Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.197
Filtrar
1.
J Clin Neurosci ; 124: 81-86, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38669906

RESUMEN

BACKGROUND: Delayed-onset seizures after deep brain stimulation (DBS) surgery were seldom reported. This study summarized the clinical characteristics of delayed-onset seizures after subthalamic nucleus (STN) DBS surgery for Parkinson's disease (PD) and analyzed risk factors. METHODS: A single-center retrospective study containing consecutive STN-DBS PD patients from 2006 to 2021 was performed. Seizures occurred during the DBS surgery or within one month after DBS surgery were identified based on routine clinical records. Patients with postoperative magnetic resonance imaging (MRI) were included to further analyze the risk factors for postoperative seizures with univariate and multivariate statistical methods. RESULTS: 341 consecutive PD patients treated with bilateral STN-DBS surgery wereidentified, and five patients experienced seizures after DBS surgery with an incidence of 1.47 %. All seizures of the five cases were characterized as delayed onset with average 12 days post-operatively. All seizures presented as generalized tonic-clonic seizures and didn't recur after the first onset. In those seizures cases, peri-electrode edema was found in both hemispheres without hemorrhage and infarction. The average diameter of peri-electrode edema of patients with seizures was larger than those without seizures (3.15 ± 1.00 cm vs 1.57 ± 1.02 cm, p = 0.005). Multivariate risk factor analysis indicated that seizures were only associated with the diameter of peri-electrode edema (OR 4.144, 95 % CI 1.269-13.530, p = 0.019). CONCLUSIONS: Delayed-onset seizures after STN-DBS surgery in PD patients were uncommon with an incidence of 1.47 % in this study. The seizures were transient and self-limiting, with no developing into chronic epilepsy. Peri-electrode edema was a risk factor for delayed-onset seizures after DBS surgery. Patients with an average peri-electrode edema diameter > 2.70 cm had a higher risk to develop seizures.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Complicaciones Posoperatorias , Convulsiones , Núcleo Subtalámico , Humanos , Estimulación Encefálica Profunda/efectos adversos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Masculino , Femenino , Persona de Mediana Edad , Núcleo Subtalámico/cirugía , Estudios Retrospectivos , Convulsiones/etiología , Convulsiones/epidemiología , Anciano , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Imagen por Resonancia Magnética
2.
J Clin Neurosci ; 123: 196-202, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38604023

RESUMEN

BACKGROUND: Patients with Parkinson's Disease (PD) who receive either asleep image-guided subthalamic nucleus deep brain stimulation (DBS) or the traditional awake technique have comparable motor outcomes. However, there are fewer studies regarding which technique should be chosen for globus pallidus internus (GPi) DBS. This systematic review and meta-analysis aims to compare the accuracy of lead placement and motor outcomes of asleep versus awake GPi DBS PD population. METHODS: We systematically searched PubMed, Embase, and Cochrane for studies comparing asleep vs. awake GPi DBS lead placement in patients with PD. Outcomes were spatial accuracy of lead placement, measured by radial error between intended and actual location, motor improvement measured using (UPDRS III), and postoperative stimulation parameters. Statistical analysis was performed with Review Manager 5.1.7. and OpenMeta [Analyst]. RESULTS: Three studies met inclusion criteria with a total of 247 patients. Asleep DBS was used to treat 192 (77.7 %) patients. Follow-up ranged from 6 to 48 months. Radial error was not statistically different between groups (MD -0.49 mm; 95 % CI -1.0 to 0.02; I2 = 86 %; p = 0.06), with a tendency for higher target accuracy with the asleep technique. There was no significant difference between groups in change on motor function, as measured by UPDRS III, from pre- to postoperative (MD 8.30 %; 95 % CI -4.78 to 21.37; I2 = 67 %, p = 0.2). There was a significant difference in postoperative stimulation voltage, with the asleep group requiring less voltage than the awake group (MD -0.27 V; 95 % CI -0.46 to - 0.08; I2 = 0 %; p = 0.006). CONCLUSION: Our meta-analysis indicates that asleep image-guided GPi DBS presents a statistical tendency suggesting superior target accuracy when compared with the awake standard technique. Differences in change in motor function were not statistically significant between groups.


Asunto(s)
Estimulación Encefálica Profunda , Globo Pálido , Enfermedad de Parkinson , Vigilia , Humanos , Estimulación Encefálica Profunda/métodos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Globo Pálido/cirugía , Vigilia/fisiología
5.
PLoS One ; 19(3): e0298320, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38483943

RESUMEN

BACKGROUND: Deep Brain Stimulation (DBS), applying chronic electrical stimulation of subcortical structures, is a clinical intervention applied in major neurologic disorders. In order to achieve a good clinical effect, accurate electrode placement is necessary. The primary localisation is typically based on presurgical MRI imaging, often followed by intra-operative electrophysiology recording to increase the accuracy and to compensate for brain shift, especially in cases where the surgical target is small, and there is low contrast: e.g., in Parkinson's disease (PD) and in its common target, the subthalamic nucleus (STN). METHODS: We propose a novel, fully automatic method for intra-operative surgical navigation. First, the surgical target is segmented in presurgical MRI images using a statistical shape-intensity model. Next, automated alignment with intra-operatively recorded microelectrode recordings is performed using a probabilistic model of STN electrophysiology. We apply the method to a dataset of 120 PD patients with clinical T2 1.5T images, of which 48 also had available microelectrode recordings (MER). RESULTS: The proposed segmentation method achieved STN segmentation accuracy around dice = 0.60 compared to manual segmentation. This is comparable to the state-of-the-art on low-resolution clinical MRI data. When combined with electrophysiology-based alignment, we achieved an accuracy of 0.85 for correctly including recording sites of STN-labelled MERs in the final STN volume. CONCLUSION: The proposed method combines image-based segmentation of the subthalamic nucleus with microelectrode recordings to estimate their mutual location during the surgery in a fully automated process. Apart from its potential use in clinical targeting, the method can be used to map electrophysiological properties to specific parts of the basal ganglia structures and their vicinity.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Estimulación Encefálica Profunda/métodos , Imagen por Resonancia Magnética , Microelectrodos , Electrofisiología
6.
J Med Imaging Radiat Sci ; 55(1): 146-157, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38342737

RESUMEN

BACKGROUND: Stereotaxic Radiosurgery (SRS) is a non-invasive lesioning technique for movement disorders when patients cannot undergo DBS due to medical comorbidities. OBJECTIVE: To describe and summarize the literature on SRS's application and physical parameters for Parkinson's disease (PD) motor symptoms. METHODS: The MEDLINE/PUBMED and EMBASE databases were searched in July 2022 following the PRISMA guideline. Two independent reviewers screened data from 425 articles. The level of evidence followed the Oxford Centre for Evidence-Based Medicine. Pertinent details for each study regarding participants, physical parameters, and results were extracted. RESULTS: Twelve studies reported that 454 PD patients underwent Gamma KnifeⓇ (GK). The mean improvement time of the treated symptoms was three months after GK. Tremor is the most common symptom investigated, with success rates ranging from 47.5% to 93.9%. Few studies were conducted for caudatotomy (GKC) and pallidotomy (GKP), which presented an improvement for dyskinesia and bradykinesia. Physical parameters were similar with doses ranging from 110 to 200 Gy, use of a 4-mm collimator with an advanced imaging locator system, and coordinates were obtained from available stereotactic atlases. CONCLUSIONS: GK thalamotomy is a good alternative for treating tremor; however, its effects are delayed, and there are cases in which it can regress after years. The outcomes of GKC and GKP seem to be promising. The existing studies are more limited, and effects need to be better investigated.


Asunto(s)
Enfermedad de Parkinson , Radiocirugia , Humanos , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/radioterapia , Enfermedad de Parkinson/cirugía , Temblor/etiología , Temblor/cirugía , Radiocirugia/métodos , Tálamo/cirugía
7.
Clin Neurol Neurosurg ; 238: 108174, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38422743

RESUMEN

BACKGROUND: Deep brain stimulation (DBS) surgery is an effective treatment for movement disorders. Introduction of intracranial air following dura opening in DBS surgery can result in targeting inaccuracy and suboptimal outcomes. We develop and evaluate a simple method to minimize pneumocephalus during DBS surgery. METHODS: A retrospective analysis of prospectively collected data was performed on patients undergoing DBS surgery at our institution from 2014 to 2022. A total of 172 leads placed in 89 patients undergoing awake or asleep DBS surgery were analyzed. Pneumocephalus volume was compared between leads placed with PMT and leads placed with standard dural opening. (112 PMT vs. 60 OPEN). Immediate post-operative high-resolution CT scans were obtained for all leads placed, from which pneumocephalus volume was determined through a semi-automated protocol with ITK-SNAP software. Awake surgery was conducted with the head positioned at 15-30°, asleep surgery was conducted at 0°. RESULTS: PMT reduced pneumocephalus from 11.2 cm3±9.2 to 0.8 cm3±1.8 (P<0.0001) in the first hemisphere and from 7.6 cm3 ± 8.4 to 0.43 cm3 ± 0.9 (P<0.0001) in the second hemisphere. No differences in adverse events were noted between PMT and control cases. Lower rates of post-operative headache were observed in PMT group. CONCLUSION: We present and validate a simple yet efficacious technique to reduce pneumocephalus during DBS surgery.


Asunto(s)
Neoplasias Encefálicas , Estimulación Encefálica Profunda , Enfermedad de Parkinson , Neumocéfalo , Humanos , Estimulación Encefálica Profunda/efectos adversos , Estimulación Encefálica Profunda/métodos , Estudios Retrospectivos , Neumocéfalo/diagnóstico por imagen , Neumocéfalo/etiología , Neumocéfalo/prevención & control , Neoplasias Encefálicas/etiología , Vigilia , Enfermedad de Parkinson/cirugía , Enfermedad de Parkinson/etiología
8.
Stereotact Funct Neurosurg ; 102(2): 83-92, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38286119

RESUMEN

INTRODUCTION: Deep brain stimulation (DBS) is a routine neurosurgical procedure utilized to treat various movement disorders including Parkinson's disease (PD), essential tremor (ET), and dystonia. Treatment efficacy is dependent on stereotactic accuracy of lead placement into the deep brain target of interest. However, brain shift attributed to pneumocephalus can introduce unpredictable inaccuracies during DBS lead placement. This study aimed to determine whether intracranial air is associated with brain shift in patients undergoing staged DBS surgery. METHODS: We retrospectively evaluated 46 patients who underwent staged DBS surgery for PD, ET, and dystonia. Due to the staged nature of DBS surgery at our institution, the first electrode placement is used as a concrete fiducial marker for movement in the target location. Postoperative computed tomography (CT) images after the first electrode implantation, as well as preoperative, and postoperative CT images after the second electrode implantation were collected. Images were analyzed in stereotactic targeting software (BrainLab); intracranial air was manually segmented, and electrode shift was measured in the x, y, and z plane, as well as a Euclidian distance on each set of merged CT scans. A Pearson correlation analysis was used to determine the relationship between intracranial air and brain shift, and student's t test was used to compare means between patients with and without radiographic evidence of intracranial air. RESULTS: Thirty-six patients had pneumocephalus after the first electrode implantation, while 35 had pneumocephalus after the second electrode implantation. Accumulation of intracranial air following the first electrode implantation (4.49 ± 6.05 cm3) was significantly correlated with brain shift along the y axis (0.04 ± 0.35 mm; r (34) = 0.36; p = 0.03), as well as the Euclidean distance of deviation (0.57 ± 0.33 mm; r (34) = 0.33; p = 0.05) indicating statistically significant shift on the ipsilateral side. However, there was no significant correlation between intracranial air and brain shift following the second electrode implantation, suggesting contralateral shift is minimal. Furthermore, there was no significant difference in brain shift between patients with and without radiographic evidence of intracranial air following both electrode implantation surgeries. CONCLUSION: Despite observing volumes as high as 22.0 cm3 in patients with radiographic evidence of pneumocephalus, there was no significant difference in brain shift when compared to patients without pneumocephalus. Furthermore, the mean magnitude of brain shift was <1.0 mm regardless of whether pneumocephalus was presenting, suggesting that intracranial air accumulation may not produce clinical significant brain shift in our patients.


Asunto(s)
Estimulación Encefálica Profunda , Distonía , Trastornos Distónicos , Temblor Esencial , Enfermedad de Parkinson , Neumocéfalo , Humanos , Estimulación Encefálica Profunda/efectos adversos , Estimulación Encefálica Profunda/métodos , Distonía/terapia , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Electrodos Implantados/efectos adversos , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Temblor Esencial/diagnóstico por imagen , Temblor Esencial/cirugía , Trastornos Distónicos/terapia
9.
J Parkinsons Dis ; 14(1): 111-119, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38189764

RESUMEN

BACKGROUND: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a preferred treatment for parkinsonian patients with severe motor fluctuations. Proper targeting of the STN sensorimotor segment appears to be a crucial factor for success of the procedure. The recent introduction of directional leads theoretically increases stimulation specificity in this challenging area but also requires more precise stimulation parameters. OBJECTIVE: We investigated whether commercially available software for image guided programming (IGP) could maximize the benefits of DBS by informing the clinical standard care (CSC) and improving programming workflows. METHODS: We prospectively analyzed 32 consecutive parkinsonian patients implanted with bilateral directional leads in the STN. Double blind stimulation parameters determined by CSC and IGP were assessed and compared at three months post-surgery. IGP was used to adjust stimulation parameters if further clinical refinement was required. Overall clinical efficacy was evaluated one-year post-surgery. RESULTS: We observed 78% concordance between the two electrode levels selected by the blinded IGP prediction and CSC assessments. In 64% of cases requiring refinement, IGP improved clinical efficacy or reduced mild side effects, predominantly by facilitating the use of directional stimulation (93% of refinements). CONCLUSIONS: The use of image guided programming saves time and assists clinical refinement, which may be beneficial to the clinical standard care for STN-DBS and further improve the outcomes of DBS for PD patients.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Estimulación Encefálica Profunda/métodos , Enfermedad de Parkinson/cirugía , Núcleo Subtalámico/cirugía , Resultado del Tratamiento , Flujo de Trabajo , Método Doble Ciego
11.
Exp Neurol ; 374: 114694, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38272159

RESUMEN

Parkinson's disease (PD) is a relentlessly progressive and currently incurable neurodegenerative disease with significant unmet medical needs. Since PD stems from the degeneration of midbrain dopaminergic (DA) neurons in a defined brain location, PD patients are considered optimal candidates for cell replacement therapy. Clinical trials for cell transplantation in PD are beginning to re-emerge worldwide with a new focus on induced pluripotent stem cells (iPSCs) as a source of DA neurons since they can be derived from adult somatic cells and produced in large quantities under current good manufacturing practices. However, for this therapeutic strategy to be realized as a viable clinical option, fundamental translational challenges need to be addressed including the manufacturing process, purity and efficacy of the cells, the method of delivery, the extent of host reinnervation and the impact of patient-centered adjunctive interventions. In this study we report on the impact of physical and cognitive training (PCT) on functional recovery in the nonhuman primate (NHP) model of PD after cell transplantation. We observed that at 6 months post-transplant, the PCT group returned to normal baseline in their daily activity measured by actigraphy, significantly improved in their sensorimotor and cognitive tasks, and showed enhanced synapse formation between grafted cells and host cells. We also describe a robust, simple, efficient, scalable, and cost-effective manufacturing process of engraftable DA neurons derived from iPSCs. This study suggests that integrating PCT with cell transplantation therapy could promote optimal graft functional integration and better outcome for patients with PD.


Asunto(s)
Células Madre Pluripotentes Inducidas , Enfermedades Neurodegenerativas , Enfermedad de Parkinson , Adulto , Animales , Humanos , Neuronas Dopaminérgicas/fisiología , Células Madre Pluripotentes Inducidas/trasplante , Callithrix , Entrenamiento Cognitivo , Enfermedad de Parkinson/cirugía , Trasplante de Células Madre/métodos , Diferenciación Celular/fisiología
12.
Neural Netw ; 170: 18-31, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37972454

RESUMEN

During the Deep Brain Stimulation (DBS) surgery for Parkinson's disease (PD), the main goal is to place the permanent stimulating electrode into an area of the brain that becomes pathologically hyperactive. This area, called Subthalamic Nucleus (STN), is small and located deep within the brain. Therefore, the main challenge is the precise localization of the STN region, considering various measurement errors and artifacts. In this paper, we have designed and developed a computer-aided decision support system for neurosurgical DBS surgery. The implementation of this system provides a novel method for calculating the expected position of the stimulating electrode based on the recordings of the electrical activity of brain tissue. The artificial neural network with attention is used to classify the microelectrode recordings and determine the final position of the stimulating electrode within the STN area. Experiments have verified the utility and efficiency of our system. The tests were carried out on many recordings collected during DBS surgeries, giving encouraging results. The experimental results demonstrate that deep learning methods extended with self-attention blocks compete with the other solutions. They provide significant robustness to recording artifacts and improve the accuracy of the stimulating electrode placement.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Estimulación Encefálica Profunda/métodos , Microelectrodos , Electrodos Implantados , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/cirugía , Núcleo Subtalámico/fisiología
13.
World Neurosurg ; 181: e346-e355, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37839566

RESUMEN

BACKGROUND: Deep brain stimulation of the subthalamic nucleus (STN-DBS) for Parkinson's disease can be performed with intraoperative neurophysiological and radiographic guidance. Conventional T2-weighted magnetic resonance imaging sequences, however, often fail to provide definitive borders of the STN. Novel magnetic resonance imaging sequences, such as susceptibility-weighted imaging (SWI), might better localize the STN borders and facilitate radiographic targeting. We compared the radiographic location of the dorsal and ventral borders of the STN using SWI with intraoperative microelectrode recording (MER) during awake STN-DBS for Parkinson's disease. METHODS: Thirteen consecutive patients who underwent placement of 24 STN-DBS leads for Parkinson's disease were analyzed retrospectively. Preoperative targeting was performed with SWI, and MER data were obtained from intraoperative electrophysiology records. The boundaries of the STN on SWI were identified by a blinded investigator. RESULTS: The final electrode position differed significantly from the planned coordinates in depth but not in length or width, indicating that MER guided the final electrode depth. When we compared the boundaries of the STN by MER and SWI, SWI accurately predicted the entry into the STN but underestimated the length and ventral boundary of the STN by 1.2 mm. This extent of error approximates the span of a DBS contact and could affect the placement of directional contacts within the STN. CONCLUSIONS: MER might continue to have a role in STN-DBS. This could potentially be mitigated by further refinement of imaging protocols to better image the ventral boundary of the STN.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Núcleo Subtalámico/diagnóstico por imagen , Núcleo Subtalámico/cirugía , Núcleo Subtalámico/fisiología , Estimulación Encefálica Profunda/métodos , Microelectrodos , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/cirugía , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Electrodos Implantados
14.
Neuromodulation ; 27(3): 409-421, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37462595

RESUMEN

OBJECTIVE: This systematic review is conducted to identify, compare, and analyze neurophysiological feature selection, extraction, and classification to provide a comprehensive reference on neurophysiology-based subthalamic nucleus (STN) localization. MATERIALS AND METHODS: The review was carried out using the methods and guidelines of the Kitchenham systematic review and provides an in-depth analysis on methods proposed on STN localization discussed in the literature between 2000 and 2021. Three research questions were formulated, and 115 publications were identified to answer the questions. RESULTS: The three research questions formulated are answered using the literature found on the respective topics. This review discussed the technologies used in past research, and the performance of the state-of-the-art techniques is also reviewed. CONCLUSION: This systematic review provides a comprehensive reference on neurophysiology-based STN localization by reviewing the research questions other new researchers may also have.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Núcleo Subtalámico/cirugía , Estimulación Encefálica Profunda/métodos , Neurofisiología , Enfermedad de Parkinson/cirugía
16.
Neurosurg Rev ; 47(1): 7, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38063935

RESUMEN

Parkinson's disease (PD) is characterized by cardinal motor signs: 4-6 Hz resting tremor, rigidity, and bradykinesia. In addition, 3-18% of PD patients have camptocormia, an abnormal forward flexion of the thoracolumbar spine, which may have a negative impact on patients' quality of life. Different possible treatments have been suggested for such a condition, but no one is resolutive. This study aims to define the possible impact of DBS, with selective targeting on the dorsal-lateral region of the STN, on the sagittal balance of patients affected by PD. Among all patients that have undergone DBS procedures in our institution, we selected eight subjects, four females and four males, with selective targeting on the dorsal-lateral region of the subthalamic nucleus (STN) because of camptocormia and other severe postural changes. Radiological assessments of spinal balance parameters before surgery and at 6 and 12 months postoperatively were carried out. Comparison of preoperative and postoperative spine X-ray data showed a statistically significant improvement in dorsal kyphosis angle (D-Cobb) 12 months after the operation. Deep brain stimulation with selective targeting of the dorsal lateral part of the STN may induce changes of the posture in patients with Parkinson's disease 12 months after the operation, which appears to improve in this small sample size, but larger observational and controlled trials would be required to confirm this observation.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Curvaturas de la Columna Vertebral , Masculino , Femenino , Humanos , Enfermedad de Parkinson/cirugía , Estimulación Encefálica Profunda/métodos , Calidad de Vida , Curvaturas de la Columna Vertebral/cirugía
18.
Clin Neurophysiol ; 156: 196-206, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37972531

RESUMEN

OBJECTIVE: To assess transcranial sonography (TCS) as stand-alone tool and in combination with microelectrode recordings (MER) as a method for the postoperative localization of deep brain stimulation (DBS) electrodes in the subthalamic nucleus (STN). METHODS: Individual dorsal and ventral boundaries of STN (n = 12) were determined on intraoperative MER. Postoperatively, a standardized TCS protocol was applied to measure medio-lateral, anterior-posterior and rostro-caudal electrode position using visualized reference structures (midline, substantia nigra). TCS and combined TCS-MER data were validated using fusion-imaging and clinical outcome data. RESULTS: Test-retest reliability of standard TCS measures of electrode position was excellent. Computed tomography and TCS measures of distance between distal electrode contact and midline agreed well (Pearson correlation; r = 0.86; p < 0.001). Comparing our "gold standard" of rostro-caudal electrode localization relative to STN boundaries, i.e. combining MRI-based stereotaxy and MER data, with the combination of TCS and MER data, the measures differed by 0.32 ± 0.87 (range, -1.35 to 1.25) mm. Combined TCS-MER data identified the clinically preferred electrode contacts for STN-DBS with high accuracy (Cohens kappa, 0.86). CONCLUSIONS: Combined TCS-MER data allow for exact localization of STN-DBS electrodes. SIGNIFICANCE: Our method provides a new option for monitoring of STN-DBS electrode location and guidance of DBS programming in Parkinson's disease.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Microelectrodos , Reproducibilidad de los Resultados , Estimulación Encefálica Profunda/métodos , Núcleo Subtalámico/diagnóstico por imagen , Núcleo Subtalámico/cirugía , Núcleo Subtalámico/fisiología , Imagen por Resonancia Magnética/métodos , Electrodos Implantados
20.
J Neurol Neurosurg Psychiatry ; 95(1): 86-96, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-37679029

RESUMEN

BACKGROUND: Deep brain stimulation (DBS) is commonly performed with patients awake to perform intraoperative microelectrode recordings and/or macrostimulation testing to guide final electrode placement. Supplemental information from atlas-based databases derived from prior patient data and visualised as efficacy heat maps transformed and overlaid onto preoperative MRIs can be used to guide preoperative target planning and intraoperative final positioning. Our quantitative analysis of intraoperative testing and corresponding changes made to final electrode positioning aims to highlight the value of intraoperative neurophysiological testing paired with image-based data to optimise final electrode positioning in a large patient cohort. METHODS: Data from 451 patients with movement disorders treated with 822 individual DBS leads at a single institution from 2011 to 2021 were included. Atlas-based data was used to guide surgical targeting. Intraoperative testing data and coordinate data were retrospectively obtained from a large patient database. Medical records were reviewed to obtain active contact usage and neurologist-defined outcomes at 1 year. RESULTS: Microelectrode recording firing profiles differ per track, per target and inform the locations where macrostimulation testing is performed. Macrostimulation performance correlates with the final electrode track chosen. Centroids of atlas-based efficacy heat maps per target were close in proximity to and may predict active contact usage at 1 year. Overall, patient outcomes at 1 year were improved for patients with better macrostimulation response. CONCLUSIONS: Atlas-based imaging data is beneficial for target planning and intraoperative guidance, and in conjunction with intraoperative neurophysiological testing during awake DBS can be used to individualize and optimise final electrode positioning, resulting in favourable outcomes.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Humanos , Estimulación Encefálica Profunda/métodos , Estudios Retrospectivos , Vigilia , Enfermedad de Parkinson/cirugía , Imagen por Resonancia Magnética , Microelectrodos , Electrodos Implantados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA