Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27.945
Filtrar
1.
J Med Case Rep ; 18(1): 251, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38741133

RESUMEN

INTRODUCTION: Evaluating isolated extremity discomfort can be challenging when initial imaging and exams provide limited information. Though subtle patient history hints often underlie occult pathologies, benign symptoms are frequently miscategorized as idiopathic. CASE PRESENTATION: We present a case of retained glass obscuring as acute calcific periarthritis on imaging. A 48-year-old White male with vague fifth metacarpophalangeal joint pain had unrevealing exams, but radiographs showed periarticular calcification concerning inflammation. Surgical exploration unexpectedly revealed an encapsulated glass fragment eroding bone. Further history uncovered a forgotten glass laceration decade prior. The foreign body was removed, resolving symptoms. DISCUSSION: This case reveals two imperative diagnostic principles for nonspecific extremity pain: (1) advanced imaging lacks specificity to differentiate inflammatory arthropathies from alternate intra-articular processes such as foreign bodies, and (2) obscure patient history questions unearth causal subtleties that direct accurate diagnosis. Though initial scans suggested acute calcific periarthritis, exhaustive revisiting of the patient's subtle decade-old glass cut proved pivotal in illuminating the underlying driver of symptoms. CONCLUSION: Our findings underscore the critical limitations of imaging and the vital role that meticulous history-taking plays in clarifying ambiguous chronic limb presentations. They spotlight the imperative of probing even distant trauma when symptoms seem disconnected from causative events. This case reinforces the comprehensive evaluation of all subtle patient clues as key in illuminating elusive extremity pain etiologies.


Asunto(s)
Calcinosis , Cuerpos Extraños , Vidrio , Humanos , Masculino , Persona de Mediana Edad , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/diagnóstico , Diagnóstico Diferencial , Articulación Metacarpofalángica/diagnóstico por imagen , Articulación Metacarpofalángica/lesiones , Periartritis/diagnóstico por imagen , Periartritis/diagnóstico , Artralgia/etiología , Radiografía
4.
J Pak Med Assoc ; 74(4): 791-793, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38751281

RESUMEN

The nasopharynx is a rare anatomical location where a foreign body may become lodged after being ingested or inhaled. We are presenting a rare case of nasopharyngeal foreign body impaction in a two-and-a-half-year-old child that had been missed for almost a year. The child presented with a history of right-sided foul-smelling nasal discharge, snoring and mouth breathing. An X-Ray soft tissue lateral view of the post-nasal space showed an irregular partially radiopaque nasopharyngeal foreign body. The removal of the foreign body was performed under general anaesthesia successfully. Foreign body impaction in the nasopharynx can easily be missed and it is important to keep this region in mind when dealing with missing inhaled or ingested foreign bodies.


Asunto(s)
Cuerpos Extraños , Nasofaringe , Humanos , Cuerpos Extraños/cirugía , Cuerpos Extraños/diagnóstico por imagen , Nasofaringe/diagnóstico por imagen , Preescolar , Masculino , Radiografía/métodos
5.
Ann Clin Lab Sci ; 54(2): 251-253, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38802149

RESUMEN

Foreign body ingestion of sharp objects can be a striking feature of psychological dysfunction with high morbidity and mortality. While the phenomenon has been reported on, primarily from a psychiatric perspective, this report will present the effects of this behavior on the intestinal system from a pathology perspective. The report is of a 43-year-old female with a past medical history of foreign object ingestion, borderline personality disorder, depression, anxiety, and prior suicidality who passed away due to bowel obstruction. Review of her history revealed an eighteen-year history of repeated foreign body ingestion with multiple surgical interventions. A particularly remarkable aspect revealed through the surgical history is the nature of the complications. They begin in 2008 with bowel perforation due to a blunt object and continue to present with perforation in the early years but show a gradual change to adhesions and obstruction as the primary concern. Her final presentation to the hospital and cause of death was due to obstruction, not perforation, even though the foreign bodies were six knives. While this case is not the only known report of foreign body ingestion, the extensive timeline and frequency allow for an examination of the gradual progression of fibrosis and adhesions within the intestines and abdominal wall, which led to the obstruction and death despite being a protective factor against further perforation.This case was presented at the annual Association of Clinical Scientists meeting (April 2-4, Jacksonville, FL).


Asunto(s)
Fibrosis , Cuerpos Extraños , Intestinos , Humanos , Femenino , Adulto , Cuerpos Extraños/complicaciones , Intestinos/patología , Intestinos/lesiones , Obstrucción Intestinal/etiología , Obstrucción Intestinal/patología , Resultado Fatal , Perforación Intestinal/etiología , Perforación Intestinal/patología , Perforación Intestinal/cirugía
6.
BMC Pediatr ; 24(1): 359, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783220

RESUMEN

BACKGROUND: Hypoxemia represents the most prevalent adverse event during flexible bronchoscopy procedures aimed at foreign body retrieval in pediatric patients; if not expeditiously managed, it carries the potential for cardiac or respiratory arrest. The specific risk factors contributing to the occurrence of hypoxemia during foreign body FB removal via bronchoscopy have yet to be definitively established. METHODS: This retrospective study included a cohort of 266 pediatric subjects from January 1, 2015, to December 31, 2022, who underwent flexible bronchoscopy for the purpose of FB extraction. In this cohort, the supraglottic airway was used to connect the anesthesia apparatus during the removal procedure. RESULTS: In total, 45 of the pediatric patients (16.9%) experienced episodes of hypoxemia during the FB removal procedure. Multivariate analysis revealed that the following factors were significantly associated with the occurrence of hypoxemia: an operation time exceeding 60 min (odds ratio [OR] 8.55; 95% confidence interval [CI] 3.82-19.13), a maximum diameter exceeding 7 mm (OR 5.03; 95% CI, 2.24-11.29), and the presence of radiological evidence indicating pneumonia (OR 2.69; 95% CI, 1.27-5.69). CONCLUSION: During flexible bronchoscopy procedures aimed at FB removal in pediatric patients, there is an increased susceptibility to hypoxemia. Factors including extended operation duration, larger FB dimensions, and radiographic evidence suggestive of pneumonia significantly contribute to a heightened risk of hypoxemia.


Asunto(s)
Broncoscopía , Cuerpos Extraños , Hipoxia , Humanos , Broncoscopía/efectos adversos , Estudios Retrospectivos , Cuerpos Extraños/complicaciones , Femenino , Masculino , Hipoxia/etiología , Niño , Preescolar , Factores de Riesgo , Lactante , Tempo Operativo , Adolescente
7.
Open Vet J ; 14(4): 1002-1011, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38808289

RESUMEN

Background: Perforating foreign bodies from the gastrointestinal tract, such as wooden skewers, are reported in the small animal literature producing inflammatory/infectious lesions in the thorax, abdomen, and musculoskeletal system, which can be life-threatening in some instances. Several imaging modalities have been used, and advanced imaging techniques have shown a great advantage in its diagnosis and pre-surgical planning. Aim: The objective of this study is to describe the computed tomographic findings in a group of seven medium to large breed dogs with perforating wooden skewers and foreign bodies migrated from the gastrointestinal tract. Methods: The medical records database was searched for dogs with a suspected diagnosis of a perforating wooden foreign body migrated from the gastrointestinal tract in which a computed tomographic study was performed. Signalment, history, and clinicopathological findings (when available) were retrieved, and the computed tomographic studies were reviewed. Results: Clinical signs vary depending on the anatomical regions affected through the perforating pathway. All foreign bodies were identified and showed a median attenuation of 79 HU, with the most common localization being the stomach followed by the jejunum. Peritoneal fat stranding surrounding the perforation site was the most frequent computed tomographic finding. The presence of peritoneal free fluid and/or gas was uncommon. Pleural effusion, pulmonary perforation, and pneumothorax were present in most of the cases with the foreign body traversing the pleural space. Pulmonary cavitary lesions were always reported when the ending tip of the wooden skewer was within the pulmonary parenchyma. Soft tissue abscessation was recognized in all cases where the ending tip was lodged in muscular or subcutaneous tissues. Conclusion: Findings supported the variability of the secondary lesions caused by this type of foreign body and the utility of computed tomography in their recognition, as well as in the identification of the wooden skewer.


Asunto(s)
Enfermedades de los Perros , Cuerpos Extraños , Tracto Gastrointestinal , Tomografía Computarizada por Rayos X , Animales , Perros , Tomografía Computarizada por Rayos X/veterinaria , Cuerpos Extraños/veterinaria , Cuerpos Extraños/diagnóstico por imagen , Masculino , Tracto Gastrointestinal/diagnóstico por imagen , Tracto Gastrointestinal/patología , Femenino , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/diagnóstico , Estudios Retrospectivos
8.
J Surg Orthop Adv ; 33(1): 26-28, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38815074

RESUMEN

When a surgical needle is lost, the protocol is to explore the surgical field and to obtain a plain radiograph if the needle cannot be located. The size of the needle that can be detected with imaging is debated. Plain-film radiographs, C-arm, and mini C-arm fluoroscopy imaging was obtained of a cadaveric hand with retained needle of varying lengths (suture sizes 4-0 - 10-0). The authors performed analyses to determine the sensitivity and specificity of the imaging modalities. There were no differences in diagnostic area under the receiver operating characteristic curve between the three modalities. For plain film, optimal cutoff for needle size was 5.2 mm (sensitivity 0.87, specificity 0.75), for C-arm 6.8 mm (sensitivity 0.84, specificity 0.87), and for mini C-arm 5.9 mm (sensitivity 0.82, specificity 0.86). In the hand, the use of C-arm fluoroscopy is as sensitive as plain-film radiography at detecting retained needles greater than 5.9 mm. (Journal of Surgical Orthopaedic Advances 33(1):026-028, 2024).


Asunto(s)
Cuerpos Extraños , Mano , Agujas , Humanos , Fluoroscopía , Cuerpos Extraños/diagnóstico por imagen , Mano/diagnóstico por imagen , Cadáver , Sensibilidad y Especificidad , Radiografía/métodos
11.
J Vet Med Sci ; 86(6): 665-669, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38710623

RESUMEN

A juvenile rough-toothed dolphin (Steno bredanensis) was live-stranded and rescued in Kanagawa Prefecture, Japan. From the results of diagnostic examinations, blood tests indicated that the dolphin was malnourished, dehydrated, and anemic. The dolphin died on sixth day of rescue despite treatment. At autopsy, 570 g of foreign material, including 34 pieces of cellophanes and plastic debris (PD), were found in the forestomach. Additional gross findings, including some endoparasitism and presence of accessory spleens were also identified. This is the first case in Japan which accidental ingestion of foreign bodies, including PD, was suspected to be the cause of death in a cetacean.


Asunto(s)
Delfines , Plásticos , Animales , Japón , Cuerpos Extraños/veterinaria , Masculino , Resultado Fatal
14.
BMC Surg ; 24(1): 161, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762478

RESUMEN

BACKGROUND: Because the cases are quite scarce, we aimed to review cases of foreign body impaction penetrating the neck through the esophagus to analyze the characteristics of these cases. The open surgery skills of the surgeon, the treatment procedure and the surgeons' experience in the rare diseases were analyzed. METHODS: We collected and analyzed all cases from 2015-2020 in our hospital. Surgical skills and procedures for fasting and anti-infection treatment were reviewed retrospectively. Follow-up was telephone communication. RESULTS: Our series included 15 cases. Tenderness in the pre-cervical site was a physical sign for screening. Thirteen cases underwent a lateral neck open surgery with the incision including the left side of neck and only two cases were incised from the right side of the neck. Pus was found 3 days after the impaction in one case, the shortest time observed in our series. The esophageal laceration was only sutured primarily in 5 cases (33.33%) among all fifteen cases. After sufficient drainage (average more than 9 days), antibiotic treatment and fasting (normally 2-3 weeks), patients gradually began to switch to solid foods from fluids after complete blood counts and confirmations from esophageal radiography result. No severe complications occurred, and all the patients have no swallowing dis-function and recovered well. CONCLUSION: Surgery should be performed as soon as possible after impaction. Lateral neck approach surgery and the therapeutic procedure described in this article are safe and effective treatments.


Asunto(s)
Esófago , Cuerpos Extraños , Cuello , Humanos , Cuerpos Extraños/cirugía , Masculino , Femenino , Adulto , Estudios Retrospectivos , Persona de Mediana Edad , Esófago/cirugía , Cuello/cirugía , Adulto Joven , Adolescente , Anciano
15.
Medicine (Baltimore) ; 103(18): e37932, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701315

RESUMEN

Angiosarcomas are rare and highly malignant soft tissue sarcomas originating from endothelial cells lining the lymphatic or vascular system. While they predominantly emerge from (sub)cutaneous regions, occurrences have been reported throughout the body. The etiology of angiosarcoma remains elusive in most clinical cases. Nevertheless, several prognosis risk factors play a pivotal role, including chronic lymphedema, therapeutic irradiation, environmental carcinogens, familial syndromes, and the presence of foreign materials like metallic objects and biomedical implants. Despite evidence implicating retained foreign material in angiosarcoma development, understanding its prognosis and pathogenesis remains limited. The pathogenesis of angiosarcoma appears to involve a complex interplay of chronic inflammation, tissue remodeling, and genetic factors that create a conducive microenvironment for malignant transformation. Management of these sarcomas remains challenging due to their infiltrative nature owing to the high chance of metastasis and local recurrence. The primary treatment modalities currently include surgery, radiotherapy, and chemotherapy, but recent advances in targeted immunotherapy and gene therapy hold promise for more effective approaches. This comprehensive review delves into the potential etiological and pathogenic roles of foreign materials, such as metallic objects, biomedical implants, and biomaterials, in the development of angiosarcoma. Further research into the underlying molecular mechanisms could provide valuable insights for tailored management and developing novel targeted therapeutic strategies.


Asunto(s)
Cuerpos Extraños , Hemangiosarcoma , Prótesis e Implantes , Humanos , Hemangiosarcoma/terapia , Hemangiosarcoma/etiología , Hemangiosarcoma/patología , Cuerpos Extraños/complicaciones , Cuerpos Extraños/terapia , Prótesis e Implantes/efectos adversos , Factores de Riesgo
16.
Ulus Travma Acil Cerrahi Derg ; 30(5): 361-369, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38738679

RESUMEN

Magnet ingestion in children can lead to serious complications, both acutely and chronically. This case report discusses the treatment approach for a case involving multiple magnet ingestions, which resulted in a jejuno-colonic fistula, segmental intestinal volvulus, hepa-tosteatosis, and renal calculus detected at a late stage. Additionally, we conducted a literature review to explore the characteristics of intestinal fistulas caused by magnet ingestion. A six-year-old girl was admitted to the Pediatric Gastroenterology Department pre-senting with intermittent abdominal pain, vomiting, and diarrhea persisting for two years. Initial differential diagnoses included celiac disease, cystic fibrosis, inflammatory bowel disease, and tuberculosis, yet the etiology remained elusive. The Pediatric Surgery team was consulted after a jejuno-colonic fistula was suspected based on magnetic resonance imaging findings. The physical examination revealed no signs of acute abdomen but showed mild abdominal distension. Subsequent upper gastrointestinal series and contrast enema graphy confirmed a jejuno-colonic fistula and segmental volvulus. The family later reported that the child had swallowed a magnet two years prior, and medical follow-up had stopped after the spontaneous expulsion of the magnets within one to two weeks. Surgical intervention was necessary to correct the volvulus and repair the large jejuno-colonic fistula. To identify relevant studies, we conducted a detailed literature search on magnet ingestion and gastrointestinal fistulas according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. We identified 44 articles encompassing 55 cases where symptoms did not manifest in the acute phase and acute abdomen was not observed. In 29 cases, the time of magnet ingestion was unknown. Among the 26 cases with a known ingestion time, the average duration until fistula detection was 22.8 days (range: 1-90 days). Fistula repairs were performed via laparotomy in 47 cases.


Asunto(s)
Fístula Intestinal , Humanos , Femenino , Fístula Intestinal/etiología , Fístula Intestinal/cirugía , Niño , Cuerpos Extraños/complicaciones , Cuerpos Extraños/cirugía , Cuerpos Extraños/diagnóstico por imagen , Imanes/efectos adversos , Síndromes de Malabsorción/etiología , Síndromes de Malabsorción/diagnóstico , Enfermedades del Yeyuno/etiología , Enfermedades del Yeyuno/cirugía , Enfermedades del Yeyuno/diagnóstico , Vólvulo Intestinal/cirugía , Vólvulo Intestinal/etiología , Vólvulo Intestinal/diagnóstico , Enfermedades del Colon/etiología , Enfermedades del Colon/cirugía
17.
Am J Case Rep ; 25: e943781, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38816969

RESUMEN

BACKGROUND Double-J (D-J) ureteric stents are widely applied in urological operations as they play a vital role in maintaining postoperative functionality of the patient's urinary system and thereby accelerating recovery. D-J stent encrustation may occur due to prolonged retention and lead to secondary complications. We report the case of a forgotten D-J stent that gradually formed into a bladder stone. CASE REPORT A 54-year-old man was referred to the Urology Department due to intermittent hematuria, left flank pain, and lower urinary tract symptoms that persisted for 2 weeks. His history was significant for undergoing left ureterolithotripsy followed by the implantation of an ipsilateral D-J stents 2 years ago in a local hospital. The patient did not follow-up regularly or actively seek medical attention for his urinary tract symptoms. Computed tomographic urography revealed a hyperdense tubular object protruding from the left distal ureter to the bladder. The patient underwent cystolithotripsy, left ureteric stent removal, and left ureteroscopy to clear away the bladder stone and its D-J stent core. CONCLUSIONS Formation of bladder stones secondary to prolonged indwelling D-J stent and its encrustation is not uncommon in developing countries where the level of public education is low. Prompt D-J stent removal can prevent complications associated with its retention and avoid unnecessary secondary procedures. Endoscopic urologic procedures are safe and feasible management options, and doctor-to-patient communication is vital for a better prognosis.


Asunto(s)
Stents , Cálculos de la Vejiga Urinaria , Humanos , Masculino , Persona de Mediana Edad , Stents/efectos adversos , Cálculos de la Vejiga Urinaria/cirugía , Cálculos de la Vejiga Urinaria/terapia , Uréter/cirugía , Remoción de Dispositivos , Cuerpos Extraños/cirugía , Ureteroscopía , Litotricia
18.
BMC Pediatr ; 24(1): 246, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582899

RESUMEN

BACKGROUND: Button battery (BB) ingestions (BBI) are increasingly prevalent in children and constitute a significant, potentially life-threatening health hazard, and thus a pediatric emergency. Ingested BBs are usually charged and can cause severe symptom within 2 h. Discharged BBs ingestion is very rare and protracted symptom trajectories complicate diagnosis. Timely imaging is all the more important. Discharged BBs pose specific hazards, such as impaction, and necessitate additional interventions. CASE PRESENTATION: We present the case of a previously healthy 19-month-old girl who was admitted to our pediatric university clinic in Germany for assessment of a three-month history of intermittent, mainly inspiratory stridor, snoring and feeding problems (swallowing, crying at the sight of food). The child's physical examination and vital signs were normal. Common infectious causes, such as bronchitis, were ruled out by normal lab results including normal infection parameters, negative serology for common respiratory viruses, and normal blood gas analysis, the absence of fever or pathological auscultation findings. The patient's history contained no evidence of an ingestion or aspiration event, no other red flags (e.g., traveling, contact to TBC). Considering this and with bronchoscopy being the gold standard for foreign body (FB) detection, an x-ray was initially deferred. A diagnostic bronchoscopy, performed to check for airway pathologies, revealed normal mucosal and anatomic findings, but a non-pulsatile bulge in the trachea. Subsequent esophagoscopy showed an undefined FB, lodged in the upper third of the otherwise intact esophagus. The FB was identified as a BB by a chest X-ray. Retrieval of the battery proved extremely difficult due to its wedged position and prolonged ingestion and required a two-stage procedure with consultation of Ear Nose Throat colleagues. Recurring stenosis and regurgitation required one-time esophageal bougienage during follow-up examinations. Since then, the child has been asymptomatic in the biannual endoscopic controls and is thriving satisfactorily. CONCLUSION: This case describes the rare and unusual case of a long-term ingested, discharged BB. It underscores the need for heightened vigilance among healthcare providers regarding the potential hazards posed by discharged BBIs in otherwise healthy children with newly, unexplained stridor and feeding problems. This case emphasizes the critical role of early diagnostic imaging and interdisciplinary interventions in ensuring timely management and preventing long-term complications associated even to discharged BBs.


Asunto(s)
Cuerpos Extraños , Femenino , Humanos , Lactante , Ingestión de Alimentos , Esofagoscopía , Esófago , Cuerpos Extraños/complicaciones , Cuerpos Extraños/diagnóstico por imagen , Ruidos Respiratorios/etiología
20.
BMJ Open Ophthalmol ; 9(1)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38565231

RESUMEN

BACKGROUND: Pterygium is a common ocular surface disorder that requires surgical intervention for treatment. Conjunctival autografts are preferred over simple excision due to lower recurrence rates. This systematic review and meta-analysis compared the modified sutureless glue-free (MSGF) method with conventional sutures (CS) for conjunctival autograft fixation in primary pterygium surgery. METHODS: A comprehensive search was conducted in MEDLINE, Embase, CENTRAL, Google Scholar and ClinicalTrials.gov for randomised controlled trials (RCTs) comparing MSGF and CS conjunctival autografts. Outcome measures included operation time, recurrence and postoperative complications. Standardised mean difference (SMD) and risk ratio (RR) were used for continuous and dichotomous outcomes, respectively. RESULTS: 11 RCTs involving 833 participants were included. The analysis revealed that MSGF had a significantly shorter operation time compared with CS (SMD -3.704, 95% CI -5.122 to -2.287, p<0.001). CS was associated with a higher risk of foreign body sensation (RR 0.22, 95% CI 0.06 to 0.74, p=0.01). MSGF was associated with a higher risk of graft dehiscence (RR 9.01, 95% CI 2.74 to 29.68, p=0.000) and graft retraction (RR 2.37, 95% CI 1.17 to 4.77, p=0.02). No significant differences were found in recurrence, graft haemorrhage, granuloma, Dellen and conjunctival oedema. CONCLUSION: Using the MSGF technique in conjunctival autograft fixation for pterygium surgery reduces operation time by relying solely on the patient's blood for fixation. However, it increases the risk of graft dehiscence and retraction. However, CS is linked to a higher likelihood of experiencing foreign body sensations. Understanding the learning curve and surgeon familiarity with novel techniques is crucial for optimising patient care and surgical outcomes, while individualised decision-making is necessary considering the advantages and disadvantages of each approach. Further research is warranted to minimise complications and optimise surgical outcomes.


Asunto(s)
Conjuntiva/anomalías , Cuerpos Extraños , Pterigion , Humanos , Pterigion/cirugía , Autoinjertos , Adhesivo de Tejido de Fibrina , Recurrencia , Conjuntiva/cirugía , Suturas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA