Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.649
Filtrar
1.
Ann Clin Lab Sci ; 54(2): 246-250, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38802159

RESUMEN

Von Willebrand disease (VWD) is the most common inherited bleeding disorder. It is primarily attributed to malfunctioning or deficient Von Willebrand factor (VWF). Thromboelastography (TEG) has emerged as a valuable tool for assessing coagulation dynamics and guiding transfusion therapy in bleeding patients. Given this, we present a case study of a 23-year-old pregnant female with a past medical history of type 2B VWD, wherein TEG was employed to optimize disease screening and therapy monitoring while minimizing costs and preventing complications associated with low platelet counts. This case underscores the potential utility of TEG in enhancing the care of VWD patients, particularly in unique critical settings such as pregnancy.


Asunto(s)
Tromboelastografía , Enfermedades de von Willebrand , Humanos , Tromboelastografía/métodos , Femenino , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/sangre , Embarazo , Adulto Joven , Factor de von Willebrand/metabolismo , Factor de von Willebrand/análisis , Adulto
2.
Thromb Haemost ; 122(2): 226-239, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33385180

RESUMEN

The multimeric plasma glycoprotein (GP) von Willebrand factor (VWF) is best known for recruiting platelets to sites of injury during primary hemostasis. Generally, mutations in the VWF gene lead to loss of hemostatic activity and thus the bleeding disorder von Willebrand disease. By employing cone and platelet aggregometry and microfluidic assays, we uncovered a platelet GPIIb/IIIa-dependent prothrombotic gain of function (GOF) for variant p.Pro2555Arg, located in the C4 domain, leading to an increase in platelet aggregate size. We performed complementary biophysical and structural investigations using circular dichroism spectra, small-angle X-ray scattering, nuclear magnetic resonance spectroscopy, molecular dynamics simulations on the single C4 domain, and dimeric wild-type and p.Pro2555Arg constructs. C4-p.Pro2555Arg retained the overall structural conformation with minor populations of alternative conformations exhibiting increased hinge flexibility and slow conformational exchange. The dimeric protein becomes disordered and more flexible. Our data suggest that the GOF does not affect the binding affinity of the C4 domain for GPIIb/IIIa. Instead, the increased VWF dimer flexibility enhances temporal accessibility of platelet-binding sites. Using an interdisciplinary approach, we revealed that p.Pro2555Arg is the first VWF variant, which increases platelet aggregate size and shows a shear-dependent function of the VWF stem region, which can become hyperactive through mutations. Prothrombotic GOF variants of VWF are a novel concept of a VWF-associated pathomechanism of thromboembolic events, which is of general interest to vascular health but not yet considered in diagnostics. Thus, awareness should be raised for the risk they pose. Furthermore, our data implicate the C4 domain as a novel antithrombotic drug target.


Asunto(s)
Mutación con Ganancia de Función , Variación Genética , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/metabolismo , Factor de von Willebrand/genética , Mutación con Ganancia de Función/genética , Hemostasis , Humanos , Agregación Plaquetaria , Dominios Proteicos/genética , Enfermedades de von Willebrand/sangre , Factor de von Willebrand/metabolismo
3.
Am J Hematol ; 97(1): 60-67, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34710246

RESUMEN

Iron deficiency anemia is associated with heavy menstrual bleeding (HMB) and, by extension, a bleeding disorder (BD). It is unknown if iron deficiency without anemia is associated with a BD in adolescents. Moreover, the threshold of ferritin associated with fatigue in adolescents with HMB is unclear. In this multicenter study, we enrolled adolescents with HMB without BD. Participants underwent BD and anemia work-up in Young Women's Hematology Clinics and completed the Peds QL™ fatigue scale. BDs were defined as von Willebrand Disease, platelet function defect, clotting factor deficiencies, and hypermobility syndrome. Two hundred and fifty consecutive adolescents were enrolled, of whom 196 met eligibility criteria. Overall, 43% (95% confidence interval: 36%-50%) were diagnosed with BD. A total of 61% (n = 119) had serum ferritin levels < 15 ng/mL, 23.5% (n = 46) had iron deficiency only, and 37% (n = 73) had iron deficiency anemia. Low ferritin or ferritin dichotomized as < 15 or ≥ 15 ng/mL was not associated with BD on univariable analysis (p = .24) or when accounting for age, race, ethnicity, body mass index, and hemoglobin (p = .35). A total of 85% had total fatigue score below the population mean of 80.5, and 52% (n = 102) were > 2 SD (or < 54) below the mean, the cut-off associated with severe fatigue. A ferritin threshold of < 6 ng/mL had a specificity of 79.8% but a sensitivity of 36% for severe fatigue. In conclusion, iron deficiency without anemia is not a predictor of BD in adolescents with HMB in a specialty setting. Severe fatigue, especially sleep fatigue, is prevalent in adolescents with BD. Ferritin of < 6 ng/mL has ~80% specificity for severe fatigue in adolescents with HMB.


Asunto(s)
Fatiga/complicaciones , Trastornos Hemorrágicos/complicaciones , Deficiencias de Hierro/complicaciones , Adolescente , Adulto , Fatiga/sangre , Femenino , Ferritinas/análisis , Trastornos Hemorrágicos/sangre , Humanos , Deficiencias de Hierro/sangre , Masculino , Menorragia/sangre , Menorragia/complicaciones , Adulto Joven , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/complicaciones
4.
Anesth Analg ; 134(2): 312-321, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34903705

RESUMEN

BACKGROUND: Coagulopathic bleeding is common during adult extracorporeal membrane oxygenation (ECMO), and acquired von Willebrand syndrome is a contributing factor. We compared ECMO patient blood samples that were treated in vitro with recombinant von Willebrand Factor concentrate and plasma-derived von Willebrand Factor concentrate. Our hypothesis was that recombinant von Willebrand Factor (vWF) would have greater efficacy in increasing vWF function. Secondarily, we hypothesized that recombinant vWF would have less impact on thrombin generation. METHODS: Thirty ECMO patients and 10 cardiac surgical controls were enrolled in the study. ECMO patient blood samples were treated in vitro with low- and high-dose recombinant vWFs and low- and high-dose plasma-derived vWFs. Whole blood ristocetin-induced platelet aggregation (RIPA), plasma ristocetin cofactor activity (RCo), and thrombin generation were compared between ECMO patient blood samples and control blood samples and between vWF-treated ECMO patient blood samples and nontreated samples. RESULTS: ECMO patient blood samples had severely reduced median RIPA compared to control samples 2 ohms (1-12 [25th-75th percentile]) vs 20 ohms (11-42) (P < .001). Treatment of ECMO patient blood samples with high-dose recombinant vWF significantly increased median RIPA to 10 ohms (2-15) (P < .001), while low-dose recombinant vWF and low- and high-dose plasma-derived vWFs did not significantly increase RIPA; 6 ohms (3-14), 4 ohms (1-13), and 6 ohms (2-10), respectively (P = .25, >.99, and >.99). Treatment with high-dose recombinant vWF and low- and high-dose plasma-derived vWFs significantly increased median plasma RCo to 4.7 international units (IU)/mL (3.7-5.9), 3.3 IU/mL (2.7-4.8), and 3.9 IU/mL (3.4-5.3), respectively, compared to controls 1.8 IU/mL (1.5-2.3) (all P < .001). Treatment with low- and high-dose plasma-derived vWFs significantly increased mean endogenous thrombin potential (6270.2 ± 2038.7 and 6313.1 ± 1913.3) compared to nontreated samples (5856.7 ± 1924.6) (P = .04 and .006), whereas treatment with low- and high-dose recombinant vWFs had no significant effect on mean endogenous thrombin potential (5776.1 ± 2087.3 and 5856.2 ± 1946.4) (P > .99 for both comparisons). CONCLUSIONS: In vitro treatment of ECMO patient blood samples with high-dose recombinant vWF was superior to low-dose recombinant vWF and plasma-derived vWF in terms of improving RIPA. In addition, recombinant vWF treatment did not increase endogenous thrombin potential, which may reduce overall thrombotic risk if it used to treat acquired von Willebrand syndrome in ECMO patients.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Factor VIII/administración & dosificación , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/terapia , Factor de von Willebrand/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Factor VIII/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Plasma , Proteínas Recombinantes/administración & dosificación , Proteínas Recombinantes/sangre , Resultado del Tratamiento , Factor de von Willebrand/metabolismo
5.
Hematology Am Soc Hematol Educ Program ; 2021(1): 552-558, 2021 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-34889419

RESUMEN

Pregnancy and childbirth pose an important hemostatic challenge for women with von Willebrand disease (VWD) and can be associated with an increased risk of maternal and neonatal bleeding complications. VWD is a genetically and clinically heterogeneous bleeding disorder caused by a deficiency or an abnormality in the function of von Willebrand factor. Understanding inheritance pattern, hemostatic response to pregnancy, and response to treatment is essential for provision of individualized obstetric care and optimal outcome. A multidisciplinary approach to management with a close liaison between the obstetric team and the hemophilia treatment center is required for continuity of care from preconception counseling through to antenatal, peripartum, and postpartum care. Delivery plan must be coordinated by the multidisciplinary team and include decisions on place and mode of delivery, implementation of safe analgesia/anesthesia, and peripartum hemostasis. In this clinical case-based review, we aim to deliver evidence-based practical guidance for challenges encountered during pregnancy and management of childbirth and puerperium.


Asunto(s)
Complicaciones Hematológicas del Embarazo/terapia , Enfermedades de von Willebrand/terapia , Adulto , Parto Obstétrico , Manejo de la Enfermedad , Femenino , Humanos , Embarazo , Complicaciones Hematológicas del Embarazo/sangre , Complicaciones Hematológicas del Embarazo/diagnóstico , Resultado del Embarazo , Adulto Joven , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico
6.
PLoS One ; 16(4): e0249402, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33844690

RESUMEN

INTRODUCTION: The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simulates plug formation under high shear flow. The PFA-100 measures the time required to occlude the aperture in a biochemically active cartridge and is expressed in a term of closure time (CT). In Algeria, the reference values used in clinical laboratories are of Western origin. However, ethnic, genetic, dietary environmental, and diet differences between populations may affect reference intervals. We established the reference intervals of PFA-100 closure times in healthy Algerian adults according to the International Federation of Clinical Chemistry method, and we compared them with those of Western and Asian countries. MATERIAL AND METHODS: We enrolled 303 healthy blood donors in the study. 218 subjects met inclusion criteria. We analyzed the blood sample on the PFA-100 for CT with both the collagen epinephrine and collagen ADP cartridges. RESULTS: The reference intervals of PFA-100 collagen epinephrine CT and PFA-100 collagen ADP CT were 91-207 seconds and 71-144 seconds, respectively. Compared to Western and Asian populations, there were significant differences. The upper limits of CTs were higher for Algerians in this study. Our findings show that many healthy Algerians would be incorrectly identified as having a primary hemostasis abnormality according to the reference intervals of the manufacturer and scientific literature. CONCLUSION: This report provides the first reference intervals for PFA-100 CTs in healthy Algerian adults. These results improve the accuracy of diagnosis and patient care in Algeria.


Asunto(s)
Pruebas de Función Plaquetaria/normas , Adulto , Argelia , Femenino , Hemostasis , Humanos , Masculino , Sistemas de Atención de Punto , Valores de Referencia , Factores de Tiempo , Enfermedades de von Willebrand/sangre
7.
Anesth Analg ; 133(5): 1244-1250, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33913917

RESUMEN

BACKGROUND: Although Von Willebrand disease (vWD) is the most common heritable bleeding disorder, there are limited reports regarding the safety of neuraxial anesthesia in the obstetric population and no definitive guidelines specifying recommended pretreatment or therapies for patients with vWD. The aim of this study is to describe the anesthetic management of pregnant patients with vWD at a large tertiary-care center. METHODS: In this retrospective analysis, the study population was identified from vWD patients evaluated by our high-risk obstetric anesthesia consultation service and by diagnosis codes from our institutional research database registry. We manually reviewed records of patients with vWD in pregnancy who delivered at our institution between January 1, 2000 and January 1, 2019 for demographic characteristics, circumstances of vWD diagnosis, history of bleeding, laboratory studies, and overall management of vWD. Anesthetic management of vWD was at the discretion of individual providers, based on multidisciplinary consensus and the specific circumstances of each patient's disease and obstetric presentation. RESULTS: We identified 106 deliveries among 71 individual vWD patients. Of the unique patients, 54 had vWD type 1, 6 had vWD type 2, and 11 had vWD type unknown. Forty-three cases (40.6%) were cesarean deliveries. Neuraxial techniques were used in 94 of 106 deliveries (88.7%). Treatment with desmopressin or Von Willebrand factor/factor VIII concentrate before neuraxial anesthesia occurred in 27 of 94 neuraxial anesthetics (28.7%). Eleven deliveries (10.4%) were complicated by postpartum hemorrhage (PPH), defined as estimated blood loss of ≥1000 mL. There were no noted adverse anesthetic outcomes (0 of 106; 0% [95% confidence interval, 0-3.4]), including neuraxial hematoma or thromboembolic events. CONCLUSIONS: In this large case series, the majority of vWD patients received neuraxial anesthesia for labor and delivery, with no noted adverse events. This suggests that neuraxial anesthesia can be safely performed with the peripartum management that we describe. Pretreatment was dictated by the type and severity of vWD. Multidisciplinary planning is important to optimize the coagulation status of patients with vWD and facilitate options for analgesia and anesthesia.


Asunto(s)
Anestesia Obstétrica , Cesárea , Complicaciones Hematológicas del Embarazo , Enfermedades de von Willebrand/complicaciones , Adulto , Anestesia Obstétrica/efectos adversos , Cesárea/efectos adversos , Bases de Datos Factuales , Femenino , Humanos , Embarazo , Complicaciones Hematológicas del Embarazo/sangre , Complicaciones Hematológicas del Embarazo/diagnóstico , Complicaciones Hematológicas del Embarazo/terapia , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/terapia
8.
Hematology ; 26(1): 301-304, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33663351

RESUMEN

BACKGROUND: Acquired von Willebrand syndrome (AVWS) is a rare, frequently underdiagnosed and underestimated bleeding disorder. Careful personal and family history and late-onset mucocutaneous bleeding could help clarify the etiology of bleeding deficiency. CASE PRESENTATION: An 82-year-old male patient was admitted to our clinic with a severe nosebleed on 30.05.2018. Laboratory results revealed thrombocytosis, elevated white blood cell count and high LDH. Basic coagulation parameters were normal. He was referred to our clinic, where a bone marrow biopsy was taken. His personal and family history had no mention of bleeding disorders, nor was he on anticoagulant therapy. We detected elevated VWF antigen and decreased VWF ristocetin cofactor activity. Loss of high molecular weight multimers was detected by using agarose gel electrophoresis. These laboratory results were indicative of AVWS. Hydroxyurea treatment was initiated, leading to a gradual decrease in platelet count. The histological examination revealed essential thrombocytosist while mutation analysis was JAK2/CALR/MPL negative. However, due to severe nosebleeds, the patient was hospitalized and needed blood transfusion. A cardiological check-up revealed the progression of aortic valve stenosis. After, balloon-dilation a transcatheter aortic valve implantation was performed. As a result, VWF activity and activity to antigen ratio returned to normal as did multimeric structure. In July 2019, the follow-up examination showed that the patient was in a satisfactory condition, with normal hematological parameters, and no new nosebleed episode occurred. CONCLUSIONS: The patient complained of recurring nosebleeds, which stopped completely after the resolution of both underlying conditions successful cytoreductive treatment of triple-negative ET and transcatheteric aortic valve replacement.


Asunto(s)
Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/terapia , Factor de von Willebrand/análisis , Anciano de 80 o más Años , Transfusión Sanguínea , Inhibidores Enzimáticos/uso terapéutico , Hemorragia/sangre , Hemorragia/complicaciones , Hemorragia/terapia , Humanos , Hidroxiurea/uso terapéutico , Masculino , Trombocitosis/sangre , Trombocitosis/complicaciones , Trombocitosis/terapia , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/complicaciones
9.
J Pediatr Hematol Oncol ; 43(3): 101-103, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33560075

RESUMEN

Hemolacria is a rare condition that causes a person to produce tears that are partially composed of blood. It can be a presenting feature of certain ocular and systemic conditions. Here, the authors describe an interesting case of a 12-year-old boy with an underlying beta-thalassemia trait, who presented with a 2-day history of bilateral blood-stained tears, and an episode of epistaxis. Ocular examination was normal, and syringing showed no nasolacrimal duct blockage. Systemic examination was unremarkable. Laboratory investigations confirmed type 2 von Willebrand disease. Management of hemolacria remains a clinical challenge given the rare occurrence of the disease. In this case report, the authors discuss the differential diagnosis and management approach to hemolacria.


Asunto(s)
Lágrimas , Enfermedades de von Willebrand/diagnóstico , Niño , Epistaxis/sangre , Epistaxis/complicaciones , Epistaxis/diagnóstico , Humanos , Masculino , Enfermedades Raras/sangre , Enfermedades Raras/complicaciones , Enfermedades Raras/diagnóstico , Lágrimas/química , Talasemia beta/sangre , Talasemia beta/complicaciones , Talasemia beta/diagnóstico , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/complicaciones
10.
Clin Appl Thromb Hemost ; 27: 1076029620984546, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33448867

RESUMEN

In patients with von Willebrand disease (vWD) the interest in age-related comorbidities has grown, because the life expectancy of these patients has increased. The research question of this study was whether patients with vWD show a different endothelial function compared to the general population. A total of 37 patients with type 1 (n = 23), type 2 (n = 10) and type 3 (n = 4) vWD, 14 controls and 38 patients with coronary artery disease (CAD) were included in this study. Five markers of endothelial dysfunction (MOED) were determined. Moreover, the endothelial function was examined using the Itamar Endo-PAT. The reactive hyperemia index (RHI) was calculated from the results. The markers soluble intercellular adhesion molecule-1 (p = 0.171), P-Selectin (p = 0.512), interleukin-6 (p = 0.734) and monocyte chemoattractant protein-1 (p = 0.761) showed higher levels in patients with vWD, but were not significantly different compared to the control group. RHI was impaired in CAD-patients (1.855), whereas vWD patients had mean results of 1.870 and controls 2.112 (p = 0.367). In this study, the endothelial function measurements of patients with von Willebrand disease were not significantly different compared to healthy controls.


Asunto(s)
Endotelio Vascular/fisiopatología , Enfermedades de von Willebrand/fisiopatología , Adulto , Biomarcadores/sangre , Estudios de Casos y Controles , Quimiocina CCL2/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Hiperemia/sangre , Hiperemia/fisiopatología , Molécula 1 de Adhesión Intercelular/sangre , Interleucina-6/sangre , Masculino , Persona de Mediana Edad , Selectina-P/sangre , Enfermedad de von Willebrand Tipo 1/sangre , Enfermedad de von Willebrand Tipo 1/fisiopatología , Enfermedad de von Willebrand Tipo 2/sangre , Enfermedad de von Willebrand Tipo 2/fisiopatología , Enfermedad de von Willebrand Tipo 3/sangre , Enfermedad de von Willebrand Tipo 3/fisiopatología , Enfermedades de von Willebrand/sangre
11.
Blood Cells Mol Dis ; 87: 102530, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33341070

RESUMEN

BACKGROUND: Severe von Willebrand disease (VWD) may be associated with chronic joint damage and may require prophylactic therapy. Emicizumab is a humanized bispecific antibody, which mimics the function of coagulation factor VIII (FVIII), and it has been approved for prophylaxis in hemophilia A. METHODS: This is the first study assessing the potential future role of emicizumab as an alternative prophylactic treatment in patients with severe VWD, based upon a thrombin generation (TG) ex vivo analysis. We report 51 weeks of successful off label emicizumab prophylaxis in a child with severe VWD and recurrent hemarthroses and progressive arthropathy despite adherence to previous prophylaxis with replacement therapy. RESULTS AND CONCLUSIONS: Our work demonstrated that ex vivo spiking with emicizumab increased TG in plasma from patients with type 3 VWD. Similar TG results were observed in our treated patient, whose therapy was well tolerated without any adverse events. Both in vitro and ex vivo TG data support sufficient hemostasis without exceeding the range seen in healthy volunteers. Further collaborative studies on the efficacy and safety of emicizumab prophylaxis in severe VWD is warranted.


Asunto(s)
Anticuerpos Biespecíficos/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Enfermedades de von Willebrand/tratamiento farmacológico , Adolescente , Adulto , Anticuerpos Biespecíficos/administración & dosificación , Anticuerpos Monoclonales Humanizados/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Niño , Femenino , Hemartrosis/sangre , Hemartrosis/tratamiento farmacológico , Hemostasis/efectos de los fármacos , Humanos , Masculino , Trombina/análisis , Adulto Joven , Enfermedades de von Willebrand/sangre
12.
Ann Thorac Surg ; 112(4): 1257-1264, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33227272

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) cause degradation of von Willebrand factor (VWF) multimers and bleeding. Multiple techniques exist to characterize VWF deficiency. However, a standard methodology has not been established in LVAD patients. Toward this goal, we evaluated 4 methods to quantify VWF multimers. METHODS: We collected paired blood samples from patients (n = 48) before and after 1 week of LVAD support. After 652 ± 59 days of support, patients were classified as bleeders (≥1 bleeding episode) or nonbleeders. VWF multimers were resolved with electrophoresis and immunoblotting, the gold-standard to evaluate VWF multimers. We evaluated 4 quantification methods. RESULTS: Each method demonstrated significant VWF degradation during LVAD support vs a paired, pre-LVAD sample (method 1, VWF length: 48 of 48 patients, -10% ± 1%, P < .0001; method 2, VWF density: 40 of 48, -34% (interquartile range, -46% to -8%), P < .0001; method 3, pre-LVAD to LVAD ratio: 46 of 48, 17 ± 5: 10 ± 1, P < .0001; method 4, LVAD/pre-LVAD index: 46 of 48, 57% (interquartile range, 50% to 73%), P < .0001). Bleeding occurred in 27 of 48 patients. Method 1 demonstrated significantly fewer VWF multimers in bleeders compared with nonbleeders (-11% ± 1% vs -8% ± 1%; P = .01). Other methods did not demonstrate this potentially important clinical relationship. CONCLUSIONS: A standardized methodology is needed to quantify VWF multimer degradation with mechanical circulatory support devices. Novel method 1 successfully quantified the patient-specific change in VWF multimer length during LVAD support and demonstrated a difference in VWF multimers between bleeders and nonbleeders. Adoption of consensus methodology will assist to standardize patient-specific bleeding risk, inform anticoagulation and antiplatelet therapy, and evaluate LVAD hemocompatibility.


Asunto(s)
Corazón Auxiliar/normas , Complicaciones Posoperatorias/sangre , Enfermedades de von Willebrand/sangre , Factor de von Willebrand/análisis , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
13.
Hematology Am Soc Hematol Educ Program ; 2020(1): 547-552, 2020 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-33275722

RESUMEN

Women with bleeding disorders suffer from multiple bleeding symptoms, including easy bruising, epistaxis, bleeding from minor wounds and the oral cavity, and bleeding after dental work or surgery. However, women with bleeding disorders especially suffer from gynecologic and obstetrical bleeding. These symptoms often are not recognized as abnormal, and many women are left undiagnosed and without access to appropriate medical care. Additional challenges to diagnosing women with bleeding disorders include lack of access to appropriate laboratory testing and issues around disease classification and nomenclature. Efforts have been undertaken to address these challenges, including the development and validation of bleeding assessment tools and strategies to clarify diagnostic thresholds and algorithms for von Willebrand disease (VWD) and platelet function disorders. Efforts to improve communication with the nomenclature used for hemophilia carriers are also underway.


Asunto(s)
Algoritmos , Accesibilidad a los Servicios de Salud , Hemorragia , Servicios de Salud para Mujeres , Enfermedades de von Willebrand , Adolescente , Femenino , Hemorragia/sangre , Hemorragia/diagnóstico , Hemorragia/terapia , Humanos , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/terapia
14.
Blood Coagul Fibrinolysis ; 31(6): 382-386, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32815913

RESUMEN

: The defect function of the von Willebrand factor (VWF) in carrying factor VIII (FVIII) leads to von Willebrand disease type 2N (VWD 2N) which could be easily misdiagnosed as hemophilia A. Differentiating of VWD 2N from hemophilia A is crucial for patient treatment and genetic counseling. As a retrospective study, we aimed to evaluate the current diagnostic work-up of Iranian patients with mild/moderate deficiency of FVIII levels and the possibility of misdiagnosis of VWD 2N as hemophilia A. All patients who referred to the reference coagulation laboratory at the Iranian Blood Transfusion Organization in a 10-months period for bleeding diathesis work-up with the request of FVIII activity level were included. Clinical and laboratory phenotypes including International Society on Thrombosis and Hemostasis - Bleeding Assessment Tool, FVIII activity, VWF antigen, VWF ristocetin cofactor, and FVIII binding capacity of VWF were assessed on suspected cases for VWD 2N. In total, the results of 896 patients for investigation of VWD 2N were evaluated and five new patients were identified within unrelated families with abnormal VWF:FVIIIB levels. Four were heterozygous for VWD 2N and one homozygous whom all were misdiagnosed as hemophilia A and underwent inappropriate treatments. The median bleeding score of the VWD 2N population was nine (4-13). In Iran, probably a significant number of VWD 2N patients are misdiagnosed as hemophilia A due to insufficient test panel for subtyping of von Willebrand disease. This study also emphasized the need for inclusion of the VWF:FVIIIB in suspected hemophilia A to achieve an optimal treatment strategy.


Asunto(s)
Enfermedad de von Willebrand Tipo 2/diagnóstico , Enfermedades de von Willebrand/diagnóstico , Adolescente , Adulto , Niño , Preescolar , Diagnóstico Diferencial , Manejo de la Enfermedad , Femenino , Hemofilia A , Hemorragia/sangre , Hemorragia/diagnóstico , Hemorragia/epidemiología , Hemorragia/terapia , Hemostasis , Humanos , Lactante , Irán/epidemiología , Masculino , Persona de Mediana Edad , Adulto Joven , Enfermedad de von Willebrand Tipo 2/sangre , Enfermedad de von Willebrand Tipo 2/epidemiología , Enfermedad de von Willebrand Tipo 2/terapia , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/epidemiología , Enfermedades de von Willebrand/terapia
15.
Arterioscler Thromb Vasc Biol ; 40(9): 2187-2194, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32640909

RESUMEN

OBJECTIVE: Aortic stenosis may be complicated by an acquired von Willebrand syndrome that rarely causes significant bleeding, raising the question of why it does so in a few cases. To seek an explanation, we studied 5 severe bleeder aortic stenosis patients in a cohort of 49 patients, using the flowchart for inherited von Willebrand disease. Approach and Results: All 5 patients were lacking in large and intermediate VWF (von Willebrand factor) multimers, 3 had reduced plasma and platelet VWF levels, and none showed PFA100 closure. Two patients (those with most multimers missing) also had a short VWF half-life. Genetic analyses on the 3 patients with reduced platelet VWF levels revealed that one carried both the c.1164C>G and the c.7880G>A mutations, and another carried the c.3390C>T mutation, while the third had one of the 2 VWF alleles relatively less expressed than the other (25% versus 75%). No genetic alterations emerged in the other 2 patients. Successful replacement of the stenotic aortic valve, performed in the 2 patients with VWF mutations, did not correct their abnormal VWF multimer picture-unlike what happened in the aortic stenosis patients without bleeding symptoms. CONCLUSIONS: Our findings suggest that acquired von Willebrand syndrome can develop in patients with hitherto-undiagnosed inherited von Willebrand disease. Since von Willebrand disease is the most common bleeding disorder, this possibility should be considered in aortic stenosis patients-especially those with a more severe bleeding history and more disrupted VWF laboratory patterns-because they risk hemorrhage during aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Hemostasis , Hemorragia Posoperatoria/etiología , Enfermedades de von Willebrand/complicaciones , Factor de von Willebrand/metabolismo , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Biomarcadores/sangre , Estudios de Casos y Controles , Femenino , Predisposición Genética a la Enfermedad , Semivida , Hemostasis/genética , Humanos , Masculino , Mutación , Fenotipo , Hemorragia Posoperatoria/sangre , Hemorragia Posoperatoria/diagnóstico , Valor Predictivo de las Pruebas , Multimerización de Proteína , Estabilidad Proteica , Proteolisis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/genética , Factor de von Willebrand/genética
17.
Thromb Haemost ; 120(8): 1159-1165, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32629500

RESUMEN

von Willebrand disease (VWD) is a quantitative or qualitative defect in von Willebrand factor (VWF) resulting in mucocutaneous bleeding symptoms and hemorrhage following hemostatic challenges, such as trauma or surgery. VWD-specific therapy, DDAVP (1-desamino-8-D-arginine vasopressin) and VWF concentrates, is necessary periprocedurally to ensure adequate hemostasis. The aging VWD patient may complicate this matter. The plasma concentration of many coagulation proteins, including VWF, increases with age. While it has been established that VWF levels increase with age in a healthy population, emerging research demonstrates this occurs in certain subtypes of VWD, too. Thus, the management of periprocedural VWD-specific therapy in the aging VWD patient is problematic when VWF levels increase over time to normal, and hematologists are left with uncertainty regarding whether or not periprocedural VWD-specific therapy is still necessary. In this article, we will review the current state of the literature regarding the effect of age on VWF levels in the healthy population and VWD while exploring possible etiologies for this phenomenon. Further, we will detail how this affects bleeding symptoms and highlight what research remains to be done to optimize care in this patient population.


Asunto(s)
Envejecimiento/sangre , Hemorragia/etiología , Enfermedades de von Willebrand/sangre , Factor de von Willebrand/análisis , Anciano , Factores de Coagulación Sanguínea/análisis , Desamino Arginina Vasopresina/uso terapéutico , Diverticulitis/complicaciones , Diverticulitis/cirugía , Femenino , Humanos , Cuidados Preoperatorios , Enfermedades de von Willebrand/complicaciones , Enfermedades de von Willebrand/tratamiento farmacológico , Factor de von Willebrand/uso terapéutico
18.
Eur J Haematol ; 105(4): 365-377, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32496614

RESUMEN

von Willebrand disease (VWD) is the most common inherited bleeding disorder characterised by a quantitative or qualitative deficiency in von Willebrand factor (VWF). During invasive surgical procedures, patients with VWD require additional treatment to maintain haemostasis; however, due to the complexity of VWD, there is a lack of consensus on the optimal management. In the perioperative period, patients are usually treated with VWF and factor FVIII (FVIII)-containing concentrates to provide an immediate haemostatic response to prevent excessive bleeding during both elective and emergency surgery. With the introduction of recombinant VWF (rVWF), there is a need for guidance on the use of the various VWF products in the perioperative period for all types of patients and surgeries. This review provides an overview of the current evidence for the surgical management of patients with VWD and, summarises the optimal treatment approach during the perioperative period, and highlights key unanswered questions and the research needed to address the evidence gaps.


Asunto(s)
Atención Perioperativa , Enfermedades de von Willebrand/terapia , Biomarcadores , Coagulación Sanguínea , Toma de Decisiones Clínicas , Desamino Arginina Vasopresina/administración & dosificación , Manejo de la Enfermedad , Susceptibilidad a Enfermedades , Humanos , Atención Perioperativa/métodos , Índice de Severidad de la Enfermedad , Tromboembolia/diagnóstico , Tromboembolia/etiología , Tromboembolia/prevención & control , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico , Enfermedades de von Willebrand/etiología , Factor de von Willebrand/administración & dosificación , Factor de von Willebrand/genética
19.
Thromb Haemost ; 120(5): 793-804, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32369850

RESUMEN

BACKGROUND: Accurate diagnosis of symptomatic low von Willebrand factor (VWF) remains a major challenge in von Willebrand disease (VWD). However, present tests do not adequately take into account flow forces that, at very high shear rates, reveal a weakness in the VWF-platelet glycoprotein glycoprotein Ib bond in normal subjects. The degree of this weakness is greater in symptomatic, but not asymptomatic, low VWF. OBJECTIVE: The aim of this study is to distinguish patients with symptomatic low VWF (levels in the 30-50 IU/dL range) from those with asymptomatic low VWF and normal subjects. METHODS: We measured platelet adhesion (PA)/aggregation in our novel microfluidic flow system that permits real-time assessment of PA (surface coverage) and PA/aggregation (V, aggregate volume) using epifluorescence digital videomicroscopy in flowing noncitrated whole blood at 4,000 second-1. Blood samples from 24 low VWF patients and 15 normal subjects were collected into plastic tubes containing 4 U/mL enoxaparin. MetaMorph software was used to quantify rates of PA and V increase. RESULTS: Rates of PA increase showed a bimodal distribution, with values for 16/24 patients (Group I) all below the 2.5th percentile of normal, and values for 8/24 patients (Group II) similar to controls. Bleeding scores (mean ± standard error) were 5.50 ± 0.45 versus 2.75 ± 0.45 (p = 0.00077), and 10 clinically significant bleeding events were observed in seven versus zero (p = 0.0295) Group I and Group II subjects, respectively. CONCLUSION: The present approach may offer a definitive means to distinguish symptomatic low VWF from either asymptomatic low VWF or normal controls.


Asunto(s)
Adhesividad Plaquetaria , Agregación Plaquetaria , Pruebas de Función Plaquetaria , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand/metabolismo , Adolescente , Adulto , Enfermedades Asintomáticas , Biomarcadores/sangre , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Técnicas Analíticas Microfluídicas , Microscopía por Video , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estrés Mecánico , Factores de Tiempo , Adulto Joven , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/complicaciones
20.
Am J Hematol ; 95(9): 1022-1029, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32419248

RESUMEN

Increased awareness of von Willebrand Disease (VWD) has led to more frequent diagnostic laboratory testing, which insurers often dictate be performed at a facility with off-site laboratory processing, instead of a coagulation facility with onsite processing. Off-site processing is more prone to preanalytical variables causing falsely low levels of von Willebrand Factor (VWF) due to the additional transport required. Our aim was to determine the percentage of discordance between off-site and onsite specimen processing for VWD in this multicenter, retrospective study. We enrolled females aged 12 to 50 years who had off-site specimen processing for VWF assays, and repeat testing performed at a consulting institution with onsite coagulation phlebotomy and processing. A total of 263 females from 17 institutions were included in the analysis. There were 251 subjects with both off-site and onsite VWF antigen (VWF:Ag) processing with 96 (38%) being low off-site and 56 (22%) low onsite; 223 subjects had VWF ristocetin co-factor (VWF:RCo), 122 (55%) were low off-site and 71 (32%) were low onsite. Similarly, 229 subjects had a Factor VIII (FVIII) assay, and 67 (29%) were low off-site with less than half, 29 (13%) confirmed low with onsite processing. Higher proportions of patients demonstrated low VWF:Ag, VWF:RCo, and/or FVIII with off-site processing compared to onsite (McNemar's test P-value <.0005, for all assays). These results emphasize the need to decrease delays from sample procurement to processing for VWF assays. The VWF assays should ideally be collected and processed at the same site under the guidance of a hematologist.


Asunto(s)
Errores Diagnósticos , Enfermedades de von Willebrand , Factor de von Willebrand/metabolismo , Adolescente , Adulto , Niño , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Enfermedades de von Willebrand/sangre , Enfermedades de von Willebrand/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA