Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59.373
Filtrar
1.
Gulf J Oncolog ; 1(45): 69-74, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774935

RESUMEN

BACKGROUND: In management of Carcinoma Cervix, Brachytherapy plays a crucial role. Most commonly used technique is Intracavitary Brachytherapy (ICBT). In cases where ICBT is not technically feasible or it may result in suboptimal dose distribution, Interstitial Brachytherapy (ISBT) is recommended. With this study we wanted to study the clinical outcome and dosimetric details of interstitial brachytherapy in gynecological cancers. MATERIALS & METHODS: We analysed clinicaloutcome and dosimetric details of interstitial brachytherapy (ISBT) done for gynecological malignancies in our institute during the period 1st January 2013 to 31st December 2020. RESULTS: Total of 42 interstitial brachytherapy (ISBT) details were analysed.37 patients had Carcinoma Cervix and 5 patients had Carcinoma Vagina. In the majority of the patients, ISBT dosage schedule was three fractions 7Gy each. D2cc to rectum, bladder, sigmoid and bowel were 4.88 Gy, 5.62 Gy, 3.57 Gy and 2.47 Gy respectively. Mean CTV volume was 129.89 cc. EQD2 dose to CTV combining EBRT and ISBT dose was 85.88 Gy. D90 and D100 to CTV from ISBT were 111.96% and 68.21 % of prescribed dose respectively. Grade III/IV toxicities were seen in 5 (12%) patients. Local control rates at 1year &2 years were 88% & 85.7% respectively. DFS at 1 year, 2 years and 3 years were 80.7%, 72.3% and 65.7% respectively. OS at 1year, 2 years, 4 years and 5 years were 92.5%, 65.5%, 59.5% and 42.3% respectively. CONCLUSION: 3D imagebased dosimetry with CT based planning using MUPIT implant is a feasible option for gynecological malignancies warranting interstitial brachytherapy. In view of good clinical outcomes in terms of toxicity profile, Local control, DFS and OS with acceptable GEC-ESTRO dosimetric data, we recommend routine use interstitial brachytherapy if facilities are available and in clinical situations were ISBT is indicated.


Asunto(s)
Braquiterapia , Neoplasias de los Genitales Femeninos , Humanos , Femenino , Braquiterapia/métodos , Neoplasias de los Genitales Femeninos/radioterapia , Persona de Mediana Edad , Dosificación Radioterapéutica , Adulto , Anciano , Radiometría/métodos , Neoplasias del Cuello Uterino/radioterapia , Resultado del Tratamiento
2.
Gulf J Oncolog ; 1(45): 94-99, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774938

RESUMEN

PURPOSE: We report the use of online adaptive radiotherapy (OART) aiming to improve dosimetric parameters in the prostate cancer patient who had lower urinary tract symptoms that caused him not to adhere to the standard bladder filling protocol. METHODS AND MATERIALS: The reference treatment plan for adaptive radiotherapy plan was generated for the pelvis and the solitary bony lesion using the Ethos treatment planning system. For each treatment session, high-quality iterative reconstructed cone beam CT (CBCT) images were acquired, and the system automatically generated an optimal adaptive plan after verification of contours. Image-guided RT (IGRT) plans were also created using the reference plan recalculated on the CBCT scan and were compared with adaptive plans. RESULTS: The reference bladder volume in the planning CT scan was 173 cc, and the mean bladder volume difference over the course was 25.4% ± 16.6%. The ART offered superior target coverage for PTV 70 Gy over online IGRT (V95: 90.5 ± 3.2 % Vs 97.3 ± 0.4%; p=0.000) and the bladder was also better spared from the high dose (V65 Gy: 17.9 ± 9.1% vs 14.8 ± 3.6%; p=0.03). However, the mean rectum V65 doses were very similar in both plans. CONCLUSION: Managing the inconsistent bladder volume was feasible in the prostate cancer patient using the CBCT-guided OART and our analysis confirmed that adaptive plans offered better target coverage while sparing the bladder from high radiation doses in comparison to online IGRT plans. KEY WORDS: radiotherapy, CBCT, online adaptive radiotherapy, image-guided RT.


Asunto(s)
Neoplasias de la Próstata , Planificación de la Radioterapia Asistida por Computador , Vejiga Urinaria , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Planificación de la Radioterapia Asistida por Computador/métodos , Vejiga Urinaria/patología , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada de Haz Cónico/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Anciano
4.
Biomed Phys Eng Express ; 10(4)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38697028

RESUMEN

Background and purpose. To investigate models developed using radiomic and dosiomic (multi-omics) features from planning and treatment imaging for late patient-reported dysphagia in head and neck radiotherapy.Materials and methods. Training (n = 64) and testing (n = 23) cohorts of head and neck cancer patients treated with curative intent chemo-radiotherapy with a follow-up time greater than 12 months were retrospectively examined. Patients completed the MD Anderson Dysphagia Inventory and a composite score ≤60 was interpreted as patient-reported dysphagia. A chart review collected baseline dysphagia and clinical factors. Multi-omic features were extracted from planning and last synthetic CT images using the pharyngeal constrictor muscle contours as a region of interest. Late patient-reported dysphagia models were developed using a random forest backbone, with feature selection and up-sampling methods to account for the imbalanced data. Models were developed and validated for multi-omic feature combinations for both timepoints.Results. A clinical and radiomic feature model developed using the planning CT achieved good performance (validation: sensitivity = 80 ± 27% / balanced accuracy = 71 ± 23%, testing: sensitivity = 80 ± 10% / balanced accuracy = 73 ± 11%). The synthetic CT models did not show improvement over the plan CT multi-omics models, with poor reliability of the radiomic features on these images. Dosiomic features extracted from the synthetic CT showed promise in predicting late patient-reported dysphagia.Conclusion. Multi-omics models can predict late patient-reported dysphagia in head and neck radiotherapy patients. Synthetic CT dosiomic features show promise in developing successful models to account for changes in delivered dose distribution. Multi-center or prospective studies are required prior to clinical implementation of these models.


Asunto(s)
Trastornos de Deglución , Neoplasias de Cabeza y Cuello , Humanos , Trastornos de Deglución/etiología , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/complicaciones , Masculino , Persona de Mediana Edad , Femenino , Anciano , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Reproducibilidad de los Resultados , Dosificación Radioterapéutica , Medición de Resultados Informados por el Paciente , Multiómica
5.
Radiat Environ Biophys ; 63(2): 297-306, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38722389

RESUMEN

For locally advanced cervical cancer, the standard therapeutic approach involves concomitant chemoradiation therapy, supplemented by a brachytherapy boost. Moreover, an external beam radiotherapy (RT) boost should be considered for treating gross lymph node (LN) volumes. Two boost approaches exist with Volumetric Intensity Modulated Arc Therapy (VMAT): Sequential (SEQ) and Simultaneous Integrated Boost (SIB). This study undertakes a comprehensive dosimetric and radiobiological comparison between these two boost strategies. The study encompassed ten patients who underwent RT for cervical cancer with node-positive disease. Two sets of treatment plans were generated for each patient: SIB-VMAT and SEQ-VMAT. Dosimetric as well as radiobiological parameters including tumour control probability (TCP) and normal tissue complication probability (NTCP) were compared. Both techniques were analyzed for two different levels of LN involvement - only pelvic LNs and pelvic with para-aortic LNs. Statistical analysis was performed using SPSS software version 25.0. SIB-VMAT exhibited superior target coverage, yielding improved doses to the planning target volume (PTV) and gross tumour volume (GTV). Notably, SIB-VMAT plans displayed markedly superior dose conformity. While SEQ-VMAT displayed favorable organ sparing for femoral heads, SIB-VMAT appeared as the more efficient approach for mitigating bladder and bowel doses. TCP was significantly higher with SIB-VMAT, suggesting a higher likelihood of successful tumour control. Conversely, no statistically significant difference in NTCP was observed between the two techniques. This study's findings underscore the advantages of SIB-VMAT over SEQ-VMAT in terms of improved target coverage, dose conformity, and tumour control probability. In particular, SIB-VMAT demonstrated potential benefits for cases involving para-aortic nodes. It is concluded that SIB-VMAT should be the preferred approach in all cases of locally advanced cervical cancer.


Asunto(s)
Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Neoplasias del Cuello Uterino , Humanos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/patología , Femenino , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Metástasis Linfática/radioterapia
6.
Eur J Med Res ; 29(1): 282, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38735974

RESUMEN

BACKGROUND: Radiation induced acute skin toxicity (AST) is considered as a common side effect of breast radiation therapy. The goal of this study was to design dosiomics-based machine learning (ML) models for prediction of AST, to enable creating optimized treatment plans for high-risk individuals. METHODS: Dosiomics features extracted using Pyradiomics tool (v3.0.1), along with treatment plan-derived dose volume histograms (DVHs), and patient-specific treatment-related (PTR) data of breast cancer patients were used for modeling. Clinical scoring was done using the Common Terminology Criteria for Adverse Events (CTCAE) V4.0 criteria for skin-specific symptoms. The 52 breast cancer patients were grouped into AST 2 + (CTCAE ≥ 2) and AST 2 - (CTCAE < 2) toxicity grades to facilitate AST modeling. They were randomly divided into training (70%) and testing (30%) cohorts. Multiple prediction models were assessed through multivariate analysis, incorporating different combinations of feature groups (dosiomics, DVH, and PTR) individually and collectively. In total, seven unique combinations, along with seven classification algorithms, were considered after feature selection. The performance of each model was evaluated on the test group using the area under the receiver operating characteristic curve (AUC) and f1-score. Accuracy, precision, and recall of each model were also studied. Statistical analysis involved features differences between AST 2 - and AST 2 + groups and cutoff value calculations. RESULTS: Results showed that 44% of the patients developed AST 2 + after Tomotherapy. The dosiomics (DOS) model, developed using dosiomics features, exhibited a noteworthy improvement in AUC (up to 0.78), when spatial information is preserved in the dose distribution, compared to DVH features (up to 0.71). Furthermore, a baseline ML model created using only PTR features for comparison with DOS models showed the significance of dosiomics in early AST prediction. By employing the Extra Tree (ET) classifiers, the DOS + DVH + PTR model achieved a statistically significant improved performance in terms of AUC (0.83; 95% CI 0.71-0.90), accuracy (0.70), precision (0.74) and sensitivity (0.72) compared to other models. CONCLUSIONS: This study confirmed the benefit of dosiomics-based ML in the prediction of AST. However, the combination of dosiomics, DVH, and PTR yields significant improvement in AST prediction. The results of this study provide the opportunity for timely interventions to prevent the occurrence of radiation induced AST.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Automático , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Persona de Mediana Edad , Adulto , Anciano , Piel/efectos de la radiación , Piel/patología , Traumatismos por Radiación/etiología , Traumatismos por Radiación/diagnóstico , Dosificación Radioterapéutica
7.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 773-779, 2024 Apr 20.
Artículo en Chino | MEDLINE | ID: mdl-38708512

RESUMEN

OBJECTIVE: To investigate the dosimetric difference between manual and inverse optimization in 3-dimensional (3D) brachytherapy for gynecologic tumors. METHODS: This retrospective study was conducted among a total of 110 patients with gynecologic tumors undergoing intracavitary combined with interstitial brachytherapy or interstitial brachytherapy. Based on the original images, the brachytherapy plans were optimized for each patient using Gro, IPSA1, IPSA2 (with increased volumetric dose limits on the basis of IPSA1) and HIPO algorithms. The dose-volume histogram (DVH) parameters of the clinical target volume (CTV) including V200, V150, V100, D90, D98 and CI, and the dosimetric parameters D2cc, D1cc, and D0.1cc for the bladder, rectum, and sigmoid colon were compared among the 4 plans. RESULTS: Among the 4 plans, Gro optimization took the longest time, followed by HIPO, IPSA2 and IPSA1 optimization. The mean D90, D98, and V100 of HIPO plans were significantly higher than those of Gro and IPSA plans, and D90 and V100 of IPSA1, IPSA2 and HIPO plans were higher than those of Gro plans (P < 0.05), but the CI of the 4 plans were similar (P > 0.05). For the organs at risk (OARs), the HIPO plan had the lowest D2cc of the bladder and rectum; the bladder absorbed dose of Gro plans were significantly greater than those of IPSA1 and HIPO (P < 0.05). The D2cc and D1cc of the rectum in IPSA1, IPSA2 and HIPO plans were better than Gro (P < 0.05). The D2cc and D1cc of the sigmoid colon did not differ significantly among the 4 plans. CONCLUSION: Among the 4 algorithms, the HIPO algorithm can better improve dose coverage of the target and lower the radiation dose of the OARs, and is thus recommended for the initial plan optimization. Clinically, the combination of manual optimization can achieve more individualized dose distribution of the plan.


Asunto(s)
Algoritmos , Braquiterapia , Neoplasias de los Genitales Femeninos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Braquiterapia/métodos , Femenino , Estudios Retrospectivos , Neoplasias de los Genitales Femeninos/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos
8.
J Coll Physicians Surg Pak ; 34(5): 573-577, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38720219

RESUMEN

OBJECTIVE:  To compare the acute toxicities of two radiation treatment techniques, intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (3D-CRT) in localised prostate adenocarcinoma. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oncology, Dr. Ziauddin Hospital, Karachi, Pakistan, from July 2016 to June 2022. METHODOLOGY: Patients with localised prostate adenocarcinoma who underwent treatment using two different advanced radiotherapy techniques i.e., IMRT and 3D-CRT were recruited during the study period. They were followed up for six months for acute gastrointestinal (GI) and genitourinary (GU) adverse events (acute toxicities) related to both treatment modalities according to Modified radiation therapy oncology group (RTOG) criteria. The acute toxicities were assessed at the 2nd, 4th, and 6th week during treatment and at the 3rd and 6th month after treatment. RESULTS:  There were 78 patients, with 39 patients in each group. The mean age was 68 ± 10 years in the 3D-CRT and 68 ± 07 years in the IMRT group. Patients in the IMRT group exhibited markedly lower treatment-related acute GI and GU effects at the end of 4th and 6th weeks for anorectal pain (p = 0.04) and (p = 0.01) and burning micturition (p = 0.003) and (p = 0.01), respectively. Furthermore, at 3 months anorectal pain (p = 0.02), loose stools (p = 0.005), and burning micturition (p = 0.01) were present and at 6 months anorectal pain was (p = 0.01) still present. CONCLUSION: Radiation therapy modalities 3D-CRT and IMRT both showed acceptable toxicity profile in the management of localised prostate cancer, while IMRT group exhibited significantly lower treatment-related acute GI and GU effects. KEY WORDS: 3D-CRT (3-Dimensional Conformal Radiation Therapy), IMRT (Intensity-Modulated Radiation Therapy), Radiation toxicity.


Asunto(s)
Neoplasias de la Próstata , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Anciano , Radioterapia Conformacional/efectos adversos , Radioterapia Conformacional/métodos , Persona de Mediana Edad , Traumatismos por Radiación/etiología , Adenocarcinoma/radioterapia , Adenocarcinoma/patología , Pakistán , Dosificación Radioterapéutica
9.
Phys Med ; 121: 103360, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692114

RESUMEN

This paper reports the development of dosimeters based on plastic scintillating fibers imaged by a charge-coupled device camera, and their performance evaluation through irradiations with the electron Flash research accelerator located at the Centro Pisano Flash Radiotherapy. The dosimeter prototypes were composed of a piece of plastic scintillating fiber optically coupled to a clear optical fiber which transported the scintillation signal to the readout systems (an imaging system and a photodiode). The following properties were tested: linearity, capability to reconstruct the percentage depth dose curve in solid water and to sample in time the single beam pulse. The stem effect contribution was evaluated with three methods, and a proof-of-concept one-dimensional array was developed and tested for online beam profiling. Results show linearity up to 10 Gy per pulse, and good capability to reconstruct both the timing and spatial profiles of the beam, thus suggesting that plastic scintillating fibers may be good candidates for low-energy electron Flash dosimetry.


Asunto(s)
Electrones , Plásticos , Dosímetros de Radiación , Dosificación Radioterapéutica , Conteo por Cintilación , Electrones/uso terapéutico , Conteo por Cintilación/instrumentación , Radiometría/instrumentación
10.
Phys Med ; 121: 103367, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38701625

RESUMEN

PURPOSE: Diffusing alpha-emitters radiation therapy (DaRT) is a brachytherapy technique using α-particles to treat solid tumours. The high linear energy transfer (LET) and short range of α-particles make them good candidates for the targeted treatment of cancer. Treatment planning of DaRT requires a good understanding of the dose from α-particles and the other particles released in the 224Ra decay chain. METHODS: The Geant4 Monte Carlo toolkit has been used to simulate a DaRT seed to better understand the dose contribution from all particles and simulate the DNA damage due to this treatment. RESULTS: Close to the seed α-particles deliver the majority of dose, however at radial distances greater than 4 mm, the contribution of ß-particles is greater. The RBE has been estimated as a function of number of double strand breaks (DSBs) and complex DSBs. A maximum seed spacing of 5.5 mm and 6.5 mm was found to deliver at least 20 Gy RBE weighted dose between the seeds for RBEDSB and RBEcDSB respectively. CONCLUSIONS: The DNA damage changes with radial distance from the seed and has been found to become less complex with distance, which is potentially easier for the cell to repair. Close to the seed α-particles contribute the majority of dose, however the contribution from other particles cannot be neglected and may influence the choice of seed spacing.


Asunto(s)
Partículas alfa , Daño del ADN , Método de Montecarlo , Partículas alfa/uso terapéutico , Dosificación Radioterapéutica , Dosis de Radiación , Efectividad Biológica Relativa , Difusión , Braquiterapia/métodos , Humanos , Transferencia Lineal de Energía , Planificación de la Radioterapia Asistida por Computador/métodos , Roturas del ADN de Doble Cadena/efectos de la radiación
11.
Phys Med ; 121: 103364, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38701626

RESUMEN

PURPOSE: Test whether a well-grounded KBP model trained on moderately hypo-fractionated prostate treatments can be used to satisfactorily drive the optimization of SBRT prostate treatments. MATERIALS AND METHODS: A KBP model (SBRT-model) was developed, trained and validated using the first forty-seven clinically treated VMAT SBRT prostate plans (42.7 Gy/7fx or 36.25 Gy/5fx). The performance and robustness of this model were compared against a high-quality KBP-model (ST-model) that was already clinically adopted for hypo-fractionated (70 Gy/28fx and 60 Gy/20fx) prostate treatments. The two models were compared in terms of their predictions robustness, and the quality of their outcomes were evaluated against a set of reference clinical SBRT plans. Plan quality was assessed using DVH metrics, blinded clinical ranking, and a dedicated Plan Quality Metric algorithm. RESULTS: The plan libraries of the two models were found to share a high degree of anatomical similarity. The overall quality (APQM%) of the plans obtained both with the ST- and SBRT-models was compatible with that of the original clinical plans, namely (93.7 ± 4.1)% and (91.6 ± 3.9)% vs (92.8.9 ± 3.6)%. Plans obtained with the ST-model showed significantly higher target coverage (PTV V95%): (97.9 ± 0.8)% vs (97.1 ± 0.9)% (p < 0.05). Conversely, plans optimized following the SBRT-model showed a small but not-clinically relevant increase in OAR sparing. ST-model generally provided more reliable predictions than SBRT-model. Two radiation oncologists judged as equivalent the plans based on the KBP prediction, which was also judged better that reference clinical plans. CONCLUSION: A KBP model trained on moderately fractionated prostate treatment plans provided optimal SBRT prostate plans, with similar or larger plan quality than an embryonic SBRT-model based on a limited number of cases.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiocirugia/métodos , Masculino , Neoplasias de la Próstata/radioterapia , Bases del Conocimiento , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica
12.
Biomed Phys Eng Express ; 10(4)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38697044

RESUMEN

Objective.The aim of this work was to develop a Phase I control chart framework for the recently proposed multivariate risk-adjusted Hotelling'sT2chart. Although this control chart alone can identify most patients receiving extreme organ-at-risk (OAR) dose, it is restricted by underlying distributional assumptions, making it sensitive to extreme observations in the sample, as is typically found in radiotherapy plan quality data such as dose-volume histogram (DVH) points. This can lead to slightly poor-quality plans that should have been identified as out-of-control (OC) to be signaled in-control (IC).Approach. We develop a robust iterative control chart framework to identify all OC patients with abnormally high OAR dose and improve them via re-optimization to achieve an IC sample prior to establishing the Phase I control chart, which can be used to monitor future treatment plans.Main Results. Eighty head-and-neck patients were used in this study. After the first iteration, P14, P67, and P68 were detected as OC for high brainstem dose, warranting re-optimization aimed to reduce brainstem dose without worsening other planning criteria. The DVH and control chart were updated after re-optimization. On the second iteration, P14, P67, and P68 were IC, but P40 was identified as OC. After re-optimizing P40's plan and updating the DVH and control chart, P40 was IC, but P14* (P14's re-optimized plan) and P62 were flagged as OC. P14* could not be re-optimized without worsening target coverage, so only P62 was re-optimized. Ultimately, a fully IC sample was achieved. Multiple iterations were needed to identify and improve all OC patients, and to establish a more robust control limit to monitor future treatment plans.Significance. The iterative procedure resulted in a fully IC sample of patients. With this sample, a more robust Phase I control chart that can monitor OAR doses of new plans was established.


Asunto(s)
Órganos en Riesgo , Control de Calidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Algoritmos
13.
Cancer Med ; 13(10): e7127, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38770540

RESUMEN

BACKGROUND: To compare the clinical outcomes of two treatment modalities, initial surgery and primary definitive radiotherapy (RT), in Taiwanese patients diagnosed with cT1-2N0M0 oral cavity squamous cell carcinoma (OCSCC). METHODS: Between 2011 and 2019, we analyzed data for 13,542 cT1-2N0M0 patients who underwent initial surgery (n = 13,542) or definitive RT with a dosage of at least 6600 cGy (n = 145) for the treatment of OCSCC. To account for baseline differences, we employed propensity score (PS) matching, resulting in two well-balanced study groups (initial surgery, n = 580; definitive RT, n = 145). RESULTS: Before PS matching, the 5-year disease-specific survival (DSS) rates were 88% for the surgery group and 58% for the RT group. After PS matching, the 5-year DSS rates of the two groups were 86% and 58%, respectively. Similarly, the 5-year overall survival (OS) rates before PS matching were 80% for the surgery group and 36% for the RT group, whereas after PS matching, they were 73% and 36%, respectively. All these differences were statistically significant (p < 0.0001). A multivariable analysis identified treatment with RT, older age, stage II tumors, and a higher burden of comorbidities as independent risk factors for both DSS and OS. We also examined the 5-year outcomes for various subgroups (margin ≥5 mm, margin <5 mm, positive margins, RT combined with chemotherapy, and RT alone) as follows: DSS, 89%/88%/79%/63%/51%, respectively, p < 0.0001; OS, 82%/79%/68%/39%/32%, respectively, p < 0.0001. CONCLUSIONS: In Taiwanese patients with cT1-2N0M0 OCSCC, a remarkably low proportion (1.1%) completed definitive RT. A significant survival disparity of 30% was observed between patients who underwent initial surgery and those who received definitive RT. Interestingly, even patients from the surgical group with positive surgical margins exhibited a significantly superior survival compared to those in the definitive RT group.


Asunto(s)
Neoplasias de la Boca , Humanos , Masculino , Femenino , Neoplasias de la Boca/radioterapia , Neoplasias de la Boca/cirugía , Neoplasias de la Boca/mortalidad , Neoplasias de la Boca/patología , Persona de Mediana Edad , Anciano , Taiwán/epidemiología , Estadificación de Neoplasias , Dosificación Radioterapéutica , Resultado del Tratamiento , Puntaje de Propensión , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/mortalidad , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/patología , Adulto , Estudios Retrospectivos , Tasa de Supervivencia , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Carcinoma de Células Escamosas de Cabeza y Cuello/mortalidad , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía , Carcinoma de Células Escamosas de Cabeza y Cuello/patología
14.
Cancer Med ; 13(10): e7322, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38785309

RESUMEN

BACKGROUND AND PURPOSE: Respiratory movement has an important impact on the radiotherapy for lung tumor. Respiratory gating technology is helpful to improve the accuracy of target delineation. This study investigated the value of prospective and retrospective respiratory gating simulations in target delineation and radiotherapy plan design for solitary pulmonary tumors (SPTs) in radiotherapy. METHODS: The enrolled patients underwent CT simulation with three-dimensional (3D) CT non gating, prospective respiratory gating, and retrospective respiratory gating simulation. The target volumes were delineated on three sets of CT images, and radiotherapy plans were prepared accordingly. Tumor displacements and movement information obtained using the two respiratory gating approaches, as well as the target volumes and dosimetry parameters in the radiotherapy plan were compared. RESULTS: No significant difference was observed in tumor displacement measured using the two gating methods (p > 0.05). However, the internal gross tumor volumes (IGTVs), internal target volumes (ITVs), and planning target volumes (PTVs) based on the retrospective respiratory gating simulation were larger than those obtained using prospective gating (group A: pIGTV = 0.041, pITV = 0.003, pPTV = 0.008; group B: pIGTV = 0.025, pITV = 0.039, pPTV = 0.004). The two-gating PTVs were both smaller than those delineated on 3D non gating images (p < 0.001). V5Gy, V10Gy, V20Gy, V30Gy, and mean lung dose in the two gated radiotherapy plans were lower than those in the 3D non gating plan (p < 0.001); however, no significant difference was observed between the two gating plans (p > 0.05). CONCLUSIONS: The application of respiratory gating could reduce the target volume and the radiation dose that the normal lung tissue received. Compared to prospective respiratory gating, the retrospective gating provides more information about tumor movement in PTV.


Asunto(s)
Neoplasias Pulmonares , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Masculino , Femenino , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Dosificación Radioterapéutica , Carga Tumoral , Adulto , Estudios Retrospectivos , Nódulo Pulmonar Solitario/radioterapia , Nódulo Pulmonar Solitario/diagnóstico por imagen , Estudios Prospectivos , Respiración
15.
J Radiat Res ; 65(3): 337-349, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38718391

RESUMEN

Lymphocytes, which are highly sensitive to radiation, play a crucial role in the body's defense against tumors. Radiation-induced lymphopenia has been associated with poorer outcomes in different cancer types. Despite being the largest secondary lymphoid organ, the spleen has not been officially designated as an organ at risk. This study hypothesizes a connection between spleen irradiation and lymphopenia and seeks to establish evidence-based dosage limits for the spleen. We retrospectively analyzed data from 96 patients with locally advanced gastric cancer who received postoperative chemoradiotherapy (CRT) between May 2010 and May 2017. Complete blood counts were collected before, during and after CRT. We established a model for predicting the minimum absolute lymphocyte count (Min ALC) and to investigate potential associations between spleen dosimetric variables and Min ALC. The median follow-up was 60 months. The 5-year overall survival (OS) and disease-free survival (DFS) were 65.2% and 56.8%, respectively. The median values of pre-treatment ALC, Min ALC and post-treatment ALC were 1.40 × 109, 0.23 × 109 and 0.28 × 109/L, respectively. Regression analysis confirmed that the primary tumor location, number of fractions and spleen V5 were significant predictors of Min ALC during radiation therapy. Changes in ALC (ΔALC) were identified as an independent predictor of both OS and DFS. Spleen V5 is an independent predictor for Min ALC, and the maximum dose of the spleen is associated with an increased risk of severe lymphopenia. Therefore, these doses should be restricted in clinical practice. Additionally, ΔALC can serve as a prognostic indicator for adjuvant radiotherapy in gastric cancer.


Asunto(s)
Linfopenia , Bazo , Neoplasias Gástricas , Humanos , Linfopenia/etiología , Masculino , Femenino , Persona de Mediana Edad , Bazo/efectos de la radiación , Bazo/patología , Anciano , Neoplasias Gástricas/radioterapia , Neoplasias Gástricas/patología , Adulto , Relación Dosis-Respuesta en la Radiación , Recuento de Linfocitos , Supervivencia sin Enfermedad , Estudios Retrospectivos , Quimioradioterapia , Dosificación Radioterapéutica , Anciano de 80 o más Años
16.
J Radiat Res ; 65(3): 393-401, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38739893

RESUMEN

Hyaluronate gel injection (HGI) in the rectovaginal septum and vesicovaginal septum is effective in the setting of high-dose-rate image-guided adaptive brachytherapy (IGABT) for cervical cancer. We aimed to retrospectively investigate optimal conditions for HGI to achieve optimal dose distribution with a minimum number of HGI. We classified 50 IGABT plans of 13 patients with cervical cancer who received IGABT both with and without HGI in the rectovaginal septum and vesicovaginal septum into the following two groups: plan with (number of plans = 32) and plan without (number of plans = 18) HGI. The irradiation dose parameters of high-risk clinical target volume (CTVHR) and organs at risk per fraction were compared between these groups. We also developed the adjusted dose score (ADS), reflecting the overall irradiation dose status for four organs at risk and CTVHR in one IGABT plan and investigated its utility in determining the application of HGI. HGI reduced the maximum dose to the most exposed 2.0 cm3 (D2.0 cm3) of the bladder while increasing the minimum dose covering 90% of CTVHR and the percentage of CTVHR receiving 100% of the prescription dose in one IGABT plan without causing any associated complications. An ADS of ≥2.60 was the optimum cut-off value to decide whether to perform HGI. In conclusion, HGI is a useful procedure for improving target dose distribution while reducing D2.0 cm3 in the bladder in a single IGABT plan. The ADS can serve as a useful indicator for the implementation of HGI.


Asunto(s)
Braquiterapia , Geles , Ácido Hialurónico , Dosificación Radioterapéutica , Neoplasias del Cuello Uterino , Humanos , Femenino , Ácido Hialurónico/administración & dosificación , Braquiterapia/métodos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Radioterapia Guiada por Imagen/métodos , Inyecciones , Adulto , Órganos en Riesgo/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Factores de Tiempo , Estudios Retrospectivos
17.
Technol Cancer Res Treat ; 23: 15330338241256814, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38773777

RESUMEN

Objective: This prospective study aims to evaluate acute irradiation-induced xerostomia during radiotherapy by utilizing the normalized iodine concentration (NIC) derived from energy spectrum computed tomography (CT) iodine maps. Methods: In this prospective study, we evaluated 28 patients diagnosed with nasopharyngeal carcinoma. At 4 distinct stages of radiotherapy (0, 10, 20, and 30 fractions), each patient underwent CT scans to generate iodine maps. The NIC of both the left and right parotid glands was obtained, with the NIC at the 0-fraction stage serving as the baseline measurement. After statistically comparing the NIC obtained in the arterial phase, early venous phase, late venous phase, and delayed phase, we chose the late venous iodine concentration as the NIC and proceeded to analyze the variations in NIC at each radiotherapy interval. Using the series of NIC values, we conducted hypothesis tests to evaluate the extent of change in NIC within the parotid gland across different stages. Furthermore, we identified the specific time point at which the NIC decay exhibited the most statistically significant results. In addition, we evaluated the xerostomia grades of the patients at these 4 stages, following the radiation therapy oncology group (RTOG) xerostomia evaluation standard, to draw comparisons with the changes observed in NIC. Results: The NIC in the late venous phase exhibited the highest level of statistical significance (P < .001). There was a noticeable attenuation in NIC as the RTOG dry mouth grade increased. Particularly, at the 20 fraction, the NIC experienced the most substantial attenuation (P < .001), a significant negative correlation was observed between the NIC of the left, right, and both parotid glands, and the RTOG evaluation grade of acute irradiation-induced xerostomia (P < .001, r = -0.46; P < .001, r = -0.45; P < .001, r = -0.47). The critical NIC values for the left, right, and both parotid glands when acute xerostomia occurred were 0.175, 0.185, and 0.345 mg/ml, respectively, with AUC = 0.73, AUC = 0.75, and AUC = 0.75. Conclusion: The NIC may be used to evaluate changes in parotid gland function during radiotherapy and acute irradiation-induced xerostomia.


Asunto(s)
Yodo , Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Glándula Parótida , Tomografía Computarizada por Rayos X , Xerostomía , Humanos , Xerostomía/etiología , Masculino , Glándula Parótida/efectos de la radiación , Femenino , Carcinoma Nasofaríngeo/radioterapia , Persona de Mediana Edad , Adulto , Anciano , Neoplasias Nasofaríngeas/radioterapia , Estudios Prospectivos , Traumatismos por Radiación/etiología , Traumatismos por Radiación/diagnóstico , Dosificación Radioterapéutica
18.
Sci Rep ; 14(1): 10637, 2024 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724569

RESUMEN

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Asunto(s)
Radiometría , Radiometría/instrumentación , Radiometría/métodos , Humanos , Radioterapia/métodos , Radioterapia/normas , Radioterapia/instrumentación , Garantía de la Calidad de Atención de Salud , Electrones , Dosificación Radioterapéutica , Neoplasias/radioterapia , Diseño de Equipo , Terapia de Protones/instrumentación , Terapia de Protones/métodos
19.
Technol Cancer Res Treat ; 23: 15330338241257422, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38780512

RESUMEN

Purpose: To evaluate the dosimetric effects of intrafraction baseline shifts combined with rotational errors on Four-dimensional computed tomography-guided stereotactic body radiotherapy for multiple liver metastases (MLMs). Methods: A total of 10 patients with MLM (2 or 3 lesions) were selected for this retrospective study. Baseline shift errors of 0.5, 1.0, and 2.0 mm; and rotational errors of 0.5°, 1°, and 1.5°, were simulated about all axes. All of the baseline shifts and rotation errors were simulated around the planned isocenter using a matrix transformation of 6° of freedom. The coverage degradation of baseline shifts and rotational errors were analyzed according to the dose to 95% of the planning target volume (D95) and the volume covered by 95% of the prescribed dose (V95), and related changes in gross tumor volume were also analyzed. Results: At the rotation error of 0.5° and the baseline offset of less than 0.5 mm, the D95 and V95 values of all targets were >95%. For rotational errors of 1.0° (combined with all baseline shift errors), 36.3% of targets had D95 and V95 values of <95%. Coverage worsened substantially when the baseline shift errors were increased to 1.0 mm. D95 and V95 values were >95% for about 77.3% of the targets. Only 11.4% of the D95 and V95 values were >95% when the baseline shift errors were increased to 2.0 mm. When the rotational error was increased to 1.5° and baseline shift errors increased to 1.0 mm, the D95 and V95 values were >95% in only 3 cases. Conclusions: The multivariate regression model analysis in this study showed that the coverage of the target decreased further with reduced target volume, increasing the baseline drift, the rotation error, and the distance to the target.


Asunto(s)
Neoplasias Hepáticas , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Masculino , Estudios Retrospectivos , Femenino , Anciano , Persona de Mediana Edad , Carga Tumoral , Radiometría , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada Cuatridimensional
20.
Radiat Oncol ; 19(1): 54, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702761

RESUMEN

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment alternative for patients with localized low and intermediate risk prostate cancer patients. As already explored by some authors in the context of conventional moderate hypofractionated radiotherapy, focal boost of the index lesion defined by magnetic resonance imaging (MRI) is associated with an improved biochemical outcome. The objective of this phase II trial is to determine the effectiveness (in terms of biochemical, morphological and functional control), the safety and impact on quality of life, of prostate SABR with MRI guided focal dose intensification in males with intermediate and high-risk localized prostate cancer. METHODS: Patients with intermediate and high-risk prostate cancer according to NCCN definition will be treated with SABR 36.25 Gy in 5 fractions to the whole prostate gland with MRI guided simultaneous integrated focal boost (SIB) to the index lesion (IL) up to 50 Gy in 5 fractions, using a protocol of bladder trigone and urethra sparing. Intra-fractional motion will be monitored with daily cone beam computed tomography (CBCT) and intra-fractional tracking with intraprostatic gold fiducials. Androgen deprivation therapy (ADT) will be allowed. The primary endpoint will be efficacy in terms of biochemical and local control assessed by Phoenix criteria and post-treatment MRI respectively. The secondary endpoints will encompass acute and late toxicity, quality of life (QoL) and progression-free survival. Finally, the subgroup of high-risk patients will be involved in a prospective study focused on immuno-phenotyping. DISCUSSION: To the best of our knowledge, this is the first trial to evaluate the impact of post-treatment MRI on local control among patients with intermediate and high-risk prostate cancer undergoing SABR and MRI guided focal intensification. The results of this trial will enhance our understanding of treatment focal intensification through the employment of the SABR technique within this specific patient subgroup, particularly among those with high-risk disease, and will help to clarify the significance of MRI in monitoring local responses. Hopefully will also help to design more personalized biomarker-based phase III trials in this specific context. Additionally, this trial is expected to be incorporated into a prospective radiomics study focused on localized prostate cancer treated with radiotherapy. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL SPONSOR: IRAD/SEOR (Instituto de Investigación de Oncología Radioterápica / Sociedad Española de Oncología Radioterápica). STUDY SETTING: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL STATUS: Protocol version number and date: v. 5/ 17 May-2023. Date of recruitment start: August 8, 2023. Date of recruitment completion: July 1, 2024.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Guiada por Imagen , Anciano , Humanos , Masculino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Estudios Prospectivos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Calidad de Vida , Radiocirugia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Vejiga Urinaria/efectos de la radiación , Ensayos Clínicos Fase II como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA