Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.617
Filtrar
1.
Int J Mol Sci ; 25(15)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39125977

RESUMEN

This study aimed to synthesize a novel elastomeric ligature with dimethylaminohexadecyl methacrylate (DMAHDM) grafted, providing a new strategy for improving the issue of enamel demineralization during fixed orthodontics. DMAHDM was incorporated into elastomeric ligatures at different mass fractions using ultraviolet photochemical grafting. The antibacterial properties were evaluated and the optimal DMAHDM amount was determined based on cytotoxicity assays. Moreover, tests were conducted to evaluate the in vivo changes in the mechanical properties of the elastomeric ligatures. To assess the actual in vivo effectiveness in preventing enamel demineralization, a rat demineralization model was established, with analyses focusing on changes in surface microstructure, elemental composition, and nanomechanical properties. Elastomeric ligatures with 2% DMAHDM showed excellent biocompatibility and the best antibacterial properties, reducing lactic acid production by 65.3% and biofilm bacteria by 50.0% within 24 h, without significant mechanical property differences from the control group (p > 0.05). Most importantly, they effectively prevented enamel demineralization in vivo, enhancing elastic modulus by 73.2% and hardness by 204.8%. Elastomeric ligatures incorporating DMAHDM have shown great potential for application in preventing enamel demineralization, providing a new strategy to solve this issue during fixed orthodontics.


Asunto(s)
Esmalte Dental , Elastómeros , Desmineralización Dental , Desmineralización Dental/prevención & control , Animales , Elastómeros/química , Ratas , Esmalte Dental/efectos de los fármacos , Antibacterianos/farmacología , Antibacterianos/química , Metacrilatos/química , Metacrilatos/farmacología , Aparatos Ortodóncicos , Biopelículas/efectos de los fármacos , Masculino
3.
Int J Biol Macromol ; 275(Pt 1): 133621, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38960248

RESUMEN

Plant fiber-reinforced polylactic acid (PLA) composites are extensively utilized in eco-friendly packaging, sports equipment, and various other applications due to their environmental benefits and cost-effectiveness. However, PLA suffers from brittleness and poor toughness, which restricts its use in scenarios demanding high toughness. To expand the application range of plant fiber-reinforced PLA-based composites and enhance their poor toughness, this study employed a two-step process involving wheat straw fiber (WF) to improve the interfacial compatibility between WF and PLA. Additionally, four elastomeric materials-poly (butylene adipate-co-terephthalate) (PBAT), poly (butylene succinate) (PBS), polycaprolactone (PCL), and polyhydroxyalkanoate (PHA)-were incorporated to achieve a mutual reactive interface enhancement and elastomeric toughening. The results demonstrated that Fe3+/TsWF/PLA/PBS exhibited a tensile strength, elongation at break, and impact strength of 34.01 MPa, 14.23 %, and 16.2 kJ/m2, respectively. These values represented a 2.4 %, 86.7 %, and 119 % increase compared to the unmodified composites. Scanning electron microscopy analysis revealed no fiber exposure in the cross-section, indicating excellent interfacial compatibility. Furthermore, X-ray diffraction and differential scanning calorimetry tests confirmed improvements in the crystalline properties of the composites. This work introduces a novel approach for preparing fiber-reinforced PLA-based composites with exceptional toughness and strength.


Asunto(s)
Elastómeros , Poliésteres , Resistencia a la Tracción , Poliésteres/química , Elastómeros/química , Polímeros/química , Triticum/química , Ensayo de Materiales , Butileno Glicoles/química
4.
Biomacromolecules ; 25(8): 5019-5027, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-38982931

RESUMEN

Dielectric elastomers generate muscle-like electroactive actuation, which is applicable in soft machines, medical devices, etc. However, the actuation strain and energy density of most dielectric elastomers, in the absence of prestretch, have long been limited to ∼20% and ∼10 kJ m-3, respectively. Here, we report a dielectric elastomer with ZrO2 nanoparticles confined in nanodomains, which achieves an actuation strain >100% and an energy density of ∼150 kJ m-3 without prestretch. We decorate the surface of each nanoparticle with a layer of a diblock oligomer, poly(acrylic acid-b-styrene). The surface-decorated nanoparticles coassemble with a triblock copolymer elastomer, poly(styrene-b-(2-ethylhexyl acrylate)-b-styrene) during cosolvent casting. Consequently, the nanoparticles are confined in the polystyrene nanodomains, which results in a dielectric elastomer nanocomposite with a low modulus, high breakdown strength, and intense strain-hardening behavior. During the actuation, the nanocomposite avoids the snap-through instability that most elastomers would suffer and achieves a superior actuation performance.


Asunto(s)
Elastómeros , Poliestirenos , Circonio , Elastómeros/química , Circonio/química , Poliestirenos/química , Nanocompuestos/química , Nanopartículas/química , Órganos Artificiales , Resinas Acrílicas/química
5.
Int J Mol Sci ; 25(13)2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-39000090

RESUMEN

The acidic byproducts of bacteria in plaque around orthodontic brackets contribute to white spot lesion (WSL) formation. Nitric oxide (NO) has antibacterial properties, hindering biofilm formation and inhibiting the growth of oral microbes. Materials that mimic NO release could prevent oral bacteria-related pathologies. This study aims to integrate S-nitroso-acetylpenicillamine (SNAP), a promising NO donor, into orthodontic elastomeric ligatures, apply an additional polymer coating, and evaluate the NO-release kinetics and antimicrobial activity against Streptococus mutans. SNAP was added to clear elastomeric chains (8 loops, 23 mm long) at three concentrations (50, 75, 100 mg/mL, and a control). Chains were then coated, via electrospinning, with additional polymer (Elastollan®) to aid in extending the NO release. NO flux was measured daily for 30 days. Samples with 75 mg/mL SNAP + Elastollan® were tested against S. mutans for inhibition of biofilm formation on and around the chain. SNAP was successfully integrated into ligatures at each concentration. Only the 75 mg/mL SNAP chains maintained their elasticity. After polymer coating, samples exhibited a significant burst of NO on the first day, exceeding the machine's reading capacity, which gradually decreased over 29 days. Ligatures also inhibited S. mutans growth and biofilm formation. Future research will assess their mechanical properties and cytotoxicity. This study presents a novel strategy to address white spot lesion (WSL) formation and bacterial-related pathologies by utilizing nitric oxide-releasing materials. Manufactured chains with antimicrobial properties provide a promising solution for orthodontic challenges, showing significant potential for academic-industrial collaboration and commercial viability.


Asunto(s)
Biopelículas , Elastómeros , Óxido Nítrico , Streptococcus mutans , Streptococcus mutans/efectos de los fármacos , Streptococcus mutans/crecimiento & desarrollo , Elastómeros/química , Óxido Nítrico/química , Óxido Nítrico/metabolismo , Biopelículas/efectos de los fármacos , S-Nitroso-N-Acetilpenicilamina/farmacología , S-Nitroso-N-Acetilpenicilamina/química , Antibacterianos/farmacología , Antibacterianos/química , Antibacterianos/síntesis química , Soportes Ortodóncicos/microbiología , Pruebas de Sensibilidad Microbiana , Antiinfecciosos/farmacología , Antiinfecciosos/química , Antiinfecciosos/síntesis química , Donantes de Óxido Nítrico/farmacología , Donantes de Óxido Nítrico/química , Donantes de Óxido Nítrico/síntesis química , Humanos
6.
BMC Oral Health ; 24(1): 713, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902666

RESUMEN

BACKGROUND: Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs without detrimentally affecting their physical properties and biocompatibility. This study compared the chemical and mechanical properties, as well as the cytotoxicity, of elastomeric micelles-containing glass ionomer cement (DeltaFil, DT) with commonly used materials, including EQUIA Forte Fil (EF), Fuji IX GP Extra (F9), and Ketac Molar (KT). METHOD: Powder particles of GICs were examined with SEM-EDX. Setting kinetics were assessed using ATR-FTIR. Biaxial flexural strength/modulus and Vickers surface microhardness were measured after immersion in water for 24 h and 4 weeks. The release of F, Al, Sr, and P in water over 8 weeks was analyzed using a fluoride-specific electrode and ICP-OES. The toxicity of the material extract on mouse fibroblasts was also evaluated. RESULTS: High fluoride levels in the powder were detected with EF and F9. DT demonstrated an initial delay followed by a faster acid reaction compared to other cements, suggesting an improved snap set. DT also exhibited superior flexural strength than other materials at both 24 h and 4 weeks but lower surface microhardness (p < 0.05). EF and F9 showed higher release of F, Al, and P than DT and KT. There was no statistically significant difference in fibroblast viability among the tested materials (p > 0.05). CONCLUSIONS: Elastomeric micelles-containing glass ionomer cement (DT) exhibited satisfactory mechanical properties and cytocompatibility compared with other materials. DT could, therefore, potentially be considered an alternative high-strength GIC for load-bearing restorations.


Asunto(s)
Elastómeros , Fibroblastos , Resistencia Flexional , Cementos de Ionómero Vítreo , Dureza , Ensayo de Materiales , Micelas , Cementos de Ionómero Vítreo/toxicidad , Cementos de Ionómero Vítreo/química , Animales , Ratones , Fibroblastos/efectos de los fármacos , Elastómeros/química , Elastómeros/toxicidad , Aluminio/química , Fluoruros/química , Estroncio/química , Cemento de Policarboxilato/química , Cemento de Policarboxilato/toxicidad , Supervivencia Celular/efectos de los fármacos , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Docilidad , Cinética , Espectroscopía Infrarroja por Transformada de Fourier , Estrés Mecánico , Factores de Tiempo , Materiales Biocompatibles/química
7.
Sensors (Basel) ; 24(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38931570

RESUMEN

Conventional passive ankle foot orthoses (AFOs) have not seen substantial advances or functional improvements for decades, failing to meet the demands of many stakeholders, especially the pediatric population with neurological disorders. Our objective is to develop the first comfortable and unobtrusive powered AFO for children with cerebral palsy (CP), the DE-AFO. CP is the most diagnosed neuromotor disorder in the pediatric population. The standard of care for ankle control dysfunction associated with CP, however, is an unmechanized, bulky, and uncomfortable L-shaped conventional AFO. These passive orthoses constrain the ankle's motion and often cause muscle disuse atrophy, skin damage, and adverse neural adaptations. While powered orthoses could enhance natural ankle motion, their reliance on bulky, noisy, and rigid actuators like DC motors limits their acceptability. Our innovation, the DE-AFO, emerged from insights gathered during customer discovery interviews with 185 stakeholders within the AFO ecosystem as part of the NSF I-Corps program. The DE-AFO is a biomimetic robot that employs artificial muscles made from an electro-active polymer called dielectric elastomers (DEs) to assist ankle movements in the sagittal planes. It incorporates a gait phase detection controller to synchronize the artificial muscles with natural gait cycles, mimicking the function of natural ankle muscles. This device is the first of its kind to utilize lightweight, compact, soft, and silent artificial muscles that contract longitudinally, addressing traditional actuated AFOs' limitations by enhancing the orthosis's natural feel, comfort, and acceptability. In this paper, we outline our design approach and describe the three main components of the DE-AFO: the artificial muscle technology, the finite state machine (the gait phase detection system), and its mechanical structure. To verify the feasibility of our design, we theoretically calculated if DE-AFO can provide the necessary ankle moment assistance for children with CP-aligning with moments observed in typically developing children. To this end, we calculated the ankle moment deficit in a child with CP when compared with the normative moment of seven typically developing children. Our results demonstrated that the DE-AFO can provide meaningful ankle moment assistance, providing up to 69% and 100% of the required assistive force during the pre-swing phase and swing period of gait, respectively.


Asunto(s)
Tobillo , Parálisis Cerebral , Ortesis del Pié , Robótica , Parálisis Cerebral/fisiopatología , Parálisis Cerebral/rehabilitación , Humanos , Niño , Robótica/métodos , Tobillo/fisiopatología , Tobillo/fisiología , Elastómeros/química , Marcha/fisiología , Diseño de Equipo , Fenómenos Biomecánicos
8.
Sci Robot ; 9(91): eadk3925, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38865475

RESUMEN

Electrotactile stimulus is a form of sensory substitution in which an electrical signal is perceived as a mechanical sensation. The electrotactile effect could, in principle, recapitulate a range of tactile experience by selective activation of nerve endings. However, the method has been plagued by inconsistency, galvanic reactions, pain and desensitization, and unwanted stimulation of nontactile nerves. Here, we describe how a soft conductive block copolymer, a stretchable layout, and concentric electrodes, along with psychophysical thresholding, can circumvent these shortcomings. These purpose-designed materials, device layouts, and calibration techniques make it possible to generate accurate and reproducible sensations across a cohort of 10 human participants and to do so at ultralow currents (≥6 microamperes) without pain or desensitization. This material, form factor, and psychophysical approach could be useful for haptic devices and as a tool for activation of the peripheral nervous system.


Asunto(s)
Elastómeros , Conductividad Eléctrica , Psicofísica , Tacto , Humanos , Tacto/fisiología , Adulto , Femenino , Masculino , Diseño de Equipo , Estimulación Eléctrica , Adulto Joven , Polímeros , Electrodos , Calibración , Percepción del Tacto/fisiología
9.
Int J Biol Macromol ; 271(Pt 2): 132766, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38823742

RESUMEN

The efficient development and utilization of green biomass-based macromolecule engineering materials are essential for the sustainable development of human civilization. In this study, lignin-based ethylene-propylene-diene-monomer (EPDM) composites with excellent mechanical performance were fabricated using a simple method. The effects of water-insoluble enzymatically hydrolyzed lignin (EL) and alkali lignin (KL) on the mechanical performance of the composites were investigated separately. The results showed that the tensile strength of EPDM reinforced with KL and EL increased to 24.5 MPa and 22.1 MPa, respectively, surpassing that of the carbon black (CB)-reinforced EPDM. After 72 h of thermo-oxidative aging, the retention rates of the tensile strength and elongation at break in the lignin-reinforced EPDM were much better than those formed with pure CB, indicating that lignin significantly improved the thermo-oxidative aging resistance of the composites. In summary, the Zn2+ coordination bonds formed between the interface of EPDM and lignin in lignin/CB/EPDM ternary composites effectively improved the mechanical performance and aging resistance of the composites. This study has significant implications for enhancing the utilization of lignin and green functional polymer materials.


Asunto(s)
Lignina , Lignina/química , Resistencia a la Tracción , Etilenos/química , Relación Estructura-Actividad , Zinc/química , Oxidación-Reducción , Reactivos de Enlaces Cruzados/química , Elastómeros
10.
Prog Orthod ; 25(1): 24, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880839

RESUMEN

INTRODUCTION: Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health. AIM: This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances. METHODS: Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach. RESULTS: A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias. CONCLUSIONS: Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load. REGISTRATION: PROSPERO (CRD42023444383).


Asunto(s)
Elastómeros , Aparatos Ortodóncicos Fijos , Humanos , Acero , Índice Periodontal , Soportes Ortodóncicos , Ligadura
11.
Mater Horiz ; 11(16): 3911-3920, 2024 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-38836844

RESUMEN

Expanding the detection information of wearable smart devices in applications has practical implications for their use in daily life and healthcare. Damage and breakage caused by mechanical injuries and continuous use are unavoidable for polymer matrices so self-healing properties are expected to be conferred on flexible sensors to extend their life and durability. In addition, a good linearity of relative resistance change vs. strain (gauge factor, GF) facilitates the streamlined conversion of electrical signals to 3D information of human motion, whereas existing works on sensors neglect the quantitative analysis of signals. This letter reports a self-healable flexible electronic sensor based on hydrogen bonding and electrostatic interaction between maleic acid-grafted natural rubber (MNR), polyaniline (PANI), and phytic acid (PA). MNR is the flexible matrix and the template for aniline (ANI) polymerization, and PA acts as the dopant and crosslinking agent. The MNR-PANI-PA sensor shows easy self-healing at room temperature, enhanced mechanical behaviour (∼2.5 MPa, 1000% strain), and excellent linearity (GF of 13.8 over 250% strain and GF of 32.0 over 250-100% strain). Due to the highly linear relationship between ΔR/R and bending angle, the electrical signals of human limb movement can output relevant information on bending angle and frequency. By constructing a sensing array, changes in the position and magnitude of applied pressure could also be detected in real-time. Based on these advantages, the MNR-PANI-PA composite sensor is expected to have potential applications in health monitoring, body motion detection, and electronic skins.


Asunto(s)
Compuestos de Anilina , Elastómeros , Movimiento , Dispositivos Electrónicos Vestibles , Humanos , Elastómeros/química , Movimiento/fisiología , Conductividad Eléctrica , Presión , Ácido Fítico/química , Goma/química , Maleatos/química
12.
Drug Discov Ther ; 18(3): 188-193, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38880603

RESUMEN

Wheelchair cushions are recommended to be used with wheelchair and can protect the buttocks from pain and injury by relieving interface pressure for wheelchair users. However, further investigations are required for proper use in response to the development of new types of wheelchair cushions. The objective of this study was to evaluate physical characteristics of wheelchair cushions by comparing pressure redistributing effects of four types of cushions. The participants were 16 healthy adults who consented to participate in this study. A pressure mapping system (CONFORMat, Nitta Corp.) was used for the measurements. Pressure at ischium was measured immediately after the stabilization of the sitting posture and 10 minutes after. The pressure at ischium significantly decreased with any wheelchair cushions (P < 0.01). A significant negative correlation between body mass index and pressure at ischium was observed without a wheelchair cushion (r = - 0.70), however, the correlation disappeared upon use of a wheelchair cushion. The pressure at ischium increased over time with cushions of urethane, air, and urethane-air hybrid while that with the 3D thermoplastic elastomer cushion did not, and the change in the pressure was statistically less than that in other cushions (P < 0.01). Use of wheelchair cushions was effective in redistribution of the pressure at ischium, and the overtime change in the pressure depends on the type of used cushions.


Asunto(s)
Elastómeros , Diseño de Equipo , Isquion , Presión , Silla de Ruedas , Humanos , Adulto , Elastómeros/química , Masculino , Femenino , Uretano/química , Adulto Joven , Índice de Masa Corporal , Úlcera por Presión/prevención & control
13.
ACS Appl Mater Interfaces ; 16(19): 25404-25414, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38692284

RESUMEN

Liquid crystal elastomers (LCEs), as a classical two-way shape-memory material, are good candidates for developing artificial muscles that mimic the contraction, expansion, or rotational behavior of natural muscles. However, biomimicry is currently focused more on the actuation functions of natural muscles dominated by muscle fibers, whereas the tactile sensing functions that are dominated by neuronal receptors and synapses have not been well captured. Very few studies have reported the sensing concept for LCEs, but the signals were still donated by macroscopic actuation, that is, variations in angle or length. Herein, we develop a conductive porous LCE (CPLCE) using a solvent (dimethyl sulfoxide (DMSO))-templated photo-cross-linking strategy, followed by carbon nanotube (CNT) incorporation. The CPLCE has excellent reversible contraction/elongation behavior in a manner similar to the actuation functions of skeletal muscles. Moreover, the CPLCE shows excellent pressure-sensing performance by providing real-time electrical signals and is capable of microtouch sensing, which is very similar to natural tactile sensing. Furthermore, macroscopic actuation and tactile sensation can be integrated into a single system. Proof-of-concept studies reveal that the CPLCE-based artificial muscle is sensitive to external touch while maintaining its excellent actuation performance. The CPLCE with tactile sensation beyond reversible actuation is expected to benefit the development of versatile artificial muscles and intelligent robots.


Asunto(s)
Elastómeros , Cristales Líquidos , Nanotubos de Carbono , Cristales Líquidos/química , Elastómeros/química , Nanotubos de Carbono/química , Porosidad , Solventes/química , Tacto/fisiología , Órganos Artificiales , Músculo Esquelético/fisiología , Músculo Esquelético/química , Humanos
14.
Int J Biol Macromol ; 268(Pt 2): 131946, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692545

RESUMEN

The development of flexible wearable multifunctional electronics has gained great attention in the field of human motion monitoring. However, developing mechanically tough, highly stretchable, and recyclable composite conductive materials for application in multifunctional sensors remained great challenges. In this work, a mechanically tough, highly stretchable, and recyclable composite conductive elastomer with the dynamic physical-chemical dual-crosslinking network was fabricated by the combination of multiple hydrogen bonds and dynamic ester bonds. To prepare the proposed composite elastomers, the polyaniline-modified carboxylate cellulose nanocrystals (C-CNC@PANI) were used as both conductive filler to yield high conductivity of 15.08 mS/m, and mechanical reinforcement to construct the dynamic dual-crosslinking network with epoxidized natural rubber latex to realize the high mechanical strength (8.65 MPa) and toughness (29.57 MJ/m3). Meanwhile, the construction of dynamic dual-crosslinking network endowed the elastomer with satisfactory recyclability. Based on these features, the composite conductive elastomers were used as strain sensors, and electrode material for assembling flexible and recyclable self-powered sensors for monitoring human motions. Importantly, the composite conductive elastomers maintained reliable sensing and energy harvesting performance even after multiple recycling process. This study provides a new strategy for the preparation of recyclable, mechanically tough composite conductive materials for wearable sensors.


Asunto(s)
Celulosa , Elastómeros , Conductividad Eléctrica , Goma , Dispositivos Electrónicos Vestibles , Elastómeros/química , Celulosa/química , Goma/química , Humanos , Nanocompuestos/química , Nanopartículas/química , Fenómenos Mecánicos , Compuestos de Anilina/química
15.
ACS Appl Bio Mater ; 7(6): 3777-3785, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38754861

RESUMEN

Oral devices, such as foil-type devices, show great potential for the delivery of poorly permeable macromolecules by enabling unidirectional release of the loaded pharmaceutical composition in close proximity to the epithelium in the small intestine or colon. However, one of the primary concerns associated with the use of foil-type devices so far has been the utilization of nonbiodegradable elastomers in the fabrication of the devices. Therefore, research into biodegradable substitute materials with similar characteristics enables drug delivery in a sustainable and environmentally friendly manner. In this study, a biodegradable elastomer, polyoctanediol citrate (POC), was synthesized via a one-pot reaction, with subsequent purification and microscale pattern replication via casting. The microstructure geometry was designed to enable fabrication of foil-type devices with the selected elastomer, which has a high intrinsic surface free energy. The final elastomer was demonstrated to have an elastic modulus ranging up to 2.2 ± 0.1 MPa, with strain at failure up to 110.1 ± 1.5%. Devices were loaded with acetaminophen and enterically coated, demonstrating 100% release at 2.5 h, following dissolution for 1 h in 0.1 M hydrochloric acid and 1.5 h in pH 6.8 phosphate-buffered saline. The elastomer demonstrated promising properties based on mechanical testing, surface free energy evaluation, and degradation studies.


Asunto(s)
Materiales Biocompatibles , Elastómeros , Ensayo de Materiales , Tamaño de la Partícula , Elastómeros/química , Materiales Biocompatibles/química , Materiales Biocompatibles/síntesis química , Sistemas de Liberación de Medicamentos , Humanos , Acetaminofén/química , Acetaminofén/administración & dosificación , Administración Oral , Citratos/química , Sustancias Macromoleculares/química , Sustancias Macromoleculares/síntesis química , Polímeros/química
16.
Biomaterials ; 309: 122598, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38696943

RESUMEN

Current vascular grafts, primarily Gore-Tex® and Dacron®, don't integrate with the host and have low patency in small-diameter vessels (<6 mm). Biomaterials that possess appropriate viscoelasticity, compliance, and high biocompatibility are essential for their application in small blood vessels. We have developed metal ion crosslinked poly(propanediol-co-(hydroxyphenyl methylene)amino-propanediol sebacate) (M-PAS), a biodegradable elastomer with a wide range of mechanical properties. We call these materials metallo-elastomers. An initial test on Zn-, Fe-, and Cu-PAS grafts reveals that Cu-PAS is the most suitable because of its excellent elastic recoil and well-balanced polymer degradation/tissue regeneration rate. Here we report host remodeling of Cu-PAS vascular grafts in rats over one year. 76 % of the grafts remain patent and >90 % of the synthetic polymer is degraded by 12 months. Extensive cell infiltration leads to a positive host remodeling. The remodeled grafts feature a fully endothelialized lumen. Circumferentially organized smooth muscle cells, elastin fibers, and widespread mature collagen give the neoarteries mechanical properties similar to native arteries. Proteomic analysis further reveals the presence of important vascular proteins in the neoarteries. Evidence suggests that Cu-PAS is a promising material for engineering small blood vessels.


Asunto(s)
Prótesis Vascular , Arterias Carótidas , Elastómeros , Animales , Elastómeros/química , Ratas , Masculino , Materiales Biocompatibles/química , Ratas Sprague-Dawley , Polímeros/química , Ensayo de Materiales
17.
ACS Nano ; 18(22): 14558-14568, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38761154

RESUMEN

To propel electronic skin (e-skin) to the next level by integrating artificial intelligence features with advanced sensory capabilities, it is imperative to develop stretchable memory device technology. A stretchable memory device for e-skin must offer, in particular, long-term data storage while ensuring the security of personal information under any type of deformation. However, despite the significance of these needs, technology related to stretchable memory devices remains in its infancy. Here, we report an intrinsically stretchable floating gate (FG) polymer memory transistor. The device features a dual-stimuli (optical and electrical) writing system to prevent easy erasure of recorded data. An FG comprising an intermixture of Ag nanoparticles and elastomer and with proper energy-band alignment between the semiconductor and dielectric facilitated sustainable memory performance, while achieving a high memory on/off ratio (>105) and a long retention time (106 s) with the ability to withstand 50% uniaxial or 30% biaxial strain. In addition, our memory transistor exhibited high mechanical durability over multiple stretching cycles (1000 times), along with excellent environmental stability with respect to factors such as temperature, moisture, air, and delamination. Finally, we fabricated a 7 × 7 active-matrix memory transistor array for personalized storage of e-skin data and successfully demonstrated its functionality.


Asunto(s)
Transistores Electrónicos , Dispositivos Electrónicos Vestibles , Almacenamiento y Recuperación de la Información , Plata/química , Humanos , Elastómeros/química , Equipos de Almacenamiento de Computador , Nanopartículas del Metal/química , Diseño de Equipo
18.
Macromol Rapid Commun ; 45(13): e2400022, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38704741

RESUMEN

The preparation of self-healing polyurethane elastomers (PUEs) incorporating dynamic bonds is of considerable practical significance. However, developing a PUE with outstanding mechanical properties and high self-healing efficiency poses a significant challenge. Herein, this work has successfully developed a series of self-healing PUEs with various outstanding properties through rational molecular design. These PUEs incorporate m-xylylene diisocyanate and reversible dimethylglyoxime as hard segment, along with polytetramethylene ether glycol as soft segment. A significant amount of dynamic oxime-carbamate and hydrogen bonds are formed in hard segment. The microphase separated structure of the PUEs enables them to be colorless with a transparency of >90%. Owing to the chemical composition and multiple dynamic interactions, the PUEs are endowed with ultra-high tensile strength of 34.5 MPa, satisfactory toughness of 53.9 MJ m-3, and great elastic recovery both at low and high strains. The movement of polymer molecular chains and the dynamic reversible interactions render a self-healing efficiency of 101% at 70 °C. In addition, this self-healing polyurethane could still maintain high mechanical properties after recycling. This study provides a design strategy for the preparation of a comprehensive polyurethane with superior overall performance, which holds wide application prospects in the fields of flexible displays and solar cells.


Asunto(s)
Carbamatos , Elastómeros , Enlace de Hidrógeno , Oximas , Poliuretanos , Resistencia a la Tracción , Poliuretanos/química , Oximas/química , Elastómeros/química , Carbamatos/química , Estructura Molecular , Elasticidad
19.
Adv Mater ; 36(32): e2400241, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38780175

RESUMEN

Biological organisms exhibit phenomenal adaptation through morphology-shifting mechanisms including self-amputation, regeneration, and collective behavior. For example, reptiles, crustaceans, and insects amputate their own appendages in response to threats. Temporary fusion between individuals enables collective behaviors, such as in ants that temporarily fuse to build bridges. The concept of morphological editing often involves the addition and subtraction of mass and can be linked to modular robotics, wherein synthetic body morphology may be revised by rearranging parts. This work describes a reversible cohesive interface made of thermoplastic elastomer that allows for strong attachment and easy detachment of distributed soft robot modules without direct human handling. The reversible joint boasts a modulus similar to materials commonly used in soft robotics, and can thus be distributed throughout soft robot bodies without introducing mechanical incongruities. To demonstrate utility, the reversible joint is implemented in two embodiments: a soft quadruped robot that self-amputates a limb when stuck, and a cluster of three soft-crawling robots that fuse to cross a land gap. This work points toward future robots capable of radical shape-shifting via changes in mass through autotomy and interfusion, as well as highlights the crucial role that interfacial stiffness change plays in autotomizable biological and artificial systems.


Asunto(s)
Elastómeros , Robótica , Elastómeros/química , Animales
20.
J Mech Behav Biomed Mater ; 155: 106566, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38729087

RESUMEN

The objective of this study is to develop a reliable tribological model to enable a more thorough investigation of the frictional behavior of fascia tissues connected to non-specific lower back pain. Several models were designed and evaluated based on their coefficient of friction, using a low-frequency, low-load reciprocating motion. The study found that two technical elastomers, layered on PDMS to simulate the fascia and underlying muscle, are suitable substitutes for biological tissue in the model. The influence of tribopair geometry was also examined, and the results showed that greater conformity of contact leads to a lower COF, regardless of the material combination used. Finally, the friction properties of HA of various molecular weights and concentrations were tested.


Asunto(s)
Fascia , Fricción , Ensayo de Materiales , Fascia/fisiología , Dimetilpolisiloxanos/química , Fenómenos Biomecánicos , Modelos Biológicos , Elastómeros/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA