Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Lab Anim ; 55(2): 177-180, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33045909

RESUMEN

Pigs are used to model humans in gastrointestinal (GI) studies because of their comparable size, physiology and behaviour: both are monogastric omnivores. A porcine surgical model for testing novel, tethered ultrasound capsule endoscopes (USCE) requires a clean, motile small intestine. Recommendations for human GI tract preparation before the mechanically similar process of video capsule endoscopy describe using oral purgatives, while high-carbohydrate drinks are recommended before colorectal surgery. Reports of the GI preparation of pigs exist but lack technical details, that is, administration, efficacy and side effects. This report details feeding a high-energy liquid diet to 11 female pigs undergoing surgery and USCE which was readily accepted and easily administered, and which produced a clean, motile small intestine and caused no detectable physiological/behavioural abnormalities.


Asunto(s)
Crianza de Animales Domésticos/métodos , Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía Capsular/estadística & datos numéricos , Dieta , Sus scrofa/fisiología , Animales , Femenino , Intestino Delgado/fisiología , Modelos Animales , Sus scrofa/cirugía
2.
Inflamm Bowel Dis ; 24(11): 2339-2347, 2018 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-29718225

RESUMEN

The patency capsule is a radiopaque, dissolvable diagnostic tool, similar in shape and size to small bowel capsule endoscopes. It was developed to offer a simple, safe, efficient, and accurate evaluation of small bowel functional patency. Although unable to provide direct visual information regarding the presence and location of strictures, masses, or luminal narrowing of the small bowel, a successful patency test minimizes the risk of retention and allows the safe administration of a capsule endoscope. However, its use entails a low risk of potentially harmful adverse events, which in their majority are indolent and resolve spontaneously. Abdominal pain and symptomatic retention are accountable for the majority of reported adverse events, whereas a limited number of reports describe life-threatening complications, namely intestinal obstruction, perforation, and intestinal ischemia. Computed tomography is the modality of choice for the identification of the exact position of an impacted patency capsule, whilst the use of plain abdominal radiographs should be avoided for the evaluation of the patency capsule position, as they provide false information. Hereby, we present a comprehensive review of the available literature regarding the characteristics, indications, clinical use, effectiveness, and adverse events of the patency capsule.10.1093/ibd/izy152_video1izy152.video15777752348001.


Asunto(s)
Endoscopios en Cápsulas/estadística & datos numéricos , Constricción Patológica/diagnóstico , Humanos
3.
Int Forum Allergy Rhinol ; 5(12): 1136-40, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26228817

RESUMEN

BACKGROUND: High-resolution microendoscopy (HRME) enables real-time imaging of epithelial tissue. The utility of this novel imaging modality for inverted papilloma has not been previously described. This study examines the ability of otolaryngologists to differentiate between images of inverted papilloma and normal sinonasal mucosa obtained with a HRME. METHODS: Inverted papilloma and normal sinonasal mucosa specimens were stained with a contrast agent, proflavine. HRME images were subsequently captured. Histopathological diagnosis was obtained for each sample. Quality-controlled images were used to assemble a training set. After reviewing the training images, 6 otolaryngologists without prior HRME experience reviewed and classified test images. RESULTS: Five samples of inverted papilloma and 2 normal sinonasal mucosa samples were collected. Four representative images from each specimen were used for the 28-image test set. The mean accuracy among all reviewers was 89.9% (95% confidence interval [CI], 84.3% to 94.0%). The sensitivity to correctly identify inverted papilloma was 86.7% (95% CI, 79.2% to 92.2%), and the specificity was 92.9% (95% CI, 89.0% to 100.0%). The Fleiss kappa interrater reliability score was 0.80 (95% CI, 0.70 to 0.89). CONCLUSION: Inverted papilloma and normal sinonasal mucosa have distinct HRME imaging characteristics. Otolaryngologists can be successfully trained to distinguish between inverted papilloma and normal sinonasal mucosa. HRME is a feasible tool for identification of inverted papilloma. By conducting future in vivo trials, HRME potentially may enable real-time surgical margin determination during surgical excision of inverted papilloma.


Asunto(s)
Mucosa Nasal/patología , Neoplasias Nasales/diagnóstico , Papiloma Invertido/diagnóstico , Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía , Humanos , Neoplasias Nasales/patología , Variaciones Dependientes del Observador , Otolaringología , Papiloma Invertido/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Z Gastroenterol ; 51(8): 747-52, 2013 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-23955141

RESUMEN

BACKGROUND AND AIMS: Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices the US Food and Drug Administration and the manufacturers recommend not to use capsule endoscopy in these patients. METHODS: Studies investigating possible interference between small bowel capsule endoscopy and cardiac pacemakers and implanted cardioverters were analysed. For the review we considered studies published in English or German and indexed in PubMed (Medline) as well as relevant abstracts and technical data from the manufacturer. RESULTS: In vitro and in vivo studies applying real capsules revealed no clinically relevant interference with pacemakers and implanted cardioverters. This evidence already has had an impact on clinical practice and recommendations of scientific societies. On the other hand wireless telemetry can interfere with CE video. CONCLUSION: According to present evidence, small bowel capsule endoscopy can be used in patients with pacemakers and implanted cardioverters after obtaining informed consent concerning the formal existence of contraindication.


Asunto(s)
Endoscopios en Cápsulas/estadística & datos numéricos , Desfibriladores Implantables/estadística & datos numéricos , Falla de Equipo/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Contraindicaciones , Análisis de Falla de Equipo/estadística & datos numéricos , Seguridad de Equipos/estadística & datos numéricos , Humanos
5.
Scand J Gastroenterol ; 48(9): 1088-94, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23834066

RESUMEN

INTRODUCTION: Capsule endoscopy (CE) is firmly established as a standard procedure in the diagnostic algorithm of occult or obscure gastrointestinal bleeding and Crohn's disease. Despite its excellent diagnostic yield, missing expertise, reading time and financial expenditure limit an area-wide availability. A multicentric cooperation might compensate these disadvantages. METHODS: CE device was bought by a central hospital (CH). Requested equipment is transported to the network partner (NP) and the procedure performed at the spot in personal responsibility. Video reading is exclusively done in the CH. RESULTS: Within 10 years, 822 CE (438 m., 384 f.; 63 ± 17 (13-92) years) were performed by 18 cooperating gastroenterological departments. 587/822 (71%) CE were done at NP, 235/822 (29%) in the CH. Between 2002 (n = 39) and 2011 (n = 123) the annual number of CE increased threefold. 95% of the capital investment in each cooperating hospital could be avoided by sharing one workstation within the network. Leading indication for CE was suspected mid-GI-bleeding (80%). Mean latencies between requested date and actual examination were 0 and between equipment's return and report 2 days. 45/191(24%) flexible enteroscopies performed in the CH followed CE findings from NP. DISCUSSION: Our 10 years experience show that mobile use of CE is feasible providing quality parameters similar to a single center solution, increases the number of CE investigations, therefore, improves reading expertise and enables both an area-wide and economic offer for this technique. Additionally, patients with the need for invasive enteroscopy are identified and attracted to that NP who provides an invasive SB endocopy device.


Asunto(s)
Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía Capsular/tendencias , Enfermedades Gastrointestinales/diagnóstico , Relaciones Interinstitucionales , Dolor Abdominal/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiodisplasia/complicaciones , Angiodisplasia/diagnóstico , Endoscopios en Cápsulas/economía , Endoscopía Capsular/economía , Conducta Cooperativa , Ahorro de Costo/economía , Ahorro de Costo/métodos , Enfermedad de Crohn/diagnóstico , Neoplasias Duodenales/diagnóstico , Femenino , Enfermedades Gastrointestinales/complicaciones , Hemorragia Gastrointestinal/etiología , Tránsito Gastrointestinal , Humanos , Neoplasias del Íleon/diagnóstico , Neoplasias del Yeyuno/diagnóstico , Masculino , Persona de Mediana Edad , Úlcera Péptica Hemorrágica/diagnóstico , Grabación en Video , Adulto Joven
6.
Eur J Gastroenterol Hepatol ; 25(3): 327-32, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23183118

RESUMEN

INTRODUCTION: Small bowel capsule endoscopy (SBCE) is a useful diagnostic modality in small bowel disorders. Iron deficiency anaemia (IDA) is one of the most common indications for SBCE. However, there are limited data on the diagnostic yield for IDA alone, and little is known about the clinical impact and long-term outcome of patients following SBCE. AIM: To determine the diagnostic yield of SBCE in IDA and to examine outcome. MATERIALS AND METHODS: A retrospective review of a tertiary referral centre's database over a 21-month time period was carried out. Information on follow-up and management was obtained through chart review. RESULTS: In all, 309 SBCEs were identified, 30% (n=93) for anaemia and in 70% (n=65), follow-up data were available. The small bowel diagnostic yield for IDA was 53% (n=35), including angiodysplasia 49% (n=17), nonspecific inflammation 34% (n=12), active bleeding 11% (n=4) and Crohn's disease 6% (n=2). In addition, 16% (n=10) had abnormalities (gastritis, gastric antral vascular ectasia, duodenitis) outside the small bowel. In all, 42% (n=27) were persistently anaemic after a mean follow-up of 9.3 months. Of these, 52% (n=14) and 48% (n=13) had positive and negative SBCEs, respectively. In total, SBCE led to a change in treatment in 28 patients (44%), of whom 17 (61%) remained anaemic. CONCLUSION: This study shows a high overall diagnostic yield for SBCE in IDA 71% (n=45). Despite the majority, 53% (n=24), of patients with positive tests receiving specific treatment, 61% (n=17) remained anaemic in the long term. SBCE results were not predictive of long-term outcome even when stratified for a change in management.


Asunto(s)
Anemia Ferropénica/etiología , Endoscopios en Cápsulas/estadística & datos numéricos , Enfermedades Intestinales/diagnóstico , Intestino Delgado/patología , Adulto , Anciano , Anciano de 80 o más Años , Anemia Ferropénica/terapia , Angiodisplasia/complicaciones , Angiodisplasia/diagnóstico , Angiodisplasia/terapia , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/terapia , Femenino , Hemorragia Gastrointestinal/complicaciones , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/terapia , Humanos , Enfermedades Intestinales/complicaciones , Enfermedades Intestinales/terapia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Adulto Joven
7.
Int J Med Robot ; 8(3): 337-47, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22508580

RESUMEN

BACKGROUND: A wireless power transmission system is regarded as a practical way of solving power-shortage problems in multifunctional active capsule endoscopes. METHODS: The uniformity of magnetic flux density, frequency stability and orientation stability are used to evaluate power transmission stability, taking into consideration size and safety constraints. Magnetic field safety and temperature rise are also considered. Test benches are designed to measure the relevent parameters. Finally, a mathematical programming model in which these constraints are considered is proposed to improve transmission efficiency. To verify the feasibility of the proposed method, various systems for a wireless active capsule endoscope are designed and evaluated. RESULTS: The optimal power transmission system has the capability to supply continuously at least 500 mW of power with a transmission efficiency of 4.08%. CONCLUSIONS: The example validates the feasibility of the proposed method. Introduction of novel designs enables further improvement of this method.


Asunto(s)
Endoscopios en Cápsulas , Endoscopía Capsular/métodos , Suministros de Energía Eléctrica , Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía Capsular/estadística & datos numéricos , Suministros de Energía Eléctrica/efectos adversos , Suministros de Energía Eléctrica/estadística & datos numéricos , Campos Electromagnéticos/efectos adversos , Diseño de Equipo , Seguridad de Equipos , Humanos
8.
Artículo en Inglés | MEDLINE | ID: mdl-23365963

RESUMEN

This paper presents a real-time magnetic tracking system to be used for tracking an endofunctional capsule intended to aid in the delivery of biomarkers to specific areas in the gastrointestinal (GI) tract. Magnetic technology is chosen due to its significant advantages over others like RF and Ultrasonics. The tracking system is designed to be used with eight magnetic sensors making it less complex than the other proposed systems. The paper describes a new mathematical model which is more accurate than the existing ones, a linear tracking algorithm and system's performance evaluation for three sensor configurations. The algorithm copes with the problem of magnetic field strength drop due to varying orientation of magnet. The minimum average error obtained is 1.37cm/6.85% in a 20×20×20 cm(3) volume for two dimensional sensor configuration.


Asunto(s)
Endoscopios en Cápsulas , Sistemas de Computación , Fenómenos Magnéticos , Algoritmos , Endoscopios en Cápsulas/estadística & datos numéricos , Diseño de Equipo , Humanos , Modelos Teóricos , Dinámicas no Lineales
9.
Lung Cancer ; 72(2): 184-90, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-20846742

RESUMEN

OBJECTIVES: We investigated the capabilities of an endo-cytoscopy system (ECS) that enables microscopic imaging of the tracheobronchial tree during bronchoscopy, including normal bronchial epithelium, dysplastic mucosa and squamous cell carcinoma. METHODS: The newly developed ECS has a 3.2 mm diameter that can be passed through the 4.2 mm working channel of a mother endoscope for insertion of the ECS. It has a high magnification of 570× on a 17 in. video monitor. Twenty-two patients (7 squamous cell carcinoma, 11 squamous dysplasia and 4 after PDT therapies) were underwent white light, NBI light and AFI bronchoscopy. Both abnormal areas of interest and normal bronchial mucosa were stained with 0.5% methylene blue and examined with ECS at high magnification (570×). Histological examinations using haematoxylin and eosin staining were made of biopsied specimens. Analyzed ECS images were compared with the corresponding histological examinations. RESULTS: In normal bronchial mucosa, ciliated columnar epithelial cells were visible. In bronchial squamous dysplasia, superficial cells with abundant cytoplasm were arranged regularly. In squamous cell carcinoma, large, polymorphic tumor cells showed increased cellular densities with irregular stratified patterns. These ECS images corresponded well with the light-microscopic examination of conventional histology. CONCLUSION: ECS was useful for the discrimination between normal bronchial epithelial cells and dysplastic cells or malignant cells during bronchoscopy in real time. This novel technology has an excellent potential to provide in vivo diagnosis during bronchoscopic examinations.


Asunto(s)
Bronquios/patología , Endoscopios en Cápsulas , Carcinoma de Células Escamosas/patología , Neoplasias Pulmonares/patología , Mucosa Respiratoria/patología , Anciano , Broncoscopía/instrumentación , Broncoscopía/métodos , Endoscopios en Cápsulas/estadística & datos numéricos , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/fisiopatología , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/fisiopatología , Masculino , Microscopía Confocal , Persona de Mediana Edad , Coloración y Etiquetado
10.
Dig Dis Sci ; 53(10): 2732-8, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18320313

RESUMEN

INTRODUCTION: The patency capsule may prevent capsule retention in high-risk patients. However data on its use in routine clinical practice is limited. METHODS: Patients referred to our institution between Feb-04 and Jan-07 were reviewed. The following data was collected: presenting symptoms; medical/surgical history; medication; radiology; patency/video capsule result; subsequent investigations; clinical outcomes. RESULTS: 373 patients were referred. In 315 (84%) 'low-risk' patients (no patency capsule): delayed transit occurred in three, with no cases of capsule retention. In 58 (16%) 'high risk' patients (patency capsule): asymptomatic retention occurred in eight, all with pathology despite normal prior barium studies in six; in four cases patency location was incorrectly assessed radiologically, leading to video capsule retention and surgery in one. DISCUSSION: Most patients can safely undergo capsule endoscopy without a patency capsule. The patency capsule appears safe and is indicative of pathology when retained. Assessment of patency capsule location post ingestion can be difficult, and if barium radiology is equivocal a limited abdominal computed tomography (CT) scan is suggested.


Asunto(s)
Endoscopios en Cápsulas/efectos adversos , Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía Capsular/métodos , Anciano , Bario , Seguridad de Equipos , Femenino , Tránsito Gastrointestinal/fisiología , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/epidemiología , Obstrucción Intestinal/fisiopatología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA