Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Braz J Cardiovasc Surg ; 39(4): e20230438, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038201

RESUMEN

OBJECTIVES: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). METHODS: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. RESULTS: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). CONCLUSION: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.


Asunto(s)
Aorta , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Femenino , Estudios Retrospectivos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Anciano , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Aorta/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/mortalidad , Válvula Tricúspide/cirugía , Progresión de la Enfermedad , Factores de Riesgo , Resultado del Tratamiento , Complicaciones Posoperatorias
3.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048253

RESUMEN

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Factores de Riesgo , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Medición de Riesgo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Estados Unidos/epidemiología , Índice de Severidad de la Enfermedad , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Anciano de 80 o más Años , Persona de Mediana Edad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad
4.
JACC Cardiovasc Interv ; 17(14): 1676-1679, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048254
5.
BMC Cardiovasc Disord ; 24(1): 367, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014301

RESUMEN

OBJECTIVE: To investigate the accuracy and consistency of MDCT and TEE in the preoperative assessment of aortic root surgery. METHODS: From January 2021 to September 2022, 118 patients who underwent aortic root surgery were included in this study. All patients underwent high-quality preoperative MDCT and TEE examinations, and the examination results were independently measured and assessed by two senior radiologists or ultrasound specialists. Bland-Altman analysis and Pearson correlation testing were employed to assess the correlation and consistency between MDCT and TEE. These analyses were then compared with actual intraoperative measurement data. RESULTS: Among all the patients, 73 (61.86%) had tricuspid aortic valve (TAV), and 45 (38.14%) had bicuspid aortic valve (BAV). A comparison between the TEE and MDCT measurements showed that for the annulus diameter, the area-derived diameter had the best correlation and agreement. For the sinus of Valsalva diameter, the circumference-derived diameter was optimal. However, for the STJ diameter, the minimum cross-sectional diameter showed the best agreement with TEE. In contrast, measurements of geometric height showed a weaker correlation and agreement. CONCLUSION: Contrast-enhanced MDCT can be a valuable tool for perioperative evaluation in aortic root surgery, with good correlation, consistency, and feasibility when compared to TEE. The choice of MDCT measurement methodology, specifically area-derived and circumference-derived diameter, proved to be more accurate than other methods. Further research is required to enhance the understanding of aortic valve repair and associated imaging techniques.


Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Ecocardiografía Transesofágica , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Masculino , Femenino , Persona de Mediana Edad , Anciano , Reproducibilidad de los Resultados , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Adulto , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Cuidados Preoperatorios
6.
Asian Cardiovasc Thorac Ann ; 32(5): 285-293, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38831608

RESUMEN

OBJECTIVE: Partial upper sternotomy is preferred for isolated aortic valve replacement because of its optimal surgical visibility and favorable cosmetic outcomes; however, it is not commonly used for aortic root surgery, and the conventional median sternotomy is still the preferred method for most surgeons. We aimed to compare the safety and effectiveness of a minimally invasive approach (partial sternotomy [PS]) and conventional approach (median sternotomy [FS]) for aortic root surgery. METHODS: Patients who underwent aortic root surgery at our hospital from 2016 to 2021 were retrospectively enrolled and divided into two groups. After propensity score matching, the conventional group included 156 patients and the minimally invasive group-57 patients. RESULTS: Bicuspid aortic valves were observed in 63 (40.4%) and 33 (57.9%) patients in the FS and PS groups, respectively. Valve-sparing surgery was performed on 69 (44.2%) and 30 (52.6%) patients in the FS and PS groups, respectively. The minimally invasive approach was beneficial in terms of blood loss during the first 24 h after surgery (p = 0.029) and postoperative blood transfusion (p = 0.023). The survival rates and freedom from reoperation or severe aortic regurgitation after the David procedure were comparable between the standard and minimally invasive groups (p = 0.25; p = 0.66) at mid-term follow-up. CONCLUSIONS: A minimally invasive approach for aortic root surgery can be safely performed as the standard approach. Partial upper sternotomy has the advantage of lower blood loss in the early postoperative period and does not negatively affect the results of valve-sparing root replacement.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis Vascular , Esternotomía , Humanos , Masculino , Femenino , Estudios Retrospectivos , Esternotomía/efectos adversos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Anciano , Factores de Riesgo , Factores de Tiempo , Complicaciones Posoperatorias/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Adulto , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Medición de Riesgo , Toma de Decisiones Clínicas , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Pérdida de Sangre Quirúrgica
7.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819623

RESUMEN

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Femenino , Masculino , Estudios Retrospectivos , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Valvuloplastia con Balón/efectos adversos , Factores de Riesgo , Estados Unidos , Stents
9.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios Retrospectivos
10.
Am Heart J ; 274: 65-74, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38701961

RESUMEN

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Estudios Prospectivos , Método Simple Ciego , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Masculino , Femenino
13.
Int J Cardiol ; 409: 132201, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38782071

RESUMEN

BACKGROUND: To date, whether ascending aorta dilation (AAD) should be considered a contraindication for transcatheter aortic valve replacement (TAVR) remains a topic of debate.. OBJECTIVE: The study investigated the clinical outcome of TAVR in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by AAD. METHODS: We included patients with BAV-AS who underwent TAVR between 2012 and 2019. We collected patient perioperative clinical data., tracked clinical outcomes for over four years post-TAVR, and obtained echocardiography images one year postoperatively. The Kaplan-Meier method was employed for analyzing both unadjusted and adjusted survival data, which was compared using the log-rank test. COX regression and nomograms were used to assess the impact of AAD on post-TAVR clinical outcomes in patients with aortic stenosis (AS), with all-cause mortality as the primary clinical endpoint. RESULTS: A total of 111 BAV patients were included in this study. Long-term follow-up showed an increased mortality risk in patients with BAV-AAD (adjusted Kaplan-Meier analysis: P = .02/0.001). Cox correlation analysis indicated that age (OR = 1.137; P = .034), AAD (OR = 3.51; P = .038), and postoperative left ventricular pressure (LVSP) (OR: 0.959; P = .044) were predictive factors for mortality more than four years after TAVR in patients with BAV. The area under the curve of the Nomogram predicting long-term survival for the training set of patients based on the above metrics was 0.845 (95% CI: 0.696-0.994). Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion (0.29 [0-0.34] vs. -1 [-3.3-1] mm/month, P = .001) and a smaller proportion of AA diameter reduction (7.1% vs. 53.7%, P = .001) in patients who died. CONCLUSIONS: Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality, and clinical prediction models, including AAD age and postoperative LVSP, may predict long-term patient survival. CONDENSED ABSTRACT: The study investigated the clinical outcome of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by ascending aorta dilation (AAD). Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality. AAD, age and postoperative LVSP, may predict long-term patient survival. Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion and a smaller proportion of AA diameter reduction in patients who died. A high postoperative AAD expansion rate may indicate an adverse clinical outcome. Surgery regimens for tolerable BAV-AADs and can be considered as a treatment option.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Anciano , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Resultado del Tratamiento , Estudios de Seguimiento , Estudios Retrospectivos , Anciano de 80 o más Años , Factores de Tiempo , Persona de Mediana Edad
14.
Heart Lung ; 67: 144-151, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38762962

RESUMEN

BACKGROUND: Despite comprising almost half of all patients undergoing valvular repair, data on transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic stenosis (BAS) are limited. OBJECTIVE: We aimed to evaluate whether there are any sex differences in trends and outcomes of TAVR in this population. METHODS: We utilized the National Inpatient Sample from 2012 to 2020 to identify admissions with BAS who underwent TAVR and analyzed trends and outcomes. Our primary outcome was in-hospital mortality and secondary outcomes were in-hospital complications. We used two models to adjust for demographics (A) and interventions (B). RESULTS: Between 2012 to 2020, there were 76,540 hospitalizations for BAS patients who underwent AVR, among which 6,010 (7.9 %) underwent TAVR. There was an overall increasing trend in number of TAVR cases with a decreasing trend in mortality (2013: 8.7 %, 2020: 1.3 %). TAVR was performed more in males (61.1% vs 38.9 %). Despite the worse baseline characteristics in males, in-hospital mortality (2.4% vs. 1.5 %; OR: 1.584; 95 % CI: 0.621-4.038; p = 0.335) and secondary outcomes were similar across both sexes, even after adjusting for demographics and interventions. CONCLUSION: TAVR in BAS has grown rapidly in the last decade. Males comprised the majority and had more comorbidities, but mortality and complications were similar in both sexes. Despite the increasing number of cases, a decreasing trend in mortality was observed for both sexes ultimately approaching that of SAVR, suggesting that TAVR may be a safe alternative among eligible males and females with bicuspid AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Mortalidad Hospitalaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Mortalidad Hospitalaria/tendencias , Anciano , Factores Sexuales , Estados Unidos/epidemiología , Anciano de 80 o más Años , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Factores de Riesgo , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones
15.
Clin Interv Aging ; 19: 695-703, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711477

RESUMEN

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Complicaciones Posoperatorias , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Anciano , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Persona de Mediana Edad , Factores de Riesgo , Enfermedades de las Válvulas Cardíacas/cirugía
17.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38561108

RESUMEN

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Sistema de Registros , Humanos , Masculino , Femenino , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Persona de Mediana Edad , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/epidemiología , Adulto , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Seguimiento , Italia/epidemiología
19.
Comput Methods Programs Biomed ; 250: 108173, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38615386

RESUMEN

BACKGROUND AND OBJECTIVE: The conventional valve stents that are cylindrical in shape will become elliptical when implanted in bicuspid aortic valve, thereby reducing the durability of the artificial valve. In this study, a new design of valve stent is presented where valve stents have elliptical cross-section at the annulus and it is expected to have better expandability and circle shape during the interaction between the stent and bicuspid aortic valve, thereby extending the durability of artificial valve. METHODS: Finite element method (FEM) is used to study the mechanical behavior of the novel valve stent in the bicuspid aortic valve. The effects of three matching relationship between the ellipticity of the stents and the ellipticity of the annulus (i.e., the ellipticity of the stent is greater than, equal to and less than the annulus ellipticity, respectively) on the mechanical behavior of stent expansion are studied. In addition, the expansion mechanical behavior of the novel valve stent at different implantation depths is also compared. RESULTS: Results indicate that novel valve stent implantation with elliptical features is superior to conventional circular valve stent. When the novel valve stent ellipticity is less than the annulus ellipticity, the ellipticity of the novel valve stent after implantation is smaller than that of the conventional circular valve stent. This indicated that the novel valve stent has better expandability and post-expansion shape, making artificial valve to have better durability. The risk of paravalvular leak after implantation is lowest when the novel valve stent ellipticity is less than annulus ellipticity. When the novel valve stent ellipticity coincides with annulus ellipticity, the aortic wall is subjected to greatest stress. With the increase of implantation depth, the stress on the novel valve stent decrease. CONCLUSIONS: This study might provide insights for improving stent design for bicuspid aortic valve.


Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Análisis de Elementos Finitos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Stents , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Humanos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estrés Mecánico , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedad de la Válvula Aórtica/cirugía
20.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577939

RESUMEN

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Factores de Tiempo , Anciano , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Recuperación de la Función , Hemodinámica , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA