Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.355
Filtrar
1.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747532

RESUMEN

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Mal Unidas , Osteotomía , Fracturas del Radio , Humanos , Femenino , Osteotomía/métodos , Osteotomía/instrumentación , Persona de Mediana Edad , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Anciano , Fracturas Mal Unidas/cirugía , Fracturas Mal Unidas/diagnóstico por imagen , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Impresión Tridimensional , Cirugía Asistida por Computador , Imagenología Tridimensional , Tornillos Óseos , Tomografía Computarizada por Rayos X
2.
Trials ; 25(1): 303, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711069

RESUMEN

BACKGROUND: With roughly 45,000 adult patients each year, distal radius fractures are one of the most common fractures in the emergency department. Approximately 60% of all these fractures are displaced and require surgery. The current guidelines advise to perform closed reduction of these fractures awaiting surgery, as it may lead to post-reduction pain relief and release tension of the surrounding neurovascular structures. Recent studies have shown that successful reduction does not warrant conservative treatment, while patients find it painful or even traumatizing. The aim of this study is to determine whether closed reduction can be safely abandoned in these patients. METHODS: In this multicenter randomized clinical trial, we will randomize between closed reduction followed by plaster casting and only plaster casting. Patients aged 18 to 75 years, presenting at the emergency department with a displaced distal radial fracture and requiring surgery according to the attending surgeon, are eligible for inclusion. Primary outcome is pain assessed with daily VAS scores from the visit to the emergency department until surgery. Secondary outcomes are function assessed by PRWHE, length of stay at the emergency department, length of surgery, return to work, patient satisfaction, and complications. A total of 134 patients will be included in this study with follow-up of 1 year. DISCUSSION: If our study shows that patients who did not receive closed reduction experience no significant drawbacks, we might be able to reorganize the initial care for distal radial fractures in the emergency department. If surgery is warranted, the patient can be sent home with a plaster cast to await the call for admission, decreasing the time spend in the emergency room drastically. TRIAL REGISTRATION: This trial was registered on January 27, 2023.


Asunto(s)
Moldes Quirúrgicos , Reducción Cerrada , Servicio de Urgencia en Hospital , Fracturas del Radio , Humanos , Fracturas del Radio/terapia , Fracturas del Radio/cirugía , Persona de Mediana Edad , Reducción Cerrada/métodos , Adulto , Anciano , Resultado del Tratamiento , Adolescente , Femenino , Ensayos Clínicos Controlados Aleatorios como Asunto , Adulto Joven , Masculino , Estudios Multicéntricos como Asunto , Factores de Tiempo , Satisfacción del Paciente , Dimensión del Dolor , Recuperación de la Función , Fracturas de la Muñeca
3.
BMC Musculoskelet Disord ; 25(1): 261, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570756

RESUMEN

BACKGROUND: Non-operative management is typically indicated for extra-articular distal radius fractures. Conservative treatments such as Sugar tong splints (STs) and Muenster splints (MUs) are commonly used. However, there is limited research and outcome data comparing the two splint types. Therefore, this study aimed to investigate and compare the radiographic and clinical outcomes of treatment using STs and MUs. METHODS: In this retrospective comparative study, we aimed to evaluate and compare the radiographic and clinical outcomes of STs and MUs for the treatment of distal radius fractures. The study included 64 patients who underwent closed reduction (CR) in the emergency room and were treated with either STs or MUs splints (STs group: n = 38, MUs group: n = 26). Initial X-rays, post-CR X-rays, and last outpatient follow-up X-rays were evaluated. Radial height (RH), ulnar variance (UV), radial inclination (RI), and volar tilt (VT) were measured by a blinded investigator. The Quick DASH form was applied to measure patients' satisfaction after treatments. RESULTS: There were no significant differences in baseline characteristics, initial radiographic measurements, or radiographic measurements immediately after CR between the two groups. However, the overall radiological values deteriorated to some degree in both groups compared to the post-CR images. Furthermore, using a paired test, the STs group showed significant differences in RH and RI, and the MUs group showed significant differences in RH and UV between the last follow-up and post-CR images. CONCLUSIONS: The study concluded that there was no difference in clinical outcomes between the two splint types. However, both STs and MUs groups showed reduced radiographic parameters, and the MUs group showed a significant reduction of RH and UV in the treatment of distal radius fractures. LEVEL OF EVIDENCE: Level IV; Retrospective Comparison; Treatment Study.


Asunto(s)
Fracturas del Radio , Fracturas de la Muñeca , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Férulas (Fijadores) , Azúcares , Fracturas del Radio/terapia , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Placas Óseas , Fijación Interna de Fracturas/métodos
4.
Ortop Traumatol Rehabil ; 26(1): 347-355, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38646904

RESUMEN

BACKGROUND: Radial neck fractures account for 5-17% of elbow fractures and about 1% of all fractures in children. The subject of the presented research is assesment of clinical and radiological outcomes of the Metaizeau technique for treatment of isolated radial neck fractures in children. MATERIAL AND METHODS: Retrospective analysis of clinical and radiological data of patients treated with the Metaizeau technique in our Department between 2015 and 2020. Twenty children with isolated radial neck fracture met the inclusion criteria. RESULTS: Excellent outcomes of operative treatment were achieved in 95% of children. None of the complications described in the literature (e.g. avascular necrosis of radial head (AVN), malunion, nonunion) were observed in our case series. CONLCUSIONS: 1. The Metaizeau technique for reduction and stabilisation of the radial neck fracture using a TEN is a safe and effective method in the paediatric population and produces good clinical and radiological results. 2.Furthermore, the minimal demands it places on surgical equipment make it possible for this technique to be recommended to orthopaedic surgeons managing paediatric trauma patients.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Radio , Humanos , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Masculino , Femenino , Niño , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Estudios de Casos y Controles , Adolescente , Preescolar , Radiografía/métodos , Fracturas Radiales de Cabeza y Cuello
5.
Arch Orthop Trauma Surg ; 144(5): 2007-2017, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38568386

RESUMEN

BACKGROUND: In acute treatment of radial head fractures, a radial head prosthesis can be considered if open reduction and internal fixation are not technically feasible. METHODS: We reviewed the data of 27 consecutive bipolar Judet radial head prostheses implanted in patients with unreconstructable radial head fractures and no other concomitant fractures (coronoid or olecranon factures). The lesions of the lateral collateral ligament were rated according to the McKee classification. Twenty-three patients with more than ten-year follow-up participated in this retrospective study All patients underwent assessments for pain, range of motion and stability using the Mayo Elbow Performance Score, the QuickDash questionnaire and a Visual Analogue Scale for pain. Radiography assessment was performed to determine the correct setting of the implant, presence of periprosthetic loosening, prosthetic disassembly, heterotopic ossification, capitellum and ulnohumeral degenerative changes. RESULTS: Mean follow-up was 149 months (± 12.2). Mean range of motion in flexion-extension was 111° (± 10.55), mean extension was 18° (± 14.32) and mean flexion was 130° (± 11.4). Mean arc of motion in supination-pronation was 150° (± 12.26). The mean Mayo Elbow Performance Score was 88, the mean QuickDash score was 7.3; 86% of the patients were satisfied. Seven patients (26%) required secondary surgery. The most frequent complication was heterotopic ossification, which had negative consequences on the functional result. CONCLUSIONS: Bipolar radial head prostheses are an option for acute treatment of isolated unreconstructable radial head fractures. During follow-up, three patients required implant revision and removal; the capitellum surface presented severe degenerative changes and the prosthesis was not replaced. Another complication was the risk of implant dislocation, in relation to implant design, incorrect positioning of the radial head stem or else to inadequate reconstruction of the lateral collateral ligament. Further work is needed to establish the long-term follow-up results of Judet implants in complex elbow fractures.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Fracturas del Radio/cirugía , Fracturas del Radio/fisiopatología , Adulto , Anciano , Articulación del Codo/cirugía , Articulación del Codo/fisiopatología , Articulación del Codo/diagnóstico por imagen , Resultado del Tratamiento , Artroplastia de Reemplazo de Codo/métodos , Rango del Movimiento Articular , Diseño de Prótesis , Estudios de Seguimiento , Prótesis de Codo
6.
Ann Anat ; 254: 152267, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38649115

RESUMEN

BACKGROUND: Reasonable postoperative humeroradial and humeroulnar joint spaces maybe an important indicator in biomechanical stability of smart internal fixation surgery for coronoid process basal fractures (CPBF). The aim of this study is to compare elbow articular stresses and elbow-forearm stability under smart internal fixations for the CPBF between normal elbow joint spaces and radius-shortening, and to determine the occult factor of radius-ulna load sharing. METHODS: CT images of 70 volunteers with intact elbow joints were retrospectively collected for accurate three-dimensional reconstruction to measure the longitudinal and transverse joint spaces. Two groups of ten finite element (FE) models were established prospectively between normal joint space and radius-shortening with 2.0 mm, including intact elbow joint and forearm, elbow-forearm with CPBF trauma, anterior or posterior double screws-cancellous bone fixation, mini-plate-cancellous bone fixation. Three sets of physiological loads (compression, valgus, varus) were used for FE intelligent calculation, FE model verification, and biomechanical and motion analysis. RESULTS: The stress distribution between coronoid process and radial head, compression displacements and valgus angles of elbow-forearm in the three smart fixation models of the normal joint spaces were close to those of corresponding intact elbow model, but were significantly different from those of preoperative CPBF models and fixed radius-shortening models. The maximum stresses of three smart fixation instrument models of normal joint spaces were significantly smaller than those of the corresponding fixed radius-shortening models. CONCLUSIONS: On the basis of the existing trauma of the elbow-forearm system in clinical practice, which is a dominant factor affecting radius-ulna load sharing, the elbow joint longitudinal space has been found to be the occult factor affecting radius-ulna load sharing. The stability and load sharing of radius and ulna after three kinds of smart fixations of the CPBF is not only related to the anatomical and biomechanical stability principles of smart internal fixations, but also closely related to postoperative elbow joint longitudinal space.


Asunto(s)
Articulación del Codo , Fijación Interna de Fracturas , Radio (Anatomía) , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Masculino , Femenino , Articulación del Codo/cirugía , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/anatomía & histología , Radio (Anatomía)/cirugía , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/anatomía & histología , Adulto , Persona de Mediana Edad , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Cúbito/cirugía , Soporte de Peso , Estudios Retrospectivos , Adulto Joven , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano
7.
Acta Orthop Belg ; 90(1): 110-114, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669659

RESUMEN

The aim of the study was to evaluate the results of Dorsal Wrist Plating in intra-articular distal radius fractures with a dorsal displacement. In this prospective study, a single surgeon treated 20 patients with a (partially) intra-articular distal radius fracture with a dorsal rim avulsion or a dorsal Barton's type fragment. They all underwent an open reduction and internal fixation by Dorsal Wrist Plating. A total of 17 patients had a follow-up period of at least 12 months (mean follow- up of 17 months) and these patients were included in the study. Both functional and radiological outcome parameters were measured. The total range of motion was 92 % of the contralateral side. The mean grip strength and key pinch were 24.6 kg and 6.9kg respectively compared to 29.5 kg and 7.4 kg on the non-operated side. The average Mayo Wrist Score was 89.7 (range 80-100) and the mean Disability of the Arm, Shoulder and Hand score was 4.5 (range 0-9.2). An articular step-off was only noted in 2 patients (1 and 2 mm respectively). Radial inclination was restored in all patients. Palmar tilt was anatomically restored in five patients. In all other patients, the palmar tilt was acceptably restored. There was no significant radial shortening in any of the patients. No infections, no tendon ruptures, no Complex Regional Pain Syndrome, or union problems were observed. Dorsal wrist plating seems to be a safe and reliable procedure in the treatment of intra-articular distal radius fractures with dorsal displacement.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Intraarticulares , Fracturas del Radio , Rango del Movimiento Articular , Humanos , Fracturas del Radio/cirugía , Masculino , Femenino , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Persona de Mediana Edad , Adulto , Anciano , Estudios Prospectivos , Fracturas Intraarticulares/cirugía , Fuerza de la Mano , Articulación de la Muñeca/cirugía , Articulación de la Muñeca/fisiopatología , Resultado del Tratamiento , Adulto Joven , Fracturas de la Muñeca
9.
J Orthop Surg Res ; 19(1): 223, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575946

RESUMEN

BACKGROUND: Concomitant injuries to the radiocarpal ligaments may occur during episodes of distal radius fractures, which may not cause acute subluxation or dislocation but can lead to radiocarpal instability and progress over time. This study aimed to analyze the occurrence of ulnar carpal translation (UCT) after open reduction and internal fixation of distal radius fractures and evaluate the associated factors of UCT. METHODS: The retrospective study has been done now and includes patients treated between 2010 and 2020 who had undergone reduction and locking plate fixation of distal radius fractures. We assessed radiographs taken immediately after the operation and at 3 months post-operation, enrolling patients with UCT for evaluation. In addition to demographic data, we evaluated radiographic parameters, including fracture pattern, fragment involvement, and ulnar variance. We also assessed the palmar tilt-lunate (PTL) angle to determine associated rotatory palmar subluxation of the lunate (RPSL). RESULTS: Among the 1,086 wrists, 53 (4.9%) had UCT within 3 months post-operation. The majority of wrists with UCT exhibited normal to minus ulnar variance (49 wrists; mean: -1.1 mm), and 24 patients (45.3%) had concomitant RPSL. Fracture classification was as follows: 19 type A3 (35.8%), 5 type C1 (9.4%), 11 type C2 (20.8%), and 18 type C3 (34.0%). Radial styloid was involved in 20 wrists (37.7%), palmar rim in 18 wrists (34.0%), dorsal rim in 25 wrists (47.2%), and die-punch fractures in 3 wrists (5.7%). Concomitant ulnar styloid fractures were present in 29 wrists (54.7%). CONCLUSION: This study highlights the potential for UCT to occur following reduction and fixation of distal radius fractures, particularly in cases with a more severe fracture pattern and combined with ulnar minus variance. The high incidence of concomitant RPSL provides further evidence for the possibility of associated radiocarpal ligament insufficiency after distal radius fracture.


Asunto(s)
Luxaciones Articulares , Fracturas del Radio , Fracturas del Cúbito , Fracturas de la Muñeca , Humanos , Estudios Retrospectivos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Fracturas del Radio/complicaciones , Fijación Interna de Fracturas/efectos adversos , Fracturas del Cúbito/diagnóstico por imagen , Fracturas del Cúbito/cirugía , Placas Óseas/efectos adversos , Resultado del Tratamiento
10.
BMC Musculoskelet Disord ; 25(1): 320, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654260

RESUMEN

BACKGROUND: The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures. METHODS: A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded. RESULTS: A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016). CONCLUSION: Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas del Radio , Humanos , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Adulto , Anciano , Resultado del Tratamiento , Estudios de Seguimiento , Estudios Retrospectivos , Rango del Movimiento Articular , Adulto Joven , Fracturas de la Muñeca
11.
Arch Orthop Trauma Surg ; 144(5): 2127-2129, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38494566

RESUMEN

INTRODUCTION: Time-efficiency of individually wrapped screws versus screws in a screw rack is not well established. MATERIALS AND METHODS: We performed a prospective single-center clinical study timing the interval between the surgeon asking and receiving a screw during plate and screw osteosynthesis of distal radius fractures. Patients were randomized for individually wrapped screws or screws in a screw rack. The study was conducted in a Level 1 Trauma Center and surgeries were performed between March and June 2023. RESULTS: Average handling time for screws from a screw rack was 9 s (SD 5.5; range 3-28) and 22 s for individually wrapped screws (SD 6.1; range 6-38). This average difference of 13 s is significant (p < 0.0001). CONCLUSION: There is a significant increase in handling time using individually wrapped screws over using a screw rack. LEVEL OF EVIDENCE: Level I (therapeutic, randomized controlled trial).


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas , Fracturas del Radio , Humanos , Fracturas del Radio/cirugía , Estudios Prospectivos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Tempo Operativo , Anciano de 80 o más Años , Fracturas de la Muñeca
12.
J Hand Surg Asian Pac Vol ; 29(2): 125-133, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38494162

RESUMEN

Background: We aim to evaluate the impact of advanced age and sex on postoperative complications and radiographic outcomes after open reduction with internal fixation of distal radius fractures (DRF). Methods: We conducted a retrospective chart review, including all patients who underwent open reduction with internal fixation of a DRF between 2012 and 2018 at a single level 1 trauma centre. We recorded patient age, sex, fracture classification (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA]), time from injury to surgical date, surgical duration, diabetes status, tobacco use, illicit drug use, history of osteoporosis, use of adjuvants, fixation type, postoperative radiographic restoration of normal parameters and early complications including loss of reduction within 30 days postoperatively. Advanced age was defined as age greater than 60 years. Results: A total of 521 patients underwent operative treatment - 264 males and 257 females. Males were twice as likely (23.5% vs. 10.1%; p < 0.0001) to sustain a type C3 fracture and be treated with a wrist spanning plate (5.3% vs. 0; p < 0.0001). A larger percentage of elderly patients undergoing operative treatment of DRF were female (20.2% vs. 5.7%; p < 0.0001) and females were more likely to carry a pre-injury diagnosis of osteoporosis (9.3% vs. 0%; p < 0.0001). And 100% of the elderly patients received were treated with a volar plate. The overall early loss of reduction was 7.5%. The overall complication rate was 8.2%. No differences in early postoperative complications were identified between sexes or age groups. Neither female sex nor advanced age was found to have increased risk of postoperative complications or early loss of reduction. Similar postoperative radiographic parameter measurements were obtained across groups as well. Conclusions: Our results support the idea that operative treatment of unstable DRF in elderly patients and women is a reasonable treatment option without significant increases in early postoperative complications. Level of Evidence: Level III (Therapeutic III).


Asunto(s)
Osteoporosis , Fracturas del Radio , Fracturas de la Muñeca , Masculino , Humanos , Femenino , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/epidemiología , Fracturas del Radio/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
13.
Hand Surg Rehabil ; 43(2): 101674, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38431044

RESUMEN

OBJECTIVES: The relationship between volar fragment size and postoperative volar tilt loss in complete articular distal radius fracture is not well known. In this study, we measured precise radiological parameters to help identify other factors that might contribute to volar tilt loss. MATERIAL AND METHODS: We retrospectively reviewed the radiological examinations and charts of 256 patients with distal radial fracture who underwent volar locking plate fixation between March 2014 and July 2022. Radiological parameters were measured based on preoperative CT and immediate postoperative radiographs. Univariate and multivariate linear regression analysis was performed to identify relevant factors associated with volar tilt loss following volar locking plate fixation. The receiver operating characteristic curve was used to identify the cutoff value of the independent parameters. RESULTS: On univariate analysis, 2 radiologic parameters on preoperative CT (volar fragment length at the lunate fossa, and teardrop angle) and 4 on immediate postoperative X-ray (radial inclination, radial length, capitate shift, and volar tilt) were significantly associated with postoperative volar tilt loss. On multivariate linear regression analysis, the risk of volar tilt loss increased as the capitate moved toward the back of the radial shaft. The cut-off for anteroposterior length in the lunate fossa was 6.5 mm. CONCLUSIONS: AO/OTA type-C distal radius fractures with <6.5 mm anteroposterior length in the lunate fossa had significantly higher rates of malunion with dorsal deformity. In addition, preoperative teardrop angle <37.2 ° and immediate postoperative volar tilt <3.7º are also predictors of postoperative volar tilt loss.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas del Radio , Humanos , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Tomografía Computarizada por Rayos X , Hueso Semilunar/diagnóstico por imagen , Hueso Semilunar/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/diagnóstico por imagen , Fracturas de la Muñeca
14.
BMC Musculoskelet Disord ; 25(1): 228, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509566

RESUMEN

BACKGROUND: Surgical treatment of irreducible distal radius diaphyseal- metaphyseal junction fractures involves difficulties as the fracture remains too proximal for K-wire fixation and too distal for the elastic stable intramedullary nail. Our study aims to present the clinical results of applying an elastic stable intramedullary nail with a poller K-wire to achieve both reduction and stable fixation. PATIENTS AND METHODS: A retrospective analysis was performed on 26 patients who underwent ESIN with a poller K-wire for distal radius diaphyseal-metaphyseal region fracture. Reduction parameters such as residual angulation and alignment were evaluated on postoperative follow-up radiographs. Changes in angular and alignment parameters on follow-up radiographs were recorded. Wrist and forearm functions were evaluated at the last follow-up. RESULT: There were 17 male and nine female patients with an average age of 10.9. The residual angulation in coronal and sagittal planes on immediate postoperative radiographs was 4.0 ± 1.62° and 3.0 ± 1.26°, respectively. The mean translation rate on immediate postoperative radiographs was 6.0 ± 1.98% and 5.0 ± 2.02% in the coronal and sagittal planes, respectively. No change was observed in translation rates in the last follow-ups. The mean angulation in the coronal and sagittal planes measured on 6th-week radiographs was 4.0 ± 1.72°and 3.0 ± 1.16°, respectively. No significant difference was observed in angular changes in the sagittal and coronal planes at the last follow-up (p > 0.05). No tendon injury or neurovascular injury was observed in any of the patients. CONCLUSION: In the surgical treatment of pediatric DRDMJ fractures, applying ESIN with poller K-wire is an effective, safe, and novel method for achieving reduction and stable fixation.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas del Radio , Humanos , Niño , Masculino , Femenino , Estudios Retrospectivos , Radio (Anatomía) , Fijación Intramedular de Fracturas/métodos , Hilos Ortopédicos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Fracturas del Radio/etiología , Resultado del Tratamiento , Clavos Ortopédicos
15.
BMC Musculoskelet Disord ; 25(1): 217, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491493

RESUMEN

Traditionally, the assessment of distal radius fracture outcomes has been based on radiological measurements and self-evaluation scores. However, there is uncertainty regarding how accurately these measurements reflect the patient's perception of their outcome. In this study, we examined the correlation between radiological measurements and patient-perceived outcomes using the Disabilities of the Arm, Shoulder, and Hand outcome (DASH) score. 140 individuals who had recovered from a distal radius fracture. and had been treated with DVR, Kapandji, percutaneous pinning or closed reduction were included in the study. The retrospective assessment included 78 females and 62 males, with a mean DASH score of 3.54 points.Except for the ulnar variance, the study found little to no significant association between the DASH score and the final radiological measurement.In summary, the DASH score did not always indicate that a superior radiological result translated into a better patient-perceived outcome.


Asunto(s)
Fracturas del Radio , Fracturas de la Muñeca , Traumatismos de la Muñeca , Masculino , Femenino , Humanos , Muñeca , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Estudios Retrospectivos , Articulación de la Muñeca , Traumatismos de la Muñeca/diagnóstico por imagen , Traumatismos de la Muñeca/cirugía , Rango del Movimiento Articular , Fijación Interna de Fracturas , Placas Óseas , Resultado del Tratamiento
16.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241236806, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38430070

RESUMEN

PURPOSE: To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures. MATERIAL AND METHODS: This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated. RESULTS: The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation. CONCLUSION: The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.


Asunto(s)
Articulación del Codo , Prótesis de Codo , Fracturas del Radio , Masculino , Humanos , Femenino , Adulto , Estudios Prospectivos , Titanio , Implantación de Prótesis , Articulación del Codo/cirugía , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Impresión Tridimensional , Resultado del Tratamiento , Rango del Movimiento Articular , Estudios Retrospectivos
17.
Ann Ital Chir ; 95(1): 78-90, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38469615

RESUMEN

BACKGROUND: To compare the clinical effects between wrist arthroscopy-assisted open reduction plus internal fixation, using the triangular fibrocartilage complex (TFCC) as an example, and simple open reduction plus internal fixation in the treatment of distal radius fractures (DRFs). The study aims to assess the efficacy of arthroscopic-assisted open reduction and internal fixation in treating distal radius fractures. METHODS: The study utilized a retrospective cohort research approach, involving 60 patients treated at Binzhou Medical University Hospital between August 2021 and October 2022. These patients met the specified criteria and underwent two distinct surgical procedures for DRFs. Prior to surgery, thorough communication was established with the patients to elucidate the advantages, risks, and associated costs of wrist arthroscopy, and informed consent was obtained. Subsequent to the surgeries, postoperative follow-up was conducted to evaluate the variances between the two treatment modalities. Postoperative analysis and assessment encompassed the patients' Visual Analogue Scale (VAS) scores, Cooney wrist scores, grip strength of the affected limb (in comparison with the healthy side), wrist range of motion, and the frequency of intraoperative fluoroscopy usage. RESULTS: No surgical complications were observed among all patients. They were followed up for an average duration of (12.1 ± 1.3) months postoperatively, during which all fractures healed successfully. Within the treatment group, arthroscopy detected 14 cases of TFCC tears during the operation, all of which were repaired under a microscope. Conversely, physical examination identified three cases of TFCC injury in the control group, which were treated via incision and suture. At the 3-month postoperative mark, the treatment group exhibited significantly superior comprehensive scores for wrist pain, grip strength, and wrist range of motion compared to the control group (p < 0.05). Cooney's comprehensive wrist joint scoring yielded the following results: treatment group - excellent in 21 cases, good in five cases, and moderate in four cases; control group - excellent in 16 cases, good in nine cases, and moderate in five cases. CONCLUSION: Wrist arthroscopy-assisted surgery facilitates precise reduction of the articular surface and alleviation of intraarticular congestion. Moreover, it enables evaluation and repair of concurrent intra-articular injuries such as TFCC tears and other tissue injuries, thereby reducing the likelihood of chronic wrist pain. Consequently, this technique should be deemed valuable in clinical practice owing to its outstanding clinical efficacy.


Asunto(s)
Fracturas del Radio , Fibrocartílago Triangular , Fracturas de la Muñeca , Traumatismos de la Muñeca , Humanos , Fibrocartílago Triangular/cirugía , Fibrocartílago Triangular/lesiones , Muñeca , Artroscopía/métodos , Estudios Retrospectivos , Traumatismos de la Muñeca/cirugía , Fracturas del Radio/cirugía , Articulación de la Muñeca/cirugía , Resultado del Tratamiento , Dolor
18.
Artículo en Inglés | MEDLINE | ID: mdl-38530958

RESUMEN

BACKGROUND: Little is known about the burden or management of distal radius fractures (DRFs) in low- and middle-income countries. The purpose of this study was to describe the care of DRFs in Malawi. METHODS: We retrospectively reviewed a registry of all patients with fractures who presented to the orthopaedic departments at four public hospitals in Malawi. RESULTS: Totally, 1,440 patients (14.5%) were with a DRF. Average age was 40, and 888 (62.0%) were male. Surgery was done for 122 patients (9.5%). Patients presenting to Queen Elizabeth Hospital, patients presenting after a fall, and patients initially evaluated by an orthopaedic registrar or orthopaedic clinical officer had lower odds of receiving surgical treatment. Meanwhile, open injuries had the greatest odds of receiving surgery. CONCLUSION: The most common musculoskeletal injury among patients in the Malawi Fracture Registry was fractures of the distal radius. These most affected young adult male patients may benefit from surgery; however, the majority were managed nonsurgically. Lack of access to surgical fixation and conservative follow-up may have long-term functional consequences in a predominantly agrarian society. Outcomes-based research is needed to help guide management decisions and standardize patient care and referral protocols.


Asunto(s)
Fracturas del Radio , Fracturas de la Muñeca , Adulto Joven , Humanos , Masculino , Femenino , Fracturas del Radio/cirugía , Estudios Retrospectivos , Malaui , Hospitales Públicos
19.
Zhongguo Gu Shang ; 37(3): 311-5, 2024 Mar 25.
Artículo en Chino | MEDLINE | ID: mdl-38515421

RESUMEN

OBJECTIVE: To explore clinical effect of precast curvature internal fixation with Kirschner needle in treating forearm fracture in children. METHODS: From October 2019 to December 2022,32 children with forearm fractures were treated with precast curvature internal fixation with Kirkler's needles,including 25 males and 7 females,aged from 3 to 15 years old with an average of (8.0±0.5) years old,18 patients on the left side and 14 on the right side,24 patients with double fractures of radial and ulna,3 patients with Monteggia fractures,and 4 patients with Galeazzi fractures,and 1 patient with radial neck fracture of crooked cap. Operation time,intraoperative blood loss,C-arm fluoroscopy,fracture healing time and complications were recorded,and disabilities of arm,shoulder and hand (DASH) scale and Grace-Eversman forearm double fracture evaluation system were used to evaluate clinical efficacy of precast curvature internal fixation with Kirschner's needle for forearm fracture in children. RESULTS: All 32 patients were followed up for 2 to 12 months with an average of (7.16±2.51) months. Intraoperative blood loss was (20.68±5.50) ml,C-arm fluoroscopy was(5.80±2.50),and operation time was (24.34±5.10) min,fracture healing time was (8.82±1.62) weeks. Two patients occurred complications,including postoperative rupture of extensor pollicis longus tendon in 1 patient and obvious displacement of fracture caused by rotation of prefabricated curvature Kirschler needle on bone marrow cavity in 1 patient. DASH scores ranged from 0 to 16 scores with an average of (8.32±1.50) scores. According to Grace-Eversman double fracture evaluation system,28 patients got excellent result,2 good and 2 fair. CONCLUSION: The treatment of forearm fracture with Kirschner's needle prefabricated curvature internal fixation has advantages of less trauma,less bleeding,good reduction,stable fixation,fast fracture healing and good functional recovery.


Asunto(s)
Antebrazo , Fracturas del Radio , Masculino , Niño , Femenino , Humanos , Preescolar , Adolescente , Pérdida de Sangre Quirúrgica , Fijación Interna de Fracturas , Fracturas del Radio/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Hilos Ortopédicos
20.
Ulus Travma Acil Cerrahi Derg ; 30(2): 135-141, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38305653

RESUMEN

BACKGROUND: Although isolated distal radius and radial head fractures are common injuries, simultaneous ipsilateral fractures are uncommon. They can range from simple undisplaced fractures at either end to severely comminuted ipsilateral proximal and distal radial fractures. Few cases have been reported with concomitant comminuted distal radius and radial head fractures, and no treatment guidelines are available. Decisions are often based on personal recommendations. The purpose of our study is to increase awareness of this injury pattern and to discuss the mechanism of injury, treatment approach, and functional outcome. METHODS: Skeletally mature patients with comminuted simultaneous ipsilateral fractures of the distal and proximal radius from 2016 to 2021 were identified and studied retrospectively. Demographic information, mechanism of injury, treatment approach, and complication rate were analyzed. Radiographic assessment for inadequacy or loss of reduction and radiographic parameters of the distal radius, including radial inclination, radial length, and palmar inclination, was performed immediately postoperatively and at the final follow-up. Clinical outcomes were determined by calculating the Visual Analog Scale (VAS) score, measuring the range of motion in both joints, and using the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score at the final follow-up. RESULTS: A total of 11 patients met the inclusion criteria. All had ipsilateral Mason III radial head fractures and type C (according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification) intra-articular distal radius fracture. On-table radial head reconstruction and fixation with a proximal radius plate were used for radial head fractures, and osteosynthesis with an anatomic volar locking plate was used for distal radius fractures. The mean follow-up duration was 32 months (range 12-65 months). At the final follow-up, osseous union of both the radial head and distal radius was observed in all patients. The mean VAS score was 1.5 (range 0-7) at rest and 3.9 (range 0-9) with activities, while the mean QuickDASH score was 32 (range 12-65). No significant complications were recorded. CONCLUSION: Simultaneous comminuted fractures of the ipsilateral distal radius and radial head represent a distinct injury pattern, most likely resulting from high-energy trauma, such as falling from a height onto an outstretched hand. Greater emphasis should be placed on clinical examination and radiological imaging of the elbow in cases of wrist injuries and vice versa. Treatment involving on-table reconstruction of the radial head and open reduction and internal fixation with a volar plate can lead to good radiological and functional outcomes.


Asunto(s)
Fracturas Conminutas , Fracturas Radiales de Cabeza y Cuello , Fracturas del Radio , Humanos , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Radio (Anatomía)/lesiones , Fracturas Conminutas/diagnóstico por imagen , Fracturas Conminutas/cirugía , Estudios Retrospectivos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Fijación Interna de Fracturas/métodos , Rango del Movimiento Articular , Placas Óseas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA