Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.382
Filtrar
Más filtros




Intervalo de año de publicación
1.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742736

RESUMEN

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Falla de Prótesis , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ecocardiografía Transesofágica , Masculino , Resultado del Tratamiento , Femenino , Anciano , Reoperación
2.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38742523

RESUMEN

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Masculino , Femenino , Anciano , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Italia/epidemiología , Anciano de 80 o más Años , Readmisión del Paciente/estadística & datos numéricos , Insuficiencia del Tratamiento , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía
4.
Laeknabladid ; 110(5): 247-253, 2024 May.
Artículo en Islandés | MEDLINE | ID: mdl-38713559

RESUMEN

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano , Factores de Riesgo , Estudios Retrospectivos , Islandia/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/etiología , Incidencia , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad
5.
Trials ; 25(1): 324, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755709

RESUMEN

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Asunto(s)
Válvula Aórtica , Aspirina , Bioprótesis , Inhibidores del Factor Xa , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Pirazoles , Piridonas , Ensayos Clínicos Controlados Aleatorios como Asunto , Trombosis , Humanos , Aspirina/administración & dosificación , Aspirina/uso terapéutico , Aspirina/efectos adversos , Piridonas/uso terapéutico , Piridonas/administración & dosificación , Piridonas/efectos adversos , Estudios Prospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Trombosis/prevención & control , Trombosis/etiología , Pirazoles/uso terapéutico , Pirazoles/administración & dosificación , Pirazoles/efectos adversos , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/efectos adversos , Femenino , Masculino , Persona de Mediana Edad , Factores de Tiempo , Anciano , Adulto , Fibrinolíticos/administración & dosificación , Fibrinolíticos/efectos adversos
6.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38749587

RESUMEN

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Asunto(s)
Valvuloplastia con Balón , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Cuidados Paliativos , Stents , Tetralogía de Fallot , Humanos , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Lactante , Resultado del Tratamiento , Factores de Edad , Preescolar , Niño , Adulto , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Adolescente , Recién Nacido , Adulto Joven , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Factores de Riesgo , Femenino , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Masculino , Hemodinámica , Persona de Mediana Edad , Recuperación de la Función
7.
JACC Cardiovasc Interv ; 17(8): 1060-1062, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573255
11.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38606564

RESUMEN

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Masculino , Femenino , Adolescente , Adulto Joven , Niño , Adulto , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Selección de Paciente , Toma de Decisiones Clínicas , Recuperación de la Función , Hemodinámica
12.
Inn Med (Heidelb) ; 65(5): 431-438, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38635087

RESUMEN

The pathophysiology of aortic valve diseases is of predominantly degenerative nature, characterized by calcific aortic valve stenosis, which is associated with a reduction in prognosis. The prevalence of aortic valve insufficiency also increases with advancing age. Timely causal treatment is crucial in the management of aortic valve diseases. Following the indication for intervention, the heart team plays a central role in evaluating the results and making therapeutic decisions that consider the patient's preferences. In the assessment of treatment options, considerations regarding the long-term perspective are particularly crucial, especially in younger patients. The most common therapeutic approach for aortic valve diseases is the introduction of a new valve prosthesis. In the majority of cases, this is now achieved through catheter-based implantation of a bioprosthetic heart valve, known as transcatheter aortic valve implantation (TAVI). Open surgical aortic valve replacement (AVR) is favored in younger patients with low surgical risk or in the case that TAVI is not feasible. In AVR, both biological and the longest-lasting mechanical prosthesis types are used. Surgical repair techniques are primarily applied in cases of aortic valve regurgitation. Notably, TAVI, as well as surgical procedures for the treatment of aortic valve diseases, have undergone significant advancements in recent years, including expanded indications for TAVI and, on the surgical side, in particular the development of minimally invasive surgical techniques.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Prótesis Valvulares Cardíacas , Enfermedad de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Bioprótesis
14.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639143

RESUMEN

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Asunto(s)
Técnicas de Ablación , Cateterismo Cardíaco , Cardiomiopatía Hipertrófica , Etanol , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Humanos , Estudios Retrospectivos , Masculino , Etanol/administración & dosificación , Etanol/efectos adversos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/fisiopatología , Femenino , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Persona de Mediana Edad , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Recuperación de la Función , Anciano de 80 o más Años , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad
16.
JACC Cardiovasc Interv ; 17(8): 1073-1075, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658125
18.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584521

RESUMEN

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Enfermedad Iatrogénica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ablación por Catéter/efectos adversos , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Agujas , Función Ventricular Izquierda , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Oclusión Coronaria/fisiopatología , Angiografía Coronaria
19.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597297

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Asunto(s)
Cateterismo Cardíaco , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Medición de Riesgo , Adolescente , Resultado del Tratamiento , Factores de Riesgo , Masculino , Niño , Estudios Retrospectivos , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Adulto Joven , Valor Predictivo de las Pruebas , Hemodinámica , Stents , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Toma de Decisiones Clínicas , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA