Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Anal Chem ; 92(23): 15454-15462, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33170641

RESUMEN

The superior mass sensitivity of microcoil technology in nuclear magnetic resonance (NMR) spectroscopy provides potential for the analysis of extremely small-mass-limited samples such as eggs, cells, and tiny organisms. For optimal performance and efficiency, the size of the microcoil should be tailored to the size of the mass-limited sample of interest, which can be costly as mass-limited samples come in many shapes and sizes. Therefore, rapid and economic microcoil production methods are needed. One method with great potential is 5-axis computer numerical control (CNC) micromilling, commonly used in the jewelry industry. Most CNC milling machines are designed to process larger objects and commonly have a precision of >25 µm (making the machining of common spiral microcoils, for example, impossible). Here, a 5-axis MiRA6 CNC milling machine, specifically designed for the jewelry industry, with a 0.3 µm precision was used to produce working planar microcoils, microstrips, and novel microsensor designs, with some tested on the NMR in less than 24 h after the start of the design process. Sample wells could be built into the microsensor and could be machined at the same time as the sensors themselves, in some cases leaving a sheet of Teflon as thin as 10 µm between the sample and the sensor. This provides the freedom to produce a wide array of designs and demonstrates 5-axis CNC micromilling as a versatile tool for the rapid prototyping of NMR microsensors. This approach allowed the experimental optimization of a prototype microstrip for the analysis of two intact adult Daphnia magna organisms. In addition, a 3D volume slotted-tube resonator was produced that allowed for 2D 1H-13C NMR of D. magna neonates and exhibited 1H sensitivity (nLODω600 = 1.49 nmol s1/2) close to that of double strip lines, which themselves offer the best compromise between concentration and mass sensitivity published to date.


Asunto(s)
Costos y Análisis de Costo , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Microtecnología/instrumentación , Animales , Daphnia/química , Diseño de Equipo , Fenómenos Mecánicos , Factores de Tiempo
2.
J Magn Reson ; 319: 106800, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33036708

RESUMEN

While NMR and MRI are often thought of as expensive techniques requiring large institutional investment, opportunities for low-cost, low-field NMR and MRI abound. We discuss a number of approaches to performing magnetic resonance experiments with inexpensive, easy to find or build components, aimed at applications in industry, education, and research. Opportunities that aim to make NMR accessible to a broad community are highlighted. We describe and demonstrate some projects from our laboratory, including a new prototype instrument for measurements at frequencies up to ∼200 kHz and demonstrate its application to the study of the rapidly advancing technique known as inhomogeneous magnetization transfer imaging, a promising method for characterizing myelin in vivo.


Asunto(s)
Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Neuroimagen/instrumentación , Diseño de Equipo , Humanos , Programas Informáticos
3.
Future Microbiol ; 13: 1165-1173, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29792512

RESUMEN

The mortality associated with invasive candidiasis remains unacceptably high. The T2 magnetic resonance (T2MR) assay is a novel US FDA-approved molecular diagnostic assay for the diagnosis of candidemia that can rapidly detect the five most commonly isolated Candida spp. In clinical trials, T2MR has exhibited good clinical sensitivity and specificity. Potential benefits from the adoption of T2MR technology in the diagnostic and therapeutic algorithms for invasive candidiasis can arise from timely diagnosis of disease, increased case detection, tailored therapy and decrease in empiric antifungal treatment. As everyday clinical experience with the assay is evolving, we discuss the utility of T2MR in invasive candidiasis with and without candidemia based on the currently available evidence regarding its performance.


Asunto(s)
Candidiasis Invasiva/diagnóstico por imagen , Antifúngicos/uso terapéutico , Candida/clasificación , Candida/fisiología , Candidemia/diagnóstico por imagen , Candidemia/tratamiento farmacológico , Candidiasis Invasiva/tratamiento farmacológico , Diagnóstico Precoz , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Espectroscopía de Resonancia Magnética/economía , Sensibilidad y Especificidad
4.
Anal Bioanal Chem ; 410(11): 2793-2804, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29480388

RESUMEN

Isotope labeling enables the use of 13C-based metabolomics techniques with strongly improved resolution for a better identification of relevant metabolites and tracing of metabolic fluxes in cell and animal models, as required in fluxomics studies. However, even at high NMR-active isotope abundance, the acquisition of one-dimensional 13C and classical two-dimensional 1H,13C-HSQC experiments remains time consuming. With the aim to provide a shorter, more efficient alternative, herein we explored the ALSOFAST-HSQC experiment with its rapid acquisition scheme for the analysis of 13C-labeled metabolites in complex biological mixtures. As an initial step, the parameters of the pulse sequence were optimized to take into account the specific characteristics of the complex samples. We then applied the fast two-dimensional experiment to study the effect of different kinds of antioxidant gold nanoparticles on a HeLa cancer cell model grown on 13C glucose-enriched medium. As a result, 1H,13C-2D correlations could be obtained in a couple of seconds to few minutes, allowing a simple and reliable identification of various 13C-enriched metabolites and the determination of specific variations between the different sample groups. Thus, it was possible to monitor glucose metabolism in the cell model and study the antioxidant effect of the coated gold nanoparticles in detail. Finally, with an experiment time of only half an hour, highly resolved 1H,13C-HSQC spectra using the ALSOFAST-HSQC pulse sequence were acquired, revealing the isotope-position-patterns of the corresponding 13C-nuclei from carbon multiplets. Graphical abstract Fast NMR applied to metabolomics and fluxomics studies with gold nanoparticles.


Asunto(s)
Antioxidantes/farmacología , Glucosa/metabolismo , Oro/farmacología , Espectroscopía de Resonancia Magnética/métodos , Metabolómica/métodos , Neoplasias/metabolismo , Antioxidantes/química , Isótopos de Carbono/análisis , Isótopos de Carbono/metabolismo , Quitosano/química , Quitosano/farmacología , Glucosa/análisis , Oro/química , Células HeLa , Humanos , Espectroscopía de Resonancia Magnética/economía , Metaboloma/efectos de los fármacos , Metabolómica/economía , Nanopartículas del Metal/química , Neoplasias/tratamiento farmacológico , Factores de Tiempo
5.
Anal Chem ; 90(3): 1845-1851, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29303255

RESUMEN

The targeted analysis of metabolites in complex mixtures is a challenging issue. NMR is one of the major tools in this field, but there is a strong need for more sensitive, better-resolved, and faster quantitative methods. In this framework, we introduce the concept of FAst, QUantitative, hIghly Resolved and sEnsitivity enhanced (FAQUIRE) NMR to push forward the limits of metabolite NMR analysis. 2D 1H, 13C 2D quantitative maps are promising alternatives for enhancing the spectral resolution but are highly time-consuming because of (i) the intrinsic nature of 2D, (ii) the longer recycling times required for quantitative conditions, and (iii) the higher number of scans needed to reduce the level of detection/quantification to access low concentrated metabolites. To reach this aim, speeding up the recently developed QUantItative Perfected and pUre shifted HSQC (QUIPU HSQC) is an interesting attempt to develop the FAQUIRE concept. Thanks to the combination of spectral aliasing, nonuniform sampling, and variable repetition time, the acquisition time of 2D quantitative maps is reduced by a factor 6 to 9, while conserving a high spectral resolution thanks to a pure shift approach. The analytical potential of the new Quick QUIPU HSQC (Q QUIPU HSQC) is evaluated on a model metabolite sample, and its potential is shown on breast-cell extracts embedding metabolites at millimolar to submillimolar concentrations.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Aminoácidos/análisis , Neoplasias de la Mama/química , Isótopos de Carbono/análisis , Línea Celular Tumoral , Colina/análisis , Femenino , Humanos , Hidrógeno/análisis , Inositol/análisis , Ácido Láctico/análisis , Espectroscopía de Resonancia Magnética/economía , Factores de Tiempo
6.
MAGMA ; 30(3): 281-289, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28054143

RESUMEN

OBJECTIVE: To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy. MATERIALS AND METHODS: We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age ± standard deviation: 32.8 ± 6.0 years, BMI: 24.1 ± 3.9 kg/m2). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV). RESULTS: We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively. CONCLUSION: We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31P-MRS.


Asunto(s)
Prueba de Esfuerzo/instrumentación , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Músculo Esquelético/fisiología , Fosfocreatina/metabolismo , Recuperación de la Función/fisiología , Adulto , Análisis Costo-Beneficio , Diseño de Equipo , Análisis de Falla de Equipo , Prueba de Esfuerzo/economía , Prueba de Esfuerzo/métodos , Femenino , Humanos , Cinética , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/métodos , Masculino , Tasa de Depuración Metabólica , Contracción Muscular/fisiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
J Magn Reson ; 260: 20-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26397217

RESUMEN

Magnetic resonance imaging and spectroscopy of hyperpolarized (HP) compounds such as [1-(13)C]-pyruvate have shown tremendous potential for offering new insight into disease and response to therapy. New applications of this technology in clinical research and care will require extensive validation in cells and animal models, a process that may be limited by the high cost and modest throughput associated with dynamic nuclear polarization. Relatively wide spectral separation between [1-(13)C]-pyruvate and its chemical endpoints in vivo are conducive to simultaneous multi-sample measurements, even in the presence of a suboptimal global shim. Multi-channel acquisitions could conserve costs and accelerate experiments by allowing acquisition from multiple independent samples following a single dissolution. Unfortunately, many existing preclinical MRI systems are equipped with only a single channel for broadband acquisitions. In this work, we examine the feasibility of this concept using a broadband multi-channel digital receiver extension and detector arrays that allow concurrent measurement of dynamic spectroscopic data from ex vivo enzyme phantoms, in vitro anaplastic thyroid carcinoma cells, and in vivo in tumor-bearing mice. Throughput and the cost of consumables were improved by up to a factor of four. These preliminary results demonstrate the potential for efficient multi-sample studies employing hyperpolarized agents.


Asunto(s)
Isótopos de Carbono , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Metabolismo , Conversión Analogo-Digital , Animales , Carcinoma/enzimología , Carcinoma/metabolismo , Carcinoma/patología , Línea Celular Tumoral , Costos y Análisis de Costo , Enzimas/química , Diseño de Equipo , Estudios de Factibilidad , Humanos , L-Lactato Deshidrogenasa/química , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Ratones , Fantasmas de Imagen , Ácido Pirúvico/química , Relación Señal-Ruido , Neoplasias de la Tiroides/enzimología , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/patología
8.
J Magn Reson ; 259: 76-81, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26302269

RESUMEN

Magic-angle spinning (MAS) NMR is a powerful tool for studying molecular structure and dynamics, but suffers from its low sensitivity. Here, we developed a novel helium-cooling MAS NMR probe system adopting a closed-loop gas recirculation mechanism. In addition to the sensitivity gain due to low temperature, the present system has enabled highly stable MAS (vR=4-12 kHz) at cryogenic temperatures (T=35-120 K) for over a week without consuming helium at a cost for electricity of 16 kW/h. High-resolution 1D and 2D data were recorded for a crystalline tri-peptide sample at T=40 K and B0=16.4 T, where an order of magnitude of sensitivity gain was demonstrated versus room temperature measurement. The low-cost and long-term stable MAS strongly promotes broader application of the brute-force sensitivity-enhanced multi-dimensional MAS NMR, as well as dynamic nuclear polarization (DNP)-enhanced NMR in a temperature range lower than 100 K.


Asunto(s)
Helio/química , Espectroscopía de Resonancia Magnética/métodos , Frío , Electricidad , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Temperatura
10.
Expert Opin Drug Discov ; 8(7): 849-63, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23662912

RESUMEN

INTRODUCTION: Magnetic resonance spectroscopy (MRS) will continue to play an ever increasing role in drug discovery because MRS does readily define biomarkers for several hundreds of clinically distinct diseases. Published evidence based medicine (EBM) surveys, which generally conclude the opposite, are seriously flawed and do a disservice to the field of drug discovery. AREAS COVERED: This article presents MRS and how it has guided several hundreds of practical human 'drug discovery' endeavors since its development. Specifically, the author looks at the process of 'reverse-translation' and its influence in the expansion of the number of preclinical drug discoveries from in vivo MRS. The author also provides a structured approach of eight criteria, including EBM acceptance, which could potentially re-open the field of MRS for productive exploration of existing and repurposed drugs and cost-effective drug-discovery. EXPERT OPINION: MRS-guided drug discovery is poised for future expansion. The cost of clinical trials has escalated and the use of biomarkers has become increasingly useful in improving patient selection for drug trials. Clinical MRS has uncovered a treasure-trove of novel biomarkers and clinical MRS itself has become better standardized and more widely available on 'routine' clinical MRI scanners. When combined with available new MRI sequences, MRS can provide a 'one stop shop' with multiple potential outcome measures for the disease and the drug in question.


Asunto(s)
Descubrimiento de Drogas , Evaluación Preclínica de Medicamentos/métodos , Espectroscopía de Resonancia Magnética/métodos , Biomarcadores/metabolismo , Ensayos Clínicos como Asunto/economía , Ensayos Clínicos como Asunto/métodos , Ensayos Clínicos como Asunto/normas , Diseño de Fármacos , Evaluación Preclínica de Medicamentos/economía , Humanos , Espectroscopía de Resonancia Magnética/economía
11.
Health Technol Assess ; 17(20): vii-xix, 1-281, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23697373

RESUMEN

BACKGROUND: In the UK, prostate cancer (PC) is the most common cancer in men. A diagnosis can be confirmed only following a prostate biopsy. Many men find themselves with an elevated prostate-specific antigen (PSA) level and a negative biopsy. The best way to manage these men remains uncertain. OBJECTIVES: To assess the diagnostic accuracy of magnetic resonance spectroscopy (MRS) and enhanced magnetic resonance imaging (MRI) techniques [dynamic contrast-enhanced MRI (DCE-MRI), diffusion-weighted MRI (DW-MRI)] and the clinical effectiveness and cost-effectiveness of strategies involving their use in aiding the localisation of prostate abnormalities for biopsy in patients with prior negative biopsy who remain clinically suspicious for harbouring malignancy. DATA SOURCES: Databases searched--MEDLINE (1946 to March 2012), MEDLINE In-Process & Other Non-Indexed Citations (March 2012), EMBASE (1980 to March 2012), Bioscience Information Service (BIOSIS; 1995 to March 2012), Science Citation Index (SCI; 1995 to March 2012), The Cochrane Library (Issue 3 2012), Database of Abstracts of Reviews of Effects (DARE; March 2012), Medion (March 2012) and Health Technology Assessment database (March 2012). REVIEW METHODS: Types of studies: direct studies/randomised controlled trials reporting diagnostic outcomes. INDEX TESTS: MRS, DCE-MRI and DW-MRI. Comparators: T2-weighted magnetic resonance imaging (T2-MRI), transrectal ultrasound-guided biopsy (TRUS/Bx). Reference standard: histopathological assessment of biopsied tissue. A Markov model was developed to assess the cost-effectiveness of alternative MRS/MRI sequences to direct TRUS-guided biopsies compared with systematic extended-cores TRUS-guided biopsies. A health service provider perspective was adopted and the recommended 3.5% discount rate was applied to costs and outcomes. RESULTS: A total of 51 studies were included. In pooled estimates, sensitivity [95% confidence interval (CI)] was highest for MRS (92%; 95% CI 86% to 95%). Specificity was highest for TRUS (imaging test) (81%; 95% CI 77% to 85%). Lifetime costs ranged from £3895 using systematic TRUS-guided biopsies to £4056 using findings on T2-MRI or DCE-MRI to direct biopsies (60-year-old cohort, cancer prevalence 24%). The base-case incremental cost-effectiveness ratio for T2-MRI was <£30,000 per QALY (all cohorts). Probabilistic sensitivity analysis showed high uncertainty surrounding the incremental cost-effectiveness of T2-MRI in moderate prevalence cohorts. The cost-effectiveness of MRS compared with T2-MRI and TRUS was sensitive to several key parameters. LIMITATIONS: Non-English-language studies were excluded. Few studies reported DCE-MRI/DW-MRI. The modelling was hampered by limited data on the relative diagnostic accuracy of alternative strategies, the natural history of cancer detected at repeat biopsy, and the impact of diagnosis and treatment on disease progression and health-related quality of life. CONCLUSIONS: MRS had higher sensitivity and specificity than T2-MRI. Relative cost-effectiveness of alternative strategies was sensitive to key parameters/assumptions. Under certain circumstances T2-MRI may be cost-effective compared with systematic TRUS. If MRS and DW-MRI can be shown to have high sensitivity for detecting moderate/high-risk cancer, while negating patients with no cancer/low-risk disease to undergo biopsy, their use could represent a cost-effective approach to diagnosis. However, owing to the relative paucity of reliable data, further studies are required. In particular, prospective studies are required in men with suspected PC and elevated PSA levels but previously negative biopsy comparing the utility of the individual and combined components of a multiparametric magnetic resonance (MR) approach (MRS, DCE-MRI and DW-MRI) with both a MR-guided/-directed biopsy session and an extended 14-core TRUS-guided biopsy scheme against a reference standard of histopathological assessment of biopsied tissue obtained via saturation biopsy, template biopsy or prostatectomy specimens. STUDY REGISTRATION: PROSPERO number CRD42011001376. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Asunto(s)
Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Próstata/patología , Neoplasias de la Próstata/diagnóstico , Biopsia/métodos , Análisis Costo-Beneficio , Imagen de Difusión por Resonancia Magnética/economía , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/métodos , Masculino , Neoplasias de la Próstata/economía , Neoplasias de la Próstata/patología
12.
J Magn Reson ; 232: 31-8, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23685716

RESUMEN

The nuclear-spin optical rotation (NSOR) effect recently attracted much attention due to potential applications in combined optical-NMR spectroscopy and imaging. Currently, the main problem with applications of NSOR is low SNR and accuracy of measurements. In this work we demonstrate a new method for data acquisition and analysis based on a low-power laser and an emphasis on software based processing. This method significantly reduces cost and is suitable for application in most NMR spectroscopy laboratories for exploration of the NSOR effect. Despite the use of low laser power, SNR can be substantially improved with fairly simple strategies including the use of short wavelength and a multi-pass optical cell with in-flow pre-polarization in a 7 T magnet. Under these conditions, we observed that NSOR signal can be detected in less than 1 min and discuss strategies for further improvement of signal. With higher SNR than previously reported, NSOR constants can be extracted with improved accuracy. On the example of water, we obtained measurements at a level of accuracy of 5%. We include a detailed theoretical analysis of the geometrical factors of the experiment, which is required for accurate quantification of NSOR. This discussion is particularly important for relatively short detection cells, which will be necessary to use in spectroscopy or imaging applications that impose geometrical constraints.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Rotación Óptica , Algoritmos , Rayos Láser , Imagen por Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/economía , Agua
13.
Chem Pharm Bull (Tokyo) ; 61(12): 1264-8, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24436958

RESUMEN

Carthamus Red is a food colorant prepared from the petals of Carthamus tinctorius (Asteraceae) whose major pigment is carthamin. Since an authentic carthamin standard is difficult to obtain commercially for the preparation of calibration curves in HPLC assays, we applied (1)H-NMR spectroscopy to the quantitative determination of carthamin in commercial preparations of Carthamus Red. Carthamus Red was repeatedly extracted in methanol and the extract was dissolved in pyridine-d(5) containing hexamethyldisilane (HMD) prior to (1)H-NMR spectroscopic analysis. The carthamin contents were calculated from the ratios of singlet signal intensities at approximately σ: 9.3 derived from H-16 of carthamin to those of the HMD signal at σ: 0. The integral ratios exhibited good repeatability among NMR spectroscopic analyses. Both the intra-day and inter-day assay variations had coefficients of variation of <5%. Based on the coefficient of absorption, the carthamin contents of commercial preparations determined by (1)H-NMR spectroscopy correlated well with those determined by colorimetry, although the latter were always approximately 1.3-fold higher than the former, irrespective of the Carthamus Red preparations. In conclusion, the quantitative (1)H-NMR spectroscopy used in the present study is simple and rapid, requiring no carthamin standard for calibration. After HMD concentration has been corrected using certified reference materials, the carthamin contents determined by (1)H-NMR spectroscopy are System of Units (SI)-traceable.


Asunto(s)
Carthamus tinctorius/química , Chalcona/análogos & derivados , Glucósidos/análisis , Espectroscopía de Resonancia Magnética/métodos , Pigmentos Biológicos/análisis , Chalcona/análisis , Chalcona/aislamiento & purificación , Cromatografía Líquida de Alta Presión/economía , Cromatografía Líquida de Alta Presión/métodos , Glucósidos/aislamiento & purificación , Límite de Detección , Espectroscopía de Resonancia Magnética/economía , Pigmentos Biológicos/aislamiento & purificación , Reproducibilidad de los Resultados
14.
Anal Chem ; 84(20): 8777-82, 2012 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-22971210

RESUMEN

During the development of new materials demonstrating biological activity, prediction and identification of reactive intermediates generated in the course of drug metabolism in the human liver is of great importance. We present a rapid and purely instrumental method for the structure elucidation of possible phase I metabolites. With electrochemical (EC) conversion adopting the oxidative function of liver-inherent enzymes and nuclear magnetic resonance (NMR) spectroscopy enabling structure elucidation, comprehensive knowledge on potential metabolites can be gained. Paracetamol (APAP) has been known to induce hepatotoxicity when exceeding therapeutic doses and was therefore selected as the test compound. The reactive metabolite N-acetyl-p-benzoquinone imine has long been proven to be responsible for the toxic side effects of APAP and can easily be generated by EC. EC coupled online to NMR is a straightforward technique for structure elucidation of reactive drug intermediates at an early stage in drug discovery.


Asunto(s)
Acetaminofén/metabolismo , Analgésicos no Narcóticos/metabolismo , Benzoquinonas/metabolismo , Técnicas Electroquímicas/instrumentación , Iminas/metabolismo , Hígado/enzimología , Espectroscopía de Resonancia Magnética/instrumentación , Acetaminofén/química , Acetaminofén/toxicidad , Analgésicos no Narcóticos/química , Analgésicos no Narcóticos/toxicidad , Benzoquinonas/química , Benzoquinonas/toxicidad , Evaluación Preclínica de Medicamentos/economía , Evaluación Preclínica de Medicamentos/instrumentación , Técnicas Electroquímicas/economía , Diseño de Equipo , Humanos , Iminas/química , Iminas/toxicidad , Hígado/efectos de los fármacos , Espectroscopía de Resonancia Magnética/economía , Oxidación-Reducción
15.
Org Biomol Chem ; 10(31): 6410-9, 2012 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-22735343

RESUMEN

The three-component chiral derivatization protocols have been developed for (1)H, (13)C and (19)F NMR spectroscopic discrimination of chiral diacids by their coordination and self-assembly with optically active (R)-α-methylbenzylamine and 2-formylphenylboronic acid or 3-fluoro-2-formylmethylboronic acid. These protocols yield a mixture of diastereomeric imino-boronate esters which are identified by the well-resolved diastereotopic peaks with significant chemical shift differences ranging up to 0.6 and 2.1 ppm in their corresponding (1)H and (19)F NMR spectra, without any racemization or kinetic resolution, thereby enabling the determination of enantiopurity. A protocol has also been developed for discrimination of chiral alpha-methyl amines, using optically pure trans-1,2-cyclohexanedicarboxylic acid in combination with 2-formylphenylboronic acid or 3-fluoro-2-fluoromethylboronic acid. The proposed strategies have been demonstrated on large number of chiral diacids and chiral alpha-methyl amines.


Asunto(s)
Ácidos Carboxílicos/química , Espectroscopía de Resonancia Magnética/métodos , Metilaminas/química , Benzaldehídos/química , Ácidos Borónicos/química , Ácidos Ciclohexanocarboxílicos/química , Ácidos Dicarboxílicos/química , Ésteres/química , Halogenación , Espectroscopía de Resonancia Magnética/economía , Fenetilaminas/química , Estereoisomerismo
16.
Solid State Nucl Magn Reson ; 43-44: 14-21, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22365288

RESUMEN

Para hydrogen induced polarization (PHIP) is a powerful hyperpolarization technique, which increases the NMR sensitivity by several orders of magnitude. However the hyperpolarized signal is created as an anti-phase signal, which necessitates high magnetic field homogeneity and spectral resolution in the conventional PHIP schemes. This hampers the application of PHIP enhancement in many fields, as for example in food science, materials science or MRI, where low B(0)-fields or low B(0)-homogeneity do decrease spectral resolution, leading to potential extinction if in-phase and anti-phase hyperpolarization signals cannot be resolved. Herein, we demonstrate that the echo sequence (45°-τ-180°-τ) enables the acquisition of low resolution PHIP enhanced liquid state NMR signals of phenylpropiolic acid derivatives and phenylacetylene at a low cost low-resolution 0.54 T spectrometer. As low field TD-spectrometers are commonly used in industry or biomedicine for the relaxometry of oil-water mixtures, food, nano-particles, or other systems, we compare two variants of para-hydrogen induced polarization with data-evaluation in the time domain (TD-PHIP). In both TD-ALTADENA and the TD-PASADENA strong spin echoes could be detected under conditions when usually no anti-phase signals can be measured due to the lack of resolution. The results suggest that the time-domain detection of PHIP-enhanced signals opens up new application areas for low-field PHIP-hyperpolarization, such as non-invasive compound detection or new contrast agents and biomarkers in low-field Magnetic Resonance Imaging (MRI). Finally, solid-state NMR calculations are presented, which show that the solid echo (90y-τ-90x-τ) version of the TD-ALTADENA experiment is able to convert up to 10% of the PHIP signal into visible magnetization.


Asunto(s)
Hidrógeno/química , Espectroscopía de Resonancia Magnética/métodos , Acetileno/análogos & derivados , Acetileno/química , Espectroscopía de Resonancia Magnética/economía , Fenilpropionatos/química , Factores de Tiempo
17.
Anal Chem ; 84(6): 2868-74, 2012 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-22320312

RESUMEN

Differences in molecular chirality remain an important issue in drug metabolism and pharmacokinetics for the pharmaceutical industry and regulatory authorities, and chirality is an important feature of many endogenous metabolites. We present a method for the rapid, direct differentiation and identification of chiral drug enantiomers in human urine without pretreatment of any kind. Using the well-known anti-inflammatory chemical ibuprofen as one example, we demonstrate that the enantiomers of ibuprofen and the diastereoisomers of one of its main metabolites, the glucuronidated carboxylate derivative, can be resolved by (1)H NMR spectroscopy as a consequence of direct addition of the chiral cosolvating agent (CSA) ß-cyclodextrin (ßCD). This approach is simple, rapid, and robust, involves minimal sample manipulation, and does not require derivatization or purification of the sample. In addition, the method should allow the enantiodifferentiation of endogenous chiral metabolites, and this has potential value for differentiating metabolites from mammalian and microbial sources in biofluids. From these initial findings, we propose that more extensive and detailed enantiospecific metabolic profiling could be possible using CSA-NMR spectroscopy than has been previously reported.


Asunto(s)
Antiinflamatorios no Esteroideos/orina , Ibuprofeno/orina , Espectroscopía de Resonancia Magnética/métodos , Metabolómica/métodos , beta-Ciclodextrinas/química , Antiinflamatorios no Esteroideos/química , Antiinflamatorios no Esteroideos/metabolismo , Humanos , Ibuprofeno/química , Ibuprofeno/metabolismo , Espectroscopía de Resonancia Magnética/economía , Metabolómica/economía , Estereoisomerismo , Factores de Tiempo
18.
Bioconjug Chem ; 22(12): 2390-4, 2011 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-22043803

RESUMEN

The development of faster and more sensitive detection methods capable of identifying specific bacterial species and strains has remained a longstanding clinical challenge. Thus to date, the diagnosis of bacterial infections continues to rely on the performance of time-consuming microbiological cultures. Here, we demonstrate the use of bioorthogonal chemistry for magnetically labeling specific pathogens to enable their subsequent detection by nuclear magnetic resonance. Antibodies against a bacterial target of interest were first modified with trans-cyclooctene and then coupled to tetrazine-modified magnetic nanoprobes, directly on the bacteria. This labeling method was verified by surface plasmon resonance as well as by highly specific detection of Staphylococcus aureus using a miniaturized diagnostic magnetic resonance system. Compared to other copper-free bioorthogonal chemistries, the cycloaddition reaction reported here displayed faster kinetics and yielded higher labeling efficiency. Considering the short assay times and the portability of the necessary instrumentation, it is feasible that this approach could be adapted for clinical use in resource-limited settings.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Infecciones Estafilocócicas/diagnóstico , Staphylococcus aureus/aislamiento & purificación , Diseño de Equipo , Humanos , Espectroscopía de Resonancia Magnética/economía , Factores de Tiempo
19.
Z Orthop Unfall ; 149(5): 575-81, 2011 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-21984428

RESUMEN

BACKGROUND: The prevalence of spinal symptoms in Western industrialised countries ranges up to 80 %. Back pain ranks second among the most common reasons to seek medical advice. The resulting financial burden on the health-care system is proportional to the subjectively experienced pain. The aim of the present study was to determine whether the use of magnetic resonance therapy alters the duration of sickness absence in patients with discogenic radiculopathy. PATIENTS AND METHOD: In a double-blind prospective randomised study, the use of magnetic resonance therapy for back pain in patients with discogenic radiculopathy was evaluated in the context of health economics. Patients aged 20 to 55 years with lumboischialgia and no indication for surgery were included in the study. The primary variable was the number of days of sickness absence in a study group before and after magnetic field therapy, and in a control group. The number of days of sickness absence was determined on the basis of a pain diary and by telephone inquiry. RESULTS: Patients who were treated with an activated magnetic resonance therapy device had significantly fewer days of sickness absence (p = 0.009) when evaluated by personal telephone calls. The duration of sickness absence before therapy was 14.7 days and that after therapy 5.8 days. In contrast, the days of sickness absence in the control group were 7.6 days before therapy and 13.8 days after therapy. The duration of symptoms was negatively correlated with the days of sickness absence. Patients who reported a burden at work had more days of sickness absence (8.3 days) than those with no burden at work (3.2 days). This correlation does not apply to familial burden. The cost-effectiveness analysis showed different degrees of compensation of the cost of magnetic resonance therapy, depending on the occupational group. Direct and indirect costs of magnetic resonance therapy were compensated by 16.9 fewer days of sickness absence among workers, 11.4 fewer days of sickness absence among employees, and 9.1 fewer days of sickness absence among civil servants. CONCLUSION: Based on the number of days of sickness absence, the study confirmed that a relatively economical alternative technique is able to provide pain relief as well as benefit the health economy. Unemployed patients or patients who have submitted an application for a pension may be problematic because they may not wish to be pronounced healthy by their doctors.


Asunto(s)
Desplazamiento del Disco Intervertebral/complicaciones , Desplazamiento del Disco Intervertebral/rehabilitación , Dolor de la Región Lumbar/rehabilitación , Espectroscopía de Resonancia Magnética/uso terapéutico , Radiculopatía/rehabilitación , Adulto , Austria , Terapias Complementarias/economía , Terapias Complementarias/métodos , Análisis Costo-Beneficio , Evaluación de la Discapacidad , Método Doble Ciego , Femenino , Humanos , Dolor de la Región Lumbar/economía , Espectroscopía de Resonancia Magnética/economía , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Radiculopatía/diagnóstico , Radiculopatía/economía , Rehabilitación Vocacional/economía , Ausencia por Enfermedad , Adulto Joven
20.
Anal Biochem ; 416(2): 234-6, 2011 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-21640698

RESUMEN

Large-scale nuclear magnetic resonance (NMR) tube cleaning is currently a bottleneck in high-throughput NMR ligand affinity screens. Expensive alternatives include discarding the NMR tubes after a single use (~US $2-$8/tube), using commercial NMR tube cleaners (~$15,000), and abandoning NMR tubes for flow probe technology (~$75,000). Instead, we describe a relatively inexpensive (~$400) and easily constructed apparatus that can clean 180 NMR tubes per hour while using a modest amount of solvent. The application of this apparatus significantly shortens the time to recycle NMR tubes while avoiding cross-contamination and tube damage.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Reciclaje/métodos , Solventes/química , Acetona/química , Espectroscopía de Resonancia Magnética/economía , Metanol/química , Ácido Nítrico/química , Reciclaje/economía , Bicarbonato de Sodio/química , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA