Zhonghua Yi Xue Za Zhi ; 104(27): 2502-2512, 2024 Jul 16.
Artículo en Chino | MEDLINE | ID: mdl-38978374

RESUMEN

Cervical artificial disc replacement preserves the range of motion after the decompression, and this technology has achieved good clinical results. The indications, surgical procedures, and perioperative management of cervical disc arthroplasty are different from traditional anterior cervical decompression and fusion. The Health Management and Enhanced Recovery of Cervical Spine Disorders Committee, Chinese Research Hospital Association has established an expert group to draw up this expert consensus through literature analysis and professional discussions. The purpose of this consensus is to standardize the surgical indications and patient selection of cervical artificial disc replacement, to guide surgical procedures and perioperative management, and to improve the clinical outcomes of cervical artificial disc replacement.


Asunto(s)
Vértebras Cervicales , Reeemplazo Total de Disco , Humanos , Reeemplazo Total de Disco/métodos , Vértebras Cervicales/cirugía , Fusión Vertebral/métodos , Disco Intervertebral/cirugía , Descompresión Quirúrgica/métodos , Consenso , Rango del Movimiento Articular
2.
Med Sci Monit ; 30: e944645, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39014873

RESUMEN

BACKGROUND Lower back pain is a common problem in the general population. Medical treatment is the first choice for patients without severe pain and major motor weakness. If patients do not benefit from conservative treatment, minimally invasive treatment is recommended. Ozone nucleolysis has recently been used to reduce pain and inflammation in herniated discs and other spinal conditions. This retrospective study from a single center aimed to evaluate the effects of ozone disc nucleolysis in the management of 149 patients with herniated lumbar intervertebral discs from 2022 to 2024. MATERIAL AND METHODS Between 2022 and 2024, intradiscal ozone nucleolysis was performed under operating room C-arm scopy in 149 patients who received medical treatment and physical therapy without surgical indication but did not benefit, and the results were evaluated retrospectively. Visual Analog Scale (VAS) scores and Oswestry Disability Index (ODI) scores were recorded before the procedure, and at 1 month, 3 months, 6 months, and 1 year. RESULTS The study enrolled 149 patients, comprising 61 males and 88 females, with an overall mean age of 43.9±4.7 years. The procedure was performed as 1 level in 138 patients and 2 levels in 11 patients. Among patients who underwent procedures based on lumbar MRI findings, 15 involved the L3-L4 intervertebral disc, 3 involved both the L3-L4 and L4-L5 discs, 90 involved the L4-L5 disc, and 31 involved the L5-S1 disc. Post-procedure VAS scores were significantly different at 1 month and 6 months (P<0.05). Post-procedure ODI scores were also significantly different at 1 month and 6 months. CONCLUSIONS Due to its low complication rate and effectiveness in treating lumbar disc herniation, ozone chemonucleolysis should be considered for use in patients who do not have a surgical indication or do not accept surgical intervention and did not benefit from medical treatment and physical therapy.


Asunto(s)
Desplazamiento del Disco Intervertebral , Vértebras Lumbares , Ozono , Humanos , Masculino , Femenino , Ozono/uso terapéutico , Ozono/farmacología , Adulto , Estudios Retrospectivos , Vértebras Lumbares/cirugía , Persona de Mediana Edad , Dolor de la Región Lumbar/tratamiento farmacológico , Imagen por Resonancia Magnética/métodos , Resultado del Tratamiento , Dimensión del Dolor , Disco Intervertebral/cirugía
3.
J Clin Neurosci ; 126: 319-327, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39018828

RESUMEN

BACKGROUND: Artificial lumbar disc replacement is an effective method for the treatment of lumbosacral degenerative diseases. An appropriate artificial intervertebral disc device is of great significance for the maintenance of spinal stability and activity. METHODS: Two finite element models of ProDisc-L prosthesis replacement and improved prosthesis replacement were constructed by using the finite element model of complete lumbar L1-L5 segment established by CT image data. The mechanical properties of the surgical models before and after improvement were analyzed and evaluated. RESULTS: The ProDisc-L group and the improved group showed similar lumbar's ROM and maintained a similar ROM with the normal lumbar spine. There was no significant change in the intervertebral disc's pressure between the adjacent segments of the two prosthesis groups compared with the normal group, but the stress value of the improved prosthesis group was slightly lower than that of the ProDisc-L group. In addition, the improved prosthesis replacement has more reasonable stress distribution. CONCLUSIONS: Compared with the ProDisc-L prosthesis, the improved prosthesis can reduce the pressure in the intervertebral disc of the adjacent segment, the contact stress of the facet joint and the artificial prosthesis, which provides reference for the subsequent design of the prosthesis structure.


Asunto(s)
Análisis de Elementos Finitos , Vértebras Lumbares , Reeemplazo Total de Disco , Humanos , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Reeemplazo Total de Disco/métodos , Reeemplazo Total de Disco/instrumentación , Disco Intervertebral/cirugía , Disco Intervertebral/diagnóstico por imagen , Fenómenos Biomecánicos/fisiología , Rango del Movimiento Articular/fisiología , Diseño de Prótesis , Prótesis e Implantes , Masculino , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen
4.
Int J Artif Organs ; 47(6): 411-417, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38904355

RESUMEN

Artificial disc replacement (ADR) is a clinical procedure used to diagnose cervical degenerative disc disease, preserving range of motion (ROM) at the fixation level and preventing adjacent segment degeneration (ASD). This study analyzed the biomechanics of ADR by examining range of motion (ROM), stress levels in bone and implants, and strain in the bone-implant interface using multi-scale loadings. The study focused on single- and double-level patients across various loading scales during physiological motions within the cervical spine. Results showed increased ROM in single-level and double-level fixations during physiological loadings, while ROM decreased at the adjacent level of fixation with the intact cervical spine model. The Prodisc-Implant metal endplate experienced a maximum von Mises stress of 432 MPa during axial rotation, confirming the long durability and biomechanical performance of the bone-implant interface.


Asunto(s)
Vértebras Cervicales , Análisis de Elementos Finitos , Rango del Movimiento Articular , Reeemplazo Total de Disco , Humanos , Vértebras Cervicales/cirugía , Vértebras Cervicales/fisiopatología , Fenómenos Biomecánicos , Reeemplazo Total de Disco/métodos , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/fisiopatología , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Estrés Mecánico , Diseño de Prótesis , Masculino , Soporte de Peso , Adulto
5.
Cells ; 13(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38891119

RESUMEN

Although discectomy is commonly performed for lumbar intervertebral disc (IVD) herniation, the capacity for tissue repair after surgery is limited, resulting in residual lower back pain, recurrence of IVD herniation, and progression of IVD degeneration. Cell-based therapies, as one-step procedures, are desirable for enhancing IVD repair. This study aimed to investigate the therapeutic efficacy of a combination of newly developed ultra-purified alginate (UPAL) gel and bone marrow aspirate concentrate (BMAC) implantation for IVD repair after discectomy. Prior to an in vivo study, the cell concentration abilities of three commercially available preparation kits for creating the BMAC were compared by measuring the number of bone marrow mesenchymal stem cells harvested from the bone marrow of rabbits. Subsequently, canine-derived BMAC was tested in a canine model using a kit which had the highest concentration rate. At 24 weeks after implantation, we evaluated the changes in the magnetic resonance imaging (MRI) signals as well as histological degeneration grade and immunohistochemical analysis results for type II and type I collagen-positive cells in the treated IVDs. In all quantitative evaluations, such as MRI and histological and immunohistochemical analyses of IVD degeneration, BMAC-UPAL implantation significantly suppressed the progression of IVD degeneration compared to discectomy and UPAL alone. This preclinical proof-of-concept study demonstrated the potential efficacy of BMAC-UPAL gel as a therapeutic strategy for implementation after discectomy, which was superior to UPAL and discectomy alone in terms of tissue repair and regenerative potential.


Asunto(s)
Alginatos , Modelos Animales de Enfermedad , Degeneración del Disco Intervertebral , Disco Intervertebral , Animales , Perros , Alginatos/química , Alginatos/farmacología , Disco Intervertebral/cirugía , Disco Intervertebral/patología , Disco Intervertebral/efectos de los fármacos , Conejos , Degeneración del Disco Intervertebral/patología , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/terapia , Prueba de Estudio Conceptual , Geles , Células de la Médula Ósea/citología , Células Madre Mesenquimatosas/citología , Imagen por Resonancia Magnética , Masculino , Trasplante de Médula Ósea/métodos
6.
Sci Rep ; 14(1): 13181, 2024 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-38849364

RESUMEN

The biomechanical aspects of adjacent segment degeneration after Adult Idiopathic Scoliosis (AdIS) corrective surgery involving postoperative changes in motion and stress of adjacent segments have yet to be investigated. The objective of this study was to evaluate the biomechanical effects of corrective surgery on adjacent segments in adult idiopathic scoliosis by finite element analysis. Based on computed tomography data of the consecutive spine from T1-S1 of a 28-year-old male patient with adult idiopathic scoliosis, a three-dimensional finite element model was established to simulate the biomechanics. Two posterior long-segment fixation and fusion operations were designed: Strategy A, pedicle screws implanted in all segments of both sides, and Strategy B, alternate screws instrumentation on both sides. The range of motion (ROM), Maximum von Mises stress value of intervertebral disc (IVD), and Maximum von Mises stress of the facet joint (FJ) at the fixation adjacent segment were calculated and compared with data of the preoperative AdIS model. Corrective surgery decreased the IVD on the adjacent segments, increased the FJ on the adjacent segments, and decreased the ROM of the adjacent segments. A greater decrease of Maximum von Mises stress was observed on the distal adjacent segment compared with the proximal adjacent segment. The decrease of Maximum von Mises stress and increment of Maximum von Mises stress on adjacent FJ in strategy B was greater than that in strategy A. Under the six operation modes, the change of the Maximum von Mises stress on the adjacent IVD and FJ was significant. The decrease in ROM in the proximal adjacent segment was greater than that of the distal adjacent segment, and the decrease of ROM in strategy A was greater than that in strategy B. This study clarified the biomechanical characteristics of adjacent segments after AdIS corrective surgery, and further biomechanical analysis of two different posterior pedicle screw placement schemes by finite element method. Our study provides a theoretical basis for the pathogenesis, prevention, and treatment of adjacent segment degeneration after corrective surgery for AdIS.


Asunto(s)
Análisis de Elementos Finitos , Rango del Movimiento Articular , Escoliosis , Fusión Vertebral , Humanos , Escoliosis/cirugía , Escoliosis/fisiopatología , Adulto , Masculino , Fenómenos Biomecánicos , Fusión Vertebral/métodos , Tornillos Pediculares , Tomografía Computarizada por Rayos X , Estrés Mecánico , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Disco Intervertebral/diagnóstico por imagen , Vértebras Torácicas/cirugía , Vértebras Torácicas/fisiopatología
7.
Turk Neurosurg ; 34(4): 640-646, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38874242

RESUMEN

AIM: To explore the relationship between the retroperitoneal vasculature and anterior surface of the lower spine, and to establish values for aiding in prediction of the pertinence of anterior approach at the L4-L5 and L5-S1 intervertebral discs. MATERIAL AND METHODS: The study included 13 fresh human cadavers. After exploration of the abdominal cavity and removal of the visceral organs, the vasculature, and anterior spinal surface were revealed beneath the lower extension of the perirenal fascia. Morphometric measurements of the great vessels and the intervertebral discs were obtained. All measurements were analyzed and presented as mean and standard deviation. Differences in the values between sexes were assessed. RESULTS: The anterior height of the L4-L5 and L5-S1 intervertebral disc was 6.8 ± 0.81 mm and 6.7 ± 0.99 mm, respectively. The widths of the aorta, inferior vena cava, right and left common iliac arteries, and right, and left common iliac veins were 16.4 ± 3.58, 20.6 ± 3.36, 11.5 ± 2.32, 11.5 ± 2.43, 14.7 ± 3.13, and 15.5 ± 3.27 mm, respectively. The mean aortic bifurcation angle was 45.5°. The aortic bifurcation was located above the lower endplate of the L4 vertebrae in 53.8% of the cadavers. The area of the interarterial and interiliac trigones was 14.6 ± 5.33 cm < sup > 2 < /sup > and 7.1 ± 4.35 cm2, respectively. No statistically significant differences were noted between the sexes. CONCLUSION: An elaborate radiological examination of the vasculature should be performed prior to surgery to avoid unwanted vascular complications during the anterior approach. Knowing the area of the interarterial and interiliac triangles and the aortic bifurcation location could be aid in assessing the safe working zone.


Asunto(s)
Cadáver , Disco Intervertebral , Vértebras Lumbares , Humanos , Vértebras Lumbares/anatomía & histología , Vértebras Lumbares/cirugía , Masculino , Femenino , Disco Intervertebral/anatomía & histología , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/cirugía , Persona de Mediana Edad , Anciano , Vena Ilíaca/anatomía & histología , Arteria Ilíaca/anatomía & histología , Arteria Ilíaca/diagnóstico por imagen , Vena Cava Inferior/anatomía & histología , Vena Cava Inferior/cirugía , Espacio Retroperitoneal/anatomía & histología , Adulto
8.
Spine (Phila Pa 1976) ; 49(16): E262-E271, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38800946

RESUMEN

STUDY DESIGN: We constructed finite element (FE) models of the cervical spine consisting of C2-C7 and predicted the biomechanical effects of different surgical procedures and instruments on adjacent segments, internal fixation systems, and the overall cervical spine through FE analysis. OBJECTIVE: To compare the biomechanical effects between the zero-profile device and cage-plate device in skip-level multistage anterior cervical discectomy and fusion (ACDF). SUMMARY OF BACKGROUND DATA: ACDF is often considered the standard treatment for degenerative cervical spondylosis. However, the selection of surgical methods and instruments in cases of skip-level cervical degenerative disk disease is still controversial. MATERIALS AND METHODS: Three FE models were constructed, which used noncontiguous 2-level Zero-P (NCZP) devices for C3/4 and C5/6, a noncontiguous 2-level cage-plate (NCCP) for C3/4 and C5/6, and a contiguous 3-level cage-plate (CCP) for C3/6. Simulate daily activities in ABAQUS. The range of motion (ROM), von Mises stress distribution of the endplate and internal fixation system, and intervertebral disk pressure (IDP) of each model were recorded and compared. RESULTS: Similar to the stress of the cortical bone, the maximum stress of the Zero-P device was higher than that of the CP device for most activities. The ROM increments of the superior, inferior, and intermediate segments of the NCZP model were lower than those of the NCCP and CCP models in many actions. In terms of the IDP, the increment value of stress for the NCZP model was the smallest, whereas those of the NCCP and CCP models were larger. Similarly, the increment value of stress on the endplate also shows the minimum in the NCZP model. CONCLUSIONS: Noncontiguous ACDF with zero profile can reduce the stress on adjacent intervertebral disks and endplates, resulting in a reduced risk of adjacent segment disease development. However, the high cortical bone stress caused by the Zero-P device may influence the risk of fractures.


Asunto(s)
Vértebras Cervicales , Discectomía , Análisis de Elementos Finitos , Degeneración del Disco Intervertebral , Rango del Movimiento Articular , Fusión Vertebral , Vértebras Cervicales/cirugía , Humanos , Fenómenos Biomecánicos/fisiología , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/fisiopatología , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Discectomía/métodos , Discectomía/instrumentación , Estrés Mecánico , Fijadores Internos , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Placas Óseas
9.
BMC Musculoskelet Disord ; 25(1): 369, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730401

RESUMEN

BACKGROUND: One goal of Anterior Cervical Discectomy and Fusion (ACDF) is to restore the loss of intervertebral disc height (IDH) results from the degenerative process. However, the effects of IDH on postoperative dysphagia after ACDF remain unclear. METHODS: Based on the results of a one-year telephone follow-up, A total of 217 consecutive patients after single-level ACDF were enrolled. They were divided into dysphagia and non-dysphagia groups. The age, BMI, operation time and blood loss of all patients were collected from the medical record system and compared between patients with and without dysphagia. Radiologically, IDH, spinous process distance (SP) of the operated segment, and C2-7 angle (C2-7 A) were measured preoperatively and postoperatively. The relationship between changes in these radiological parameters and the development of dysphagia was analyzed. RESULTS: Sixty-three (29%) cases exhibited postoperative dysphagia. The mean changes in IDH, SP, and C2-7 A were 2.84 mm, -1.54 mm, and 4.82 degrees, respectively. Changes in IDH (P = 0.001) and changes in C2-7 A (P = 0.000) showed significant differences between dysphagia and non-dysphagia patients. Increased IDH and increased C2-7 A (P = 0.037 and 0.003, respectively) significantly and independently influenced the incidence of postoperative dysphagia. When the change in IDH was ≥ 3 mm, the chance of developing postoperative dysphagia for this patient was significantly greater. No significant relationship was observed between the change in spinous process distance (SP) and the incidence of dysphagia. The age, BMI, operation time and blood loss did not significantly influence the incidence of postoperative dysphagia. CONCLUSION: The change in IDH could be regarded as a predictive factor for postoperative dysphagia after single-level ACDF.


Asunto(s)
Vértebras Cervicales , Trastornos de Deglución , Discectomía , Disco Intervertebral , Complicaciones Posoperatorias , Fusión Vertebral , Humanos , Trastornos de Deglución/etiología , Trastornos de Deglución/epidemiología , Femenino , Masculino , Persona de Mediana Edad , Discectomía/efectos adversos , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Fusión Vertebral/efectos adversos , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Disco Intervertebral/cirugía , Disco Intervertebral/diagnóstico por imagen , Estudios de Seguimiento
10.
Clin Neurol Neurosurg ; 242: 108349, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38820945

RESUMEN

OBJECTIVES: Alkaptonuria is a rare inborn disorder of phenylalanine and tyrosine metabolism. It is characterized by an accumulation of homogentisic acid and its oxidation products, possibly resulting into connective tissue damaging. "Ochronosis" is a main feature, which is characterized by tissue discoloration and even alkaptonuric arthropathy. Cervical spine involvement is exceptional and there is a paucity of reports on surgical interventions in these patients. We explored the literature concerning cervical spine involvement in patients with alkaptonuria. PATIENTS AND METHODS: We performed a review of the literature, in which patients with alkaptonuric degenerative changes of the cervical spine were examined. Articles were obtained from MEDLINE. Search terms included: "cervical", "alkaptonuria", "alkaptonuric changes" and "black disc". Additional studies were identified by checking reference lists. Furthermore, we present the case of a 46 year old patient with critical cervical spinal canal stenosis who underwent C6-C7 anterior cervical microdiscectomy and interbody fusion, in order to prevent myelopathic changes. CARE statement guidelines were followed. RESULTS: Peroperatively, we did not encounter any macroscopic abnormalities of the skin, muscles or ligaments. A black discoloration of the nucleus pulposus was observed. Peroperative and postoperative course was uneventful. CONCLUSION: Alkaptonuric degenerative abnormalities most commonly involve the lumbar spine, although the cervical spine can be affected in rare cases. Most frequently, the diagnosis of alkaptonuria can be made based on the clinical phenotype many years before symptoms secondary to ochronotic arthropathy develop. A retrospective diagnosis based on peroperative black discoloration of spinal structures has been described. A black discoloration of the intervertebral disc should encourage the neurosurgeon to further explore the possibility of alkaptonuria, even in the absence of a clear phenotype. Surgical results are mostly satisfactory. Further studies are required in order to better understand this pathology and its postoperative course.


Asunto(s)
Alcaptonuria , Vértebras Cervicales , Disco Intervertebral , Ocronosis , Humanos , Persona de Mediana Edad , Alcaptonuria/complicaciones , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Discectomía/métodos , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/patología , Disco Intervertebral/cirugía , Ocronosis/complicaciones , Fusión Vertebral/métodos , Estenosis Espinal/cirugía , Estenosis Espinal/diagnóstico por imagen
11.
Clin Biomech (Bristol, Avon) ; 116: 106270, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38776646

RESUMEN

BACKGROUND: A novel interspinous fixation system based on anatomical parameters and incorporating transfacetopedicular screws, was developed to treat degenerative disc diseases. The biomechanical characteristics of the novel system were evaluated using finite element analysis in comparison to other classical interspinous spacers. METHODS: The L1-S1 lumbar spine finite element models were surgically implanted with the novel system, Coflex and DIAM devices at the L4/L5 segment to assess the range of motion, the pression distribution of intervertebral disc, the peak stresses on the spinous process and implant during various motions. FINDINGS: Range of motions of the L4/L5 surgical segment were reduced by 29.13%, 61.27%, 77.35%, 33.33%, and the peak stresses of intervertebral disc were decreased by 36.82%, 67.31%, 73.00%, 69.57% for the novel system in flexion, extension, lateral bending, and axial rotation when compared with the Coflex, and they were declined by 34.53%, 57.86%, 75.81%, 25.21%; 36.22%, 67.31%, 75.01%, 71.40% compared with DIAM. The maximum stresses of the spinous process were 29.93 MPa, 24.66 MPa, 14.45 MPa, 24.37 MPa in the novel system, and those of Coflex and DIAM were 165.3 MPa, 109 MPa, 84.79 MPa, 47.66 MPa and 52.59 MPa, 48.78 MPa, 50.27 MPa, 44.16 MPa during the same condition. INTERPRETATION: Compared to other interspinous spacer devices, the novel interspinous fixation system demonstrated excellent stability, effectively distributing load on the intervertebral disc, and reducing the risk of spinous process fractures. The personalized design of the novel interspinous fixation system could be a viable option for treating degenerative disc diseases.


Asunto(s)
Análisis de Elementos Finitos , Degeneración del Disco Intervertebral , Vértebras Lumbares , Rango del Movimiento Articular , Humanos , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/fisiopatología , Vértebras Lumbares/cirugía , Vértebras Lumbares/fisiopatología , Fenómenos Biomecánicos , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Estrés Mecánico , Tornillos Óseos , Simulación por Computador , Masculino , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos
12.
Clin Biomech (Bristol, Avon) ; 116: 106266, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38821035

RESUMEN

BACKGROUND: Most ball-in-socket artificial lumbar disc implanted in the spine result in increased hypermobility of the operative level and overloading of the facet joint. METHODS: A finite element model was established and validated for the lumbar spine (L1-L5). The structure of the Mobidisc prosthesis was modified, resulting in the development of two new intervertebral disc prostheses, Movcore and Mcopro. The prostheses were implanted into the L3/L4 level to simulate total disc replacement, and the biomechanical properties of the lumbar spine model were analyzed after the operation. FINDINGS: Following the implantation of the prostheses, the mobility of operative level, peak stress of lumbar spine models, and peak stress of facet joint increased. The performance of mobility was found to be more similar between Movcore and Mobidisc. The mobility and facet joint peak stress of the Mcopro model decreased progressively with an increase in the Young's modulus of the artificial annulus during flexion, extension, and lateral bending. Among all the models, the Mcopro50 model had the mobility closest to the intact model. It showed a 3% decrease in flexion, equal range of motion in extension, a 9% increase in left lateral bending, a 7% increase in right lateral bending, and a 3% decrease in axial rotation. INTERPRETATION: The feasibility of the new intervertebral disc prostheses, Movcore and Mcopro, has been established. The Mcopro prosthesis, which features an artificial annular structure, offers significant advantages in terms of reduced mobility of the operative level and peak stress of facet joint.


Asunto(s)
Análisis de Elementos Finitos , Disco Intervertebral , Vértebras Lumbares , Rango del Movimiento Articular , Humanos , Vértebras Lumbares/cirugía , Vértebras Lumbares/fisiopatología , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Fenómenos Biomecánicos , Diseño de Prótesis , Reeemplazo Total de Disco/métodos , Estrés Mecánico , Prótesis e Implantes , Simulación por Computador , Modelos Biológicos , Articulación Cigapofisaria/cirugía , Articulación Cigapofisaria/fisiopatología
13.
J Neurol Surg A Cent Eur Neurosurg ; 85(5): 439-443, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38599624

RESUMEN

BACKGROUND: Quality of life (QoL) may be affected due to various reasons such as low back or leg pains with accompanying neurologic problems. Lumbar disk surgery is one of the most common performed surgeries to relieve those symptoms. Various anesthetic techniques can be used safely to perform lumbar disk surgeries. Properties that make an anesthetic technique good are mainly the quick onset and returning of the effects. This large retrospective study with patients who have undergone lumbar disk surgery under spinal anesthesia aims to evaluate the perioperative and postoperative parameters of the spinal anesthesia and review the literature. METHODS: Cases operated under spinal anesthesia between January 2017 and December 2020 were investigated, and 617 patients who underwent simple lumbar disk surgery were included in the study. Demographic characteristics and American Society of Anesthesiologists (ASA) physical status of the patients were recorded. Visual analog scale (VAS) and QoLscores were obtained before and after the operation. RESULTS: There were 282 (45.7%) male and 335 (54.3%) female patients with a mean age of 39.48 ± 16.71 years (range: 18-58 years) at symptom onset. The mean operating time was 46.3 minutes (range: 22-68 minutes). Average blood loss was 85 mL (range: 55-125 mL). All the patients were mobilized 6 to 12 hours after surgery. In our patient group, there were both high- and normal-risk groups in terms of the ASA physical status. During the clinical follow-up, a statistically significant improvement was found for the VAS and QoL scores (p < 0.05). CONCLUSIONS: In this large retrospective study, our results have confirmed that spinal anesthesia is at least comparable to general anesthesia and even superior to it in some aspects.


Asunto(s)
Anestesia Raquidea , Vértebras Lumbares , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Vértebras Lumbares/cirugía , Anestesia Raquidea/métodos , Estudios Retrospectivos , Adulto Joven , Adolescente , Resultado del Tratamiento , Calidad de Vida , Discectomía/métodos , Disco Intervertebral/cirugía , Desplazamiento del Disco Intervertebral/cirugía
14.
Comput Methods Programs Biomed ; 250: 108172, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38669718

RESUMEN

BACKGROUND AND OBJECTIVE: Degenerative diseases of the spine have a negative impact on the quality of life of patients. This study presents the results of numerical modelling of the mechanical behaviour of the lumbar spine with patient-specific conditions at physiological loads. This paper aims to numerically study the influence of degenerative changes in the spine and the presence of an endoprosthesis on the creation of conditions for tissue regeneration. METHODS: A numerical model of the mechanical behaviour of lumbar spine at healthy and after total disc replacement under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behaviour of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid. The nutritional pathways of the intervertebral disc in cases of healthy and osteoporotic bone tissues were predicted based on the analysis of the simulation results according to the mechanobiological principles. RESULTS: Simulation of total disc replacement showed that osseointegration of the artificial disc plates occurs only in healthy bone tissue. With total disc replacement in a patient with osteoporosis, there is an area of increased risk of bone resorption in the near-contact area, approximately 1 mm wide, around the fixators. Dynamic loads may improve the osseointegration of the implant in pathological conditions of the bone tissue. CONCLUSIONS: The results obtained in the case of healthy spine and osteoporotic bone tissues correspond to the experimental data on biomechanics and possible methods of IVD regeneration from the position of mechanobiological principles. The results obtained with an artificial disc (with keel-type fixation) showed that the use of this type of endoprosthesis in healthy bone tissues allows to reproduce the function of the natural intervertebral disc and does not contribute to the development of neoplastic processes. In the case of an artificial disc with osteoporosis of bone tissues, there is a zone with increased risk of tissue resorption and development of neoplastic processes in the area near the contact of the implant attachment. This circumstance can be compensated by increasing the loading level.


Asunto(s)
Simulación por Computador , Disco Intervertebral , Vértebras Lumbares , Reeemplazo Total de Disco , Humanos , Vértebras Lumbares/cirugía , Disco Intervertebral/cirugía , Disco Intervertebral/fisiopatología , Regeneración , Fenómenos Biomecánicos , Osteoporosis/fisiopatología , Oseointegración
15.
Spine Deform ; 12(4): 953-959, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38578598

RESUMEN

PURPOSE: To evaluate proximal junctional biomechanics of a MLSS relative to traditional pedicle screw fixation at the proximal extent of T10-pelvis posterior instrumentation constructs (T10-p PSF). METHODS: A previously validated three-dimensional osseoligamentous spinopelvic finite element (FE) model was used to compare proximal junctional range-of-motion (ROM), vertebral body stresses, and discal biomechanics between two groups: (1) T10-p with a T10-11 MLSS ("T10-11 MLSS") and (2) T10-p with a traditional T10 pedicle screw ("Traditional T10-PS"). RESULTS: The T10-11 MLSS had a 5% decrease in T9 cortical bone stress compared to Traditional T10-PS. Conversely, the T10 and T11 bone stresses increased by 46% and 98%, respectively, with T10-11 MLSS compared to Traditional T10-PS. Annular stresses and intradiscal pressures (IDP) were similar at T9-T10 between constructs. At the T10-11 disc, T10-11 MLSS decreased annular stresses by 29% and IDP by 48% compared to Traditional T10-PS. Adjacent ROM (T8-9 & T9-10) were similar between T10-11 MLSS and Traditional T10-PS. T10-11 MLSS had 39% greater ROM at T10-11 and 23% less ROM at T11-12 compared to Traditional T10-PS. CONCLUSIONS: In this FE analysis, a T10-11 MLSS at the proximal extent of T10-pelvis posterior instrumentation resulted in increased T10 and T11 cortical bone stresses, decreased discal annular stress and IDP and increased ROM at T10-11, and no change in ROM at the adjacent level. Given the complex and multifactorial nature of proximal junctional kyphosis, these results require additional biomechanical and clinical evaluations to determine the clinical utility of MLSS on the proximal junctions of thoracolumbar posterior instrumented fusions.


Asunto(s)
Análisis de Elementos Finitos , Vértebras Lumbares , Tornillos Pediculares , Rango del Movimiento Articular , Fusión Vertebral , Vértebras Torácicas , Humanos , Fenómenos Biomecánicos , Vértebras Torácicas/cirugía , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Estrés Mecánico , Disco Intervertebral/cirugía , Tornillos Óseos
16.
J Neurosurg Spine ; 41(1): 1-8, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579351

RESUMEN

OBJECTIVE: Facet joint violation (FJV) is associated with postoperative low-back pain and is a confirmed risk factor for adjacent-segment degeneration, a long-term complication of lumbar fusion surgery. The authors' knowledge of its mechanisms comes from in vitro biomechanical research only; there is a lack of radiographic evidence of the effects of violation on the superior adjacent-segment facet joint, intervertebral disc, and other local radiographic parameters. Furthermore, any differences between unilateral and bilateral violation remain relatively unclear. The authors therefore aimed to explore the effects of nonviolation and unilateral and bilateral violation on radiographic degeneration of the facet joint and intervertebral disc at the fusion and superior adjacent segment. Patient-reported clinical outcomes were compared at the 2-year follow-up. METHODS: The authors retrospectively analyzed data from 148 patients with lumbar degenerative diseases who underwent single-segment minimally invasive transforaminal lumbar interbody fusion between 2016 and 2020. FJV and facet joint degeneration were evaluated and graded using Shah's method and Pathria's standard, respectively. Radiographic parameters, including disc height and intervertebral Cobb angle at the fusion and superior adjacent segment, were measured. Clinical outcomes were evaluated using visual analog scale (VAS) and Japanese Orthopaedic Association scores. RESULTS: Preoperative data were comparable among the 3 groups (nonviolation, unilateral violation, and bilateral violation) (p > 0.05). Patient-reported clinical outcomes were followed up for at least 2 years (average duration 28.17 ± 6.17 months). At the last follow-up, facet joint degeneration grades were sequentially increased in the nonviolation, unilateral violation, and bilateral violation groups (p = 0.006). The unilateral (2.45 ± 2.17 mm) and bilateral (2.70 ± 1.94 mm) violation groups had more severe losses of disc height in the superior adjacent segment than did the nonviolation group (1.31 ± 2.01 mm). The VAS low-back pain and Japanese Orthopaedic Association scores in the bilateral (2.57 ± 1.44 and 19.83 ± 2.84, respectively) and unilateral (2.26 ± 0.79 and 20.43 ± 3.85, respectively) violation groups were significantly worse than in the nonviolation group (1.69 ± 1.12 and 21.80 ± 3.36, respectively) (p < 0.05). By contrast, there were no significant between-group differences in disc height, intervertebral Cobb angle in the fusion segment, or VAS leg pain scores (p > 0.05). CONCLUSIONS: FJV was associated with postoperative low-back pain and worse functional outcomes. It also aggravated facet joint and intervertebral disc changes in the superior adjacent segment, especially when bilateral violation occurred; this may be part of the mechanisms of adjacent-segment degeneration.


Asunto(s)
Degeneración del Disco Intervertebral , Vértebras Lumbares , Fusión Vertebral , Articulación Cigapofisaria , Humanos , Masculino , Femenino , Fusión Vertebral/métodos , Persona de Mediana Edad , Articulación Cigapofisaria/diagnóstico por imagen , Articulación Cigapofisaria/cirugía , Estudios Retrospectivos , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Anciano , Resultado del Tratamiento , Dolor de la Región Lumbar/cirugía , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/etiología , Adulto , Complicaciones Posoperatorias/diagnóstico por imagen , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/cirugía
17.
J Orthop Surg Res ; 19(1): 227, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38581052

RESUMEN

OBJECTIVE: Anterior cervical discectomy and fusion (ACDF) is the standard procedure for the treatment of cervical spinal stenosis (CSS), but complications such as adjacent segment degeneration can seriously affect the long-term efficacy. Currently, posterior endoscopic surgery has been increasingly used in the clinical treatment of CSS. The aim of this study was to compare the clinical outcomes of single-segment CSS patients who underwent full endoscopic laminotomy decompression or ACDF. METHODS: 138 CSS patients who met the inclusion criteria from June 2018 to August 2020 were retrospectively analyzed and divided into endoscopic and ACDF groups. The propensity score matching (PSM) method was used to adjust the imbalanced confounding variables between the groups. Then, perioperative data were recorded and clinical outcomes were compared, including functional scores and imaging data. Functional scores included Visual Analog Scale of Arms (A-VAS) and Neck pain (N-VAS), Japanese Orthopedic Association score (JOA), Neck Disability Index (NDI), and imaging data included Disc Height Index (DHI), Cervical range of motion (ROM), and Ratio of grey scale (RVG). RESULTS: After PSM, 84 patients were included in the study and followed for 24-30 months. The endoscopic group was significantly superior to the ACDF group in terms of operative time, intraoperative blood loss, incision length, and hospital stay (P < 0.001). Postoperative N-VAS, A-VAS, JOA, and NDI were significantly improved in both groups compared with the preoperative period (P < 0.001), and the endoscopic group showed better improvement at 7 days postoperatively (P < 0.05). The ROM changes of adjacent segments were significantly larger in the ACDF group at 12 months postoperatively and at the last follow-up (P < 0.05). The RVG of adjacent segments showed a decreasing trend, and the decrease was more marked in the ACDF group at last follow-up (P < 0.05). According to the modified MacNab criteria, the excellent and good rates in the endoscopic group and ACDF group were 90.48% and 88.10%, respectively, with no statistically significant difference (P > 0.05). CONCLUSION: Full endoscopic laminotomy decompression is demonstrated to be an efficacious alternative technique to traditional ACDF for the treatment of single-segment CSS, with the advantages of less trauma, faster recovery, and less impact on cervical spine kinematics and adjacent segmental degeneration.


Asunto(s)
Degeneración del Disco Intervertebral , Disco Intervertebral , Fusión Vertebral , Estenosis Espinal , Humanos , Estudios Retrospectivos , Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/cirugía , Laminectomía , Estenosis Espinal/diagnóstico por imagen , Estenosis Espinal/cirugía , Estenosis Espinal/complicaciones , Resultado del Tratamiento , Estudios de Seguimiento , Puntaje de Propensión , Fusión Vertebral/métodos , Discectomía/métodos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Descompresión
18.
BMC Musculoskelet Disord ; 25(1): 325, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659005

RESUMEN

OBJECTIVE: Investigating the early biomechanical effects of the one-hole split endoscope (OSE) technique on lumbar spine after decompression surgery. METHODS: A retrospective analysis was conducted on 66 patients with lumbar spinal stenosis (LSS) who underwent OSE technique surgery at the affiliated hospital of Binzhou Medical University from September 2021 to September 2022. The patients had complete postoperative follow-up records. The mean age was (51.73 ± 12.42) years, including 33 males and 33 females. The preoperative and postoperative imaging data were analyzed, including disc height (DH), foraminal height (FH), lumbar lordosis angle (LLA), changes in disc angle, anterior-posterior translation distance, and lumbar intervertebral disc Pfirrmann grading. The visual analogue scale (VAS) was applied to evaluate the severity of preoperative, postoperative day 1, postoperative 3 months, and final follow-up for back and leg pain. The Oswestry Disability Index (ODI) was applied to assess the functionality at all the listed time points. The modified MacNab criteria were applied to evaluate the clinical efficacy at the final follow-up. RESULTS: In 66 patients, there were statistically significant differences (p < 0.05) in DH and FH at the affected segments compared to preoperative values, whereas no significant differences (p > 0.05) were found in DH and FH at the adjacent upper segments compared to preoperative values. There was no statistically significant difference in the LLA compared to preoperative values (p > 0.05). Both the affected segments and adjacent upper segments showed statistically significant differences in Pfirrmann grading compared to preoperative values (p < 0.05). There were no statistically significant differences in the changes in disc angle or anterior-posterior translation distance in the affected or adjacent segments compared to preoperative values (p > 0.05). The VAS scores for back and leg pain, as well as the ODI, significantly improved at all postoperative time points compared to preoperative values. Among the comparisons at different time points, the differences were statistically significant (p < 0.05). The clinical efficacy was evaluated at the final follow-up using the modified MacNab criteria, with 51 cases rated as excellent, 8 cases as good, and 7 cases as fair, resulting in an excellent-good rate of 89.39%. CONCLUSIONS: The OSE technique, as a surgical option for decompression in the treatment of LSS, has no significant impact on lumbar spine stability in the early postoperative period. However, it does have some effects on the lumbar intervertebral discs, which may lead to a certain degree of degeneration.


Asunto(s)
Descompresión Quirúrgica , Disco Intervertebral , Vértebras Lumbares , Estenosis Espinal , Humanos , Femenino , Masculino , Estenosis Espinal/cirugía , Estenosis Espinal/diagnóstico por imagen , Persona de Mediana Edad , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Estudios Retrospectivos , Descompresión Quirúrgica/métodos , Descompresión Quirúrgica/instrumentación , Adulto , Disco Intervertebral/cirugía , Disco Intervertebral/diagnóstico por imagen , Resultado del Tratamiento , Anciano , Endoscopía/métodos , Dimensión del Dolor , Estudios de Seguimiento
19.
Clin Spine Surg ; 37(7): E283-E289, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38446591

RESUMEN

STUDY DESIGN: Cross-sectional study. OBJECTIVE: Assess trends of indications and contraindications for the use of Cervical Disk Arthroplasty (CDA). SUMMARY OF BACKGROUND DATA: As spine surgeons become more familiar with CDA, there have been expansions in indications. METHODS: The Medicare Provider Analysis and Review Limited Data Sets for 2009, 2014, and 2019 were utilized. Patients undergoing elective CDA were included. Diagnosis for index surgery and "contraindications" as defined by original CDA Investigative Device Exemption (IDE) criteria were assessed. Variables were identified by the International Classification of Diseases (ICD)-9 or ICD-10 diagnosis and procedural codes. RESULTS: A total of 1067 elective CDA patients were included. There were 230 patients in 2009, 300 patients in 2014, and 537 patients in 2019. The proportion of patients aged >65 increased from 35% to 51% ( P <0.001). Incidence of CDA for radiculopathy increased from 57% to 69% ( P <0.001), myelopathy increased from 23% to 78% ( P <0.001), and spondylosis without radiculopathy or myelopathy decreased from 19% to 3% ( P <0.001). There were increased incidences of ankylosing spondylitis (0.4% to 2.8%, P =0.007), long-term steroid use (1% to 2%, P =0.039), morbid obesity (2% to 6%, P =0.019), and osteoporosis (1% to 5%, P =0.014). The incidence of hybrid CDA and anterior cervical discectomy and fusion (ACDF) decreased from 28% to 23% ( P =0.007). CONCLUSION: From 2009 to 2019, the number of CDA performed in older patients increased. An increase in the use of CDA for the treatment of myelopathy and radiculopathy and a decrease in the treatment of isolated cervical spondylosis was observed. The proportion of CDA performed in patients with original IDE trial "contraindications" increased. Further research into the efficacy of CDA for patients with contraindications is warranted.


Asunto(s)
Vértebras Cervicales , Humanos , Vértebras Cervicales/cirugía , Masculino , Femenino , Anciano , Artroplastia , Persona de Mediana Edad , Estudios Transversales , Reeemplazo Total de Disco , Disco Intervertebral/cirugía , Contraindicaciones de los Procedimientos , Espondilosis/cirugía
20.
Neurosurgery ; 95(3): 627-633, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38551347

RESUMEN

BACKGROUND AND OBJECTIVES: Cervical disk arthroplasty (CDA) offers the advantage of motion preservation in the treatment of focal cervical pathology. At present, implant sizing is performed using subjective tactile feedback and imaging of trial cages. This study aims to construct interpretable machine learning (IML) models to accurately predict postoperative range of motion (ROM) and identify the optimal implant sizes that maximize ROM in patients undergoing CDA. METHODS: Adult patients who underwent CDA for single-level disease from 2012 to 2020 were identified. Patient demographics, comorbidities, and outcomes were collected, including symptoms, examination findings, subsidence, and reoperation. Affected disk height, healthy rostral disk height, and implant height were collected at sequential time points. Linear regression and IML models, including bagged regression tree, bagged multivariate adaptive regression spline, and k-nearest neighbors, were used to predict ROM change. Model performance was assessed by calculating the root mean square error (RMSE) between predicted and actual changes in ROM in the validation cohort. Variable importance was assessed using RMSE loss. Area under the curve analyses were performed to identify the ideal implant size cutoffs in predicting improved ROM. RESULTS: Forty-seven patients were included. The average RMSE between predicted and actual ROM was 7.6° (range: 5.8-10.1) in the k-nearest neighbors model, 7.8° (range: 6.5-10.0) in the bagged regression tree model, 7.8° (range: 6.2-10.0) in the bagged multivariate adaptive regression spline model, and 15.8° (range: 14.3-17.5°) in a linear regression model. In the highest-performing IML model, graft size was the most important predictor with RMSE loss of 6.2, followed by age (RMSE loss = 5.9) and preoperative caudal disk height (RMSE loss = 5.8). Implant size at 110% of the normal adjacent disk height was the optimal cutoff associated with improved ROM. CONCLUSION: IML models can reliably predict change in ROM after CDA within an average of 7.6 degrees of error. Implants sized comparably with the healthy adjacent disk may maximize ROM.


Asunto(s)
Vértebras Cervicales , Aprendizaje Automático , Rango del Movimiento Articular , Humanos , Femenino , Masculino , Persona de Mediana Edad , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Adulto , Rango del Movimiento Articular/fisiología , Artroplastia/métodos , Prótesis e Implantes , Disco Intervertebral/cirugía , Disco Intervertebral/diagnóstico por imagen , Estudios Retrospectivos , Anciano , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA