Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.313
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(5): 1, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691092

RESUMEN

Purpose: Elevated intraocular pressure (IOP) is thought to cause lamina cribrosa (LC) blood vessel distortions and potentially collapse, adversely affecting LC hemodynamics, reducing oxygenation, and triggering, or contributing to, glaucomatous neuropathy. We assessed the robustness of LC perfusion and oxygenation to vessel collapses. Methods: From histology, we reconstructed three-dimensional eye-specific LC vessel networks of two healthy monkey eyes. We used numerical simulations to estimate LC perfusion and from this the oxygenation. We then evaluated the effects of collapsing a fraction of LC vessels (0%-36%). The collapsed vessels were selected through three scenarios: stochastic (collapse randomly), systematic (collapse strictly by the magnitude of local experimentally determined IOP-induced compression), and mixed (a combination of stochastic and systematic). Results: LC blood flow decreased linearly as vessels collapsed-faster for stochastic and mixed scenarios and slower for the systematic one. LC regions suffering severe hypoxia (oxygen <8 mm Hg) increased proportionally to the collapsed vessels in the systematic scenario. For the stochastic and mixed scenarios, severe hypoxia did not occur until 15% of vessels collapsed. Some LC regions had higher perfusion and oxygenation as vessels collapsed elsewhere. Some severely hypoxic regions maintained normal blood flow. Results were equivalent for both networks and patterns of experimental IOP-induced compression. Conclusions: LC blood flow was sensitive to distributed vessel collapses (stochastic and mixed) and moderately vulnerable to clustered collapses (systematic). Conversely, LC oxygenation was robust to distributed vessel collapses and sensitive to clustered collapses. Locally normal flow does not imply adequate oxygenation. The actual nature of IOP-induced vessel collapse remains unknown.


Asunto(s)
Presión Intraocular , Disco Óptico , Oxígeno , Flujo Sanguíneo Regional , Animales , Presión Intraocular/fisiología , Flujo Sanguíneo Regional/fisiología , Disco Óptico/irrigación sanguínea , Hipertensión Ocular/fisiopatología , Macaca mulatta , Imagenología Tridimensional , Modelos Animales de Enfermedad
2.
Lasers Med Sci ; 39(1): 125, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38713436

RESUMEN

AIM: To detect if we can use the reduction in the optic disc vessel density as an indicator to the reduction in intracranial tension in patients with residual optic disc elevation after shunt surgery as fundus examination in those cases is not conclusive. PATIENTS AND METHOD: 21 patients with papilledema due to idiopathic intracranial hypertension underwent shunt surgery. Full neurological and ophthalmological assessments were done. The optic disc vessel density was measured before and 3 months after surgery. Patients were then divided according to the resolution of papilledema into 2 groups: 1) Residual disc elevation group. 2) Completely resolved disc edema group. CSF pressure was measured via lumber puncture preoperative for all patients and 3 months post-operative only for patients with residual disc edema. A comparison between both groups was done. RESULTS: There was a highly statistically significant difference between the two groups as regard the papilledema grade (the residual disc elevation group had a higher grade of papilledema) with P-value=0.000. As regard the difference in the preoperative optic disc vessel density between the two groups, there were statistically significant differences (optic disc vessel density was more in the residual disc elevation group). As regard the postoperative optic disc vessel density, there were non-significant differences between the two groups in whole image, inside disc and peripapillary vessel density (either in macro or microvasculature). CONCLUSION: The optic disc vessel density decreased with normal postoperative CSF opening pressure in cases with residual disc elevation postoperatively. Thus, in cases of residual optic disc swelling after shunt surgery, we can detect the reduction of intracranial pressure by the reduction in the optic disc vessel density which is a safe non-invasive technique. That may help in cases of residual disc elevation.


Asunto(s)
Disco Óptico , Papiledema , Seudotumor Cerebral , Humanos , Disco Óptico/irrigación sanguínea , Papiledema/etiología , Papiledema/cirugía , Femenino , Masculino , Adulto , Seudotumor Cerebral/cirugía , Seudotumor Cerebral/fisiopatología , Adulto Joven , Persona de Mediana Edad , Derivaciones del Líquido Cefalorraquídeo , Adolescente
3.
Transl Vis Sci Technol ; 13(5): 8, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38739084

RESUMEN

Purpose: This study aimed to evaluate the ocular characteristics associated with spontaneously high myopia in adult nonhuman primates (NHPs). Methods: A total of 537 eyes of 277 macaques with an average age of 18.53 ± 3.01 years (range = 5-26 years), raised in a controlled environment, were included. We measured ocular parameters, including spherical equivalent (SE), axial length (AXL), and intraocular pressure. The 45-degree fundus images centered on the macula and the disc assessed the fundus tessellation and parapapillary atrophy (PPA). Additionally, optical coherence tomography (OCT) was used to measure the thickness of the retinal nerve fiber layer (RNFL). Results: The mean SE was -1.58 ± 3.71 diopters (D). The mean AXL was 18.76 ± 0.86 mm. The prevalence rate of high myopia was 17.7%. As myopia aggravated, the AXL increased (r = -0.498, P < 0.001). Compared with non-high myopia, highly myopic eyes had a greater AXL (P < 0.001), less RNFL thickness (P = 0.004), a higher incidence of PPA (P < 0.001), and elevated grades of fundus tessellation (P < 0.001). The binary logistic regression was performed, which showed PPA (odds ratio [OR] = 4.924, 95% confidence interval [CI] = 2.375-10.207, P < 0.001) and higher grades of fundus tessellation (OR = 1.865, 95% CI = 1.474-2.361, P < 0.001) were independent risk characteristics for high myopia. Conclusions: In NHPs, a higher grade of fundus tessellation and PPA were significant biomarkers of high myopia. Translational Relevance: The study demonstrates adult NHPs raised in conditioned rooms have a similar prevalence and highly consistent fundus changes with human beings, which strengthens the foundation for utilizing macaques as an animal model in high myopic studies.


Asunto(s)
Fondo de Ojo , Tomografía de Coherencia Óptica , Animales , Masculino , Femenino , Modelos Animales de Enfermedad , Disco Óptico/patología , Disco Óptico/diagnóstico por imagen , Atrofia Óptica/patología , Atrofia Óptica/epidemiología , Presión Intraocular/fisiología , Miopía Degenerativa/patología , Miopía Degenerativa/epidemiología , Fibras Nerviosas/patología , Longitud Axial del Ojo/patología , Células Ganglionares de la Retina/patología , Miopía/patología , Miopía/epidemiología , Miopía/veterinaria
4.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776117

RESUMEN

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Asunto(s)
Córnea , Presión Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Córnea/diagnóstico por imagen , Córnea/fisiología , Presión Intraocular/fisiología , Fenómenos Biomecánicos/fisiología , Anciano , Persona de Mediana Edad , Esclerótica/fisiología , Esclerótica/diagnóstico por imagen , Masculino , Femenino , Glaucoma/fisiopatología , Anciano de 80 o más Años , Donantes de Tejidos , Adulto
5.
Int Ophthalmol ; 44(1): 226, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758396

RESUMEN

PURPOSE: Glaucoma and multiple sclerosis (MS) can cause optic disc pathology and, in this way, affect optical coherence tomography (OCT) data. In this context, the objective of this study is to investigate the changes in the mean, quadrant, and sector data measured by OCT in glaucoma and MS patients. METHODS: The sample of this prospective cohort study consisted of 42 MS patients (84 eyes), 34 Primary open-angle glaucomas patients (67 eyes), and 24 healthy control subjects (48 eyes). The MS group was divided into two groups according to the presence of a history of optic neuritis. Accordingly, those with a history of optic neuritis were included in the MS ON group, and those without a history of optic neuritis were included in the MS NON group. The differences between these groups in the mean, quadrant, and sector data related to the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were evaluated. RESULTS: Superior nasal (SN), superior temporal (ST), inferior nasal (IN), and superior quadrant (SUP) values were significantly lower in the glaucoma group than in the MS group (p < 0.05). The mean superior GCC (GCC SUP) value was significantly lower in the MS ON group than in the glaucoma group (p < 0.05). On the other hand, SN, ST, inferior temporal (IT), IN, average RNFL (AVE RNFL), semi-average superior RNFL (SUP AVE RNFL), semi-average inferior RNFL (INF AVE RNFL), SUP, and inferior quadrant RNFL (INF) values were significantly lower in the glaucoma group than in the MS NON group (p < 0.05). CONCLUSION: RNFL and GCC parameters get thinner in MS and glaucoma patients. While the inferior and superior RNFL quadrants are more frequently affected in glaucoma patients, the affected quadrants vary according to the presence of a history of optic neuritis in MS patients. It is noteworthy that the GCC superior quadrant was thin in MS ON patients. The findings of this study indicate that OCT data may be valuable in the differential diagnosis of glaucoma and MS.


Asunto(s)
Presión Intraocular , Esclerosis Múltiple , Fibras Nerviosas , Disco Óptico , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Femenino , Masculino , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/complicaciones , Estudios Prospectivos , Células Ganglionares de la Retina/patología , Fibras Nerviosas/patología , Disco Óptico/patología , Disco Óptico/diagnóstico por imagen , Persona de Mediana Edad , Adulto , Presión Intraocular/fisiología , Glaucoma de Ángulo Abierto/diagnóstico , Campos Visuales/fisiología , Neuritis Óptica/diagnóstico
7.
Zhonghua Yan Ke Za Zhi ; 60(5): 423-429, 2024 May 11.
Artículo en Chino | MEDLINE | ID: mdl-38706080

RESUMEN

Objective: To investigate the effect of virtual reality visual training on remodeling optic nerve structures of glaucoma patients and analyze the influencing factors of visual training effect. Methods: A prospective non-randomized controlled trial was conducted. Glaucoma patients who presented to the Department of Ophthalmology, Beijing Shijitan Hospital between October 2021 and October 2022 were collected and divided into the training group or the control group according to their intentions. The training group accepted 3 months of visual training, while the control group did not. Optical coherence tomography was used to examine the disc edge area, cup volume, disc area, cup-to-disc ratio, and other parameters of the optic disc of both eyes of the patients at enrollment and after 3 months, and the changes of each parameter in the two groups were analyzed. Multivariate analysis was performed in the training group to investigate the effects of sex, age, visual field index, and mean defect on visual disc structure changes during visual training. Results: A total of 53 glaucoma patients (101 eyes) were included in the final analysis, among which the training group consisted of 27 cases (51 eyes), with 19 males and 8 females, and the age range was 48.0 (40.0, 61.0) years old. The control group comprised 26 cases (50 eyes), with 26 males and 11 females, and the age range was 54.0 (38.0, 63.0) years old. Compared with the control group, the deviation of cup volume was -0.006(-0.050, 0.015)mm3 (P<0.05), and the deviation of disc edge area was 0.00(-0.04, 0.05)mm2 (P<0. 05)in the visual training group after 3 months of visual training. The gender (OR=4.217, 95%CI=1.188-14.966) may be the influence factor of rim area. While,the mean defect (OR=1.526, 95%CI=0.245-9.491) was not that influential on rim area change. Conclusions: Visual training can increase the disc area and decrease the optic cup volume of the optic nerve in glaucoma patients. The rim area may be increased more easily after visual training in male glaucoma patients.


Asunto(s)
Glaucoma , Disco Óptico , Tomografía de Coherencia Óptica , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Adulto , Campos Visuales
8.
BMC Ophthalmol ; 24(1): 201, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698363

RESUMEN

BACKGROUND: We aimed to employ Optical Coherence Tomography Angiography (OCTA) to comprehensively assess changes in the optic nerve head (ONH) and macular perfusion before and after the Corneal Collagen Cross-Linking (CCL) procedure in patients with keratoconus. METHODS: A total of 22 keratoconus patient's candidate for CCL procedures were included based on specific criteria, with meticulous exclusion criteria in place to minimize potential confounders. Participants underwent OCTA assessments of the ONH and macula using the Spectralis OCT (Heidelberg) before CCL, as well as at 1- and 3-months post-CCL. MATLAB software was utilized for image analysis. RESULTS: The mean age of the participants was 20.09 ± 6.11, including 59% male, and the mean intraocular pressure (IOP) before the surgery was 13.59 ± 2.85 mmHg. Peripapillary Retinal nerve fiber layer (ppRNFL) thickness and overall retinal thickness remained stable post-CCL. However, significant alterations were observed in macular vessel density, emphasizing regional variations in vascular response. For macular large vessel density (LVD), both superficial and deep vascular complex (SVC and DVC) demonstrated significant differences between before surgery and the 3 months post-surgery follow-up (p < 0.001 and p = 0.002, respectively). Optic nerve head markers demonstrated relative stability, except for changes in avascular complex density, which was 49.2 ± 2.2% before the surgery and decrease to 47.6 ± 1.7% three months after the operation (P-value = 0.005). CONCLUSION: While CCL appears to maintain the integrity of certain ocular structures, alterations in macular perfusion post-CCL suggest potential effects on retinal blood supply. Long-term monitoring is crucial to understand the implications of these changes, particularly in the context of conditions such as diabetes.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Angiografía con Fluoresceína , Queratocono , Disco Óptico , Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Queratocono/fisiopatología , Queratocono/diagnóstico , Masculino , Femenino , Colágeno/metabolismo , Adulto Joven , Adulto , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/fisiopatología , Disco Óptico/irrigación sanguínea , Adolescente , Estudios Prospectivos , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Mácula Lútea/diagnóstico por imagen , Mácula Lútea/irrigación sanguínea
9.
Am J Ophthalmol ; 259: 7-14, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38708401

RESUMEN

Purpose: To evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED). Design: Comparative diagnostic accuracy analysis by race. Participants: 379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Methods: Spectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other. Main Outcome Measures: Diagnostic accuracy of RNFLT measurements. Results: Diagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results. Conclusions: OCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Fibras Nerviosas , Disco Óptico , Curva ROC , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica , Campos Visuales , Población Blanca , Humanos , Glaucoma de Ángulo Abierto/etnología , Glaucoma de Ángulo Abierto/diagnóstico , Tomografía de Coherencia Óptica/métodos , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Femenino , Masculino , Persona de Mediana Edad , Presión Intraocular/fisiología , Campos Visuales/fisiología , Población Blanca/etnología , Reproducibilidad de los Resultados , Anciano , Disco Óptico/patología , Disco Óptico/diagnóstico por imagen , Enfermedades del Nervio Óptico/diagnóstico , Enfermedades del Nervio Óptico/etnología , Negro o Afroamericano/etnología , Área Bajo la Curva , Sensibilidad y Especificidad
10.
Invest Ophthalmol Vis Sci ; 65(5): 25, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758640

RESUMEN

Purpose: To quantitatively characterize retinal changes across different quantiles of refractive error in 34,414 normal eyes of 23,064 healthy adults in the UK Biobank. Methods: Twelve optic disc (OD), foveal and vascular parameters were derived from color fundus photographs, correcting for ocular magnification as appropriate. Quantile regression was used to test the independent associations between these parameters and spherical equivalent refraction (SER) across 34 refractive quantiles (high hyperopia to high myopia)-controlling for age, sex and corneal radius. Results: More negative SER was nonlinearly associated with greater Euclidian (largely horizontal) OD-fovea distance, larger OD, less circular OD, more obliquely orientated OD (superior pole tilted towards the fovea), brighter fovea, lower vascular complexity, less tortuous vessels, more concave (straightened out towards the fovea) papillomacular arterial/venous arcade and wider central retinal arterioles/venules. In myopia, these parameters varied more strongly with SER as myopia increased. For example, while every standard deviation (SD) decrease in vascular complexity was associated with 0.63 D (right eye: 95% confidence interval [CI], 0.58-0.68) to 0.68 D (left eye: 95% CI, 0.63-0.73) higher myopia in the quantile corresponding to -0.60 D, it was associated with 1.61 D (right eye: 95% CI, 1.40-1.82) to 1.70 D (left eye: 95% CI, 1.56-1.84) higher myopia in the most myopic quantile. OD-fovea angle (degree of vertical separation between OD and fovea) was found to vary linearly with SER, but the magnitude was of little practical importance (less than 0.10 D variation per SD change in angle in almost all refractive quantiles) compared with the changes in OD-fovea distance. Conclusions: Several interrelated retinal changes indicative of an increasing (nonconstant) rate of mechanical stretching are evident at the posterior pole as myopia increases. These changes also suggest that the posterior pole stretches predominantly in the temporal horizontal direction.


Asunto(s)
Hiperopía , Miopía , Refracción Ocular , Humanos , Masculino , Hiperopía/fisiopatología , Femenino , Miopía/fisiopatología , Refracción Ocular/fisiología , Persona de Mediana Edad , Adulto , Vasos Retinianos/fisiopatología , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Anciano , Disco Óptico/irrigación sanguínea , Fóvea Central/diagnóstico por imagen , Fóvea Central/patología , Agudeza Visual/fisiología
11.
BMJ Case Rep ; 17(5)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38749525

RESUMEN

A man in his 80s, with a history of diabetes, hypertension and coronary artery disease, presented with bilateral painless progressive vision loss 2 years prior. His examination showed subnormal best corrected visual acuity of 20/50 and 20/80 in the right eye and left eye (LE), respectively, grade II relative afferent pupillary defect in LE, normal anterior segment, intra-ocular pressure (IOP) and defective colour vision in both eyes (BE). Fundus examination revealed optic disc pallor, disc collaterals and grade 2 hypertensive retinopathy in BE. Automated perimetry showed advanced field loss in BE. MRI of the brain and orbits with contrast showed signs of raised intracranial pressure, and magnetic resonance angiogram of the brain showed multiple arterio-venous channels along with the right transverse and sigmoid sinuses. The patient was referred to a neuroradiologist for further evaluation, and cerebral angiogram confirmed multifocal high-flow dural arterio-venous fistulae at right jugular foramen, transverse and sigmoid sinuses. He underwent Onyx liquid embolization.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Embolización Terapéutica , Disco Óptico , Humanos , Masculino , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Malformaciones Vasculares del Sistema Nervioso Central/complicaciones , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico , Embolización Terapéutica/métodos , Disco Óptico/irrigación sanguínea , Disco Óptico/diagnóstico por imagen , Anciano de 80 o más Años , Angiografía Cerebral , Angiografía por Resonancia Magnética , Diagnóstico Diferencial , Imagen por Resonancia Magnética
12.
Invest Ophthalmol Vis Sci ; 65(4): 7, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38564193

RESUMEN

Purpose: This study investigates the temporal relationship between blood flow changes and alterations in retinal nerve fiber layer thickness (RNFLT) and mean deviation (MD) in individuals with glaucoma. Methods: Blood flow, measured by mean blur rate in optic nerve head vessels (MBRv) and tissues (MBRt) using laser speckle flowgraphy (LSFG)-NAVI, was analyzed using structural equation models (SEMs). SEMs assessed whether the previous rate of one parameter predicted the current rate of the other parameter, adjusted for its own rate in the previous time interval. Data from 345 eyes of 174 participants were gathered from visits every six months. Results: Rates of change of both MBRv and MBRt were significantly predicted by their own rate in the previous time interval and by the rate of change of MD in the previous time interval (P < 0.001 and P = 0.043, respectively), but not by the rate of MD in the concurrent interval (P = 0.947 and P = 0.549), implying that changes in MD precede changes in blood flow. Rates of change of RNFLT were predicted by their own previous rate and the rate of change of MBRv and MBRt in either the previous interval (P = 0.002 and P = 0.008) or the concurrent interval (P = 0.001 and P = 0.018), suggesting that MBR may change before RNFLT. Conclusions: The evidence supports a temporal sequence where MD changes precede blood flow changes, which, in turn, may precede alterations in RNFLT.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Campos Visuales , Retina , Fibras Nerviosas
13.
Z Psychosom Med Psychother ; 70(1): 24-34, 2024 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-38598705

RESUMEN

OBJECTIVES: To investigate macular and peripapillary vascular density (VD) in patients with anorexia nervosa (AN) compared to healthy controls. Methods:Whole face scans of the superficial and deep macular layers and whole face and peripapillary scans of the radial peripapillary capillaries (RPC) were obtained using optical coherence tomography angiography (OCTA, AngioVueR, Optovue) in ten patients with AN and ten age-matched controls.The primary objective was to determine whether there was a difference between the vessel density (VD) in the above areas in AN and controls. P-values ≤ 0.0125 were considered statistically significant. Results: VD in the superficialmacular en-face OCTA image was significantly lower in the study group compared to the control group. Neither the deepmacula nor the radial peripapillary capillary (RPC) in the whole-face image nor the RPC-peripapillary imaging appeared to be significantly different. Conclusion: Patients with AN showed reduced VD in the superficialmacular layers compared to healthy controls, which can be discussed as a consequence of the malnutrition. OCTA could be a useful non- invasive tool to detect reduced peripheral blood supply to show vascular changes that occur before ocular symptoms.


Asunto(s)
Anorexia Nerviosa , Disco Óptico , Humanos , Disco Óptico/irrigación sanguínea , Angiografía con Fluoresceína/métodos , Vasos Retinianos , Densidad Microvascular , Proyectos Piloto , Tomografía de Coherencia Óptica/métodos , Anorexia Nerviosa/diagnóstico
14.
Int Ophthalmol ; 44(1): 181, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625618

RESUMEN

PURPOSE: To assess ocular blood flow (OBF) changes in patients with neovascular age-related macular degeneration (nAMD) treated with intravitreal injections of ranibizumab biosimilar (IVRbs) or brolucizumab (IVBr). METHODS: This retrospective longitudinal study included 43 eyes of 43 patients (74.5 ± 9.8 years old, male to female ratio 31:12) with nAMD treated with IVBr (29 eyes) or IVRbs (14 eyes). OBF in the optic nerve head (ONH) and choroid (Ch) was measured with laser speckle flowgraphy (Softcare Co., Ltd., Fukutsu, Japan) before and one month after treatment. Changes in mean blur rate (MBR) before and after each treatment were tested using Wilcoxon's signed-rank tests and mixed-effect models for repeated measures. RESULTS: In the IVBr group, MBR was significantly reduced in both the ONH and Ch (p < 0.01). In contrast, the IVRbs group showed no significant change in MBR in either the ONH or Ch (p = 0.56, p = 1). The linear mixed effect model showed a significant interaction between time and anti-VEGF drugs for MBR in both the ONH and Ch (ONH: p = 0.04; Ch: p = 0.002). A post hoc pairwise comparison of estimated marginal means showed that MBR decreased significantly only after IVBr (p < 0.001). CONCLUSION: Our findings suggest that the short-term impact on OBF varies depending on the drug used for nAMD.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Biosimilares Farmacéuticos , Degeneración Macular , Disco Óptico , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Ranibizumab , Inyecciones Intravítreas , Estudios Longitudinales , Estudios Retrospectivos , Degeneración Macular/diagnóstico , Degeneración Macular/tratamiento farmacológico
15.
Int Ophthalmol ; 44(1): 182, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625418

RESUMEN

BACKGROUND/AIMS: This work aimed to investigate changes in optic nerve head (ONH) morphometry based on Bruch membrane opening in children with extensive nocturnal intraocular pressure (IOP) elevations. METHODS: The course of Bruch membrane opening-based optic nerve head (ONH) morphometry was analysed in thirty-two patients younger than 18 years with evaluable SD-OCT examinations of the ONH and nocturnal posture-dependent IOP elevation above 25 mmHg. Longitudinal changes in neuroretinal rim tissue, as measured by Bruch Membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness, were assessed. RESULTS: One year after the 24 h IOP measurement, global BMO-MRW (- 1.61 ± 16.8 µm, n.s.; p = 0.611) and RNFL (+ 0.64 ± 3.17 µm; n.s.; p = 0.292) measurements were not significantly different from the baseline. No significant BMO-MRW reduction (- 3.91 ± 24.3 µm; n.s. p = 0.458) or deviation in RNFL thickness (+ 1.10 ± 3.52 µm) was observed at the four-year follow-up. Absolute IOP values measured in the supine position did not correlate with changes in global BMO-MRW or RNFL thickness. CONCLUSION: Posture-dependent IOP elevations do not seem to influence retinal nerve fibre layer thickness or Bruch membrane opening-based morphometric data in childhood.


Asunto(s)
Oftalmopatías , Disco Óptico , Niño , Humanos , Presión Intraocular , Tonometría Ocular , Retina , Postura
16.
Transl Vis Sci Technol ; 13(4): 10, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38578635

RESUMEN

Purpose: This study aims to determine whether OCT-derived rates of change in minimum rim width (MRW) are associated with and can potentially predict corresponding alterations in retinal nerve fiber layer thickness (RNFLT) in people with glaucoma. Methods: The rates of change between six-monthly visits were taken from 568 eyes of 278 participants in the P3 Study. Structural equation models (SEM) assessed whether one parameter was predicted by the concurrent or previous rate of the other parameter, after adjusting for its own rate in the previous time interval. Root mean square error of approximation (RMSEA, with 90% confidence intervals [CI]), Tucker Lewis index (TLI) and the comparative fit index (CFI) assessed goodness of fit. Results: Models without a time lag provided a better fit for the data (RMSEA = 0.101 [CI, 0.089, 0.113]), compared to a model featuring a time lag in RNFLT (RMSEA = 0.114 [CI, 0.102, 0.126]) or MRW (RMSEA = 0.114 [CI, 0.102, 0.127]). The SEMs indicated that rates for both MRW and RNFLT were predicted by their own rate in the previous time interval and by the other measure's change in the concurrent time interval (P > 0.001 for all). No evidence of a clinically significant time lag for either parameter was determined. Conclusions: MRW and RNFLT exhibit concurrent changes over time in patients with glaucoma, with no clinically significant time lag determined. Translational Relevance: RNFLT may be more useful than MRW in early glaucoma assessment because of its previously reported lower variability and reduced sensitivity to intraocular pressure changes.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Células Ganglionares de la Retina , Fibras Nerviosas , Retina , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica
17.
J Biomech ; 168: 112113, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38648717

RESUMEN

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.


Asunto(s)
Microscopía de Fuerza Atómica , Animales , Microscopía de Fuerza Atómica/métodos , Ratones , Ratas , Esclerótica/fisiología , Esclerótica/diagnóstico por imagen , Córnea/fisiología , Córnea/diagnóstico por imagen , Malla Trabecular/fisiología , Malla Trabecular/diagnóstico por imagen , Crioultramicrotomía/métodos , Disco Óptico/diagnóstico por imagen , Disco Óptico/fisiología , Fenómenos Biomecánicos
18.
Exp Eye Res ; 243: 109882, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38582182

RESUMEN

Retinal oximetry could provide insights into the pathophysiology of optic nerve disease, including optic disc drusen (ODD). Vessel selection for oximetry analysis is based on morphological characteristics of arterioles and venules and supported by an overlay of estimated blood oxygen saturations. The purpose of this cross-sectional study was to determine the validity of this vessel selection procedure by comparing it with vessel selection supported by video fluorescein angiography (FA). The study included 36 eyes of 36 patients with ODD who underwent retinal oximetry (Oxymap retinal oximeter T1) followed by FA (Heidelberg Spectralis). Two trained graders selected vessel segments in a pre-defined measurement area around the optic disc. One of these graders additionally performed the vessel segment selection with the support of FA images. When performed by the same grader, FA-supported and non-FA-supported vessel selection did not lead to significant differences in total vessel segment length, estimated oxygen saturations or vessel diameters (all p > 0.05). Inter-grader differences were found for arterial and venous segment lengths and arterial saturation (p < 0.05). A similar tendency was found for the arteriovenous saturation difference (p = 0.10). In conclusion, identifying vessel segments for retinal oximetry analysis based on vessel morphology and supported by a color-coded saturation overlay appears to be a valid method without the need for invasive angiography. A numerically small inter-grader variation may influence oximetry results. Further studies of retinal oximetry in ODD are warranted.


Asunto(s)
Angiografía con Fluoresceína , Drusas del Disco Óptico , Oximetría , Vasos Retinianos , Humanos , Oximetría/métodos , Femenino , Masculino , Angiografía con Fluoresceína/métodos , Estudios Transversales , Persona de Mediana Edad , Vasos Retinianos/patología , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/fisiopatología , Drusas del Disco Óptico/fisiopatología , Drusas del Disco Óptico/diagnóstico , Adulto , Oxígeno/sangre , Reproducibilidad de los Resultados , Anciano , Saturación de Oxígeno/fisiología , Disco Óptico/irrigación sanguínea
19.
Sci Rep ; 14(1): 8889, 2024 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632299

RESUMEN

We aimed to investigate the changes in cupping in chiasmal lesion optic neuropathy (chON) compared to baseline optic disc and glaucoma. We used a novel study design to enroll patients who had fundus photographs incidentally taken during routine health check-ups prior to the onset of optic neuropathy. In 31 eyes (21 patients) with chON and 33 eyes (30 patients) with glaucoma, we investigated the change in cup-to-disc (C/D) area from the baseline to overt cupping using flicker analysis. Compared to the baseline, 23 eyes (74.2%) had increased cup size and 3 (9.7%) had vascular configuration changes in the chONgroup; in contrast, all glaucoma eyes exhibited changes in cup size and vascular configuration. The increase in C/D area ratio was significantly smaller in chON (0.04 ± 0.04) compared to glaucoma (0.10 ± 0.04, P < 0.001); the minimum residual neuroretinal rim width showed a more pronounced difference (29.7 ± 8.2% vs 7.1 ± 3.9%, P < 0.001). The changes distributed predominantly towards the nasal direction in chON, contrasting the changes to the arcuate fibers in glaucoma. In conclusion, our results provide the first longitudinal evidence of true pathological cupping in chONcompared to photographically disease-free baseline. The marked difference in the residual minimum rim width reaffirms the importance of rim obliteration in the differential diagnosis between the two diseases.


Asunto(s)
Glaucoma , Disco Óptico , Enfermedades del Nervio Óptico , Humanos , Disco Óptico/patología , Glaucoma/patología , Enfermedades del Nervio Óptico/patología , Quiasma Óptico/patología , Fondo de Ojo , Presión Intraocular
20.
Klin Monbl Augenheilkd ; 241(4): 562-570, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38653313

RESUMEN

PURPOSE: Proof of concept of ex vivo retinal vessel diameter measurements in human postmortem eyes. METHODS: En face near-infrared (IR) images and optical coherence tomography (OCT) of the optic nerve head (ONH) were captured ex vivo with a Heidelberg Engineering Spectralis (Spectralis, version 7.0.4, Image Capture Module, version 1.2.4, Heidelberg Heidelberg, Germany) device, using a custom-made eye chamber holding and positioning the eyes during the image process. Thirty-two formaldehyde-fixated eyes of 16 patients were imaged. In the IR images, two independent graders measured retinal vessel diameters at the intersection of a drawn circle centered on the ONH with diameters of 2.0 mm and 3.4 mm, respectively. The anatomically corresponding measurements between both graders were statistically analyzed using a Wilcoxon signed-rank test. RESULTS: A total of 246 matched measurements of both graders were analyzed across all 32 imaged eyes. Statistically significant differences between the graders were found for arterioles at 2 mm from the ONH. The other measurements did not show statistically significant intergrader differences. The mean values for arteriole diameters were 72.2 µm at 2.0 mm and 61.5 µm at 3.4 mm for grader 1, and 66.4 µm at 2.0 mm and 63.2 µm at 3.4 mm for grader 2. The mean diameter for venules were 75.5 µm at 2.0 mm and 79.3 µm at 3.4 mm for grader 1, and 67.4 µm at 2 mm and 79.1 µm at 3.4 mm for grader 2. CONCLUSION: To the best of our knowledge, this is the first study to present IR image-based retinal vessel diameters in ex vivo postmortem eyes. Retinal IR/OCT imaging is possible, and measurements are reproducible in formaldehyde-fixated human eyes. Fixation artefacts result in lower image quality, and this can impose challenges in correctly detecting, classifying, and measuring retinal vessels.


Asunto(s)
Disco Óptico , Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Femenino , Masculino , Disco Óptico/diagnóstico por imagen , Disco Óptico/irrigación sanguínea , Disco Óptico/patología , Anciano , Reproducibilidad de los Resultados , Persona de Mediana Edad , Sensibilidad y Especificidad , Anciano de 80 o más Años , Autopsia/métodos , Cadáver
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA