Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 483
Filtrar
1.
BMJ Open Qual ; 13(3)2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39117394

RESUMEN

BACKGROUND: The assessment and management of totally implanted vascular access devices (TIVAD) prior to the administration of medications/fluids are vital to ensuring the risk of harm is mitigated. While numerous guidelines exist for the insertion and management of TIVAD, the level of evidence and external validity to support these guidelines is lacking. OBJECTIVES: The purpose of this study was to identify factors associated with suboptimal TIVAD placement and with failure of TIVAD. METHODS: A retrospective case-control study (n=80) was conducted at a regional hospital and health service in Australia. Binomial logistic regression analysis was performed using a backward selection approach to establish variables associated suboptimal TIVAD placement and with TIVAD failure. FINDINGS: Significant associations were identified between the patient's primary diagnosis and suboptimal TIVAD insertion. Specifically, a prior diagnosis of breast cancer was associated with a decreased probability of optimal TIVAD tip placement (OR=0.236 (95% CI 0.058 to 0.960), p=0.044). A statistically significant association between TIVAD failure and the log of the heparinised saline flush rate and rate of undocumented flushes was also established. Further research is needed to identify and assess whether modification of these variables improves initial totally implantable venous access ports placement and risk of subsequent failure.


Asunto(s)
Dispositivos de Acceso Vascular , Humanos , Estudios Retrospectivos , Estudios de Casos y Controles , Femenino , Masculino , Persona de Mediana Edad , Anciano , Dispositivos de Acceso Vascular/normas , Dispositivos de Acceso Vascular/estadística & datos numéricos , Dispositivos de Acceso Vascular/efectos adversos , Australia , Servicios de Salud Rural/estadística & datos numéricos , Servicios de Salud Rural/normas , Factores de Riesgo , Adulto , Anciano de 80 o más Años , Modelos Logísticos
2.
Medicina (Kaunas) ; 60(7)2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-39064522

RESUMEN

A vessel port, implanted into the central venous system, is used for long-term intravenous drug administration in oncology patients. Although essential for frequent chemotherapy and other treatments, ports can lead to complications such as infection and thrombosis. This article discusses a rare but serious complication: the displacement of a catheter fragment. A 67-year-old gastric cancer patient, experienced malignant recurrence with jaundice and bile duct infiltration post Roux-Y subtotal gastrectomy and D2 lymphadenectomy. After nine cycles of chemotherapy, a catheter fragment from the venous port detached and lodged in a branch of the pulmonary artery in segment VIII of the right lung. Thoracotomy was performed to remove the foreign body. Our aim is to report on the surgical treatment of a displaced detached catheter and to raise awareness about the potential rare complications associated with the use of vascular ports in patients undergoing chronic oncological treatment. Additionally, we screened the PubMed database for similar surgical treatment reports and compared the collected data. Venous port malfunction or non-specific patient symptoms may indicate rare complications, such as port component detachment, necessitating a multidisciplinary approach for prompt diagnosis and management in oncological patients.


Asunto(s)
Arteria Pulmonar , Humanos , Anciano , Arteria Pulmonar/cirugía , Masculino , Neoplasias Gástricas/cirugía , Dispositivos de Acceso Vascular/efectos adversos , Gastrectomía/efectos adversos , Gastrectomía/métodos
3.
Br J Nurs ; 33(7): S18-S26, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38578942

RESUMEN

Occasionally, the administration of intravenous (IV) therapies can go wrong. Infiltration or extravasation is a complication when a drug or IV therapy leaks into the tissues surrounding the vascular access device. Extravasation can cause serious and often life-changing injuries. Extravasation is often associated with systemic anti-cancer therapy but non-chemotherapy drugs have been reported as having a greater risk of serious complications. This study outlines the first UK Infusion unit evaluation of the ivWatch infusion monitoring device which was undertaken from August 2023 to January 2024. Out of 2254 infusions monitored with ivWatch, the device prevented 122 cases of infiltration and extravasation from causing any harm to the patient, corresponding to a 5.4% 'check IV' notification rate.


Asunto(s)
Cateterismo Periférico , Atención de Enfermería , Dispositivos de Acceso Vascular , Humanos , Infusiones Intravenosas , Extravasación de Materiales Terapéuticos y Diagnósticos , Dispositivos de Acceso Vascular/efectos adversos , Cateterismo Periférico/efectos adversos
4.
Pediatr Res ; 96(1): 25-26, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38443522

RESUMEN

This article discusses the challenges in balancing the utility and harm associated with pediatric medical devices. Takashima et al. explored the prevalence and complications of invasive devices across three Australian pediatric tertiary hospitals and reported a high prevalence of complications, particularly with vascular access devices. We also highlight the need to pay attention to the use of these devices, particularly intravenous catheters, and the importance of a culture of patient safety in healthcare systems. We emphasize the need for a nuanced approach that carefully weighs the benefits against potential risks and encourages collaboration among stakeholders to establish robust regulatory frameworks and prioritize the safety and well-being of pediatric patients. Finally, we conclude by advocating the involvement of parents and families in gathering information about hospital safety incidents and fostering a culture of safety that supports reporting, flexibility, and learning. IMPACT: Reporting adverse events and their consequences is essential in the strategy to prevent them, allowing comparison with national or international standards, and identifying indicators to optimize and harbor the possibility of determining improvement measures that pursue a multifactorial approach and are cost-effective. Our comment advocates limiting the prevalence of medical invasive devices and their consequences by reviewing their epidemiology. Although advancements in medical technology have undoubtedly improved the diagnostic and therapeutic possibilities, the delicate balance between device utility and potential harm necessitates careful consideration.


Asunto(s)
Seguridad del Paciente , Humanos , Niño , Australia , Pediatría , Equipos y Suministros/efectos adversos , Atención a la Salud , Dispositivos de Acceso Vascular/efectos adversos
5.
Crit Rev Oncol Hematol ; 196: 104277, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38492760

RESUMEN

BACKGROUND: Patients with cancer can expect to receive numerous invasive vascular access procedures for intravenous therapy and clinical diagnostics. Due to the increased incidence and prevalence of cancer globally there will be significantly more people who require first-line intravenous chemotherapy over the next ten years. METHODS: Our objective was to determine the types of evidence that exist for the vascular access device (VAD) type for the delivery of systemic anti-cancer therapy (SACT) in cancer patients. We used JBI scoping review methodology to identify the types of VADs used for SACT and with a specific search strategy included articles from 2012-2022 published in the English language. We identify (i) type of VADs used for SACT delivery (ii) the type of insertion and post-insertion complications (iii) the geographical location and clinical environment (iv) and whether VAD choice impacts on quality of life (QOL). Findings were presented using the PAGER framework. MAIN FINDINGS: Our search strategy identified 10,390 titles, of these, 5318 duplicates were removed. The remaining 5072 sources were screened for eligibility, 240 articles met the inclusion criteria. The most common design include retrospective study designs (n = 91) followed by prospective study designs (n = 31). We found 28 interventional studies with 21 registered in a clinical trial registry and identified no core outcome sets papers specific to VAD for SACT. The most prevalent publications were those that featured two or more VAD types (n = 70), followed by tunnelled intravenous VADs (n = 67). Of 38 unique complications identified, the most frequent catheter related complication was catheter related thrombosis (n = 178, 74%), followed by infection (n = 170, 71%). The county where the most publications originated from was China (n = 62) with one randomized controlled multicenter study from a comprehensive cancer centre. Of the thirty three studies that included QOL we found 4 which reported on body image. No QOL measurement tools specific to the process of SACT administration via VAD are available INTERPRETATION: Our findings suggest a systematic review and meta-analysis of VAD use for intravenous SACT can be considered. However, the development of a core outcome set for SACT should be prioritised. Funding for high quality programs of research for VAD in cancer are needed. Comprehensive cancer centres should lead this research agenda.


Asunto(s)
Antineoplásicos , Neoplasias , Dispositivos de Acceso Vascular , Humanos , Neoplasias/tratamiento farmacológico , Dispositivos de Acceso Vascular/efectos adversos , Antineoplásicos/efectos adversos , Antineoplásicos/administración & dosificación , Antineoplásicos/uso terapéutico , Calidad de Vida
6.
Pediatr Res ; 96(1): 148-158, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38200324

RESUMEN

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.


Asunto(s)
Centros de Atención Terciaria , Humanos , Niño , Masculino , Femenino , Preescolar , Prevalencia , Lactante , Australia/epidemiología , Adolescente , Falla de Equipo/estadística & datos numéricos , Dispositivos de Acceso Vascular/efectos adversos , Recién Nacido , Encuestas y Cuestionarios , Hospitales Pediátricos
7.
Infect Control Hosp Epidemiol ; 45(6): 698-702, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38272652

RESUMEN

OBJECTIVE: Port-a-caths are implanted intravascular chest ports that enable venous access. With more port placements performed by interventional radiologists, it is important to discern differences in infection and complication rates between double- and single-lumen ports. METHODS: We retrospectively reviewed 1,385 port placements over 2 years at the University of Miami. Patients were grouped by single- or double-lumen ports. Data on duration of catheter stay, bloodstream infections, malfunctions, and other complications (fibrin sheath, thrombosis, catheter malposition) were collected. Multivariate Cox regression was performed to identify variables predicting port infection. RESULTS: The mean patient age was 58.8 years; the mean BMI was 26.9 kg/m2; and 61.5% of these patients were female. Our search revealed 791 double-lumen ports (57.1%) and 594 single-lumen ports (42.9%). The median follow-up was 668 days (range, 2-1,297). Double-lumen ports were associated with significantly higher rates of bacteremia (2.78% vs 0.84%; P = .02), port malfunction (8.3% vs 2.0%; P < .001), fibrin sheath formation (2.2% vs 0.5%; P < .02), catheter tip malposition (1.0% vs 0; P = .01), and catheter-associated thrombosis (1.4% vs 0; P = .003). Multivariate Cox regression analysis, after adjusting for other variables, showed that double-lumen chest ports had 2.98 times (95% confidence interval, 1.12-7.94) the hazard rate of single-lumen ports for developing bloodstream infection (P = .029). CONCLUSIONS: Double-lumen chest ports are associated with increased risk for bloodstream infection, malfunction, fibrin sheath formation, catheter tip malposition, and catheter-associated thrombosis. Interventional radiologists may consider placing single-lumen ports if clinically feasible; however, future studies are needed to determine clinical significance. The study limitations included the retrospective study design and the potential loss of patient follow-up.


Asunto(s)
Bacteriemia , Dispositivos de Acceso Vascular , Femenino , Persona de Mediana Edad , Bacteriemia/epidemiología , Infecciones Relacionadas con Catéteres/epidemiología , Falla de Equipo/estadística & datos numéricos , Análisis Multivariante , Radiólogos , Estudios Retrospectivos , Trombosis/epidemiología , Dispositivos de Acceso Vascular/efectos adversos , Dispositivos de Acceso Vascular/microbiología , Humanos , Masculino
8.
Br J Nurs ; 33(2): S12-S19, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38271042

RESUMEN

Vascular access continues to be a key factor for the reliable and safe delivery of intravenous (IV) therapy to patients in any healthcare setting. Clinical guidelines advocate for the right vascular access device selection, in order to reduce avoidable complications, eg multiple stabs, phlebitis, thrombophlebitis, insertion site infection, and blood stream infection, while improving efficiency and reducing costs. Peripheral intravenous catheters or cannulas (PIVCs) remain widely used for gaining vascular access in all clinical settings, with both adults and children, because they provide a relatively cheap and simple way to provide blood sampling and the prompt administration of IV medications. Although safe and easy to insert, PIVCs present with associated risks that can be costly to the organisation. The case studies included with this article introduce Nipro's Safetouch Cath Winged with Injection Port as a new cost-effective choice of PIVC, which is now available from NHS Supply Chain.


Asunto(s)
Cateterismo Periférico , Flebitis , Dispositivos de Acceso Vascular , Adulto , Niño , Humanos , Cánula/efectos adversos , Cateterismo Periférico/efectos adversos , Flebitis/etiología , Dispositivos de Acceso Vascular/efectos adversos , Remoción de Dispositivos
12.
ANZ J Surg ; 93(6): 1532-1535, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36772890

RESUMEN

BACKGROUND: Accurate placement of central venous access devices is important to avoid complications such as infection, thrombosis and migration. This audit aims to determine if there is a difference in complication rates and accuracy of tip position between two different intravenous jugular (IVJ) port device insertion techniques: fixation of port first (PF) versus tip first (TF). METHODS: Patients who underwent port device insertions from 2019 to 2021 at the Cairns Hospital were identified from the Australia Vascular Audit database. The primary outcome of accurate catheter tip placement (based on radiological criteria), secondary outcomes of line infection, thrombosis and other outcomes such as removal rates were gathered and compared between the 2 groups of port first (PF) versus tip first (TF) insertion. RESULTS: Two-hundred and twenty-seven patients underwent port device insertions during the period of interest. 98 (43.2%) patients had a PF insertion technique and 129 (56.8%) had a TF insertion technique. In the PF group, 81.6% (P < 0.05) of lines were accurately placed compared to 69.8% (P < 0.05) in the TF group. The line related thrombosis rate was 1% (P < 0.05) in the PF group compared to 6.2% (P < 0.05) in the TF group. Rate of line infections in the PF group was 5.1% (P = 0.92) compared to 6.2% (P = 0.92) in the TF group. CONCLUSION: The port first technique for IVJ port device placement was associated with higher accuracy and lower thrombosis rates and this was statistically significant. Further studies should involve larger multicentre populations to compare results between practitioners.


Asunto(s)
Cateterismo Venoso Central , Trombosis , Dispositivos de Acceso Vascular , Humanos , Dispositivos de Acceso Vascular/efectos adversos , Trombosis/epidemiología , Trombosis/etiología , Trombosis/prevención & control , Remoción de Dispositivos/efectos adversos , Catéteres/efectos adversos , Catéteres de Permanencia/efectos adversos , Estudios Retrospectivos
13.
Nephrology (Carlton) ; 28(4): 249-253, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36715242

RESUMEN

Catheter-related bloodstream infection (CRBI) is an important complication of catheter use for haemodialysis, but it remains unclear whether clinical outcomes following CRBI are influenced by organism type. This study aims to compare clinical outcomes following CRBI from Gram-positive and non-Gram-positive organisms. This was a retrospective cohort study of patients with kidney failure receiving haemodialysis (HD) via vascular catheters who had a documented episode of CRBI in Western Australia between 2005 and 2018. The associations between organism type, likelihood of hospitalization, catheter removal and death from CRBI were examined using adjusted logistic regression models. There were 111 episodes of CRBI in 99 patients (6.1 episodes per 1000-catheter-days at risk). Of the study cohort, 53 (48%) were male and 38 (34%) identified as Aboriginal or Torres Strait Islander. Gram-positive organisms were identified in 73 (66%) CRBI episodes, most commonly Staphylococcus aureus. Of those with non-Gram-positive CRBI, 9 (24%) were attributed to Pseudomonas aeruginosa. One-hundred and two (92%) episodes of CRBI required hospitalization and 15 (13%) patients died from CRBI. Compared with non-Gram-positive CRBI, Gram-positive CRBI was associated with an increased risk of hospitalization and catheter removal, with adjusted odds ratio of 9.34 (95% CI 1.28-68.03) and 3.47 (95% CI 1.25-9.67), respectively. There was no association between organism type and death from CRBI. Staphylococcus aureus remains the most common organism causing CRBI in HD patients. CRBI is associated with substantial morbidity, particularly CRBI attributed to Gram-positive organisms.


Asunto(s)
Infecciones Relacionadas con Catéteres , Diálisis Renal , Dispositivos de Acceso Vascular , Femenino , Humanos , Masculino , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/terapia , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Infecciones Estafilocócicas , Dispositivos de Acceso Vascular/efectos adversos , Australia Occidental/epidemiología
14.
J Vasc Access ; 24(3): 502-506, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-34396820

RESUMEN

Regular flushing and locking of totally implantable venous access devices (TIVADs) is recommended to maintain their patency when not in use. In this case report, a 73-year-old male patient received radical resection for rectal carcinoma in January 2010. A TIVAD was implanted in 2014 and a total of 12 rounds of chemotherapy of FOLFIRI was completed in 2015. During the period from 2015 to 2020, the patient never used or conducted the monthly infusion port flushing because of the inconvenience, the COVID-19 pandemic, and so on. On 18th April 2020, the patient was admitted to the radiotherapy department of Yiwu Central Hospital. The nurse evaluated the TIVAD upon admission, finding that the skin around the reservoir was normal without any sign of infection as erythema or induration of the skin overlying the implantable port but there was intraluminal occlusion of the devices. In order to re-access the catheter, discussion of a MDT was performed and several days of unremitting efforts were tried. Gratifyingly, the patient's port was re-accessed successfully without any adverse reactions. This is a rare infusion port that has not been used and maintained for 5 years. For the port that has not been used and maintained for a long time up to 5 years, the medical staff should not give up easily. During the COVID-19 pandemic, prolonging the flushing interval of TIVADs can be an optimal clinical strategy without negative outcomes.


Asunto(s)
COVID-19 , Cateterismo Venoso Central , Dispositivos de Acceso Vascular , Masculino , Humanos , Anciano , Pandemias , Catéteres de Permanencia/efectos adversos , Factores de Tiempo , Dispositivos de Acceso Vascular/efectos adversos , Cateterismo Venoso Central/efectos adversos
15.
Med J Malaysia ; 77(5): 590-596, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36169071

RESUMEN

INTRODUCTION: During the COVID-19 pandemic, bloodstream infection (BSI) rates were substantially rising in Sungai Buloh Hospital (HSB). It is believed that the COVID-19 pandemic has had an adverse impact on BSI incidence caused by contaminated periphery vascular catheters (PVCs). The study's objective is to reduce the BSI rates in HSB by improving adherence to the PVC care bundle via the Plan-Do-Study-Act (PDSA) approach. MATERIALS AND METHODS: A quality improvement (QI) project was employed over four months, from June to September 2021, during the COVID-19 pandemic in HSB. All adults hospitalised for COVID-19 with intravenous lines were subjected to data collection. A baseline audit was conducted to study BSI incidence from April to May 2021. Implementation was carried out by PDSA cycles and data on BSI rates per 100 admissions was described using a monthly run chart. RESULTS: At baseline, the BSI rate per 100 admissions was 5.44 before implementing our QI project. Initial changes via PDSA cycles did not bring significant improvements to BSI rates and a rising trend in BSI rates was observed after two PDSA cycles. Further audits identified the problem of noncompliance with the practice of aseptic non-touch technique (ANTT) and a lack of effective leadership in implementing the PVC care bundle. The third PDSA cycle focused on adopting practical leadership skills among senior clinicians to ensure compliance with the prevention bundle and to encourage the use of ultrasound guidance for difficult line insertion. After the third PDSA cycle, the BSI rate per 100 admissions was reduced from 6.41 to 4.34 (p < 0.05). The BSI rates continued to decline down the line for another five months. CONCLUSION: Through QI initiatives, the risk of BSI can be significantly reduced.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , COVID-19 , Paquetes de Atención al Paciente , Sepsis , Dispositivos de Acceso Vascular , Adulto , Humanos , COVID-19/epidemiología , COVID-19/prevención & control , Pandemias/prevención & control , Paquetes de Atención al Paciente/efectos adversos , Mejoramiento de la Calidad , Sepsis/etiología , Dispositivos de Acceso Vascular/efectos adversos
16.
Open Vet J ; 12(3): 356-359, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35821776

RESUMEN

Background: Portal vein thrombosis is a disease with potentially deleterious outcomes including portal vein hypertension and intestinal infarction. The factors contributing is various; however, dogs with with acute portal vein thrombosis or multiple thromboses are less likely to survive. Therefore, acute development of portal hypertension has a requires an immediate treatment. Case Description: A 10-year-old Dalmatian was referred for syncope and azotemia, hyperammonemia. After each examinations including computed tomography scan, we diagnosed with acute portal vein thrombosis with unknown cause. A portal vein port was inserted to prevent and control the portal vein thrombus. The port was placed in abdomen subcutaneously after the position of the catheter were stabilized. Low-molecular-weight heparin was injected from the port to manage thrombosis after the operation. This case responded well to this treatment. Syncope and azotemia, hyperammonemia resolved and no relapse of thrombosis was found 6 months after the operation. Conclusion: Implantable vascular access port is a drug delivery system with the advantage of dealing with treatment-resistant acute portal vein thrombosis.


Asunto(s)
Azotemia , Enfermedades de los Perros , Hiperamonemia , Hipertensión Portal , Dispositivos de Acceso Vascular , Trombosis de la Vena , Animales , Azotemia/complicaciones , Azotemia/veterinaria , Enfermedades de los Perros/tratamiento farmacológico , Enfermedades de los Perros/cirugía , Perros , Hiperamonemia/complicaciones , Hiperamonemia/veterinaria , Hipertensión Portal/veterinaria , Vena Porta/cirugía , Síncope/complicaciones , Síncope/veterinaria , Dispositivos de Acceso Vascular/efectos adversos , Trombosis de la Vena/diagnóstico , Trombosis de la Vena/tratamiento farmacológico , Trombosis de la Vena/veterinaria
18.
Eur J Pediatr ; 181(8): 3031-3038, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35652985

RESUMEN

The risk for venous thromboembolism (VTE) is considered to be low in the general paediatric intensive care unit (PICU) population, and pharmacological thromboprophylaxis is not routinely used. PICU patients considered at high-risk of VTE could possibly benefit from pharmacological thromboprophylaxis, but the incidence of VTE in this group of patients is unclear. This was an observational, prospective study at a tertiary multi-disciplinary paediatric hospital. We used comprehensive ultrasonography screening for VTE in critically ill children with multiple risk factors for VTE. Patients admitted to PICU ≥ 72 h and with ≥ two risk factors for VTE were included. Patients receiving pharmacological thromboprophylaxis during their entire PICU stay were excluded. The primary outcome of the study was VTEs not related to the use of a CVC. Ultrasonography screening of the great veins was performed at PICU discharge. Seventy patients with median (interquartile range) 3 (2-4) risk factors for VTE were evaluated. Median age was 0.3 years (0.03-4.3) and median PICU length of stay 9 days (5-17). Regarding the primary outcome, no symptomatic VTEs occurred and no asymptomatic VTEs were found on ultrasonography screening, resulting in an incidence of VTEs not related to a vascular catheter of 0% (95% CI: 0-5.1%). CONCLUSION: Our results indicate that VTEs not related to a vascular catheter are a rare event even in a selected group of severely ill small children considered to be at high risk of VTE. WHAT IS KNOWN: • Children in the PICU often have several risk factors for venous thromboembolism (VTE). • The incidence of VTE in PICU patients is highly uncertain, and there are no evidence-based guidelines regarding VTE prophylaxis. WHAT IS NEW: • This study found an incidence of VTEs not related to a vascular catheter of 0% (95% CI: 0-5.1%). • This indicates that such VTE events are rare even in PICU patients with multiple risk factors for VTE.


Asunto(s)
Dispositivos de Acceso Vascular , Tromboembolia Venosa , Trombosis de la Vena , Anticoagulantes/uso terapéutico , Niño , Enfermedad Crítica , Humanos , Incidencia , Lactante , Estudios Prospectivos , Factores de Riesgo , Dispositivos de Acceso Vascular/efectos adversos , Tromboembolia Venosa/diagnóstico por imagen , Tromboembolia Venosa/epidemiología , Tromboembolia Venosa/etiología , Trombosis de la Vena/etiología
19.
Langenbecks Arch Surg ; 407(3): 1257-1262, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35257222

RESUMEN

PURPOSE: A totally implantable vascular access port (TIVAP) is commonly required in cancer patients. Possible adverse events after TIVAP implantation include surgical site infection (SSI) and port-related bacteremia. This study examined whether adhesive surgical drapes can reduce the risk of SSI. METHODS: A total of 100 mostly cancer patients were randomized into two groups before undergoing TIVAP implantation by surgical cut-down. In one group, an adhesive, non-impregnated drape was applied to the skin prior to incision, while the control group underwent surgery without a drape. Swabs were taken from the surgical site and sent for microbiologic testing. SSI rates were compared between groups. RESULTS: No SSI occurred within 30 days after surgery. In each group, two patients died. There were 5 complications (port thrombosis, port dislocation, two cases of pneumothorax, skin allergy), all in the intervention group (p = 0.056). Using the incision drape prolonged procedure time by + 5 min (95% CI - 1 to + 10, p = 0.125). Microbiologic swab testing failed to detect any effect of the incision drape. CONCLUSIONS: Plastic adhesive skin drapes may be unnecessary in cancer patients who undergo surgical implantation of a TIVAP.


Asunto(s)
Neoplasias , Paños Quirúrgicos , Dispositivos de Acceso Vascular , Adhesivos , Humanos , Proyectos Piloto , Plásticos , Paños Quirúrgicos/efectos adversos , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/prevención & control , Dispositivos de Acceso Vascular/efectos adversos
20.
Comput Math Methods Med ; 2022: 6470576, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35096133

RESUMEN

This study was to explore the application value for central venous stenosis and occlusion in hemodialysis patients under the CT angiography based on intelligent segmentation algorithm, so that patients can survive better. Spiral CT was used to examine upper limb swelling in 62 uremic hemodialysis patients at a speed of 3.8 mL/s. Nonionic iodine contrast agent was injected around the contralateral limb. The total dosage of 90-102 mL, it was scanned by intelligent trigger technology. The trigger scanning threshold was set. The monitoring point was located in the superior vena cava. CT with convolutional neural network intelligent segmentation algorithm was used to process image data. Finally, the quality of life and related biochemical levels of patients before and after hemodialysis were detected. Under the CT angiography of intelligent segmentation algorithm, 77 stenoses were found in 62 uremic patients, including 48 stenoses of the brachial vein and 17 stenoses of the superior vena cava. The correlation coefficient between CT angiography and digital subtraction angiography (DSA) imaging results of intelligent segmentation algorithm was 0.411. Segmentation effect of the algorithm in this study: automatic segmentation accuracy was greater than 79%. After hemodialysis treatment, the scores of physical fitness, pain, social function, and energy status of patients were significantly increased compared with those before treatment, and the levels of albumin, serum phosphorus, and parathyroid hormone were significantly decreased (P < 0.05). In summary, CT angiography with intelligent segmentation algorithm can obtain clear, intuitive, and complete vascular walking images, and better display subclavian vein, brachiocephalic vein, and superior vena cava. It can provide more valuable support for surgical intervention and has certain application value for better survival of hemodialysis patients.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada/métodos , Diálisis Renal , Adulto , Anciano , Angiografía de Substracción Digital/métodos , Angiografía de Substracción Digital/estadística & datos numéricos , Brazo/diagnóstico por imagen , Biología Computacional , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Edema/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Redes Neurales de la Computación , Diálisis Renal/efectos adversos , Trombosis Venosa Profunda de la Extremidad Superior/diagnóstico por imagen , Trombosis Venosa Profunda de la Extremidad Superior/etiología , Uremia/diagnóstico por imagen , Uremia/terapia , Dispositivos de Acceso Vascular/efectos adversos , Vena Cava Superior/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA