Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
PLoS One ; 19(6): e0303293, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38865365

RESUMEN

Silica aerogels or xerogels are renowned dried gels with low density, high surface area, higher porosity, and better thermal stability which makes it suitable for aerospace, light weight structures, thermal insulation, and hydrophobic coatings. But brittle behaviour, low mechanical strength, and high manufacturing cost restrict its usage. Recently, the addition of various fibres like glass or carbon fiber is one of the best reinforcement methods to minimize the brittle behaviour. Supercritical drying technique usually used to develop aerogel that is expensive and difficult to produce in bulk quantities. Higher cost obstacle can be tackled by applying ambient pressure drying technique to develop xerogel. But researcher observed cracks in samples prepared through the ambient pressure drying technique is still a major shortcoming. The aim of this study is to systematically analyze the influence of silica gel fiber reinforcement on silica xerogels, encompassing morphology, mechanics, thermal behaviour, compression test, and thermogravimetric characteristics. The research used a low-cost precursor named Tetraethyl orthosilicate to synthesize low-cost composite Silica xerogel and glass and carbon fiber added to provide strength and flexibility to the overall composite. Silica gel works as binder in strengthening the xerogel network. The investigation employs scanning electron microscopy (SEM) to examine the morphology of the composites, Fourier Transform Infrared (FTIR) analysis to affirm hydrophobic characteristics, compression tests to assess mechanical strength, and thermogravimetric tests to study weight loss under different conditions. SEM results reveals that glass fibers exhibit lower adhesion to the xerogel network compared to carbon fibers. FTIR analysis confirms the hydrophobicity of the composite silica xerogel. Compression tests showed that, under a 48% strain rate, the carbon fiber composite demonstrates superior compressive stress endurance. Thermogravimetric tests revealed a 1% lower weight loss for the carbon fiber composite compared to the glass fiber composite. This work concludes that glass and carbon fiber together with silica gel particles successfully facilitated in developing flexible, less costly, hydrophobic, and crack-free silica xerogel composites by APD. These advancements have the potential to drive innovations in material science and technology across diverse industries.


Asunto(s)
Dióxido de Silicio , Dióxido de Silicio/química , Termogravimetría , Geles/química , Gel de Sílice/química , Vidrio/química , Temperatura , Fibra de Carbono/química , Microscopía Electrónica de Rastreo , Porosidad , Ensayo de Materiales , Espectroscopía Infrarroja por Transformada de Fourier
2.
Sci Rep ; 14(1): 13215, 2024 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-38851842

RESUMEN

Using a curved carbon-fiber plate (CFP) in running shoes may offer notable performance benefit over flat plates, yet there is a lack of research exploring the influence of CFP geometry on internal foot loading during running. The objective of this study was to investigate the effects of CFP mechanical characteristics on forefoot biomechanics in terms of plantar pressure, bone stress distribution, and contact force transmission during a simulated impact peak moment in forefoot strike running. We employed a finite element model of the foot-shoe system, wherein various CFP configurations, including three stiffnesses (stiff, stiffer, and stiffest) and two shapes (flat plate (FCFP) and curved plate (CCFP)), were integrated into the shoe sole. Comparing the shoes with no CFP (NCFP) to those with CFP, we consistently observed a reduction in peak forefoot plantar pressure with increasing CFP stiffness. This decrease in pressure was even more notable in a CCFP demonstrating a further reduction in peak pressure ranging from 5.51 to 12.62%, compared to FCFP models. Both FCFP and CCFP designs had a negligible impact on reducing the maximum stress experienced by the 2nd and 3rd metatarsals. However, they greatly influenced the stress distribution in other metatarsal bones. These CFP designs seem to optimize the load transfer pathway, enabling a more uniform force transmission by mainly reducing contact force on the medial columns (the first three rays, measuring 0.333 times body weight for FCFP and 0.335 for CCFP in stiffest condition, compared to 0.373 in NCFP). We concluded that employing a curved CFP in running shoes could be more beneficial from an injury prevention perspective by inducing less peak pressure under the metatarsal heads while not worsening their stress state compared to flat plates.


Asunto(s)
Carrera , Zapatos , Carrera/fisiología , Humanos , Fenómenos Biomecánicos , Presión , Fibra de Carbono/química , Antepié Humano/fisiología , Análisis de Elementos Finitos , Estrés Mecánico , Soporte de Peso/fisiología , Carbono/química , Diseño de Equipo , Pie/fisiología
3.
Int J Biol Macromol ; 273(Pt 2): 132921, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38866281

RESUMEN

In order to investigate the effect of boron element on liquefied wood carbon fibers and their composites, boric acid and boron carbide were utilized to modify liquefied wood resin through copolymerization and blending methods respectively. Then boric acid-modified liquefied wood carbon fiber (BA-WCF) and boron carbide-modified liquefied wood carbon fiber (BC-WCF) were produced via melt spinning, curing, and carbonization treatments. As expected, this modification approach effectively prevents the formation of skin-core structures and accelerates the evolution of a graphite microcrystalline structure, thereby enhancing the mechanical properties of the carbon fibers. Particularly, the tensile strength and elongation at break of BA-WCF increased to 331.57 MPa and 7.57 % respectively, representing increments of 117 % and 86 % compared to the conventional fibers. Furthermore, the as-fabricated carbon fiber/resin composites (CFPRs), composing of BA-WCF or BC-WCF as fillers and liquefied wood resin as matrix, exhibited excellent interlaminar shear strength, outstanding abrasion resistance, and well thermal conductivity, as well as electrical performance, significantly outperforming the conventional carbon fiber/phenolic resin composites. The friction rate of BC-WP/BA-WCF/CF was 2.37 %, while its thermal conductivity could reach 1.927 W/(m·K). These promising attributes lay the groundwork for the development of high-performance carbon fiber-based materials, fostering their widespread utilization across various industries.


Asunto(s)
Fibra de Carbono , Conductividad Térmica , Madera , Fibra de Carbono/química , Madera/química , Catálisis , Resistencia a la Tracción , Compuestos de Boro/química , Ácidos Bóricos
4.
J Nanobiotechnology ; 22(1): 377, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937768

RESUMEN

BACKGROUND: Efficient monitoring of glucose concentration in the human body necessitates the utilization of electrochemically active sensing materials in nonenzymatic glucose sensors. However, prevailing limitations such as intricate fabrication processes, lower sensitivity, and instability impede their practical application. Herein, ternary Cu-Co-Ni-S sulfides nanoporous network structure was synthesized on carbon fiber paper (CP) by an ultrafast, facile, and controllable technique through on-step cyclic voltammetry, serving as a superior self-supporting catalytic electrode for the high-performance glucose sensor. RESULTS: The direct growth of free-standing Cu-Co-Ni-S on the interconnected three-dimensional (3D) network of CP boosted the active site of the composites, improved ion diffusion kinetics, and significantly promoted the electron transfer rate. The multiple oxidation states and synergistic effects among Co, Ni, Cu, and S further promoted glucose electrooxidation. The well-architected Cu-Co-Ni-S/CP presented exceptional electrocatalytic properties for glucose with satisfied linearity of a broad range from 0.3 to 16,000 µM and high sensitivity of 6829 µA mM- 1 cm- 2. Furthermore, the novel sensor demonstrated excellent selectivity and storage stability, which could successfully evaluate the glucose levels in human serum. Notably, the novel Cu-Co-Ni-S/CP showed favorable biocompatibility, proving its potential for in vivo glucose monitoring. CONCLUSION: The proposed 3D hierarchical morphology self-supported electrode sensor, which demonstrates appealing analysis behavior for glucose electrooxidation, holds great promise for the next generation of high-performance glucose sensors.


Asunto(s)
Técnicas Biosensibles , Fibra de Carbono , Cobalto , Cobre , Técnicas Electroquímicas , Electrodos , Níquel , Sulfuros , Cobre/química , Níquel/química , Catálisis , Humanos , Cobalto/química , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/métodos , Sulfuros/química , Fibra de Carbono/química , Glucosa/análisis , Glucosa/química , Nanoporos , Oxidación-Reducción , Glucemia/análisis
5.
PLoS One ; 19(6): e0304797, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38829883

RESUMEN

Partially encased concrete (PEC) has better mechanical properties as a structure where steel and concrete work together. Due to the increasing amount of construction waste, recycled aggregate concrete (RAC) is being considered by more people. However, although RAC has more points, the performance is inferior to natural aggregate concrete (NAC). To narrow or address this gap, lightweight, high-strength and corrosion-resistant CFRP can be used, also protecting the steel flange of the PEC structure. Therefore, carbon fiber reinforced polymer (CFRP) confined partially encased recycled coarse aggregate concrete columns were studied in this paper. With respect to different slenderness ratios, recycled coarse aggregate(RCA) replacement ratios, and number of CFRP layers, the performance of the proposed CFRP restrained columns are reported. The RCA replacement ratio is analyzed to be limited negative impact on the bearing capacity, generally within 6%. As for the slenderness ratio, the bearing capacity increased with it. However, wrapping CFRP significantly increased the bearing capacity. Considering the arch factor, a simple formula for calculating the ultimate strength of CFRP-confined partially encased RAC columns is developed based on EC4 and GB50017-2017. By comparison with the experimental values, the error is within 10%.


Asunto(s)
Fibra de Carbono , Fuerza Compresiva , Materiales de Construcción , Polímeros , Reciclaje , Fibra de Carbono/química , Materiales de Construcción/análisis , Polímeros/química , Ensayo de Materiales , Acero/química
6.
ACS Sens ; 9(5): 2662-2672, 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38689483

RESUMEN

Dopamine (DA) signaling is critically important in striatal function, and this metabolically demanding process is fueled largely by glucose. However, DA and glucose are typically studied independently and, as such, the precise relationship between DA release and glucose availability remains unclear. Fast-scan cyclic voltammetry (FSCV) is commonly coupled with carbon-fiber microelectrodes to study DA transients. These microelectrodes can be modified with glucose oxidase (GOx) to generate microbiosensors capable of simultaneously quantifying real-time and physiologically relevant fluctuations of glucose, a nonelectrochemically active substrate, and DA, which is readily oxidized and reduced at the electrode surface. A chitosan hydrogel can be electrodeposited to entrap the oxidase enzyme on the sensor surface for stable, sensitive, and selective codetection of glucose and DA using FSCV. This strategy can also be used to entrap lactate oxidase on the carbon-fiber surface for codetection of lactate and DA. However, these custom probes are individually fabricated by hand, and performance is variable. This study characterizes the physical nature of the hydrogel and its effects on the acquired electrochemical data in the detection of glucose (2.6 mM) and DA (1 µM). The results demonstrate that the electrodeposition of the hydrogel membrane is improved using a linear potential sweep rather than a direct step to the target potential. Electrochemical impedance spectroscopy data relate information on the physical nature of the electrode/solution interface to the electrochemical performance of bare and enzyme-modified carbon-fiber microelectrodes. The electrodeposition waveform and scan rate were characterized for optimal membrane formation and performance. Finally, codetection of both DA/glucose and DA/lactate was demonstrated in intact rat striatum using probes fabricated according to the optimized protocol. Overall, this work improves the reliable fabrication of carbon-fiber microbiosensors for codetection of DA and important energetic substrates that are locally delivered to the recording site to meet metabolic demand.


Asunto(s)
Técnicas Biosensibles , Fibra de Carbono , Dopamina , Glucosa Oxidasa , Glucosa , Microelectrodos , Dopamina/análisis , Glucosa/análisis , Fibra de Carbono/química , Técnicas Biosensibles/métodos , Glucosa Oxidasa/química , Glucosa Oxidasa/metabolismo , Animales , Carbono/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Hidrogeles/química , Ratas , Ratas Sprague-Dawley , Encéfalo/metabolismo , Quitosano/química , Oxigenasas de Función Mixta/química , Oxigenasas de Función Mixta/metabolismo , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo
7.
ACS Appl Mater Interfaces ; 16(23): 29728-29736, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38804619

RESUMEN

Methionine-enkephalin (Met-Enk) is an endogenous opioid peptide that is involved in various physiological processes including memory. A technological gap in the understanding of Met-Enk's role in memory is the lack of rapid measurement tools to selectively quantify Met-Enk concentrations in situ. Here, we integrate molecularly imprinted polymers (MIPs) with carbon fiber microelectrodes (CFMs) to selectively detect Met-Enk by using fast-scan cyclic voltammetry (FSCV). We report two MIP conditions that yield 2-fold and 5-fold higher selectivity toward Met-Enk than the tyrosine-containing hexapeptide fragment angiotensin II (3-8). We demonstrate that MIP technology can be combined with FSCV at CFMs to create rapid and selective sensors for Met-Enk. This technology is a promising platform for creating selective sensors for other peptides and biomarkers.


Asunto(s)
Fibra de Carbono , Técnicas Electroquímicas , Encefalina Metionina , Microelectrodos , Fibra de Carbono/química , Encefalina Metionina/análisis , Encefalina Metionina/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Impresión Molecular , Polímeros Impresos Molecularmente/química , Carbono/química
8.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795258

RESUMEN

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Asunto(s)
Benzofenonas , Coronas , Pilares Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Titanio , Circonio , Cetonas/química , Polietilenglicoles/química , Humanos , Circonio/química , Titanio/química , Fibra de Carbono/química , Diseño de Implante Dental-Pilar , Incisivo , Materiales Dentales/química , Implantes Dentales de Diente Único , Hueso Cortical , Vidrio/química , Diseño de Prótesis Dental
9.
Anal Chem ; 96(25): 10322-10331, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38801718

RESUMEN

The chemical information on brain science provided by electrochemical sensors is critical for understanding brain chemistry during physiological and pathological processes. A major challenge is the selectivity of electrochemical sensors in vivo. This work developed a universal covalent grafting strategy of an aptamer on a carbon fiber microelectrode (CFE) for selective determination of dopamine in vivo. The universal strategy was proposed by oxidizing poly(tannic acid) (pTA) to form an oxidized state (pTAox) and then coupling a nucleophilic sulfhydryl molecule of the dopamine-binding mercapto-aptamer with the o-quinone moiety of pTAox based on click chemistry for the interfacial functionalization of the CFE surface. It was found that the universal strategy proposed could efficiently graft the aptamer on a glassy carbon electrode, which was verified by using electroactive 6-(ferrocenyl) hexanethiol as a redox reporter. The amperometric method using a fabricated aptasensor for the determination of dopamine was developed. The linear range of the aptasensor for the determination of dopamine was 0.2-20 µM with a sensitivity of 0.09 nA/µM and a limit of detection of 88 nM (S/N = 3). The developed method has high selectivity originating from the specific recognition of the aptamer in concert with the cation-selective action of pTA and could be easily applicable to probe dopamine dynamics in the brain. Furthermore, complex vesicle fusion modes were first observed at the animal level. This work demonstrated that the covalently grafted immobilization strategy proposed is promising and could be extended to the in vivo analysis of other neurochemicals.


Asunto(s)
Aptámeros de Nucleótidos , Fibra de Carbono , Dopamina , Microelectrodos , Dopamina/análisis , Aptámeros de Nucleótidos/química , Fibra de Carbono/química , Animales , Técnicas Electroquímicas/métodos , Carbono/química , Ratas , Técnicas Biosensibles/métodos , Masculino , Oxidación-Reducción
10.
ACS Sens ; 9(5): 2346-2355, 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38713172

RESUMEN

Dopamine (DA) and serotonin (5-HT) are neurotransmitters that regulate a wide range of physiological and behavioral processes. Monitoring of both neurotransmitters with real-time analysis offers important insight into the mechanisms that shape animal behavior. However, bioelectronic tools to simultaneously monitor DA and 5-HT interactive dynamics in freely moving animals are underdeveloped. This is mainly due to the limited sensor sensitivity with miniaturized electronics. Here, we present a semi-implantable electrochemical device achieved by integrating a multi-surface-modified carbon fiber microelectrode with a miniaturized potentiostat module to detect DA and 5-HT in vivo with high sensitivity and selectivity. Specifically, carbon fiber microelectrodes were modified through electrochemical treatment and surface coatings to improve sensitivity, selectivity, and antifouling properties. A customized, lightweight potentiostat module was developed for untethered electrochemical measurements. Integrated with the microelectrode, the microsystem is compact (2.8 × 2.3 × 2.1 cm) to minimize its impacts on animal behavior and achieved simultaneous detection of DA and 5-HT with sensitivities of 48.4 and 133.0 nA/µM, respectively, within submicromolar ranges. The system was attached to the crayfish dorsal carapace, allowing electrode implantation into the heart of a crayfish to monitor DA and 5-HT dynamics, followed by drug injections. The semi-implantable biosensor system displayed a significant increase in oxidation peak currents after DA and 5-HT injections. The device successfully demonstrated the application for in vivo simultaneous monitoring of DA and 5-HT in the hemolymph (i.e., blood) of freely behaving crayfish underwater, yielding a valuable experimental tool to expand our understanding of the comodulation of DA and 5-HT.


Asunto(s)
Astacoidea , Dopamina , Técnicas Electroquímicas , Microelectrodos , Serotonina , Animales , Dopamina/análisis , Serotonina/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Tecnología Inalámbrica , Fibra de Carbono/química , Técnicas Biosensibles/métodos
11.
Waste Manag ; 184: 28-36, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38795538

RESUMEN

Carbon fiber-reinforced polymer composites (CFRPs) have gained widespread usage due to their promising physiochemical properties, while this causes large amounts of waste CFRPs worldwide. In this study, carbon fibers were successfully recovered from waste CFRPs through the pyrolysis-oxidation method, and the recovered fibers were reused in remanufacturing the secondary generation CFRPs. Moreover, the individual and interactive effects of pyrolysis-oxidation recovering parameters on the mechanical strength of the resulting remanufactured CFRPs (reCFRPs) were investigated. The recovered carbon fibers displayed surface chemical structures similar to virgin fibers but with high contents of oxygen-containing bonds. The tensile strength retention (TSR) of the reCFRPs was primarily influenced by oxidation temperature. Notably, a higher oxidation temperature, especially exceeding 560 °C, amplified the impact of oxidation duration on the TSR value. Similarly, concerning interlaminar shear strength retention (ISSR), the oxidation stage had a more substantial effect compared to the pyrolysis stage. As the oxidation temperature increased from 500 °C to 600 °C, the ISSR value initially increased and then decreased, irrespective of variations in pyrolysis parameters. Additionally, through integrating the response surface methodology (RSM) analysis and multi-island genetic algorithm (MIGA) global optimization, three recovery strategies, along with the corresponding processing parameters, were proposed to meet diverse requirements. The conclusions could provide valuable insights for optimizing the recovery and reuse of carbon fibers from waste CFRPs.


Asunto(s)
Fibra de Carbono , Oxidación-Reducción , Pirólisis , Reciclaje , Fibra de Carbono/química , Reciclaje/métodos , Resistencia a la Tracción , Polímeros/química , Carbono/química
12.
Int J Biol Macromol ; 270(Pt 2): 132191, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729466

RESUMEN

Obtaining lignin-based graphite-like microcrystallites at a relatively low carbonization temperature is still very challenging. In this work, we report a new method based on condensed structures, for regulating graphite-like microcrystalline structures via the incorporation of 4,4'-diphenylmethane diisocyanate (MDI) into the main structure of lignin. The effects of MDI on the thermal properties of lignin and the graphite-like microcrystalline structure of lignin-based ultrafine carbon fibers were extensively studied and investigated. The incorporation of MDI decreased the thermal stability of lignin, increased the carbon yield and enhanced the formation of graphite-like microcrystallites, which are beneficial for reducing energy consumption during the preparation of lignin-based carbon fibers. The modified lignin-based ultrafine carbon fibers (M-LCFs) demonstrated satisfactory electrochemical performance, including high specific capacitance, low charge transfer resistance, and good cycle performance. The M-LCFs-3/2 electrode had a specific capacitance of 241.3 F g-1 at a current density of 0.5 A g-1, and a residual ratio of 90.2 % after 2000 charge and discharge cycles. This study provides a new approach to control the graphite-like microcrystalline structure and electrochemical performance while also optimizing the temperature.


Asunto(s)
Fibra de Carbono , Grafito , Lignina , Lignina/química , Grafito/química , Fibra de Carbono/química , Cristalización , Temperatura , Capacidad Eléctrica , Electrodos , Carbono/química
13.
Bioresour Technol ; 405: 130907, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38810707

RESUMEN

Coking wastewater contains high concentrations of toxic and low biodegradable organics, causing long hydraulic retention times for its biological treatment process. This study developed a pretreatment method for coking wastewater by using activated carbon fiber (ACF) activated peroxymonosulfate (PMS) to improve the treatment performance of subsequent biological post-treatment process, sequencing batch reactor (SBR). The results showed that, after optimization of treatment processes, the removal efficiency of chemical oxygen demand (COD), phenol, and chroma in coking wastewater reached to 76, 98, and 98%, respectively, with a significantly improved biodegradability. Compared with the sole SBR system without any pretreatment that could remove 73% of COD, the ACF/PMS+SBR system removed over 97% of COD in coking wastewater. Moreover, this pretreatment method facilitated the growth of functional bacteria for organics biodegradation, indicating its high potential as a highly efficacious pretreatment strategy to improve the overall treatment efficiency of coking wastewater.


Asunto(s)
Biodegradación Ambiental , Análisis de la Demanda Biológica de Oxígeno , Reactores Biológicos , Coque , Peróxidos , Aguas Residuales , Aguas Residuales/química , Carbón Orgánico/química , Purificación del Agua/métodos , Fibra de Carbono/química , Carbono/química , Contaminantes Químicos del Agua , Eliminación de Residuos Líquidos/métodos
14.
Int J Biol Macromol ; 271(Pt 2): 132716, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38815941

RESUMEN

Nanoparticle-containing sizing agents are essential for the overall performance of high-quality carbon fiber (CF) composites. However, the uneven dispersion of nanoparticles often leads to agglomeration on the surface of CF after sizing, consequently diminishing the material properties. In this study, the properties of cellulose nanofibers (CNFs) that can respond to magnetic and electric fields were utilized to achieve three-dimensional to one-dimensional orientations in CFs containing sizing agents. Cobalt ferrite (CoFe2O4) was utilized to enhance the response of CNFs to a magnetic field, and subsequently, it was combined with an electric field to attain a higher degree of orientation. The occurrence of nanoparticle agglomeration is diminished on CF surface, while establishing a structured network. The flexural strength and thermal conductivity of CF composites treated with CoFe2O4 self-assembled CNF sizing agent exhibit an increase of 54.23 % and 57.5 %, respectively, compared to those of desized CF composites, when subjected to magnetic and electric fields. Consequently, the approach can depolymerize the nano-fillers within the sizing agent and orient it into the carbon fiber under the influence of magnetic and electric fields, effectively improving the mechanical properties and thermal conductivity of the composite material.


Asunto(s)
Fibra de Carbono , Celulosa , Campos Magnéticos , Nanofibras , Nanofibras/química , Celulosa/química , Fibra de Carbono/química , Compuestos Férricos/química , Cobalto/química , Electricidad , Conductividad Térmica , Nanocompuestos/química
15.
Biosens Bioelectron ; 259: 116365, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38759309

RESUMEN

Effective wound management has the potential to reduce both the duration and cost of wound healing. However, traditional methods often rely on direct observation or complex and expensive biological testing to monitor and evaluate the invasive damage caused by wound healing, which can be time-consuming. Biosensors offer the advantage of precise and real-time monitoring, but existing devices are not suitable for integration with sensitive wound tissue due to their external dimensions. Here, we have designed a self-powered biosensing suture (SPBS) based on biofuel cells to accurately monitor glucose concentration at the wound site and promote wound healing. The anode of the SPBS consists of carbon nanotubes-modified carbon fibers, tetrathiafulvalene (TTF), and glucose oxidase (GOx), while the cathode is composed of Ag2O and carbon nanotubes modified nanotubes modified carbon fibers. It was observed that SPBS exhibited excellent physical and chemical stability in vitro. Regardless of different bending degrees or pH values, the maximum power density of SPBS remained above 92%, which is conducive to long-term dynamic evaluation. Furthermore, the voltage generated by SPBS reflects blood glucose concentration, and measurements at wound sites are consistent with those obtained using a commercially available blood glucose meter. SPBS achieves the healing effect of traditional medical sutures after complete healing within 14 days. It offers valuable insights for intelligent devices dedicated to real-time wound monitoring.


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Suturas , Cicatrización de Heridas , Técnicas Biosensibles/instrumentación , Nanotubos de Carbono/química , Humanos , Glucosa Oxidasa/química , Diseño de Equipo , Fuentes de Energía Bioeléctrica , Glucemia/análisis , Animales , Glucosa/análisis , Glucosa/aislamiento & purificación , Fibra de Carbono/química
16.
Biomater Adv ; 161: 213888, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759305

RESUMEN

Short carbon fiber (SCF) reinforced polymer composites are expected to possess outstanding biotribological and mechanical properties in certain direction, while the non-oriented SCF weakens its reinforcing effect in the matrix. In this work, high-oriented SCF was achieved during nozzle extrusion, and then SCF reinforced polyether-ether-ketone (PEEK) composites were fabricated by fused deposition modeling (FDM). The concrete orientation process of SCF was theoretically simulated, and significant shear stress difference was generated at both ends of SCF. As a result, the SCF was distributed in the matrix in a hierarchical structure, containing surface layer I, II and core layer. Moreover, the SCF was oriented highly along the printing direction and demonstrated a more competitive orientation distribution compared to other studies. The SCF/PEEK composites showed a considerable improvement in wear resistance by 44 % due to self-lubricating and load-bearing capability of SCF. Besides, it demonstrated enhancements in Brinell hardness, compressive and impact strength by 48.52 %, 16.42 % and 53.64 %, respectively. In addition, SCF/PEEK composites also showed good cytocompatibility. The findings gained herein are useful for developing the high-oriented SCF reinforced polymer composites with superior biotribological and mechanical properties for artificial joints.


Asunto(s)
Benzofenonas , Fibra de Carbono , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Impresión Tridimensional , Fibra de Carbono/química , Polímeros/química , Polietilenglicoles/química , Cetonas/química , Ensayo de Materiales/métodos , Materiales Biocompatibles/química , Prótesis Articulares , Humanos
17.
Analyst ; 149(10): 3008-3016, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38606455

RESUMEN

Fast-scan cyclic voltammetry (FSCV) is a widely used technique for detecting neurotransmitters. However, electrode fouling can negatively impact its accuracy and sensitivity. Fouling refers to the accumulation of unwanted materials on the electrode surface, which can alter its electrochemical properties and reduce its sensitivity and selectivity. Fouling mechanisms can be broad and may include biofouling, the accumulation of biomolecules on the electrode surface, and chemical fouling, the deposition of unwanted chemical species. Despite individual studies discussing fouling effects on either the working electrode or the reference electrode, no comprehensive study has been conducted to compare the overall fouling effects on both electrodes in the context of FSCV. Here, we examined the effects of biofouling and chemical fouling on the carbon fiber micro-electrode (CFME) as the working electrode and the Ag/AgCl reference electrode with FSCV. Both fouling mechanisms significantly decreased the sensitivity and caused peak voltage shifts in the FSCV signal with the CFME, but not with the Ag/AgCl reference electrode. Interestingly, previous studies have reported peak voltage shifts in FSCV signals due to the fouling of Ag/AgCl electrodes after implantation in the brain. We noticed in a previous study that energy-dispersive spectroscopy (EDS) spectra showed increased sulfide ion concentration after implantation. We hypothesized that sulfide ions may be responsible for the peak voltage shift. To test this hypothesis, we added sulfide ions to the buffer solution, which decreased the open circuit potential of the Ag/AgCl electrode and caused a peak voltage shift in the FSCV voltammograms. Also, EDS analysis showed that sulfide ion concentration increased on the surface of the Ag/AgCl electrodes after 3 weeks of chronic implantation, necessitating consideration of sulfide ions as the fouling agent for the reference electrodes. Overall, our study provides important insights into the mechanisms of electrode fouling and its impact on FSCV measurements. These findings could inform the design of FSCV experiments, with the development of new strategies for improving the accuracy and reliability of FSCV measurements in vivo.


Asunto(s)
Incrustaciones Biológicas , Técnicas Electroquímicas , Neurotransmisores , Neurotransmisores/análisis , Incrustaciones Biológicas/prevención & control , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Animales , Compuestos de Plata/química , Fibra de Carbono/química , Microelectrodos , Sulfuros/química , Electrodos
18.
Int J Numer Method Biomed Eng ; 40(6): e3827, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38623951

RESUMEN

A prosthetic knee is designed to replace the functionality of an anatomical knee in transfemoral amputees. The purpose of a prosthetic knee is to restore mobility and compensate amputees for their impairment. In the present research numerical modelling and simulation of a carbon fabric reinforced polymer made polycentric prosthetic knee with four-bar mechanism was performed. Virtual prototyping with computer-aided design and computer-aided engineering software ensured geometric and structural stability of the knee design. The linkage mechanism, instantaneous centre's location and trajectory were investigated using multibody dynamics and analytical formulations. Computational simulations with a non-linear finite element model were employed with joints, contact formulations and an orthotropic material model to predict the displacement, stress formulated and life of the knee prosthesis under static and cyclic loading conditions. Finite element analysis assessed the strength and durability of knee in accordance to standards. Maximum Principal stress of 155 MPa and life expectancy of 3.1 × 106 cycles were determined for the composite knee through numerical simulations ensuring a safe design. Experimental testing was also conducted as per standards and the percentage error was estimated to be 2.52%, thereby establishing the validity of the finite element model deployed. This type of simulation-based approach can be implemented to efficiently and affordably design and prototype a prosthetic knee with desired functioning criteria.


Asunto(s)
Análisis de Elementos Finitos , Prótesis de la Rodilla , Polímeros , Diseño de Prótesis , Humanos , Polímeros/química , Simulación por Computador , Fibra de Carbono/química , Diseño Asistido por Computadora , Carbono/química , Estrés Mecánico , Ensayo de Materiales
19.
Environ Res ; 252(Pt 1): 118881, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38582430

RESUMEN

Nitrate reduction in bio-electrochemical systems (BESs) has attracted wide attention due to its low sludge yields and cost-efficiency advantages. However, the high resistance of traditional electrodes is considered to limit the denitrification performance of BESs. Herein, a new graphene/polypyrrole (rGO/PPy) modified electrode is fabricated via one-step electrodeposition and used as cathode in BES for improving nitrate removal from wastewater. The formation and morphological results support the successful formation of rGO/PPy nanohybrids and confirm the part covalent bonding of Py into GO honeycomb lattices to form a three-dimensional cross-linked spatial structure. The electrochemical tests indicate that the rGO/PPy electrode outperforms the unmodified electrode due to the 3.9-fold increase in electrochemical active surface area and 6.9-fold decrease in the charge transfer resistance (Rct). Batch denitrification activity tests demonstrate that the BES equipped with modified rGO/PPy biocathode could not only achieve the full denitrification efficiency of 100% with energy recovery (15.9 × 10-2 ± 0.14 A/m2), but also favor microbial attach and growth with improved biocompatible surface. This work provides a feasible electrochemical route to fabricate and design a high-performance bioelectrode to enhance denitrification in BESs.


Asunto(s)
Desnitrificación , Electrodos , Grafito , Polímeros , Pirroles , Grafito/química , Polímeros/química , Pirroles/química , Técnicas Electroquímicas/métodos , Fuentes de Energía Bioeléctrica , Nitratos/química , Carbono/química , Fibra de Carbono/química
20.
Acta Biomater ; 180: 128-139, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38636789

RESUMEN

Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri­implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri­implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri­implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri­implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.


Asunto(s)
Benzofenonas , Placas Óseas , Fibra de Carbono , Carbono , Inflamación , Cetonas , Polietilenglicoles , Polímeros , Titanio , Humanos , Cetonas/química , Titanio/química , Titanio/efectos adversos , Polietilenglicoles/química , Polímeros/química , Fibra de Carbono/química , Carbono/química , Masculino , Inflamación/patología , Femenino , Persona de Mediana Edad , Anciano , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA