Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.473
Filtrar
1.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38823116

RESUMEN

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Asunto(s)
Fascículo Atrioventricular , Humanos , Fascículo Atrioventricular/fisiopatología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Cardioversión Eléctrica/métodos , Ventrículos Cardíacos/fisiopatología , Modelos Cardiovasculares
2.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38753644

RESUMEN

AIMS: Monitoring current of injury (COI) during left bundle branch area pacing (LBBAP) implantation is useful to evaluate lead depth. Technical aspects for recording COI amplitude have not been well studied. Our aims were to evaluate the impact of high-pass filter settings on electrogram recordings during LBBAP implantation. METHODS AND RESULTS: Consecutive patients with successful LBBAP implantation had unipolar recordings of COI at final lead position at different high-pass filter settings (0.01-1 Hz) from the tip electrode during sensing and pacing, and from the ring electrode during sensing. Duration of saturation-induced signal loss was also measured at each filter setting. COI amplitudes were compared between lumenless and stylet-driven leads. A total of 156 patients (96 males, aged 81.4 ± 9.6 years) were included. Higher filter settings led to significantly lower COI amplitudes. In 50 patients with COI amplitude < 10 mV, the magnitude of the drop was on average 1-1.5 mV (and up to 4 mV) between 0.05 and 0.5 Hz, meaning that cut-offs may not be used interchangeably. Saturation-induced signal loss was on average 10 s at 0.05 Hz and only 2 s with 0.5 Hz. When pacing was interrupted, the sensed COI amplitude varied (either higher or lower) by up to 4 mV, implying that it is advisable to periodically interrupt pacing to evaluate the sensed COI when reaching levels of ∼10 mV. Lead type did not impact COI amplitude. CONCLUSION: High-pass filters have a significant impact on electrogram characteristics at LBBAP implantation, with the 0.5 Hz settings having the most favourable profile.


Asunto(s)
Estimulación Cardíaca Artificial , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Técnicas Electrofisiológicas Cardíacas , Fascículo Atrioventricular/fisiopatología , Marcapaso Artificial , Diseño de Equipo , Resultado del Tratamiento , Potenciales de Acción
3.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703372

RESUMEN

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Asunto(s)
Estimulación Cardíaca Artificial , Humanos , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Estimulación Cardíaca Artificial/métodos , Tabique Interventricular/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Resultado del Tratamiento , Factores de Riesgo , Fascículo Atrioventricular/fisiopatología , Tabiques Cardíacos/diagnóstico por imagen , Medios de Contraste , Fluoroscopía , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/etiología
4.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38563226

RESUMEN

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Asunto(s)
Fascículo Atrioventricular , Ramos Subendocárdicos , Humanos , Electrocardiografía/métodos , Estimulación Cardíaca Artificial/métodos
8.
J Cardiovasc Med (Hagerstown) ; 25(6): 450-456, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38625833

RESUMEN

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P  = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P  < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P  < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Anciano de 80 o más Años , Anciano , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Resultado del Tratamiento , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular/fisiopatología , Factores de Tiempo , Letonia , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Frecuencia Cardíaca
9.
Heart Rhythm ; 21(6): 874-880, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38428448

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Puntaje de Propensión , Sistema de Registros , Volumen Sistólico , Humanos , Masculino , Femenino , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Estudios Prospectivos , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Volumen Sistólico/fisiología , Resultado del Tratamiento , Fascículo Atrioventricular/fisiopatología , Estudios de Seguimiento , Función Ventricular Izquierda/fisiología
10.
Cardiovasc Pathol ; 70: 107626, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38458505

RESUMEN

Iatrogenic damage to the cardiac conduction system (CCS) remains a significant risk during congenital heart surgery. Current surgical best practice involves using superficial anatomical landmarks to locate and avoid damaging the CCS. Prior work indicates inherent variability in the anatomy of the CCS and supporting tissues. This study introduces high-resolution, 3D models of the CCS in normal pediatric human hearts to evaluate variability in the nodes and surrounding structures. Human pediatric hearts were obtained with an average donor age of 2.7 days. A pipeline was developed to excise, section, stain, and image atrioventricular (AVN) and sinus nodal (SN) tissue regions. A convolutional neural network was trained to enable precise multi-class segmentation of whole-slide images, which were subsequently used to generate high- resolution 3D tissue models. Nodal tissue region models were created. All models (10 AVN, 8 SN) contain tissue composition of neural tissue, vasculature, and nodal tissues at micrometer resolution. We describe novel nodal anatomical variations. We found that the depth of the His bundle in females was on average 304 µm shallower than those of male patients. These models provide surgeons with insight into the heterogeneity of the nodal regions and the intricate relationships between the CCS and surrounding structures.


Asunto(s)
Nodo Atrioventricular , Imagenología Tridimensional , Humanos , Femenino , Masculino , Recién Nacido , Nodo Atrioventricular/anatomía & histología , Modelos Cardiovasculares , Nodo Sinoatrial/anatomía & histología , Fascículo Atrioventricular/fisiopatología , Redes Neurales de la Computación , Factores Sexuales , Factores de Edad , Sistema de Conducción Cardíaco/fisiopatología
11.
Pacing Clin Electrophysiol ; 47(4): 525-532, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38430478

RESUMEN

INTRODUCTION: The optimal slow pathway (SP) ablation site in cases with an inferiorly located His bundle (HIS) remains unclear. METHODS AND RESULTS: In 45 patients with atrioventricular nodal reentrant tachycardia, the relationship between the HIS location and successful SP ablation site was assessed in electroanatomical maps. We assessed the location of the SP ablation site relative to the bottom of the coronary sinus ostium in the superior-to-inferior (SPSI), anterior-to-posterior (SPAP), and right-to-left (SPRL) directions. The HIS location was assessed in the same manner. The HIS location in the superior-to-inferior direction (HISSI), SPSI, SPAP, and SPRL were 17.7 ± 6.4, 1.7 ± 6.4, 13.6 ± 12.3, and -1.0 ± 13.0 mm, respectively. The HISSI was positively correlated with SPSI (R2 = 0.62; P < .01) and SPAP (R2 = 0.22; P < .01), whereas it was not correlated with SPRL (R2 = 0.01; P = .65). The distance between the HIS and SP ablation site was 17.7 ± 6.4 mm and was not affected by the location of HIS. The ratio of the amplitudes of atrial and ventricular potential recorded at the SP ablation site did not differ between the high HIS group (HISSI ≥ 13 mm) and low HIS group (HISSI < 13 mm) (0.10 ± 0.06 vs. 0.10 ± 0.06; P = .38). CONCLUSION: In cases with an inferiorly located HIS, SP ablation should be performed at a lower and more posterior site than in typical cases.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Tabique Interventricular , Humanos , Fascículo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Ventrículos Cardíacos , Atrios Cardíacos
14.
J Cardiovasc Electrophysiol ; 35(4): 846-847, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38348495

RESUMEN

The year 2024 marks the centenary of Mobitz's description of type II second-degree atrioventricular block. Its definition remains valid to this day with only minor modification for the diagnosis of infranodal conduction block. Mobitz a century ago indicated that his type II atrioventricular block was associated with Stock-Adams attacks and a prolonged duration of the QRS complex before the eventual description of bundle branch block.


Asunto(s)
Bloqueo Atrioventricular , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Electrocardiografía , Bloqueo de Rama/diagnóstico , Fascículo Atrioventricular
15.
J Cardiovasc Electrophysiol ; 35(4): 727-736, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38351331

RESUMEN

INTRODUCTION: Clinical outcomes of long-term ventricular septal pacing (VSP) without His-Purkinje capture remain unknown. This study evaluated the differences in clinical outcomes between conduction system pacing (CSP), VSP, and right ventricular pacing (RVP). METHODS: Consecutive patients with bradycardia indicated for pacing from 2016 to 2022 were prospectively followed for the clinical endpoints of heart failure (HF)-hospitalizations and all-cause mortality at 2 years. VSP was defined as septal pacing due to unsuccessful CSP implant or successful CSP followed by loss of His-Purkinje capture within 90 days. RESULTS: Among 1016 patients (age 73.9 ± 11.2 years, 47% female, 48% atrioventricular block), 612 received RVP, 335 received CSP and 69 received VSP. Paced QRS duration was similar between VSP and RVP, but both significantly longer than CSP (p < .05). HF-hospitalizations occurred in 130 (13%) patients (CSP 7% vs. RVP 16% vs. VSP 13%, p = .001), and all-cause mortality in 143 (14%) patients (CSP 7% vs. RVP 19% vs. VSP 9%, p < .001). The association of pacing modality with clinical events was limited to those with ventricular pacing (Vp) > 20% (pinteraction < .05). Adjusting for clinical risk factors among patients with Vp > 20%, VSP (adjusted hazard ratio [AHR]: 4.74, 95% confidence interval [CI]: 1.57-14.36) and RVP (AHR: 3.08, 95% CI: 1.44-6.60) were associated with increased hazard of HF-hospitalizations, and RVP (2.52, 95% CI: 1.19-5.35) with increased mortality, compared to CSP. Clinical endpoints did not differ between VSP and RVP with Vp > 20%, or amongst groups with Vp < 20%. CONCLUSION: Conduction system capture is associated with improved clinical outcomes. CSP should be preferred over VSP or RVP during pacing for bradycardia.


Asunto(s)
Insuficiencia Cardíaca , Marcapaso Artificial , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/etiología , Pronóstico , Estimulación Cardíaca Artificial/efectos adversos , Trastorno del Sistema de Conducción Cardíaco , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Fascículo Atrioventricular , Electrocardiografía , Resultado del Tratamiento
16.
J Am Heart Assoc ; 13(4): e032386, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38348809

RESUMEN

BACKGROUND: Metabolic disorder is noted for pacing-induced cardiomyopathy. The benefits of His bundle pacing over right ventricular (RV) pacing in preventing pacing-induced cardiomyopathy from a metabolic perspective are yet to be fully understood. METHOD AND RESULTS: Three pig groups were established for this study: sham control, RV pacing (RV pacing for 6 months), and His pacing (RV pacing for 6 months, followed by His bundle pacing for 3 months). Complete atrioventricular block was created in the last 2 groups. Left ventricular function and dyssynchrony were assessed via echocardiography, while proteins linked to metabolism, endoplasmic reticulum stress, and inflammation in left ventricular myocardium were examined. The RV pacing group had significantly more left ventricular mechanical dyssynchrony compared with the other groups. The RV pacing group exhibited triglyceride and diacylglycerol accumulation in cardiomyocytes and higher expression of binding immunoglobulin protein and tumor necrosis factor-α than the other groups. Additionally, the expression of CD36 was activated, while the expression of hormone-sensitive lipase was downregulated in the RV pacing group compared with the His pacing and sham control groups. Furthermore, the expressions of GLUT4 and pyruvate dehydrogenase were higher in the RV pacing group than the sham control and His pacing groups. Notably, the abnormal fatty acid and glucose metabolic pathways in the left ventricular myocardium during RV pacing could be corrected by His bundle pacing. CONCLUSIONS: His bundle pacing can mitigate the abnormal metabolism disorders, endoplasmic reticulum stress, and inflammation induced during RV pacing and may contribute to the superiority of conduction system pacing over RV pacing in reducing heart failure hospitalization.


Asunto(s)
Fascículo Atrioventricular , Cardiomiopatías , Animales , Porcinos , Miocardio , Ventrículos Cardíacos , Glucosa , Inflamación , Estimulación Cardíaca Artificial/métodos , Electrocardiografía
17.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 68-76, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38424340

RESUMEN

The first permanent biventricular pacing system was implanted more than 30 years ago. In this article, the historical development of cardiac resynchronization therapy (CRT), starting with the pathophysiological concept, followed by the initial "proof of concept" studies and finally the large prospective-randomized studies that led to the implementation of CRT in heart failure guidelines, is outlined. Since the establishment of CRT, both an expansion of indications, e.g., for patients with mild heart failure and atrial fibrillation, but also the return to patients with broad QRS complex and left bundle branch block who benefit most of CRT has evolved. New techniques such as conduction system pacing will have major influence on pacemaker therapy in heart failure, both as an alternative or adjunct to CRT.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Fascículo Atrioventricular , Estudios Prospectivos , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia
20.
J Cardiovasc Electrophysiol ; 35(5): 875-882, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38424662

RESUMEN

INTRODUCTION: Left bundle branch pacing (LBBP) is a physiological pacing modality. However, the long procedure and fluoroscopy time of LBBP is still a problem. This study aims to compare the clinical outcomes between transthoracic echocardiography (TTE)- and X-ray-guided LBBP. METHODS: This is a single-center, prospective, randomized controlled study. Consecutive patients who underwent LBBP in our team from June 2022 to November 2022 were enrolled. Procedure and fluoroscopy time, pacing parameters, electrophysiological and echocardiographic characteristics, as well as complications were recorded at implantation and during follow-up. RESULTS: In this study, 60 patients were enrolled and divided into two groups: 30 patients were allocated to the X-ray group and the remaining 30 to the TTE group. There was no significant difference in the success rate between the two groups (86.7% vs. 76.7%, p = .317). The procedure time of TTE group was comparable to that of the X-ray group (9.0 vs. 12.0 min, p = .063). However, the fluoroscopy time in the TTE group was significantly lower than that of the X-ray group (2.5 vs. 5.0 min, p = .002). There were no statistically significant differences in pacing parameters, electrophysiological and echocardiographic characteristics, or complications between the two groups at implantation and during follow-up. CONCLUSION: TTE-guided LBBP is a feasible and safe method. Compared with X-ray, TTE showed a comparable success rate and procedure time, but it could significantly reduce the fluoroscopy time of LBBP.


Asunto(s)
Bradicardia , Estimulación Cardíaca Artificial , Ecocardiografía , Frecuencia Cardíaca , Humanos , Masculino , Femenino , Estudios Prospectivos , Bradicardia/terapia , Bradicardia/fisiopatología , Bradicardia/diagnóstico , Resultado del Tratamiento , Anciano , Persona de Mediana Edad , Factores de Tiempo , Potenciales de Acción , Radiografía Intervencional , Fascículo Atrioventricular/fisiopatología , Valor Predictivo de las Pruebas , Fluoroscopía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA