Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.055
Filtrar
1.
Rev Col Bras Cir ; 51: e20243670, 2024.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-38716916

RESUMEN

INTRODUCTION: Abdominal wall hernias encompass both ventral and incisional hernias, often poorly classified regarding complexity in general. This study aims to conduct a review on the primary topics related to defining the complexity of ventral hernias. METHODS: this is a scope review conducted following the guidelines recommended by the PRISMA-ScR directive. Searches were carried out in electronic databases including PubMed, LILACS, and EMBASE, using the descriptors: Abdominal Hernia, Hernia, Ventral Hernia, Incisional Hernia, Complex, Classification, Classify, Grade, Scale, and Definition. Combinations of these terms were employed when appropriate. Inclusion criteria encompassed articles with definitions and classifications of complex hernias, as well as those utilizing these classifications to guide treatments and patient allocation. Synonyms and related topics were also considered. Articles outside the scope or lacking the themes in their title or abstract were excluded. The database search was conducted up to July 29, 2023. RESULTS: several hernia classifications were identified as useful in predicting complexity. For this study, we considered six main criteria: size and location, loss of domain, use of abdominal wall relaxation techniques, characteristics of imaging exams, status of the subcutaneous cellular tissue, and likelihood of recurrence. CONCLUSION: complex abdominal wall hernias can be defined by characteristics analyzed collectively, relating to the patients previous clinical status, size and location of the hernia defect, status of subcutaneous cellular tissue, myofascial release techniques, and other complicating factors.


Asunto(s)
Hernia Ventral , Humanos , Hernia Ventral/clasificación , Hernia Ventral/cirugía , Hernia Ventral/diagnóstico , Hernia Incisional/cirugía , Pared Abdominal , Recurrencia
2.
Langenbecks Arch Surg ; 409(1): 164, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38775920

RESUMEN

PURPOSE: To explore the risk factors for incisional hernia (IH) recurrence following open prepertioneal repair. METHODS: Patients diagnosed with primary IH who underwent open preperitoneal repair at our hospital were enrolled. Patients were assessed, and perioperative factors were collected. Recurrence surveys were performed at regular intervals throughout the long-term postoperative follow-up. The risk factors for IH recurrence were identified using univariate and multivariate analyses. RESULTS: This study included 145 patients. Significant differences were found between recurrence and non-recurrence patients regarding pulmonary ventilation function (PVT), age, body mass index (BMI), mesh materials, type of surgery (clean, clean-contaminated, or contaminated), surgical site infections (SSIs), maximum width of the hernia defect (MWHD), and site of incisional hernia (P < 0.01). The univariate survival analysis revealed that PVT abnormalities, age > 70 years, BMI > 27 kg/m2, porcine small intestine submucosal (PSIS) mesh, non-clean surgery, SSIs, MWHD > 10 cm, and location in the lateral zones were significant factors for IH recurrence after open preperitoneal repair. The multivariate survival analysis showed that PVT abnormalities, age > 70 years, BMI > 27 kg/m2, and PSIS mesh were independent risk factors for IH recurrence after open preperitoneal repair. CONCLUSIONS: We identified PVT abnormalities, age > 70 years, BMI > 27 kg/m2, and PSIS mesh as novel risk factors for IH recurrence after open preperitoneal repair.


Asunto(s)
Herniorrafia , Hernia Incisional , Recurrencia , Mallas Quirúrgicas , Humanos , Masculino , Femenino , Hernia Incisional/cirugía , Hernia Incisional/etiología , Estudios Retrospectivos , Factores de Riesgo , Anciano , Persona de Mediana Edad , Herniorrafia/efectos adversos , Herniorrafia/métodos , Adulto , Estudios de Cohortes , Anciano de 80 o más Años
3.
Colorectal Dis ; 26(5): 1014-1027, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38561871

RESUMEN

AIM: The aim was to examine the quality of online patient information resources for patients considering parastomal hernia treatment. METHODS: A Google search was conducted using lay search terms for patient facing sources on parastomal hernia. The quality of the content was assessed using the validated DISCERN instrument. Readability of written content was established using the Flesch-Kincaid score. Sources were also assessed against the essential content and process standards from the National Institute for Health and Care Excellence (NICE) framework for shared decision making support tools. Content analysis was also undertaken to explore what the sources covered and to identify any commonalities across the content. RESULTS: Fourteen sources were identified and assessed using the identified tools. The mean Flesch-Kincaid reading ease score was 43.61, suggesting that the information was difficult to read. The overall quality of the identified sources was low based on the pooled analysis of the DISCERN and Flesch-Kincaid scores, and when assessed against the criteria in the NICE standards framework for shared decision making tools. Content analysis identified eight categories encompassing 59 codes, which highlighted considerable variation between sources. CONCLUSIONS: The current information available to patients considering parastomal hernia treatment is of low quality and often does not contain enough information on treatment options for patients to be able to make an informed decision about the best treatment for them. There is a need for high-quality information, ideally co-produced with patients, to provide patients with the necessary information to allow them to make informed decisions about their treatment options when faced with a symptomatic parastomal hernia.


Asunto(s)
Internet , Educación del Paciente como Asunto , Humanos , Información de Salud al Consumidor/normas , Estomas Quirúrgicos/efectos adversos , Hernia Incisional/cirugía , Comprensión , Herniorrafia
5.
Surg Endosc ; 38(5): 2850-2856, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38568440

RESUMEN

BACKGROUND: This study aims to compare clinical outcomes and financial cost of intraperitoneal onlay mesh (IPOM) versus retromuscular (RM) repairs in robotic incisional hernia repairs (rIHR). METHODS: Patients who underwent either IPOM or RM elective rIHR from 2012 to 2022 were included. Demographics, operative details, postoperative outcomes, and hospital costs were directly compared. RESULTS: Sixty-nine IPOM and 55 RM were included. Age and body mass index (BMI) did not differ between both groups (IPOM vs RM: 59.3 ± 11.2 years vs. 57.5 ± 14 years, p = 0.423; BMI 34.1 ± 6.3 vs. BMI 33.2 ± 6.9, p = 0.435, respectively). Comorbidities and hernia characteristics were comparable. Extensive lysis of adhesions (> 30 min) was required more often in IPOM (18 vs. 6 in RM, p = 0.034). Defect closure was achieved in 100% of RM vs. 81.2% in IPOM (p < 0.001). Median (interquartile range) postoperative pain score was higher in RM than in IPOM [5(3-7) vs. 4(3-5), respectively, p = 0.006]. Median length of stay (0 day) and same-day discharge rate did not differ between groups (p = 0.598, p = 0.669, respectively). Six (8.7%) patients in the IPOM group versus one (1.8%) patient in the RM group were readmitted to hospital within 30 days postoperatively (p = 0.099). Perioperative complications were higher in IPOM (p = 0.011; 34.8% vs. 14.5% in RM) with higher Comprehensive Complication Index® morbidity scores [0(0-12.2) vs 0(0-0) in RM, p = 0.008)], Clavien-Dindo grade-II complications (8 vs 0 in RM, p = 0.009), and surgical site events (17 vs. 5 in RM, p = 0.024). Within a follow-up period of 57(± 28) months, recurrence rates were similar between both groups. Hospital costs did not differ between groups [IPOM: $9978 (7031-12,926) vs. RM: $8961(6701-11,222), p = 0.300]. Although postoperative complication costs were higher in IPOM ($2436 vs RM: $161, p = 0.020), total costs were comparable [IPOM: $12,415(8700-16,130) vs. RM: $9123(6789-11,457), p = 0.080]. CONCLUSION: Despite retromuscular repairs having lower postoperative complications than intraperitoneal onlay mesh repairs, both techniques offered encouraging results in robotic incisional hernia repair at a comparable total cost.


Asunto(s)
Herniorrafia , Hernia Incisional , Procedimientos Quirúrgicos Robotizados , Mallas Quirúrgicas , Humanos , Procedimientos Quirúrgicos Robotizados/economía , Procedimientos Quirúrgicos Robotizados/métodos , Persona de Mediana Edad , Mallas Quirúrgicas/economía , Femenino , Masculino , Herniorrafia/métodos , Herniorrafia/economía , Hernia Incisional/cirugía , Hernia Incisional/economía , Anciano , Resultado del Tratamiento , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Costos de Hospital/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos
6.
Updates Surg ; 76(3): 1115-1119, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38573448

RESUMEN

Parastomal hernia (PSH) is a prevalent long-term morbidity associated with stoma construction, and the optimal operative management remains uncertain. This study addresses the need for a standardized approach to symptomatic PSH repair, focusing on the robotic-assisted modified Sugarbaker technique with composite permanent mesh. The study, conducted in a high-volume colon and rectal surgery referral practice, outlines a systematic approach to patient selection, surgical procedures, and postoperative care. Preoperative evaluations include detailed medical and surgical histories, impact assessments of PSH, and oncological history reviews. The surgical technique involves the Da Vinci Xi™ robotic platform for adhesiolysis, hernia content reduction, stoma revision if needed, narrowing of the enlarged stoma trephine, lateralization of the stoma limb of bowel, and securing the mesh to the abdominal wall. Outcomes are reported for 102 patients undergoing robotic parastomal hernia repair from January 2021 to July 2023. Conversion to open surgery occurred in only one case (0.9%). Postoperative complications affected 39.2% of patients, with ileus being the most frequent (24.5%). Recurrence was observed in 5.8% of cases during an average follow-up of 10 months. In conclusion, parastomal hernia, a common complication post-stoma creation, demands surgical intervention. The robotic-assisted modified Sugarbaker repair technique, as outlined in this paper, offers promising results in terms of feasibility and outcomes.


Asunto(s)
Herniorrafia , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Robotizados , Mallas Quirúrgicas , Estomas Quirúrgicos , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Herniorrafia/métodos , Estomas Quirúrgicos/efectos adversos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Hernia Incisional/cirugía , Resultado del Tratamiento , Recurrencia , Anciano de 80 o más Años , Hernia Ventral/cirugía
8.
Surg Endosc ; 38(6): 3052-3060, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38609586

RESUMEN

BACKGROUND: One in two ventral and incisional hernia repair (VIHR) patients have preoperative opioid prescription within a year before procedure. The study's aim was to investigate risk factors of increased postoperative prescription filling in patients with or without preoperative opioid prescription. METHODS: VIHR cases from 2013 to 2017 were reviewed. State prescription drug monitoring program data were linked to patient records. The primary endpoint was cumulative opioid dose dispensed through post-discharge day 45. Morphine milligram equivalent (MME) was used for uniform comparison. RESULTS: 205 patients were included in the study (average age 53.5 years; 50.7% female). Over 35% met criteria for preoperative opioid use. Preoperative opioid tolerance, superficial wound infection, current smoking status, and any dispensed opioids within 45 days of admission were independent predictors for increased postoperative opioid utilization (p < 0.001). CONCLUSION: Preoperative opioid use during 45-day pre-admission correlated strongly with postoperative prescription filling in VIHR patients, and several independent risk factors were identified.


Asunto(s)
Analgésicos Opioides , Hernia Ventral , Herniorrafia , Hernia Incisional , Dolor Postoperatorio , Humanos , Femenino , Analgésicos Opioides/uso terapéutico , Analgésicos Opioides/administración & dosificación , Persona de Mediana Edad , Masculino , Dolor Postoperatorio/tratamiento farmacológico , Hernia Incisional/cirugía , Hernia Ventral/cirugía , Herniorrafia/métodos , Herniorrafia/efectos adversos , Factores de Riesgo , Estudios Retrospectivos , Anciano , Adulto
9.
BMJ Open ; 14(4): e081046, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38626979

RESUMEN

INTRODUCTION: Incisional hernia (IH) is a prevalent and potentially dangerous complication of abdominal surgery, especially in high-risk groups. Mesh reinforcement of the abdominal wall has been studied as a potential intervention to prevent IHs. Randomised controlled trials (RCTs) have demonstrated that prophylactic mesh reinforcement after abdominal surgery, in general, is effective and safe. In patients with abdominal aortic aneurysm (AAA), prophylactic mesh reinforcement after open repair has not yet been recommended in official guidelines, because of relatively small sample sizes in individual trials. Furthermore, the identification of subgroups that benefit most from prophylactic mesh placement requires larger patient numbers. Our primary aim is to evaluate the efficacy and effectiveness of the use of a prophylactic mesh after open AAA surgery to prevent IH by performing an individual patient data meta-analysis (IPDMA). Secondary aims include the evaluation of postoperative complications, pain and quality of life, and the identification of potential subgroups that benefit most from prophylactic mesh reinforcement. METHODS AND ANALYSIS: We will conduct a systematic review to identify RCTs that study prophylactic mesh placement after open AAA surgery. Cochrane Central Register of Controlled Trials, MEDLINE Ovid, Embase, Web of Science Core Collection and Google Scholar will be searched from the date of inception onwards. RCTs must directly compare primary sutured closure with mesh closure in adult patients who undergo open AAA surgery. Lead authors of eligible studies will be asked to share individual participant data (IPD). The risk of bias (ROB) for each included study will be assessed using the Cochrane ROB tool. An IPDMA will be performed to evaluate the efficacy, with the IH rate as the primary outcome. Any signs of heterogeneity will be evaluated by Forest plots. Time-to-event analyses are performed using Cox regression analysis to evaluate risk factors. ETHICS AND DISSEMINATION: No new data will be collected in this study. We will adhere to institutional, national and international regulations regarding the secure and confidential sharing of IPD, addressing ethics as indicated. We will disseminate findings via international conferences, open-source publications in peer-reviewed journals and summaries posted online. PROSPERO REGISTRATION NUMBER: CRD42022347881.


Asunto(s)
Aneurisma de la Aorta Abdominal , Hernia Incisional , Adulto , Humanos , Hernia Incisional/prevención & control , Hernia Incisional/cirugía , Mallas Quirúrgicas , Complicaciones Posoperatorias/etiología , Laparotomía/efectos adversos , Aneurisma de la Aorta Abdominal/cirugía , Revisiones Sistemáticas como Asunto , Metaanálisis como Asunto
10.
Biomed Mater ; 19(3)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38604155

RESUMEN

The standard surgical procedure for abdominal hernia repair with conventional prosthetic mesh still results in a high recurrence rate. In the present study, we propose a fibroblast matrix implant (FMI), which is a three-dimensional (3D) poly-L-lactic acid scaffold coated with collagen (matrix) and seeded with fibroblasts, as an alternative mesh for hernia repair. The matrix was seeded with fibroblasts (cellularized) and treated with a conditioned medium (CM) of human Umbilical Cord Mesenchymal Stem Cells (hUC-MSC). Fibroblast proliferation and function were assessed and compared between treated with CM hUC-MSC and untreated group, 24 h after seeding onto the matrix (n= 3). To study the matricesin vivo,the hernia was surgically created on male Sprague Dawley rats and repaired with four different grafts (n= 3), including a commercial mesh (mesh group), a matrix without cells (cell-free group), a matrix seeded with fibroblasts (FMI group), and a matrix seeded with fibroblasts and cultured in medium treated with 1% CM hUC-MSC (FMI-CM group).In vitroexamination showed that the fibroblasts' proliferation on the matrices (treated group) did not differ significantly compared to the untreated group. CM hUC-MSC was able to promote the collagen synthesis of the fibroblasts, resulting in a higher collagen concentration compared to the untreated group. Furthermore, thein vivostudy showed that the matrices allowed fibroblast growth and supported cell functionality for at least 1 month after implantation. The highest number of fibroblasts was observed in the FMI group at the 14 d endpoint, but at the 28 d endpoint, the FMI-CM group had the highest. Collagen deposition area and neovascularization at the implantation site were observed in all groups without any significant difference between the groups. FMI combined with CM hUC-MSC may serve as a better option for hernia repair, providing additional reinforcement which in turn should reduce hernia recurrence.


Asunto(s)
Proliferación Celular , Colágeno , Fibroblastos , Herniorrafia , Hernia Incisional , Células Madre Mesenquimatosas , Ratas Sprague-Dawley , Mallas Quirúrgicas , Andamios del Tejido , Animales , Fibroblastos/metabolismo , Ratas , Masculino , Humanos , Células Madre Mesenquimatosas/citología , Herniorrafia/métodos , Herniorrafia/instrumentación , Colágeno/química , Andamios del Tejido/química , Hernia Incisional/cirugía , Poliésteres/química , Ensayo de Materiales , Medios de Cultivo Condicionados/farmacología , Materiales Biocompatibles/química , Células Cultivadas , Hernia Abdominal/cirugía , Cordón Umbilical/citología
11.
Ann Plast Surg ; 92(4S Suppl 2): S156-S160, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556666

RESUMEN

INTRODUCTION: The ideal mesh type for hernia repair in a contaminated field remains controversial. Data regarding outcomes beyond 1 year and the impact on quality of life (QoL) are unknown. This study aims to evaluate the long-term surgical outcomes and patient-reported outcomes (PROs) after contaminated repair with poly-4-hydroxybutyrate (P4HB) mesh. MATERIALS METHODS: Patients undergoing a contaminated hernia repair with P4HB between 2015 and 2020 were identified. Surgical site occurrences and hernia recurrences were recorded. Long-term PROs as defined by the Abdominal Hernia-Q and Hernia-Related Quality-of-Life Survey were assessed. RESULTS: Fifty-five patients were included with a mean age of 54.5 years, a body mass index of 34 kg/m2, and a defect size of 356.9 ± 227.7 cm2. Median follow-up time was 49 months with a reoperation rate of 14.5% and a hernia recurrence rate of 7.3%. Of the 55 patients, 37 completed preoperative and postoperative PRO questionnaires. When comparing preoperative with postoperative Abdominal Hernia-Q, there was significant improvement in overall PROs (2.1 vs 3.5, P < 0.001). This improvement was maintained with no significant changes between postoperative scores over the course of 5 years. Patients with complications saw the same improvement in postoperative PRO scores as those without complications. CONCLUSIONS: Our study found a low hernia recurrence and acceptable long-term reoperation rates in patients undergoing hernia repair with P4HB mesh in a contaminated setting. We demonstrate a sustained significant improvement in QoL scores after hernia repair. These data yield insight into the long-term outcomes and QoL improvement, providing physicians further knowledge to better counsel their patients.


Asunto(s)
Hernia Ventral , Hernia Incisional , Humanos , Persona de Mediana Edad , Calidad de Vida , Herniorrafia/efectos adversos , Resultado del Tratamiento , Infección de la Herida Quirúrgica/etiología , Mallas Quirúrgicas/efectos adversos , Hernia Ventral/cirugía , Hernia Incisional/cirugía , Recurrencia , Estudios Retrospectivos
13.
Chirurgia (Bucur) ; 119(1): 102-105, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465720

RESUMEN

video width="640" height="480" controls controlsList="nodownload" poster="https://www.revistachirurgia.ro/pdfs/video/Victor_Gheorghe_Radu_L3W3_Incisional_Hernia.jpg" style="margin-top: -20px;" source src="https://www.revistachirurgia.ro/pdfs/video/Victor_Gheorghe_Radu_L3W3_Incisional_Hernia.mp4" type="video/mp4" Your browser does not support the video tag. /video Introduction: The Rives-Stoppa procedure has emerged as the preferred method for ventral hernia repair, and the principles of this technique are similarly applied in minimally invasive surgery using the eTEP (enhanced view totally extraperitoneal) approach. It appears that the eTEP approach offers excellent outcomes in terms of less post-operative pain, faster recovery, and shorter hospital stays for patients undergoing abdominal wall reconstruction (AWR). It's important to note that there are some contra-indications of this procedure. In general, laparoscopic eTEP may not be suitable for cases with large hernias and loss of domain where the working space is limited. In such cases, alternative approaches, such as using a robotic platform, may be considered to ensure an adequate working space for abdominal wall reconstruction (AWR). A robotic platform can create a working space by using the robotic arms as a "laparo-lift," enabling the AWR to be performed. Case Report: In this case, we have a 65-year-old female patient with a BMI of 28.5 who presents with a large incisional hernia with LOD. This hernia is located on the right flank and occurred after a Jalaguier incision. The CT scan provided valuable information regarding the size of the hernia, the remaining volume of the abdominal cavity, and the content of the hernia sac. Based on these radiological details, the LOD diagnosis was confirmed using the Sabbagh equation, which revealed that the hernia volume accounted for 46.47% of the total peritoneal volume. Based on the location, size of the defect, and the EHS classification for incisional hernias, the diagnosis for this case is a Complex incisional hernia of L3 right W3 with LOD. The protocol for optimization in this case involves chemo-relaxation, which refers to the injection of botulinum toxin A (BTA) into the large lateral muscles of the abdomen. This is done approximately 6 weeks before the surgery. Based on the successful reduction of the hernia during the consultation, the decision has been made to perform the Abdominal Wall Reconstruction (AWR) procedure using the robotic eTEP-TAR technique. Conclusion: The post-operative course was favorable, with the patient experiencing early active mobilization, reduced pain, and early return of bowel movement. The patient was discharged the day after the surgery.


Asunto(s)
Hernia Ventral , Hernia Incisional , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Femenino , Humanos , Anciano , Hernia Incisional/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Resultado del Tratamiento , Hernia Ventral/cirugía , Músculos Abdominales/cirugía , Laparoscopía/métodos , Herniorrafia/métodos , Mallas Quirúrgicas
14.
Surg Endosc ; 38(4): 2260-2266, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38438671

RESUMEN

BACKGROUND: Though robotic adoption for eTEP surgery has decreased technical barriers to minimally invasive repairs of large ventral hernias, relatively few studies have examined outcomes of robotic-specific eTEP surgery. This study evaluates safety, feasibility, and early outcomes of ERAS/same-day discharge protocols for robotic eTEP ventral hernia repairs. METHODS: A retrospective chart review was performed for all robotic eTEP hernia surgeries at a single institution between 2019 and 2022. Analysis included patient demographics, hernia characteristics, intraoperative data, and post-operative outcomes at 30 days. ERAS protocol included: judicious use of urinary catheters with removal at end of case if placed, bilateral transversus abdominus plane (TAP) blocks, post-operative abdominal wall binder, and opioid-sparing perioperative analgesia. Patients were discharged same day from post-anesthesia care unit (PACU) if they lacked comorbidities requiring observation post-anesthesia and demonstrated stable vital signs, adequate pain control, ability to void, and ability to ambulate. Hospital length of stay (LOS) was considered 0 for same-day PACU discharges or hospitalizations < 24 h. RESULTS: 102 patients were included in this case series. 69% (70/102) of patients were discharged same-day (mean LOS 0.47 ± 0.80 days). Within 30 post-operative days, 3% (3/102) of patients presented to the ER, 2% (2/102) were readmitted to the hospital, and 1% (1/102) required reoperation. There was 1 serious complication (Clavien-Dindo grade 3/4) with an aggregate complication rate of 7.8%. CONCLUSIONS: Our initial experience with ERAS protocols and same-day discharges after robotic eTEP repair demonstrates this approach is safe and feasible with acceptable short-term patient outcomes. Compared to traditional open surgery for large ventral hernias, robotic eTEP may enable significant reductions in hospital LOS as adoption increases.


Asunto(s)
Recuperación Mejorada Después de la Cirugía , Hernia Ventral , Hernia Incisional , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Humanos , Alta del Paciente , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Hernia Ventral/cirugía , Herniorrafia/métodos , Hernia Incisional/cirugía , Mallas Quirúrgicas , Laparoscopía/métodos
15.
Surg Endosc ; 38(4): 2197-2204, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38448624

RESUMEN

BACKGROUND: The eTEP Rives-Stoppa (RS) procedure, increasingly used for ventral hernia repair, has raised concerns about postoperative upper abdominal bulging. This study aims to objectively evaluate changes in the abdominal contour after eTEP RS and explore potential causes using a novel analytical tool, the Ellipse 9. METHODS: Thirty patients undergoing eTEP RS without posterior rectus sheath closure were assessed before and 3 months after surgery using CT scan images. Key measurements analyzed included the distance between linea semilunaris (X2), eccentricity over the Cord (c/a Cord), superior eccentricity (c/a Sup), Y2, and the superior perimeter of the abdomen. The Ellipse 9 tool, which provides graphical images and numerical representations, was utilized alongside patient-reported outcomes to assess perceived abdominal changes. RESULTS: The study group exhibited a trend toward a flatter abdomen with reduced distance between linea semilunaris(X2). However, 17% of patients developed upper abdominal bulging (5). Significant differences in c/a Cord, c/a Sup, Y2, and the superior perimeter of the abdomen, confirmed with Bonferroni corrections, were noted between bulging (5 patients) and non-bulging groups (25 patients). There was a notable disparity between patient perceptions and objective outcomes. CONCLUSION: The eTEP RS procedure improved abdominal contour in most patients from a selected cohort. The Ellipse 9 tool was valuable for the objective analysis of these changes. The cause of bulging post-eTEP RS is probably multifactorial. Notably, there was often a discrepancy between patient perceptions of bulging and objective clinical findings.


Asunto(s)
Pared Abdominal , Hernia Ventral , Hernia Incisional , Laparoscopía , Humanos , Estudios Retrospectivos , Mejoramiento de la Calidad , Mallas Quirúrgicas , Músculos Abdominales/diagnóstico por imagen , Músculos Abdominales/cirugía , Hernia Ventral/diagnóstico por imagen , Hernia Ventral/cirugía , Pared Abdominal/cirugía , Herniorrafia/métodos , Hernia Incisional/cirugía , Laparoscopía/métodos
16.
J Surg Res ; 297: 18-25, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38428260

RESUMEN

INTRODUCTION: Liver transplantation (LT) is a technically complex operation and usually performed on ill patients. A major postoperative morbidity is incisional hernia, occurring in 9.5%-32.4% of cases. There are mixed results in transplant studies regarding potential risk factors. Additionally, the literature is lacking in the relationship between specific immunosuppressive induction agents administered during LT and postoperative incisional hernia. METHODS: A single center, retrospective cohort study of patients who underwent primary LT between 4/2011-1/2018 was conducted. Clinical variables including demographics and comorbidities were reviewed. The primary end point was the development of an incisional hernia following LT. Sub analysis was performed for secondary end points to determine potential risk factors, including immunosuppressive induction agent. RESULTS: Overall, 418 patients met inclusion criteria. At 5 y post-LT, there were 66/271 (24.4%) and 53/147 (36.1%) patients diagnosed with an incisional hernia in the methylprednisolone and basiliximab groups, respectively. After propensity score matching, there was no difference in incisional hernia development between induction agents, P = 0.19. For patients with body mass index ≥30 and postoperative seroma of the abdominal wall, the hazard ratios were 2.67 (95% CI = 1.7, 4.3) and 2.03 (95% CI = 1.1, 3.9), respectively. CONCLUSIONS: Incisional hernia rate after LT was 28.5% at 5 y. Our analysis found that immunosuppressive induction agent at LT was not associated with the development of postoperative incisional hernia. However, preoperative obesity (body mass index ≥30) and postoperative seroma of the abdominal wall were potential risk factors. Further studies are needed to delineate if these risk factors remain across institutions and in alternative settings.


Asunto(s)
Hernia Ventral , Hernia Incisional , Trasplante de Hígado , Humanos , Hernia Incisional/cirugía , Trasplante de Hígado/efectos adversos , Estudios Retrospectivos , Seroma/etiología , Estudios de Seguimiento , Recurrencia Local de Neoplasia/cirugía , Complicaciones Posoperatorias/etiología , Terapia de Inmunosupresión/efectos adversos , Inmunosupresores , Factores de Riesgo , Hernia Ventral/cirugía , Herniorrafia/efectos adversos
17.
Khirurgiia (Mosk) ; (3): 14-20, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38477239

RESUMEN

OBJECTIVE: To review the first robotic hernia repairs performed at the Ilyinsky Hospital, evolution of this technology, learning curve and early outcomes. MATERIAL AND METHODS: There were 17 procedures at the Ilyinskaya Hospital between 2021 and 2023 (13 men and 4 women). Mean age was 60 years, body mass index 28 kg/m2. ASA grade 1 was observed in 1 patient, grade 2 - 14 ones, grade 3 - 2 patients. Ventral, inguinal and umbilical hernias were diagnosed in 7, 8 and 2 cases, respectively. Ventral hernias required IPOM+ procedure in 3 cases, eTEP-RS procedure in 2 cases and eTEP-RS-TAR procedure in 2 cases. Patients with inguinal hernia underwent transabdominal preperitoneal hernia repair. In case of umbilical hernia, TARUP procedure was performed in 1 case and vTAPP procedure in 1 case. RESULTS: Mean surgery time was 2 hours 38 min (min 1 hour 35 min, max 10 hours 11 min). There was one intraoperative complication (bleeding from epigastric artery). The follow-up period ranged from 3 months to 3 years. There were no recurrent hernias. Postoperative complications were noted in 2 cases. One patient was diagnosed with epididymitis after TAPP, 1 patient - with seroma after eTEP-RS procedure. All complications were relieved by conservative treatment. Bleeding from a. epigastrica inferior was diagnosed after removal of the trocar at the end of surgery. This event required suturing. CONCLUSION: Robotic hernia repair appears to be technically feasible and safe. This approach provides favorable results regarding quality of life and recurrence rate.


Asunto(s)
Hernia Inguinal , Hernia Ventral , Hernia Incisional , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Hernia Inguinal/cirugía , Hernia Ventral/cirugía , Herniorrafia/métodos , Hernia Incisional/cirugía , Laparoscopía/métodos , Calidad de Vida , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Mallas Quirúrgicas , Resultado del Tratamiento
19.
Surg Endosc ; 38(4): 2019-2026, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38424284

RESUMEN

INTRODUCTION: Intraperitoneal onlay mesh (IPOM) placement for small to medium-sized hernias has garnered negative attention due to perceived long-term risk of mesh-related complications. However, sparse data exists supporting such claims after minimally invasive (MIS) IPOM repairs and most is hindered by the lack of long-term follow-up. We sought to report long-term outcomes and mesh-related complications of MIS IPOM ventral hernia repairs. METHODS AND PROCEDURES: Adult patients who underwent MIS IPOM ventral hernia repair at our institution were identified in the Abdominal Core Health Quality Collaborative database from October 2013 to October 2020. Outcomes included hernia recurrence and mesh-related complications or reoperations up to 6 years postoperatively. RESULTS: A total of 325 patients were identified. The majority (97.2%) of cases were elective, non-recurrent (74.5%), and CDC class I (99.4%). Mean hernia width was 4.16 ± 3.86 cm. Median follow-up was 3.6 (IQR 2.8-5) years. Surgeon-entered or patient-reported follow-up was available for 253 (77.8%) patients at 3 years or greater postoperatively. One patient experienced an early small bowel obstruction and was reoperated on within 30 days. Two-hundred forty-five radiographic examinations were available up to 6 years postoperatively. Twenty-seven patients had hernia recurrence on radiographic examination up to 6 years postoperatively. During long-term follow-up, two mesh-related complications required reoperations: mesh removed for chronic pain and mesh removal at the time of colon surgery for perforated cancer. Sixteen additional patients required reoperation within 6 years for the following reasons: hernia recurrence (n = 5), unrelated intraabdominal pathology (n = 9), obstructed port site hernia (n = 1), and adhesive bowel obstruction unrelated to the prosthesis (n = 1). The rate of reoperation due to intraperitoneal mesh complications was 0.62% (2/325) with up to 6 year follow-up. CONCLUSION: Intraperitoneal mesh for repair of small to medium-sized hernias has an extremely low rate of long-term mesh-related complications. It remains a safe and durable option for hernia surgeons.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Hernia Ventral , Hernia Incisional , Obstrucción Intestinal , Laparoscopía , Adulto , Humanos , Mallas Quirúrgicas/efectos adversos , Hernia Ventral/cirugía , Herniorrafia/efectos adversos , Prótesis e Implantes , Obstrucción Intestinal/cirugía , Hernia Incisional/cirugía , Recurrencia
20.
Cir Esp (Engl Ed) ; 102(5): 275-280, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38307255

RESUMEN

BACKGROUND: The aim of this study was to assess the utility of the EVEREG registry in evaluating the evolution of surgical treatment for incisional hernia and its outcomes in Spain by comparing data from 2 study periods. METHODS: A retrospective comparative analysis of hernia surgeries performed between 2011 and 2015 (first period) and between 2017 and 2022 (second period) was conducted using data collected from the EVEREG registry. RESULTS: Statistically significant differences were observed in the second cohort, including: a decrease in minimally invasive procedures (11.7% vs 8.2%; P < .001), an increase in emergency surgeries for males (31.7% vs 41.2%; P = .017), an increase in trocar hernia repairs (16% vs 26.2%; P < .0001), a reduction in suture repairs (2.8% vs 1.5%; P < .0001), and an increase in retromuscular techniques (36.4% vs 52.4%; P < .001) in open surgery with mesh. In elective surgery, there was a decrease in the average length of stay (4.9 vs 3.8 days; P < .0001), the percentage of complications (27.9% vs 24.0%; P < .0001), reoperations (3.5% vs 1.4%; P < .0001), and mortality (0.6% vs 0.2%; P = .002). Long-term outcomes included a decrease in recurrences after 12 months (20.7% vs 14.5%; P < .0001) and in chronic pain (13.7% vs 2.5%; P < .0001) and chronic infections (9.1% vs 14.5%; P < .0001) after 6 months. CONCLUSION: In recent years, there has been a significant improvement in the outcomes of incisional hernia treatment. The registry serves as a fundamental tool for assessing the evolution of hernia treatment and enables the identification of key areas for improvement and the evaluation of treatment outcomes.


Asunto(s)
Herniorrafia , Hernia Incisional , Sistema de Registros , Humanos , España/epidemiología , Masculino , Herniorrafia/métodos , Herniorrafia/estadística & datos numéricos , Femenino , Hernia Incisional/cirugía , Hernia Incisional/epidemiología , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Mallas Quirúrgicas/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento , Tiempo de Internación/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA