Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.755
Filtrar
1.
Arq Gastroenterol ; 61: e24022, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39046006

RESUMEN

BACKGROUND: The current definition for hypercontractile esophagus was arbitrarily set at the uppermost range in volunteers for a specific equipment. OBJECTIVE: This study aims to critically analyze the concept of hypercontractile waves to redefine hypercontractile esophagus parameters. METHODS: We reviewed 500 unselected and consecutive HRM tests (5000 waves) performed in a water -perfused system. RESULTS: Mean distal contractility integral (DCI) was 825±1492 (0-42775) mmHg.cm.s, two standard deviations above average = 3810; 95th percentile = 2798 mmHg.cm.s. CONCLUSION: In healthy volunteers, two standard deviations above average is 4000 mmHg.cm.s, we thus suggest this value to define hypercontractile waves and define hypercontractile esophagus in a water-perfused HRM system.


Asunto(s)
Trastornos de la Motilidad Esofágica , Manometría , Humanos , Masculino , Manometría/métodos , Femenino , Adulto , Trastornos de la Motilidad Esofágica/fisiopatología , Trastornos de la Motilidad Esofágica/diagnóstico , Persona de Mediana Edad , Esófago/fisiopatología , Esófago/fisiología , Adulto Joven , Anciano , Contracción Muscular/fisiología , Valores de Referencia
2.
Am J Physiol Gastrointest Liver Physiol ; 327(3): G405-G413, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38953836

RESUMEN

Our prior study reveals that the distension-contraction profiles using high-resolution manometry impedance recordings can distinguish patients with dysphagia symptom but normal esophageal function testing ("functional dysphagia") from control subjects. The aim of this study was to determine the diagnostic value of the recording protocol used in our prior studies (10-mL swallows with subjects in the Trendelenburg position) against the standard clinical protocol (5-mL swallows with subjects in the supine position). We used advanced machine learning techniques and robust metrics for classification purposes. Studies were performed on 30 healthy subjects and 30 patients with functional dysphagia. A custom-built software was used to extract the relevant distension-contraction features of esophageal peristalsis. Ensemble methods, i.e., gradient boost, support vector machines (SVMs), and logit boost, were used as the primary machine learning algorithms. Although the individual contraction features were marginally different between the two groups, the distension features of peristalsis were significantly different. The receiver operating characteristic (ROC) curve values for the standard recording protocol and the distension features ranged from 0.74 to 0.82; they were significantly better for the protocol used in our prior studies, ranging from 0.81 to 0.91. The ROC curve values using three machine learning algorithms were far superior for the distension than the contraction features of esophageal peristalsis, revealing a value of 0.95 for the SVM algorithm. Current patient classification for esophageal motility disorders, based on the contraction phase of peristalsis, ignores a large number of patients who have an abnormality in the distension phase of peristalsis. Distension-contraction plots should be the standard for assessing esophageal peristalsis in clinical practice.NEW & NOTEWORTHY Our findings underscore the superiority of distension features over contraction metrics in diagnosing esophageal dysfunctions. By leveraging state-of-the-art machine learning techniques, our study highlights the diagnostic potential of distension-contraction plots of peristalsis. Implementation of these plots could significantly enhance the accuracy of identifying patients with esophageal motor disorders, advocating for their adoption as the standard in clinical practice.


Asunto(s)
Trastornos de Deglución , Deglución , Esófago , Manometría , Peristaltismo , Humanos , Manometría/métodos , Peristaltismo/fisiología , Masculino , Femenino , Esófago/fisiología , Esófago/fisiopatología , Persona de Mediana Edad , Adulto , Trastornos de Deglución/diagnóstico , Trastornos de Deglución/fisiopatología , Deglución/fisiología , Anciano , Inteligencia Artificial , Trastornos de la Motilidad Esofágica/diagnóstico , Trastornos de la Motilidad Esofágica/fisiopatología , Aprendizaje Automático , Contracción Muscular/fisiología
3.
Anesthesiology ; 141(3): 541-553, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38753985

RESUMEN

BACKGROUND: Patient-ventilator dyssynchrony is frequently observed during assisted mechanical ventilation. However, the effects of expiratory muscle contraction on patient-ventilator interaction are underexplored. The authors hypothesized that active expiration would affect patient-ventilator interaction and they tested their hypothesis in a mixed cohort of invasively ventilated patients with spontaneous breathing activity. METHODS: This is a retrospective observational study involving patients on assisted mechanical ventilation who had their esophageal pressure (Peso) and gastric pressure monitored for clinical purposes. Active expiration was defined as gastric pressure rise (ΔPgas) greater than or equal to 1.0 cm H2O during expiratory flow without a corresponding change in diaphragmatic pressure. Waveforms of Peso, gastric pressure, diaphragmatic pressure, flow, and airway pressure (Paw) were analyzed to identify and characterize abnormal patient-ventilator interaction. RESULTS: 76 patients were identified with Peso and gastric pressure recordings, of whom 58 demonstrated active expiration with a median ΔPgas of 3.4 cm H2O (interquartile range = 2.4 to 5.3) observed in this subgroup. Among these 58 patients, 23 presented the following events associated with expiratory muscle activity: (1) distortions in Paw and flow that resembled ineffective efforts, (2) distortions similar to autotriggering, (3) multiple triggering, (4) prolonged ventilatory cycles with biphasic inspiratory flow, with a median percentage (interquartile range) increase in mechanical inflation time and tidal volume of 54% (44 to 70%) and 25% (8 to 35%), respectively and (5) breathing exclusively by expiratory muscle relaxation. Gastric pressure monitoring was required to identify the association of active expiration with these events. Respiratory drive, assessed by the rate of inspiratory Peso decrease, was significantly higher in patients with active expiration (median [interquartile range] dPeso/dt: 12.7 [9.0 to 18.5] vs 9.2 [6.8 to 14.2] cmH2O/sec; P < 0.05). CONCLUSIONS: Active expiration can impair patient-ventilator interaction in critically ill patients. Without documenting gastric pressure, abnormal patient-ventilator interaction associated with expiratory muscle contraction may be mistakenly attributed to a mismatch between the patient's inspiratory effort and mechanical inflation. This misinterpretation could potentially influence decisions regarding clinical management.


Asunto(s)
Espiración , Respiración Artificial , Estómago , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Espiración/fisiología , Anciano , Estómago/fisiología , Respiración Artificial/métodos , Monitoreo Fisiológico/métodos , Presión , Esófago/fisiología , Esófago/fisiopatología
4.
J R Soc Interface ; 21(213): 20230592, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593841

RESUMEN

The mechanical characterization of the oesophagus is essential for applications such as medical device design, surgical simulations and tissue engineering, as well as for investigating the organ's pathophysiology. However, the material response of the oesophagus has not been established ex vivo in regard to the more complex aspects of its mechanical behaviour using fresh, human tissue: as of yet, in the literature, only the hyperelastic response of the intact wall has been studied. Therefore, in this study, the layer-dependent, anisotropic, visco-hyperelastic behaviour of the human oesophagus was investigated through various mechanical tests. For this, cyclic tests, with increasing stretch levels, were conducted on the layers of the human oesophagus in the longitudinal and circumferential directions and at two different strain rates. Additionally, stress-relaxation tests on the oesophageal layers were carried out in both directions. Overall, the results show discrete properties in each layer and direction, highlighting the importance of treating the oesophagus as a multi-layered composite material with direction-dependent behaviour. Previously, the authors conducted layer-dependent cyclic experimentation on formalin-embalmed human oesophagi. A comparison between the fresh and embalmed tissue response was carried out and revealed surprising similarities in terms of anisotropy, strain-rate dependency, stress-softening and hysteresis, with the main difference between the two preservation states being the magnitude of these properties. As formalin fixation is known to notably affect the formation of cross-links between the collagen of biological materials, the differences may reveal the influence of cross-links on the mechanical behaviour of soft tissues.


Asunto(s)
Esófago , Proyectos de Investigación , Humanos , Estrés Mecánico , Esófago/fisiología , Anisotropía , Fenómenos Biomecánicos , Resistencia a la Tracción
5.
Sci Rep ; 14(1): 9771, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684823

RESUMEN

Transpulmonary pressure can be estimated using esophageal balloon (EB) catheters, which come in a variety of manufacturing configurations. We assessed the performance of novel polyurethane EB designs, Aspisafe NG and NG+, against existing alternatives. We created a biomechanical model of the chest cavity using a plastic chamber and an ex-vivo porcine esophagus. The chamber was pressurized (- 20 and + 20 cmH2O) to simulate pleural pressures. We conducted tests with various EB inflation volumes and measured transesophageal pressure (TEP). TEP measurement was defined as accurate when the difference between pressure within the EB and chamber was 0 ± 1 cmH2O. We computed the minimal (Vaccuracy-min) and maximal (Vaccuracy-max) EB inflation volumes of accuracy. Inflation volumes were further validated using a surrogate method derived by the clinically validated positive pressure occlusion test (PPOT). When the esophageal balloons were filled with inflation volumes within the range provided by the manufacturers, the accuracy of TEP measurements was marginal. Our tests found median Vaccuracy-min across EB of 0.00-0.50 mL (p = 0.130), whereas Vaccuracy-max ranged 0.50-2.25 mL (p = 0.002). Post PPOT validation, median TEP was - 0.4 cmH2O (- 1.5 to 0.3) (p < 0.001 among catheters). The Aspisafe NG and NG+ were accurate in 81.7% and 77.8% of the measurements, respectively. We characterized two new EBs, which demonstrated good benchtop accuracy in TEP measurements. However, accuracy was notably influenced by the precise selection of EB inflation volumes.


Asunto(s)
Catéteres , Esófago , Presión , Cavidad Torácica , Animales , Esófago/fisiología , Porcinos , Fenómenos Biomecánicos , Poliuretanos/química , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
6.
J Physiol Sci ; 74(1): 26, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654149

RESUMEN

Purines such as ATP are regulatory transmitters in motility of the gastrointestinal tract. The aims of this study were to propose functional roles of purinergic regulation of esophageal motility. An isolated segment of the rat esophagus was placed in an organ bath, and mechanical responses were recorded using a force transducer. Exogenous application of ATP (10-100 µM) evoked relaxation of the esophageal smooth muscle in a longitudinal direction under the condition of carbachol (1 µM) -induced precontraction. Pretreatment with a non-selective P2 receptor antagonist, suramin (500 µM), and a P2Y receptor antagonist, cibacron blue F3GA (200 µM), inhibited the ATP (100 µM) -induced relaxation, but a P2X receptor antagonist, pyridoxal phosphate-6-azophenyl-2,4-disulfonic acid (50 µM), did not affect it. A blocker of ATP-dependent potassium channels (KATP channels), glibenclamide (200 µM), inhibited the ATP-induced relaxation and application of an opener of KATP channels, nicorandil (50 µM), produced relaxation. The findings suggest that ATP is involved in inhibitory regulation of the longitudinal smooth muscle in the muscularis mucosae of the rat esophagus via activation of P2Y receptors and then opening of KATP channels.


Asunto(s)
Adenosina Trifosfato , Esófago , Canales KATP , Músculo Liso , Receptores Purinérgicos P2Y , Animales , Ratas , Músculo Liso/efectos de los fármacos , Músculo Liso/fisiología , Músculo Liso/metabolismo , Masculino , Receptores Purinérgicos P2Y/metabolismo , Esófago/efectos de los fármacos , Esófago/fisiología , Adenosina Trifosfato/metabolismo , Adenosina Trifosfato/farmacología , Canales KATP/metabolismo , Relajación Muscular/efectos de los fármacos , Relajación Muscular/fisiología , Ratas Wistar , Contracción Muscular/efectos de los fármacos , Contracción Muscular/fisiología , Antagonistas del Receptor Purinérgico P2Y/farmacología , Motilidad Gastrointestinal/efectos de los fármacos , Motilidad Gastrointestinal/fisiología , Ratas Sprague-Dawley
7.
J Appl Physiol (1985) ; 136(6): 1418-1428, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38602001

RESUMEN

Breathing effort is important to quantify to understand mechanisms underlying central and obstructive sleep apnea, respiratory-related arousals, and the timing and effectiveness of invasive or noninvasive mechanically assisted ventilation. Current quantitative methods to evaluate breathing effort rely on inspiratory esophageal or epiglottic pressure swings or changes in diaphragm electromyographic (EMG) activity, where units are problematic to interpret and compare between individuals and to measured ventilation. This paper derives a novel method to quantify breathing effort in units directly comparable with measured ventilation by applying respiratory mechanics first principles to convert continuous transpulmonary pressure measurements into "attempted" airflow expected to have arisen without upper airway obstruction. The method was evaluated using data from 11 subjects undergoing overnight polysomnography, including six patients with obesity with severe obstructive sleep apnea (OSA), including one who also had frequent central events, and five healthy-weight controls. Classic respiratory mechanics showed excellent fits of airflow and volume to transpulmonary pressures during wake periods of stable unobstructed breathing (means ± SD, r2 = 0.94 ± 0.03), with significantly higher respiratory system resistance in patients compared with healthy controls (11.2 ± 3.3 vs. 7.1 ± 1.9 cmH2O·L-1·s, P = 0.032). Subsequent estimates of attempted airflow from transpulmonary pressure changes clearly highlighted periods of acute and prolonged upper airway obstruction, including within the first few breaths following sleep onset in patients with OSA. This novel technique provides unique quantitative insights into the complex and dynamically changing interrelationships between breathing effort and achieved airflow during periods of obstructed breathing in sleep.NEW & NOTEWORTHY Ineffective breathing efforts with snoring and obstructive sleep apnea (OSA) are challenging to quantify. Measurements of esophageal or epiglottic pressure swings and diaphragm electromyography are useful, but units are problematic to interpret and compare between individuals and to measured ventilation. This paper derives a novel method that uses esophageal pressure and respiratory mechanics first principles to quantify breathing effort as "attempted" flow and volume in units directly comparable with measured airflow, volume, and ventilation.


Asunto(s)
Esófago , Polisomnografía , Mecánica Respiratoria , Apnea Obstructiva del Sueño , Humanos , Mecánica Respiratoria/fisiología , Masculino , Femenino , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico , Persona de Mediana Edad , Adulto , Polisomnografía/métodos , Esófago/fisiopatología , Esófago/fisiología , Presión , Respiración , Trabajo Respiratorio/fisiología
8.
Am J Physiol Gastrointest Liver Physiol ; 326(6): G726-G735, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38626405

RESUMEN

During pharyngeal phase of swallowing, circumferential tension of the cervical esophagus (CTE) increases caused by a biomechanical process of laryngeal elevation pulling the cervical esophagus orad. The esophagus contracts longitudinally during esophageal peristalsis, therefore, we hypothesized that CTE increases during esophageal peristalsis by a biomechanical process. We investigated this hypothesis using 28 decerebrate cats instrumented with electromyographic (EMG) electrodes on the pharynx and esophagus, and esophageal manometry. We recorded CTE, distal esophageal longitudinal tension (DET), and orad laryngeal tension (OLT) using strain gauges. Peristalsis was stimulated by injecting saline into esophagus or nasopharynx. We investigated the effects of transecting the pharyngo-esophageal nerve (PEN), hypoglossal nerve (HG), or administering (10 mg/kg iv) hexamethonium (HEX). We found that the durations of CTE and DET increased and OLT decreased simultaneously during the total extent of esophageal peristalsis. CTE duration was highly correlated with DET but not esophageal EMG or manometry. The peak magnitudes of the DET and CTE were highly correlated. After HEX administration, peristalsis in the distal esophagus did not occur, and the duration of the CTE response decreased. PEN transection blocked the occurrence of cricopharyngeal or cervical esophageal response during peristalsis but had no significant effect on the CTE response. HG transection had no significant effect on CTE. We conclude that there is a significant CTE increase, independent of laryngeal elevation or esophageal muscle contraction, which occurs during esophageal peristalsis. This response is a biomechanical process caused by esophageal shortening that occurs during esophageal longitudinal contraction of esophageal peristalsis.NEW & NOTEWORTHY Circumferential tension of cervical esophagus (CTE) increases during esophageal peristalsis. CTE response is correlated with distal longitudinal tension on cervical esophagus during esophageal peristalsis but not laryngeal elevation or esophageal muscle contraction. CTE response is not blocked by transection of motor innervation of laryngeal elevating muscles or proximal esophagus but is temporally reduced after hexamethonium administration. We conclude that the CTE response is a biomechanical effect caused by longitudinal esophageal contraction during esophageal peristalsis.


Asunto(s)
Esófago , Peristaltismo , Peristaltismo/fisiología , Esófago/fisiología , Esófago/inervación , Animales , Fenómenos Biomecánicos , Gatos , Manometría , Masculino , Deglución/fisiología , Electromiografía , Contracción Muscular/fisiología , Faringe/fisiología , Femenino
9.
Neurogastroenterol Motil ; 36(6): e14787, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38523349

RESUMEN

BACKGROUND: Experimental research evaluating differences between the visceral and somatic stimulation is limited to pain and typically uses different induction methods for visceral and somatic stimulation (e.g., rectal balloon distention vs. tactile hand stimulation). Our study aimed to compare differences in response time, intensity, unpleasantness, and threat between identical electrical visceral and somatic stimulations at both painful and non-painful perceptual thresholds. METHODS: Electrical stimulation was applied to the wrist and distal esophagus in 20 healthy participants. A double pseudorandom staircase determined perceptual thresholds of Sensation, Discomfort, and Pain for the somatic and visceral stimulations, separately. Stimulus reaction time (ms, via button press), and intensity, unpleasantness, and threat ratings were recorded after each stimulus. General linear mixed models compared differences in the four outcomes by stimulation type, threshold, and the stimulation type-by-threshold interaction. Sigmoidal maximum effect models evaluated differences in outcomes across all delivered stimulation intensities. KEY RESULTS: Overall, visceral stimulations were perceived as more intense, threatening, and unpleasant compared to somatic stimulations, but participants responded faster to somatic stimulations. There was no significant interaction effect, but planned contrasts demonstrated differences at individual thresholds. Across all delivered intensities, higher intensity stimulations were needed to reach the half-maximum effect of self-reported intensity, unpleasantness, and threat ratings in the visceral domain. CONCLUSIONS AND INFERENCES: Differences exist between modalities for both non-painful and painful sensations. These findings may have implications for translating paradigms and behavioral treatments from the somatic domain to the visceral domain, though future research in larger clinical samples is needed.


Asunto(s)
Emociones , Humanos , Masculino , Femenino , Adulto , Emociones/fisiología , Adulto Joven , Estimulación Eléctrica/métodos , Umbral del Dolor/fisiología , Percepción del Dolor/fisiología , Sensación/fisiología , Dolor Visceral/fisiopatología , Dolor Visceral/psicología , Esófago/fisiología , Dolor/psicología , Dolor/fisiopatología , Tiempo de Reacción/fisiología
10.
J Clin Monit Comput ; 38(3): 701-714, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38310590

RESUMEN

Esophageal pressure (Peso) is one of the most common and minimally invasive methods used to assess the respiratory and lung mechanics in patients receiving mechanical ventilation. However, the Peso measurement is contaminated by cardiogenic oscillations (CGOs), which cannot be easily eliminated in real-time. The field of study dealing with the elimination of CGO from Peso signals is still in the early stages of its development. In this study, we present an adaptive filtering-based method by constructing a reference signal based on the heart rate and sine function to remove CGOs in real-time. The proposed technique is tested using clinical data acquired from 20 patients admitted to the intensive care unit. Lung compliance ( QUOTE ) and esophageal pressure swings (△Pes) are used to evaluate the performance and efficiency of the proposed technique. The CGO can be efficiently suppressed when the constructional reference signal contains the fundamental, and second and third harmonic frequencies of the heart rate signal. The analysis of the data of 8 patients with controlled mechanical ventilation reveals that the standard deviation/mean of the QUOTE is reduced by 28.4-79.2% without changing the QUOTE and the △Pes measurement is more accurate, with the use of our proposed technique. The proposed technique can effectively eliminate the CGOs from the measured Peso signals in real-time without requiring additional equipment to collect the reference signal.


Asunto(s)
Algoritmos , Esófago , Frecuencia Cardíaca , Respiración Artificial , Procesamiento de Señales Asistido por Computador , Humanos , Frecuencia Cardíaca/fisiología , Esófago/fisiología , Respiración Artificial/métodos , Masculino , Presión , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Femenino , Persona de Mediana Edad , Unidades de Cuidados Intensivos , Rendimiento Pulmonar , Anciano , Mecánica Respiratoria , Relación Señal-Ruido , Reproducibilidad de los Resultados
11.
Curr Opin Crit Care ; 30(1): 28-34, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38062927

RESUMEN

PURPOSE OF REVIEW: To summarize the key concepts, physiological rationale and clinical evidence for titrating positive end-expiratory pressure (PEEP) using transpulmonary pressure ( PL ) derived from esophageal manometry, and describe considerations to facilitate bedside implementation. RECENT FINDINGS: The goal of an esophageal pressure-based PEEP setting is to have sufficient PL at end-expiration to keep (part of) the lung open at the end of expiration. Although randomized studies (EPVent-1 and EPVent-2) have not yet proven a clinical benefit of this approach, a recent posthoc analysis of EPVent-2 revealed a potential benefit in patients with lower APACHE II score and when PEEP setting resulted in end-expiratory PL values close to 0 ±â€Š2 cmH 2 O instead of higher or more negative values. Technological advances have made esophageal pressure monitoring easier to implement at the bedside, but challenges regarding obtaining reliable measurements should be acknowledged. SUMMARY: Esophageal pressure monitoring has the potential to individualize the PEEP settings. Future studies are needed to evaluate the clinical benefit of such approach.


Asunto(s)
Pulmón , Respiración con Presión Positiva , Humanos , Manometría , Esófago/fisiología
13.
J Acoust Soc Am ; 153(6): 3428, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37350623

RESUMEN

Tracheoesophageal (TE) speech is an important method of speech rehabilitation for those who undergo a total laryngectomy. Despite the many advantages over other methods, there is still room for improvement in terms of the overall quality of the TE voice as well as its success rate. These points could be greatly assisted by an improved knowledge on the mechanics of TE speech. Here, an experimental model of the pharyngoesophageal segment (PES), based on the idea of a collapsible tube, is proposed. To implement the model, considerable simplifications had to be made, most notably in the use of a thin flexible tube to represent the PES. The model was used to assess the minimum amount of tonicity required for the onset of phonation in terms of the flow rate and longitudinal tension. Additionally, comparisons with a mathematical model [Tourinho, da Silva, dos Santos, Thomaz, and Vieira, J. Acoust. Soc. Am. 149, 1979-1988 (2021)] have been made, yielding similar trends for sufficiently large flow rates. The measurements also suggest that the phonation frequency is most affected by the tonicity of the PES, which highlights the question of which physiological mechanism is responsible for the control of the fundamental frequency of phonation.


Asunto(s)
Esófago , Laringe Artificial , Humanos , Esófago/fisiología , Calidad de la Voz/fisiología , Tráquea , Voz Esofágica/métodos , Fonación/fisiología , Laringectomía/rehabilitación , Modelos Teóricos
14.
Neuron ; 111(14): 2184-2200.e7, 2023 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-37192624

RESUMEN

Vagal sensory neurons monitor mechanical and chemical stimuli in the gastrointestinal tract. Major efforts are underway to assign physiological functions to the many distinct subtypes of vagal sensory neurons. Here, we use genetically guided anatomical tracing, optogenetics, and electrophysiology to identify and characterize vagal sensory neuron subtypes expressing Prox2 and Runx3 in mice. We show that three of these neuronal subtypes innervate the esophagus and stomach in regionalized patterns, where they form intraganglionic laminar endings. Electrophysiological analysis revealed that they are low-threshold mechanoreceptors but possess different adaptation properties. Lastly, genetic ablation of Prox2 and Runx3 neurons demonstrated their essential roles for esophageal peristalsis in freely behaving mice. Our work defines the identity and function of the vagal neurons that provide mechanosensory feedback from the esophagus to the brain and could lead to better understanding and treatment of esophageal motility disorders.


Asunto(s)
Subunidad alfa 3 del Factor de Unión al Sitio Principal , Esófago , Motilidad Gastrointestinal , Proteínas de Homeodominio , Células Receptoras Sensoriales , Nervio Vago , Animales , Ratones , Subunidad alfa 3 del Factor de Unión al Sitio Principal/genética , Subunidad alfa 3 del Factor de Unión al Sitio Principal/metabolismo , Esófago/inervación , Esófago/metabolismo , Esófago/fisiología , Motilidad Gastrointestinal/genética , Motilidad Gastrointestinal/fisiología , Proteínas de Homeodominio/genética , Proteínas de Homeodominio/metabolismo , Mecanorreceptores/fisiología , Neuronas Aferentes/fisiología , Células Receptoras Sensoriales/metabolismo , Células Receptoras Sensoriales/fisiología , Estómago/inervación , Estómago/metabolismo , Estómago/fisiología , Nervio Vago/fisiología
15.
Neurogastroenterol Motil ; 35(8): e14608, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37154414

RESUMEN

BACKGROUND: Effect of inter-swallow interval on the contractility of smooth muscle esophagus is well-documented. However, the effects on peristalsis of the striated esophagus have not been systematically studied. A better understanding of striated esophagus motor function in health and disease may enhance the interpretation of manometric studies and inform clinical care. The aim of this study was to assess the effect of inter-swallow interval on striated esophagus compared to findings with that of the smooth muscle esophagus. METHODS: We performed two sets of studies to (1) determine the effect of various inter-swallow interval in 20 healthy volunteers and (2) assess the effect of ultra-short swallow intervals facilitated by straw drinking in 28 volunteers. We analyzed variables using ANOVA with Tukey's pairwise comparison and paired t-test. KEY RESULTS: Unlike smooth muscle esophagus, the striated esophagus contractile integral did not change significantly for swallow intervals ranging from 30 to 5 s. On the contrary, striated esophagus demonstrated absent or reduced peristalsis in response to ultra-short (<2 s) intervals during straw-facilitated multiple rapid swallows. CONCLUSIONS AND INFERENCES: Striated esophagus peristalsis is subject to manometrically observed inhibition during swallows with ultra-short intervals. Inter-swallow intervals as short as 5 s that inhibit smooth muscle esophagus peristalsis do not inhibit striated muscle peristalsis. The mechanisms of these observations are unknown but may relate to central or myenteric nervous system influences or the effects of pharyngeal biomechanics.


Asunto(s)
Deglución , Peristaltismo , Humanos , Peristaltismo/fisiología , Deglución/fisiología , Esófago/fisiología , Músculo Liso/fisiología , Contracción Muscular/fisiología , Manometría
16.
J Appl Physiol (1985) ; 134(3): 549-557, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36656979

RESUMEN

Evidence obtained ex vivo suggests that physical elongation of the esophagus increases esophageal circumferential stress-strain ratio, but it is unknown whether this biomechanical effect alters esophageal function in vivo. We investigated the effects of physical or physiological elongation of the cervical esophagus on basal and active circumferential tension in vivo. The esophagus was elongated, using 29 decerebrate cats, either physically by distal physical extension of the esophagus or physiologically by stimulating the hypoglossal nerve, which activates laryngeal elevating muscles that elongate the esophagus. Hyoid, pharyngeal, and esophageal muscles were instrumented with electromyogram (EMG) electrodes and/or strain gauge force transducers. Esophageal intraluminal manometry was also recorded. We found that physical or physiological elongation of the cervical esophagus increased esophageal circumferential basal as well as active tension initiated by electrical stimulation of the pharyngo-esophageal nerve or the esophageal muscle directly, but did not increase esophageal intraluminal pressure or EMG activity. The esophageal circumferential response to the esophago-esophageal contractile reflex was increased by distal physical elongation, but not orad physiological elongation. We conclude that physical or physiological elongation of the esophagus significantly increases esophageal circumferential basal and active tension without muscle activation. We hypothesize that this effect is caused by an increase in esophageal stress-strain ratio by a biomechanical process, which increases circumferential wall stiffness. The increase in esophageal circumferential stiffness increases passive tension and the effectiveness of active tension. This increase in cervical esophageal circumferential stiffness may alter esophageal function.NEW & NOTEWORTHY Physical or physiological esophageal elongation increases esophageal circumferential active or passive tension by a biomechanical process, which causes a decrease in esophageal circumferential elasticity. This increased stiffness of the esophageal wall likely promotes esophageal bolus flow during various esophageal functions.


Asunto(s)
Deglución , Esófago , Deglución/fisiología , Esófago/fisiología , Faringe/fisiología , Reflejo/fisiología , Músculo Liso
17.
Respir Physiol Neurobiol ; 309: 104012, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36592844

RESUMEN

Quantifying diaphragm neuromuscular function using cervical magnetic stimulation (CMS) typically uses only a single stimulator (1-Stim) which may be inadequate to maximally stimulate the phrenic nerves. We questioned if using two stimulators (2-Stim) together alters diaphragm neuromuscular function at baseline and following inspiratory pressure threshold loading. Six (n = 3 female) healthy young participants were instrumented with esophageal and gastric balloon tipped catheters and electrodes over the 7-8th intercostal space. With either 1-Stim or 2-Stim an incremental protocol, where the stimulator intensity was progressively increased was completed prior to a series of potentiated twitches. The inspiratory threshold loading test consisted of loaded breathing to failure. Compared to 1-Stim, 2-Stim resulted in significantly greater unpotentiated Pditw and M-waves during the incremental protocol (both p < 0.01). Similarly, 2-Stim resulted in greater potentiated Pditw (31 ± 8 vs. 41 ± 9 cmH2O; p = 0.02) and M-waves (6.4 ± 2.9 vs. 8.6 ± 2.4 V; p = 0.02). Our findings suggest that CMS using 1-Stim is unlikely to generate a sufficient magnetic field to maximally stimulate the phrenic nerves and may underestimate diaphragm function.


Asunto(s)
Diafragma , Respiración , Humanos , Femenino , Esófago/fisiología , Nervio Frénico/fisiología , Campos Magnéticos , Fenómenos Magnéticos
18.
Dis Esophagus ; 36(8)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-36572397

RESUMEN

Gastroesophageal reflux disease (GERD) is common in patients who have undergone lung transplantation and is associated with poorer outcomes, but guidelines are lacking to direct management strategies in this population. We assessed the diagnostic yield of impedance metrics compared to pH-metry alone for detecting GERD among lung transplant recipients and evaluated their association with clinical outcomes. We performed a retrospective cohort study of consecutive patients who underwent lung transplantation. Demographic data, acid exposure time (AET), number of reflux episodes, mean nocturnal baseline impedance (MNBI), post-reflux swallowing-induced peristaltic wave index (PSPWI), and clinical outcomes including mortality were collected. The relationship between GERD metrics and clinical outcomes was assessed using Wilcoxon signed-rank test and Fisher's exact test as appropriate. Of the 76 patients studied, 29 (38%) had GERD based on abnormal AET after lung transplantation. One (1.3%) patient had GERD based on elevated number of reflux episodes and abnormal distal MNBI detected GERD in 19 (26%) patients, resulting in 62% sensitivity and 94% specificity. Two (2.6%) patients had normal PSPWI. Patients with low distal MNBI had significantly decreased forced expiratory volume in 1 second (FEV1) at 3-year posttransplant compared to those without low distal MNBI (P = 0.03). Three-year survival was significantly worse among patients with elevated AET (66.7% vs. 89.1%, P = 0.03) but not with low distal MNBI (68.4% vs. 84.3%, P = 0.18). Abnormal AET is more sensitive for detecting GERD than other reflux metrics studied and is associated with survival, suggesting pH-metry alone may be sufficient to guide GERD management after lung transplant.


Asunto(s)
Impedancia Eléctrica , Monitorización del pH Esofágico , Reflujo Gastroesofágico , Trasplante de Pulmón , Reflujo Gastroesofágico/diagnóstico , Sobrevivientes , Estudios Retrospectivos , Esófago/fisiología
19.
Anat Rec (Hoboken) ; 306(5): 960-971, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35838072

RESUMEN

Serotonin immunoreactivity was previously found in myenteric neurons co-innervating motor endplates in the mouse esophagus striated muscle and an involvement in motility control was suggested. However, it is not known if other neuroactive substances are present in these neurons and to what extent they co-localize. First, vasoactive intestinal peptide (VIP) was established as a bona fide marker for putative inhibitory myenteric neurons by evaluating co-localization with neuronal nitric oxide synthase (nNOS) and neuropeptide Y (NPY). Then, co-localization of serotonin and VIP was tested in co-innervating axons on motor endplates, which were visualized with α-bungarotoxin (α-BT) by multilabel immunofluorescence. Myenteric ganglia were also surveyed for co-localization in neuronal perikarya and varicosities. nNOS, NPY, and VIP were completely co-localized in enteric co-innervating nerve terminals on motor endplates. After co-staining with VIP, we found (a) serotonin (5-HT)-positive nerve endings without VIP (44% of 5-HT-positively innervated endplates), (b) 5-HT- and VIP-positive endings without co-localization (35%), and (c) 5-HT- and VIP-positive endings with co-localization (21%). About one-fifth of nerve terminals on motor endplates containing 5-HT originate from putative inhibitory peptidegic nitrergic neurons. However, the majority represents a different population presumably subserving different functions.


Asunto(s)
Placa Motora , Serotonina , Animales , Ratones , Neuronas , Péptido Intestinal Vasoactivo , Esófago/inervación , Esófago/fisiología , Plexo Mientérico
20.
J Clin Monit Comput ; 37(1): 221-226, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35674857

RESUMEN

To validate the pressure-time index of the inspiratory muscles as a non-invasive index of inspiratory muscle function in spontaneously breathing infants by comparing it against the gold-standard pressure-time index of the diaphragm. Prospective observational cohort study of consecutive infants breathing unsupported in room air in a tertiary neonatal intensive care unit, studied prior to discharge from neonatal care. The invasive pressure-time index of the diaphragm was calculated using a transdiaphragmatic dual-pressure catheter that measured transdiaphragmatic pressure by subtraction of the oesophageal from the gastric pressure. The non-invasive pressure-time index of the inspiratory muscles was calculated using pressure measurements at the level of the mouth via a differential pressure transducer connected to a face mask. Both indices were calculated as the product of the ratio of the mean inspiratory pressure divided by the maximum inspiratory pressure and the ratio of the inspiratory time divided by the total time of a respiratory cycle. One hundred and thirty infants (79 male) were included with a mean (SD) gestational age of 35.2 (3.2) weeks, studied at a median (IQR) postnatal age of 9 (6-20) days. The mean (SD) pressure-time index of the diaphragm was 0.063 (0.019) and the mean (SD) pressure-time index of the inspiratory muscles was 0.065 (0.023). The correlation coefficient for the two indices was 0.509 (p < 0.001). The mean (SD) absolute difference between the pressure-time index of the inspiratory muscles and pressure-time index of the diaphragm was 0.002 (0.021). In convalescent infants, the non-invasive pressure-time index of the inspiratory muscles had a moderate degree of correlation with the invasively derived pressure time index of the diaphragm measured with a transdiaphragmatic catheter.


Asunto(s)
Diafragma , Músculos Respiratorios , Recién Nacido , Humanos , Masculino , Lactante , Músculos Respiratorios/fisiología , Estudios Prospectivos , Diafragma/fisiología , Respiración , Esófago/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA