Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 831
Filtrar
1.
Int J Mol Sci ; 25(15)2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39125757

RESUMEN

Porphyromonas gingivalis is the most pathogenic periodontal bacterium in the world. Recently, P. gingivalis has been considered responsible for dysbiosis during the development of periodontitis. This study aimed to evaluate a novel immunochromatographic device using monoclonal antibodies against P. gingivalis in subgingival plaques. A total of 72 patients with chronic periodontitis and 53 periodontally healthy volunteers underwent clinical and microbiological examinations. Subgingival plaque samples were analyzed for the presence of P. gingivalis and compared using real-time polymerase chain reaction (PCR). In the periodontitis group, a significant positive correlation was observed between the test device scores and the real-time PCR results. The specificity, positive predictive value, negative predictive value, and accuracy of the test device for P. gingivalis, as determined by real-time PCR, were 98%, 94%, 89%, and 90%, respectively. There were significant differences in bacterial counts by real-time PCR among the groups with different ranges of device scores. Additionally, there was a significant positive correlation between the device scores for P. gingivalis and periodontal parameters. These results suggest that this novel immunochromatographic device can be effectively used for rapid detection and semi-quantification of P. gingivalis in subgingival plaques.


Asunto(s)
Cromatografía de Afinidad , Porphyromonas gingivalis , Humanos , Porphyromonas gingivalis/aislamiento & purificación , Porphyromonas gingivalis/inmunología , Masculino , Femenino , Persona de Mediana Edad , Adulto , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Enfermedades Periodontales/microbiología , Enfermedades Periodontales/diagnóstico , Placa Dental/microbiología , Periodontitis Crónica/microbiología , Periodontitis Crónica/diagnóstico , Sensibilidad y Especificidad
2.
Anal Chim Acta ; 1320: 343006, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39142783

RESUMEN

BACKGROUND: Salmonella, a foodborne pathogen poses significant threats to food safety and human health. Immunochromatographic (ICTS) sensors have gained popularity in the field of food safety due to their convenience, speed, and cost-effectiveness. However, most existing ICTS sensors rely on antibody sandwich structures which are limited by their dependence on high-quality paired antibodies and restricted sensitivity. For the first time, we combined multi-line ICTS strips with fluorescent bacterial probes to develop a label-free multi-line immunochromatographic sensor capable of detecting broad-spectrum Salmonella. Salmonella was labeled with the aggregation-induced luminescence material TCBPE, resulting in its transformation into a green fluorescent probe. RESULTS: Using this sensor, we successfully detected Salmonella typhimurium within the concentration range of 104-108 CFU/mL with a visual detection limit of 6.0 × 104 CFU/mL. Compared to single-line sensors, our multi-line sensor exhibited significantly improved fluorescence intensity resulting in enhanced detection sensitivity by 50 %. Furthermore, our developed multi-line ICTS sensor demonstrated successful detection of 18 different strains of Salmonella without any cross-reaction observed with 5 common foodborne pathogens tested. The applicability and reliability were validated using milk samples, cabbage juice samples as well and drinking water samples suggesting its potential for rapid and accurate detection of Salmonella in real-world scenarios across both the food industry and clinical settings. SIGNIFICANCE: In this experiment, we developed a TCBPE-based multiline immunochromatographic sensor. Specifically, Salmonella was labeled with the aggregation-induced luminescence material TCBPE, resulting in its transformation into a green fluorescent probe. Through the multi-line analysis system, the detection sensitivity and accuracy of the sensor are improved. In brief, the sensor does not require complex antibody labeling and paired antibodies, and only one antibody is needed to complete the detection process.


Asunto(s)
Cromatografía de Afinidad , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Leche/microbiología , Leche/química , Microbiología de Alimentos , Animales , Colorantes Fluorescentes/química , Salmonella/aislamiento & purificación , Salmonella/inmunología , Contaminación de Alimentos/análisis , Límite de Detección , Salmonella typhimurium/aislamiento & purificación , Salmonella typhimurium/inmunología , Brassica/química , Brassica/microbiología
3.
J Chromatogr A ; 1730: 465129, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38970875

RESUMEN

Therapeutic monoclonal antibodies (mAbs) are critical for treatment of a wide range of diseases. Immunoglobulin G (IgG) is the most predominant form of mAb but is prone to aggregation during production. Detection and removal of IgG aggregates are time-consuming and laborious. Chromatography is central for purification of biopharmaceuticals in general and essential in the production of mAbs. Protein purification systems are usually equipped with detectors for monitoring pH, UV absorbance, and conductivity, to facilitate optimization and control of the purification process. However, specific in-line detection of the target products and contaminating species, such as aggregates, is currently not possible using convectional techniques. Here we show a novel fiber optical in-line sensor, based on localized surface plasmon resonance (LSPR), for specific detection of IgG and IgG aggregates during affinity chromatography. A flow cell with a Protein A sensor chip was connected to the outlet of the affinity column connected to three different chromatography systems operating at lab scale to pilot scale. Samples containing various IgG concentrations and aggregate contents were analyzed in-line during purification on a Protein A column using both pH gradient and isocratic elution. Because of avidity effects, IgG aggregates showed slower dissociation kinetics than monomers after binding to the sensor chips. Possibilities to detect aggregate concentrations below 1 % and difference in aggregate content smaller than 0.3 % between samples were demonstrated. In-line detection of aggregates can circumvent time-consuming off-line analysis and facilitate automation and process intensification.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía de Afinidad , Inmunoglobulina G , Proteína Estafilocócica A , Resonancia por Plasmón de Superficie , Inmunoglobulina G/aislamiento & purificación , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Resonancia por Plasmón de Superficie/métodos , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación , Proteína Estafilocócica A/química , Agregado de Proteínas , Concentración de Iones de Hidrógeno
4.
Biosens Bioelectron ; 258: 116357, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38729049

RESUMEN

The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 °C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.


Asunto(s)
Técnicas Biosensibles , Grano Comestible , Contaminación de Alimentos , Límite de Detección , Microesferas , Micotoxinas , Zearalenona , Micotoxinas/análisis , Grano Comestible/química , Grano Comestible/microbiología , Técnicas Biosensibles/métodos , Contaminación de Alimentos/análisis , Zearalenona/análisis , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Aflatoxina B1/análisis , Aflatoxina B1/aislamiento & purificación , Tricotecenos/análisis , Tiras Reactivas/análisis , Inmunoensayo/métodos , Inmunoensayo/instrumentación , Colorantes Fluorescentes/química
5.
J Agric Food Chem ; 72(19): 11241-11250, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38709728

RESUMEN

The fungicide phenamacril has been employed to manage Fusarium and mycotoxins in crops, leading to persistent residues in the environment and plants. Detecting phenamacril is pivotal for ensuring environmental and food safety. In this study, haptens and artificial antigens were synthesized to produce antiphenamacril monoclonal antibodies (mAbs). Additionally, gold nanoparticles coated with a polydopamine shell were synthesized and conjugated with mAbs, inducing fluorescence quenching in quantum dots. Moreover, a dual-readout immunochromatographic assay that combines the positive signal from fluorescence with the negative signal from colorimetry was developed to enable sensitive and precise detection of phenamacril within 10 min, achieving detection limits of 5 ng/mL. The method's reliability was affirmed by using spiked wheat flour samples, achieving a limit of quantitation of 0.05 mg/kg. This analytical platform demonstrates high sensitivity, outstanding accuracy, and robust tolerance to matrix effects, making it suitable for the rapid, onsite, quantitative screening of phenamacril residues.


Asunto(s)
Colorimetría , Contaminación de Alimentos , Fungicidas Industriales , Residuos de Plaguicidas , Fungicidas Industriales/análisis , Contaminación de Alimentos/análisis , Colorimetría/métodos , Residuos de Plaguicidas/análisis , Anticuerpos Monoclonales/química , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Fluorescencia , Triticum/química , Nanopartículas del Metal/química , Oro/química , Límite de Detección , Harina/análisis
6.
J Agric Food Chem ; 72(20): 11794-11803, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38739902

RESUMEN

High-performance liquid chromatography with ultraviolet detection (HPLC-UV) is a common analysis technique due to its high versatility and simple operation. In the present study, HPLC-UV detection was integrated with immunoaffinity cleanup (IAC) of the sample extracts. The matrix effect was greatly reduced, and the limit of detection was as low as 1 ng/g of free abscisic acid (ABA) in fresh plant tissues. A monoclonal antibody 3F1 (mAb 3F1) was developed to specifically recognize free ABA but not ABA analogues. The mAb 3F1-immobilized immunoaffinity column exhibited a capacity of 850 ng/mL and an elution efficiency of 88.8-105% for standards. The extraction recoveries of the column for ABA ranged from 80.4 to 108.9%. ABA content was detected in various plant samples with IAC-HPLC-UV. The results were verified with ultraperformance liquid chromatography-electrospray tandem mass spectrometry. IAC-HPLC-UV can be a sensitive and cost-efficient method for plant hormone analysis.


Asunto(s)
Ácido Abscísico , Cromatografía de Afinidad , Reguladores del Crecimiento de las Plantas , Ácido Abscísico/análisis , Cromatografía Líquida de Alta Presión/métodos , Reguladores del Crecimiento de las Plantas/análisis , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Anticuerpos Monoclonales/química , Espectrometría de Masas en Tándem/métodos
7.
Artículo en Inglés | MEDLINE | ID: mdl-38705749

RESUMEN

INTRODUCTION: Pneumococcal bacteraemia is a major contributor to global morbidity and mortality. Traditional culture-based methods lack sensitivity and are time-consuming. This study aimed to assess the effectiveness of two culture-independent assays, the MALDI-TOF-MS Sepsityper® module and the lateral flow inmunochromatography test (LFICT) with the Standard F® Streptococcus pneumoniae, directly from positive blood culture (BC) bottles. METHODS: A prospective study was conducted from December 2021 to July 2022. For all BC positives for S. pneumoniae a double centrifugation protocol was implemented. The resulting pellet was subsequently processed using both techniques. RESULTS: The LFICT showed exceptional performance with 100% sensitivity and specificity, outperforming the MALDI-TOF-MS Sepsityper® module, which achieved 85.2% sensitivity and 100% specificity. Nevertheless, the combination of these assays offers a robust and comprehensive approach to diagnosis. CONCLUSIONS: The simultaneous use of both techniques offers a promising alternative that can be integrated into routine practices directly from BC samples.


Asunto(s)
Bacteriemia , Infecciones Neumocócicas , Sensibilidad y Especificidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Streptococcus pneumoniae , Humanos , Bacteriemia/diagnóstico , Bacteriemia/microbiología , Estudios Prospectivos , Infecciones Neumocócicas/diagnóstico , Infecciones Neumocócicas/microbiología , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Streptococcus pneumoniae/aislamiento & purificación , Cultivo de Sangre/instrumentación , Cultivo de Sangre/métodos , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Técnicas Bacteriológicas/métodos
8.
Food Chem ; 450: 139372, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-38640545

RESUMEN

Based on the size and surface properties of dimethomorph and flumorph, we used a computer simulation-assisted size exclusion hapten design strategy to develop group-specific monoclonal antibodies that can simultaneously recognize dimethomorph and flumorph. For this, we performed quantitative and visual semi-quantitative time-resolved fluorescence immunochromatography (TRFICA) to simultaneously detect dimethomorph and flumorph in potatoes and apples. In potato samples, the visual limit of detection (vLOD) for dimethomorph and flumorph was 4 ng/mL and 8 ng/mL, respectively, whereas the quantitative limit of detection (qLOD) for dimethomorph and flumorph was 0.26 and 0.33 ng/mL, respectively. The vLOD of dimethomorph and flumorph in apple samples was 8 ng/mL, whereas the qLOD of dimethomorph and flumorph was 0.17 and 0.38 ng/mL, respectively. The average recovery of potato and apple samples ranged from 77.5% to 121.7%, which indicated that the method can be used to rapidly detect dimethomorph and flumorph in food samples.


Asunto(s)
Cromatografía de Afinidad , Contaminación de Alimentos , Haptenos , Malus , Solanum tuberosum , Solanum tuberosum/química , Haptenos/química , Malus/química , Contaminación de Alimentos/análisis , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Anticuerpos Monoclonales/química , Límite de Detección , Fungicidas Industriales/análisis
9.
Biotechnol Bioeng ; 121(6): 1859-1875, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38470343

RESUMEN

Downstream processing is the bottleneck in the continuous manufacturing of monoclonal antibodies (mAbs). To overcome throughput limitations, two different continuous processes with a novel convective diffusive protein A membrane adsorber (MA) were investigated: the rapid cycling parallel multi-column chromatography (RC-PMCC) process and the rapid cycling simulated moving bed (RC-BioSMB) process. First, breakthrough curve experiments were performed to investigate the influence of the flow rate on the mAb dynamic binding capacity and to calculate the duration of the loading steps. In addition, customized control software was developed for an automated MA exchange in case of pressure increase due to membrane fouling to enable robust, uninterrupted, and continuous processing. Both processes were performed for 4 days with 0.61 g L-1 mAb-containing filtrate and process performance, product purity, productivity, and buffer consumption were compared. The mAb was recovered with a yield of approximately 90% and productivities of 1010 g L-1 d-1 (RC-PMCC) and 574 g L-1 d-1 (RC-BioSMB). At the same time, high removal of process-related impurities was achieved with both processes, whereas the buffer consumption was lower for the RC-BioSMB process. Finally, the attainable productivity for perfusion bioreactors of different sizes with suitable MA sizes was calculated to demonstrate the potential to operate both processes on a manufacturing scale with bioreactor volumes of up to 2000 L.


Asunto(s)
Anticuerpos Monoclonales , Cricetulus , Membranas Artificiales , Anticuerpos Monoclonales/aislamiento & purificación , Anticuerpos Monoclonales/química , Adsorción , Células CHO , Reactores Biológicos , Proteína Estafilocócica A/química , Animales , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación
10.
Acta Trop ; 254: 107181, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38503365

RESUMEN

The POC-CCA test is subject to variations in reading interpretations depending on the intensity of its results, and trace test reading have implications for determining prevalence. The aim of this study was to assess whether the readings obtained from the POC-CCA tests, conducted using a semi-quantitative scale (the G-score classification for test determination), exhibited concurrence with the direct visual interpretation (positive, negative, or trace) performed by two distinct analysts, using photographs from previously performed POC-CCA test carried out in the municipality of Maruim, in the state of Sergipe-Brazil, a region of high endemicity. The devices used to read the photographs were smartphones, so as to simulate field usage, and a desktop, a tool with higher image quality that would help the researchers in the evaluation and establishment of the final result at a later. In direct visual interpretation of the POC-CCA photographs, the most discordant results occurred in the identification of the trace response (T). The Kappa index established for the direct visual interpretation between the two analysts, in which T is considered as positive, in the desktop was κ=0.826 and in the smartphone, κ=0.950. When we use the G-score as a reading standardization technique and classify the results according to the manufacturer, with trace being evaluated as positive, the highest level of agreement was obtained. Some disagreement remains between the direct visual interpretation and the G-score when performed on the desktop, with more individuals being classified as negative in the direct visual interpretation, by both analysts. However, this result was not statistically significant. The use of the G-score scale proved to be an excellent tool for standardizing the readings and classifying the results according to the semi-quantitative scale showed greater concordance of results both among analysts and among the different devices used to view the photographs.


Asunto(s)
Cromatografía de Afinidad , Brasil/epidemiología , Humanos , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Esquistosomiasis mansoni/diagnóstico , Esquistosomiasis mansoni/epidemiología , Heces/parasitología , Animales , Sensibilidad y Especificidad , Enfermedades Endémicas
11.
J Chromatogr A ; 1698: 463982, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37087858

RESUMEN

In the biopharmaceutical industry, chromatography resins have a finite number of uses before they start to age and degrade, typically due to losses of ligand integrity and/or density. The "health" of a column is predicted and validated by running multiple cycles on representative scale-down models and can be followed by real-time on-going validation during commercial production. Principal Component Analysis (PCA), Partial Least Square (PLS), Similarity Scores and Single One Point-MultiParameter Technique (SOP-MPT) along with machine learning principles were applied to explore the hypothesis that there is predictive capability of latent variables in chromatography absorbance profiles for process performance (step yield) and product quality (aggregates, fragments, host cell proteins (HCP) and DNA, and Protein A ligand). The first stage of this study is described in this paper: a MabSelect SuRe™ chromatography column was cycled with a method to establish the "normal" baseline for process performance and product quality, followed by runs using a harsher NaOH Cleaning in Place (CIP) procedure (with a higher NaOH concentration than that recommended by the vendor) to accelerate resin degradation. The different mathematical analytical tools correlated with resin degradation of the column (reflected in decreasing step yield and binding capacity with increasing running cycle), specifically when using the Wash, Elution and Strip phases of the chromatography method. Monomer, HCP and DNA content were not significantly impacted and therefore a correlation with product quality was inconsequential. Importantly, this work shows proof-of-concept that while more traditional methods of measuring resin integrity such as the height equivalent to a theoretical place (HETP) and Asymmetry (As) measurements could not detect changes in the integrity of the resin, PCA, PLS, Similarity Scores and SOP-MPT (to a lesser extent) applied to the absorbance data were capable of anticipating issues in the chromatography bed by identifying atypical outcomes.


Asunto(s)
Cromatografía de Afinidad , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Proteínas , Hidróxido de Sodio/química , ADN/química , Modelos Químicos
12.
Biotechnol Prog ; 39(3): e3333, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36795072

RESUMEN

In good manufacturing practice (GMP) facilities in the biopharmaceutical industry, chromatography resins are largely underutilized during purification of single drug products during clinical production. Chromatography resins are dedicated to a specific product and disposed of, after only a fraction of their lifetime due to concerns of potential product carryover from one program to another. In this study, we follow a resin lifetime methodology typically used for commercial submissions and apply it to determine the feasibility of purifying different products on a Protein A MabSelect PrismA™ resin. Three distinct monoclonal antibodies were used as model molecules. Column performance was monitored through chromatogram profiles, yield, clearance capability of selected media components, pressure and product quality. A protein carryover study was designed to demonstrate that the column cleaning procedures reduced protein carryover to safe cleanliness levels regardless of multiple product contact cycles and the order in which the mAbs are captured. Data show that up to 90 total cycles (30 cycles per antibody), there was negligible protein carryover and impact on process performance. Product quality was consistent, with the only meaningful trends found for the leached Protein A ligand, without affecting the conclusion of the study. While the study was restricted to three antibodies, the proof of concept for resin reuse was demonstrated.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía de Afinidad , Equipo Reutilizado , Proteína Estafilocócica A , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/aislamiento & purificación , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Estudios de Factibilidad , Inmunoglobulina G/inmunología , Proteína Estafilocócica A/inmunología , Ligandos , Medición de Riesgo
13.
Braz. J. Pharm. Sci. (Online) ; 59: e20555, 2023. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1429956

RESUMEN

Abstract Cannabis sativa L. is one of the most consumed drugs in the world and recent studies have associated its use with an increase in the number of traffic accidents in different countries. In many countries, like Brazil, simple and reliable methodologies are still needed for the detection of drugs on site, mainly cannabinoids, considering its prevalence of use and oral fluid (OF) has been proved as an appropriate biological matrix for this purpose. Considering that, this work aims to review previous studies on immunochromatographic devices for on-site detection of cannabinoids in OF, discussing their sensitivity, specificity, cut-offs values and confirmatory methods. This data shows the importance of choosing a screening device and it reinforces the need for its implementation in Brazil. The research was conducted on 5 databases and all original articles, published in the last 10 years, were selected. A total of 32 articles were found, providing data for 17 screening devices of distinct brands. Only 2 screening devices showed satisfactory sensitivity and specificity in the evaluated studies (≥80% and ≥90% respectively). However, it should be considered that the screening devices still have some limitations, such as a higher cut-off than those recommended by international guidelines (cut-off > 2 ng/mL), therefore demonstrating the need for more studies in the area and the importance of confirmatory analysis usually fulfilled by LC-MS/MS, GC-MS/MS or GC-MS. Thus, the screening analyzes should not be evaluated by itself, but in association with confirmatory results and observational traits (behavioral changes), for a better understanding of the traffic scenario


Asunto(s)
Cannabinoides/análisis , Triaje/clasificación , Cromatografía de Afinidad/instrumentación , Dronabinol/agonistas , Cannabis/efectos adversos , Accidentes de Tránsito/prevención & control , Detección de Abuso de Sustancias/instrumentación
14.
Mikrochim Acta ; 189(2): 58, 2022 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-35013820

RESUMEN

Immunochromatography testing strips (ICTs) promise to become the point-of-care test format for early diagnosis due to their convenience, low cost, and simplification. However, the insufficient signal intensity and limited sensitivity of this format hamper their application. Herein, we overcame these limitations by integrating rod-like ferric oxyhydroxide (ß-FeOOH) nanoparticles with ICTs. By varying the concentration of PEI, a one-pot, mild-temperature hydrolysis method was adapted for the synthesis and morphology regulation of ß-FeOOH nanorod. Due to the excellent enzyme-like catalytic activity toward peroxidase substrates (TMB) in the presence of hydrogen peroxide (H2O2), the ß-FeOOH nanorod in ICTs served as a signal generator and the nanozyme for signal amplification. The proof-of-concept work was performed for the detection of human chorionic gonadotropin (hCG). A two fold improvement of detection sensitivity was achieved compared to the sensitivity of conventional Au NPs-based ICTs. These results show that ß-FeOOH-based ICT has a potential application in POCT detection in clinical diagnostics.


Asunto(s)
Gonadotropina Coriónica/química , Cromatografía de Afinidad/instrumentación , Compuestos Férricos/química , Nanotubos/química , Peroxidasa/metabolismo , Cromatografía de Afinidad/métodos , Peroxidasa/química , Sensibilidad y Especificidad , Temperatura
15.
PLoS One ; 17(1): e0262312, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34995319

RESUMEN

Yellow fever is endemic in Ghana and outbreaks occur periodically. The prodromal signs due to Yellow Fever Virus (YFV) infection are non-specific, making clinical signs unreliable as the sole criteria for diagnosis. Accurate laboratory confirmation of suspected yellow fever cases is therefore vital in surveillance programs. Reporting of ELISA IgM testing results by laboratories can delay due to late arrival of samples from the collection sites as well as limited availability of ELISA kits. In this study, the diagnostic performance characteristics of a rapid immunochromatographic Standard Q Yellow Fever IgM test kit (SD Biosensor) was evaluated for the rapid diagnosis of Yellow Fever infection in Ghana. A panel of 275 sera, comprising 81 confirmed YFV positives and 194 negatives were re-tested in this study using the Standard Q Yellow Fever IgM test kit. Using the CDC/WHO Yellow Fever IgM capture ELISA as a benchmark, the sensitivity, specificity and accuracy of the Standard Q Yellow Fever test kit were 96.3%, 97.9% and 97.5%, respectively. The false positivity rate was 5.1% and there was no cross-reactivity when the Standard Q Yellow Fever test kit was tested against dengue, malaria and hepatitis B and C positive samples. In addition, inter-reader variability and invalid rate were both zero. The results indicate that the diagnostic performance of the Standard Q Yellow Fever IgM test kit on serum or plasma is comparable to the serum IgM detection by ELISA and can be used as a point of care rapid diagnostic test kit for YFV infection in endemic areas.


Asunto(s)
Técnicas Biosensibles/instrumentación , Cromatografía de Afinidad/instrumentación , Inmunoglobulina M/inmunología , Juego de Reactivos para Diagnóstico , Fiebre Amarilla/diagnóstico , Virus de la Fiebre Amarilla/inmunología , Técnicas Biosensibles/economía , Cromatografía de Afinidad/economía , Diseño de Equipo , Humanos , Inmunoglobulina M/sangre , Límite de Detección , Juego de Reactivos para Diagnóstico/economía , Factores de Tiempo , Fiebre Amarilla/sangre , Fiebre Amarilla/inmunología , Virus de la Fiebre Amarilla/aislamiento & purificación
16.
Pediatr Infect Dis J ; 41(1): 45-47, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34471083
17.
PLoS Negl Trop Dis ; 15(12): e0009891, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34882672

RESUMEN

The direct fluorescent antibody test (dFAT) using brain sample after opening the skull is the standard rabies diagnostic test in animal rabies. However, it is not feasible in many resource-limited settings. Lateral flow devices (LFD) combined with a simple sampling methodology is quicker, simpler, and less hazardous than the standard test and can be a useful tool. We conducted a prospective on-site study to evaluate the diagnostic accuracy of the LFD with the straw sampling method compared with that of the dFAT with the skull opening procedure for post-mortem canine rabies diagnosis. We collected 97 rabies-suspected animals between December 1, 2020 and March 31, 2021. Among the 97 samples, 53 and 50 cases were positive tests for dFAT and LFD, respectively. The sensitivity and specificity of LFD with straw sampling method were 94.3% (95% confidence interval [CI], 84.3-98.8%) and 100% (95% CI, 92.0-100%), respectively. The performance of LFD by the straw sampling method showed relatively high sensitivity and 100% specificity compared with that of dFAT performed on samples collected after opening the skull. This methodology can be beneficial and is a strong tool to overcome limited animal surveillance in remote areas. However, because of our limited sample size, more data using fresh samples on-site and the optimizations are urgently needed for the further implementation in endemic areas.


Asunto(s)
Encéfalo/virología , Pruebas Diagnósticas de Rutina/veterinaria , Rabia/diagnóstico , Rabia/veterinaria , Manejo de Especímenes/instrumentación , Animales , Autopsia/instrumentación , Autopsia/métodos , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Pruebas Diagnósticas de Rutina/instrumentación , Pruebas Diagnósticas de Rutina/métodos , Perros , Femenino , Pruebas Inmunológicas/métodos , Masculino , Estudios Prospectivos , Rabia/virología , Virus de la Rabia/inmunología , Sensibilidad y Especificidad
18.
Artículo en Inglés | MEDLINE | ID: mdl-34788723

RESUMEN

Immobilized metal affinity chromatography (IMAC) is a well-established technique for protein separation and purification. IMAC has been previously utilized to capture the malaria biomarker histidine-rich protein 2 (HRP2) from blood, enhancing the sensitivity of field-appropriate diagnostic tools such as lateral flow assays. However, little work has been done to translate this technique to a truly field-usable design. In this study, IMAC-functionalized cellulose membranes are created and characterized fully for future use in applied malaria diagnostics. IMAC-functionalized cellulose membranes were investigated across a range of cellulose substrates, IMAC ligands, and divalent transition metals before use in a capture and elution flowthrough workflow. Following characterization and optimization, it was found that iminodiacetic acid bound to Zn(II) was the most promising ligand-metal pair, with three available coordination sites and a molar loading capacity of 57.7 µmol of metal/cm3 of cellulose. Using these parameters, more than 99% of HRP2 was captured from a large-volume lysed blood sample in a simple flow-through assay and 89% of the captured protein was eluted from the membrane using the chelating compound ethylenediaminetetraacetic acid. Use of this enhancement protocol on an in-house HRP2 lateral flow assay (LFA) yielded a limit of detection of 7 parasites/µL, a 15.8x enhancement factor compared to traditional LFA methods.


Asunto(s)
Antígenos de Protozoos/sangre , Celulosa/química , Cromatografía de Afinidad/métodos , Malaria/diagnóstico , Pruebas en el Punto de Atención , Proteínas Protozoarias/sangre , Zinc/química , Antígenos de Protozoos/metabolismo , Cromatografía de Afinidad/instrumentación , Humanos , Ligandos , Malaria/sangre , Malaria/parasitología , Plasmodium falciparum/metabolismo , Proteínas Protozoarias/metabolismo
19.
Artículo en Inglés | MEDLINE | ID: mdl-34823097

RESUMEN

Ultrafast affinity extraction (UAE) has recently been developed and employed for measuring non-bound (or free) fractions and binding or rate constants for drugs and other targets with soluble binding agents such as serum proteins. This study examined the long-term stability of 10 mm × 2.1 mm i.d. affinity microcolumns when used in UAE at both low and high flow rates (e.g., 0.5 and 3.5 mL/min) over an extended series of injections. This stability was investigated by using immobilized human serum albumin (HSA) and samples containing the drug warfarin with or without soluble HSA as a model system. The free warfarin fractions measured at 0.5 mL/min in the presence of soluble HSA were stable up to 150 injections and changed by <10% at 3.5 mL/min. The association equilibrium constant for warfarin with HSA that was estimated by UAE at 3.5 mL/min had no significant change over 50 injections and a change of only ∼18-22% over 100-150 injections. The dissociation rate constant for warfarin from HSA was found by combining UAE results at 0.5 and 3.5 mL/min and employing a new two-point approach, with no significant changes in this value being seen even after 200 injections. The effects of extended microcolumn use on the retention time, peak width, and peak asymmetry for warfarin, and on the backpressure of the microcolumn, were also considered. These results indicated that UAE and HSA microcolumns could be used to provide consistent values for free solute fractions, binding constants, and rate constants over a large series of injections. These results should be useful in future work by providing guidelines for the assessment, further development, and use of UAE in characterizing interactions involving other drugs and binding agents in solution-based samples.


Asunto(s)
Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Humanos , Modelos Lineales , Modelos Químicos , Unión Proteica , Reproducibilidad de los Resultados , Albúmina Sérica Humana/química , Albúmina Sérica Humana/metabolismo , Factores de Tiempo , Warfarina/análisis , Warfarina/química , Warfarina/metabolismo
20.
J Chromatogr A ; 1654: 462454, 2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34407469

RESUMEN

Continuous chromatography is a promising technology for downstream processing of biopharmaceuticals. The operation of continuous processes is significantly different to batch-mode chromatography and needs comprehensive evaluation. In this work, the performances of four Protein A affinity resins were studied systematically for twin-column continuous capture processes. A model-based approach was used to evaluate the process performance (productivity and capacity utilization) under varying operation conditions, and the objective was to reveal the crucial resin properties for continuous capture. The trade-off between productivity and capacity utilization was found, and it is necessary to select appropriate resins for different feedstock and operation conditions. The capacity utilization heavily depends on mass transfer, and steep breakthrough curves are favorable for high capacity utilization. The productivity is determined by both equilibrium binding capacity and mass transfer, and the balance of feed amount and feed time is critical. Moreover, the influence of binding capacity and mass transfer on process productivity and parameter sensitivity with two important resin properties (equilibrium binding capacity qmax and effective pore diffusion coefficient De) were assessed by the model, and suitable resin parameter ranges for twin-column continuous capture were determined. The model-based approach is an effective and useful tool to evaluate the complex performance of different resins and guide the design of next-generation resins for continuous processes.


Asunto(s)
Cromatografía de Afinidad , Proteína Estafilocócica A , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/normas , Modelos Químicos , Proteína Estafilocócica A/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA