Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
1.
Vet Surg ; 53(5): 904-917, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38741348

RESUMEN

OBJECTIVE: To report the outcomes of 15 dogs and two cats with metabone fractures treated with fluoroscopically guided normograde metabone pinning (FGNMP). STUDY DESIGN: Retrospective case series. ANIMALS: A total of 15 client owned dogs and two cats with 57 metabone fractures. METHODS: Description of FGNMP and reporting of the following data: signalment, pre- and postoperative radiographs, intramedullary pin diameter used, anesthesia, surgery and coaptation times, duration to normal weightbearing and bone union, postoperative care and complications. RESULTS: Median surgery time was 54 min (range: 26-99), median duration of coaptation was 14 days (range: 1-5 weeks), median time to normal weightbearing was 16 days (range: 2-45) and median time to bone union was 6 weeks (range: 4-12). All cases had at least 12 months of post-surgical follow-up with a median follow-up of 18 months (range: 12-70). No major complications occurred. Mild radiographic changes associated with subchondral bone sclerosis were noted on follow-up radiographs in 13/57 fractures. All cases returned to normal gait and full (15) or acceptable (2) function. CONCLUSION: In this study, FGNMP was an effective and safe technique for metabone fracture repair, requiring only short-term external coaptation in most patients. Time to bone union and return to normal function compared favorably to previously reported techniques. CLINICAL RELEVANCE: Fluoroscopically guided normograde metabone pinning provides an alternative technique for treatment of metabone fractures.


Asunto(s)
Clavos Ortopédicos , Fracturas Óseas , Animales , Perros/lesiones , Gatos , Estudios Retrospectivos , Masculino , Femenino , Clavos Ortopédicos/veterinaria , Fracturas Óseas/veterinaria , Fracturas Óseas/cirugía , Fluoroscopía/veterinaria , Resultado del Tratamiento , Enfermedades de los Perros/cirugía , Enfermedades de los Gatos/cirugía
2.
J Vet Intern Med ; 38(3): 1449-1457, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38561963

RESUMEN

BACKGROUND: Aerophagia (ingestion of air), is a functional aerodigestive disorder in people. Criteria for diagnosis of aerophagia in dogs are >1/3 of bolus volume containing air or ingested air resulting in gastric distention (>1/3 of end gastric volume). Aerophagia is highlighted during eating and drinking. Videofluoroscopic swallow studies (VFSS) document aerophagia in dogs, but the incidence, clinical signs (CS), and associated disorders are unknown. OBJECTIVES: Identify the incidence of aerophagia, compare CS between dogs with and without aerophagia, and identify associated and predisposing disorders using VFSS. ANIMALS: A total of 120 client-owned dogs. METHODS: Sequential VFSS and associated medical records from dogs presenting to veterinary teaching hospitals at Auburn University and the University of Missouri were retrospectively reviewed. Statistical comparisons were made using Mann-Whitney and chi-squared tests, odds ratios (OR), and multiple logistic regression (P < .05). RESULTS: The incidence (95% confidence interval [CI]) of aerophagia was 40% (31.7-48.9). Dogs with mixed CS (gastrointestinal [GI] and respiratory; P < .001, 58.3%) were more likely to have aerophagia than dogs with exclusively respiratory CS (25%). Aerophagia was significantly more common in brachycephalic dogs (P = .01; 45.8% vs 13.8%), dogs with nonbrachycephalic upper airway obstruction (P < .001; 33.3% vs 4.1%), pathologic penetration and aspiration (P-A) scores (P = .04; 41.6% vs 23.6%), and gagging (P < .001; 25% vs 11.7%). Mixed CS (P = .01), brachycephaly (P < .001), and upper airway obstruction (P < .001) were independent predictors of aerophagia. CONCLUSIONS AND CLINICAL IMPORTANCE: Aerophagia was common, particularly in dogs with mixed CS. Brachycephalic dogs and dogs with upper airway obstruction are predisposed. Aspiration risk was high, emphasizing overlapping upper aerodigestive pathways.


Asunto(s)
Enfermedades de los Perros , Animales , Perros , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/epidemiología , Femenino , Masculino , Estudios Retrospectivos , Fluoroscopía/veterinaria , Incidencia , Aerofagia/veterinaria , Grabación en Video , Deglución/fisiología
3.
Vet Radiol Ultrasound ; 65(3): 219-226, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38363122

RESUMEN

Bronchomalacia, the weakening of bronchial cartilage, is a common cause of cough in dogs. The gold standard for diagnosis of bronchomalacia is bronchoscopy; however, fluoroscopy is often used as a preliminary diagnostic test due to its noninvasiveness. The normal amount of bronchial collapse in healthy dogs using fluoroscopy has not been previously established, with some authors citing <25%. The aims of this prospective and retrospective analytical observational study were to determine the normal amount of airway collapse in healthy animals, the amount of airway collapse in dogs with chronic cough and presumed bronchomalacia, and cut-off values of airway collapse during expiration and cough to distinguish between the two groups. Thoracic fluoroscopy was performed in right and left lateral recumbency during inspiration, expiration, and cough to evaluate the percentage collapse of the trachea and lobar bronchi in 45 healthy and 76 chronically coughing dogs. The bronchi of chronically coughing dogs exhibited a significantly greater amount of collapse during both expiration and cough compared with healthy dogs. Chronically coughing dogs exhibited up to 31.7 ± 26.6% collapse in expiration and 87.5 ± 23.7% collapse during cough, whereas healthy dogs exhibited 14.9 ± 6.1% collapse in expiration and 35.0 ± 13.7% collapse during cough. Based on ROC curves, the authors suggest using cut-off values of 30% during expiration and 60% during cough to distinguish between healthy dogs and those with presumed bronchomalacia. Findings suggest that though healthy dogs can exhibit a greater degree of airway collapse than previously thought, fluoroscopy can be used to distinguish between healthy and presumed bronchomalacic dogs.


Asunto(s)
Tos , Enfermedades de los Perros , Animales , Perros , Tos/veterinaria , Fluoroscopía/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/diagnóstico , Masculino , Femenino , Estudios Prospectivos , Estudios Retrospectivos , Broncomalacia/veterinaria , Broncomalacia/diagnóstico por imagen , Bronquios/diagnóstico por imagen , Enfermedad Crónica/veterinaria , Valores de Referencia
4.
Vet Surg ; 53(4): 603-612, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38240128

RESUMEN

OBJECTIVE: To describe fluoroscopically-assisted closed reduction and percutaneous fixation of sacroiliac-luxation (SIL) in cats and report radiographic results and long-term functional outcomes. STUDY DESIGN: Retrospective clinical study. ANIMALS: Eleven cats. METHODS: Percutaneous fixation of 17 SILs in 11 cats was performed with 2.4 mm headless cannulated compression screws under fluoroscopic guidance. Luxation-reduction, screw placement and purchase within the sacral body, pelvic canal diameter ratio (PCDR) and hemipelvic canal width ratio (HCWR) were assessed on pre- and postoperative radiographs. Radiographic follow-up was performed to assess the same parameters when available. Long-term clinical outcome was evaluated with an owner questionnaire. Wilcoxon paired-test was performed for comparison. RESULTS: Mean age and bodyweight of the cats were 3.3 ± 2.6 years and 4.0 ± 0.82 kg, respectively. Nine cats presented with concurrent pelvic injuries. Median luxation-reduction was 94.1% (IQR = 13.9) and median screw-purchase within the sacral body was 73.3% (IQR = 17.0) immediately postoperatively. One screw exited the sacral body caudally. Upon 7-week radiographic follow-up, luxation-reduction (88.3%, IQR = 20.1) and screw-purchase (70.7%, IQR = 12.8) had decreased compared to immediately postoperatively (p = .008 and p = .013 respectively). Screw migration was not observed. PCDR and HCWR measured on postoperative radiographs indicated successful restoration of the pelvic canal width. Owners reported an excellent long-term functional outcome (mean postoperative time: 19 ± 5 months). CONCLUSION: Fluoroscopically-assisted closed reduction and fixation of feline SIL using 2.4 mm headless cannulated compression screws allowed good reduction and optimal screw purchase within the sacral body. An excellent functional outcome was reported. CLINICAL SIGNIFICANCE: Minimally invasive reduction and fixation with headless compression screws should be considered in cats with SIL.


Asunto(s)
Tornillos Óseos , Luxaciones Articulares , Articulación Sacroiliaca , Animales , Gatos , Tornillos Óseos/veterinaria , Estudios Retrospectivos , Masculino , Femenino , Fluoroscopía/veterinaria , Articulación Sacroiliaca/cirugía , Articulación Sacroiliaca/lesiones , Luxaciones Articulares/veterinaria , Luxaciones Articulares/cirugía , Resultado del Tratamiento , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación
5.
Vet Surg ; 53(1): 84-95, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37280738

RESUMEN

OBJECTIVE: To compare intra- and interobserver agreements in two-dimensional measurements of changes in nasopharyngeal dimensions during breathing in pugs and French bulldogs. STUDY DESIGN: Experimental randomized study. ANIMALS: A total of 20 French bulldogs and 16 pugs. METHODS: Four observers with different levels of experience measured the dorsoventral dimensions of the nasopharynx during inspiration and expiration on fluoroscopy videos. Measurements were performed at the maximal narrowing of the nasopharynx for the functional method and at the level of the tip of the epiglottis for the anatomically adjusted method. The intra- and interobserver agreements of the measurements, ratio of the dynamic nasopharyngeal change (ΔL), and grade of nasopharyngeal (NP) collapse (no, partial or complete) were evaluated. RESULTS: The functional method resulted in intraobserver correlation coefficients of 0.532 (p < .01) and 0.751 (p < .01) and interobserver correlation coefficients of 0.378 (p < .01) and 0.621 (p < .01) for NP collapse grade and ΔL, respectively. The anatomically adjusted method, 0.491 (p < .01) and 0.576 (p < .01) and 0.495 (p < .01) and 0.729 (p < .01) for NP collapse grade and ΔL, respectively, were being used. One observer (radiologist) achieved intraobserver correlation coefficients >0.9 for both methods. CONCLUSION: Fair interobserver agreement was found for NP collapse grade (functional method), moderate intra- and interobserver agreements were found for NP collapse grade and ΔL (both methods) while intraobserver agreement for ΔL was good (functional method). CLINICAL SIGNIFICANCE: Both methods seem repeatable and reproducible but only for experienced radiologists. The use of ΔL may offer higher repeatability and reproducibility than grade of NP collapse regardless of the method used.


Asunto(s)
Epiglotis , Nasofaringe , Perros , Animales , Reproducibilidad de los Resultados , Nasofaringe/diagnóstico por imagen , Fluoroscopía/veterinaria , Variaciones Dependientes del Observador
6.
J Am Vet Med Assoc ; 262(3): 1-6, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38056071

RESUMEN

OBJECTIVE: Perform a cadaveric experimental pilot study to measure and compare potential radiation exposure to an orthopedic surgeon from 2 different-generation mini C-arm models during a simulated orthopedic surgery. SAMPLE: 16 radiation dosimeters. METHODS: Mock surgery setups were constructed with a canine cadaver thoracic limb and 2 different-generation mini C-arm models. Four radiation dosimeters were placed near the mini C-arm to mimic common locations of radiation exposure during image acquisition. One mini C-arm was placed in auto technique mode, and 100 static images were acquired. The dosimeters were replaced, and a 5-minute-long dynamic image was acquired. The same protocols were repeated for the second mini C-arm. The dosimetry badges were then submitted for radiation exposure quantification. RESULTS: All but 1 dosimeter had radiation exposure levels below the detectable limits of the dosimeter. The dosimeter closest to the primary x-ray beam of 1 mini C-arm during dynamic image acquisition had a reading of 1 mrem. CLINICAL RELEVANCE: Intraoperative radiation exposure from the mini C-arm is low, specifically to areas not protected by lead and in close proximity to the primary x-ray beam. That being said, surgeons should always practice the principles of ALARA (ie, as low as reasonably achievable) to minimize radiation exposure in the workplace.


Asunto(s)
Exposición Profesional , Cirujanos Ortopédicos , Exposición a la Radiación , Animales , Perros , Humanos , Proyectos Piloto , Dosis de Radiación , Fluoroscopía/veterinaria , Exposición Profesional/análisis
7.
J Am Vet Med Assoc ; 262(1): 1-7, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37922706

RESUMEN

OBJECTIVE: Deep-seated pulmonary lesions can be difficult to sample safely. The objective of this study was to determine the relative safety and accuracy of fluoroscopy-guided fine-needle aspiration of deep-seated pulmonary lesions regardless of their size and depth. ANIMALS: Client-owned animals; 5 dogs and 5 cats. CLINICAL PRESENTATION: Pulmonary lesion locations were determined on dorsoventral and lateral views using fluoroscopy. The lateral thoracic wall was aseptically scrubbed, and an indelible marker was used to mark the point of entry of the needle for sampling. The path of a 22-gauge needle attached to a syringe was followed using fluoroscopic guidance. Mass volume (Vma) and distance from skin and pleura to lesion (DSK-L and DPL-L) were recorded. RESULTS: In dogs, mean Vma was 137.2 cm3 (range, 6.3 to 426.2 cm3). Mean DSK-L was 71 mm (range, 37 to 101 mm) and DPL-L was 33 mm (range, 16 to 71 mm). Exfoliative cytology results were consistent with carcinoma in 4 dogs and lymphoma in 1 dog. A minor postprocedural complication was noted in 1 dog. In cats, the mean Vma was 2.4 cm3 (range, 1.6 to 3.7 cm3). Mean DSK-L was 42 mm (range, 20 to 75 mm) and DPL-L was 21 mm (range, 12 to 32 mm). Cytology results were consistent with pulmonary carcinoma in 2 cats, inflammation in 2 cats, and necrotic debris in 1 cat. CLINICAL RELEVANCE: Fluoroscopy-guided fine-needle aspiration of pulmonary masses is a safe and accurate technique to obtain cytologic samples irrespective of the size and depth of the lesions.


Asunto(s)
Carcinoma , Enfermedades de los Gatos , Enfermedades de los Perros , Humanos , Gatos , Perros , Animales , Biopsia con Aguja Fina/veterinaria , Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Gatos/patología , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/patología , Carcinoma/veterinaria , Fluoroscopía/veterinaria
8.
Vet Surg ; 53(1): 155-166, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37770751

RESUMEN

OBJECTIVE: The aim of this study was to assess screw placement in simulated dorsomedial-plantarolateral central tarsal bone (CTB) fractures using two imaging guidance techniques - computed tomography (CT) with fluoroscopy compared to digital radiography alone (DR). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Equine cadaver hindlimbs (n = 10 pairs). METHODS: One tarsus per pair was randomly assigned to have a 4.5 mm cortical screw placed across the CTB using CT and fluoroscopy (CT/F group) or digital radiography alone (DR group). Postoperative CT was performed on all limbs. Variables related to marker placement, procedure time, and screw positioning were recorded and compared using a paired t-test for dependent means (p < .05). RESULTS: Time for marker placement was longer for the CT/F group (p = .001), with no difference in total procedure time (p = .12). CT/F was not superior to radiography alone (p > .05) for parameters related to screw positioning. Based on the 95% CI, there was greater range in relative screw length using radiography (76.5%-91.2%) versus CT/F (78.4%-84.0%). CONCLUSION: Internal fixation of CTB fractures can be successfully performed using either technique for imaging guidance. CT and fluoroscopy did not result in faster or more accurate screw placement compared to radiographs alone, except in determining screw length. CLINICAL SIGNIFICANCE: Mild adjustments in fluoroscopic or radiographic angle appeared to be a point of variability in the perception of screw placement. While CT is recommended for improved understanding of fracture configuration and surgical planning, radiographic guidance may be a suitable alternative for internal fixation of dorsomedial-plantarolateral fractures.


Asunto(s)
Fracturas Óseas , Enfermedades de los Caballos , Huesos Tarsianos , Caballos/cirugía , Animales , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/veterinaria , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fluoroscopía/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Tomografía Computarizada por Rayos X/métodos , Huesos Tarsianos/diagnóstico por imagen , Huesos Tarsianos/cirugía
9.
J Am Anim Hosp Assoc ; 59(4): 193-197, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37432786

RESUMEN

Two cats were presented with acute left-sided paresis after implantation of a microchip at the referring veterinary clinic. Neurological examinations were consistent with left-sided lesions between spinal cord segments C1 and C5. Orthogonal radiographs of the cervical spine showed a microchip dorsoventrally oriented, partially embedded in the cervical vertebral canal. Fluoroscopy was used to localize and retrieve the foreign body from the cervical spinal cord in each case. Improvement in clinical condition and return to ambulation was observed in both cats within 48 hr of surgical removal of the implant. No significant perioperative adverse events were noted during the surgical retrieval of the microchip. Two previously reported cases of intraspinal canal microchip placement had been treated surgically by hemilaminectomy. This approach carries a risk of complications, including hemorrhage from the venous sinus, iatrogenic damage to the spinal cord, and improper identification of the surgical site, requires advanced surgical training, and typically has an extended surgical time. The use of fluoroscopy to assist intraoperative localization of a spinal canal foreign body may lessen the requirement for more invasive surgical procedures.


Asunto(s)
Cuerpos Extraños , Médula Espinal , Animales , Fluoroscopía/veterinaria , Vértebras Cervicales/cirugía , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/cirugía , Cuerpos Extraños/veterinaria , Canal Medular
10.
Am J Vet Res ; 84(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37406998

RESUMEN

OBJECTIVE: To evaluate the ease and accuracy of using a 3-D printed (3-DP) drill guide to insert Kirschner wires through the ilium and into the sacral body in preparation for minimally invasive iliosacral screw placement in dog cadavers. ANIMALS: 10 dog cadavers weighing 20 to 30 kg (mean ± SD, 24.5 ± 5 kg). METHODS: Kirschner wires were placed using a limited approach to the lateral ilium. Fluoroscopy was used in freehand and 3-DP drill guide application groups to facilitate the placement of a 1.0-mm Kirschner wire that was over-drilled using a 2.5-mm cannulated drill bit. Kirschner wires were placed using a 3-DP drill guide on 1 hemipelvis and freehand wire placement was done on the contralateral hemipelvis. Postprocedural CTs were obtained, and 2-D and 3-D analyses were performed. The Student t-test and Wilcoxon rank sum test were used to compare groups. A Pearson correlation coefficient was performed to evaluate the in-group correlation. RESULTS: Likert scores that assessed the ease of the procedure were significantly greater (P = .04) and the incision length was significantly shorter (P = .016) in the 3-DP drill guide group compared with the freehand group. The time of the procedure, the number of attempts to obtain accurate Kirschner wire placement, and fluoroscopy images did not differ (P > .05) between application groups. Drill tracks were primarily confined to the sacral body, with minor projected screw thread cortical breeches occurred in 1 cadaver in the freehand group and 2 cadavers in the 3-DP drill guide group. CLINICAL RELEVANCE: The 3-DP drill guide simplified appropriate iliosacral Kirschner wire placement through a smaller incision compared with freehand drilling and would appear to be an efficient, practical instrument to facilitate accurate fluoroscopic-assisted screw placement when stabilizing sacroiliac luxations in dogs.


Asunto(s)
Hilos Ortopédicos , Enfermedades de los Perros , Perros , Animales , Hilos Ortopédicos/veterinaria , Tornillos Óseos/veterinaria , Sacro/diagnóstico por imagen , Sacro/cirugía , Fluoroscopía/veterinaria , Cadáver
11.
Vet Radiol Ultrasound ; 64(4): 713-723, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37133979

RESUMEN

In human medicine, magnetic resonance cholangiopancreatography (MRCP) is a valuable diagnostic tool for hepatobiliary and pancreatic diseases. In veterinary medicine, however, data evaluating the diagnostic value of MRCP are limited. The primary objectives of this prospective, observational, analytical investigation were to assess whether MRCP reliably visualizes the biliary tract and pancreatic ducts in cats without and with related disorders, and whether MRCP images and measurements of the ducts agree with those of fluoroscopic retrograde cholangiopancreatography (FRCP), corrosion casting and histopathology. A secondary objective was to provide MRCP reference diameters for bile ducts, GB, and pancreatic ducts. Donated bodies of 12 euthanized adult cats underwent MRCP, FRCP, and autopsy with corrosion casting of the biliary tract and pancreatic ducts using vinyl polysiloxane. Diameters of the biliary ducts, gallbladder (GB), and pancreatic ducts were measured using MRCP, FRCP, corrosion casts and histopathologic slides. There was an agreement between MRCP and FRCP in measuring diameters of the GB body, GB neck, cystic duct, and common bile duct (CBD) at papilla. Strong positive correlations existed between MRCP and corrosion casting for measuring GB body and neck, cystic duct, and CBD at the extrahepatic ducts' junction. In contrast to the reference methods, post-mortem MRCP did not visualize right and left extrahepatic ducts, and pancreatic ducts in most cats. Based on this study, MRCP with 1.5 Tesla can be regarded as a contributory method to improve the assessment of feline biliary tract and pancreatic ducts when their diameter is >1 mm.


Asunto(s)
Imagen por Resonancia Magnética , Conductos Pancreáticos , Animales , Gatos , Autopsia/veterinaria , Colangiopancreatografia Retrógrada Endoscópica/veterinaria , Molde por Corrosión/veterinaria , Fluoroscopía/veterinaria , Imagen por Resonancia Magnética/veterinaria , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos
12.
J Vet Cardiol ; 47: 30-40, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37150018

RESUMEN

INTRODUCTION: Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units. ANIMALS: One hundred and fifty-four client-owned dogs. MATERIALS AND METHODS: Patient dose during procedures using a portable C-arm were retrospectively analyzed and compared to those performed in a contemporary interventional suite. Fluoroscopy equipment, procedure type, operator, patient weight, fluoroscopy time, dose area product, and air kerma were recorded and statistically modeled using univariable and multivariable linear regression to evaluate the effect of each factor. RESULTS: Patient dose population (154 dogs), comprised 61 patent ductus arteriosus occlusions, 60 balloon pulmonary valvuloplasties, and 33 pacemaker implantations. Patient dose was significantly lower in the group utilizing a newer generation fluoroscopy unit vs. the group utilizing an older portable C-arm, positively correlated with patient weight, and highest during balloon pulmonary valvuloplasties compared to patent ductus arteriosus occlusions or pacemaker implantations (all P<0.010). DISCUSSION: Newer fluoroscopy systems can be equipped with technologies that improve image quality while reducing patient dose and radiation exposure to interventional personnel. CONCLUSIONS: We documented a significant reduction in patient radiation dose using a newer fluoroscopy system as compared to an older portable C-arm for interventional cardiology procedures in animals. Improved knowledge of patient radiation dose factors may promote better radiation safety protocols in veterinary interventional cardiology.


Asunto(s)
Cateterismo Cardíaco , Enfermedades de los Perros , Conducto Arterioso Permeable , Animales , Perros , Conducto Arterioso Permeable/veterinaria , Estudios Retrospectivos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/veterinaria , Dosis de Radiación , Fluoroscopía/efectos adversos , Fluoroscopía/veterinaria , Enfermedades de los Perros/etiología
13.
Vet Surg ; 52(4): 538-544, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36929604

RESUMEN

OBJECTIVES: (1) To evaluate the accuracy of an aiming device on placement of humeral transcondylar screws compared to fluoroscopic methods. (2) To compare experience level on outcome. STUDY DESIGN: Randomized, match pair, prospective ex-vivo study. SAMPLE POPULATION: A total of 68 dogs. METHODS: Canine cadaveric forelimbs were randomly assigned to either aiming device or fluoroscopic-guided groups, and to diplomate or resident. Digital radiography was used to evaluate screw trajectory deviation and eccentricity on the humeral condyle. Procedure time, outcome based on experience, and complications were recorded. RESULTS: The aiming device screw trajectory angle was decreased in the right limb (1.9 ± 1.1°) compared with the left (3.6 ± 1.1°, p = .0178), and compared to fluoroscopy (3.4 ± 1.1° p = .0128). There was no difference between leg laterality with fluoroscopy (p = .9979). Trajectory angle was increased with resident versus diplomate (3.4 ± 1.1° and 2.5 ± 1.1° respectively, p = .0366). Eccentricity deviation was decreased using fluoroscopy versus aiming device (3.1 ± 0.36 mm, 4.2 ± 0.36 mm, respectively, p = .0017). The risk of joint involvement was 8 times greater in aiming device groups, though not significant (p = .0575). Significant complications included increased drill attempts in fluoroscopic groups (p = .0237). CONCLUSION: The aiming device provided accurate placement of transcondylar screws, in terms of both position on the condyle and trajectory angle. Results were similar to fluoroscopic-guided method. CLINICAL SIGNIFICANCE: An aiming device is an acceptable means of placing humeral transcondylar screws. The use of the aiming device had an eight times increased risk of joint involvement compared to fluoroscopy.


Asunto(s)
Tornillos Óseos , Fusión Vertebral , Perros , Animales , Estudios Prospectivos , Tornillos Óseos/veterinaria , Fluoroscopía/veterinaria , Fusión Vertebral/métodos , Fusión Vertebral/veterinaria , Húmero/cirugía
14.
J Vet Intern Med ; 37(3): 1166-1178, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36951400

RESUMEN

BACKGROUND: Aerodigestive diseases (AeroD) pathologically link respiratory and alimentary tracts. Dogs with respiratory signs lacking dysphagia, vomiting, or regurgitation typically do not undergo diagnostic testing that identifies comorbid alimentary disease. A videofluoroscopic swallow study (VFSS) identifies defects in swallowing, reflux, and aspiration. OBJECTIVES/HYPOTHESIS: We hypothesized that dogs with respiratory and no alimentary disease (RESP) would have significantly more abnormal VFSS metrics versus controls (CON). We hypothesized RESP dogs with pulmonary parenchymal disease would have more reflux and higher penetration-aspiration score (PAS) than those with airway disease. ANIMALS: Client-owned dogs: RESP (n = 45) and CON (n = 15) groups. METHODS: Prospectively, all dogs underwent VFSS. The RESP dogs had advanced respiratory diagnostic testing. Eight subjective and 3 objective VFSS metrics (pharyngeal constriction ratio [PCR], PAS, and esophageal transit time [ETT]) were assessed. Fisher's exact test compared differences between groups (presence or absence of VFSS abnormalities). The Mann-Whitney rank sum test was used to compare PCR and PAS. RESULTS: Subjective VFSS abnormalities were present in 34/45 (75%) RESP and 2/15 (13%) CON dogs, with RESP dogs significantly more likely to have VFSS abnormalities (P = .01). No difference in PCR was found between groups. Pathologic PAS was more common in RESP than CON dogs (P = .03). The RESP dogs with airway disease had higher PAS than CON dogs (P = .01) but not RESP dogs with parenchymal disease (P = .25). CONCLUSIONS: Most (75%) RESP dogs had VFSS abnormalities, emphasizing that AeroD are common. The VFSS has value in diagnostic evaluation of respiratory disease.


Asunto(s)
Trastornos de Deglución , Enfermedades de los Perros , Reflujo Gastroesofágico , Enfermedades Respiratorias , Perros , Animales , Fluoroscopía/veterinaria , Trastornos de Deglución/diagnóstico por imagen , Trastornos de Deglución/veterinaria , Deglución , Enfermedades Respiratorias/diagnóstico por imagen , Enfermedades Respiratorias/veterinaria , Reflujo Gastroesofágico/veterinaria , Enfermedades de los Perros/diagnóstico por imagen
15.
Vet Comp Orthop Traumatol ; 36(3): 163-168, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36812935

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate a fluoroscopic method of angle of lateral opening (ALO) categorization based on identification of the visible portion of a pre-existing, circular recess within the metal shell of the BioMedtrix BFX acetabular component, which projects as an ellipse at clinically relevant ALO values. Our hypothesis was that there will be an association between the actual ALO and the categorization of ALO based on identification of the visible portion of the elliptical recess on a lateral fluoroscopic image at clinically relevant values. STUDY DESIGN: A custom plexiglass jig was fitted with a two-axis inclinometer and a 24 mm BFX acetabular component attached to its tabletop. Fluoroscopic reference images were obtained with the cup positioned at an ALO of 35, 45 and 55 degrees with a fixed 10 degrees of retroversion. Thirty study fluoroscopic images (10 images at each ALO) were obtained based on randomization at an ALO of 35, 45 and 55 degrees (±0.5 degrees) with 10 degrees of retroversion. The order of the study images was randomized, and a single, blinded observer categorized the 30 study images as representing an ALO of 35, 45 or 55 degrees by comparison to the reference images. RESULTS: Analysis showed perfect (30/30) agreement with a weighted kappa coefficient of 1 (95% confidence interval: -0.717 to 1). CLINICAL RELEVANCE: The results demonstrate that accurate categorization of ALO can be achieved using this fluoroscopic method. This method may prove to be a simple but effective method of estimating intraoperative ALO.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Animales , Artroplastia de Reemplazo de Cadera/veterinaria , Artroplastia de Reemplazo de Cadera/métodos , Reproducibilidad de los Resultados , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Fluoroscopía/veterinaria , Fluoroscopía/métodos
16.
Vet Surg ; 52(6): 846-852, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35916574

RESUMEN

OBJECTIVES: To report the short-term clinical outcome and complications in dogs that underwent surgical repair of femoral capital physeal or neck fractures via fluoroscopic-guided percutaneous pinning (FGPP). STUDY DESIGN: Retrospective case series. ANIMALS: Client owned dogs (n = 11) with femoral capital physeal or neck fractures (n = 13). METHODS: Records (July 2018-July 2021) of dogs that underwent surgery for femoral capital physeal or neck fracture repair with FGPP from two hospitals were reviewed. Data collected included signalment, age, weight, preoperative lameness severity, fracture factors (etiology, Salter-Harris classification, time from injury to surgery, radiographic displacement), surgical factors (surgery time, number/size of implants, reduction quality) and outcome (follow-up examination findings, radiographic findings, complications). RESULTS: Most fractures (11/13) occurred secondary to trauma. The median time from injury to surgery was 5.5 days. There was mild radiographic displacement preoperatively in 10/13 fractures. Satisfactory fracture healing and limb function was achieved in 10/13 femurs. Complications occurred in 5/11 cases and included intra-articular implants, implant failure/nonunion, implant migration (2), and malunion. Of these five complications, two resolved with implant removal, and a salvage procedure was recommended in the remaining cases. Of the three cases requiring salvage procedures, two originally presented with radiographic evidence of fracture chronicity. CONCLUSIONS: FGPP can be used to successfully treat femoral head and neck fractures with appropriate case selection and precise surgical technique.


Asunto(s)
Enfermedades de los Perros , Fracturas del Fémur , Fracturas Óseas , Fracturas de la Columna Vertebral , Perros , Animales , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas Óseas/veterinaria , Fluoroscopía/veterinaria , Cabeza Femoral , Fracturas de la Columna Vertebral/veterinaria , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fracturas del Fémur/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía
17.
J Vet Cardiol ; 44: 23-37, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36272365

RESUMEN

Three-dimensional electroanatomical mapping (3D EAM) has expanded radiofrequency catheter ablation applications in humans to almost all complex arrhythmias and has drastically reduced fluoroscopy use, yet its potential in dogs is poorly investigated. The objectives of the current study were to assess the feasibility and safety of 3D EAM of all four heart chambers, 3D EAM-guided biopsies and transseptal puncture in dogs. Eight healthy purpose-bred Beagle dogs. Electroanatomical mapping was performed under general anaesthesia during sinus rhythm using a 22-electrode mapping catheter. Left heart catheterisation was achieved by either retrograde transaortic access (n = 4) or transseptal puncture (n = 4). Successful 3D EAM of the right atrium and ventricle was achieved in all dogs at a median time of 33 (13-40) min and 17 (3-52) min, respectively. Left atrial and ventricular 3D EAM was successful in six and seven dogs, at a median time of 17 (4-27) min and 8 min (4-19 min), respectively. Complications requiring intervention occurred in one dog only and were a transient third degree atrioventricular block and pericardial effusion following transseptal puncture, which was treated by pericardiocentesis. All dogs recovered uneventfully. Fluoroscopy time was limited to a median of 7 min (0-45 min) and almost exclusively associated with transseptal puncture. Three-dimensional EAM of all cardiac chambers, including mapping-guided biopsy and transseptal puncture is feasible in small dogs. Complications are similar to those reported in human patients. This suggests a potential added value of 3D EAM to conventional electrophysiology in dogs with arrhythmias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Enfermedades de los Perros , Perros , Humanos , Animales , Estudios de Factibilidad , Ablación por Catéter/veterinaria , Punciones/veterinaria , Punciones/métodos , Fluoroscopía/veterinaria , Arritmias Cardíacas/cirugía , Arritmias Cardíacas/veterinaria , Arritmias Cardíacas/etiología , Biopsia/veterinaria , Resultado del Tratamiento , Fibrilación Atrial/etiología , Fibrilación Atrial/veterinaria , Enfermedades de los Perros/cirugía
18.
J Vet Intern Med ; 36(6): 2149-2159, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36259261

RESUMEN

BACKGROUND: Videofluoroscopic swallow studies (VFSS) utilizing penetration-aspiration (P-A) scoring assesses airway protection in people. On VFSS, penetration (ingesta or secretions immediately cranial to the vocal folds) and aspiration (material caudal to the vocal folds) are associated with increased risk of lung injury in people. Penetration-aspiration (P-A) scoring has been validated in animal models, but the incidence of P-A, clinical signs (CS), and dysphagic disorders associated with P-A in dogs are unknown. OBJECTIVES: Using VFSS, identify the incidence of P-A, compare CS between dogs with and without P-A, and identify predisposing dysphagic abnormalities for P-A. ANIMALS: One hundred client-owned dogs. METHODS: Sequential VFSS and associated medical records from dogs presenting to the veterinary teaching hospitals at Auburn University (n = 53) and the University of Missouri (n = 47) were retrospectively reviewed. Statistical comparisons were made using Mann-Whitney tests, one-way analysis of variance (ANOVA) on ranks, multiple linear regression, and Spearman rank order correlation (P < .05). RESULTS: On VFSS, the incidence of pathologic P-A was 39%. No significant differences in CS were found between dogs with or without P-A (P > .05), with 14/39 dogs with P-A presenting without respiratory CS. Pharyngeal (P < .001) and esophageal (P = .009), but not oral-preparatory (P = .2) dysphagia was more common with P-A. Pharyngeal weakness (P < .001) and esophago-oropharyngeal reflux (EOR; P = .05) were independent predictors of P-A and were moderately and weakly positively correlated with P-A score respectively (P < .001, r = 0.489; P = .04, r = 0.201). CONCLUSIONS: Penetration-aspiration occurs in dogs in the absence of respiratory CS (i.e., occult P-A). Dogs with pharyngeal weakness and EOR should be considered at risk for P-A.


Asunto(s)
Trastornos de Deglución , Enfermedades de los Perros , Perros , Animales , Incidencia , Fluoroscopía/veterinaria , Estudios Retrospectivos , Grabación en Video , Trastornos de Deglución/veterinaria , Enfermedades de los Perros/diagnóstico por imagen
19.
J Am Vet Med Assoc ; 261(1): 80-86, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-36166502

RESUMEN

OBJECTIVE: To describe the current standard of care among specialists for the routine diagnostic evaluation and medical management of stable tracheal collapse in dogs, identifying gaps between practice and scientific evidence to facilitate the development of future prospective studies. A secondary objective was to describe the perceived incidence of selected comorbid disorders in dogs with tracheal collapse and the diagnostic tests performed to evaluate for those disorders. SAMPLE: 180 veterinary specialists in 22 countries. PROCEDURES: An electronic survey was sent to 4 specialty listservs to target diplomates. Respondents completed multiple-choice and free-response questions related to the diagnostic evaluation and treatment of a theoretical stable dog with suspected tracheal collapse. RESULTS: Most respondents routinely utilized radiography, tracheobronchoscopy, and fluoroscopy to diagnose tracheal collapse and performed airway sampling, sedated airway examination, and echocardiograms to rule out comorbidities. The most frequently perceived comorbid disorders included chronic bronchitis, bronchomalacia, and myxomatous mitral valve disease. Respondents most often prescribed opioid antitussives, glucocorticoids, anxiolytics, and antibiotics as treatments. Less frequently, they utilized bronchodilators and nonopioid medications for cough. CLINICAL RELEVANCE: Despite a lack of published guidelines, specialists have similar approaches in their diagnostic and therapeutic approach to a stable dog with suspected tracheal collapse and believe evaluating for comorbid disorders is important. A description of a typical diagnostic approach and knowledge of realistic treatment goals will assist the general practitioner managing dogs with stable tracheal collapse. Additionally, gaps between current practices established via this survey and data supporting those practices exist, specifically concerning the use of antibiotics and nonopioid medications for cough, representing areas for further study.


Asunto(s)
Enfermedades de los Perros , Enfermedades de la Tráquea , Animales , Perros , Tos/veterinaria , Estudios Prospectivos , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/tratamiento farmacológico , Enfermedades de los Perros/epidemiología , Radiografía , Fluoroscopía/veterinaria , Enfermedades de la Tráquea/complicaciones , Enfermedades de la Tráquea/diagnóstico , Enfermedades de la Tráquea/veterinaria
20.
J Avian Med Surg ; 36(2): 178-186, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35972870

RESUMEN

Fluoroscopic angiography evaluates the heart and vascular tree in real time and can be recorded for further diagnostic analysis and measurements. Although reports have been published of the use of fluoroscopic angiography in birds, this technique has not been evaluated in any avian species. The purpose of this study was to evaluate a fluoroscopic angiography protocol in 12 adult Hispaniolan Amazon parrots (Amazona ventralis). Under general anesthesia, the birds were positioned in right lateral (LAT) recumbency on a fluoroscopy table. A bolus of nonionic iodinated contrast agent was injected through a catheter inserted into the basilic or medial metatarsal vein during video acquisition. The same bolus was repeated to obtain the ventrodorsal (VD) view with the bird placed in dorsal recumbency. Eleven studies were performed. A total of 19 (10 VD, 9 LAT) continuous, real-time, fluoroscopic angiograms were successfully captured. The brachiocephalic trunk, aorta, pulmonary arteries, pulmonary veins, and caudal vena cava were visualized, and selected intraluminal measurements collected. The intraobserver and interobserver variability for 3 observers was calculated. Intraobserver agreement was found to be near perfect (intraclass correlation coefficient ≥0.95), whereas interobserver agreement was moderate to substantial (intraclass correlation coefficient ≥0.52). Coefficients of variation were excellent (VD 0.99, LAT 0.99) for intraobserver assessments and moderate (VD 0.72, LAT 0.52) for interobserver assessments. For the interobserver assessments, the VD projection measurements performed better than the LAT measurements. These results suggest that although there was some variation between different observers, relatively consistent vascular measurements could be obtained. The described fluoroscopic angiography protocol is a repeatable and reliable technique that could be useful for the diagnosis and monitoring of cardiovascular diseases in birds.


Asunto(s)
Amazona , Angiografía , Animales , Fluoroscopía/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA