Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 727
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38839349

RESUMEN

T-tubes and airway stents are commonly used but have limited effectiveness and frequent complications. A 50-year-old male patient presented with severe tracheal stenosis, affecting an 8.7 cm length of the airway. We employed an innovative approach known as external suspension fixation of tracheal stent using robotic assistance. This method involves surgically attaching the stent to the exterior of the trachea to provide support and stabilize the softened or collapsed tracheal segments. We designed a C-shaped nickel-titanium alloy exterior stent and successfully fixed it using robotic assistance. This intervention effectively restored tracheal function and led to a favorable postoperative recovery. The technique does not affect tracheal membrane function or airway mucociliary clearance. It could potentially be considered as a new option for treating long-segment benign tracheal softening or collapse.


Asunto(s)
Níquel , Diseño de Prótesis , Procedimientos Quirúrgicos Robotizados , Stents , Titanio , Estenosis Traqueal , Humanos , Masculino , Persona de Mediana Edad , Estenosis Traqueal/cirugía , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/etiología , Estenosis Traqueal/fisiopatología , Resultado del Tratamiento , Aleaciones
2.
Einstein (Sao Paulo) ; 22: eRC0659, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38695416

RESUMEN

A female newborn presented with respiratory distress at birth and was diagnosed with congenital tracheal stenosis. The stenosis was positioned at the distal trachea and compromised the carina and the right and left bronchi. She underwent surgical treatment using circulatory life support with veno-arterial peripheral extracorporeal membrane oxygenation, and the airway was reconstructed using the slide tracheoplasty technique to build a neocarina. The patient had an excellent postoperative course, was successfully weaned from extracorporeal membrane oxygenation and invasive ventilation, and was discharged.


Asunto(s)
Bronquios , Oxigenación por Membrana Extracorpórea , Procedimientos de Cirugía Plástica , Tráquea , Estenosis Traqueal , Humanos , Femenino , Estenosis Traqueal/cirugía , Estenosis Traqueal/congénito , Estenosis Traqueal/diagnóstico por imagen , Recién Nacido , Tráquea/cirugía , Tráquea/anomalías , Tráquea/diagnóstico por imagen , Oxigenación por Membrana Extracorpórea/métodos , Bronquios/cirugía , Bronquios/anomalías , Bronquios/diagnóstico por imagen , Procedimientos de Cirugía Plástica/métodos , Resultado del Tratamiento
6.
Laryngoscope ; 134(1): 108-112, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37194663

RESUMEN

OBJECTIVES: Accurate and reproducible measurements of the pediatric airway are critical for diagnostic evaluation and management of subglottic and tracheal stenosis. The endoluminal functional lumen imaging probe (EndoFLIP) is a catheter-based imaging probe which utilizes impedance planimetry to calculate luminal parameters, including cross-sectional area and compliance. Herein, we demonstrate the feasibility of this system for multidimensional evaluation of the pediatric airway. METHODS: 3D-printed pediatric laryngotracheal models were created based on computed tomography scans, then artificially deformed to simulate both circumferential and posterior subglottic stenosis. Two observers made six measurements of the minimum cross-sectional area (MCSA) and length of stenosis of each model with EndoFLIP. Agreement between observer measurements and model dimensions was evaluated using Lin's concordance correlation coefficient; inter-observer reliability was assessed using intraclass correlation. RESULTS: Four models were created: two without pathology (MCSA: 132.4, 44.3 mm2 ) and two with subglottic stenosis (MCSA: 28.7, 59.7 mm2 , stenotic length 27.8, 24.4 mm). Observer measurements of MCSA and length of stenosis demonstrated high concordance with the models (r = 0.99, 0.95, p < 0.001) with a mean error of 4.5% and 18.2% respectively. There was a low coefficient of variation (0.6%-2.8%) for measurements, indicating high precision. Interrater reliability was high for both MCSA and stenotic length (ICC: 0.99, 0.98). CONCLUSIONS: The EndoFLIP system allows for accurate and reproducible measurements of cross-sectional area and stenotic length in pediatric airway models. This method may provide further advantages in the evaluation of airway distensibility, as well as measurements of asymmetric airway pathology. LEVEL OF EVIDENCE: NA Laryngoscope, 134:108-112, 2024.


Asunto(s)
Laringoestenosis , Estenosis Traqueal , Humanos , Niño , Proyectos Piloto , Constricción Patológica , Reproducibilidad de los Resultados , Laringoestenosis/diagnóstico por imagen , Laringoestenosis/patología , Estenosis Traqueal/diagnóstico por imagen
7.
BMJ Case Rep ; 16(12)2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38123324

RESUMEN

Benign airway stenosis often poses a therapeutic challenge and requires a multidisciplinary approach involving interventional pulmonologists and thoracic surgeons. We report the case of a man who presented with thoracic trauma following a road traffic accident. His chest X-ray showed complete collapse of the right lung, while screening flexible bronchoscopy revealed pooled secretions and asymmetric mid-to-lower tracheal stenosis. After thorough clinicoradiological evaluation and multidisciplinary discussion, we proceeded with therapeutic rigid bronchoscopy and silicone stenting of the tracheal stenotic lesion. Post-procedure, the patient improved clinically and also showed radiological improvement. Subsequently, he underwent stent removal and remains in follow-up. While surgery is a definitive modality for management of benign tracheal stenosis, most patients with advanced disease, pneumonia or with poor general condition are unfit to tolerate general anaesthesia or surgery. In such patients, minimally invasive bronchoscopic techniques that are generally safe to perform have led to substantial improvement in symptoms and long-term quality of life.


Asunto(s)
Estenosis Traqueal , Masculino , Humanos , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/etiología , Estenosis Traqueal/cirugía , Siliconas , Calidad de Vida , Broncoscopía , Stents , Estudios Retrospectivos
11.
Laryngoscope ; 133(2): 366-374, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35608335

RESUMEN

OBJECTIVES/HYPOTHESIS: Laryngotracheal stenosis (LTS) is a functionally devastating condition with high respiratory morbidity and mortality. This preliminary study investigates airflow dynamics and stenotic drug delivery in patients with one- and two-level LTS. STUDY DESIGN: A Computational Modeling Restropective Cohort Study. METHODS: Computed tomography scans from seven LTS patients, five with one-level (three subglottic, two tracheal), and two with two-level (glottis + trachea, glottis + subglottis) were used to reconstruct patient-specific three-dimensional upper airway models. Airflow and orally inhaled drug particle transport were simulated using computational fluid dynamics modeling. Drug particle transport was simulated for 1-20 µm particles released into the mouth at velocities of 0 m/s, 1 m/s, 3 m/s, and 10 m/s for metered dose inhaler (MDI) and 0 m/s for dry powder inhaler (DPI) simulations. Airflow resistance and stenotic drug deposition in the patients' airway models were compared. RESULTS: Overall, there was increased airflow resistance at stenotic sites in subjects with two-level versus one-level stenosis (0.136 Pa s/ml vs. 0.069 Pa s/ml averages). Subjects with two-level stenosis had greater particle deposition at sites of stenosis compared to subjects with one-level stenosis (average deposition 2.31% vs. 0.96%). One-level stenosis subjects, as well as one two-level stenosis subject, had the greatest deposition using MDI with a spacer (0 m/s): 2.59% and 4.34%, respectively. The second two-level stenosis subject had the greatest deposition using DPI (3.45%). Maximum deposition across all stenotic subtypes except one-level tracheal stenosis was achieved with particle sizes of 6-10 µm. CONCLUSIONS: Our results suggest that patients with two-level LTS may experience a more constricted laryngotracheal airflow profile compared to patients with one-level LTS, which may enhance overall stenotic drug deposition. LEVEL OF EVIDENCE: NA Laryngoscope, 133:366-374, 2023.


Asunto(s)
Laringoestenosis , Estenosis Traqueal , Humanos , Administración por Inhalación , Estudios de Cohortes , Constricción Patológica , Laringoestenosis/diagnóstico por imagen , Laringoestenosis/tratamiento farmacológico , Pulmón , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/tratamiento farmacológico , Sistemas de Liberación de Medicamentos , Tomografía Computarizada por Rayos X
13.
Pediatr Pulmonol ; 58(1): 230-238, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36208011

RESUMEN

OBJECTIVES: Congenital laryngotracheal stenosis is rare, potentially severe, and difficult to manage. Heliox is a medical gas effective in obstructive airway pathologies, given its physical properties. This study aims to model the interest of Heliox in reducing the respiratory work in congenital laryngotracheal stenosis, using numerical fluid flow simulations, before considering its clinical use. DESIGN: This is a retrospective study, performing Computational Fluid Dynamics numerical simulations of the resistances to airflow and three types of Heliox, on 3D reconstructions from CT scans of children presenting with laryngotracheal stenosis. PATIENTS: Infants and children who were managed in the Pediatric ENT department of a tertiary-care center and underwent CT scanning for laryngotracheal stenosis between 2008 and 2018 were included. RESULTS: Fourteen models of congenital laryngotracheal stenosis were performed in children aged from 16 days to 5 years, and one model of the normal trachea in a 5-year-old child. Tightest stenosis obtained the highest airway resistances, ranging from 40 to 10 kPa/L/s (up to 800 times higher than in the normal case). Heliox enabled a decrease in pressure drops and airway resistances in all stenosis cases, correlated to increasing Helium concentration. CONCLUSIONS: Heliox appears to reduce pressure drops and airway resistances in 3D models of laryngotracheal stenosis. It may represent a supportive treatment for laryngotracheal stenosis, while waiting for specialized care, thanks to the reduction of respiratory work.


Asunto(s)
Laringoestenosis , Estenosis Traqueal , Lactante , Humanos , Niño , Preescolar , Helio/uso terapéutico , Estudios Retrospectivos , Constricción Patológica/terapia , Laringoestenosis/terapia , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/terapia , Oxígeno
14.
J Thorac Cardiovasc Surg ; 166(2): 317-324.e1, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36528435

RESUMEN

OBJECTIVE: This study aimed to investigate surgical outcomes of pulmonary artery (PA) sling without tracheoplasty. METHODS: From 2001 through 2020, among 22 patients who underwent PA sling repair, all but 1 patient who underwent concomitant tracheal surgery were analyzed. The outcomes of interest were all-cause death, PA reintervention, tracheal intervention, and readmission for respiratory symptoms. Computed tomography was used to measure the narrowest tracheal diameter. RESULTS: The median age and weight at repair were 7.6 months and 7.7 kg, respectively. Most patients (20 out of 21, 95.2%) had preoperative respiratory symptoms. Associated airway anomalies included tracheal ring in 12 (57.1%), bridging bronchus in 8 (38.1%), and tracheal bronchus in 2 patients (9.5%). There was 1 in-hospital death (4.8%). The median ventilator time and intensive care unit stay were 23 hours and 3 days, respectively. There was neither late death nor tracheal intervention during follow-up. Five patients (25.0%) underwent reintervention for left PA stenosis. Hospital readmission for respiratory symptom was required in 7 patients and was associated with the narrowest preoperative tracheal diameter (P = .025) and cardiopulmonary bypass time (P = .040) in univariable analysis. The narrowest tracheal diameter of 3.4 mm was identified as a cutoff value for readmission for respiratory symptom. Freedom from readmission for respiratory symptom was 63.3% at 10 years. CONCLUSIONS: PA sling repair without tracheal surgery might be a reasonable surgical option with rare need for tracheal intervention. Hospital readmissions for respiratory symptoms are more frequently required in patients with smaller tracheal diameter and all readmissions were limited to within 2 years after repair.


Asunto(s)
Cardiopatías Congénitas , Estenosis Traqueal , Malformaciones Vasculares , Humanos , Lactante , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Arteria Pulmonar/anomalías , Mortalidad Hospitalaria , Resultado del Tratamiento , Estudios Retrospectivos , Cardiopatías Congénitas/cirugía , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/cirugía , Tráquea/diagnóstico por imagen , Tráquea/cirugía
16.
Pediatr Surg Int ; 38(12): 1769-1776, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36104600

RESUMEN

PURPOSE: The severity of congenital tracheal stenosis (CTS) is commonly evaluated based on the degree of stenosis. However, it does not always reflect the clinical respiratory status. We applied computational fluid dynamics (CFD) to the assessment of CTS. The aim of this study was to evaluate its validity. METHODS: CFD models were constructed on 15 patients (12 preoperative models and 15 postoperative models) with CTS before and after surgery, using the computed tomographic data. Energy flux, needed to drive airflow, measured by CFD and the minimum cross-sectional area of the trachea (MCAT) were quantified and evaluated retrospectively. RESULTS: The energy flux correlated positively with the clinical respiratory status before and after surgery (rs = 0.611, p = 0.035 and rs = 0.591, p = 0.020, respectively). Although MCAT correlated negatively with the clinical respiratory status before surgery (rs = -0.578, p = 0.044), there was not significant correlation between the two after surgery (p = 0.572). CONCLUSIONS: The energy flux measured by CFD assessment reflects the respiratory status in CTS before and after surgery. CFD can be an additional objective and quantitative evaluation tool for CTS.


Asunto(s)
Procedimientos de Cirugía Plástica , Estenosis Traqueal , Humanos , Lactante , Tráquea/cirugía , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/cirugía , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/cirugía , Hidrodinámica , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos de Cirugía Plástica/métodos
17.
Artículo en Chino | MEDLINE | ID: mdl-36058661

RESUMEN

Objective: To compare the accuracy of the centerline extracted based on CT 3D reconstruction and conventional CT 3D reconstruction in measuring the length and degree of laryngotracheal stenosis. Methods: A retrospective analysis was performed on 35 patients with laryngotracheal stenosis (including 19 cases without tracheotomy and 16 cases with tracheotomy) treated in the Department of Otorhinolaryngology Head and Neck Surgery of the First Affiliated Hospital of Guangxi Medical University from March 2006 to March 2016, including 20 males and 15 females, whose ages ranged from 1 to 73 years, with a median age of 40.5 years. And CT data of 20 normal subjects were included in the same period, including 10 males and 10 females, whose ages ranged from 20 to 63 years, with a median age of 37.0 years. The continuous cross-sectional area of the airway perpendicular to the centerline was obtained by Mimics software. The area was compared with the discontinuous cross-sectional areas reconstructed by conventional CT 3D reconstruction software advantage workstation, also the length of cervical trachea, the length of stenosis, and the minimum airway area were compared. Multi-factor linear stepwise regression method was used to analyze the factors influencing the measuring difference between the two methods. Three patients with laryngotracheal stenosis were selected, and the measured stenosis length was compared with the surgical specimens to evaluate the accuracy of the two methods. SPSS 26.0 software was used for statistical analysis. Results: In normal people, the areas of thyroid cartilage notch, glottis, inferio thyroid cartilage margin, inferio cricoid cartilage margin, and suprasternal notch planes measured by Mimics centerline method were smaller than those measured by conventional CT 3D reconstruction (t thyroid cartilage notch=4.685, tglottis=3.791, tlower thyroid cartilage margin=5.621, tlower cricoid cartilage margin=6.312, tsuprasternal notch plane=6.436, P<0.05). And the airway length measured by Mimics centerline method from the inferior thyroid cartilage to the superior sternal notch was longer (t=9.79, P<0.001). In laryngotracheal stenosis, in the non-tracheotomy group, the minimum airway area measured by Mimics centerline method was smaller and the stenosis length was longer than those measured by the conventional CT 3D reconstruction, and the difference was statistically significant (tminimum airway area=2.562, tstenosis length=5.240, P<0.05). In the tracheotomy group, the stenosis length measured by Mimics centerline method was longer than that measured by conventional CT 3D reconstruction, and the difference was statistically significant (tstenosis length=2.854, P<0.05). Multi-factor linear regression analysis showed that different CT thickness had a statistically significant effect on the difference in the length of stenosis measured by the two methods (b=-5.370, t=-3.306, P=0.004), and different tracheal forward angle had a statistically significant effect on the difference in the minimum airway area measured by the two methods (b=-0.419, t=-2.208, P=0.04). The difference between the measured length of the Mimics centerline method and the intraoperative specimens was less than 0.5 mm. Conclusion: The centerline extracted based on CT 3D reconstruction can precisely reflect the laryngotracheal morphology and measure laryngotracheal stenosis more accurately.


Asunto(s)
Laringoestenosis , Estenosis Traqueal , Adolescente , Adulto , Anciano , Niño , Preescolar , China , Constricción Patológica , Femenino , Humanos , Imagenología Tridimensional , Lactante , Laringoestenosis/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/cirugía , Adulto Joven
18.
Contrast Media Mol Imaging ; 2022: 9633527, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36105451

RESUMEN

In order to solve the problem of CT reconstruction imaging, this paper presents a study on the clinical application of preanesthesia in patients with tracheal stenosis. Patients with tracheal stenosis and multislice spiral CT virtual endoscopy (CTVE) were diagnosed, and their application effects were analyzed. Methods. 60 patients with tracheal stenosis were selected for clinical observation. The patients were given tracheal stenosis examination and multislice spiral CT virtual endoscopy. The examination results of the two groups were compared and analyzed by statistical methods. Results. There was no significant difference in the detection rate, sensitivity, accuracy, and specificity between the two groups (P > 0.05). Conclusion. Multislice spiral CT virtual endoscopy combined with a fiberoptic bronchoscope for clinical diagnosis of tracheal stenosis can complement each other. Combined use can effectively improve the detection consistency, and is safe and reliable. It can be used as an effective means for the diagnosis of tracheal stenosis.


Asunto(s)
Anestesia , Estenosis Traqueal , Humanos , Tomografía Computarizada Espiral/métodos , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/cirugía
20.
J Med Case Rep ; 16(1): 129, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35361259

RESUMEN

BACKGROUND: Granulomatosis with polyangiitis is a granulomatous, necrotizing small-vessel vasculitis affecting both children and adults. However, subglottic tracheal stenosis appears more frequently in the pediatric cohort. To date, granulomatosis with polyangiitis is often treated with steroids, cyclophosphamide, azathioprine, or rituximab, but tumor-necrosis-factor-α-antagonistic drugs are increasingly gaining significance in treatment of refractory cases. CASE PRESENTATION: We report the case of a 15-year-old Caucasian male diagnosed with proteinase-3-positive granulomatosis with polyangiitis with acute shortness of breath. X-ray and magnet resonance imaging showed extensive subglottic narrowing. Forced expiratory volume in 1 s was reduced to 50% of age norm, with massively increased effective airway resistance. The patient initially responded very well to high-dose steroids and maintenance therapy with azathioprine. He was subsequently treated with four doses of rituximab, and levels of proteinase 3 antibodies normalized. After 6 months of clinical remission, the patient presented again with acute respiratory symptoms. Again, he was treated with high-dose steroids, but showed poor clinical response this time. Therefore, we decided to commence a tumor-necrosis-factor-α-antagonistic treatment with infliximab, under which our patient achieved clinical remission and normalization of lung function parameters. CONCLUSIONS: The use of tumor-necrosis-factor-α-antagonistic agents might be a promising alternative for the treatment of refractory tracheal stenosis in pediatric patients with granulomatosis with polyangiitis.


Asunto(s)
Granulomatosis con Poliangitis , Estenosis Traqueal , Adolescente , Adulto , Niño , Granulomatosis con Poliangitis/complicaciones , Granulomatosis con Poliangitis/tratamiento farmacológico , Humanos , Infliximab/uso terapéutico , Masculino , Recurrencia , Rituximab/uso terapéutico , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/tratamiento farmacológico , Estenosis Traqueal/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA