Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 681
Filtrar
1.
Sci Rep ; 14(1): 18053, 2024 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103382

RESUMEN

In this in vitro study, the use of a 445 nm diode laser was investigated for the decontamination of titanium dental implants. Different irradiation protocols and the effect of repetitive laser irradiation on temperature increase and decontamination efficacy were evaluated on titanium implant models. An automated setup was developed to realize a scanning procedure for a full surface irradiation to recapitulate a clinical treatment. Three irradiation parameter sets A (continuous wave, power 0.8 W, duty cycle (DC) 100%, and 5 s), B (pulsed mode, DC 50%, power 1.0 W, and 10 s), and C (pulsed mode, DC 10%, power 3.0 W, and 20 s) were used to treat the rods for up to ten consecutive scans. The resulting temperature increase was measured by a thermal imaging camera and the decontamination efficacy of the procedures was evaluated against Escherichia coli and Staphylococcus aureus, and correlated with the applied laser fluence. An implant's temperature increase of 10 °C was set as the limit accepted in literature to avoid thermal damage to the surrounding tissue in vivo. Repeated irradiation of the specimens resulted in a steady increase in temperature. Parameter sets A and B caused a temperature increase of 11.27 ± 0.81 °C and 9.90 ± 0.37 °C after five consecutive laser scans, respectively, while parameter set C resulted in a temperature increase of only 8.20 ± 0.53 °C after ten surface scans. The microbiological study showed that all irradiation parameter sets achieved a complete bacterial reduction (99.9999% or 6-log10) after ten consecutive scans, however only parameter set C did not exceed the temperature threshold. A 445 nm diode laser can be used to decontaminate dental titanium rods, and repeated laser irradiation of the contaminated areas increases the antimicrobial effect of the treatment; however, the correct choice of parameters is needed to provide adequate laser fluence while preventing an implant's temperature increase that could cause damage to the surrounding tissue.


Asunto(s)
Implantes Dentales , Escherichia coli , Láseres de Semiconductores , Staphylococcus aureus , Titanio , Titanio/química , Implantes Dentales/microbiología , Escherichia coli/efectos de la radiación , Staphylococcus aureus/efectos de la radiación , Descontaminación/métodos , Temperatura , Humanos , Técnicas In Vitro
2.
F1000Res ; 13: 281, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39149510

RESUMEN

Introduction: Osseointegration stands as a pivotal concept within the realm of dental implants, signifying the intricate process through which a dental implant integrates with the adjoining bone tissue. Graphene oxide (GO) has been shown to promote osseointegration, the process by which the implant fuses with the surrounding bone. The objective of this study was to assess the osseointegrative and antimicrobial properties of GO nano coated dental implants. Methods: A systematic search was conducted using electronic databases (e.g., PubMed, Scopus, Web of Science) to identify relevant studies published. Inclusion criteria encompassed studies that evaluated the effects of GO nano coating on osseointegrative and antimicrobial characteristics of dental implants. Studies not written in English and published before 2012 were excluded. Results: The initial search yielded a total of 127 potential studies, of which six met the inclusion criteria and five were included in the review. These studies provided data on GO nano coated dental implants and their osseointegrative and antimicrobial properties. All the included studies showed moderate risk of bias. None of the studies provided information related to sample size calculation or sampling technique. Discussion: The findings from the included studies demonstrated that GO nano coating had a positive impact on osseointegrative properties of dental implants. Enhanced bone-implant contact and increased bone density were observed in animals and humans receiving GO nano coated implants. Furthermore, the antimicrobial properties of GO nano coating were found to inhibit bacterial colonization and biofilm formation on the implant surface, reducing the risk of implant-associated infections. Conclusion: The findings indicate that GO nano coating holds promise in enhancing the success rate and longevity of dental implants. However, more studies with larger sample sizes, are needed to further strengthen the evidence and determine the long-term effects of GO nano coated dental implants.


Asunto(s)
Antiinfecciosos , Materiales Biocompatibles Revestidos , Implantes Dentales , Grafito , Oseointegración , Grafito/química , Grafito/farmacología , Implantes Dentales/microbiología , Oseointegración/efectos de los fármacos , Humanos , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Antiinfecciosos/farmacología , Animales , Nanoestructuras
3.
mSphere ; 9(7): e0005924, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-38980075

RESUMEN

Osseointegrated dental implants replace missing teeth and create an artificial surface for biofilms of complex microbial communities to grow. These biofilms on implants and dental surfaces can trigger infection and inflammation in the surrounding tissue. This study investigated the microbial characteristics of peri-implant mucositis (PM) and explored the correlation between microbial ecological imbalance, community function, and disease severity by comparing the submucosal microflora from PM with those of healthy inter-subject implants and intra-subject gingivitis (G) within a group of 32 individuals. We analyzed submucosal plaques from PM, healthy implant (HI), and G sites using metagenome shotgun sequencing. The bacterial diversity of HIs was higher than that of PM, according to the Simpson index. Beta diversity revealed differences in taxonomic and functional compositions across the groups. Linear discriminant analysis of the effect size identified 15 genera and 37 species as biomarkers that distinguished PM from HIs. Pathways involving cell motility and protein processing in the endoplasmic reticulum were upregulated in PM, while pathways related to the metabolism of cofactors and vitamins were downregulated. Microbial dysbiosis correlated positively with the severity of clinical inflammation measured by the sulcus bleeding index (SBI) in PM. Prevotella and protein processing in the endoplasmic reticulum also correlated positively with the SBI. Our study revealed PM's microbiological and functional traits and suggested the importance of certain functions in disease severity.IMPORTANCEPeri-implant mucositis is an early stage in the progression of peri-implantitis. The high prevalence of it has been a threat to the widespread use of implant prosthodontics. The link between the submucosal microbiome and peri-implant mucositis was demonstrated previously. Nevertheless, the taxonomic and functional composition of the peri-implant mucositis microbiome remains controversial. In this study, we comprehensively characterize the microbial signature of peri-implant mucositis and for the first time, we investigate the correlations between microbial dysbiosis, functional potential, and disease severity. With the help of metagenomic sequencing, we find the positive correlations between microbial dysbiosis, genus Prevotella, pathway of protein processing in the endoplasmic reticulum, and more severe mucosal bleeding in the peri-implant mucositis. Our studies offer insight into the pathogenesis of peri-implant mucositis by providing information on the relationships between community function and disease severity.


Asunto(s)
Bacterias , Implantes Dentales , Disbiosis , Microbiota , Humanos , Masculino , Persona de Mediana Edad , Femenino , Bacterias/clasificación , Bacterias/aislamiento & purificación , Bacterias/genética , Implantes Dentales/microbiología , Implantes Dentales/efectos adversos , Adulto , Disbiosis/microbiología , Índice de Severidad de la Enfermedad , Anciano , Gingivitis/microbiología , Periimplantitis/microbiología , Mucositis/microbiología , Estomatitis/microbiología , Estomatitis/etiología , Metagenoma , Biopelículas/crecimiento & desarrollo
4.
Clin Exp Dent Res ; 10(4): e903, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39031165

RESUMEN

OBJECTIVES: To explore the antimicrobial potential of strontium (Sr)-functionalized wafers against multiple bacteria associated with per-implant infections, in both mono- and multispecies biofilms. MATERIALS AND METHODS: The bactericidal and bacteriostatic effect of silicon wafers functionalized with a strontium titanium oxygen coating (Sr-Ti-O) or covered only with Ti (controls) against several bacteria, either grown as a mono-species or multispecies biofilms, was assessed using a bacterial viability assay and a plate counting method. Mono-species biofilms were assessed after 2 and 24 h, while the antimicrobial effect on multispecies biofilms was assessed at Days 1, 3, and 6. The impact of Sr functionalization on the total percentage of Porphyromonas gingivalis in the multispecies biofilm, using qPCR, and gingipain activity was also assessed. RESULTS: Sr-functionalized wafers, compared to controls, were associated with statistically significant less viable cells in both mono- and multispecies tests. The number of colony forming units (CFUs) within the biofilm was significantly less in Sr-functionalized wafers, compared to control wafers, for Staphylococcus aureus at all time points of evaluation and for Escherichia coli at Day 1. Gingipain activity was less in Sr-functionalized wafers, compared to control wafers, and the qPCR showed that P. gingivalis remained below detection levels at Sr-functionalized wafers, while it consisted of 15% of the total biofilm on control wafers at Day 6. CONCLUSION: Sr functionalization displayed promising antimicrobial potential, possessing bactericidal and bacteriostatic ability against bacteria associated with peri-implantitis grown either as mono-species or mixed in a multispecies consortium with several common oral microorganisms.


Asunto(s)
Biopelículas , Periimplantitis , Porphyromonas gingivalis , Estroncio , Titanio , Titanio/química , Titanio/farmacología , Biopelículas/efectos de los fármacos , Periimplantitis/microbiología , Periimplantitis/tratamiento farmacológico , Estroncio/farmacología , Porphyromonas gingivalis/efectos de los fármacos , Humanos , Antibacterianos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Viabilidad Microbiana/efectos de los fármacos , Implantes Dentales/microbiología
5.
Biomed Mater ; 19(5)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016135

RESUMEN

The performance and long-term durability of dental implants hinge on the quality of bone integration and their resistance to bacteria. This research aims to introduce a surface modification strategy for zirconia implants utilizing femtosecond laser ablation techniques, exploring their impact on osteoblast cell behavior and bacterial performance, as well as the integral factors influencing the soft tissue quality surrounding dental implants. Ultrafast lasers were employed to craft nanoscale groove geometries on zirconia surfaces, with thorough analyses conducted using x-ray diffraction, scanning electron microscopy, atomic force microscopy, and water contact angle measurements. The study evaluated the response of human fetal osteoblastic cell lines to textured zirconia ceramics by assessing alkaline phosphatase activity, collagen I, and interleukin 1ßsecretion over a 7 day period. Additionally, the antibacterial behavior of the textured surfaces was investigated usingFusobacterium nucleatum, a common culprit in infections associated with dental implants. Ciprofloxacin (CIP), a widely used antibacterial antibiotic, was loaded onto zirconia ceramic surfaces. The results of this study unveiled a substantial reduction in bacterial adhesion on textured zirconia surfaces. The fine biocompatibility of these surfaces was confirmed through the MTT assay and observations of cell morphology. Moreover, the human fetal osteoblastic cell line exhibited extensive spreading and secreted elevated levels of collagen I and interleukin 1ßin the modified samples. Drug release evaluations demonstrated sustained CIP release through a diffusion mechanism, showcasing excellent antibacterial activity against pathogenic bacteria, includingStreptococcus mutans, Pseudomonas aeruginosa, andEscherichia coli.


Asunto(s)
Antibacterianos , Cerámica , Rayos Láser , Osteoblastos , Propiedades de Superficie , Circonio , Circonio/química , Osteoblastos/citología , Osteoblastos/efectos de los fármacos , Humanos , Antibacterianos/farmacología , Antibacterianos/química , Cerámica/química , Cerámica/farmacología , Línea Celular , Implantes Dentales/microbiología , Fusobacterium nucleatum/efectos de los fármacos , Ensayo de Materiales , Ciprofloxacina/farmacología , Ciprofloxacina/química , Interleucina-1beta/metabolismo , Adhesión Bacteriana/efectos de los fármacos , Difracción de Rayos X , Microscopía Electrónica de Rastreo , Fosfatasa Alcalina/metabolismo , Microscopía de Fuerza Atómica , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología
6.
Cochrane Database Syst Rev ; 7: CD011778, 2024 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-38994711

RESUMEN

BACKGROUND: Periodontitis and peri-implant diseases are chronic inflammatory conditions occurring in the mouth. Left untreated, periodontitis progressively destroys the tooth-supporting apparatus. Peri-implant diseases occur in tissues around dental implants and are characterised by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. Treatment aims to clean the pockets around teeth or dental implants and prevent damage to surrounding soft tissue and bone, including improvement of oral hygiene, risk factor control (e.g. encouraging cessation of smoking) and surgical interventions. The key aspect of standard non-surgical treatment is the removal of the subgingival biofilm using subgingival instrumentation (SI) (also called scaling and root planing). Antimicrobial photodynamic therapy (aPDT) can be used an adjunctive treatment to SI. It uses light energy to kill micro-organisms that have been treated with a light-absorbing photosensitising agent immediately prior to aPDT. OBJECTIVES: To assess the effects of SI with adjunctive aPDT versus SI alone or with placebo aPDT for periodontitis and peri-implant diseases in adults. SEARCH METHODS: We searched the Cochrane Oral Health Trials Register, CENTRAL, MEDLINE, Embase, two other databases and two trials registers up to 14 February 2024. SELECTION CRITERIA: We included randomised controlled trials (RCTs) (both parallel-group and split-mouth design) in participants with a clinical diagnosis of periodontitis, peri-implantitis or peri-implant disease. We compared the adjunctive use of antimicrobial photodynamic therapy (aPDT), in which aPDT was given after subgingival or submucosal instrumentation (SI), versus SI alone or a combination of SI and a placebo aPDT given during the active or supportive phase of therapy. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methodological procedures, and we used GRADE to assess the certainty of the evidence. We prioritised six outcomes and the measure of change from baseline to six months after treatment: probing pocket depth (PPD), bleeding on probing (BOP), clinical attachment level (CAL), gingival recession (REC), pocket closure and adverse effects related to aPDT. We were also interested in change in bone level (for participants with peri-implantitis), and participant satisfaction and quality of life. MAIN RESULTS: We included 50 RCTs with 1407 participants. Most studies used a split-mouth study design; only 18 studies used a parallel-group design. Studies were small, ranging from 10 participants to 88. Adjunctive aPDT was given in a single session in 39 studies, in multiple sessions (between two and four sessions) in 11 studies, and one study included both single and multiple sessions. SI was given using hand or power-driven instrumentation (or both), and was carried out prior to adjunctive aPDT. Five studies used placebo aPDT in the control group and we combined these in meta-analyses with studies in which SI alone was used. All studies included high or unclear risks of bias, such as selection bias or performance bias of personnel (when SI was carried out by an operator aware of group allocation). We downgraded the certainty of all the evidence owing to these risks of bias, as well as for unexplained statistical inconsistency in the pooled effect estimates or for imprecision when evidence was derived from very few participants and confidence intervals (CI) indicated possible benefit to both intervention and control groups. Adjunctive aPDT versus SI alone during active treatment of periodontitis (44 studies) We are very uncertain whether adjunctive aPDT during active treatment of periodontitis leads to improvement in any clinical outcomes at six months when compared to SI alone: PPD (mean difference (MD) 0.52 mm, 95% CI 0.31 to 0.74; 15 studies, 452 participants), BOP (MD 5.72%, 95% CI 1.62 to 9.81; 5 studies, 171 studies), CAL (MD 0.44 mm, 95% CI 0.24 to 0.64; 13 studies, 414 participants) and REC (MD 0.00, 95% CI -0.16 to 0.16; 4 studies, 95 participants); very low-certainty evidence. Any apparent differences between adjunctive aPDT and SI alone were not judged to be clinically important. Twenty-four studies (639 participants) observed no adverse effects related to aPDT (moderate-certainty evidence). No studies reported pocket closure at six months, participant satisfaction or quality of life. Adjunctive aPDT versus SI alone during supportive treatment of periodontitis (six studies) We were very uncertain whether adjunctive aPDT during supportive treatment of periodontitis leads to improvement in any clinical outcomes at six months when compared to SI alone: PPD (MD -0.04 mm, 95% CI -0.19 to 0.10; 3 studies, 125 participants), BOP (MD 4.98%, 95% CI -2.51 to 12.46; 3 studies, 127 participants), CAL (MD 0.07 mm, 95% CI -0.26 to 0.40; 2 studies, 85 participants) and REC (MD -0.20 mm, 95% CI -0.48 to 0.08; 1 study, 24 participants); very low-certainty evidence. These findings were all imprecise and included no clinically important benefits for aPDT. Three studies (134 participants) reported adverse effects: a single participant developed an abscess, though it is not evident whether this was related to aPDT, and two studies observed no adverse effects related to aPDT (moderate-certainty evidence). No studies reported pocket closure at six months, participant satisfaction or quality of life. AUTHORS' CONCLUSIONS: Because the certainty of the evidence is very low, we cannot be sure if adjunctive aPDT leads to improved clinical outcomes during the active or supportive treatment of periodontitis; moreover, results suggest that any improvements may be too small to be clinically important. The certainty of this evidence can only be increased by the inclusion of large, well-conducted RCTs that are appropriately analysed to account for change in outcome over time or within-participant split-mouth study designs (or both). We found no studies including people with peri-implantitis, and only one study including people with peri-implant mucositis, but this very small study reported no data at six months, warranting more evidence for adjunctive aPDT in this population group.


Asunto(s)
Raspado Dental , Periimplantitis , Fotoquimioterapia , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Fotoquimioterapia/métodos , Periimplantitis/tratamiento farmacológico , Periimplantitis/terapia , Adulto , Implantes Dentales/efectos adversos , Implantes Dentales/microbiología , Fármacos Fotosensibilizantes/uso terapéutico , Periodontitis/tratamiento farmacológico , Periodontitis/microbiología , Periodontitis/terapia , Enfermedades Periodontales/tratamiento farmacológico , Terapia Combinada/métodos , Aplanamiento de la Raíz
7.
Arch Microbiol ; 206(8): 354, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017726

RESUMEN

Titanium implants are subject to bacterial adhesion and peri-implantitis induction, and biosurfactants bring a new alternative to the fight against infections. This work aimed to produce and characterize the biosurfactant from Bacillus subtilis ATCC 19,659, its anti-adhesion and antimicrobial activity, and cell viability. Anti-adhesion studies were carried out against Streptococcus sanguinis, Staphylococcus aureus, Fusobacterium nucleatum, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Proteus mirabilis as the minimum inhibitory concentration and the minimum bactericidal concentration. Cell viability was measured against osteoblast and fibroblast cells. The biosurfactant was classified as lipopeptide, with critical micelle concentration at 40 µg mL- 1, and made the titanium surface less hydrophobic. The anti-adhesion effect was observed for Staphylococcus aureus and Streptococcus sanguinis with 54% growth inhibition and presented a minimum inhibitory concentration of 15.7 µg mL- 1 for Streptococcus sanguinis and Aggregatibacter actinomycetemcomitans. The lipopeptide had no cytotoxic effect and demonstrated high potential application against bacterial biofilms.


Asunto(s)
Adhesión Bacteriana , Biopelículas , Implantes Dentales , Lipopéptidos , Pruebas de Sensibilidad Microbiana , Titanio , Titanio/farmacología , Titanio/química , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Adhesión Bacteriana/efectos de los fármacos , Implantes Dentales/microbiología , Lipopéptidos/farmacología , Humanos , Antibacterianos/farmacología , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/fisiología , Bacillus subtilis/efectos de los fármacos , Porphyromonas gingivalis/efectos de los fármacos , Porphyromonas gingivalis/fisiología , Porphyromonas gingivalis/crecimiento & desarrollo , Aggregatibacter actinomycetemcomitans/efectos de los fármacos , Propiedades de Superficie , Fibroblastos/efectos de los fármacos , Fusobacterium nucleatum/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Osteoblastos/efectos de los fármacos , Tensoactivos/farmacología
8.
Dent Mater ; 40(8): 1199-1207, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38853104

RESUMEN

INTRODUCTION: Peri-implantitis is an inflammatory process around dental implants that is characterised by bone loss that may jeopardize the long-term survival of osseo integrated dental implants. The aim of this study was to create a surface coating on titanium abutments that possesses cellular adhesion and anti-microbial properties as a post-implant placement strategy for patients at risk of peri-implantitis. MATERIALS AND METHODSMETHODS: Titanium alloy Grade V stubs were coated with gold particles and then subjected to ceramic conversion treatment (CCT) at 620 °C for 3, 8 and 80 h. The surface characteristics and chemistry were assessed using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD) analysis. The leaching profile was investigated by inductively coupled plasma mass spectroscopy (ICP-MS) for all groups after 7, 14 and 28 days in contact with distilled water. A scratch test was conducted to assess the adhesion of the gold coating to the underlying titanium discs. Two bacterial species (Staphylococcus aureus (SA) & Fusobacterium nucleatum (FN)) were used to assess the antibacterial behaviour of the coated discs using a direct attachment assay test. The potential changes in surface chemistry by the bacterial species were investigated by grazing angle XRD. RESULTS: The gold pre-coated titanium discs exhibited good stability of the coating especially after immersion in distilled water and after bacterial colonisation as evident by XRD analysis. Good surface adhesion of the coating was demonstrated for gold treated discs after scratch test analysis, especially titanium, following a 3-hour (3 H) ceramic conversion treatment. All coated discs exhibited significantly improved antimicrobial properties against both tested bacterial species compared to untreated titanium discs. CONCLUSIONS: Ceramic conversion treated titanium with a pre-deposited gold layer showed improved antimicrobial properties against both SA and FN species than untreated Ti-C discs. Scratch test analysis showed good adherence properties of the coated discs the oxide layer formed is firmly adherent to the underlying titanium substrate, suggesting that this approach may have clinical efficacy for coating implant abutments.


Asunto(s)
Cerámica , Pilares Dentales , Fusobacterium nucleatum , Oro , Microscopía Electrónica de Rastreo , Staphylococcus aureus , Propiedades de Superficie , Titanio , Difracción de Rayos X , Titanio/química , Oro/química , Fusobacterium nucleatum/efectos de los fármacos , Cerámica/química , Staphylococcus aureus/efectos de los fármacos , Ensayo de Materiales , Espectrometría por Rayos X , Periimplantitis , Implantes Dentales/microbiología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Antiinfecciosos/farmacología , Antiinfecciosos/química , Antibacterianos/farmacología , Antibacterianos/química
9.
Int J Mol Sci ; 25(11)2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38891904

RESUMEN

Tooth loss during the lifetime of an individual is common. A strategy to treat partial or complete edentulous patients is the placement of dental implants. However, dental implants are subject to bacterial colonization and biofilm formation, which cause an infection named peri-implantitis. The existing long-term treatments for peri-implantitis are generally inefficient. Thus, an electrical circuit was produced with zirconia (Zr) samples using a hot-pressing technique to impregnate silver (Ag) through channels and holes to create a path by LASER texturing. The obtained specimens were characterized according to vitro cytotoxicity, to ensure ZrAg non-toxicity. Furthermore, samples were inoculated with Staphylococcus aureus using 6.5 mA of alternating current (AC). The current was delivered using a potentiostat and the influence on the bacterial concentration was assessed. Using AC, the specimens displayed no bacterial adhesion (Log 7 reduction). The in vitro results presented in this study suggest that this kind of treatment can be an alternative and promising strategy to treat and overcome bacterial adhesion around dental implants that can evolve to biofilm.


Asunto(s)
Adhesión Bacteriana , Biopelículas , Implantes Dentales , Staphylococcus aureus , Circonio , Implantes Dentales/microbiología , Circonio/química , Biopelículas/crecimiento & desarrollo , Biopelículas/efectos de los fármacos , Humanos , Estimulación Eléctrica/métodos , Propiedades de Superficie , Periimplantitis/microbiología , Periimplantitis/terapia , Plata/química , Plata/farmacología
10.
Cell Mol Biol (Noisy-le-grand) ; 70(6): 1-6, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38836689

RESUMEN

This study aimed to investigate the antibacterial and antimicrobial activity of ozone gel against oral biofilms grown on titanium dental implant discs. The experiment used medical grade five titanium discs on which peri-implant isolated biofilms were grown. The experimental groups were control, Streptococcus mutans (S. mutans) and Granulicatella adiacens (G. adiacens), (n = 6). The oral microbes grown on titanium discs were exposed to ozone gel for 3 minutes and the antibacterial activity was assessed by turbidity test and adherence test for the antibiofilm activity test. Bacterial morphology and confluence were investigated by scanning electron microscopy (SEM), (n=3). Two bacterial species were identified from the peri-implant sample, S. mutans and G. adiacens. The results showed that adding ozone to the bacterial biofilm on titanium dental implants did not exhibit significant antibacterial activity against S. mutans. Moreover, there was no significant difference in antibiofilm activity between control and treatment groups. However, significant antibacterial and antibiofilm effect was exhibited by ozone gel against G. adiacens. Ozonated olive oil can be considered as a potential antimicrobial agent for disinfecting dental implant surfaces and treating peri-implantitis.


Asunto(s)
Biopelículas , Implantes Dentales , Aceite de Oliva , Ozono , Periimplantitis , Streptococcus mutans , Ozono/farmacología , Aceite de Oliva/farmacología , Aceite de Oliva/química , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Periimplantitis/microbiología , Periimplantitis/tratamiento farmacológico , Streptococcus mutans/efectos de los fármacos , Streptococcus mutans/fisiología , Humanos , Implantes Dentales/microbiología , Titanio/farmacología , Titanio/química , Antibacterianos/farmacología , Microscopía Electrónica de Rastreo , Pruebas de Sensibilidad Microbiana
11.
Colloids Surf B Biointerfaces ; 240: 113966, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38781846

RESUMEN

Dental Implants are expected to possess both excellent osteointegration and antibacterial activity because poor osseointegration and infection are two major causes of titanium implant failure. In this study, we constructed layer-by-layer self-assembly films consisting of anionic casein phosphopeptides-amorphous calcium phosphate (CPP-ACP) and cationic poly (L-lysine) (PLL) on sandblasted and acid etched (SLA) titanium surfaces and evaluated their osseointegration and antibacterial performance in vitro and in vivo. The surface properties were examined, including microstructure, elemental composition, wettability, and Ca2+ ion release. The impact the surfaces had on the adhesion, proliferation and differentiation abilities of MC3T3-E1 cells were investigated, as well as the material's antibacterial performance after exposure to the oral microorganisms such as Porphyromonas gingivalis (P. g) and Actinobacillus actinomycetemcomitans (A. a). For the in vivo studies, SLA and Ti (PLL/CA-3.0)10 implants were inserted into the extraction socket immediately after extracting the rabbit mandibular anterior teeth with or without exposure to mixed bacteria solution (P. g & A. a). Three rabbits in each group were sacrificed to collect samples at 2, 4, and 6 weeks of post-implantation, respectively. Radiographic and histomorphometry examinations were performed to evaluate the implant osseointegration. The modified titanium surfaces were successfully prepared and appeared as a compact nano-structure with high hydrophilicity. In particular, the Ti (PLL/CA-3.0)10 surface was able to continuously release Ca2+ ions. From the in vitro and in vivo studies, the modified titanium surfaces expressed enhanced osteogenic and antibacterial properties. Hence, the PLL/CPP-ACP multilayer coating on titanium surfaces was constructed via a layer-by-layer self-assembly technology, possibly improving the biofunctionalization of Ti-based dental implants.


Asunto(s)
Antibacterianos , Oseointegración , Polilisina , Propiedades de Superficie , Titanio , Titanio/química , Titanio/farmacología , Oseointegración/efectos de los fármacos , Animales , Polilisina/química , Polilisina/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Ratones , Implantes Dentales/microbiología , Conejos , Porphyromonas gingivalis/efectos de los fármacos , Caseínas/química , Caseínas/farmacología , Proliferación Celular/efectos de los fármacos , Aggregatibacter actinomycetemcomitans/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Adhesión Celular/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Fosfatos de Calcio
12.
Dent Mater ; 40(6): 907-920, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38714394

RESUMEN

OBJECTIVES: Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental implants is electrochemical anodization, which may generate a nanotubular surface (TiO2 nanotubes) with antibacterial potential and osteoinductive features. This systematic review and meta-analysis aims to elucidate the possible antibacterial properties of the surface in question compared to the untreated titanium surface. SOURCES: For that purpose, was performed a systematic search on the bases PubMed, Lilacs, Embase, Web Of Science, Cinahl, and Cochrane Central, as well as, manual searches and gray literature. STUDY SELECTION: The searches resulted in 742 articles, of which 156 followed for full-text reading. Then, 37 were included in the systematic review and 8 were included in meta-analysis. RESULTS: Fifteen studies revealed significant antibacterial protection using TiO2 nanotube surfaces, while 15 studies found no statistical difference between control and nanotextured surfaces. Meta-analysis of in vitro studies demonstrated relevant bacterial reduction only for studies investigating Staphylococcus aureus in a period of 6 h. Meta-analysis of in vivo studies revealed three times lower bacterial adhesion and proliferation on TiO2 nanotube surfaces. CONCLUSIONS: TiO2 nanotube topography as a surface for dental implants in preclinical research has demonstrated a positive relationship with antibacterial properties, nevertheless, factors such as anodization protocols, bacteria strains, and mono-culture methods should be taken into consideration, consequently, further studies are necessary to promote clinical translatability.


Asunto(s)
Antibacterianos , Implantes Dentales , Nanotubos , Propiedades de Superficie , Titanio , Titanio/química , Nanotubos/química , Implantes Dentales/microbiología , Antibacterianos/farmacología , Antibacterianos/química , Adhesión Bacteriana/efectos de los fármacos , Humanos , Staphylococcus aureus/efectos de los fármacos
13.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741081

RESUMEN

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Asunto(s)
Biopelículas , Implantes Dentales , Gases em Plasma , Propiedades de Superficie , Titanio , Biopelículas/efectos de los fármacos , Titanio/química , Implantes Dentales/microbiología , Pulido Dental/métodos , Glicina , Humanos , Técnicas In Vitro , Microscopía Electrónica de Rastreo , Níquel
14.
Arch Oral Biol ; 164: 105986, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38723421

RESUMEN

AIM: To evaluate the adhesion of mono and duospecies biofilm on a commercially available dental implant surface coated with hydroxyapatite nanoparticles (nanoHA). MATERIAL AND METHODS: Titanium discs were divided into two groups: double acid-etched (AE) and AE coated with nanoHA (NanoHA). Surface characteristics evaluated were morphology, topography, and wettability. Mono and duospecies biofilms of Streptococcus sanguinis (S. sanguinis) and Candida albicans (C. albicans) were formed. Discs were exposed to fetal bovine serum (FBS) to form the pellicle. Biofilm was growth in RPMI1640 medium with 10% FBS and 10% BHI medium for 6 h. Microbial viability was evaluated using colony-forming unit and metabolic activity by a colorimetric assay of the tetrazolium salt XTT. Biofilm architecture and organization were evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). RESULTS: AE surface had more pores, while NanoHA had even nanoHA crystals distribution. Roughness was similar (AE: 0.59 ± 0.07 µm, NanoHA: 0.69 ± 0.18 µm), but wettability was different (AE: Θw= 81.79 ± 8.55°, NanoHA: Θw= 53.26 ± 11.86°; P = 0.01). NanoHA had lower S. sanguinis viability in monospecies biofilm (P = 0.007). Metabolic activity was similar among all biofilms. In SEM both surfaces on C. albicans biofilm show a similar distribution of hyphae in mono and duospecies biofilms. AE surface has more S. sanguinis than the NanoHA surface in the duospecies biofilm. CLSM showed a large proportion of live cells in all groups. CONCLUSIONS: The nanoHA surface reduced the adhesion of S. sanguinis biofilm but did not alter the adhesion of C. albicans or the biofilm formed by both species.


Asunto(s)
Biopelículas , Candida albicans , Implantes Dentales , Durapatita , Microscopía Confocal , Microscopía Electrónica de Rastreo , Nanopartículas , Streptococcus sanguis , Propiedades de Superficie , Titanio , Titanio/química , Titanio/farmacología , Candida albicans/efectos de los fármacos , Candida albicans/fisiología , Biopelículas/efectos de los fármacos , Durapatita/farmacología , Durapatita/química , Streptococcus sanguis/efectos de los fármacos , Nanopartículas/química , Implantes Dentales/microbiología , Técnicas In Vitro , Adhesión Bacteriana/efectos de los fármacos , Humectabilidad , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Grabado Ácido Dental , Viabilidad Microbiana/efectos de los fármacos
15.
J. oral res. (Impresa) ; 13(1): 26-36, mayo 29, 2024. ilus
Artículo en Inglés | LILACS | ID: biblio-1563171

RESUMEN

Introduction: Microorganism infiltration through the im-plant-abutment interface causes oral health problems such as periimplantitis, leading to implant loss. Materials and Methods: A feasible new method to quantify the Streptococcus mutans (S. mutans) infiltration through the implant-abutment interface gap is introduced in the present work. Internal hexagon (IH; n = 10), external hexagon (EH; n = 10), Morse taper (MT; n = 10), and a control for each group (n = 1) were tested. Bacteria suspension was prepared at 1.5x108 CFU/mL (CFU: colony forming units), and the implants were individually submerged up to the connection level, allowing the bacteria to contact it. The abutment was removed, and bacteria count was performed. Results: The implant sets were tested under normal bacterial growth and early and late biofilm growth conditions. Colony-forming units per mL were obtained, and the results were compared among groups. Differences in bacterial count between the MT and EH (p<0.001) and the MT and IH (p<0.001) groups were significantly higher in the MT-type implant. There was a significant increment of bacterial infiltration in the MTs submitted to late biofilm growth conditions. EH and IH connections are more effective in preventing bacterial infiltration independent of the growth condition. Conclusions: The proposed methodology is feasible to evaluate the infiltration of microorganisms through the implant-abutment interface.


Introducción: La infiltración de microorganismos a través de la interfaz implante-pilar provoca problemas de salud bucal como la periimplantitis, que conduce a la pérdida del implante. Materiales y Métodos: En el presente trabajo se presenta un nuevo método factible para cuantificar la infiltración de Streptococcus mutans (S. mutans) a través de la brecha de la interfaz implante-pilar. Se probaron el hexágono interno (IH; n = 10), el hexágono externo (EH; n = 10), el cono Morse (MT; n = 10) y un control para cada grupo (n = 1). Se preparó una suspensión de bacterias a 1,5x108 UFC/mL y los implantes se sumergieron individualmente hasta el nivel de conexión, permitiendo que las bacterias entraran en contacto con él. Resultados: Se retiró el pilar y se realizó recuento de bacterias. Los conjuntos de implantes se probaron en condiciones de crecimiento bacteriano normal y de crecimiento temprano y tardío de biopelículas. Se obtuvieron unidades formadoras de colonias por ml y los resultados se compararon entre grupos. Las diferencias en el recuento bacteriano entre los grupos MT y EH (p<0,001) y MT e IH (p<0,001) fueron significativamente mayores en el implante tipo MT. Hubo un incremento significativo de la infiltración bacteriana en los MT sometidos a condiciones tardías de crecimiento de biopelículas. Las conexiones EH e IH son más efectivas para prevenir la infiltración bacteriana independientemente de las condiciones de crecimiento. Conclusión: La metodología propuesta es factible para evaluar la infiltración de microorganismos a través de la interfaz implante-pilar.


Asunto(s)
Humanos , Implantes Dentales/microbiología , Pilares Dentales/microbiología , Filtración Dental/microbiología , Filtración Dental/prevención & control , Streptococcus mutans/aislamiento & purificación , Bacterias , Biopelículas
16.
J Dent Res ; 103(5): 516-525, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38581213

RESUMEN

Titanium (Ti)-based biomaterials lack inherent antimicrobial activities, and the dental plaque formed on the implant surface is one of the main risk factors for implant infections. Construction of an antibacterial surface can effectively prevent implant infections and enhance implant success. Silver nanoparticles (AgNPs) exhibit broad antibacterial activity and a low tendency to induce drug resistance, but AgNPs easily self-aggregate in the aqueous environment, which significantly impairs their antibacterial activity. In this study, UiO-66/AgNP (U/A) nanocomposite was prepared, where zirconium metal-organic frameworks (UiO-66) were employed as the confinement matrix to control the particle size and prevent aggregation of AgNPs. The bactericidal activity of U/A against methicillin-resistant Staphylococcus aureus and Escherichia coli increased nearly 75.51 and 484.50 times compared with individually synthesized Ag. The antibacterial mechanism can be attributed to the enhanced membrane rupture caused by the ultrafine AgNPs on UiO-66, leading to protein leakage and generation of intracellular reactive oxygen species. Then, U/A was loaded onto Ti substrates (Ti-U/A) by using self-assembly deposition methods to construct an antibacterial surface coating. Ti-U/A exhibited excellent antibacterial activities and desired biocompatibility both in vitro and in vivo. The U/A nanocomposite coating technique is thus expected to be used as a promising surface modification strategy for Ti-based dental implants for preventing dental implant infections.


Asunto(s)
Antibacterianos , Materiales Biocompatibles Revestidos , Implantes Dentales , Escherichia coli , Nanopartículas del Metal , Staphylococcus aureus Resistente a Meticilina , Plata , Circonio , Plata/farmacología , Implantes Dentales/microbiología , Antibacterianos/farmacología , Nanopartículas del Metal/uso terapéutico , Escherichia coli/efectos de los fármacos , Circonio/química , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Estructuras Metalorgánicas/farmacología , Estructuras Metalorgánicas/química , Animales , Titanio/química , Nanocompuestos/química , Propiedades de Superficie , Ratones , Especies Reactivas de Oxígeno
17.
J Nanobiotechnology ; 22(1): 207, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664778

RESUMEN

Several studies suggest that oral pathogenic biofilms cause persistent oral infections. Among these is periodontitis, a prevalent condition brought on by plaque biofilm. It can even result in tooth loss. Furthermore, the accumulation of germs around a dental implant may lead to peri-implantitis, which damages the surrounding bone and gum tissue. Furthermore, bacterial biofilm contamination on the implant causes soft tissue irritation and adjacent bone resorption, severely compromising dental health. On decontaminated implant surfaces, however, re-osseointegration cannot be induced by standard biofilm removal techniques such as mechanical cleaning and antiseptic treatment. A family of nanoparticles known as nanozymes (NZs) comprise highly catalytically active multivalent metal components. The most often employed NZs with antibacterial activity are those that have peroxidase (POD) activity, among other types of NZs. Since NZs are less expensive, more easily produced, and more stable than natural enzymes, they hold great promise for use in various applications, including treating microbial infections. NZs have significantly contributed to studying implant success rates and periodontal health maintenance in periodontics and implantology. An extensive analysis of the research on various NZs and their applications in managing oral health conditions, including dental caries, dental pulp disorders, oral ulcers, peri-implantitis, and bacterial infections of the mouth. To combat bacteria, this review concentrates on NZs that imitate the activity of enzymes in implantology and periodontology. With a view to the future, there are several ways that NZs might be used to treat dental disorders antibacterially.


Asunto(s)
Antibacterianos , Biopelículas , Implantes Dentales , Periimplantitis , Periodontitis , Periimplantitis/tratamiento farmacológico , Periimplantitis/microbiología , Humanos , Periodontitis/tratamiento farmacológico , Periodontitis/microbiología , Antibacterianos/farmacología , Antibacterianos/química , Antibacterianos/uso terapéutico , Biopelículas/efectos de los fármacos , Implantes Dentales/microbiología , Animales , Nanopartículas/química , Bacterias/efectos de los fármacos
18.
Clin Exp Dent Res ; 10(1): e839, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38345466

RESUMEN

OBJECTIVE: To assess which decontamination method(s) used for the debridement of titanium surfaces (disks and dental implants) contaminated with bacterial, most efficiently eliminate bacterial biofilms. MATERIAL AND METHODS: A systematic search was conducted in four electronic databases between January 1, 2010 and October 31, 2022. The search strategy followed the PICOS format and included only in vitro studies completed on either dental implant or titanium disk samples. The assessed outcome variable consisted of the most effective method(s)-chemical or mechanical- removing bacterial biofilm from titanium surfaces. A meta-analysis was conducted, and data was summarized through single- and multi-level random effects model (p < .05). RESULTS: The initial search resulted in 5260 articles after the removal of duplicates. After assessment by title, abstract, and full-text review, a total of 13 articles met the inclusion criteria for this review. Different decontamination methods were assessed, including both mechanical and chemical, with the most common method across studies being chlorhexidine (CHX). Significant heterogeneity was noted across the included studies. The meta-analyses only identified a significant difference in biofilm reduction when CHX treatment was compared against PBS. The remaining comparisons did not identify significant differences between the various decontamination methods. CONCLUSIONS: The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.


Asunto(s)
Biopelículas , Descontaminación , Implantes Dentales , Periimplantitis , Titanio , Humanos , Implantes Dentales/microbiología , Descontaminación/métodos , Periimplantitis/microbiología , Biopelículas/efectos de los fármacos , Titanio/química , Propiedades de Superficie , Clorhexidina/farmacología , Clorhexidina/uso terapéutico
19.
BMC Oral Health ; 24(1): 105, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38233815

RESUMEN

BACKGROUND: Peri-implantitis is a polybacterial infection that can lead to the failure of dental implant rehabilitation. This study aimed to profile the microbiome of the peri-implant plaque and estimate the effect of periodontitis on it among 40 Chinese participants with dental implant prostheses and presenting with varying peri-implant and periodontal health states. METHODS: Submucosal plaque samples were collected from four distinct clinical categories based on both their implant and periodontal health status at sampling point. Clinical examinations of dental implant and remaining teeth were carried out. Metagenomic analysis was then performed. RESULTS: The microbiome of the peri-implantitis sites differed from that of healthy implant sites, both taxonomically and functionally. Moreover, the predominant species in peri-implantitis sites were slightly affected by the presence of periodontitis. T. forsythia, P. gingivalis, T. denticola, and P. endodontalis were consistently associated with peri-implantitis and inflammatory clinical parameters regardless of the presence of periodontitis. Prevotella spp. and P. endodontalis showed significant differences in the peri-implantitis cohorts under different periodontal conditions. The most distinguishing function between diseased and healthy implants is related to flagellar assembly, which plays an important role in epithelial cell invasion. CONCLUSIONS: The composition of the peri-implant microbiome varied in the diseased and healthy states of implants and is affected by individual periodontal conditions. Based on their correlations with clinical parameters, certain species are associated with disease and healthy implants. Flagellar assembly may play a vital role in the process of peri-implantitis.


Asunto(s)
Implantes Dentales , Placa Dental , Microbiota , Periimplantitis , Enfermedades Periodontales , Periodontitis , Humanos , Periimplantitis/microbiología , Implantes Dentales/microbiología , Estudios Transversales , Placa Dental/microbiología
20.
J Clin Periodontol ; 51(2): 209-221, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37941050

RESUMEN

AIM: To compare individuals with a periodontitis background (Grade C, stage III/IV-formerly generalized aggressive periodontitis) (H-GAP) with periodontally healthy subjects (H-Health) in terms of molecular changes (immunological/microbiological) accompanying experimental peri-implant mucositis and gingivitis. MATERIALS AND METHODS: H-GAP and control (H-Health) subjects were recruited, and experimental mucositis/gingivitis was induced around a single screw-retained implant and one contralateral tooth. Participants refrained from oral hygiene for 21 days in the selected areas, followed by professional prophylaxis and hygiene instructions for 21 days. Clinical parameters, immunological markers (multiplex analysis) and microbial data (16S rRNA gene sequencing) were collected at baseline, during induction (7, 14 and 21 days) and following remission (42 days). RESULTS: Clinically, no significant differences were observed between the groups (n = 10/each group) (H-GAP vs. H-Health) (p > .05, Mann-Whitney test) and the type of site (tooth vs. implant) (p > .05, Wilcoxon test) at the time of onset and resolution, or severity of gingival/mucosal inflammation. H-GAP displayed lower concentrations of the cytokines interleukin (IL)-1B, IL-4, IL-17, tumor necrosis factor-α and interferon-γ around implants than H-Health at baseline and during induction of mucositis (p < .05, Mann-Whitney test). In both groups, implants showed significantly higher inflammatory background at baseline and all subsequent visits when compared with teeth (p < .05, Wilcoxon test). Alpha and ß-diversity metrics showed a significant shift in the microbiome composition and abundances of core species during induction and resolution of peri-implant mucositis and gingivitis (p < .05, restricted maximum likelihood method of Shannon and Bray-Curtis indices, respectively). Differences were not significant for these parameters between the H-Health and H-GAP groups when the periodontal and peri-implant microbiomes were compared separately; however, at each time point, the peri-implant microbiome differed significantly from the periodontal microbiome. CONCLUSIONS: Within the limitations of this pilot study (e.g. low power), it can be concluded that different microbial shifts contribute to the onset and progression of inflammatory responses around teeth and implants and that history of periodontal disease experience plays an additional role in modulating the immune response of peri-implant and periodontal tissues to biofilm accumulation.


Asunto(s)
Periodontitis Agresiva , Implantes Dentales , Gingivitis , Mucositis , Periimplantitis , Humanos , Mucositis/etiología , Proyectos Piloto , ARN Ribosómico 16S/genética , Implantes Dentales/efectos adversos , Implantes Dentales/microbiología , Periimplantitis/microbiología , Gingivitis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA