mL or 2.5 mL of autologous serum per ophtiole. For each batch of ASEDs, we performed a microbiological analysis by automated blood culture testing (BACTEC). This system examines the presence of bacteria and fungi. RESULTS: We analyzed all manufactured batches between 2018 and 2022. None of the 2297 batches and the resulting 129 060 ophtioles showed bacterial or mycotic contamination. During the analyzed period, two batches were discarded: one due to fibrin-lipid aggregations, further microbiological and histological work-up excluded any contamination; another due to false-positive HIV in serological testing. Overall, the contamination rate was 0%, and the batch discharge rate was 0.09%. CONCLUSIONS: The combination of upstream sterile filtration with a commercial closed system for manufacturing ASEDs proved to be effective in ensuring sterility without any contamination over the past 4 years. This is becoming crucial, as the demand for autologous blood products for treating ocular surface disorders, such as refractory dry eyes or nonhealing defects of the corneal epithelium, is on the rise.


Asunto(s)
Contaminación de Medicamentos , Soluciones Oftálmicas , Suero , Humanos , Contaminación de Medicamentos/prevención & control , Estudios Prospectivos , Esterilización/métodos , Asepsia/métodos
8.
PDA J Pharm Sci Technol ; 78(2): 206-211, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38609149

RESUMEN

The Cell Banks, Advanced Technologies (ATMPs, NGS) session at the 2023 Viral Clearance Symposium (VCS) focused on the assurance of high virus safety profiles of advanced technology medicinal products (ATMPs) by implementation of advanced virus detection methods using rapid and sensitive technologies, such as next-generation sequencing (NGS). All presentations in this session made the need to replace in vivo testing for viruses by new technologies that have been demonstrated to be incomparably broad in their detection capabilities and can even detect unknown viruses. An evaluation of historical data collected by the Consortium on Adventitious Agent Contamination in Biomanufacturing (CAACB) from their members' in vivo and in vitro adventitious virus test experience as well as on using NGS was presented. The data convincingly supported the necessity to replace in vivo testing with faster, broader, more sensitive, more accurate, and more specific virus detection methods. Additionally, a collaborative study-initiated by the CAACB-with the goal to revisit traditional adventitious agent testing by using targeted NGS to replace in vivo and in vitro tests for well-known and broadly used Chinese hamster ovary (CHO) cells was presented, including the planned risk-assessment approach using prior knowledge and historical data. Overall, this session demonstrated that the use of new virus detection methods, such as NGS, represents a great opportunity to provide sufficient viral safety margins, specifically, for ATMPs, where downstream virus clearance is not possible. This path forward is also supported by the final ICH Q5A(R2) guideline.


Asunto(s)
Contaminación de Medicamentos , Secuenciación de Nucleótidos de Alto Rendimiento , Animales , Cricetinae , Células CHO , Cricetulus , Contaminación de Medicamentos/prevención & control , Tecnología
9.
Sci Rep ; 14(1): 9629, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671013

RESUMEN

Coronavirus disease of 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is an ongoing outbreak, disrupting human life worldwide. Vaccine development was prioritized to obtain a biological substance for combating the viral pathogen and lessening disease severity. In vaccine production, biological origin and relevant materials must be carefully examined for potential contaminants in conformity with good manufacturing practice. Due to fast mutation, several SARS-CoV-2 variants and sublineages have been identified. Currently, most of COVID-19 vaccines are developed based on the protein sequence of the Wuhan wild type strain. New vaccines specific for emerging SARS-CoV-2 strains are continuously needed to tackle the incessant evolution of the virus. Therefore, in vaccine development and production, a reliable method to identify the nature of subunit vaccines is required to avoid cross-contamination. In this study, liquid chromatography-mass spectrometry using quadrupole-time of flight along with tryptic digestion was developed for distinguishing protein materials derived from different SARS-CoV-2 strains. After analyzing the recombinantly produced receptor-binding domain (RBD) of the SARS-CoV-2 spike protein, nine characteristic peptides were identified with acceptable limits of detection. They can be used together to distinguish 14 SARS-CoV-2 strains, except Kappa and Epsilon. Plant-produced RBD-Fc protein derived from Omicron strains can be easily distinguished from the others with 4-5 unique peptides. Eventually, a peptide key was developed based on the nine peptides, offering a prompt and precise flowchart to facilitate SARS-CoV-2 strain identification in COVID-19 vaccine manufacturing.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Control de Calidad , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , SARS-CoV-2/inmunología , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Vacunas contra la COVID-19/inmunología , Humanos , Glicoproteína de la Espiga del Coronavirus/genética , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/metabolismo , COVID-19/prevención & control , COVID-19/virología , Cromatografía Liquida , Contaminación de Medicamentos/prevención & control , Espectrometría de Masas/métodos , Vacunas de Subunidad/inmunología , Cromatografía Líquida con Espectrometría de Masas
10.
J Pharm Biomed Anal ; 244: 116128, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38598924

RESUMEN

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine : 7 (1,4- butane diol) DES outperformed the betaine : 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005-100 µg g-1) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. This study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.


Asunto(s)
Disolventes Eutécticos Profundos , Contaminación de Medicamentos , Límite de Detección , Mutágenos , Contaminación de Medicamentos/prevención & control , Cromatografía de Gases/métodos , Mutágenos/análisis , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Disolventes Eutécticos Profundos/química , Disolventes Eutécticos Profundos/análisis , Tecnología Química Verde/métodos , Reproducibilidad de los Resultados , Solventes/química
11.
Phytomedicine ; 128: 155322, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38569291

RESUMEN

BACKGROUND: Species adulteration is a concern in herbal products, especially when plant substitutes of lower economic value replace valuable botanicals. Styphnolobium japonicum is well known as a potential adulterant of Ginkgo biloba, which is one of the most demanded medicinal plants due to its wide use in pharmaceuticals, food supplements, and traditional medicine. Despite bearing some resemblance to ginkgo's flavonol composition, S. japonicum lacks many of G. biloba's desired therapeutic properties. To prevent adulteration practices, it is crucial to implement rigorous quality control measures, including fast and simple diagnostic tools that can be used on-field. PURPOSE: This study aims to develop for the first time a species-specific loop-mediated isothermal amplification (LAMP) method for the fast identification of S. japonicum in ginkgo-containing products. METHODS: A set of four specific primers (SjF3, SjB3, SjFIP, and SjBIP) and loop primers (SjLF and SjLB) were designed for a LAMP based assay using the 5.8S partial sequence and the internal transcribed spacer 2 of nuclear ribosomal DNA of S. japonicum. RESULTS: The successful amplification of the LAMP assay was inspected through visual detection, with the highest intensity recorded at the optimal conditions set at 68 °C for 40 min. The primers showed high specificity and were able to accurately discriminate S. japonicum from G. biloba and 49 other species of medicinal plants. Furthermore, the proposed LAMP assay proved to be fast, selective, and highly sensitive, as demonstrated by the absolute and relative limits of detection, which were reached at 0.5 pg for S. japonicum DNA and 0.01 % S. japonicum in G. biloba, respectively. CONCLUSIONS: This novel approach allows easy identification and discrimination of S. japonicum as a potential adulterant of G. biloba, thus being a useful tool for quality control. Compared to chromatographic or PCR-based methods, the assay proved to be fast, sensitive and did not require expensive equipment, thus offering the possibly usage in field analysis.


Asunto(s)
Contaminación de Medicamentos , Ginkgo biloba , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Ginkgo biloba/química , Técnicas de Amplificación de Ácido Nucleico/métodos , Contaminación de Medicamentos/prevención & control , Cartilla de ADN , ADN de Plantas/genética , Plantas Medicinales/química , Sophora japonica
12.
Int J Pharm ; 657: 124164, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38688429

RESUMEN

Liposomes are widely used in the pharmaceutical industry as drug delivery systems to increase the efficacy and reduce the off-target toxicity of active pharmaceutical ingredients (APIs). The liposomes are more complex drug delivery systems than the traditional dosage forms, and phospholipids and cholesterol are the major structural excipients. These two excipients undergo hydrolysis and/or oxidation during liposome preparation and storage, resulting in lipids hydrolyzed products (LHPs) and cholesterol oxidation products (COPs) in the final liposomal formulations. These excipient-related impurities at elevated concentrations may affect liposome stability and exert biological functions. This review focuses on LHPs and COPs, two major categories of excipient-related impurities in the liposomal formulations, and discusses factors affecting their formation, and analytical methods to determine these excipient-related impurities.


Asunto(s)
Contaminación de Medicamentos , Excipientes , Liposomas , Excipientes/química , Contaminación de Medicamentos/prevención & control , Colesterol/química , Hidrólisis , Fosfolípidos/química , Oxidación-Reducción , Química Farmacéutica/métodos , Estabilidad de Medicamentos
13.
Daru ; 32(1): 461-468, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38613658

RESUMEN

PURPOSE: A pharmacopoeia is a compendium of guidelines and criteria for drug quality. It was established by a national or regional entity and has legal significance. This applies to administration of drugs in a particular nation or region. METHOD: In this study, the differences and similarities of microbiological acceptance criteria, specifications for microbial enumeration of herbal drugs and herbal drug preparations in 14 national and international pharmacopeias were investigated. RESULTS: It was found that 12 pharmacopeias have given separate microbial limits for total aerobic microbial count (TAMC) and total yeast and mold count (TYMC), and a list of specified microorganisms for which acceptance criteria are defined. However, similarities were noticed in Ph.Eur, Ph. Helv and, BP. Salmonella, and Escherichia coli are the most common pathogens specified for herbal preparations in which boiling water is added prior to use and for internal use in all Pharmacopoeias because they serve as indicators of potential contamination. CONCLUSION: From this study, it can be concluded that the differences in microbial limit tests and their acceptance criteria as specified in the various pharmacopoeias need to be harmonized. It will become a more convenient option for global drug manufacturers to import/export herbal drugs, and this would also eliminate the burden of performing various analytical methods and comply with different microbial acceptance criteria set by various pharmacopoeias. The comparative data obtained from this study will be used to develop strategies for revisions of pharmacopoeias in a harmonized manner with respect to microbiological acceptance criteria, specifications for microbial enumeration of herbal drugs and herbal drug preparations.


Asunto(s)
Contaminación de Medicamentos , Farmacopeas como Asunto , Preparaciones de Plantas , Preparaciones de Plantas/normas , Contaminación de Medicamentos/prevención & control , Farmacopeas como Asunto/normas , Recuento de Colonia Microbiana , Control de Calidad , Humanos
14.
Pharm Res ; 41(5): 983-1006, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38561580

RESUMEN

OBJECTIVE: This research aims to elucidate critical impurities in process validation batches of tacrolimus injection formulations, focusing on identification and characterization of previously unreported impurity at RRT 0.42, identified as the tacrolimus alcohol adduct. The potential root causes for the formation of new impurity was determined using structured risk assessment by cause and effect fishbone diagram. The primary objective was to propose mitigation plan and demonstrate the control of impurities with 6 month accelerated stability results in development batches. METHODS: The investigation utilizes method validation and characterization studies to affirm the accuracy of quantifying the tacrolimus alcohol adduct. The research methodology employed different characterization techniques like rotational rheometer, ICP‒MS, MALDI-MS, 1H NMR, 13C NMR, and DEPT-135 NMR for structural elucidation. Additionally, the exact mass of the impurity is validated using electrospray ionization mass spectra. RESULTS: Results indicate successful identification and characterization of the tacrolimus alcohol adduct. The study further explores the transformation of Tacrolimus monohydrate under various conditions, unveiling the formation of Tacrolimus hydroxy acid and proposing the existence of a novel degradation product, the Tacrolimus alcohol adduct. Six-month data from development lots utilizing Manufacturing Process II demonstrate significantly lower levels of alcohol adducts. CONCLUSIONS: Manufacturing Process II, selectively locates Tacrolimus within the micellar core of HCO-60, this prevent direct contact of ethanol with Tacrolimus which minimizes impurity alcohol adduct formation. This research contributes to the understanding of tacrolimus formulations, offering ways to safeguard product integrity and stability during manufacturing and storage.


Asunto(s)
Contaminación de Medicamentos , Inmunosupresores , Tacrolimus , Contaminación de Medicamentos/prevención & control , Tacrolimus/química , Tacrolimus/análisis , Inmunosupresores/química , Inmunosupresores/análisis , Estabilidad de Medicamentos , Alcoholes/química , Alcoholes/análisis , Composición de Medicamentos/métodos , Espectroscopía de Resonancia Magnética/métodos
15.
Sci Rep ; 14(1): 5933, 2024 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-38467674

RESUMEN

Plastic components are essential in the pharmaceutical industry, encompassing container closure systems, laboratory handling equipment, and single-use systems. As part of their material qualification process, studies on interactions between plastic contact materials and process solutions or drug products are conducted. The assessment of single-use systems includes their potential impact on patient safety, product quality, and process performance. This is particularly crucial in cell and gene therapy applications since interactions with the plastic contact material may result in an adverse effect on the isolated therapeutic human cells. We utilized the cell painting assay (CPA), a non-targeted method, for profiling the morphological characteristics of U2OS human osteosarcoma cells in contact with chemicals related to plastic contact materials. Specifically, we conducted a comprehensive analysis of 45 common plastic extractables, and two extracts from single-use systems. Results of the CPA are compared with a standard cytotoxicity assay, an osteogenesis differentiation assay, and in silico toxicity predictions. The findings of this feasibility study demonstrate that the device extracts and most of the tested compounds do not evoke any measurable biological changes on the cells (induction ≤ 5%) among the 579 cell features measured at concentrations ≤ 50 µM. CPA can serve as an important assay to reveal unique information not accessible through quantitative structure-activity relationship analysis and vice versa. The results highlight the need for a combination of in vitro and in silico methods in a comprehensive assessment of single-use equipment utilized in advanced therapy medicinal products manufacturing.


Asunto(s)
Productos Biológicos , Embalaje de Medicamentos , Humanos , Industria Farmacéutica , Seguridad del Paciente , Proyectos de Investigación , Contaminación de Medicamentos/prevención & control , Preparaciones Farmacéuticas
16.
J Pharm Sci ; 113(6): 1682-1688, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38325736

RESUMEN

This study addresses the identification of undesirable microorganisms (MOs) recovered during the environmental monitoring in manufacture of sterile medicinal products. We developed a methodology evaluation based on a decision tree; then, such approach was applied to hypothetical scenarios of uncommon MOs isolation in sterile drugs production settings. The scenarios were formulated on the basis of our field experience, in terms of both MOs selection and types of sampling site. The MOs were chosen in order to include emerging pathogens and MOs responsible for drug recall, and several sampling sites were considered for their detection (air, surfaces, and personnel). The classification of the unusual MOs revealed that most of them were undesirable, because they represented the loss of environmental control or a potential impact on the quality of the product. In some cases, the uncommon MOs were not considered as undesirable. Therefore, our results demonstrated the importance of a methodology, also in terms of recovery rate of unusual MOs and of the threshold probability for the unacceptability (e.g., 1% or 5%). The proposed methodology allowed an easy and documented evaluation for the undesirable MOs isolated from the environment of the analyzed settings for sterile drugs production.


Asunto(s)
Contaminación de Medicamentos , Contaminación de Medicamentos/prevención & control , Monitoreo del Ambiente/métodos , Esterilización/métodos , Industria Farmacéutica/métodos , Bacterias/aislamiento & purificación , Bacterias/metabolismo , Árboles de Decisión , Microbiología Ambiental
17.
J Pharm Biomed Anal ; 241: 115985, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38301578

RESUMEN

Leachables are substances that are leached from a medical device during its clinical use and are important due to the patient health-related effects they may have. Thus, medical devices are profiled for leachables (and/or extractables as probable leachables) to assess their potential impact on patient health and safety. This profiling is accomplished by screening extracts or leachates of the medical device for released organic substances via non-targeted analysis (NTA) employing chromatographic methods coupled with mass spectrometric detection. Chromatographic mass spectral response factors (RFs) for extractables and leachables vary significantly from compound to compound, complicating the quantitation of these compounds and the application of assessment strategies such as the Analytical Evaluation Threshold (AET). The analytical uncertainty resulting from response factor variation can be expressed in terms of an uncertainty factor (UF), which estimates the magnitude of response factor variation. This manuscript discusses the concept and impact of analytical uncertainty and provides best practice recommendations for the calculation and use of the uncertainty factor, UF.


Asunto(s)
Contaminación de Medicamentos , Embalaje de Medicamentos , Humanos , Incertidumbre , Espectrometría de Masas , Contaminación de Medicamentos/prevención & control , Preparaciones Farmacéuticas
18.
J Pharm Sci ; 113(6): 1597-1606, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38253223

RESUMEN

The detection of nitrosamine impurities, particularly small dialkyl types, which are frequently known to be potent mutagenic carcinogens, in some Sartan group active pharmaceutical ingredients (APIs) and finished drug products caused global regulatory organizations to have concerns. Accordingly, Registration Holders/Applicants, API manufacturers, and their raw material suppliers are required to check the presence of nitrosamines in their products and carry out risk assessments using the quality risk management principles specified in the ICH Q9 guide. In this context, a new LC-MS/MS method has been developed and validated for the simultaneous determination of NDMA, NDEA, NMBA, NDIPA, NEIPA, NDBA, and MeNP nitrosamine compounds in API and finished products as well as in primary packaging materials, one of the risk sources. This validated method was applied to check the nitrosamine content may occur from canister, blister, printed aluminum foil, nasal spray, and eye drop packaging materials as part of the Extractables & Leachables studies arising from interactions between the product and the primary packaging. For the determination and quality control of nitrosamines in sartan group pharmaceutical products and packaging materials, the developed LC-MS/MS analytical method offers highly reliable, fast, high accuracy, good sensitivity and simultaneous detection even at low concentrations.


Asunto(s)
Contaminación de Medicamentos , Embalaje de Medicamentos , Nitrosaminas , Espectrometría de Masas en Tándem , Nitrosaminas/análisis , Espectrometría de Masas en Tándem/métodos , Embalaje de Medicamentos/métodos , Medición de Riesgo/métodos , Cromatografía Liquida/métodos , Contaminación de Medicamentos/prevención & control , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Cromatografía Líquida con Espectrometría de Masas
19.
J Pharm Sci ; 113(3): 513-522, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38176455

RESUMEN

Over the past decade, Cell and Gene Therapies (C>) have been an emerging therapeutic area with more than twenty C> drug products approved and over 1000 registered trials. The remarkable progress in these modalities brings new challenges for scientists who evaluate manufacturing and storage materials, including risk assessments for extractables and leachables (E&L). Establishing a business process to qualify materials for these applications is an important risk mitigation strategy in support of these assessments. Process validation verifying process performance and product quality requirements using qualified materials also ensures that leachables from the materials do not result in an impact to process and product. The authors provide an overview of available guidelines and publications relevant to E&L risk assessments that can be used to support ex vivo C> products, highlighting gaps and standardization needs in the areas of biocompatibility and extractables conditions. Finally, the authors present leachable testing strategies, relevant to the specific manufacturing and storage conditions of C> products, and safety assessment considerations for organic and inorganic chemical entities.


Asunto(s)
Contaminación de Medicamentos , Embalaje de Medicamentos , Contaminación de Medicamentos/prevención & control , Medición de Riesgo , Proteínas , Preparaciones Farmacéuticas
20.
Talanta ; 271: 125604, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38219318

RESUMEN

Along with the United States Pharmacopeia (USP) chapters 232 and 233 regarding elemental impurities in pharmaceutical products, new challenges have been imposed in terms of sample preparation procedures prior to inductively coupled plasma mass spectrometry analysis, considering the matrix complexities. As so, a new microextraction procedure assisted by ultrasound using a cup-horn sonoreactor, minimal reactants, and sample was proposed and validated according to USP. The procedure was optimized with samples of milled tablets and 3 different acid mixtures (HNO3, 3HNO3:1HCl, and 9HNO3:1HF) and it was compared with microwave-assisted acid digestion. In the validation step, recoveries ranging from 85 to 120 % and RSD below 10 % were obtained for 22 analytes (except Ag and Pt) with satisfactory linearity and good sensitivity. The method was then applied for 37 samples of antidepressants, which presented trace levels of As, Ba, Cd, Co, Cr, Cu, Ni, Pb, Pd, Sn, and V.


Asunto(s)
Contaminación de Medicamentos , Oligoelementos , Espectrometría de Masas/métodos , Contaminación de Medicamentos/prevención & control , Análisis Espectral , Comprimidos , Microondas , Oligoelementos/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA